1
|
Mitsutake R, Tanino H, Ito H. The effect of range of motion simulated with a patient-specific three-dimensional simulation analysis on dislocation after total hip arthroplasty. Hip Int 2023; 33:313-322. [PMID: 34538126 DOI: 10.1177/11207000211044807] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND Dislocation continues to be a common complication following total hip arthroplasty (THA). Although previous studies of computed simulation analysis investigated the range of motion (ROM), it is unclear whether the ROM before impingement simulated using computed tomography-based 3-dimensional simulation analysis (simulated ROM) is related to dislocation after THA. It is also unclear what angles are required in computed simulation analyses for stable hips after THA. In this study, we compared the simulated ROM in patients with and without dislocation. METHODS 16 patients with posterior dislocation were compared with 48 matched patients without dislocation. Risk factors including preoperative bone morphology of the hip, implant position, change of femoral offset, change of leg length, anterior aspect of the greater trochanter (GTa) length, and anterior inferior iliac spine length were also compared. RESULTS The mean flexion angle, internal-rotation at 90° flexion (IR) angle, cup anteversion based on the anterior pelvic plane (APP), tilt-adjusted cup anteversion and GTa length were significantly different between patients with dislocation and patients without dislocation (p = 0.033, 0.002, 0.010, 0.047, 0.046). A receiver-operating characteristic curve analysis suggested cutoff points for flexion angle, IR angle, cup anteversion based on the APP, tilt-adjusted cup anteversion and GTa length, of 114.5°, 45.5°, 19.5°, 12.0° and 15.3 mm. CONCLUSIONS This study suggests that preoperative planning to achieve a larger simulated ROM, flexion angle and IR angle, may reduce the risk of posterior dislocation. This study also suggests that fine-tuning of cup anteversion and/or trimming of the overhanging GTa during preoperative planning may reduce the risk of posterior dislocation.
Collapse
Affiliation(s)
- Ryo Mitsutake
- Department of Orthopaedic Surgery, Asahikawa Medical University, Asahikawa, Hokkaido, Japan
| | - Hiromasa Tanino
- Department of Orthopaedic Surgery, Asahikawa Medical University, Asahikawa, Hokkaido, Japan
| | - Hiroshi Ito
- Department of Orthopaedic Surgery, Asahikawa Medical University, Asahikawa, Hokkaido, Japan
| |
Collapse
|
2
|
ÇATALTEPE A. The length of distal skin incision of the postero-lateral approach affects the cup inclination during the total hip arthroplasty. JOURNAL OF HEALTH SCIENCES AND MEDICINE 2022. [DOI: 10.32322/jhsm.1071852] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
Aim: The primary aim of the study was to determine whether the length of the distal skin incision of the posterolateral approach affects the cup inclination during total hip arthroplasty (THA).
Material and Method: In this study, a cohort of 71 consecutive patients who performed between January 2017 and December 2021 with unilateral THA using a posterolateral approach was retrospectively assessed. Two groups were formed according to acetabular cup inclination with normal anteversion angle. There were 56 hips in the inside group and 17 in the outside group. A curvilinear skin incision of around 13 cm was performed. Component position evaluation was carried out through a radiographic assessment of the acetabular component on an anteroposterior pelvis radiograph. The rate of an outlier was compared between groups according to the safe zone defined as 30° to 50° of inclination and 5° to 25° of anteversion, which was described by Lewinnek et al.
Results: No significant difference in the average total incision length was found between the two groups (p=0.207). While the average distal incision length was 7.91±0.62 cm (range, 6.8-9 cm) in the inside group and 6.37±0.21 cm (range, 6-6.7 cm) in the outside group. According to ROC analysis, a patient with ≤6.7 cm of the distal length of incision (DLI) was 5.71 times more likely to be outside than a patient with >6.7 cm of DLI. Seventeen hips (23.3%) were found outside the safe range. Substantial differences were observed regarding radiographic cup inclination between the two groups (p=0.0001). In the inside group, the average cup inclination was 44.11°±3.44° (range, 37°-50°), whereas, in the outside group, it was 55.41°±2.5° (range, 52°-59°). However, there were no significant differences in the average radiographic cup anteversion between the two groups (p=0.960). Although 11 of 17 (64.5%) patients were classified as obese (BMI ≥30) in the outside group experienced higher rates of inaccurate cup orientation, logistic regression analysis showed that the individual effects of obesity on the occurrence of the inaccurate cup position were not observed (p=0.884). One posterior hip dislocation occurred after one month postoperative in the outside group.
Conclusions: Longer distal portion of the skin incision of the posterolateral approach should be performed to achieve optimal operative inclination angles of the acetabular cup during THA. The surgeon must have no hesitation in extending the distal skin incision when adopting the posterolateral approach.
Collapse
|
3
|
Yang J, Bryan AJ, Drabchuk R, Tetreault MW, Calkins TE, Della Valle CJ. Use of a monoblock dual-mobility acetabular component in primary total hip arthroplasty in patients at high risk of dislocation. Hip Int 2022; 32:648-655. [PMID: 33566709 DOI: 10.1177/1120700020988469] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION Dislocation is amongst the most common complications following total hip arthroplasty (THA). Dual-mobility bearings have been suggested as one way to reduce the risk of dislocation, particularly among patients at increased risk. The purpose of this study was to determine the outcomes of a monoblock dual-mobility shell for patients at high risk for dislocation following primary THA. METHODS A total of 155 primary THAs with a monoblock, cementless dual-mobility acetabular component were performed in patients at high risk for dislocation. Two patients died prior to their two-year follow-up. The remaining 153 THAs were followed for a mean of 5.1 years (range: 2.1 to 9.3). RESULTS There were no dislocations; however, four patients underwent revision surgery: one for an early periprosthetic acetabular fracture, one for an early periprosthetic femoral fracture, one for a late periprosthetic femoral fracture, and one for leg-length discrepancy. Intraoperative complications included one periprosthetic acetabular fracture treated with protected weight-bearing and one intraoperative proximal femoral fracture treated with cerclage wiring. Harris Hip Scores improved from a mean of 42.4 points preoperatively to a mean of 82.4 points postoperatively (p < 0.001). No cups were radiographically loose. At a mean follow-up of 5.1 years, survivorship of the acetabular component was 99.3% (95% CI, 98.1-100%) and survivorship without any reoperation was 97.4% (95% CI, 95.9-100%). DISCUSSION Although there were no dislocations in this high-risk population, periprosthetic fractures of the femur and acetabulum were common with the implants utilised.
Collapse
Affiliation(s)
- JaeWon Yang
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Andrew J Bryan
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Roman Drabchuk
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Matthew W Tetreault
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Tyler E Calkins
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Craig J Della Valle
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| |
Collapse
|
4
|
Letissier H, Barbier A, Tristan L, Dubrana F, Lefèvre C, Clavé A. Long-term survival of the Lefèvre retentive cup: 12-year follow-up analysis of 466 consecutive cases. Orthop Traumatol Surg Res 2022; 108:103173. [PMID: 34896581 DOI: 10.1016/j.otsr.2021.103173] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/12/2020] [Revised: 02/26/2021] [Accepted: 03/02/2021] [Indexed: 02/03/2023]
Abstract
INTRODUCTION The Lefèvre retentive cup is a salvage solution for total hip replacement at high risk of dislocation. Only a few studies have reported the medium or long-term survival; most often, only a small number of patients were included in these studies. This led us to conduct a retrospective analysis of a large population to determine: 1) the 10-year survival rate after primary or revision arthroplasty, 2) the complication rate. HYPOTHESIS The dislocation rate is<5% for revision arthroplasty and<2% for primary arthroplasty. MATERIAL AND METHODS This single-center retrospective study included 466 consecutive total hip replacements performed with the Lefèvre retentive cup with a 12-year theoretical minimum follow-up (1/1/1998 to 31/8/2006). There were 257 indications for primary arthroplasty and 209 for revision arthroplasty. The cohort had 316 women and the mean age at surgery was 72.9years (30.2-89.9). The mean follow-up was 10.2±5 years (0.1-19.3). A statistical analysis was done based on the Kaplan-Meier survival curves in two subsets of patients: primary and revision surgery. RESULTS At the final review, 264 patients had died because of reasons unrelated to the procedures (mean 7.8±4.7years after the procedure), 48 were lost to follow-up (mean 3.0±3.3years after the procedure), and 39 patients (8%) had undergone acetabular revision of which 12 were for infection (2.5%), 25 were for loosening (5.4%) (5 femoral loosening only) and 2 were for dislocation (0.4%). In all, there were 10/466 dislocations (2.1%) of which 5/257 (1.9%) were in the primary group and 5/209 (2.4%) were in the revision group: 2 had a cup exchange and 8 were reduced by closed procedures. The probability of survival free of mechanical complications at 10years was estimated at 94.8%±1.6% (95% CI: 91.6%-98.0%) for the primary group and 87.8%±2.7% (95% CI: 82.4%-93.2%) for the revision groups (p=0.0017). There were 39 re-operations in the overall cohort: 1/257 (0.4%) for dislocation, 7/257 (2.7%) for aseptic loosening and 3/257 (1.2%) for infection in the primary group, while in the revision group, 1/209 (0.5%) was for dislocation, 18/209 (8.6%) for aseptic loosening and 9/209 (4.3%) for infection. CONCLUSION The Lefèvre retentive cup has good long-term survival with a low mechanical complication rate, both in primary and revision surgery. To us, this implant appears to be a reliable salvage procedure for total hip replacement in patients at high risk for dislocation. LEVEL OF EVIDENCE IV; retrospective study without control group.
Collapse
Affiliation(s)
- Hoel Letissier
- Service de chirurgie orthopédique et traumatologique, CHRU de la cavale blanche, 29200 Brest, France; Laboratoire de traitement de l'information médicale (LaTIM, UMR1101), bâtiment IBRBS, 22, avenue Camille-Desmoulins, 29200 Brest, France.
| | - Aurélien Barbier
- Service de chirurgie orthopédique et traumatologique, CHRU de la cavale blanche, 29200 Brest, France
| | - Ludovic Tristan
- Service de chirurgie irthopédique, clinique du Ter, 5, allée de la clinique du Ter, 56270 Ploemeur, France
| | - Frédéric Dubrana
- Service de chirurgie orthopédique et traumatologique, CHRU de la cavale blanche, 29200 Brest, France
| | - Christian Lefèvre
- Service de chirurgie orthopédique et traumatologique, CHRU de la cavale blanche, 29200 Brest, France; Laboratoire de traitement de l'information médicale (LaTIM, UMR1101), bâtiment IBRBS, 22, avenue Camille-Desmoulins, 29200 Brest, France
| | - Arnaud Clavé
- Laboratoire de traitement de l'information médicale (LaTIM, UMR1101), bâtiment IBRBS, 22, avenue Camille-Desmoulins, 29200 Brest, France; Service de chirurgie orthopédique, polyclinique Saint-George, 2, avenue de Rimiez, 06105 Nice, France
| |
Collapse
|
5
|
Muellner M, Becker L, Wang Z, Hu Z, Hardt S, Pumberger M, Haffer H. Spinopelvic mobility is influenced by pre-existing contralateral hip arthroplasty: a matched-pair analysis in patients undergoing hip replacement. J Orthop Surg Res 2022; 17:64. [PMID: 35109897 PMCID: PMC8812232 DOI: 10.1186/s13018-022-02945-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/04/2021] [Accepted: 01/21/2022] [Indexed: 01/06/2023] Open
Abstract
Background Spinopelvic mobility gained increased attention as a contributing factor for total hip arthroplasty (THA) instability. However, it is unknown how a pre-existing THA affects spinopelvic mobility. Therefore, a propensity-score-matched analysis of primary THA patients comparing the individual segments of spinopelvic mobility between patients with pre-existing THA and no-existing THA was conducted. Consequently, the study aimed to discuss (1) whether patients with a pre-existing THA have altered spinopelvic mobility compared to the control group and (2) if spinopelvic mobility changes after THA. Methods A prospective observational study enrolled 197 elective primary THA patients, including N = 44 patients with a pre-existing unilateral THA. Using propensity-score matching adapted for age, sex, and BMI, N = 44 patients without a pre-existing THA were determined. The patients received stereoradiography in standing and relaxed sitting position pre- and postoperatively. Assessed parameters were lumbar lordosis (LL), pelvic tilt (PT), and pelvic femoral angle (PFA). Key parameters of the spinopelvic mobility were defined as lumbar flexibility (∆LL = LLstanding − LLsitting), pelvic mobility (∆PT = PTstanding − PTsitting) and hip motion (∆PFA = PFAstanding − PFAsitting). Pelvic mobility was classified as stiff (∆PT < 10°), normal (∆PT ≥ 10°–30°) and hypermobile (∆PT > 30°). The Wilcoxon rank sum test for dependent samples was used. Results Pelvic mobility was significantly increased in the pre-existing THA group (∆PT 18.2° ± 10.7) compared to the control group (∆PT 7.7° ± 8.0; p < 0.001) preoperatively and postoperatively (pre-existing: 22.2° ± 9.3; control: 17.0° ± 9.2, p = 0.022). Lumbar flexibility was significantly increased in the pre-existing THA group (∆LL 21.6° ± 11.8) compared to the control group (∆LL 12.4° ± 7.8; p < 0.001) preoperatively and postoperatively (pre-existing: 25.7° ± 11.0; control: 19.0° ± 10.2; p = 0.011). The contribution of stiff pelvic mobility is distinctly smaller in the pre-existing THA group (25%) than in the control group (75%) preoperatively. Conclusions Pre-existing THA is associated with significantly enhanced pelvic mobility and lumbar flexibility. Accordingly, we identified the patients without a pre-existing THA as risk candidates with higher likelihood for pathological spinopelvic mobility. This information will assist arthroplasty surgeons in deciding which THA candidates require preoperative radiological screening for pathologic spinopelvic mobility. Level of evidence Level II prospective cohort study. Supplementary Information The online version contains supplementary material available at 10.1186/s13018-022-02945-5.
Collapse
Affiliation(s)
- Maximilian Muellner
- Center for Musculoskeletal Surgery, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany, Berlin, Germany
| | - Luis Becker
- Center for Musculoskeletal Surgery, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany, Berlin, Germany
| | - Zhen Wang
- Center for Musculoskeletal Surgery, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany, Berlin, Germany
| | - Zhouyang Hu
- Center for Musculoskeletal Surgery, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany, Berlin, Germany
| | - Sebastian Hardt
- Center for Musculoskeletal Surgery, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany, Berlin, Germany
| | - Matthias Pumberger
- Center for Musculoskeletal Surgery, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany, Berlin, Germany
| | - Henryk Haffer
- Center for Musculoskeletal Surgery, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany, Berlin, Germany.
| |
Collapse
|
6
|
Kunze KN, Premkumar A, Bovonratwet P, Sculco PK. Acetabular Component and Liner Selection for the Prevention of Dislocation After Primary Total Hip Arthroplasty. JBJS Rev 2021; 9:01874474-202112000-00004. [PMID: 34910697 DOI: 10.2106/jbjs.rvw.21.00148] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
» Primary total hip arthroplasty (THA) is a reproducible and efficacious procedure for patients with end-stage osteoarthritis; however, dislocation remains the most common cause of revision arthroplasty. » Technological advancements in acetabular component design and liner options, in conjunction with a more comprehensive understanding of the spinopelvic factors that influence dislocation, will likely reduce the risk of dislocation and revision over time. » The contemporary liner and shell options for primary THA, in order of increasing constraint and stability, include (1) neutral, (2) lateralized, (3) face-changing (oblique), (4) lipped (high-wall) with or without lateralization, (5) modular and anatomic dual-mobility, and (6) constrained options. » Different liner designs can alter functional anteversion, inclination, and jump distance, and can be used to minimize a single predictable dislocation vector (lipped [high-wall] liners) or multiple vectors of instability risk when the dislocation direction is unpredictable (dual-mobility liners). » Liner selection should be based on the patient-specific risk of dislocation, including static anatomic (e.g., large anterior inferior iliac spine or greater trochanter morphology), dynamic anatomic (e.g., limited sitting-standing change in the sacral slope), and demographic or medical (e.g., neurocognitive disorders and obesity) risk factors.
Collapse
Affiliation(s)
- Kyle N Kunze
- Department of Orthopedic Surgery, Hospital for Special Surgery, New York, NY
| | | | | | | |
Collapse
|
7
|
Burzyński S, Sabik A, Witkowski W, Łuczkiewicz P. Influence of the femoral offset on the muscles passive resistance in total hip arthroplasty. PLoS One 2021; 16:e0250397. [PMID: 33945554 PMCID: PMC8096111 DOI: 10.1371/journal.pone.0250397] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2020] [Accepted: 04/06/2021] [Indexed: 11/18/2022] Open
Abstract
BACKGROUND Soft tissue tension is treated as a crucial factor influencing the post-THA dislocation. The femoral offset is regarded as one of the major parameters responsible for the stabilization of the prosthesis. It is unclear which soft tissue is mostly affected by the offset changes. METHODS A finite element model of the hip was created. The model comprised muscles, bones, a stem, the acetabular component and a liner. The muscles were modelled as a Hill-type musculo-tendon nonlinear springs. Nonlinear analyses of the hip flexion and internal rotation were performed for the two values of the femoral stem offset. RESULTS We observed that the quadratus femoris and gluteus medius produce the largest resisting moment opposing the external load excreted by the surgeon during the intraoperative hip dislocation test. CONCLUSIONS An increased femoral offset increases the stretching of the quadratus femoris muscle significantly and provides the growth of its initial passive force. This muscle serves as a stiff band, providing stabilisation of the hip prosthesis, measured during the simulated intraoperative test.
Collapse
Affiliation(s)
- Stanisław Burzyński
- Department of Mechanics of Materials and Structures, Faculty of Civil and Environmental Engineering, Gdańsk University of Technology, Gdańsk, Poland
| | - Agnieszka Sabik
- Department of Mechanics of Materials and Structures, Faculty of Civil and Environmental Engineering, Gdańsk University of Technology, Gdańsk, Poland
| | - Wojciech Witkowski
- Department of Mechanics of Materials and Structures, Faculty of Civil and Environmental Engineering, Gdańsk University of Technology, Gdańsk, Poland
| | - Piotr Łuczkiewicz
- II Clinic of Orthopaedics and Kinetic Organ Traumatology, Medical University of Gdansk, Gdańsk, Poland
| |
Collapse
|
8
|
Yetkin C, Yildirim T, Alpay Y, Tas SK, Buyukkuscu MO, Dırvar F. Evaluation of Dislocation Risk Factors With Total Hip Arthroplasty in Developmental Hip Dysplasia Patients: A Multivariate Analysis. J Arthroplasty 2021; 36:636-640. [PMID: 32943316 DOI: 10.1016/j.arth.2020.08.043] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/18/2020] [Revised: 07/03/2020] [Accepted: 08/21/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND This study aimed to investigate the risk factors for dislocation in patients diagnosed with developmental dysplasia of the hip (DDH) who underwent total hip arthroplasty. METHODS We retrospectively reviewed 40 patients who developed dislocation and compared them with 400 patients in the control group without hip instability. Patients-, surgery-, and implant-related factors were investigated. Risk factors were evaluated using multivariate logistic regression. RESULTS The mean follow-up period was 32.3 months. The mean time to dislocation was 4.4 months. There were 7 men (17.5%) and 33 women (82.5%) in the dislocation group and 83 men (20.7%) and 317 women (79.3%) in the control group (P = .627). Diabetes mellitus (DM; P = .032) and history of previous hip surgery for DDH were associated with dislocation (P < .001). The subtrochanteric shortening osteotomy (P = .001), acetabular inclination (P = .037), acetabular anteversion (P < .001), femoral head size (P < .001), and postoperative infection (P = .003) were associated with dislocation. Major predictors of hip dislocation after total hip arthroplasty in patients with DDH were previous hip surgery (odds ratio [OR], 6.76; 95% confidence interval [CI], 1.86-24.6; P = .004), high hip center (OR, 2.90; 95% CI, 1.31-6.38; P = .008), DM (OR, 2.68; 95% CI, 1.06-6.80; P = .037), and acetabular inclination (OR, 2.62; 95% CI, 1.09-6.26; P = .03). CONCLUSION Patients with DM and previous hip surgery should be informed about increased dislocation rates. Using a larger head diameter and restoration of the true hip rotation center are essential to prevent hip dislocation in these patients. Furthermore, accurate positioning of the acetabular inclination and anteversion are also important.
Collapse
Affiliation(s)
- Cem Yetkin
- Department of Orthopedics, Çan State Hospital, Çanakkale, Turkey
| | - Timur Yildirim
- Baltalimani Bone Diseases Training and Research Center, University of Health Sciences Istanbul, Turkey
| | - Yakup Alpay
- Department of Orthopedics, Sultanbeyli State Hospital, Istanbul, Turkey
| | - Suleyman K Tas
- Department of Orthopedics, Hakkari State Hospital, Hakkari, İstanbul, Turkey
| | | | - Ferdi Dırvar
- Baltalimani Bone Diseases Training and Research Center, University of Health Sciences Istanbul, Turkey
| |
Collapse
|
9
|
Sidhu GAS, Kaur H, Singh H, Hind J, Ashwood N. Prospective Study Showing Results of Large-Diameter Femoral Heads After Cementless Total Hip Replacement. Cureus 2021; 13:e12610. [PMID: 33585100 PMCID: PMC7877256 DOI: 10.7759/cureus.12610] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
Introduction Large-diameter femoral heads (≥36 mm) were introduced to decrease instability and improve the range of motion of the hip. We hypothesized regarding the clinical outcome and complications (dislocation, implant survivorship, and functional scores) following total hip replacement (THR) surgery in an Indian population who have smaller acetabulum compared to the western population. Methodology A prospective study was conducted at a tertiary hospital from November 2011 to July 2013. A total of 70 patients with hip pathology were operated by a senior surgeon for THR using the anterolateral approach. The Harris Hip Scores were recorded pre and postoperatively in all patients. Postoperatively, radiographs were taken to check for evidence of implant loosening or osteolysis. The patients were followed up till a mean follow-up of 86.52 months (range: 74 to 108 months) in our cohort. Detailed clinical and radiographic results were available for 59 patients, while six died (three died of myocardial infarction (MI), two had cerebrovascular accident (CVA), and one patient died of pulmonary embolism) and five patients were lost to follow-up. Results Of the 59 hips, majority (76%) had acetabular inclination of 46-55 degrees. Ninety percent of the stems were in the central position and 10% were in the varus position. The average preoperative Harris Hip Score was 38.8 ± 5.7 (range: 24-46), which increased to 90.4 ± 7.3 (range: 78-94) at the last follow-up. A total of six patients died (four died of MI and two of CVA) and two patients had infection which was treated with antibiotics. Three cases of dislocation were observed; one following a fall one year after surgery and revision total hip arthroplasty was done and two cases while getting up from the bed which were managed with closed reduction and abduction brace for six weeks. Two cases of periprosthetic fracture were observed which were managed with plating. Conclusion Lower dislocation rate and better range of movement reinforces the advantage of large-diameter femoral head during THR in the Indian population.
Collapse
Affiliation(s)
- Gur Aziz Singh Sidhu
- Trauma and Orthopaedics, University Hospitals of Derby and Burton, Burton, GBR.,Trauma and Orthopaedics, Dayanand Medical College and Hospital, Ludhiana, IND
| | - Harjot Kaur
- Anesthesia, Dayanand Medical College and Hospital, Ludhiana, IND
| | - Hakam Singh
- Trauma and Orthopaedics, Dayanand Medical College and Hospital, Ludhiana, IND
| | - Jamie Hind
- Trauma and Orthopaedics, University Hospitals of Derby and Burton, Burton, GBR
| | - Neil Ashwood
- Trauma and Orthopaedics, University Hospitals of Derby and Burton, Burton, GBR
| |
Collapse
|
10
|
Hernandez NM, Steele JR, Wu CJ, Cunningham DJ, Aggrey GK, Bolognesi MP, Wellman SS. A Specific Capsular Repair Technique Lowered Early Dislocations in Primary Total Hip Arthroplasty Through a Posterior Approach. Arthroplast Today 2020; 6:813-818. [PMID: 32995415 PMCID: PMC7509067 DOI: 10.1016/j.artd.2020.07.044] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/08/2020] [Revised: 07/17/2020] [Accepted: 07/22/2020] [Indexed: 11/18/2022] Open
Abstract
BACKGROUND Dislocation is a challenging problem after total hip arthroplasty (THA). We sought to evaluate the incidence of early dislocation with 2 different posterior repair techniques after THA using a posterior approach. METHODS From September of 2008 to August of 2019, we evaluated 841 THAs performed by a single surgeon using a posterior approach. Before November of 2015, the capsule was repaired to the greater trochanter (group 1, 605 patients). Starting November 2015, the posterior capsule was repaired in a side-to-side fashion (direct soft-tissue repair) (group 2, 236 patients). There was a mean follow-up of 31.1 months (range, 2.5-122.5 months). A multivariable logistic regression model was constructed to assess the impact of baseline patient and operative factors on the dislocation rate. RESULTS There were 22 dislocations, all of which occurred in group 1. There were no dislocations in group 2. After adjusting for patient and operative factors, the direct soft-tissue repair had a large impact on the overall multivariable model as indicated by its effect likelihood ratio of 10.33 (P = .001); however, the odds ratio was not calculable for this factor, given that there were no dislocations in hips with direct soft-tissue repair. Increasing age was associated with an increased odds of dislocation (odds ratio, 1.04, P = .017), with an effect likelihood ratio of 6.25 (P = .012). CONCLUSIONS Switching from a capsular repair to the greater trochanter to a side-to-side capsular repair was associated with a decreased rate of dislocation in primary THA through a posterior approach.
Collapse
Affiliation(s)
- Nicholas M Hernandez
- Department of Orthopaedic Surgery, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
| | - John R Steele
- Department of Orthopaedic Surgery, Duke University, Durham, NC, USA
| | | | | | - Gerald K Aggrey
- Department of Orthopaedic Surgery, Duke University, Durham, NC, USA
| | | | - Samuel S Wellman
- Department of Orthopaedic Surgery, Duke University, Durham, NC, USA
| |
Collapse
|
11
|
Stangl-Correa P, Stangl-Herrera W, Correa-Valderrama A, Ron-Translateur T, Cantor EJ, Palacio-Villegas JC. Postoperative Failure Frequency of Short External Rotator and Posterior Capsule With Successful Reinsertion After Primary Total Hip Arthroplasty: An Ultrasound Assessment. J Arthroplasty 2020; 35:3607-3612. [PMID: 32684400 DOI: 10.1016/j.arth.2020.06.065] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/13/2020] [Revised: 06/20/2020] [Accepted: 06/23/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND The reinsertion of the short external rotators and posterior capsule to the greater trochanter in the posterolateral approach has been considered an effective strategy to reduce the risk of dislocation. However, during clinical practice, no verification and monitoring of the status of such reinsertions is carried out. The objective of this study is to estimate the frequency of postoperative failure with successful reinsertion of the short external rotator and posterior capsule of the hip through ultrasound after primary total hip arthroplasty (THA) using the posterolateral approach. METHODS A prospective observational study was conducted involving patients with primary total hip arthroplasty via posterolateral approach in which reinsertion of hip's short external rotators and posterior capsule were successful reinserted during surgery from January to December 2019. The status of the reinsertion was assessed with an ultrasound between the 6 and 8 weeks after surgery. Reinsertion failure was considered when the reinserted structures were not fully visualized in the ultrasound during internal and external rotation. RESULTS Sixty-eight patients were included in this study (mean age: 58.7 ± 13.8 years; 44.1% (30) women). The incidence of failure of the reinsertion of short external rotators and posterior capsule was 16.2% (n = 11) (95% confidence interval 9.3-26.7). A postoperative increased femoral offset was found more frequently in cases with failure (36.4% vs 17.5%); a similar trend was observed in the leg length discrepancy (36.4% vs 22.8%). However, these differences were not statistically significant (P > .05). CONCLUSION Between the 6th and 8th postoperative week, approximately 2 of the 10 short external rotator and posterior capsule reinsertions fail in cases with successful intraoperative repair using absorbable suture. This estimate is comparable and even lower than previous reports. EVIDENCE LEVEL II, Prospective Observational Study.
Collapse
Affiliation(s)
- Paul Stangl-Correa
- Joint Replacement Group, Institute of Osteoarticular Disease, Centro Médico Imbanaco, Cali, Colombia; Faculty of Medicine, Universidad Javeriana, Javeriana, Bogotá, Colombia
| | - Willy Stangl-Herrera
- Joint Replacement Group, Institute of Osteoarticular Disease, Centro Médico Imbanaco, Cali, Colombia; Surgical Clinics Department, Pontificia Universidad Javeriana, Cali, Colombia
| | - Andrés Correa-Valderrama
- Joint Replacement Group, Institute of Osteoarticular Disease, Centro Médico Imbanaco, Cali, Colombia; Surgical Clinics Department, Pontificia Universidad Javeriana, Cali, Colombia
| | - Tamy Ron-Translateur
- Joint Replacement Group, Institute of Osteoarticular Disease, Centro Médico Imbanaco, Cali, Colombia
| | - Erika J Cantor
- Institute of Statistics, Universidad de Valparaiso, Valparaiso, Chile
| | - Julio C Palacio-Villegas
- Joint Replacement Group, Institute of Osteoarticular Disease, Centro Médico Imbanaco, Cali, Colombia; Surgical Clinics Department, Pontificia Universidad Javeriana, Cali, Colombia
| |
Collapse
|
12
|
Wolf O, Mukka S, Notini M, Möller M, Hailer NP. Study protocol: The DUALITY trial-a register-based, randomized controlled trial to investigate dual mobility cups in hip fracture patients. Acta Orthop 2020; 91:506-513. [PMID: 32567472 PMCID: PMC8023882 DOI: 10.1080/17453674.2020.1780059] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Physically and mentally fit patients with a displaced femoral neck fracture (FNF) are mostly treated with total hip arthroplasty (THA). Dislocation is a severe and frequent complication in this group, and dual mobility cups (DMC) were developed to reduce the risk of dislocation after THA. The DUALITY trial investigates whether the use of DMC in FNF patients treated with a THA reduces the risk of dislocation.Patients and methods - The trial is a national, multicenter, register-based, randomized controlled trial (rRCT). Patients ≥ 65 years with a non-pathological, displaced FNF (Type Garden 3-4/AO 31-B2 or B3) who are suitable for a THA according to local guidelines are assessed for eligibility using the web-based registration platform of the Swedish Fracture Register (SFR). 1,600 patients will be randomized 1:1 to either insertion of a DMC (intervention group) or a standard cup (control group). The study is pragmatic in that the choice of implant brands, surgical approach, and peri- and postoperative protocols follow the local routines of each participating unit. All outcome variables will be retrieved after linkage of the study cohort obtained from the SFR with the Swedish Hip Arthroplasty Register and the National Patient Register.Outcomes - The primary outcome is the occurrence of any dislocation of the index joint treated with closed or open reduction within 1 year after surgery, expressed as a relative risk when comparing groups, and a risk reduction of at least 45% is considered clinically relevant. Secondary outcomes are the relative risk of any reoperation of the index joint, periprosthetic joint infection, and mortality within 90 days and 1 year. Patient-reported outcomes and health economics are evaluated.Start of trial and estimated duration - The DUALITY trial started recruiting patients in January 2020 and will continue for approximately 5 years.Trial registration - The trial is registered at clinicaltrials.gov (NCT03909815; December 12, 2019).
Collapse
Affiliation(s)
- Olof Wolf
- Department of Surgical Sciences, Orthopaedics, Uppsala University; ,Correspondence:
| | - Sebastian Mukka
- Department of Surgical and Perioperative Science (Orthopaedics), Umeå University;
| | - Maja Notini
- Department of Surgical Sciences, Orthopaedics, Uppsala University;
| | - Michael Möller
- Institute of Clinical Science, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Nils P Hailer
- Department of Surgical Sciences, Orthopaedics, Uppsala University;
| | | |
Collapse
|
13
|
Choong ALC, Shadbolt C, Dowsey MM, Choong PFM. Sex-based differences in the outcomes of total hip and knee arthroplasty: a narrative review. ANZ J Surg 2020; 91:553-557. [PMID: 32954641 DOI: 10.1111/ans.16299] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2020] [Revised: 08/18/2020] [Accepted: 08/19/2020] [Indexed: 11/30/2022]
Abstract
Total joint arthroplasty (TJA) is an effective treatment for end-stage osteoarthritis, which aims to alleviate pain and improve function and mobility. Despite the remarkable success of TJA, complications can arise, leading to unplanned hospital readmission, implant failure, morbidity and mortality. Recently, there has been a growing interest in analysing sex-based differences in diseases and response to medical interventions. This review summaries evidence pertaining to the widening gap between men and women regarding the utilization and outcome of TJA surgery. Interactions between sex and patient-reported outcome, implant failure and medical complication are complex and often demonstrate conflicting results. Significantly, there is a global consensus that men are at a higher risk of developing prosthetic joint infection following joint arthroplasty. Guided by the literature, there is a clear need for standardized methods of collecting, analysing and reporting sex-specific data to improve outcomes for both men and women who undergo TJA.
Collapse
Affiliation(s)
- Annabelle L C Choong
- Department of Surgery, The University of Melbourne, St. Vincent's Hospital Melbourne, Melbourne, Victoria, Australia.,Department of Orthopaedics, St. Vincent's Hospital, Melbourne, Victoria, Australia
| | - Cade Shadbolt
- Department of Surgery, The University of Melbourne, St. Vincent's Hospital Melbourne, Melbourne, Victoria, Australia
| | - Michelle M Dowsey
- Department of Surgery, The University of Melbourne, St. Vincent's Hospital Melbourne, Melbourne, Victoria, Australia.,Department of Orthopaedics, St. Vincent's Hospital, Melbourne, Victoria, Australia
| | - Peter F M Choong
- Department of Surgery, The University of Melbourne, St. Vincent's Hospital Melbourne, Melbourne, Victoria, Australia.,Department of Orthopaedics, St. Vincent's Hospital, Melbourne, Victoria, Australia
| |
Collapse
|
14
|
Yang Q, Wang J, Xu Y, Chen Y, Lian Q, Zhang Y. Incidence and risk factors of in-hospital prosthesis-related complications following total hip arthroplasty: a retrospective Nationwide Inpatient Sample database study. INTERNATIONAL ORTHOPAEDICS 2020; 44:2243-2252. [DOI: 10.1007/s00264-020-04682-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/27/2020] [Accepted: 06/22/2020] [Indexed: 12/14/2022]
|
15
|
Alastruey-López D, Ezquerra L, Seral B, Pérez MA. Using artificial neural networks to predict impingement and dislocation in total hip arthroplasty. Comput Methods Biomech Biomed Engin 2020; 23:649-657. [PMID: 32364804 DOI: 10.1080/10255842.2020.1757661] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
Dislocation after total hip arthroplasty (THA) remains a major issue and an important post-surgical complication. Impingement and subsequent dislocation are influenced by the design (head size) and position (anteversion and abduction angles) of the acetabulum and different movements of the patient, with external extension and internal flexion the most critical movements. The aim of this study is to develop a computational tool based on a three-dimensional (3D) parametric finite element (FE) model and an artificial neural network (ANN) to assist clinicians in identifying the optimal prosthesis design and position of the acetabular cup to reduce the probability of impingement and dislocation. A 3D parametric model of a THA was used. The model parameters were the femoral head size and the acetabulum abduction and anteversion angles. Simulations run with this parametric model were used to train an ANN, which predicts the range of movement (ROM) before impingement and dislocation. This study recreates different configurations and obtains absolute errors lower than 5.5° between the ROM obtained from the FE simulations and the ANN predictions. The ROM is also predicted for patients who had already suffered dislocation after THA, and the computational predictions confirm the patient's dislocations. Summarising, the combination of a 3D parametric FE model of a THA and an ANN is a useful computational tool to predict the ROM allowed for different designs of prosthesis heads.
Collapse
Affiliation(s)
- D Alastruey-López
- M2BE-Multiscale in Mechanical and Biological Engineering, Instituto de Investigación en Ingeniería de Aragón (I3A), Aragón Institute of Health Science (IACS), Universidad de Zaragoza, Zaragoza, España
| | | | - B Seral
- M2BE-Multiscale in Mechanical and Biological Engineering, Instituto de Investigación en Ingeniería de Aragón (I3A), Aragón Institute of Health Science (IACS), Universidad de Zaragoza, Zaragoza, España.,University Clinic Hospital "Lozano Blesa", Aragón Institute of Health Science (IACS), University of Zaragoza, Zaragoza, Spain
| | - M A Pérez
- M2BE-Multiscale in Mechanical and Biological Engineering, Instituto de Investigación en Ingeniería de Aragón (I3A), Aragón Institute of Health Science (IACS), Universidad de Zaragoza, Zaragoza, España
| |
Collapse
|
16
|
Hip stress distribution - Predictor of dislocation in hip arthroplasties. A retrospective study of 149 arthroplasties. PLoS One 2019; 14:e0225459. [PMID: 31747433 PMCID: PMC6867650 DOI: 10.1371/journal.pone.0225459] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2019] [Accepted: 11/05/2019] [Indexed: 12/14/2022] Open
Abstract
Dislocation after hip arthroplasty is still a major concern. Recent study of the volumetric wear of the cup has suggested that stresses studied in a one-legged stance model could predispose arthroplasty dislocation. The aim of this work was to study whether biomechanical parameters of contact stress distribution in total hip arthroplasty during a neutral hip position can predict a higher possibility of the arthroplasty dislocating. Biomechanical parameters were determined using 3-dimensional mathematical models of the one-legged stance within the HIPSTRESS method. Geometrical parameters were measured from standard anteroposterior X-ray images of the pelvis and proximal femora. Fifty-five patients subjected to total hip arthroplasty that later suffered dislocation of the head and, for comparison, ninety-four total hip arthroplasties that were functional at least 10 years after the implantation, were included in the study. Arthroplasties that suffered dislocation had on average a 6% higher resultant hip force than the control group (p = 0.004), 11% higher peak stress on the load-bearing area (p = 0.001) and a 50% more laterally positioned stress pole (p = 0.026), all parameters being less favorable in the group of unstable arthroplasties. There was no statistically significant difference in the gradient index or in the functional angle of the weight bearing. Our study showed that arthroplasties that show a tendency to push the head out of the cup in the representative body position—the one-legged stance—are prone to dislocation. An unfavorable resultant hip force, peak stress on the load bearing and laterally positioned stress pole are predictors of arthroplasty dislocation.
Collapse
|
17
|
Basques BA, Bell JA, Fillingham YA, Khan JM, Della Valle CJ. Gender Differences for Hip and Knee Arthroplasty: Complications and Healthcare Utilization. J Arthroplasty 2019; 34:1593-1597.e1. [PMID: 31003781 DOI: 10.1016/j.arth.2019.03.064] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/04/2018] [Revised: 03/25/2019] [Accepted: 03/26/2019] [Indexed: 02/01/2023] Open
Abstract
INTRODUCTION The influence of patient gender on complications and healthcare utilization remains unexplored. The purpose of the present study was to determine if patient gender significantly affected outcomes following total hip arthroplasty (THA) and total knee arthroplasty (TKA). METHODS Retrospective cohort study of THA and TKA patients was performed using the Nationwide Inpatient Sample from 2002 to 2011. Only patients who underwent elective procedures and those with complete perioperative data were included. Multivariate logistic regression was used to compare the rates of adverse events between male and female cohorts while controlling for baseline characteristics. RESULTS A total of 6,123,637 patients were included in the study (31.2% THA and 68.8% TKA). The cohort was 61.1% female. While males had a lower rate of any adverse event (odds ratio [OR] = 0.8, P < .001), urinary tract infection (OR = 0.4, P < .001), deep vein thrombosis/pulmonary embolism (OR = 0.9, P < .001), and blood transfusion (OR = 0.5, P < .001), male gender was associated with statistically significant increases in the rates of death (OR = 1.6, P < .001), acute kidney injury (OR = 1.6, P < .001), cardiac arrest (OR = 1.7, P < .001), myocardial infarction (OR = 1.6, P < .001), pneumonia (OR = 1.1, P < .001), sepsis (OR = 1.6, P < .001), surgical site infection (OR = 1.4, P < .001), and wound dehiscence (OR = 1.4, P < .001). CONCLUSION Males had increased rates of many individual adverse events. Females had higher rates of urinary tract infection, which translated to an overall higher rate of adverse events in females because of the rarity of the other individual adverse events.
Collapse
Affiliation(s)
- Bryce A Basques
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL
| | - Joshua A Bell
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL
| | - Yale A Fillingham
- Department of Orthopaedic Surgery, Dartmouth-Hitchcock Medical Center, Lebanon, NH
| | - Jannat M Khan
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL
| | - Craig J Della Valle
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL
| |
Collapse
|
18
|
Prevalence of Anterior Femoral Neck Osteophyte in a Total Hip Arthroplasty Population: Analysis of Preoperative Surgical Plans. Adv Orthop 2019; 2019:5193945. [PMID: 30941222 PMCID: PMC6420987 DOI: 10.1155/2019/5193945] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/07/2018] [Accepted: 01/15/2019] [Indexed: 11/23/2022] Open
Abstract
Despite strongly positive results of total hip arthroplasty (THA), patients remain at risk for complications including dislocation. Spinopelvic motion and the hip-spine relationship have been recognized as important factors in surgical planning and implant positioning in THA. Periarticular osteophytes are one of the hallmark pathoanatomic features of osteoarthritis and may influence implant positioning and joint stability; residual osteophytes at the anterior femoral neck may cause anterior impingement and posterior instability. No studies have been identified which establish the prevalence of anterior femoral neck osteophyte for incorporation into THA planning. 413 consecutive patients scheduled for THA underwent preoperative planning taking into account spinopelvic motion to establish optimal component position. Each surgical plan was reviewed retrospectively by four independent raters who were blinded to other imaging and intraoperative findings. Anterior femoral neck osteophytes were rated as being absent, minor, or extensive for each case. A single outlying rater was excluded. Inter-rater reliability was calculated manually. The patient group comprised 197 male and 216 female hips, with a mean age of 63 years (range 32–91). The presence of anterior femoral neck osteophytes was identified in a mean of 82% of cases (range 78–86%). A significant number of patients were found to have large or extensive osteophytes present in this location (mean 27%; range 23–31%). Inter-rater reliability was 70%. A large majority of our THA patients were found to have anterior femoral neck osteophytes. These must be considered during preoperative planning with respect to the spinopelvic relationship. Failure to identify and address osteophytes intraoperatively may increase the risk of impingement in flexion and/or internal rotation, leading to decreased range of motion, joint instability, and possibly dislocation. Planned future directions include incorporation of an impingement and instability model into preoperative planning for THA.
Collapse
|
19
|
Gromov K, Troelsen A, Modaddes M, Rolfson O, Furnes O, Hallan G, Eskelinen A, Neuvonen P, Husted H. Varying but reduced use of postoperative mobilization restrictions after primary total hip arthroplasty in Nordic countries: a questionnaire-based study. Acta Orthop 2019; 90:143-147. [PMID: 30739539 PMCID: PMC6461082 DOI: 10.1080/17453674.2019.1572291] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Mobilization has traditionally been restricted following total hip arthroplasty (THA) in an attempt to reduce the risk of dislocation and muscle detachment. However, recent studies have questioned the effect and rationale underlying such restrictions. We investigated the use of postoperative restrictions and possible differences in mobilization protocols following primary THA in Denmark (DK), Finland (FIN), Norway (NO), and Sweden (SWE). Patients and methods - All hospitals performing primary THA in the participating countries were identified from the latest national THA registry report. A questionnaire containing questions regarding standard surgical procedure, use of restrictions, and postoperative mobilization protocol was distributed to all hospitals through national representatives for each arthroplasty registry. Results - 83% to 94% (n = 167) of the 199 hospitals performing THA in DK, FIN, NO, and SWE returned correctly filled out questionnaires. A posterolateral approach was used by 77% of the hospitals. 92% of the hospitals had a standardized mobilization protocol. 50%, 41%, 19%, and 38% of the hospitals in DK, FIN, NO, and SWE, respectively, did not have any postoperative restrictions. If utilized, restrictions were applied for a median of 6 weeks. Two-thirds of all hospitals have changed their mobilization protocol within the last 5 years-all but 2 to a less restrictive protocol. Interpretation - Use of postoperative restrictions following primary THA differs between the Nordic countries, with 19% to 50% allowing mobilization without any restrictions. There has been a strong tendency towards less restrictive mobilization over the last 5 years.
Collapse
Affiliation(s)
- Kirill Gromov
- Department of Orthopaedic Surgery, Copenhagen University Hospital Hvidovre, Denmark; ,Danish Hip Arthroplasty Registry; ,Correspondence:
| | - Anders Troelsen
- Department of Orthopaedic Surgery, Copenhagen University Hospital Hvidovre, Denmark;
| | - Maziar Modaddes
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; ,Swedish Hip Arthroplasty Register;
| | - Ola Rolfson
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; ,Swedish Hip Arthroplasty Register;
| | - Ove Furnes
- The Norwegian Arthroplasty Register, Department of Orthopaedic Surgery, Haukeland University Hospital, Bergen, Norway; ,Department of Clinical Medicine, University of Bergen, Norway;
| | - Geir Hallan
- The Norwegian Arthroplasty Register, Department of Orthopaedic Surgery, Haukeland University Hospital, Bergen, Norway; ,Department of Clinical Medicine, University of Bergen, Norway;
| | - Antti Eskelinen
- Coxa Hospital for Joint Replacement, and Faculty of Medicine and Life Sciences, University of Tampere, Tampere, Finland; ,Finnish Hip Arthroplasty Registry
| | - Perttu Neuvonen
- Coxa Hospital for Joint Replacement, and Faculty of Medicine and Life Sciences, University of Tampere, Tampere, Finland; ,Finnish Hip Arthroplasty Registry
| | - Henrik Husted
- Department of Orthopaedic Surgery, Copenhagen University Hospital Hvidovre, Denmark;
| |
Collapse
|
20
|
Jones CW, De Martino I, D'Apolito R, Nocon AA, Sculco PK, Sculco TP. The use of dual-mobility bearings in patients at high risk of dislocation. Bone Joint J 2019; 101-B:41-45. [PMID: 30648492 DOI: 10.1302/0301-620x.101b1.bjj-2018-0506.r1] [Citation(s) in RCA: 49] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS Instability continues to be a troublesome complication after total hip arthroplasty (THA). Patient-related risk factors associated with a higher dislocation risk include the preoperative diagnosis, an age of 75 years or older, high body mass index (BMI), a history of alcohol abuse, and neurodegenerative diseases. The goal of this study was to assess the dislocation rate, radiographic outcomes, and complications of patients stratified as high-risk for dislocation who received a dual mobility (DM) bearing in a primary THA at a minimum follow-up of two years. MATERIALS AND METHODS We performed a retrospective review of a consecutive series of DM THA performed between 2010 and 2014 at our institution (Hospital for Special Surgery, New York, New York) by a single, high-volume orthopaedic surgeon employing a single prosthesis design (Anatomic Dual Mobility (ADM) Stryker, Mahwah, New Jersey). Patient medical records and radiographs were reviewed to confirm the type of implant used, to identify any preoperative risk factors for dislocation, and any complications. Radiographic analysis was performed to assess for signs of osteolysis or remodelling of the acetabulum. RESULTS There were 151 patients who met the classification of high-risk according to the inclusion criteria and received DM THA during the study period. Mean age was 82 years old (73 to 95) and 114 patients (77.5%) were female. Mean follow-up was 3.6 years (1.9 to 6.1), with five patients lost to follow-up and one patient who died (for a reason unrelated to the index procedure). One patient (0.66%) sustained an intraprosthetic dislocation; there were no other dislocations. CONCLUSION At mid-term follow-up, the use of a DM bearing for primary THA in patients at high risk of dislocation provided a stable reconstruction option with excellent radiographic results. Longer follow-up is needed to confirm the durability of these reconstructions.
Collapse
Affiliation(s)
- C W Jones
- University of Sydney, Sydney, Australia
| | - I De Martino
- Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, New York, USA
| | - R D'Apolito
- Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, New York, USA
| | - A A Nocon
- Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, New York, USA
| | - P K Sculco
- Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, New York, USA
| | - T P Sculco
- Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, New York, USA
| |
Collapse
|
21
|
A comparative study about the incidence of dislocation and peri-prosthetic fracture between dual mobility versus standard cups after primary total hip arthroplasty. INTERNATIONAL ORTHOPAEDICS 2019; 43:2691-2695. [DOI: 10.1007/s00264-018-4279-y] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/30/2018] [Accepted: 12/18/2018] [Indexed: 01/18/2023]
|
22
|
Snijders TE, Willemsen K, van Gaalen SM, Castelein RM, Weinans H, de Gast A. Lack of consensus on optimal acetabular cup orientation because of variation in assessment methods in total hip arthroplasty: a systematic review. Hip Int 2019; 29:41-50. [PMID: 29772949 DOI: 10.1177/1120700018759306] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION: Dislocation is 1 of the main reasons for revision of total hip arthroplasty but dislocation rates have not changed in the past decades, compromising patients' well-being. Acetabular cup orientation plays a key role in implant stability and has been widely studied. This article investigates whether there is a consensus on optimal cup orientation, which is necessary when using a navigation system. METHODS: A systematic search of the literature in the PubMed, Embase and Cochrane databases was performed (March 2017) to identify articles that investigated the direct relationship between cup orientation and dislocation, including a thorough evaluation of postoperative cup orientation assessment methods. RESULTS: 28 relevant articles evaluating a direct relation between dislocation and cup orientation could not come to a consensus. The key reason is a lack of uniformity in the assessment of cup orientation. Cup orientation is assessed with different imaging modalities, different methodologies, different definitions for inclination and anteversion, several reference planes and distinct patient positions. CONCLUSIONS: All available studies lack uniformity in cup orientation assessment; therefore it is impossible to reach consensus on optimal cup orientation. Using navigation systems for placement of the cup is inevitably flawed when using different definitions in the preoperative planning, peroperative placement and postoperative evaluation. Further methodological development is required to assess cup orientation. Consequently, the postoperative assessment should be uniform, thus differentiating between anterior and posterior dislocation, use the same definitions for inclination and anteversion with the same reference plane and with the patient in the same position.
Collapse
Affiliation(s)
- Thom E Snijders
- 1 Clinical Orthopedic Research Centre - mN, Zeist, Utrecht, The Netherlands
| | - Koen Willemsen
- 1 Clinical Orthopedic Research Centre - mN, Zeist, Utrecht, The Netherlands
| | | | - Rene M Castelein
- 2 Department of Orthopaedics, University Medical Centre Utrecht, Utrecht, The Netherlands.,3 Department of Rheumatology, University Medical Center Utrecht, Utrecht, The Netherlands.,4 Department of Biomechanical Engineering, Delft University of Technology, Delft, The Netherlands
| | - Harrie Weinans
- 2 Department of Orthopaedics, University Medical Centre Utrecht, Utrecht, The Netherlands.,3 Department of Rheumatology, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Arthur de Gast
- 1 Clinical Orthopedic Research Centre - mN, Zeist, Utrecht, The Netherlands
| |
Collapse
|
23
|
Abstract
BACKGROUND Prevention of dislocation after primary total hip arthroplasty (THA) begins with patient preoperative assessment and planning. METHODS We performed a literature search to assess historical perspectives and current strategies to prevent dislocation after primary THA. The search yielded 3458 articles, and 154 articles are presented. RESULTS Extremes of age, body mass index >30 kg/m2, lumbosacral pathology, surgeon experience, and femoral head size influence dislocation rates after THA. There is mixed evidence regarding the effect of neuromuscular disease, sequelae of pediatric hip conditions, and surgical approach on THA instability. Sex, simultaneous bilateral THA, and restrictive postoperative precautions do not influence the dislocation rates of THA. Navigation, robotics, lipped liners, and dual-mobility acetabular components may improve dislocation rates. CONCLUSIONS Risks for dislocation should be identified, and measures should be taken to mitigate the risk. Reliance on safe zones of acetabular component positioning is historical. We are in an era of bespoke THA surgery.
Collapse
|
24
|
Penenberg BL, Samagh SP, Rajaee SS, Woehnl A, Brien WW. Digital Radiography in Total Hip Arthroplasty: Technique and Radiographic Results. J Bone Joint Surg Am 2018; 100:226-235. [PMID: 29406344 DOI: 10.2106/jbjs.16.01501] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Obtaining the ideal acetabular cup position in total hip arthroplasty remains a challenge. Advancements in digital radiography and image analysis software allow the assessment of the cup position during the surgical procedure. This study describes a validated technique for evaluating cup position during total hip arthroplasty using digital radiography. METHODS Three hundred and sixty-nine consecutive patients undergoing total hip arthroplasty were prospectively enrolled. Preoperative supine anteroposterior pelvic radiographs were made. Intraoperative anteroposterior pelvic radiographs were made with the patient in the lateral decubitus position. Radiographic beam angle adjustments and operative table adjustments were made to approximate rotation and tilt of the preoperative radiograph. The target for cup position was 30° to 50° abduction and 15° to 35° anteversion. Intraoperative radiographic measurements were calculated and final cup position was determined after strict impingement and range-of-motion testing. Postoperative anteroposterior pelvic radiographs were made. Two independent observers remeasured all abduction and anteversion angles. RESULTS Of the cups, 97.8% were placed within 30° to 50° of abduction, with a mean angle (and standard deviation) of 39.5° ± 4.6°. The 2.2% of cups placed outside the target zone were placed so purposefully on the basis of intraoperative range-of-motion testing and patient factors, and 97.6% of cups were placed between 15° and 35° of anteversion, with a mean angle of 26.6° ± 4.7°. Twenty-eight percent of cups were repositioned on the basis of intraoperative measurements. Subluxation during range-of-motion testing occurred in 3% of hips despite acceptable measurements, necessitating cup repositioning. There was 1 early anterior dislocation. CONCLUSIONS Placing the acetabular component within a target range is a critical component to minimizing dislocation and polyethylene wear in total hip arthroplasty. Using digital radiography, we positioned the acetabular component in our desired target zone in 97.8% of cases and outside the target zone, purposefully, in 2.2% of cases. When used in conjunction with strict impingement testing, digital radiography allows for predictable cup placement in total hip arthroplasty.
Collapse
Affiliation(s)
- Brad L Penenberg
- Department of Orthopaedic Surgery, Cedars-Sinai Medical Center, Los Angeles, California
| | - Sanjum P Samagh
- Department of Orthopaedic Surgery, Cedars-Sinai Medical Center, Los Angeles, California
| | - Sean S Rajaee
- Department of Orthopaedic Surgery, Cedars-Sinai Medical Center, Los Angeles, California
| | - Antonia Woehnl
- Department of Orthopaedic Surgery, Cedars-Sinai Medical Center, Los Angeles, California
| | | |
Collapse
|
25
|
Kruse C, Rosenlund S, Broeng L, Overgaard S. Radiographic cup position following posterior and lateral approach to total hip arthroplasty. An explorative randomized controlled trial. PLoS One 2018; 13:e0191401. [PMID: 29377951 PMCID: PMC5788339 DOI: 10.1371/journal.pone.0191401] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2017] [Accepted: 12/18/2017] [Indexed: 01/20/2023] Open
Abstract
The two most common surgical approaches to total hip arthroplasty are the posterior approach and lateral approach. The surgical approach may influence cup positioning and restoration of the offset, which may affect the biomechanical properties of the hip joint. The primary aim was to compare cup position between posterior approach and lateral approach. Secondary aims were to compare femoral offset, abductor moment arm and leg length discrepancy between the two approaches. Eighty patients with primary hip osteoarthritis were included in a randomized controlled trial and assigned to total hip arthroplasty using posterior approach or lateral approach. Postoperative radiographs from 38 patients in each group were included in this study for measurement of cup anteversion and inclination. Femoral offset, cup offset, total offset, abductor moment arm and leg length discrepancy were measured on preoperative and postoperative radiographs in 28 patients in each group. We found that mean anteversion was 5° larger in the posterior approach group (95% CI, -8.1 to -1.4; p = 0.006), while mean inclination was 5° less steep (95% CI, 2.7 to 7.2; p<0.001) compared with the lateral approach group. The posterior approach group had a larger mean femoral offset of 4.3mm (95% CI, -7.4 to -1.3, p = 0.006), mean total offset of 6.3mm (95% CI, -9.6 to -3; p<0.001) and mean abductor moment arm of 4.8mm (95% CI, -7.6 to -1.9; p = 0.001) compared with the lateral approach group. We found a larger cup anteversion but less steep cup inclination in the posterior approach group compared with the lateral approach group. Femoral offset and abductor moment arm were restored after total hip arthroplasty using lateral approach but significantly increased when using posterior approach.
Collapse
Affiliation(s)
- Christine Kruse
- Department of Orthopaedic Surgery and Traumatology, Odense University Hospital and Institute of Clinical Research, University of Southern, Odense, Denmark
| | - Signe Rosenlund
- Department of Orthopaedic Surgery and Traumatology, Odense University Hospital and Institute of Clinical Research, University of Southern, Odense, Denmark
- Department of Orthopaedic Surgery and Traumatology, Zealand University Hospital, Køge, Denmark
- * E-mail:
| | - Leif Broeng
- Department of Orthopaedic Surgery and Traumatology, Zealand University Hospital, Køge, Denmark
| | - Søren Overgaard
- Department of Orthopaedic Surgery and Traumatology, Odense University Hospital and Institute of Clinical Research, University of Southern, Odense, Denmark
| |
Collapse
|
26
|
Amado O, Bautista M, Moore J, Bonilla G, Jimenez N, Llinás A. A multimodal approach prevents instability after total hip arthroplasty: A 1 year follow-up prospective study. J Clin Orthop Trauma 2018; 9:137-141. [PMID: 29896016 PMCID: PMC5995691 DOI: 10.1016/j.jcot.2016.11.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/02/2016] [Revised: 10/11/2016] [Accepted: 11/11/2016] [Indexed: 01/20/2023] Open
Abstract
INTRODUCTION Joint dislocation is one of the most frequent complications after hip arthroplasty. Multiple strategies have demonstrated ability to prevent instability when used in isolation, but the effect when more than one intervention is implemented has not been measured. The purpose of this study is to assess the rate of dislocation after implementation of a protocol of combined strategies for prevention of instability. MATERIALS AND METHODS Consecutive patients undergoing primary total hip replacement for hip osteoarthritis between February 2012 and June 2014 were included. A multimodal protocol including patient education, use of large femoral heads, posterior soft-tissue repair, and intraoperative adjustment of limb length and hip offset was applied. Dislocation episodes were documented trough medical records review and a telephonic follow-up at 3 and 12 months after surgery. RESULTS During the period of study 331 patients were included, mean age was 66 years and 68.8% were females. Only 0.91% of patients were lost to follow-up. Eighty-nine percent of patients received all interventions. Cumulative dislocation rate at 3 months was 0.60% and 0.90% at 12 months. CONCLUSIONS The implementation of a multimodal protocol for prevention of prosthesis instability produces a low rate of dislocation, which compares favorably with benchmarks. We recommend the use of a combination of multiple interventions to prevent this complication.
Collapse
Affiliation(s)
- Omar Amado
- Department of Orthopedics and Traumatology, Hospital Universitario Fundación Santa Fe de Bogotá, Carrera 7 No. 117 – 15, Bogota, Colombia
| | - Maria Bautista
- Department of Orthopedics and Traumatology, Hospital Universitario Fundación Santa Fe de Bogotá, Carrera 7 No. 117 – 15, Bogota, Colombia
| | - Jose Moore
- Department of Orthopedics and Traumatology, Hospital Universitario Fundación Santa Fe de Bogotá, Carrera 7 No. 117 – 15, Bogota, Colombia
| | - Guillermo Bonilla
- Department of Orthopedics and Traumatology, Hospital Universitario Fundación Santa Fe de Bogotá, Carrera 7 No. 117 – 15, Bogota, Colombia,School of Medicine, Universidad de los Andes, Bogota, Colombia,School of Medicine, Universidad del Rosario, Bogota, Colombia,Corresponding author at: Department of Orthopedics and Traumatology, Hospital Universitario Fundación Santa Fe de Bogotá, Carrera 7 No. 117 – 15, Zip Code: 110111186 Bogotá, D.C., Colombia.
| | - Nicolas Jimenez
- Department of Orthopedics and Traumatology, Hospital Universitario Fundación Santa Fe de Bogotá, Carrera 7 No. 117 – 15, Bogota, Colombia,School of Medicine, Universidad de los Andes, Bogota, Colombia
| | - Adolfo Llinás
- Department of Orthopedics and Traumatology, Hospital Universitario Fundación Santa Fe de Bogotá, Carrera 7 No. 117 – 15, Bogota, Colombia,School of Medicine, Universidad de los Andes, Bogota, Colombia,School of Medicine, Universidad del Rosario, Bogota, Colombia
| |
Collapse
|
27
|
Can Surgeons Reduce the Risk for Dislocation After Primary Total Hip Arthroplasty Performed Using the Posterolateral Approach? J Arthroplasty 2017. [PMID: 28625687 DOI: 10.1016/j.arth.2017.04.047] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
BACKGROUND Hip dislocation is one of the most common postoperative complications after total hip arthroplasty (THA). Potential contributors include patient- and surgical-related factors. We performed a retrospective cohort study to identify risk factors for postoperative dislocation in patients receiving THA via the posterolateral approach. METHODS We assessed 1326 consecutive primary THAs performed between 2010 and 2015. Patient information was documented, and plain radiographic films were used to evaluate cup positioning, hip offset, and hip length change. A multiple logistic regression was used to identify risk factors for dislocation. Follow-up was coordinated by the Danish National Patient Registry. RESULTS Age and American Society of Anesthesiologists scores were higher in dislocating THA compared with those in the nondislocating THA. Cup anteversion was less in dislocating THA compared with that in nondislocating THA. Independent risk factors for cup dislocation were increased age, body mass index <25 and >30 kg/m2, and leg shortening of >5 mm. CONCLUSION Surgeons should aim for a shortening of leg length <5 mm to reduce the risk of postoperative dislocation in primary THA. Although anteversion was reduced for dislocating THA, there is likely no universal safe zone for cup positioning. Hip stability is multifactorial, and optimal cup positioning may vary from patient to patient.
Collapse
|
28
|
Using nonlinear finite element models to analyse stress distribution during subluxation and torque required for dislocation of newly developed total hip structure after prosthetic impingement. Med Biol Eng Comput 2017; 56:37-47. [DOI: 10.1007/s11517-017-1673-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2016] [Accepted: 06/10/2017] [Indexed: 10/19/2022]
|
29
|
Leschinger T, Raiss P, Loew M, Zeifang F. Total shoulder arthroplasty: risk factors for intraoperative and postoperative complications in patients with primary arthritis. J Shoulder Elbow Surg 2017; 26:e71-e77. [PMID: 27745807 DOI: 10.1016/j.jse.2016.08.001] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/23/2016] [Revised: 07/25/2016] [Accepted: 08/01/2016] [Indexed: 02/01/2023]
Abstract
BACKGROUND This study evaluated and identified risk factors for the development of intraoperative and postoperative surgical complications in total shoulder arthroplasty in patients with primary osteoarthritis. METHODS We evaluated patient-specific factors, including age, sex, body mass index, prior nonarthroplasty surgery, smoking, alcohol consumption, and the American Society of Anesthesiologists (ASA) Physical Status Classification System in 275 patients (76 men, 199 women) with an average age of 68 years (range, 51-85 years). We categorized the number and severity of all complications and correlated these results with the patient-specific factors RESULTS: Twenty-seven complications (9.8%) in 275 shoulder arthroplasties were recorded. We identified 22 patients (8%) with category I complications and 5 (2.8%) with category II complications. Patients with an ASA score of 3 showed an increased likelihood of having a surgical complication compared with the control group with ASA scores of 1 and 2 (odds ratio, 4.28; 95% confidence interval, 1.79-10.20; P < .01). Smokers were more prone to surgical complications than nonsmokers (odds ratio, 5.08; 95% confidence interval, 1.96-13.11; P = .02). CONCLUSION Surgical complication rates after anatomic total shoulder arthroplasty in patients with primary osteoarthritis correlate with the patient's overall health status and nicotine consumption. This may be useful for predicting the likelihood of surgical complications and may thus prove important for clinicians to better assess and explain possible risks before surgery.
Collapse
Affiliation(s)
- Tim Leschinger
- Center for Orthopedic and Trauma Surgery, University Medical Center of Cologne, Germany.
| | - Patric Raiss
- Clinic for Orthopedics and Trauma Surgery, University of Heidelberg, Heidelberg, Germany
| | - Markus Loew
- Shoulder and Elbow Surgery, ATOS Clinic Heidelberg, Heidelberg, Germany
| | - Felix Zeifang
- Clinic for Orthopedics and Trauma Surgery, University of Heidelberg, Heidelberg, Germany
| |
Collapse
|
30
|
Seagrave KG, Troelsen A, Malchau H, Husted H, Gromov K. Acetabular cup position and risk of dislocation in primary total hip arthroplasty. Acta Orthop 2017; 88:10-17. [PMID: 27879150 PMCID: PMC5251254 DOI: 10.1080/17453674.2016.1251255] [Citation(s) in RCA: 146] [Impact Index Per Article: 20.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Hip dislocation is one of the most common complications following total hip arthroplasty (THA). Several factors that affect dislocation have been identified, including acetabular cup positioning. Optimal values for cup inclination and anteversion are debatable. We performed a systematic review to describe the different methods for measuring cup placement, target zones for cup positioning, and the association between cup positioning and dislocation following primary THA. Methods - A systematic search of literature in the PubMed database was performed (January and February 2016) to identify articles that compared acetabular cup positioning and the risk of dislocation. Surgical approach and methods for measurement of cup angles were also considered. Results - 28 articles were determined to be relevant to our research question. Some articles demonstrated that cup positioning influenced postoperative dislocation whereas others did not. The majority of articles could not identify a statistically significant difference between dislocating and non-dislocating THA with regard to mean angles of cup anteversion and inclination. Most of the articles that assessed cup placement within the Lewinnek safe zone did not show a statistically significant reduction in dislocation rate. Alternative target ranges have been proposed by several authors. Interpretation - The Lewinnek safe zone could not be justified. It is difficult to draw broad conclusions regarding a definitive target zone for cup positioning in THA, due to variability between studies and the likely multifactorial nature of THA dislocation. Future studies comparing cup positioning and dislocation rate should investigate surgical approach separately. Standardized tools for measurement of cup positioning should be implemented to allow comparison between studies.
Collapse
Affiliation(s)
- Kurt G Seagrave
- Faculty of Medicine, University of New South Wales, Sydney, Australia,Department of Orthopaedic Surgery, Copenhagen University Hospital Hvidovre. Copenhagen, Denmark
| | - Anders Troelsen
- Department of Orthopaedic Surgery, Copenhagen University Hospital Hvidovre. Copenhagen, Denmark
| | - Henrik Malchau
- Harris Orthopaedic Laboratory, Massachusetts General Hospital,Department of Orthopaedic Surgery, Harvard Medical School, Boston, MA, USA
| | - Henrik Husted
- Department of Orthopaedic Surgery, Copenhagen University Hospital Hvidovre. Copenhagen, Denmark
| | - Kirill Gromov
- Department of Orthopaedic Surgery, Copenhagen University Hospital Hvidovre. Copenhagen, Denmark,Correspondence:
| |
Collapse
|
31
|
Falez F, Papalia M, Favetti F, Panegrossi G, Casella F, Mazzotta G. Total hip arthroplasty instability in Italy. INTERNATIONAL ORTHOPAEDICS 2016; 41:635-644. [PMID: 27999925 DOI: 10.1007/s00264-016-3345-6] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2016] [Accepted: 11/09/2016] [Indexed: 01/25/2023]
Abstract
Hip dislocation is a major and common complication of total hip arthroplasty (THA), which appears with an incidence between 0.3% and 10% in primary total hip arthroplasties and up to 28% in revision THA. The hip dislocations can be classified into three groups: early, intermediate and late. Approximately two-thirds of cases can be treated successfully with a non-operative approach. The rest require further surgical intervention. The prerequisite to developing an appropriate treatment strategy is a thorough evaluation to identify the causes of the dislocation. In addition, many factors that contribute to THA dislocation are related to the surgical technique, mainly including component orientation, femoral head diameter, restoration of femoral offset and leg length, cam impingement and condition of the soft tissues. The diagnosis of a dislocated hip is relatively easy because the clinical situation is very typical. Having identified a dislocated hip, the first step is to perform a closed reduction of the implant. After reduction you must perform a computed tomography scan to evaluate the surgical options for treatment of recurrent dislocation that include: revision arthroplasty, modular components exchange, dual-mobility cups, large femoral heads, constrained cups, elimination of impingement and soft tissue procedures. The objective is to avoid further dislocation, a devastating event which is increasing the number of operations on the hip. To obtain this goal is useful to follow an algorithm of treatment, but the best treatment remains prevention.
Collapse
Affiliation(s)
- Francesco Falez
- Orthopaedic and Traumatology Department, S. Spirito Hospital, Lungotevere in Sassia,1, Rome, Italy.
| | - Matteo Papalia
- Orthopaedic and Traumatology Department, Nuova Itor Clinic, Rome, Italy
| | - Fabio Favetti
- Orthopaedic and Traumatology Department, S. Spirito Hospital, Lungotevere in Sassia,1, Rome, Italy
| | - Gabriele Panegrossi
- Orthopaedic and Traumatology Department, S. Spirito Hospital, Lungotevere in Sassia,1, Rome, Italy
| | - Filippo Casella
- Orthopaedic and Traumatology Department, S. Spirito Hospital, Lungotevere in Sassia,1, Rome, Italy
| | - Gianluca Mazzotta
- Orthopaedic and Traumatology Department, S. Spirito Hospital, Lungotevere in Sassia,1, Rome, Italy
| |
Collapse
|
32
|
Jauregui JJ, Banerjee S, Elmallah RK, Pierce TP, Cherian JJ, Harwin SF, Mont MA. Radiographic Evaluation of Hip Dislocations Necessitating Revision Total Hip Arthroplasty. Orthopedics 2016; 39:e1011-8. [PMID: 27337666 DOI: 10.3928/01477447-20160616-02] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/10/2015] [Accepted: 08/19/2015] [Indexed: 02/03/2023]
Abstract
Although prosthetic hip dislocation is a common reason for revision arthroplasty, few studies have comprehensively evaluated the radiographic factors that may lead to the need for revision. Therefore, the authors radiographically evaluated all prosthetic hip dislocations that were treated at one institution. They then specifically assessed those that required revision surgery. The authors found that the prosthetic center of rotation (pCOR) was located superolateral and inferolateral to the native COR (nCOR) in all patients. Most hips had pCOR distances more than 5 mm from the nCOR. Furthermore, most patients had cup inclination and anteversion angles within Lewinnek's previously defined "safe zone." Determining these similarities and properly planning these procedures may help decrease the instability rate and therefore improve the overall success of this procedure. [Orthopedics.2016; 39(5):e1011-e1018.].
Collapse
|
33
|
Abstract
Dual mobility cups have two points of articulation, one between the shell and the polyethylene (external bearing) and one between the polyethylene and the femoral head (internal bearing). Movement occurs at the inner bearing; the outer bearing only moves at extremes of movement. Dislocation after total hip arthroplasty (THA) is a cause of much morbidity and its treatment has significant cost implications. Dual mobility cups provide an increased range of movement and a may reduce the risk of dislocation. This paper reviews the use of these cups in THA, particularly where stability is an issue. Dual mobility cups may be of benefit in primary THA in patients at a high risk of dislocation, such as those who are older with increased comorbidities and a higher American Association of Anesthesiology grade and those with a neuromuscular disease. They may be used at revision surgery where the risk of dislocation is high, such as in patients with many prior dislocations, or those with abductor deficiency. They may also be used in THA for displaced fractures of the femoral neck, which has a notoriously high rate of dislocation.
Collapse
Affiliation(s)
- L Matsen Ko
- Rothman Institute Orthopaedics, Egg Harbor Township, New Jersey, 08234, USA
| | - W J Hozack
- Rothman Institute Orthopaedics, Egg Harbor Township, New Jersey, 08234, USA
| |
Collapse
|
34
|
Lee YK, Ha YC, Jo WL, Kim TY, Jung WH, Koo KH. Could larger diameter of 4th generation ceramic bearing decrease the rate of dislocation after THA? J Orthop Sci 2016; 21:327-31. [PMID: 26876620 DOI: 10.1016/j.jos.2016.01.002] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/16/2015] [Revised: 12/15/2015] [Accepted: 01/07/2016] [Indexed: 02/09/2023]
Abstract
BACKGROUND Fourth generation (Delta) ceramic bearing was developed to reduce dislocation after total hip arthroplasty (THA) by increasing the head diameter. We tested a hypothesis that 32/36 mm Delta ceramic bearing decreases the dislocation rate. We also evaluated ceramic-related complications and early outcome of this thin liner-on-large head ceramic bearing. METHODS We performed a prospective study on patients who underwent THA with use of 32/36 mm Delta ceramic bearing. The dislocation rate was compared with the historical dislocation rate of third generation 28 mm ceramic bearing. We also evaluated ceramic fracture, squeak, short-term results and survival. Follow-up period was minimum 2 years. RESULTS Between April 2010 and February 2012, we enrolled 250 consecutive patients (278 hips). All patients received cementless prostheses. Four patients (4 hips) who received metal shells ≤ 46 mm and 28 mm heads were excluded. Three patients died and 2 patients were lost within 2 years. The remaining 241 patients (269 hips) were followed for 24-46 months. There were 142 men (161 hips) and 99 women (108 hips) with a mean age of 53.7 years (range, 17-75 years) at the index operation. Dislocation occurred in three hips (1.1%). An old age was a risk factor for dislocation. Ceramic fracture and squeaking did not occur in any patient. Mean Harris hip score was 90.3 points at the latest follow-up. All acetabular and femoral components had bone-ingrowth stability. No hip had detectable wear or osteolysis. The survival was 99.3% in the best case scenario and 97.8% in the worst at 48 months. CONCLUSIONS Total hip arthroplasty with use of 32/36 mm Delta ceramic bearing showed lower incidence of hip dislocation compared with 28 mm third generation ceramic bearing. A caution should be paid to prevent a fall in senile patients even though a large head is used. The short-term results of THA with this type of ceramic articulation are encouraging and we did not find any ceramic-related complications.
Collapse
Affiliation(s)
- Young-Kyun Lee
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea
| | - Yong-Chan Ha
- Department of Orthopaedic Surgery, Chung-Ang University College of Medicine, Seoul, South Korea.
| | - Woo-Lam Jo
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea
| | - Tae-Young Kim
- Department of Orthopaedic Surgery, Hallym University Sacred Heart Hospital, Anyang, South Korea
| | - Woon-Hwa Jung
- Department of Orthopaedic Surgery, Murup Hospital, Masan, South Korea
| | - Kyung-Hoi Koo
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea
| |
Collapse
|
35
|
Capón-García D, López-Pardo A, Alves-Pérez M. Causes for revision surgery in total hip replacement. A retrospective epidemiological analysis. Rev Esp Cir Ortop Traumatol (Engl Ed) 2016. [DOI: 10.1016/j.recote.2016.03.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
36
|
Capón-García D, López-Pardo A, Alves-Pérez MT. Causes for revision surgery in total hip replacement. A retrospective epidemiological analysis. Rev Esp Cir Ortop Traumatol (Engl Ed) 2016; 60:160-6. [PMID: 26944512 DOI: 10.1016/j.recot.2016.01.002] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2015] [Revised: 01/10/2016] [Accepted: 01/20/2016] [Indexed: 12/01/2022] Open
Abstract
OBJECTIVE To determine the impact of each cause of revision surgery in total hip arthroplasty during the period 2009-2013. To analyse the relationship between these causes with different variables. MATERIALS AND METHODS A study was conducted on 127 patients who had hip replacement revision surgery in our hospital during this period. Parameters, such as age, sex, date of primary arthroplasty, prosthetic replacement date, and main cause of the revision were recorded. Those revisions performed within 5 years after the primary arthroplasty were considered as early rescue. RESULTS The most common cause of rescue was aseptic loosening in 38 (30%) followed by instability in 30 (24%). In terms of age at the time of rescue, statistically significant differences were found, with it being significantly higher in patients re-operated for a fracture. Differences in age at first surgery were found to be 7 years younger than those with late rescue (63.40) with respect to early (70.21). DISCUSSION Similar results to ours have been observed in other published series, except for the higher incidence of instability in early rescue. CONCLUSIONS This study demonstrates aseptic loosening and instability as the most frequent causes of revision surgery in our hospital. Age is a very influential factor in relation to longevity of primary arthroplasty. Complications were higher in when the primary hip replacement is implanted in older patients.
Collapse
Affiliation(s)
- D Capón-García
- Servicio de Cirugía Ortopédica y Traumatología, Hospital Universitario Lucus Augusti, Lugo, España.
| | - A López-Pardo
- Servicio de Cirugía Ortopédica y Traumatología, Hospital Universitario Lucus Augusti, Lugo, España
| | - M T Alves-Pérez
- Grupo NECOM-Neurocomunicación y Marketing, Universidade de Vigo, Vigo, España
| |
Collapse
|
37
|
Haughom BD, Plummer DR, Moric M, Della Valle CJ. Is There a Benefit to Head Size Greater Than 36 mm in Total Hip Arthroplasty? J Arthroplasty 2016; 31:152-5. [PMID: 26360768 DOI: 10.1016/j.arth.2015.08.011] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/18/2015] [Revised: 07/26/2015] [Accepted: 08/06/2015] [Indexed: 02/09/2023] Open
Abstract
This study compares the rate of dislocation and revision for instability between 36-mm and anatomic femoral heads (large diameter metal-on-metal THA, dual-mobility bearings, and hip resurfacing arthroplasty) in patients at high risk for dislocation. A total of 501 high-risk patients, over a 10-year period, were identified (282 36-mm THA, 24 dual-mobility bearings, 83 metal-on-metal arthroplasty, and 112 hip resurfacing arthroplasty). There were 13 dislocations in the 36-mm group compared to 1 in the anatomic group (4.6% vs 0.5%; P = .005). Four patients dislocated more than once in the 36-mm group (1.4% vs 0%; P = .04), and 2 patients in the 36-mm group required a revision for instability (0.7% vs 0%; P = .11). These results suggest that anatomic head sizes significantly lower the risk of dislocation in high-risk patients.
Collapse
Affiliation(s)
| | | | - Mario Moric
- Rush University Medical Center, Chicago, Illinois
| | | |
Collapse
|
38
|
Canham CD, Yen YM, Giordano BD. Does Femoroacetabular Impingement Cause Hip Instability? A Systematic Review. Arthroscopy 2016; 32:203-8. [PMID: 26427629 DOI: 10.1016/j.arthro.2015.07.021] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2015] [Revised: 06/22/2015] [Accepted: 07/24/2015] [Indexed: 02/02/2023]
Abstract
PURPOSE To determine whether femoroacetabular impingement (FAI) is associated with hip instability. METHODS A systematic search examining FAI and hip instability was conducted according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Clinical and basic science studies were included. Instability had to be documented with either a clinical or imaging examination. Studies were excluded if they did not define diagnostic criteria for FAI, involved prosthetic hips, were not in English, were review articles, or reported Level V evidence (case reports, expert opinion). Rates of FAI morphologic features in patients with documented hip instability were determined. Mechanisms and rates of FAI-induced hip subluxation were examined in basic science studies. RESULTS The search yielded 1,630 relevant studies. Seven studies (4 clinical and 3 basic science) met inclusion criteria. Four studies investigated an association between FAI and hip instability in 92 patients with an average age of 31 years. Seventy-six patients experienced frank dislocations and 16 experienced posterior subluxation events. The prevalence of FAI was documented in 89 patients with hip instability. The rates of cam and pincer morphologic characteristics were 74% and 64%, respectively. The average lateral center edge angle and prevalence of acetabular retroversion were 30° and 70%, respectively (n = 76 patients). All 3 basic science studies had real-time visualization of FAI-induced hip subluxations. CONCLUSIONS High rates of FAI morphologic characteristics are present in patients with hip instability. FAI morphologic characteristics may predispose the hip to instability through anatomic conflict caused by pincer or cam lesions (or both) levering the femoral head posteriorly. LEVEL OF EVIDENCE Level IV, systematic review of Level III, Level IV, and non-clinical studies.
Collapse
Affiliation(s)
- Colin D Canham
- Division of Sports Medicine, Department of Orthopaedics and Rehabilitation, Hip Preservation Program, University of Rochester Medical Center, Rochester, New York, U.S.A
| | - Yi-Meng Yen
- Boston Children's Hospital, Boston, Massachusetts, U.S.A
| | - Brian D Giordano
- Division of Sports Medicine, Department of Orthopaedics and Rehabilitation, Hip Preservation Program, University of Rochester Medical Center, Rochester, New York, U.S.A..
| |
Collapse
|
39
|
Lin HC, Chi WM, Ho YJ, Lin CC, Chen JH. Theoretical Analysis of Total Hip Dislocation and Comparison of Hemispherical Cup and Newly Developed Cup. J Med Biol Eng 2015. [DOI: 10.1007/s40846-015-0073-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
40
|
Ezquerra-Herrando L, Seral-García B, Quilez M, Pérez M, Albareda-Albareda J. Instability of total hip replacement: A clinical study and determination of its risk factors. Rev Esp Cir Ortop Traumatol (Engl Ed) 2015. [DOI: 10.1016/j.recote.2015.04.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
|
41
|
Billaud A, Verdier N, de Bartolo R, Lavoinne N, Chauveaux D, Fabre T. Acetabular component navigation in lateral decubitus based on EOS imaging: A preliminary study of 13 cases. Orthop Traumatol Surg Res 2015; 101:271-5. [PMID: 25842249 DOI: 10.1016/j.otsr.2015.01.010] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/20/2013] [Revised: 12/30/2014] [Accepted: 01/27/2015] [Indexed: 02/02/2023]
Abstract
INTRODUCTION Acetabular component navigation classically requires palpation of the bone landmarks defining the anterior pelvic plane (APP) (anterior superior iliac spine [ASIS] and pubis), the recording of which is not very reliable when performed in lateral decubitus. The objectives of the current experimental study were: (1) to assess the clinical feasibility of NAVEOS navigation (based on EOS imaging) in lateral decubitus; and (2) to compare precision versus classical APP-based navigation (NAVAPP). HYPOTHESIS Iliac plane navigation using EOS is as reliable as APP navigation. PATIENTS AND METHODS A continuous prospective series of 13 total hip replacements were implanted in lateral decubitus under APP-guided navigation (NAVAPP). Planning used preoperative EOS measurement. The ASIS, pubis and ipsilateral posterior superior iliac spine (PSIS) were located and exported to the navigator. Intra-operatively, NAVEOS landmarks (acetabular center, ASIS and PSIS on the operated side) were palpated. Postoperatively, cup inclination and anteversion with respect to the APP were measured on EOS imaging (SterEOS3D software). The SterEOS3D measurements were compared to those of the performed NAVAPP and simulated NAVEOS navigations. RESULTS Three patients were excluded for technical reasons. In the remaining 10, inclination on NAVAPP and SterEOS3D differed by a median 4° (range, 0-12°), and on NAVEOS versus SteEOS3D by 5° (range, 2-10°); anteversion on NAVAPP and SterEOS3D differed by a median 4.5° (range, 0-12°), and on NAVEOS versus SteEOS3D by 4° (range, 0-14°). CONCLUSION Precision was comparable between NAVEOS and classical navigation. NAVEOS simplifies cup navigation in lateral decubitus on initial acquisition. These results require validation on a larger sample.
Collapse
Affiliation(s)
- A Billaud
- Pôle d'orthopédie, hôpital Pellegrin, CHU de Bordeaux, place Amélie-Raba-Léon, 33000 Bordeaux, France.
| | - N Verdier
- Pôle d'orthopédie, hôpital Pellegrin, CHU de Bordeaux, place Amélie-Raba-Léon, 33000 Bordeaux, France
| | - R de Bartolo
- Pôle d'orthopédie, hôpital Pellegrin, CHU de Bordeaux, place Amélie-Raba-Léon, 33000 Bordeaux, France
| | - N Lavoinne
- Pôle d'orthopédie, hôpital Pellegrin, CHU de Bordeaux, place Amélie-Raba-Léon, 33000 Bordeaux, France
| | - D Chauveaux
- Pôle d'orthopédie, hôpital Pellegrin, CHU de Bordeaux, place Amélie-Raba-Léon, 33000 Bordeaux, France
| | - T Fabre
- Pôle d'orthopédie, hôpital Pellegrin, CHU de Bordeaux, place Amélie-Raba-Léon, 33000 Bordeaux, France
| |
Collapse
|
42
|
Ezquerra-Herrando L, Seral-García B, Quilez MP, Pérez MA, Albareda-Albareda J. Instability of total hip replacement: A clinical study and determination of its risk factors. Rev Esp Cir Ortop Traumatol (Engl Ed) 2015; 59:287-94. [PMID: 25650080 DOI: 10.1016/j.recot.2014.12.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2014] [Revised: 12/01/2014] [Accepted: 12/03/2014] [Indexed: 10/24/2022] Open
Abstract
OBJECTIVES To determine the risk factors associated with prosthetic dislocation and simulate a finite element model to determine the safe range of movement of various inclination and anteversion cup positions. MATERIAL AND METHODS Retrospective Case Control study with 46 dislocated patients from 1994 to 2011. CONTROL GROUP 83 randomly selected patients. Dislocation risk factors described in the literature were collected. A prosthetic model was simulated using finite elements with 28, 32, 36 mm heads, and a 52 mm cup. Acetabular position was 25°, 40°, and 60° tilt and with 0°, 15° and 25° anteversion. In extension of 0° and flexion of 90°, internal and external rotation was applied to analyze the range of movement, maximum resisting moment, and stress distribution in the acetabulum to impingement and dislocation. RESULTS There was greater dislocation in older patients (p=0.002). Higher dislocation in fractures than in osteoarthritis (p=0.001). Less anteversion in dislocated patients (p=0.043). Longer femoral neck in dislocated patients (p=0.002). Finite element model: lower dislocation when there is more anteversion, tilt and bigger femoral heads. DISCUSSION-CONCLUSIONS Advanced age and fractures are the major risk factors for dislocation. "Safe zone" of movement for dislocation avoidance is 40°-60° tilt and 15°-25° anteversion. Both the defect and excess of soft tissue tension predispose to dislocation. Bigger femoral heads are more stable.
Collapse
Affiliation(s)
- L Ezquerra-Herrando
- Servicio de Cirugía Ortopédica y Traumatología, Hospital Clínico Universitario Lozano Blesa, Zaragoza, España.
| | - B Seral-García
- Servicio de Cirugía Ortopédica y Traumatología, Hospital Clínico Universitario Lozano Blesa, Zaragoza, España
| | - M P Quilez
- Instituto Universitario de Investigación en Ingeniería de Aragón (I3A), Universidad de Zaragoza, Zaragoza, España
| | - M A Pérez
- Instituto Universitario de Investigación en Ingeniería de Aragón (I3A), Universidad de Zaragoza, Zaragoza, España
| | - J Albareda-Albareda
- Servicio de Cirugía Ortopédica y Traumatología, Hospital Clínico Universitario Lozano Blesa, Zaragoza, España
| |
Collapse
|
43
|
Guenoun B, El Hajj F, Biau D, Anract P, Courpied JP. Reliability of a new method for evaluating femoral stem positioning after total hip arthroplasty based on stereoradiographic 3D reconstruction. J Arthroplasty 2015; 30:141-4. [PMID: 25161165 DOI: 10.1016/j.arth.2014.07.033] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/29/2014] [Revised: 07/12/2014] [Accepted: 07/28/2014] [Indexed: 02/01/2023] Open
Abstract
The goal of this study was to validate a new method for determining femoral stem positioning based on 3D models derived from the EOS biplanar system. Independents observers measured stem anteversion and femoral offset using CT scan and EOS system of 28 femoral stems implanted in composite femurs. In parallel, the same parameters were measured on biplanar lower limb radiographs acquired from 30 patients who had undergone total hip arthroplasty. CT scanner and biplanar X-ray measurements on composite femurs were highly correlated: 0.94 for femoral offset (P < 0.01), 0.98 for stem anteversion (P < 0.01). The inter and intra-observer reproducibility when measuring composite bones was excellent with both imaging modalities as when measuring femoral stem positioning in patients with the biplanar X-ray system.
Collapse
Affiliation(s)
| | - Firass El Hajj
- Service de Chirurgie Orthopédique et Traumatologique - Groupe Hospitalier Cochin - Port-Royal (AP-HP), Paris, France
| | - David Biau
- Service de Chirurgie Orthopédique et Traumatologique - Groupe Hospitalier Cochin - Port-Royal (AP-HP), Paris, France
| | - Philippe Anract
- Service de Chirurgie Orthopédique et Traumatologique - Groupe Hospitalier Cochin - Port-Royal (AP-HP), Paris, France
| | - Jean-Pierre Courpied
- Service de Chirurgie Orthopédique et Traumatologique - Groupe Hospitalier Cochin - Port-Royal (AP-HP), Paris, France
| |
Collapse
|
44
|
Risk factors for total hip arthroplasty dislocation and its functional outcomes. Rev Esp Cir Ortop Traumatol (Engl Ed) 2015. [DOI: 10.1016/j.recote.2014.11.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
45
|
Obesity is no longer a risk factor for dislocation after total hip arthroplasty with a double-mobility cup. INTERNATIONAL ORTHOPAEDICS 2014; 39:1251-8. [DOI: 10.1007/s00264-014-2612-7] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2014] [Accepted: 11/21/2014] [Indexed: 12/19/2022]
|
46
|
Abstract
BACKGROUND Luxation following endoprosthetic hip replacement represents a frequent and severe complication and is the reason for a relevant number of hip arthroplasty revision interventions. The probability of occurrence of luxation of a total hip arthroplasty is associated with the indications, patient and operation-specific risk factors. Approximately 50 % of luxations after total hip arthroplasty occur within 3 months of the operation (early luxation). DIAGNOSTICS The diagnostics of luxation of total hip arthroplasty are carried out by clinical and radiological methods. The causative assignment is made by assessment of joint stability, the bony situation (e.g. loosening, periprosthetic fracture and defects) and the soft tissue (e.g. pelvitrochanterian musculature). In cases of clinical and paraclinical signs of infection and of late luxations, a joint puncture is indicated. THERAPY Therapy decisions are made depending on the cause (e.g. implant malpositioning, pelvitrochanterian insufficiency, impingement, incongruence between head and inlay and combinations of causes). Therapy of acute total hip prosthesis luxation begins with imaging controlled repositioning carried out with the patient under adequate analgesia and sedation. Conservative therapy is carried out by immobilization with a hip joint orthesis or pelvis-leg cast for 6 weeks. Operative therapy strategies for recurrent luxation are restoration of the correct implant position and sufficient soft tissue tension. Larger hip heads, bipolar heads and tripolar cups are more commonly used due to the geometrically lower probability of dislocation (higher jumping distance). Luxation of total hip prostheses due to infection is treated according to the principles of periprosthetic infection therapy. The rate of recurrence of luxation of 30 % is high so that in cases of unsuccessful therapy treatment should best be carried out in a center for revision arthroplasty. CONCLUSIONS The search for the exact cause of total hip prosthesis luxation is extremely important. A classification is only possible when the exact cause is known and together with patient and implant-specific details the therapeutic approach can be ascertained. In revision operations the intraoperative functional diagnostics must be exactly documented. The reasons for delayed luxations could be prosthesis infections, abrasion and loosening.
Collapse
|
47
|
[Risk factors for total hip arthroplasty dislocation and its functional outcomes]. Rev Esp Cir Ortop Traumatol (Engl Ed) 2014; 59:19-25. [PMID: 25048273 DOI: 10.1016/j.recot.2014.05.005] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2013] [Revised: 07/29/2013] [Accepted: 05/29/2014] [Indexed: 11/23/2022] Open
Abstract
OBJECTIVES To evaluate risk factors for dislocation after primary total hip arthroplasty (THA), and its functional outcomes. MATERIAL AND METHODS A retrospective study was conducted on 22 cases with dislocation and 431 controls without dislocation, all performed with lateral access. The data were collected prospectively with a minimum follow-up of 5 years. Patient related factors, from primary surgery, and position of components on simple radiographs were analyzed. Harris and Merle D'Aubigné hip scores, and short Womac questionnaire were used. RESULTS Demographic, patient-related or surgical technique factors were not risk predictors of dislocation. With regard to position of components, an acetabular abduction >50° (p = 0.003) and anteversion lower or higher than 10°- 20° (p = 0.044) were risk factors. Controls and dislocation treated conservatively had similar outcomes, and in both were better than in those treated with surgical revision (p = 0.03). DISCUSSION Factors relating to the patient and soft tissues status may influence the stability of the arthroplasty, but malposition of the acetabular component seems to be the most important and common risk factor for dislocation.
Collapse
|
48
|
Johnson CC, Sodha S, Garzon-Muvdi J, Petersen SA, McFarland EG. Does preoperative American Society of Anesthesiologists score relate to complications after total shoulder arthroplasty? Clin Orthop Relat Res 2014; 472:1589-96. [PMID: 24323687 PMCID: PMC3971223 DOI: 10.1007/s11999-013-3400-1] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/16/2013] [Accepted: 11/19/2013] [Indexed: 01/31/2023]
Abstract
BACKGROUND For hip and knee arthroplasties, an American Society of Anesthesiologists (ASA) score greater than 2 is associated with an increased risk of medical and surgical complications. No study, to our knowledge, has evaluated this relationship for total shoulder arthroplasty (TSA) or reverse total shoulder arthroplasty (reverse TSA). QUESTIONS/PURPOSES We aimed to assess the relationship between the ASA score and (1) surgical complications, (2) medical complications, and (3) hospitalization length after TSA, reverse TSA, and revision arthroplasty. METHODS We retrospectively analyzed all patients who had undergone TSAs, reverse TSAs, or revision arthroplasties by the senior author (EGM) from November 1999 through July 2011 who had at least 6 months' followup. Of the 485 procedures, 452 (93.2%) met the inclusion criteria. Data were collected on patient demographics, comorbidities, hospitalization length, and short-term (≤ 6 months) medical and surgical complications. Logistic regression analysis modeled the risk of having postoperative complications develop as a function of the ASA score. RESULTS Patients with an ASA score greater than 2 had a greater risk of having a surgical complication develop (p < 0.001; OR, 2.27; 95% CI, 1.36-3.70) and three times the risk of prosthesis failure (ie, component dislocation, component loosening, and hardware failure) (p < 0.001; OR, 3.23; 95% CI, 1.54-6.67). Higher ASA scores were associated with prolonged length of hospitalization (effect size 0.46, p < 0.001), but not medical complications. CONCLUSIONS ASA score is associated with surgical, but not medical, complications after TSA and reverse TSA. The ASA score could be used for risk assessment and preoperative counseling. LEVEL OF EVIDENCE Level III, therapeutic study. See the Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Christine C. Johnson
- />Division of Shoulder Surgery, Department of Orthopaedic Surgery, The Johns Hopkins University, Baltimore, MD USA
| | - Sonal Sodha
- />Division of Shoulder Surgery, Department of Orthopaedic Surgery, The Johns Hopkins University, Baltimore, MD USA
| | - Juan Garzon-Muvdi
- />Division of Shoulder Surgery, Department of Orthopaedic Surgery, The Johns Hopkins University, Baltimore, MD USA
| | - Steve A. Petersen
- />Division of Shoulder Surgery, Department of Orthopaedic Surgery, The Johns Hopkins University, Baltimore, MD USA
| | - Edward G. McFarland
- />Division of Shoulder Surgery, Department of Orthopaedic Surgery, The Johns Hopkins University, Baltimore, MD USA , />c/o Elaine P. Henze, BJ, ELS, Medical Editor and Director, Editorial Services, Department of Orthopaedic Surgery, The Johns Hopkins University/Johns Hopkins Bayview Medical Center, 4940 Eastern Avenue, #A672, Baltimore, MD 21224-2780 USA
| |
Collapse
|
49
|
Zhang J, Wang L, Mao Y, Li H, Ding H, Zhu Z. The use of combined anteversion in total hip arthroplasty for patients with developmental dysplasia of the hip. J Arthroplasty 2014; 29:621-5. [PMID: 24029717 DOI: 10.1016/j.arth.2013.08.004] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/14/2013] [Revised: 08/05/2013] [Accepted: 08/05/2013] [Indexed: 02/07/2023] Open
Abstract
The combined anteversion technique has been proposed recently and proved to be an applicable technique in general THA. The corresponding author routinely applied this approach to DDH patients in clinical practice. The current study aimed to provide clinical evidence for this approach. We studied 35 DDH patients (47 hips). Every patient underwent pelvic CT scans before and after surgery and the HHs was recorded. The data indicate a high accuracy of controlling components orientation and satisfactory clinical outcomes. Using this approach, we reduced dislocation risk and got better impingement free range of motion. Therefore, we conclude that combined anteversion is effective for DDH patients who receive a THA. This approach could guarantee stable and functioning joints for DDH patients receiving THA.
Collapse
Affiliation(s)
- Jingwei Zhang
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, P.R. China
| | - Liao Wang
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, P.R. China
| | - Yuanqing Mao
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, P.R. China
| | - Huiwu Li
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, P.R. China
| | - Huifeng Ding
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, P.R. China
| | - Zhenan Zhu
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, P.R. China
| |
Collapse
|
50
|
Charissoux JL, Asloum Y, Marcheix PS. Surgical management of recurrent dislocation after total hip arthroplasty. Orthop Traumatol Surg Res 2014; 100:S25-34. [PMID: 24434366 DOI: 10.1016/j.otsr.2013.11.008] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/20/2013] [Revised: 06/18/2013] [Accepted: 11/06/2013] [Indexed: 02/02/2023]
Abstract
Dislocation is a major complication of total hip arthroplasty (THA), whose frequency has been unaffected by improvements in surgical techniques and implants. The dislocation rate depends on multiple factors related to the patient, hip disease, and surgical procedure and is therefore also dependent on the surgeon. The many published studies on THA dislocation, its causes, and its treatment have produced conflicting results. The objective of this work is to review the management of THA dislocation, which is a severe event for both the patient and the surgeon. This lecture starts with a brief review of data on THA dislocation rates and the many factors that influence them. Emphasis is then put on the evaluation for a cause and, more specifically, on the challenges raised by detecting suboptimal cup position. Next, reported techniques for treating THA dislocation and the outcomes of each are discussed. Finally, a management strategy for patients selected for revision surgery is suggested.
Collapse
Affiliation(s)
- J-L Charissoux
- Service d'orthopedie traumatologie, CHU Dupuytren, 2, avenue Martin-Luther-King, 87042 Limoges cedex, France.
| | - Y Asloum
- Service d'orthopedie traumatologie, CHU Dupuytren, 2, avenue Martin-Luther-King, 87042 Limoges cedex, France
| | - P-S Marcheix
- Service d'orthopedie traumatologie, CHU Dupuytren, 2, avenue Martin-Luther-King, 87042 Limoges cedex, France
| |
Collapse
|