1
|
Motomura G, Mashima N, Imai H, Sudo A, Hasegawa M, Yamada H, Morita M, Mitsugi N, Nakanishi R, Nakashima Y. Effects of porous tantalum on periprosthetic bone remodeling around metaphyseal filling femoral stem: a multicenter, prospective, randomized controlled study. Sci Rep 2022; 12:914. [PMID: 35042918 PMCID: PMC8766592 DOI: 10.1038/s41598-022-04936-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Accepted: 11/23/2021] [Indexed: 11/09/2022] Open
Abstract
Periprosthetic bone loss due to adaptive bone remodeling is an important unresolved issue in cementless total hip arthroplasty (THA). The use of porous tantalum on the proximal surface of the femoral stem is expected to decrease postoperative bone loss around the prosthesis through early fixation. We conducted a multicenter randomized controlled study to determine if porous tantalum could reduce periprosthetic bone loss after THA. From October 2012 to September 2014, 118 patients (mean age, 61.5 years; 107 females and 11 males) were prospectively enrolled and were randomly allocated at a ratio of 1:1 to either a metaphyseal filling stem with a proximal porous tantalum coating (Trabecular Metal) or a conventional metaphyseal filling stem with fiber mesh coating (VerSys). Patients underwent dual-energy x-ray absorptiometry scans within 1 week after surgery (baseline) and at 6, 12, and 24 months after surgery to assess periprosthetic bone mineral density (BMD) in the 7 Gruen zones. In addition, the Japanese Orthopaedic Association hip score was assessed before surgery and at 6, 12, and 24 months after surgery. In the proximal periprosthetic region (zones 1 and 7), the Trabecular Metal group had significantly smaller reductions in BMD than the VerSys group throughout the study period. In the VerSys group, significant reductions in BMD compared to baseline were seen at each measurement point in all regions, except in zone 6 at 24 months. In the Trabecular Metal group, no significant reductions in BMD relative to baseline were seen in zones 1, 5, or 6 throughout the study period. Both groups demonstrated similar improvement in Japanese Orthopaedic Association hip scores over the study period. This study demonstrated that a proximally coated stem with porous tantalum has superior results over a conventional stem with titanium fiber mesh in terms of periprosthetic bone remodeling.
Collapse
Affiliation(s)
- Goro Motomura
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan
| | - Naohiko Mashima
- Department of Regeneration of Community Medicine, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, 791-0295, Japan
| | - Hiroshi Imai
- Department of Orthopaedic Surgery, Graduate School of Medicine, Ehime University, Shitsukawa, Toon, 791-0295, Japan
| | - Akihiro Sudo
- Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, 2-174 Edobashi, Tsu City, Mie, 514-8507, Japan
| | - Masahiro Hasegawa
- Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, 2-174 Edobashi, Tsu City, Mie, 514-8507, Japan
| | - Harumoto Yamada
- Department of Orthopaedic Surgery, Fujita Health University, Toyoake, Aichi, 470-1192, Japan.,Department of Orthopedic Surgery, Nisshin Orido Hospital, 110, Nishidamen, Orido-cho, Nisshin, Aichi, 470-0115, Japan
| | - Mitsuhiro Morita
- Department of Orthopaedic Surgery, Fujita Health University, Toyoake, Aichi, 470-1192, Japan
| | - Naoto Mitsugi
- Department of Orthopedic Surgery, Yokohama City University Medical Center, 4-57, Urafune-cho, Minami, Yokohama, Kanagawa, 232-0024, Japan.,Department of Orthopedic Surgery, Osada Hospital, 2-10, Maruyamadai, Minatominami-ku, Yokohama, Kanagawa, 233-0013, Japan
| | - Ryosuke Nakanishi
- Department of Orthopaedic Surgery, Showa University Fujigaoka Hospital, Showa University School of Medicine, 1-30 Fujigaoka Aobaku, Yokohama, 227-8501, Japan.,Department of Orthopedic Surgery, Shizuoka Medical Center, 762-1, Nagasawa, Shimizu-cho, Sunto District, Shizuoka, 411-8611, Japan
| | - Yasuharu Nakashima
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
| |
Collapse
|
2
|
Levadnyi I, Gubaua JE, Dicati GWO, Awrejcewicz J, Gu Y, Pereira JT, Loskutov A. Comparative Analysis of the Biomechanical Behavior of Collar and Collarless Stems: Experimental Testing and Finite Element Modelling. J Med Biol Eng 2021. [DOI: 10.1007/s40846-021-00652-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
3
|
Naito Y, Hasegawa M, Tone S, Wakabayashi H, Sudo A. Minimum 10-Year Follow-Up of Cementless Total Hip Arthroplasty With a 32-mm Cobalt-Chromium Head on Highly Cross-Linked Polyethylene and a Tapered, Fiber Metal Proximally Coated Femoral Stem. J Arthroplasty 2021; 36:647-652. [PMID: 32950339 DOI: 10.1016/j.arth.2020.08.055] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Revised: 08/17/2020] [Accepted: 08/26/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND The clinical and radiographic results of cementless total hip arthroplasty using a 32-mm cobalt-chromium head on remelted highly cross-linked polyethylene (HXLPE) and a tapered, fiber metal proximally coated femoral stem were evaluated at a mean follow-up of 12 years. METHODS A total of 57 cementless total hip arthroplasties using remelted HXLPE combined with a 32-mm cobalt-chromium head, and a tapered, fiber metal proximally coated femoral stem were performed from October 2004 to December 2006. Clinical evaluation was performed using the Merle d'Aubigné and Postel scoring system. Standardized anteroposterior and lateral radiographs of the pelvis and femur without weight-bearing were analyzed. Radiographic measurements of two-dimensional femoral head penetration into the polyethylene were performed with a computerized method. The steady-state wear rates were measured based on the radiographs from the first year after surgery to the final follow-up. RESULTS The mean Merle d'Aubigné and Postel score improved significantly from 10.7 points preoperatively to 15.6 postoperatively (P < .001). No osteolysis was found around the implant. Stem fixation in all cases showed stable bone ingrowth. Third-degree stress shielding was found in 46% of all stems. The total head penetration rate was 0.05 mm/y, and the steady-state wear rate was 0.01 mm/y. The Kaplan-Meier survivorship with the end point of revision was 95% (95% confidence interval, 85%-98%) at 12 years. CONCLUSION A 32-mm cobalt-chromium head on remelted HXLPE demonstrated low wear properties, and a tapered, fiber metal proximally coated femoral stem showed good results at long-term follow-up.
Collapse
Affiliation(s)
- Yohei Naito
- Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, Tsu, Mie, Japan
| | - Masahiro Hasegawa
- Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, Tsu, Mie, Japan
| | - Shine Tone
- Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, Tsu, Mie, Japan
| | - Hiroki Wakabayashi
- Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, Tsu, Mie, Japan
| | - Akihiro Sudo
- Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, Tsu, Mie, Japan
| |
Collapse
|
4
|
Hu H, Liu Z, Liu B, Ding X, Liu S, Wu T, Ma W, Han Y. Comparison of Clinical Outcomes, Radiological Outcomes and Bone Remodeling Outcomes Between Proximal Coated Single-Wedge New Stem and Full Coated Dual-Wedge Classic Stem in 1-Stage Bilateral Total Hip Arthroplasty. Med Sci Monit 2020; 26:e921847. [PMID: 32001666 PMCID: PMC7006600 DOI: 10.12659/msm.921847] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Background This retrospective study investigated the clinical outcomes, radiological outcomes, and bone remodeling patterns associated with a Medial/Lateral Taper (M/L Taper) stem and Link Classic Uncemented (LCU) stem in 1-stage bilateral total hip arthroplasty (THA). Material/Methods The results of 52 patients who underwent 1-stage bilateral THA with a M/L Taper stem on one side and an LCU stem on the other between January 2012 and February 2015 were retrospectively compared. Patients were clinically assessed by the Harris hip score (HHS), visual analogue score (VAS) and incidence of complications. Radiological indicators were measured. Periprosthetic bone remodeling was assessed via bone mineral density (BMD) measurements. Results The mean follow-up time was 5.2 years. At each follow-up, there was no difference in the HHS and VAS between the 2 groups. The neck-shaft angle, offset, vertical height of the rotational center and limb lengthening were lower in the M/L Taper group than in the LCU group (P<0.001). The Engh total score was lower in the LCU group (P=0.039). Significantly higher (P<0.001) BMDs were observed in the M/L Taper group in Gruen zones 1, 2, and 6. significantly lower (P<0.001) BMDs were observed in the M/L Taper group in Gruen zones 3 and 5. Conclusions Due to the increased postoperative neck-shaft angle, the full coated dual-wedge classic stem was prone to cause lower limb lengthening. The proximal coated single-wedge new stem patients were more likely to have an insufficient postoperative neck length. The new stem achieved load transfer and proximal fixation, leading to better proximal femoral bone preservation is more in line with human biomechanical characteristics.
Collapse
Affiliation(s)
- Hongpeng Hu
- Department of Osteonecrosis and Hip Surgery, The Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China (mainland)
| | - Zeming Liu
- Department of Osteonecrosis and Hip Surgery, The Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China (mainland)
| | - Bo Liu
- Department of Osteonecrosis and Hip Surgery, The Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China (mainland)
| | - Xuzhuang Ding
- Department of Osteonecrosis and Hip Surgery, The Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China (mainland)
| | - Sikai Liu
- Department of Osteonecrosis and Hip Surgery, The Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China (mainland)
| | - Tao Wu
- Department of Osteonecrosis and Hip Surgery, The Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China (mainland)
| | - Wenhui Ma
- Department of Osteonecrosis and Hip Surgery, The Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China (mainland)
| | - Yongtai Han
- Department of Osteonecrosis and Hip Surgery, The Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China (mainland)
| |
Collapse
|
5
|
Rivière C, Grappiolo G, Engh CA, Vidalain JP, Chen AF, Boehler N, Matta J, Vendittoli PA. Long-term bone remodelling around 'legendary' cementless femoral stems. EFORT Open Rev 2018; 3:45-57. [PMID: 29657845 PMCID: PMC5890130 DOI: 10.1302/2058-5241.3.170024] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
Bone remodelling around a stem is an unavoidable long-term physiological process highly related to implant design. For some predisposed patients, it can lead to periprosthetic bone loss secondary to severe stress-shielding, which is thought to be detrimental by contributing to late loosening, late periprosthetic fracture, and thus rendering revision surgery more complicated.However, these concerns remain theoretical, since late loosening has yet to be documented among bone ingrowth cementless stems demonstrating periprosthetic bone loss associated with stress-shielding.Because none of the stems replicate the physiological load pattern on the proximal femur, each stem design is associated with a specific load pattern leading to specific adaptive periprosthetic bone remodelling. In their daily practice, orthopaedic surgeons need to differentiate physiological long-term bone remodelling patterns from pathological conditions such as loosening, sepsis or osteolysis.To aid in that process, we decided to clarify the behaviour of the five most used femoral stems. In order to provide translational knowledge, we decided to gather the designers' and experts' knowledge and experience related to the design rationale and the long-term bone remodelling of the following femoral stems we deemed 'legendary' and still commonly used: Corail (Depuy); Taperloc (Biomet); AML (Depuy); Alloclassic (Zimmer); and CLS-Spotorno (Zimmer). Cite this article: EFORT Open Rev 2018;3:45-57. DOI: 10.1302/2058-5241.3.170024.
Collapse
Affiliation(s)
- Charles Rivière
- MSK Lab, Imperial College London, UK; South West London Elective Orthopaedic Centre, UK
| | - Guido Grappiolo
- Unit of Hip Diseases and Joint Replacement Surgery, Humanitas Clinical and Research Center, Italy
| | | | | | | | | | | | | |
Collapse
|
6
|
Longitudinal morphological change of acetabular subchondral bone cyst after total hip arthroplasty in developmental dysplasia of the hip. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2018; 28:621-625. [PMID: 29299764 DOI: 10.1007/s00590-017-2115-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2017] [Accepted: 12/20/2017] [Indexed: 10/18/2022]
Abstract
PURPOSE The purpose of this study is to clarify morphological changes of acetabular subchondral bone cyst after total hip arthroplasty for osteoarthritis secondary to developmental dysplasia of the hip. METHODS Two hundred and sixty-one primary cementless total hip arthroplasties of 208 patients, 18 males, 190 females, were retrospectively reviewed. Morphological changes of subchondral bone cyst were evaluated by computed tomography (CT). The mean cross-sectional area of the cyst from CT scans at 3 months postoperatively and after 7-10 years (average 8.4 years) were compared. RESULTS Acetabular subchondral bone cysts were found in 49.0% of all cases in preoperative CT scans. There was no cyst which was newly recognized in CT scan performed after postoperative 7-10 years. All the cross-sectional areas of the cysts evaluated in this study were reduced postoperatively. CONCLUSIONS This study revealed that acetabular subchondral bone cysts do not increase or expand after total hip arthroplasty and indicated that the longitudinal morphological change of acetabular bone cysts in patients of developmental dysplasia of the hip do not influence long-term implant fixation in total hip arthroplasty.
Collapse
|
7
|
Koyano G, Jinno T, Koga D, Yamauchi Y, Muneta T, Okawa A. Comparison of Bone Remodeling Between an Anatomic Short Stem and a Straight Stem in 1-Stage Bilateral Total Hip Arthroplasty. J Arthroplasty 2017; 32:594-600. [PMID: 27554784 DOI: 10.1016/j.arth.2016.07.016] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/29/2015] [Revised: 07/03/2016] [Accepted: 07/08/2016] [Indexed: 02/08/2023] Open
Abstract
BACKGROUND Femurs of dysplastic hips exhibit specific abnormalities, and use of modular or specially designed components is recommended. An anatomic short stem was previously designed specifically for dysplastic hips using 3-dimensional data acquired from dysplastic patients. To investigate effects of stem geometry on bone remodeling, we undertook a prospective, randomized study of patients who had undergone 1-stage bilateral total hip arthroplasty (THA) with the anatomic short stem on one side and a conventional straight stem on the other. METHODS The study included 36 patients who underwent the above THA procedure. We assessed bone mineral density as well as the presence of cancellous condensation or bony atrophy due to stress shielding based on the analysis of Gruen's zones and newly defined equal-interval zones, at an average follow-up period of 9.2 years. RESULTS All stems were bone ingrown stable. Cancellous condensation was observed more proximally, and areas of bone atrophy were narrower on the anatomic short stem side than on the straight stem side. Bone mineral density values reflected results of cancellous condensation and stress shielding and were higher in more proximal zones on the anatomic short stem side than on the straight stem side. CONCLUSION Although radiographic results indicated good midterm outcomes of THA with both stems, the loading pattern differed. The anatomic short stem achieved its design purpose in terms of proximal fixation and load transfer and led to better preservation of the proximal femur.
Collapse
Affiliation(s)
- Gaku Koyano
- Department of Orthopaedic Surgery, Medical Hospital of Tokyo Medical and Dental University, Tokyo, Japan
| | - Tetsuya Jinno
- Department of Orthopaedic Surgery, Medical Hospital of Tokyo Medical and Dental University, Tokyo, Japan
| | - Daisuke Koga
- Department of Orthopaedic Surgery, Medical Hospital of Tokyo Medical and Dental University, Tokyo, Japan
| | - Yuki Yamauchi
- Department of Orthopaedic Surgery, Medical Hospital of Tokyo Medical and Dental University, Tokyo, Japan
| | - Takeshi Muneta
- Department of Orthopaedic Surgery, Medical Hospital of Tokyo Medical and Dental University, Tokyo, Japan
| | - Atsushi Okawa
- Department of Orthopaedic Surgery, Medical Hospital of Tokyo Medical and Dental University, Tokyo, Japan
| |
Collapse
|
8
|
Miyatake K, Jinno T, Koga D, Yamauchi Y, Muneta T, Okawa A. Comparison of Different Materials and Proximal Coatings Used for Femoral Components in One-Stage Bilateral Total Hip Arthroplasty. J Arthroplasty 2015; 30:2237-41. [PMID: 26190568 DOI: 10.1016/j.arth.2015.06.019] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/30/2015] [Revised: 05/15/2015] [Accepted: 06/10/2015] [Indexed: 02/01/2023] Open
Abstract
To evaluate the mid-term effects of different materials and coatings used for femoral components, we prospectively performed 21 one-stage bilateral total hip arthroplasties using 2 anatomical stems which have identical geometries, randomized to side. One stem was made of Ti6Al4V alloy and had a hydroxyapatite coating on grit-blasted surface proximally, and the other was made of TMZF™ alloy and had a proximal coating of hydroxyapatite in addition to an arc-deposited titanium surface coating. Although we found extensions of radiopaque lines to the surface of coatings of seven grit-blasted stems whereas we found none in the case of the arc-deposited titanium stems, all hips showed excellent clinical and radiological outcomes as shown by radiographs and bone mineral density at the final follow-up, average 5.5 years postoperatively.
Collapse
Affiliation(s)
- Kazumasa Miyatake
- Department of Orthopaedic Surgery, Medical Hospital, Tokyo Medical and Dental University, Tokyo, Japan
| | - Tetsuya Jinno
- Department of Orthopaedic Surgery, Medical Hospital, Tokyo Medical and Dental University, Tokyo, Japan
| | - Daisuke Koga
- Department of Orthopaedic Surgery, Medical Hospital, Tokyo Medical and Dental University, Tokyo, Japan
| | - Yuki Yamauchi
- Department of Orthopaedic Surgery, Medical Hospital, Tokyo Medical and Dental University, Tokyo, Japan
| | - Takeshi Muneta
- Department of Orthopaedic Surgery, Medical Hospital, Tokyo Medical and Dental University, Tokyo, Japan
| | - Atsushi Okawa
- Department of Orthopaedic Surgery, Medical Hospital, Tokyo Medical and Dental University, Tokyo, Japan
| |
Collapse
|
9
|
Clarke A, Pulikottil-Jacob R, Grove A, Freeman K, Mistry H, Tsertsvadze A, Connock M, Court R, Kandala NB, Costa M, Suri G, Metcalfe D, Crowther M, Morrow S, Johnson S, Sutcliffe P. Total hip replacement and surface replacement for the treatment of pain and disability resulting from end-stage arthritis of the hip (review of technology appraisal guidance 2 and 44): systematic review and economic evaluation. Health Technol Assess 2015; 19:1-668, vii-viii. [PMID: 25634033 DOI: 10.3310/hta19100] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
BACKGROUND Total hip replacement (THR) involves the replacement of a damaged hip joint with an artificial hip prosthesis. Resurfacing arthroplasty (RS) involves replacement of the joint surface of the femoral head with a metal surface covering. OBJECTIVES To undertake clinical effectiveness and cost-effectiveness analysis of different types of THR and RS for the treatment of pain and disability in people with end-stage arthritis of the hip, in particular to compare the clinical effectiveness and cost-effectiveness of (1) different types of primary THR and RS for people in whom both procedures are suitable and (2) different types of primary THR for people who are not suitable for hip RS. DATA SOURCES Electronic databases including MEDLINE, EMBASE, The Cochrane Library, Current Controlled Trials and UK Clinical Research Network (UKCRN) Portfolio Database were searched in December 2012, with searches limited to publications from 2008 and sample sizes of ≥ 100 participants. Reference lists and websites of manufacturers and professional organisations were also screened. REVIEW METHODS Systematic reviews of the literature were undertaken to appraise the clinical effectiveness and cost-effectiveness of different types of THR and RS for people with end-stage arthritis of the hip. Included randomised controlled trials (RCTs) and systematic reviews were data extracted and risk of bias and methodological quality were independently assessed by two reviewers using the Cochrane Collaboration risk of bias tool and the Assessment of Multiple Systematic Reviews (AMSTAR) tool. A Markov multistate model was developed for the economic evaluation of the technologies. Sensitivity analyses stratified by sex and controlled for age were carried out to assess the robustness of the results. RESULTS A total of 2469 records were screened of which 37 were included, representing 16 RCTs and eight systematic reviews. The mean post-THR Harris Hip Score measured at different follow-up times (from 6 months to 10 years) did not differ between THR groups, including between cross-linked polyethylene and traditional polyethylene cup liners (pooled mean difference 2.29, 95% confidence interval -0.88 to 5.45). Five systematic reviews reported evidence on different types of THR (cemented vs. cementless cup fixation and implant articulation materials) but these reviews were inconclusive. Eleven cost-effectiveness studies were included; four provided relevant cost and utility data for the model. Thirty registry studies were included, with no studies reporting better implant survival for RS than for all types of THR. For all analyses, mean costs for RS were higher than those for THR and mean quality-adjusted life-years (QALYs) were lower. The incremental cost-effectiveness ratio for RS was dominated by THR, that is, THR was cheaper and more effective than RS (for a lifetime horizon in the base-case analysis, the incremental cost of RS was £11,284 and the incremental QALYs were -0.0879). For all age and sex groups RS remained clearly dominated by THR. Cost-effectiveness acceptability curves showed that, for all patients, THR was almost 100% cost-effective at any willingness-to-pay level. There were age and sex differences in the populations with different types of THR and variations in revision rates (from 1.6% to 3.5% at 9 years). For the base-case analysis, for all age and sex groups and a lifetime horizon, mean costs for category E (cemented components with a polyethylene-on-ceramic articulation) were slightly lower and mean QALYs for category E were slightly higher than those for all other THR categories in both deterministic and probabilistic analyses. Hence, category E dominated the other four categories. Sensitivity analysis using an age- and sex-adjusted log-normal model demonstrated that, over a lifetime horizon and at a willingness-to-pay threshold of £20,000 per QALY, categories A and E were equally likely (50%) to be cost-effective. LIMITATIONS A large proportion of the included studies were inconclusive because of poor reporting, missing data, inconsistent results and/or great uncertainty in the treatment effect estimates. This warrants cautious interpretation of the findings. The evidence on complications was scarce, which may be because of the absence or rarity of these events or because of under-reporting. The poor reporting meant that it was not possible to explore contextual factors that might have influenced study results and also reduced the applicability of the findings to routine clinical practice in the UK. The scope of the review was limited to evidence published in English in 2008 or later, which could be interpreted as a weakness; however, systematic reviews would provide summary evidence for studies published before 2008. CONCLUSIONS Compared with THR, revision rates for RS were higher, mean costs for RS were higher and mean QALYs gained were lower; RS was dominated by THR. Similar results were obtained in the deterministic and probabilistic analyses and for all age and sex groups THR was almost 100% cost-effective at any willingness-to-pay level. Revision rates for all types of THR were low. Category A THR (cemented components with a polyethylene-on-metal articulation) was more cost-effective for older age groups. However, across all age-sex groups combined, the mean cost for category E THR (cemented components with a polyethylene-on-ceramic articulation) was slightly lower and the mean QALYs gained were slightly higher. Category E therefore dominated the other four categories. Certain types of THR appeared to confer some benefit, including larger femoral head sizes, use of a cemented cup, use of a cross-linked polyethylene cup liner and a ceramic-on-ceramic as opposed to a metal-on-polyethylene articulation. Further RCTs with long-term follow-up are needed. STUDY REGISTRATION This study is registered as PROSPERO CRD42013003924. FUNDING The National Institute for Health Research Health Technology Assessment programme.
Collapse
Affiliation(s)
- Aileen Clarke
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | | | - Amy Grove
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | - Karoline Freeman
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | - Hema Mistry
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | | | - Martin Connock
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | - Rachel Court
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | | | - Matthew Costa
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | - Gaurav Suri
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | - David Metcalfe
- Warwick Orthopaedics, University Hospitals Coventry and Warwickshire, Coventry, UK
| | - Michael Crowther
- Department of Health Sciences, University of Leicester, Leicester, UK
| | - Sarah Morrow
- Oxford Medical School, University of Oxford, Oxford, UK
| | - Samantha Johnson
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | - Paul Sutcliffe
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| |
Collapse
|
10
|
Yamako G, Chosa E, Zhao X, Totoribe K, Watanabe S, Sakamoto T, Nakane N. Load-transfer analysis after insertion of cementless anatomical femoral stem using pre- and post-operative CT images based patient-specific finite element analysis. Med Eng Phys 2014; 36:694-700. [DOI: 10.1016/j.medengphy.2014.02.018] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2013] [Revised: 01/30/2014] [Accepted: 02/14/2014] [Indexed: 10/25/2022]
|