1
|
Di Maria F, Das S, Abermann E, Hoser C, Fink C. Pulsed lavage is associated with better quality of bone-cement-implant interface in knee arthroplasties (TKA/UKA) compared to syringe lavage in vitro; however, clinical data are missing: A systematic review. J Exp Orthop 2024; 11:e12027. [PMID: 38774578 PMCID: PMC11106550 DOI: 10.1002/jeo2.12027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Revised: 03/08/2024] [Accepted: 03/15/2024] [Indexed: 05/24/2024] Open
Abstract
Purpose The purpose of this systematic review is to analyse the available literature to ascertain the optimal method of bone preparation to improve the quality of bone-cement-implant interface with either pulsed lavage or syringe lavage in both total knee arthroplasty (TKA) and unicompartmental knee arthroplasty (UKA). Methods A comprehensive search was conducted across MEDLINE, Scopus and Embase databases until July 2023. Both inclusion and exclusion criteria were clearly stated and used to identify all the published studies. Subsequent screening throughout the title, abstract and full text was made, followed by complete critical appraisal and data extraction. This sequential process was performed by two reviewers independently and summarised following the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines). A quality assessment of the systematic review was performed according to the Quality Appraisal for Cadaveric Studies scale (QUACS), reaching a quality level ranging from 69% to 85%. Results A total of 10 articles, out of 47, nine biomechanical cadaveric studies and one human clinical study were analysed. A total of 196 UKA tibial components, 74 patellar components, 36 TKA tibial components and 24 UKA femoral components were retrieved, and a high level of heterogeneity resulted overall. The pulsed lavage group showed better cement penetration and higher pull-out force than the syringe lavage group; a higher interface temperature was also found in the pulsed lavage group. No differences were found regarding tension ligament forces between the groups. Conclusion Our systematic review suggests that pulsed lavage is superior to syringe lavage in terms of the quality of bone-cement-implant interface in knee arthroplasties (TKA/UKA). However, translation of these results from cadaveric studies to individual clinical settings may be hazardous; therefore, clinical in vivo prospective studies are highly needed. PROSPERO CRD PROSPERO CRD number CRD42023432399. Level of Evidence Level III.
Collapse
Affiliation(s)
- Fabrizio Di Maria
- Gelenkpunkt‐Sports‐and Joint SurgeryFIFA Medical Centre of ExcellenceInnsbruckAustria
- Research Unit for Orthopaedic Sports Medicine and Injury Prevention (OSMI), Medical Informatics and TechnologyPrivate University for Health SciencesHallAustria
| | - Saubhik Das
- Gelenkpunkt‐Sports‐and Joint SurgeryFIFA Medical Centre of ExcellenceInnsbruckAustria
- Research Unit for Orthopaedic Sports Medicine and Injury Prevention (OSMI), Medical Informatics and TechnologyPrivate University for Health SciencesHallAustria
| | - Elisabeth Abermann
- Gelenkpunkt‐Sports‐and Joint SurgeryFIFA Medical Centre of ExcellenceInnsbruckAustria
- Research Unit for Orthopaedic Sports Medicine and Injury Prevention (OSMI), Medical Informatics and TechnologyPrivate University for Health SciencesHallAustria
| | - Christian Hoser
- Gelenkpunkt‐Sports‐and Joint SurgeryFIFA Medical Centre of ExcellenceInnsbruckAustria
- Research Unit for Orthopaedic Sports Medicine and Injury Prevention (OSMI), Medical Informatics and TechnologyPrivate University for Health SciencesHallAustria
| | - Christian Fink
- Gelenkpunkt‐Sports‐and Joint SurgeryFIFA Medical Centre of ExcellenceInnsbruckAustria
- Research Unit for Orthopaedic Sports Medicine and Injury Prevention (OSMI), Medical Informatics and TechnologyPrivate University for Health SciencesHallAustria
| |
Collapse
|
2
|
Campbell B, Weinberg M, Bischoff J, Scuderi GR. An Evaluation of Anatomic Referencing for Femoral Component Sizing Using Computed Tomography-Based Computer Modeling. J Knee Surg 2024; 37:638-641. [PMID: 38191007 DOI: 10.1055/a-2240-3566] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/10/2024]
Abstract
One of the critical steps in total knee arthroplasty is femoral component positioning and sizing. Historically, there was wider variability between femoral component sizes, necessitating the concepts of anterior referencing (AR) and posterior referencing (PR). With the introduction of smaller increments between sizes, the concept of anatomic referencing has been introduced to replace AR and PR. The intent of this study was to validate the concept of anatomic referencing and show that with 2 mm increments in femoral sizes, the femoral component can be placed flush to the anterior cortex while maintaining posterior condylar offset (PCO). Digital surface models were created using 515 femurs from an established computed tomography database. Virtual bone resections, component sizing and placement were performed assuming neutral mechanical axis and a cartilage thickness of 2 mm. The appropriately sized femoral component, which had 2 mm incremental sizes, was placed flush with the anterior cortex with restoration of the PCO. The anterior-posterior distance from the posterior surface of the component to the medial and lateral surfaces of the posterior condylar cartilage were measured. The medial condyle was the limiting condyle in the majority of cases (73%). The average medial gap after appropriate femoral component matching was 0.6 mm (0.39-1.41 mm) across all sizes. The overall average condylar gap was 1.02 mm. The most common femoral component was a size 7 (57.2 mm) and the average femoral AP width was 55.9 mm. Anatomic referencing with an implant system that has 2-mm increments in femoral component sizing provides an alternative to AR and PR without compromise. Anatomic referencing allows for perfect alignment of the anterior flange of the femoral component to the anterior cortex of the femur while restoring the native PCO to within 1 mm. This avoids having to choose between AR or PR when in between femoral sizes.
Collapse
Affiliation(s)
- Brett Campbell
- Department of Orthopedic Surgery, Penn State Health, St. Joe's Medical Center, Reading, Pennsylvania
| | - Max Weinberg
- Department of Orthopedic Surgery, Zucker School of Medicine at Hofstra/Northwell, Garden City, New York
| | | | - Giles R Scuderi
- Department of Orthopedic Surgery, Zucker School of Medicine at Hofstra/Northwell, Garden City, New York
| |
Collapse
|
3
|
Mika AP, Mulvey HE, Engstrom SM, Polkowski GG, Martin JR, Wilson JM. Can ChatGPT Answer Patient Questions Regarding Total Knee Arthroplasty? J Knee Surg 2024; 37:664-673. [PMID: 38442904 DOI: 10.1055/s-0044-1782233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/07/2024]
Abstract
The internet has introduced many resources frequently accessed by patients prior to orthopaedic visits. Recently, Chat Generative Pre-Trained Transformer, an artificial intelligence-based chat application, has become publicly and freely available. The interface uses deep learning technology to mimic human interaction and provide convincing answers to questions posed by users. With its rapidly expanding usership, it is reasonable to assume that patients will soon use this technology for preoperative education. Therefore, we sought to determine the accuracy of answers to frequently asked questions (FAQs) pertaining to total knee arthroplasty (TKA).Ten FAQs were posed to the chatbot during a single online interaction with no follow-up questions or repetition. All 10 FAQs were analyzed for accuracy using an evidence-based approach. Answers were then rated as "excellent response not requiring clarification," "satisfactory requiring minimal clarification," satisfactory requiring moderate clarification," or "unsatisfactory requiring substantial clarification."Of the 10 answers given by the chatbot, none received an "unsatisfactory" rating with the majority either requiring minimal (5) or moderate (4) clarification. While many answers required nuanced clarification, overall, answers tended to be unbiased and evidence-based, even when presented with controversial subjects.The chatbot does an excellent job of providing basic, evidence-based answers to patient FAQs prior to TKA. These data were presented in a manner that will be easily comprehendible by most patients and may serve as a useful clinical adjunct in the future.
Collapse
Affiliation(s)
- Aleksander P Mika
- Department of Orthopedic Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Hillary E Mulvey
- Department of Orthopedic Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Stephen M Engstrom
- Department of Orthopedic Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Gregory G Polkowski
- Department of Orthopedic Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| | - J Ryan Martin
- Department of Orthopedic Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Jacob M Wilson
- Department of Orthopedic Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| |
Collapse
|
4
|
Anderson PM, Heinz T, Weißenberger M, Winter P, Rudert M, Jakuscheit A. Zirconium as a Promising Synovial Biomarker for Loose Cemented Knee Prosthesis. J Arthroplasty 2024; 39:1714-1718. [PMID: 38244639 DOI: 10.1016/j.arth.2024.01.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Revised: 12/21/2023] [Accepted: 01/09/2024] [Indexed: 01/22/2024] Open
Abstract
BACKGROUND Aseptic loosening is the most common mode of failure after total knee arthroplasty. Despite this, the diagnosis often remains challenging and mainly relies on imaging modalities. Until today, no biomarker exists to aid in diagnosing loosening of the implants. As zirconium (Zr) is often found in bone cement, where it serves as radiopacifier, this study aimed to establish Zr as a synovial biomarker for loosened cemented knee prostheses. METHODS A total of 31 patients scheduled for revision of a cemented knee prostheses were included. In all patients, the initial used cement contained Zr. After arthrotomy, specimens of synovial fluid were taken and levels of Zr were measured by inductively coupled plasma mass spectrometry. Depending on the necessary amount of force for explantation, the implants were graded "loose" or "well-fixed". Preoperative radiographs were evaluated by 2 independent physicians. RESULTS The concentration of Zr in the synovial fluid differed significantly (P < .001) between the "loose" (mean 170.9 μg/L, range 0 to 1941 μg/L) and the "well-fixed" (mean 0.6 μg/L, range 0 to 6 μg/L) implants. The receiver operating characteristic analysis revealed 0.25 μg/l as an optimal cutoff value leading to a sensitivity of 0.84, a specificity of 0.92, a positive predictive value of 0.94, and a negative predictive value of 0.79. There was no significant difference in the diagnostic performance compared to radiographs (P = .66). CONCLUSIONS Zirconium proved to be a reliable novel synovial biomarker for diagnosing aseptic loosening of knee prothesis fixed with cement containing Zr. This biomarker should not be interpreted in isolation, but in combination with existing diagnostic tools.
Collapse
Affiliation(s)
- Philip M Anderson
- Department of Orthopedics, Orthopädische Klinik König-Ludwig-Haus, University of Wuerzburg, Würzburg, Germany
| | - Tizian Heinz
- Department of Orthopedics, Orthopädische Klinik König-Ludwig-Haus, University of Wuerzburg, Würzburg, Germany
| | - Manuel Weißenberger
- Department of Orthopedics, Orthopädische Klinik König-Ludwig-Haus, University of Wuerzburg, Würzburg, Germany
| | - Philipp Winter
- Department of Orthopaedic Surgery, University of Saarland, Homburg, Germany
| | - Maximilian Rudert
- Department of Orthopedics, Orthopädische Klinik König-Ludwig-Haus, University of Wuerzburg, Würzburg, Germany
| | - Axel Jakuscheit
- Department of Orthopedics, Orthopädische Klinik König-Ludwig-Haus, University of Wuerzburg, Würzburg, Germany
| |
Collapse
|
5
|
Guan S, Dumas R, Pandy MG. Tibiofemoral Slip Velocity in Total Knee Arthroplasty is Design-Invariant but Activity-Dependent. Ann Biomed Eng 2024; 52:1779-1794. [PMID: 38530534 DOI: 10.1007/s10439-024-03490-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Accepted: 03/11/2024] [Indexed: 03/28/2024]
Abstract
Tibiofemoral slip velocity is a key contributor to total knee arthroplasty (TKA) component wear, yet few studies have evaluated this quantity in vivo. The aim of the present study was to measure and compare tibiofemoral slip velocities in 3 TKA designs for a range of daily activities. Mobile biplane X-ray imaging was used to measure 6-degree-of-freedom tibiofemoral kinematics and the locations of articular contact in 75 patients implanted with a posterior-stabilized, cruciate-retaining, or medial-stabilized design while each patient performed level walking, step up, step down, sit-to-stand, and stand-to-sit. Using these data, tibiofemoral slip velocity was calculated for the duration of each activity for each TKA design. The pattern of tibiofemoral slip velocity was similar for all 3 TKA designs within each activity but markedly different across the 5 activities tested, with the magnitude of peak slip velocity being significantly higher in level walking (range: 158-211 mm/s) than in all other activities (range: 43-75 mm/s). The pattern of tibiofemoral slip velocity in both the medial and lateral compartments closely resembled the pattern of tibiofemoral (knee) flexion angular velocity, with a strong linear relationship observed between slip velocity and flexion angular velocity (r = 0.81-0.97). Tibiofemoral slip velocity was invariant to TKA design but was significantly affected by activity type. Our measurements of slip velocity and articular contact locations for a wide range of daily activities may be used as inputs in joint simulator testing protocols and computational models developed to estimate TKA component wear.
Collapse
Affiliation(s)
- Shanyuanye Guan
- Department of Mechanical Engineering, University of Melbourne, Parkville, Victoria, 3010, Australia
| | - Raphael Dumas
- University of Lyon, University Gustave Eiffel, University Claude Bernard Lyon 1, LBMC UMR T_9406, F-69622, Lyon, France
| | - Marcus G Pandy
- Department of Mechanical Engineering, University of Melbourne, Parkville, Victoria, 3010, Australia.
| |
Collapse
|
6
|
Dubin J, Hameed D, Moore MC, Bains SS, Patel S, Nace J, Mont MA, Delanois RE. Methodological Assessment of the 100 Most-Cited Articles in Total Knee Arthroplasty in the Last Decade Compared to the All-Time List. J Arthroplasty 2024; 39:1434-1443.e5. [PMID: 38135168 DOI: 10.1016/j.arth.2023.12.030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Revised: 12/04/2023] [Accepted: 12/15/2023] [Indexed: 12/24/2023] Open
Abstract
BACKGROUND Recent advances in total knee arthroplasty (TKA) have been driven by a growing focus on evidence-based medicine. This transition is reflected in the critical appraisal of both, the quality of work and the potential impact on the orthopedic community. The purpose of our study was to (1) identify the top 100 most-cited articles in TKA in the last decade and from all-time, and (2) compare methodological rigor of the most-cited articles in TKA in the last decade to articles all-time by level of evidence. METHODS The top 100 cited articles were recorded for manuscripts from the last decade, January 1, 2012 to December 31, 2022, and manuscripts from all-time for TKA. We collected authors, year of publication, journal of the article, country of origin of authors, article type (basic science article, clinical research article), level of evidence, methodological index for non-randomized studies score, physiotherapy evidence database scale, and citation density (total citations/years published). RESULTS The largest number of studies for all-time TKA (53.0%) and decade TKA (42.0%) were Level III. The average methodological index for non-randomized studies score for comparative studies was 18.7 for all-time TKA and 20.7 for decade TKA (P < .001). The average physiotherapy evidence database score was 6.1 for all-time TKA and 8.1 for decade TKA (P > .05). The highest citation density for all-time TKA was 111 and for past decade was 63. The number of level II studies in TKA increased from 19.0% from all time to 38.0% from the last decade (P < .05). CONCLUSIONS Our findings of improved methodologies over time reflect positive steps toward evidence-based practice in TKA. A continued focus on producing methodologically sound studies may guide evidence-based clinical decision-making.
Collapse
Affiliation(s)
- Jeremy Dubin
- Rubin Institute for Advanced Orthopedics, LifeBridge Health, Sinai Hospital of Baltimore, Baltimore, Maryland
| | - Daniel Hameed
- Rubin Institute for Advanced Orthopedics, LifeBridge Health, Sinai Hospital of Baltimore, Baltimore, Maryland
| | - Mallory C Moore
- Rubin Institute for Advanced Orthopedics, LifeBridge Health, Sinai Hospital of Baltimore, Baltimore, Maryland
| | - Sandeep S Bains
- Rubin Institute for Advanced Orthopedics, LifeBridge Health, Sinai Hospital of Baltimore, Baltimore, Maryland
| | - Saarang Patel
- Rubin Institute for Advanced Orthopedics, LifeBridge Health, Sinai Hospital of Baltimore, Baltimore, Maryland
| | - James Nace
- Rubin Institute for Advanced Orthopedics, LifeBridge Health, Sinai Hospital of Baltimore, Baltimore, Maryland
| | - Michael A Mont
- Rubin Institute for Advanced Orthopedics, LifeBridge Health, Sinai Hospital of Baltimore, Baltimore, Maryland
| | - Ronald E Delanois
- Rubin Institute for Advanced Orthopedics, LifeBridge Health, Sinai Hospital of Baltimore, Baltimore, Maryland
| |
Collapse
|
7
|
van Duren BH, Lee K, Firth AM, Imuetinyan E, Ilo K, Berber R, Matar HE, Bloch BV. Postoperative Continuous Passive Motion Does Not Improve the Range of Movement Achieved After Manipulation Under Anesthetic for Stiffness in Total Knee Replacement. Arthroplast Today 2024; 27:101397. [PMID: 38882466 PMCID: PMC11180303 DOI: 10.1016/j.artd.2024.101397] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Revised: 03/25/2024] [Accepted: 04/02/2024] [Indexed: 06/18/2024] Open
Abstract
Background Stiffness is a common complication following total knee arthroplasty. Manipulation under anesthesia (MUA) is an intervention that can potentially improve range of motion (ROM). Continuous passive motion (CPM) therapy has been utilized to enhance post-MUA ROM, but its effectiveness remains debated. This study assesses whether CPM therapy after MUA results in superior ROM outcomes compared to MUA alone. Methods A retrospective analysis included patients undergoing MUA for stiff primary total knee arthroplasty between 2017 and 2022. Demographics and ROM data were collected. Patients were in 2 groups: those who received inpatient CPM post-MUA and those who received day-case MUA alone. Complications and further interventions were noted. Results Of 126 patients, 39 underwent MUA only (day-case group), and 87 received CPM and MUA (inpatient group). Mean preoperative ROM was 69.4° (standard deviation [SD]:18.0°) and 73.9° (SD: 18.1°) for inpatient and day-case groups, respectively. Mean post-MUA ROM improved by 39.4° (SD: 17.7°) and 25.5° (SD: 11.1°) inpatient groups and day-case, respectively. The mean percentage of ROM gained at MUA maintained at final follow-up was 63.7% (40.8%) and 67.0% (47.5%) inpatient and day-case groups, respectively. Conclusions This study found no advantage in the routine use of CPM post-MUA for stiff total knee replacement patients, suggesting it may not provide sustained ROM improvements compared to MUA alone. Cost-effectiveness and patient selection merit further investigation.
Collapse
Affiliation(s)
- Bernard H van Duren
- Nottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, UK
- Leeds Institute of Rheumatic and Musculoskeletal Medicine, University of Leeds, Leeds, UK
| | - Katie Lee
- Nottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, UK
| | - Amy M Firth
- Nottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, UK
| | - Efosa Imuetinyan
- Nottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, UK
| | - Kevin Ilo
- Nottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, UK
| | - Reshid Berber
- Nottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, UK
| | - Hosam E Matar
- Nottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, UK
| | - Benjamin V Bloch
- Nottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, UK
| |
Collapse
|
8
|
Panwar KS, Huish EG, Law JL, Deans JT, Staples JR, Eisemon EO, Lum ZC. Revision Total Joint Arthroplasty Places a Disproportionate Burden on Surgeons: A Comparison Using the National Aeronautics and Space Administration Task Load Index (NASA TLX). J Arthroplasty 2024; 39:1550-1556. [PMID: 38218555 DOI: 10.1016/j.arth.2024.01.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/17/2023] [Revised: 12/19/2023] [Accepted: 01/02/2024] [Indexed: 01/15/2024] Open
Abstract
BACKGROUND Perceived surgeon workload of performing primary and revision total hip arthroplasty (THA) and total knee arthroplasty (TKA) is challenging to quantify. The National Aeronautics and Space Administration Task Load Index (NASA TLX) survey was developed to quantify experiences following aviation and has been applied to healthcare fields. Our purposes were to 1) quantify the workload endured by surgeons who are performing primary and revision TKA and THA and 2) compare these values to their Center for Medicare & Medicaid Services (CMS) reimbursement. METHODS A prospective cohort of 5 fellowship-trained adult reconstruction surgeons completed NASA TLX surveys following primary and revision TKA/THA cases. A total of 122 surveys consisting of 70 TKA (48 primaries and 22 revisions) and 55 THA surveys (38 primaries and 17 revisions) were completed. Patient demographics and surgical variables were recorded. Final NASA TLX workloads were compared to 2021 CMS work relative value units. RESULTS Compared to primary TKA, revision TKA had 176% increased intraoperative workload (P < .001), 233% increased mental burden (P < .001), and 150% increased physical burden (P < .001). Compared to primary THA, revision THA had 106% increased intraoperative workload (P < .001), 96% increased mental burden (P < .001), and 91% increased physical burden (P < .001). Operative time was higher in revision versus primary TKA (118 versus 84.5 minutes, P = .05) and THA (150 versus 115 minutes, P = .001). Based upon 2021 CMS data, revision TKA and THA would need to be compensated by an additional 36% and 12.3%, respectively, to parallel intraoperative efforts. CONCLUSIONS Revision hip and knee arthroplasty places a major mental and physical workload upon surgeons and is disproportionately compensated by CMS.
Collapse
Affiliation(s)
- Kunal S Panwar
- Department of Orthopedic Surgery, San Joaquin General Hospital, Stockton, California
| | - Eric G Huish
- Department of Orthopedic Surgery, San Joaquin General Hospital, Stockton, California
| | - Jesua L Law
- Department of Orthopedic Surgery, Doctors Medical Center, Modesto, California
| | - Justin T Deans
- Department of Orthopedic Surgery, Doctors Medical Center, Modesto, California
| | - Jonathon R Staples
- Department of Orthopedic Surgery, Memorial Medical Center, Modesto, California
| | - Eric O Eisemon
- Department of Orthopedic Surgery, Kaiser Permanente, Oakland, California
| | - Zachary C Lum
- Department of Orthopaedic Surgery, UC Davis Medical Center, University of California, Sacramento, California
| |
Collapse
|
9
|
Yapar A, Köse Ö, Özdöl Ç, Luo TD, Budin M, Rosa GF, Gehrke T, Citak M. Increased Involvement of Staphylococcus epidermidis in the Rise of Polymicrobial Periprosthetic Joint Infections. J Arthroplasty 2024:S0883-5403(24)00547-3. [PMID: 38823523 DOI: 10.1016/j.arth.2024.05.075] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/09/2024] [Revised: 05/26/2024] [Accepted: 05/27/2024] [Indexed: 06/03/2024] Open
Abstract
BACKGROUND In this study, we aimed to analyze the temporal distribution of polymicrobial periprosthetic joint infections (PJIs), while also evaluating the patient risk factors associated with these infections following total joint arthroplasty at our institution across 2 distinct periods. METHOD This retrospective cross-sectional study evaluated 259 patients who had knee or hip PJI from 2001 to 2006 and 2018 to 2022. A PJI was diagnosed using the 2018 International Consensus Meeting criteria. We utilized the Polymicrobial Pathogens' Co-occurrence Network Analysis, a novel approach that leverages network theory to map and quantify the complex interplay of organisms in PJIs. RESULTS Of the 259 patients who had polymicrobial PJI, 58.7% were men, with mean age 67 years (range, 24 to 90). Of the 579 identified pathogens, Staphylococcus epidermidis was the most common (22.1%), followed by Staphylococcus aureus (9.0%) and Cutibacterium acnes (7.8%). The co-occurrence analysis indicated that Staphylococcus epidermidis frequently coexisted with Cutibacterium acnes (26 cultures) and Staphylococcus capitis (22 cultures). A notable increase in body mass index from 27.7 ± 4.4 in 2001 to 2006 to 29.7 ± 6.2 in 2018 to 2022 was observed (P = .001). Moreover, infections from Staphylococcus epidermidis, Cutibacterium acnes, and Staphylococcus capitis saw a significant uptick (P < .001). CONCLUSIONS The study shows that from 2001 to 2022, there was a significant change in the pathogens responsible for polymicrobial PJIs, particularly an increase in Staphylococcus epidermidis, Cutibacterium acnes, and Staphylococcus capitis. Alongside these microbial changes, there was a rise in body mass index and shifts in comorbid conditions, such as more renal disease and fewer cases of congestive heart failure. These changes highlight the dynamic interplay between host and microbial factors in the pathogenesis of polymicrobial PJIs, necessitating adaptive strategies in both surgical and postoperative care to mitigate the rising tide of these complex infections.
Collapse
Affiliation(s)
- Aliekber Yapar
- Department of Orthopaedic Surgery, ENDO-Klinik Hamburg, Hamburg, Germany; Department of Orthopedics and Traumatology, Antalya Training and Research Hospital, Antalya, Turkey
| | - Özkan Köse
- Department of Orthopedics and Traumatology, Antalya Training and Research Hospital, Antalya, Turkey
| | - Çağla Özdöl
- Department of Orthopaedic Surgery, ENDO-Klinik Hamburg, Hamburg, Germany
| | - T David Luo
- Department of Orthopaedic Surgery, ENDO-Klinik Hamburg, Hamburg, Germany; Division of Adult Reconstruction, Orthopaedics Northeast, Fort Wayne, Indiana
| | - Maximilian Budin
- Department of Orthopaedic Surgery, ENDO-Klinik Hamburg, Hamburg, Germany
| | - Gianmaria F Rosa
- Department of Orthopaedic Surgery, ENDO-Klinik Hamburg, Hamburg, Germany
| | - Thorsten Gehrke
- Department of Orthopaedic Surgery, ENDO-Klinik Hamburg, Hamburg, Germany
| | - Mustafa Citak
- Department of Orthopaedic Surgery, ENDO-Klinik Hamburg, Hamburg, Germany
| |
Collapse
|
10
|
Rudolph F, Brand AG, Osterhoff G, Kleber C, Roth A, Fakler JKM. Retrograde intramedullary nail fixation with oblique fixed angle screws versus locking plates in periprosthetic supracondylar fractures after total knee arthroplasty. Eur J Trauma Emerg Surg 2024:10.1007/s00068-024-02530-x. [PMID: 38806687 DOI: 10.1007/s00068-024-02530-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2024] [Accepted: 04/19/2024] [Indexed: 05/30/2024]
Abstract
PURPOSE Common surgical procedures in the treatment of periprosthetic distal femur fractures (PPFF) include osteosynthesis with fixed angle locking plates (LP) and retrograde intramedullary nails (RIN). This study aimed to compare LPs to RINs with oblique fixed angle screws in terms of complications, radiographic results and functional outcome. METHODS 63 PPFF in 59 patients who underwent treatment in between 2009 and 2020 were included and retrospectively reviewed. The anatomic lateral and posterior distal femoral angle (aLDFA and aPDFA) were measured on post-surgery radiographs. The Fracture Mobility Score (FMS) pre- and post-surgery, information about perceived instability in the operated leg and the level of pain were obtained via a questionnaire and previous follow-up (FU) examinations in 30 patients (32 fractures). RESULTS The collective (median age: 78 years) included 22 fractures treated with a RIN and 41 fractures fixed with a LP. There was no difference in the occurrence of complications (median FU: 21.5 months) however the rate of implant failures requiring an implant replacement was higher in fractures treated with a LP (p = 0.043). The aPDFA was greater in fractures treated with a RIN (p = 0.04). The functional outcome was comparable between both groups (median FU: 24.5 months) with a lower outcome in the post-surgery FMS (p = < 0.001). CONCLUSION Fractures treated with RIN resulted in an increased recurvation of the femur however the rate of complications and the functional outcome were comparable between the groups. The need for implant replacements following complications was higher in the LP group.
Collapse
Affiliation(s)
- Franziska Rudolph
- Department of Orthopedic, Trauma and Plastic Surgery, University Hospital of Leipzig, Liebigstr. 20, 04103, Leipzig, Germany.
- Department of Traumatology, University Hospital of Zurich, Rämistrasse 100, 8091, Zurich, Switzerland.
| | - Alexander G Brand
- Department of Orthopedic, Trauma and Plastic Surgery, University Hospital of Leipzig, Liebigstr. 20, 04103, Leipzig, Germany
| | - Georg Osterhoff
- Department of Orthopedic, Trauma and Plastic Surgery, University Hospital of Leipzig, Liebigstr. 20, 04103, Leipzig, Germany
| | - Christian Kleber
- Department of Orthopedic, Trauma and Plastic Surgery, University Hospital of Leipzig, Liebigstr. 20, 04103, Leipzig, Germany
| | - Andreas Roth
- Department of Orthopedic, Trauma and Plastic Surgery, University Hospital of Leipzig, Liebigstr. 20, 04103, Leipzig, Germany
| | - Johannes K M Fakler
- Department of Orthopedic, Trauma and Plastic Surgery, University Hospital of Leipzig, Liebigstr. 20, 04103, Leipzig, Germany
- Department of Trauma-, Hand-, Reconstructive- and Spine Surgery, Hospital of Passau, Innstraße 76, 94032, Passau, Germany
| |
Collapse
|
11
|
Hauer G, Rasic L, Klim S, Leitner L, Leithner A, Sadoghi P. Septic complications are on the rise and aseptic loosening has decreased in total joint arthroplasty: an updated complication based analysis using worldwide arthroplasty registers. Arch Orthop Trauma Surg 2024:10.1007/s00402-024-05379-2. [PMID: 38795186 DOI: 10.1007/s00402-024-05379-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Accepted: 05/07/2024] [Indexed: 05/27/2024]
Abstract
INTRODUCTION A decade ago, a comprehensive study was conducted to investigate the reasons for revision surgeries and their respective frequencies in cases of total hip arthroplasty (THA) and total knee arthroplasty (TKA) based on a complication-based analysis of joint replacement registries. The aim of the present study was to determine whether the causes and risks of their occurrence have changed over the last ten years and to present an updated analysis. MATERIALS AND METHODS A systematic review of national arthroplasty registries from seven countries examined the causes and rates of revisions of THA and TKA. The study focused on a descriptive analysis that provided an updated overview without statistical significance values. RESULTS The most common causes for revisions of THA were aseptic loosening (35.1%), deep infection (18.2%), dislocation/instability (15.9%), and periprosthetic fractures (11.4%). The most common causes for revisions of TKA were deep infection (21.6%), aseptic loosening (18.3%), instability (14.1%), and pain (10.9%). CONCLUSION The findings of this study revealed significant shifts in the underlying causes of revision surgeries in the last decade. Notably, septic complications emerged as the predominant reason for revision of primary TKA, while they also gained prominence as a cause of failure of THA. Although aseptic loosening remains the primary cause for re-operation of THA, the relative risk has decreased for both THA and TKA.
Collapse
Affiliation(s)
- Georg Hauer
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, Graz, 8036, Austria.
| | - Laura Rasic
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, Graz, 8036, Austria
| | - Sebastian Klim
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, Graz, 8036, Austria
| | - Lukas Leitner
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, Graz, 8036, Austria
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), LMU University Hospital, Munich, Germany
| | - Andreas Leithner
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, Graz, 8036, Austria
| | - Patrick Sadoghi
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, Graz, 8036, Austria
| |
Collapse
|
12
|
Kohring A, Parikh N, Hobbs J, Lowitz S, Gold P, Krueger CA. The Effect of Cemented Implants Placed During Initial TKA on Surgical Time and Expenses in Revision TKA. J Am Acad Orthop Surg 2024:00124635-990000000-00991. [PMID: 38759227 DOI: 10.5435/jaaos-d-23-01184] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Accepted: 04/18/2024] [Indexed: 05/19/2024] Open
Abstract
INTRODUCTION Revision total knee arthroplasty (rTKA) is a complex procedure that often requires the removal of previous implants. There is little information evaluating the difference between removing cemented or noncemented knee prostheses in revision surgeries. The purpose of this study was to determine whether removing cemented or noncemented implants would affect surgical time and expenses incurred during revision procedures. METHODS This retrospective cohort study used a single-institution database to identify 300 patients who underwent femoral and tibial implant rTKA from 2016 to 2022 because of mechanical complications (infection cases excluded). Radiographs and surgical reports were used to confirm whether the fixation technique was cemented (N = 243) or noncemented (N = 57). The primary outcomes were surgical time and surgery costs. Secondary outcomes included readmission rates, revision implants used, stem usage, and insurance type. RESULTS The average surgical time was 121 minutes for noncemented and 128 minutes for cemented procedures (P = 0.118). The 90-day readmission rates for each group were similar at 7.00% for the cemented cohort and 8.77% for the noncemented cohort (P = 0.643). For patients with Medicare Advantage, the respective surgery costs were $1,966 for noncemented and $1,968 for cemented TKA (P = 0.988). For patients with commercial insurance, the respective surgery costs were $4,854 for noncemented and $5,660 for cemented TKA (P = 0.330). CONCLUSION Primary knee fixation type, cemented or noncemented, did not appear to influence the surgical duration or surgical costs of both-implant revision knee surgery indicated for mechanical complications.
Collapse
Affiliation(s)
- Adam Kohring
- From the Jefferson Health New Jersey (Kohring), Rothman Orthopaedic Institute at Thomas Jefferson University, Philadelphia, PA (Parikh, Hobbs, and Krueger), Midwestern University, Downers Grove, IL (Lowitz), and Panorama Orthopedic & Spine Center, Golden, CO (Gold)
| | | | | | | | | | | |
Collapse
|
13
|
Kleeman-Forsthuber LT, Owens JM, Johnson RM, Clary CW, Elkins JM, Dennis DA. Clinical and Computational Evaluation of an Anatomic Patellar Component. J Arthroplasty 2024:S0883-5403(24)00438-8. [PMID: 38735546 DOI: 10.1016/j.arth.2024.05.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 05/01/2024] [Accepted: 05/02/2024] [Indexed: 05/14/2024] Open
Abstract
BACKGROUND Anatomic patellar components for total knee arthroplasty (TKA) have demonstrated favorable in vivo kinematics. A novel failure mechanism in TKA patients with an anatomic patellar component was observed prompting an investigation to identify patient- and implant-related factors associated with suboptimal performance. METHODS A retrospective evaluation was performed comparing 100 TKA patients with an anatomic patellar component to 100 gender-, age-, and body mass index-matched patients with a medialized dome component. All surgeries were performed with the same posterior-stabilized TKA system with minimum of 1-year follow-up. Several radiographic parameters were assessed. A separate computational evaluation was performed using finite-element analysis, comparing bone strain energy density through the patella bone remnant. RESULTS Patients with an anatomic patellar component had significantly higher rates of anterior knee pain (18 versus 2%, P < .001), chronic effusions (18 versus 2%, P < .001), and superior patellar pole fragmentation (36 versus 13%, P < .001) compared to those with a dome component. Radiographically, the anatomic group demonstrated more lateral patellar subluxation (2.3 versus 1.1 mm, P < .001) and lateral tilt (5.4 versus 4.0 mm, P = .013). Furthermore, there were more revisions in the anatomic group (7 versus 3, P = .331). On computational evaluation, all simulations demonstrated increased bone strain energy density at the superior patellar pole with the anatomic patella. Resection thickness <13 mm resulted in over 2-fold higher strain energy density, and negative resection angle of 7° resulted in 6-fold higher superior pole strain energy. CONCLUSIONS Patients with an anatomic patellar component showed higher rates of anterior knee pain, chronic effusion, and superior pole fragmentation compared to patients with a dome patella, with higher superior patellar pole strain energy confirmed on computational evaluation. Avoiding higher resection angles and excessive patellar resection may improve the performance and survivorship of the anatomic patella.
Collapse
Affiliation(s)
| | - Jessell M Owens
- Swift Institute, Sparks, Nevada; Colorado Joint Replacement, Denver, Colorado
| | | | - Chadd W Clary
- Center for Orthopaedic Biomechanics, University of Denver, Denver, Colorado
| | - Jacob M Elkins
- Department of Orthopaedics, University of Iowa, Iowa City, Iowa
| | - Douglas A Dennis
- Colorado Joint Replacement, Denver, Colorado; Department of Bioengineering, University of Tennessee, Knoxville, Tennessee; Denver University, Denver, Colorado; Department of Orthopaedics, University of Colorado School of Medicine, Denver, Colorado
| |
Collapse
|
14
|
Luo TD, Sogbein OA, MacDonald BM, Masse JA, Willing RT, Lanting BA. Central cone design demonstrates greater micromotion compared to keel design in cementless tibial baseplates: A biomechanical analysis. Knee Surg Sports Traumatol Arthrosc 2024. [PMID: 38713877 DOI: 10.1002/ksa.12224] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/25/2024] [Revised: 04/19/2024] [Accepted: 04/20/2024] [Indexed: 05/09/2024]
Abstract
PURPOSE The purpose of this study was to compare micromotion of two new cementless tibial baseplates to a cementless design with well-published clinical success. METHODS Three cementless tibial baseplate designs (fixed-bearing [FB] with keel and cruciform pegs, rotating-platform with porous central cone and pegs, FB with cruciform keel and scalloped pegs) were evaluated on sawbone models. Loading was applied to the baseplate at a rate of 1 Hz for 10,000 cycles, which represents 6-8 weeks of stair descent. This time frame also represents the approximate time length for the induction of biologic fixation of cementless implants. Compressive and shear micromotion at the sawbone-implant interface were measured. RESULTS At the end of the loading protocol, the central cone rotating-platform design exhibited greater micromotion at the anterior (p < 0.001), posterior (p < 0.001) and medial locations (p = 0.049) compared to the other two implants. The central cone design also exhibited greater translational micromotion in the sagittal plane at the medial (p = 0.001) and lateral locations (p = 0.034) and in the coronal plane anteriorly (p = 0.007). CONCLUSION The cementless central cone rotating-platform baseplate demonstrated greater vertical and translational micromotion compared to the two FB baseplates with a keel underloading. This may indicate lower initial mechanical stability in implants without a keel, which possibly affects osseointegration. The implication of this is yet unknown and requires further long-term clinical follow-up to correlate these laboratory findings. LEVEL OF EVIDENCE V (biomechanical study).
Collapse
Affiliation(s)
- Tianya David Luo
- Department of Orthopaedic Surgery, London Health Sciences Centre, University Hospital, London, Ontario, Canada
- Orthopaedics Northeast, Fort Wayne, Indiana, USA
| | - Olawale A Sogbein
- Department of Orthopaedic Surgery, London Health Sciences Centre, University Hospital, London, Ontario, Canada
| | - Brett M MacDonald
- Department of Mechanical & Materials Engineering, University of Western Ontario, London, Ontario, Canada
| | - Jarrett A Masse
- Department of Mechanical & Materials Engineering, University of Western Ontario, London, Ontario, Canada
| | - Ryan T Willing
- Department of Mechanical & Materials Engineering, University of Western Ontario, London, Ontario, Canada
| | - Brent A Lanting
- Department of Orthopaedic Surgery, London Health Sciences Centre, University Hospital, London, Ontario, Canada
| |
Collapse
|
15
|
Hiranaka T. Current concept: personalized alignment total knee arthroplasty as a contrast to classical mechanical alignment total knee arthroplasty. ARTHROPLASTY 2024; 6:23. [PMID: 38705976 PMCID: PMC11071279 DOI: 10.1186/s42836-024-00246-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2023] [Accepted: 02/26/2024] [Indexed: 05/07/2024] Open
Abstract
Mechanical alignment (MA) total knee arthroplasty (TKA), with neutral leg alignment, mechanical component alignment, and parallel gaps, has achieved good long-term survival. Patient satisfaction, however, is not always perfect. In contrast to the MA, which aims for an ideal goal for all patients, an alternative has been proposed: kinematic alignment (KA)-TKA. In KA, the articular surface is replicated using components aligning with the three kinematic axes. KA-TKA has been gaining popularity, and in addition to the true or calipered KA, various derivatives, such as restricted KA, soft-tissue respecting KA, and functional alignments, have been introduced. Moreover, the functional approach encompasses several sub-approaches. This somewhat complicated scenario has led to some confusion. Therefore, the terminology needs to be re-organized. The term "personalized alignment (PA)" has been used in contrast to the MA approach, including all approaches other than MA. The term "PA-TKA" should be used comprehensively instead of KA and it represents the recent trends in distinct and unique consideration of each individual case. In addition to a comparison between MA and KA, we suggest that evaluation should be conducted to decide which approach is the best for an individual patient within the "personalized alignment" concept.
Collapse
Affiliation(s)
- Takafumi Hiranaka
- Department of Orthopaedic Surgery and Joint Surgery Centre, Takatsuki General Hospital, Osaka, 569-1192, Japan.
| |
Collapse
|
16
|
Costales TG, Dalury DF. Four-Year Outcomes of Cementless Versus Cemented Fixation of a Newly Introduced Total Knee Arthroplasty Design. Orthopedics 2024; 47:161-166. [PMID: 38285554 DOI: 10.3928/01477447-20240122-02] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2024]
Abstract
BACKGROUND Aseptic loosening continues to be a major cause of failure of total knee arthroplasty (TKA). Although cemented fixation remains the gold standard, there is renewed interest in cementless fixation as a means of decreasing this risk via biologic fixation. The purpose of this study was to evaluate the clinical outcomes of cemented and cementless versions of a newly introduced TKA design at an average of 4 years postoperatively. MATERIALS AND METHODS This was a retrospective case-control study of 100 primary TKAs comparing cementless vs cemented TKAs using the same cruciate-retaining implant design (ATTUNE Knee System; DePuy Synthes). Fifty patients undergoing cementless TKA with a mean age of 60.8 years (range, 48-71 years) and body mass index (BMI) of 31.6 kg/m2 (range, 23.7-41.9 kg/m2) were matched to 50 patients undergoing primary cemented TKA with a mean age of 62.7 years (range, 51-73 years) and BMI of 30.1 kg/m2 (range, 24.6-43.9 kg/m2). The mean follow-up was 4.2 years (range, 4.0-4.4 years) in the cementless group and 7.6 years (range, 7.5-7.7 years) in the cemented group. Complications, clinical outcomes using the Knee Society Score (KSS), and radiographic analyses were evaluated at final follow-up. Student's t tests were used for statistical analyses. RESULTS There was no statistical difference in age, BMI, and preoperative KSS between the two groups (P=.12, P=.15, and P=.55, respectively). There were no complications or reoperations in either cohort. There were no statistical differences in range of motion and total KSS at final follow-up between the two groups. Final total KSS had a mean of 91.1 for the cementless group and 93.7 for the cemented group. There was no radiographic evidence of component subsidence or loosening in either cohort. CONCLUSION When compared with its cemented counterpart, the newly introduced cementless TKA design had similar excellent clinical improvements and radiologic results at an average of 4 years of follow-up. [Orthopedics. 2024;47(3):161-166.].
Collapse
|
17
|
Lin J, Burge A, Li Q, Geannette C, Miller TT. Ultrasound assessment of synovitis in total knee replacements: concordance with MR imaging and joint aspiration. Skeletal Radiol 2024; 53:863-869. [PMID: 37930380 DOI: 10.1007/s00256-023-04485-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/29/2023] [Revised: 10/14/2023] [Accepted: 10/15/2023] [Indexed: 11/07/2023]
Abstract
OBJECTIVE To determine if diagnostic ultrasound can reliably distinguish between synovial patterns of prosthetic joint infection and polymeric wear in total knee replacements. METHODS AND METHODS This retrospective study was approved by our hospital IRB. Using the radiology report database, MR examinations performed within a week of diagnostic ultrasound and/or ultrasound-guided aspiration were identified. This yielded (1) 24 cases with MR and ultrasound comparisons; (2) 44 cases with MR, ultrasound, and aspiration comparisons; and (3) 92 cases with ultrasound and aspiration comparisons. The MR studies were reviewed by a musculoskeletal radiologist. The ultrasound studies were each reviewed by 2 other musculoskeletal radiologists. Each study was graded for synovial pattern indicating infection, polymeric wear, or normal/nonspecific. Agreement between the MR grader and the ultrasound graders as well as ultrasound inter-rater agreement were assessed using k statistics. Sensitivity, specificity, positive predictive value, and negative predictive value of ultrasound were calculated. RESULTS Agreement between ultrasound and MR imaging was fair to moderate: k of 0.27 (95% CI: 0.04, 0.50) and 0.44 (95% CI: 0.23, 0.65) for ultrasound raters 1 and 2, respectively. Inter-rater agreement between ultrasound graders 1 and 2 was moderate, with k of 0.56 (95% CI: 0.42, 0.70). Ultrasound sensitivities for infection were 0.13 and 0.09, while specificities were 0.94 and 0.98. Ultrasound sensitivities for polymeric wear were 0.38 and 0.62 with specificities of 0.90 and 0.76. CONCLUSION Ultrasound does not perform well in distinguishing patterns of synovitis either compared to MRI or a reference standard of aspiration/clinical follow-up.
Collapse
Affiliation(s)
- Ji Lin
- Department of Radiology and Imaging, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA.
| | - Alissa Burge
- Department of Radiology and Imaging, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA
| | - Qian Li
- Department of Radiology and Imaging, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA
| | - Christian Geannette
- Department of Radiology and Imaging, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA
| | - Theodore T Miller
- Department of Radiology and Imaging, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA
| |
Collapse
|
18
|
Coppola C, Greco M, Munir A, Musarò D, Quarta S, Massaro M, Lionetto MG, Maffia M. Osteoarthritis: Insights into Diagnosis, Pathophysiology, Therapeutic Avenues, and the Potential of Natural Extracts. Curr Issues Mol Biol 2024; 46:4063-4105. [PMID: 38785519 PMCID: PMC11119992 DOI: 10.3390/cimb46050251] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2024] [Revised: 04/05/2024] [Accepted: 04/18/2024] [Indexed: 05/25/2024] Open
Abstract
Osteoarthritis (OA) stands as a prevalent and progressively debilitating clinical condition globally, impacting joint structures and leading to their gradual deterioration through inflammatory mechanisms. While both non-modifiable and modifiable factors contribute to its onset, numerous aspects of OA pathophysiology remain elusive despite considerable research strides. Presently, diagnosis heavily relies on clinician expertise and meticulous differential diagnosis to exclude other joint-affecting conditions. Therapeutic approaches for OA predominantly focus on patient education for self-management alongside tailored exercise regimens, often complemented by various pharmacological interventions primarily targeting pain alleviation. However, pharmacological treatments typically exhibit short-term efficacy and local and/or systemic side effects, with prosthetic surgery being the ultimate resolution in severe cases. Thus, exploring the potential integration or substitution of conventional drug therapies with natural compounds and extracts emerges as a promising frontier in enhancing OA management. These alternatives offer improved safety profiles and possess the potential to target specific dysregulated pathways implicated in OA pathogenesis, thereby presenting a holistic approach to address the condition's complexities.
Collapse
Affiliation(s)
- Chiara Coppola
- Department of Mathematics and Physics “E. De Giorgi”, University of Salento, Via Lecce-Arnesano, 73100 Lecce, Italy; (C.C.); (A.M.)
| | - Marco Greco
- Department of Biological and Environmental Science and Technology, University of Salento, Via Lecce-Monteroni, 73100 Lecce, Italy; (M.G.); (D.M.); (S.Q.); (M.G.L.)
| | - Anas Munir
- Department of Mathematics and Physics “E. De Giorgi”, University of Salento, Via Lecce-Arnesano, 73100 Lecce, Italy; (C.C.); (A.M.)
| | - Debora Musarò
- Department of Biological and Environmental Science and Technology, University of Salento, Via Lecce-Monteroni, 73100 Lecce, Italy; (M.G.); (D.M.); (S.Q.); (M.G.L.)
| | - Stefano Quarta
- Department of Biological and Environmental Science and Technology, University of Salento, Via Lecce-Monteroni, 73100 Lecce, Italy; (M.G.); (D.M.); (S.Q.); (M.G.L.)
| | - Marika Massaro
- Institute of Clinical Physiology (IFC), National Research Council (CNR), 73100 Lecce, Italy;
| | - Maria Giulia Lionetto
- Department of Biological and Environmental Science and Technology, University of Salento, Via Lecce-Monteroni, 73100 Lecce, Italy; (M.G.); (D.M.); (S.Q.); (M.G.L.)
| | - Michele Maffia
- Department of Experimental Medicine, University of Salento, Via Lecce-Monteroni, 73100 Lecce, Italy
| |
Collapse
|
19
|
Konopitski AP, Jones H, Mathis KB, Noble PC, Rodriguez-Quintana D. Wearing a Surgical Vest With a Sterile Surgical Helmet System Decreases Contamination of the Surgical Field. J Arthroplasty 2024:S0883-5403(24)00414-5. [PMID: 38679349 DOI: 10.1016/j.arth.2024.04.066] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/14/2023] [Revised: 04/18/2024] [Accepted: 04/19/2024] [Indexed: 05/01/2024] Open
Abstract
BACKGROUND Sterile surgical helmet systems are frequently utilized in total knee arthroplasty procedures to protect the surgeon while maintaining a comfortable working environment. However, common helmet systems pressurize the space between the surgical gown and the surgeon's skin. In gowns with a back seam, this may allow contaminated skin particles to escape into the surgical field. By measuring bacterial colony-forming units (CFUs), this study sought to determine if occlusion of the open back seam reduced the risk of potential contamination. METHODS First, qualitative analysis depicting airflow variations between gown configurations was performed using the Schlieren Spherical Mirror imaging system. Each gown configuration consisted of a sterile surgical helmet and one of 3 gown configurations: a standard gown with rear-tied closure, a standard gown with a surgical vest, and a zippered Toga-style gown. Next, a surgeon then performed simulated surgical activities for 60 minutes within a 1.4 m3 isolation chamber with work surfaces and controllable filtered air exchanges. During each procedure, contaminated particles were collected on sets of agar settle plates positioned directly behind the surgeon. Upon completion, the agar plates were incubated in a biolab, and the number of bacterial and fungal CFUs was counted. The experimental procedure was repeated 12 times for each gown configuration, with sterilization of the chamber between runs. Contamination rates were expressed as CFUs/m2/h. RESULTS The mean contamination rate measured with the standard gown was 331.7 ± 52.0 CFU/m2/h. After the addition of a surgical vest, this rate decreased by 45% to 182.2 ± 30.8 CFU/m2/h (P = .02). Similarly, with the Toga-style gown, contamination rates dropped by 49% to 170.5 ± 41.9 CFU/m2/h (P = .01). CONCLUSIONS When used in conjunction with surgical helmet systems, conventional surgical gowns do not prevent potential contamination of the surgical field. We recommend that staff within the surgical field cover the back seam of standard gowns with a vest or don a zippered Toga-style gown.
Collapse
Affiliation(s)
- Andrew P Konopitski
- Department of Orthopaedic Surgery, St. Luke's University Health Network, Bethlehem, Pennsylvania
| | - Hugh Jones
- Department of Orthopaedic Surgery, McGovern School of Medicine, UTHealth Houston, Bellaire, Texas
| | - Kenneth B Mathis
- Department of Orthopaedic Surgery, McGovern School of Medicine, UTHealth Houston, Bellaire, Texas
| | - Philip C Noble
- Department of Orthopaedic Surgery, McGovern School of Medicine, UTHealth Houston, Bellaire, Texas
| | - David Rodriguez-Quintana
- Department of Orthopaedic Surgery, McGovern School of Medicine, UTHealth Houston, Bellaire, Texas
| |
Collapse
|
20
|
Muffly BT, Ayeni AM, Bonsu JM, Heo K, Premkumar A, Guild GN. Early Versus Late Periprosthetic Joint Infection After Total Knee Arthroplasty: Do Patient Differences Exist? J Arthroplasty 2024:S0883-5403(24)00384-X. [PMID: 38677341 DOI: 10.1016/j.arth.2024.04.061] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/25/2023] [Revised: 04/17/2024] [Accepted: 04/18/2024] [Indexed: 04/29/2024] Open
Abstract
BACKGROUND Periprosthetic joint infection (PJI) is a devastating complication following total knee arthroplasty (TKA). Little evidence exists comparing those with early versus late PJI. The purpose of the study was to determine comorbidity profile differences between patients developing early and late PJI. METHODS There were 72,659 patients undergoing primary TKA from 2009 to 2021, who were identified from a commercial claims and encounters database. Subjects diagnosed with PJI were categorized as either 'early' (within 90 days of index procedure) or 'late' (> 2 years after index arthroplasty). Non-infected patients within these periods served as control groups following 4:1 propensity score matching on other extraneous variables. Logistic regression analyses were performed comparing comorbidities between groups. RESULTS Patients were significantly younger in the late compared to the early infection group (58.1 versus 62.4 years, P < .001). When compared to those with early PJI, patients who had chronic kidney disease (13.3 versus 4.1%; OR [odds ratio] 5.17, P = .002), malignancy (20.4 versus 10.5%; OR 2.53, P = .009), uncomplicated diabetes (40.8 versus 30.6%; OR 2.00, P = .01), rheumatoid arthritis (9.2 versus 3.3%; OR 2.66, P = .046), and hypertension (88.8 versus 81.6%; OR 2.17, P = .04), were all significant predictors of developing a late PJI. CONCLUSIONS When compared to patients diagnosed with early PJI following primary TKA, the presence of chronic kidney disease, malignancy, uncomplicated diabetes, rheumatoid arthritis, and hypertension, were independent risk factors for the development of late PJI. Younger patients who have these comorbidities may be targets for preoperative optimization interventions that minimize the risk of PJI.
Collapse
Affiliation(s)
- Brian T Muffly
- Department of Orthopaedic Surgery, Emory University School of Medicine, Atlanta, Georgia
| | - Ayomide M Ayeni
- Department of Orthopaedic Surgery, Emory University School of Medicine, Atlanta, Georgia
| | - Janice M Bonsu
- Department of Orthopaedic Surgery, Emory University School of Medicine, Atlanta, Georgia
| | - Kevin Heo
- Department of Orthopaedic Surgery, Emory University School of Medicine, Atlanta, Georgia
| | - Ajay Premkumar
- Department of Orthopaedic Surgery, Emory University School of Medicine, Atlanta, Georgia
| | - George N Guild
- Department of Orthopaedic Surgery, Emory University School of Medicine, Atlanta, Georgia
| |
Collapse
|
21
|
Schreiner MM, Straub J, Apprich S, Staats K, Windhager R, Aletaha D, Böhler C. The influence of biological DMARDs on aseptic arthroplasty loosening: a retrospective cohort study. Rheumatology (Oxford) 2024; 63:970-976. [PMID: 37402609 PMCID: PMC10986799 DOI: 10.1093/rheumatology/kead304] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2023] [Revised: 05/21/2023] [Accepted: 06/08/2023] [Indexed: 07/06/2023] Open
Abstract
OBJECTIVE To investigate whether biological DMARDs affect the risk of aseptic loosening after total hip/knee arthroplasty (THA/TKA) in patients with RA. METHODS We retrospectively identified all patients suffering from RA who underwent THA/TKA at our academic centre between 2002 and 2015 and linked them with an existing prospective observational RA database at our institution. The risk of aseptic loosening was estimated using radiological signs of component loosening (RCL). A time-dependent Cox regression analysis was used to compare the risk of implant loosening between patients treated with traditional DMARDS and biological DMARDs, or alternately both over time. RESULTS A total of 155 consecutive total joint arthroplasties (TJAs) (103 TKA vs 52 THA) was retrospectively included in the study. Mean age at implantation was 59 ± 13 years. Mean follow-up time was 69 ± 43 months. Overall, 48 (31%) TJAs showed signs of RCL, with 28 (27.2%) RCLs occurring after TKA compared with 20 after THA (38.5%). A significant difference regarding the incidence of RCL between the traditional DMARDs group (39 cases of RCL, 35%) and the biological DMARDs group (nine cases of RCL, 21%) (P = 0.026) was observed using the log-rank test. This was also true when using a time-dependent Cox regression with therapy as well as arthroplasty location (hip vs knee) as variables (P = 0.0447). CONCLUSION Biological DMARDs may reduce the incidence of aseptic loosening after TJA in patients with RA compared with traditional DMARDs. This effect seems to be more pronounced after TKA than THA.
Collapse
Affiliation(s)
- Markus M Schreiner
- Department of Orthopedics and Trauma Surgery, Medical University of Vienna, Vienna, Austria
| | - Jennifer Straub
- Department of Orthopedics and Trauma Surgery, Medical University of Vienna, Vienna, Austria
| | - Sebastian Apprich
- Department of Orthopedics and Trauma Surgery, Medical University of Vienna, Vienna, Austria
| | - Kevin Staats
- Department of Orthopedics and Trauma Surgery, Medical University of Vienna, Vienna, Austria
| | - Reinhard Windhager
- Department of Orthopedics and Trauma Surgery, Medical University of Vienna, Vienna, Austria
| | - Daniel Aletaha
- Department of Rheumatology, Medical University of Vienna, Vienna, Austria
| | - Christoph Böhler
- Department of Orthopedics and Trauma Surgery, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
22
|
Laperche JM, Chang K, Albright JA, Ibrahim Z, Zhang H, Daniels AH, Barrett TJ. Shoulder Adhesive Capsulitis Prior to Total Knee Arthroplasty is Associated With Increased Rates of Postoperative Stiffness Requiring Manipulation Under Anesthesia and Arthroscopic Lysis of Adhesions. J Arthroplasty 2024; 39:960-965. [PMID: 37924990 DOI: 10.1016/j.arth.2023.10.051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Revised: 10/23/2023] [Accepted: 10/26/2023] [Indexed: 11/06/2023] Open
Abstract
BACKGROUND Arthrofibrosis following total knee arthroplasty (TKA) and adhesive capsulitis (AC) of the shoulder develop via a similar pathologic process. The purpose of this study was to examine the relationship between these two conditions. METHODS This was a retrospective cohort study using a large nationwide claims database. Patients who had a history of shoulder AC prior to TKA were compared to TKA patients who did not have AC history comparing rates of postoperative stiffness, manipulation under anesthesia (MUA), arthroscopic lysis of adhesions (LOAs), and revision arthroplasty at postoperative timepoints (3 months, 6 months, 1 year, and 2 years). RESULTS Within 3 months, 6 months, 1 year, and 2 years of their TKAs, patients who had a history of AC prior to TKA were significantly more likely to experience stiffness (OR [odds ratio] = 1.29, 1.28, 1.32, and 1.36, respectively) and LOAs (OR = 6.78, 3.65, 2.99, and 2.81, respectively). They also showed increased risk of MUA within 6 months, 1 year, and 2 years (OR = 1.15, 1.15, and 1.16, respectively) of their TKAs. Patients having a preoperative diagnosis of AC did not have an increased risk of undergoing revision surgery 1 year or 2 years after their TKAs (P > .05). CONCLUSIONS Patients diagnosed with AC prior to TKA experience higher rates of postoperative stiffness, resulting in additional interventions such as MUA and LOAs. These findings identify a particularly high-risk patient population that may benefit from additional interventions prior to and following TKA. LEVEL OF EVIDENCE This is a level III prognostic study.
Collapse
Affiliation(s)
- Jacob M Laperche
- Frank H. Netter School of Medicine, Quinnipiac University, North Haven, Connecticut; Department of Orthopedic Surgery, University Orthopedics, Providence, Rhode Island
| | - Kenny Chang
- The Warren Alpert Medical School of Brown University, Providence, Rhode Island
| | - James A Albright
- The Warren Alpert Medical School of Brown University, Providence, Rhode Island
| | - Zainab Ibrahim
- Department of Orthopaedic Surgery, Brown University, Providence, Rhode Island
| | - Helen Zhang
- The Warren Alpert Medical School of Brown University, Providence, Rhode Island
| | - Alan H Daniels
- Department of Orthopedic Surgery, University Orthopedics, Providence, Rhode Island; Department of Orthopaedic Surgery, Brown University, Providence, Rhode Island
| | - Thomas J Barrett
- Department of Orthopedic Surgery, University Orthopedics, Providence, Rhode Island; Department of Orthopaedic Surgery, Brown University, Providence, Rhode Island
| |
Collapse
|
23
|
Borsinger TM, Quevedo Gonzalez FJ, Pagan CA, Karasavvidis T, Sculco PK, Wright TM, Kahlenberg CA, Lipman JD, Debbi EM, Vigdorchik JM, Mayman DJ. Is Tibial Bone Mineral Density Related to Sex, Age, Preoperative Alignment, or Fixation Method in Primary Total Knee Arthroplasty? J Arthroplasty 2024:S0883-5403(24)00272-9. [PMID: 38548236 DOI: 10.1016/j.arth.2024.03.056] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Revised: 03/18/2024] [Accepted: 03/20/2024] [Indexed: 04/23/2024] Open
Abstract
BACKGROUND Cementless total knee arthroplasty (TKA) has regained interest for its potential for long-term biologic fixation. The density of the bone is related to its ability to resist static and cyclic loading and can affect long-term implant fixation; however, little is known about the density distribution of periarticular bone in TKA patients. Thus, we sought to characterize the bone mineral density (BMD) of the proximal tibia in TKA patients. METHODS We included 42 women and 50 men (mean age 63 years, range: 50 to 87; mean body mass index 31.6, range: 20.5 to 49.1) who underwent robotic-assisted TKA and had preoperative computed tomography scans with a BMD calibration phantom. Using the robotic surgical plan, we computed the BMD distribution at 1 mm-spaced cross-sections parallel to the tibial cut from 2 mm above the cut to 10 mm below. The BMD was analyzed with respect to patient sex, age, preoperative alignment, and type of fixation. RESULTS The BMD decreased from proximal to distal. The greatest changes occurred within ± 2 mm of the tibial cut. Age did not affect BMD for men; however, women between 60 and 70 years had higher BMD than women ≥ 70 years for the total cut (P = .03) and the medial half of the cut (P = .03). Cemented implants were used in 1 86-year-old man and 18 women (seven < 60 years, seven 60 to 70 years, and four ≥ 70 year old). We found only BMD differences between cemented or cementless fixation for women < 60 years. CONCLUSIONS To our knowledge, this is the first study to characterize the preoperative BMD distribution in TKA patients relative to the intraoperative tibial cut. Our results indicate that while sex and age may be useful surrogates of BMD, the clinically relevant thresholds for cementless knees remain unclear, offering an area for future studies.
Collapse
Affiliation(s)
- Tracy M Borsinger
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, New York
| | | | - Cale A Pagan
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, New York
| | - Theofilos Karasavvidis
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, New York
| | - Peter K Sculco
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, New York
| | - Timothy M Wright
- Department of Biomechanics, Hospital for Special Surgery, New York, New York
| | - Cynthia A Kahlenberg
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, New York
| | - Joseph D Lipman
- Department of Biomechanics, Hospital for Special Surgery, New York, New York
| | - Eytan M Debbi
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, New York
| | - Jonathan M Vigdorchik
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, New York
| | - David J Mayman
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, New York
| |
Collapse
|
24
|
Saeed AZ, Khaleeq T, Ahmed U, Ajula R, Boutefnouchet T, D'Alessandro P, Malik SS. No clinical advantage with customized individually made implants over conventional off-the-shelf implants in total knee arthroplasty: a systematic review and meta-analysis. Arch Orthop Trauma Surg 2024; 144:1311-1330. [PMID: 37979098 DOI: 10.1007/s00402-023-05090-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Accepted: 09/25/2023] [Indexed: 11/19/2023]
Abstract
INTRODUCTION Total knee arthroplasty (TKA) can be performed with either conventional off-the-shelf (OTS) or customized individually-made (CIM) implants. The evidence for CIM implants is limited and variable, and the aim of this review was to compare clinical and radiological outcomes between CIM and OTS implants. METHODS A systematic review and meta-analysis were conducted in accordance with PRISMA guidelines. Studies reporting on clinical, radiological, or alignment outcomes for CIM and OTS implants were selected. The studies were appraised using the Methodical index for non-randomized studies tool. RESULTS Twenty-three studies fulfilled the inclusion criteria. The studies comprised 2856 CIM and 1877 OTS TKAs. Revision rate was higher with CIM (5.9%) compared to OTS (3.7%) implants [OR 1.23(95% CI 0.69-2.18)]. Manipulation under anesthesia (MUA) was higher in CIM (2.2%) compared to OTS (1.1%) group [OR 2.95(95% CI 0.95-9.13)] and complications rate was higher in CIM (5%) vs. OTS (4.5%) [OR 1.45(95% CI 0.53-3.96)] but neither reached statistical significance. Length of stay was significantly shorter in CIM group 2.9 days vs. 3.5 days [MD - 0.51(95% CI - 0.82 to - 0.20)]. Knee Society Score showed no difference between CIM and OTS groups for Knee 90.5 vs. 90.6 [MD - 0.27(95% CI - 4.27 to 3.73)] and Function 86.1 vs. 83.1 [MD 1.51(95% CI - 3.69 to 6.70)]. CONCLUSION CIM implants in TKA have theoretical benefits over OTS prostheses. However, in this present review, CIM implants were associated with higher revisions, MUA, and overall complication rates. There was no difference in outcome score and CIM implants did not improve overall target alignment; however, more CIM TKAs were found to be in the HKA target zone compared to OTS TKAs. The findings of this review do not support the general utilization of CIM over OTS implants in TKA.
Collapse
Affiliation(s)
- Abu Z Saeed
- The Robert Jones and Agnes Hunt Orthopaedic Hospital, Gobowen, Oswestry, SY10 7AG, UK.
| | - Tahir Khaleeq
- The Robert Jones and Agnes Hunt Orthopaedic Hospital, Gobowen, Oswestry, SY10 7AG, UK
| | - Usman Ahmed
- Worcestershire Acute Hospitals NHS Trust, Worcester, UK
| | - Randeep Ajula
- University Hospitals of Leicester NHS Trust, Leicester, UK
| | | | - Peter D'Alessandro
- Orthopaedic Research Foundation of Western Australia, Medical School, Discipline of Surgery, University of Western Australia, Perth, Australia
| | | |
Collapse
|
25
|
Pondugula P, Krumme JW, Seedat R, Patel NK, Golladay GJ. Evaluation of painful total knee arthroplasty: an approach based on common etiologies for total knee arthroplasty revision. Musculoskelet Surg 2024; 108:11-20. [PMID: 37987959 DOI: 10.1007/s12306-023-00800-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Accepted: 10/24/2023] [Indexed: 11/22/2023]
Abstract
A differential diagnosis with emphasis on the common indications for revision should be utilized in the workup of painful total knee arthroplasty (TKA). The physician should identify the exact etiology of the patient's pain to maximize outcomes from treatment. Evaluation for infection should be completed using the Musculoskeletal Infection Society (MSIS) criteria. When common causes of revision TKA do not appear to be the cause of the pain, less likely causes should be not be ignored. Further advancements such as pressure sensing devices may be able to improve patient satisfaction and decrease the incidence of pain following TKA.
Collapse
Affiliation(s)
- P Pondugula
- Department of Orthopedic Surgery, Virginia Commonwealth University Medical Center, PO Box 980153, Richmond, VA, 23298, USA
| | - J W Krumme
- Department of Orthopedic Surgery, Virginia Commonwealth University Medical Center, PO Box 980153, Richmond, VA, 23298, USA
| | - R Seedat
- Department of Orthopedic Surgery, Virginia Commonwealth University Medical Center, PO Box 980153, Richmond, VA, 23298, USA
| | - N K Patel
- Department of Orthopedic Surgery, Virginia Commonwealth University Medical Center, PO Box 980153, Richmond, VA, 23298, USA
| | - G J Golladay
- Department of Orthopedic Surgery, Virginia Commonwealth University Medical Center, PO Box 980153, Richmond, VA, 23298, USA.
| |
Collapse
|
26
|
Ailaney N, Barra MF, Schloemann DT, Thirukumaran CP, Kaplan NB. Short-Term (6 Months or Less) Pain in Cemented versus Cementless Total Knee Arthroplasty: A Systematic Review and Meta-Analysis. J Arthroplasty 2024:S0883-5403(24)00134-7. [PMID: 38387768 DOI: 10.1016/j.arth.2024.02.033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Revised: 02/11/2024] [Accepted: 02/13/2024] [Indexed: 02/24/2024] Open
Abstract
BACKGROUND Cementless total knee arthroplasty (TKA) has increased in popularity to potentially improve survivorship. Radiostereometric studies demonstrate increased component migration during the first 3 to 6 months in cementless constructs, generating concern for increased postoperative pain during early osseointegration. The purpose of this study was to evaluate short-term (≤ 6 months) pain and function in cemented versus cementless TKA. We hypothesized that cementless TKA patients report increased pain during the short-term (≤ 6 months) postoperative period. METHODS The MEDLINE, EMBASE, CINAHL, and Cochrane Libraries were searched for studies evaluating short-term (≤ 6 months) outcomes of cemented versus cementless primary TKA. Studies involving hybrid fixation were excluded. A meta-analysis was performed using standardized mean difference for primary outcomes (early postoperative pain) and weighted mean difference (WMD) for secondary outcomes (early postoperative function). RESULTS There were eleven studies included. There was no significant difference in acute postoperative pain between cemented and cementless TKA within 6 months of index TKA (standardized mean difference 0.08 in favor of cemented TKA; P = .10). Early postoperative forgotten joint scores (WMD 0.81; P = .81) and knee injury and osteoarthritis outcome scores for joint replacement (WMD 0.80 in favor of cemented TKA; P = .14) were also similar between groups. CONCLUSIONS There is no difference in short-term (≤ 6 months) pain or early function between patients receiving cemented and cementless TKA. This suggests that surgeons may utilize cementless TKA without fear of increased pain due to micromotion within 6 months of index arthroplasty. However, additional studies with uniform assessment methods are needed to further inform differences in short-term pain and early functional outcomes between cemented and cementless TKA.
Collapse
Affiliation(s)
- Nikhil Ailaney
- Department of Orthopaedic Surgery, University of Rochester Medical Center, Rochester, New York
| | - Matthew F Barra
- Department of Orthopaedic Surgery, University of Rochester Medical Center, Rochester, New York
| | - Derek T Schloemann
- Department of Orthopaedic Surgery, University of Rochester Medical Center, Rochester, New York
| | - Caroline P Thirukumaran
- Department of Orthopaedic Surgery, University of Rochester Medical Center, Rochester, New York
| | - Nathan B Kaplan
- Department of Orthopaedic Surgery, University of Rochester Medical Center, Rochester, New York
| |
Collapse
|
27
|
Kirchner GJ, Stambough JB, Jimenez E, Nikkel LE. Robotic-assisted TKA is Not Associated With Decreased Odds of Early Revision: An Analysis of the American Joint Replacement Registry. Clin Orthop Relat Res 2024; 482:303-310. [PMID: 37962943 PMCID: PMC10776156 DOI: 10.1097/corr.0000000000002783] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Accepted: 06/27/2023] [Indexed: 11/15/2023]
Abstract
BACKGROUND Robotic-assisted TKA continues to see wider clinical use, despite limited knowledge of its impact on patient satisfaction and implant survival. Most studies to date have presented small cohorts and came from single-surgeon or single-center experiences. Therefore, a population-level comparison of revision rates between robotic-assisted and conventional TKA in the registry setting may help arthroplasty surgeons better define whether robotic assistance provides a meaningful advantage compared with the conventional technique. QUESTIONS/PURPOSES (1) After controlling for confounding variables, such as surgeon, location of surgery, and patient comorbidity profile, were robotic-assisted TKAs less likely than conventional TKAs to result in revision for any reason at 2 years? (2) After again controlling for confounding variables, were robotic-assisted TKAs less likely to result in any specific reasons for revision than the conventional technique at 2 years? METHODS The American Joint Replacement Registry was used to identify patients 65 years or older who underwent TKA between January 2017 and March 2020 with a minimum of 2 years of follow-up. Patients were limited to age 65 yeas or older to link TKAs to Medicare claims data. Two retrospective cohorts were created: robotic-assisted TKA and conventional TKA. Patient demographic variables included in the analysis were age, gender, BMI, and race. Additional characteristics included the Charlson comorbidity index, anesthesia type, year of the index procedure, and length of stay. A total of 10% (14,216 of 142,550) of TKAs performed during this study period used robotics. Patients with robotic-assisted TKA and those with conventional TKA were similar regarding age (73 ± 6 years versus 73 ± 6 years; p = 0.31) and gender (62% [8736 of 14,126] versus 62% [79,399 of 128,334] women; p = 0.34). A multivariable, mixed-effects logistic regression model was created to analyze the odds of all-cause revision as a factor of robot use, and a logistic regression model was created to investigate specific revision diagnoses. RESULTS After controlling for potentially confounding variables, such as surgeon, location of surgery, and Charlson comorbidity index, we found no difference between the robotic-assisted and conventional TKAs in terms of the odds of revision at 2 years (OR of robotic-assisted versus conventional TKA 1.0 [95% CI 0.8 to 1.3]; p = 0.92). The reasons for revision of robotic-assisted TKA did not differ from those of conventional TKA, except for an increased odds of instability (OR 1.6 [95% CI 1.0 to 2.4]; p = 0.04) and pain (OR 2.1 [95% CI 1.4 to 3.0]; p < 0.001) in the robotic-assisted cohort. CONCLUSION In light of these findings, surgeons should not assume that robotic assistance in TKA will lead to improved early implant survival. Our findings do not support an improvement over conventional TKA with robotic assistance with regards to common causes of early revisions such malalignment, malposition, stiffness, pain, and instability, and in some cases, suggest there is a benefit to conventional TKA. Differences in the mid-term and long-term revision risk with conventional versus robotic-assisted TKA remain unknown. Appropriate informed consent around the use of robotic assistance should not imply decreased early revision risk. LEVEL OF EVIDENCE Level III, therapeutic study.
Collapse
Affiliation(s)
- Gregory J. Kirchner
- Department of Orthopaedics and Rehabilitation, Penn State Milton S. Hershey Medical Center, Hershey, PA, USA
| | - Jeffrey B. Stambough
- Department of Orthopaedic Surgery, University of Arkansas for Medical Sciences, Little Rock, AR, USA
| | - Emily Jimenez
- American Academy of Orthopaedic Surgeons, Rosemont, IL, USA
| | - Lucas E. Nikkel
- Department of Orthopaedic Surgery, Johns Hopkins Medicine, Columbia, MD, USA
| |
Collapse
|
28
|
Al-Nasser S, Noroozi S, Harvey A, Aslani N, Haratian R. Exploring the Performance of an Artificial Intelligence-Based Load Sensor for Total Knee Replacements. SENSORS (BASEL, SWITZERLAND) 2024; 24:585. [PMID: 38257676 PMCID: PMC10821047 DOI: 10.3390/s24020585] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Revised: 01/11/2024] [Accepted: 01/15/2024] [Indexed: 01/24/2024]
Abstract
Using tibial sensors in total knee replacements (TKRs) can enhance patient outcomes and reduce early revision surgeries, benefitting hospitals, the National Health Services (NHS), stakeholders, biomedical companies, surgeons, and patients. Having a sensor that is accurate, precise (over the whole surface), and includes a wide range of loads is important to the success of joint force tracking. This research aims to investigate the accuracy of a novel intraoperative load sensor for use in TKRs. This research used a self-developed load sensor and artificial intelligence (AI). The sensor is compatible with Zimmer's Persona Knee System and adaptable to other knee systems. Accuracy and precision were assessed, comparing medial/lateral compartments inside/outside the sensing area and below/within the training load range. Five points were tested on both sides (medial and lateral), inside and outside of the sensing region, and with a range of loads. The average accuracy of the sensor was 83.41% and 84.63% for the load and location predictions, respectively. The highest accuracy, 99.20%, was recorded from inside the sensing area within the training load values, suggesting that expanding the training load range could enhance overall accuracy. The main outcomes were that (1) the load and location predictions were similar in accuracy and precision (p > 0.05) in both compartments, (2) the accuracy and precision of both predictions inside versus outside of the triangular sensing area were comparable (p > 0.05), and (3) there was a significant difference in the accuracy of load and location predictions (p < 0.05) when the load applied was below the training loading range. The intraoperative load sensor demonstrated good accuracy and precision over the whole surface and over a wide range of load values. Minor improvements to the software could greatly improve the results of the sensor. Having a reliable and robust sensor could greatly improve advancements in all joint surgeries.
Collapse
Affiliation(s)
- Samira Al-Nasser
- Bournemouth University, Fern Barrow, Poole BH12 3BB, UK; (S.A.-N.); (R.H.)
| | - Siamak Noroozi
- Bournemouth University, Fern Barrow, Poole BH12 3BB, UK; (S.A.-N.); (R.H.)
| | - Adrian Harvey
- Royal Bournemouth Hospital, Castle Ln E, Bournemouth BH7 7DW, UK;
| | - Navid Aslani
- Innovid Tech Ltd., 107b Athenlay Road, London SE15 3EJ, UK;
| | - Roya Haratian
- Bournemouth University, Fern Barrow, Poole BH12 3BB, UK; (S.A.-N.); (R.H.)
| |
Collapse
|
29
|
Bundschuh KE, Muffly BT, Ayeni AM, Heo KY, Khawaja SR, Tocio AJ, Karzon AL, Premkumar A, Guild GN. Should All Patients Receive Extended Oral Antibiotic Prophylaxis? Defining Its Role in Patients Undergoing Primary and Aseptic Revision Total Joint Arthroplasty. J Arthroplasty 2024:S0883-5403(24)00012-3. [PMID: 38218558 DOI: 10.1016/j.arth.2024.01.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/01/2023] [Revised: 12/28/2023] [Accepted: 01/07/2024] [Indexed: 01/15/2024] Open
Abstract
BACKGROUND Prior studies have demonstrated reduced periprosthetic joint infection (PJI) rates following extended oral antibiotics (EOAs) for high-risk patients undergoing primary total joint arthroplasty (TJA). This study compared 3-month PJI rates in all patients undergoing primary or aseptic revision TJA with or without EOA prophylaxis. METHODS In total, 2,982 consecutive primary (n = 2,677) and aseptic revision (n = 305) TJAs were performed by a single, fellowship-trained arthroplasty surgeon from 2016 to 2022 were retrospectively reviewed. Beginning January 2020, all patients received 7 days of 300 mg oral cefdinir twice daily immediately postoperatively. Rates of PJI at 3 months were compared between patients who received or did not receive EOA. RESULTS Rates of PJI at 3 months in patients undergoing primary and aseptic revision TJA were significantly lower in those receiving EOA prophylaxis compared to those who did not (0.41 versus 1.13%, respectively; P = .02). After primary TJA, lower PJI rates were observed with EOA prophylaxis utilization (0.23 versus 0.74%, P = .04; odds ratio [OR] 3.85). Following aseptic revision TJA, PJI rates trended toward a significant decrease with the EOA compared to without (1.88 versus 4.83%, respectively; P = .16; OR 2.71). CONCLUSIONS All patients undergoing primary or aseptic revision TJA who received EOA prophylaxis were 3.85 and 2.71 times less likely, respectively, to develop PJI at 3 months compared to those without EOA. Future studies are needed to determine if these results are maintained at postoperative time periods beyond 3 months following primary TJA. LEVEL OF EVIDENCE III, Retrospective review.
Collapse
Affiliation(s)
- Kyle E Bundschuh
- Department of Orthopaedic Surgery, Investigation performed at Emory University, Atlanta, Georgia
| | - Brian T Muffly
- Department of Orthopaedic Surgery, Investigation performed at Emory University, Atlanta, Georgia
| | - Ayomide M Ayeni
- Department of Orthopaedic Surgery, Investigation performed at Emory University, Atlanta, Georgia
| | - Kevin Y Heo
- Department of Orthopaedic Surgery, Investigation performed at Emory University, Atlanta, Georgia
| | - Sameer R Khawaja
- Department of Orthopaedic Surgery, Investigation performed at Emory University, Atlanta, Georgia
| | - Adam J Tocio
- Department of Orthopaedic Surgery, Investigation performed at Emory University, Atlanta, Georgia
| | - Anthony L Karzon
- Department of Orthopaedic Surgery, Investigation performed at Emory University, Atlanta, Georgia
| | - Ajay Premkumar
- Department of Orthopaedic Surgery, Investigation performed at Emory University, Atlanta, Georgia
| | - George N Guild
- Department of Orthopaedic Surgery, Investigation performed at Emory University, Atlanta, Georgia
| |
Collapse
|
30
|
Wautier D, Thienpont E. Tibial implant design in primary TKA: retrospective comparison of two designs for the occurrence of radiolucent lines and aseptic loosening. Arch Orthop Trauma Surg 2024; 144:323-332. [PMID: 37733127 DOI: 10.1007/s00402-023-05030-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Accepted: 08/09/2023] [Indexed: 09/22/2023]
Abstract
INTRODUCTION The purpose of this retrospective study was to study the effect of tibial implant design on the occurrence of radiolucent lines (RLLs) and aseptic loosening (AL) by comparing two different total knee arthroplasty (TKA) designs. MATERIALS AND METHODS Two types of total knee arthroplasty, different for tibial shape, size and keel design were compared, 255 for the first and 774 for the second. The occurrence of RLLs and radiological signs of micro- and macro-mobility and aseptic loosening was analyzed. Demographic data were compared, as well as the type and rate of RLLs, occurrence of aseptic loosening and the presence of potential risk factors. RESULTS The first implant design is morphometric and has a squarer keel than the second implant TKA. The overall rate of RLLs was similar (21% vs 23%), despite of a significantly lower rates of radiological signs of macro-mobility of the tibial component with the first implant (2% vs 17%). Survivorship of both designs was overall comparable (99.6% vs 98.8 %) the first implant group had more potential risk factors for poor bone quality than the second group (p < 0.05). CONCLUSION A morphometric design is more anatomic and offers better bone coverage of the epiphyseal tibial surface. RLLs, as a sign of implant micro-mobility, were equally present in both designs. Radiological signs of macro-mobility at the metaphysis were less frequently observed in squared keel design. The morphometric implant did not show improved survivorship compared with a symmetric implant. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- D Wautier
- Department of Orthopedic Surgery, CHU UCL Namur, Godinne, Avenue Docteur Gaston Therasse 1, 5530, Yvoir, Belgium.
| | - E Thienpont
- Department of Orthopedic Surgery, Cliniques Universitaires Saint-Luc, Avenue Hippocrate 10, 1200, Brussels, Belgium
| |
Collapse
|
31
|
Pijls BG. Technology assistance in primary total knee replacement: hype or hope? Expert Rev Med Devices 2024; 21:11-14. [PMID: 37992036 DOI: 10.1080/17434440.2023.2287576] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2023] [Accepted: 11/21/2023] [Indexed: 11/24/2023]
Abstract
INTRODUCTION Total knee replacement (TKR) reduces pain, it increases quality of life and it generally lasts a long time with revision rates of less than 5% at 10 years. Some authors have suggested that outcomes may be further improved by technology assistance. AREAS COVERED Technology assistance in primary TKR includes technologies such as navigated TKR, patient specific instrumentation TKR and robotic TKR. EXPERT OPINION In general, technology assistance results in higher accuracy of component positioning and alignment, but this is likely not clinically relevant as no clinically important difference in clinical outcomes, quality of life and complications such as revisions has been demonstrated in meta-analyses of randomized controlled trials. As technology assistance in primary TKR is increasingly used to capture patient and surgeon data, surgeons have an increasingly important role in protecting their patients' data and their own data. Real world evidence of implant registries has shown that TKR without technologically assistance can achieve perfectly acceptable outcomes. Although there is a genuine hope that technology-assisted TKR may further improve these outcomes, this hope is based on promises rather than solid evidence. At the same time, technology assisted TKR is heavily promoted including direct patient marketing, which are aspects of a hype.
Collapse
Affiliation(s)
- Bart G Pijls
- Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|
32
|
Matar HE, Bawale R, Gollish JD. High Survivorship of Hybrid Fixation Technique in Aseptic Condylar Revision Total Knee Arthroplasty with Minimal Metaphyseal Bone Loss: 5-10 Year Clinical Outcomes. J Long Term Eff Med Implants 2024; 34:41-47. [PMID: 37938204 DOI: 10.1615/jlongtermeffmedimplants.2023047031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2023]
Abstract
The aim of this study was to evaluate the outcomes of hybrid fixation technique in aseptic condylar revision total knee arthroplasty (rTKA). A retrospective consecutive study of patients with minimal metaphyseal bone loss who underwent aseptic rTKA with press-fit cementless femoral stems and short cemented tibial stems. Primary outcome measure was mechanical failure. Surgical complications, reoperations and revision for any cause were collected and Knee society score at final follow-up. Kaplan-Meier survival curves were used to estimate implant survivorship. Seventy-three patients were included with minimum 5 years follow-up with a mean age of 74.5 years. At mean follow-up of 8.5 years (range 5-10), only two patients required revision, both for infection. Radiographic evaluation was undertaken for all remaining patients at final follow-up and showed no evidence of mechanical failure. Six patients (8.4%) showed non-progressive radiolucent lines around the cementless femoral stem with only one having a pedestal at the tip of the femoral stem and four patients (5.6%) showed non-progressive radiolucent lines around the cemented tibial stem. Mean KSS score was 80.6 (standard deviation 13.8) indicating satisfactory clinical outcomes. Using "any cause implant revision" as an end point, implant survivorship for this construct was 97.3% at mean 8.5 years. In our experience, a hybrid fixation technique with a press-fit cementless femoral stem and a short-cemented tibial stemmed construct achieves excellent medium- to long-term outcomes in aseptic condylar revision cases with minimal metaphyseal bone loss.
Collapse
Affiliation(s)
- Hosam E Matar
- Nottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham NG5 1PB, UK; Sunnybrook Holland Centre, University of Toronto, Toronto, Canada
| | - Rajesh Bawale
- Sunnybrook Holland Centre, University of Toronto, Toronto, Canada
| | - Jeffrey D Gollish
- Holland Orthopaedic and Arthritic Centre, Sunnybrook Health Sciences, Toronto, Canada
| |
Collapse
|
33
|
Soltanihafshejani N, Bitter T, Verdonschot N, Janssen D. The effect of periprosthetic bone loss on the failure risk of tibial total knee arthroplasty. J Orthop Res 2024; 42:90-99. [PMID: 37292040 DOI: 10.1002/jor.25642] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 05/02/2023] [Accepted: 06/07/2023] [Indexed: 06/10/2023]
Abstract
The effect of long-term periprosthetic bone loss on the process of aseptic loosening of tibial total knee arthroplasty (TKA) is subject to debate. Contradicting studies can be found in literature, reporting either bone resorption or bone formation before failure of the tibial tray. The aim of the current study was to investigate the effects of bone resorption on failure of tibial TKA, by simulating clinical postoperative bone density changes in finite element analysis (FEA) models and FEA models were created of two tibiae representing cases with good and poor initial bone quality which were subjected to a walking configuration and subsequently to a traumatic stumbling load. Bone failure was simulated using a crushable foam model incorporating progressive yielding. Repetitive loading under a level walking load did not result in failure of the periprosthetic bone in neither the good nor poor bone quality tibia at the baseline bone densities. When applying a stumble load, a collapse of the tibial reconstruction was noticed in the poor bone quality model. Incorporating postoperative bone loss led to a significant increase of the failure risk, particularly for the poor bone quality model in which subsidence of the tibial component was substantial. Our results suggest bone loss can lead to an increased risk of a collapse of the tibial component, particularly in case of poor bone quality at the time of surgery. The study also examined the probability of medial or lateral subsidence of the implant and aimed to improve clinical implications. The FEA model simulated plastic deformation of the bone and implant subsidence, with further validation required via mechanical experiments.
Collapse
Affiliation(s)
- Navid Soltanihafshejani
- Orthopaedic Research Laboratory, Institute for Health Sciences, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Thom Bitter
- Orthopaedic Research Laboratory, Institute for Health Sciences, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Nico Verdonschot
- Orthopaedic Research Laboratory, Institute for Health Sciences, Radboud University Medical Center, Nijmegen, The Netherlands
- Laboratory for Biomechanical Engineering, Faculty of Engineering Technology, University of Twente, Enschede, The Netherlands
| | - Dennis Janssen
- Orthopaedic Research Laboratory, Institute for Health Sciences, Radboud University Medical Center, Nijmegen, The Netherlands
| |
Collapse
|
34
|
Ehioghae M, Montoya A, Keshav R, Vippa TK, Manuk-Hakobyan H, Hasoon J, Kaye AD, Urits I. Effectiveness of Virtual Reality-Based Rehabilitation Interventions in Improving Postoperative Outcomes for Orthopedic Surgery Patients. Curr Pain Headache Rep 2024; 28:37-45. [PMID: 38032538 DOI: 10.1007/s11916-023-01192-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/20/2023] [Indexed: 12/01/2023]
Abstract
PURPOSE OF REVIEW The surge in orthopedic surgeries strains the US healthcare system, necessitating innovative rehabilitation solutions. This review examines the potential of virtual reality (VR)-based interventions for orthopedic rehabilitation. RECENT FINDINGS The effectiveness of VR-based interventions in orthopedic surgery patients is scrutinized. While some studies suggest better patient-reported outcomes and satisfaction, mixed results emerge from others, demonstrating comparable or varied results compared to traditional rehabilitation. The underlying mechanisms of VR-based rehabilitation are elucidated, showing its positive impact on proprioception, pain management, agency, and balance. Challenges of unfamiliarity, patient engagement, and drop-out rates are identified, emphasizing the need for tailored approaches. VR technology's immersive environments and multisensory experiences offer a novel approach to addressing functional deficits and pain post-surgery. The conclusion drawn is that VR-based rehabilitation complements rather than replaces conventional methods, potentially aiding in pain reduction and functional improvement. VR-based rehabilitation holds promise for enhancing orthopedic surgery outcomes, presenting a dynamic approach to recovery. Its potential to reshape healthcare delivery and reimbursement structures underscores its significance in modern healthcare. Overall, VR-based rehabilitation offers a promising avenue for optimizing postoperative recovery in orthopedic surgery patients.
Collapse
Affiliation(s)
- Mark Ehioghae
- Medical College of Wisconsin, 8701 W Watertown Plank Rd, Milwaukee, WI, 53226, USA.
| | - Alexis Montoya
- , Eastern Virginia Medical School 825 Fairfax Ave, Norfolk, VA, 23507, USA
| | - Ritwik Keshav
- , Eastern Virginia Medical School 825 Fairfax Ave, Norfolk, VA, 23507, USA
| | - Tarun K Vippa
- University of Arizona College of Medicine-Phoenix, 475 N 5th St, Phoenix, AZ, 85004, USA
| | - Hayk Manuk-Hakobyan
- Cedars Sinai Medical Center, 8700 Beverly Blvd #5725, Los Angeles, CA, 90048, USA
| | - Jamal Hasoon
- McGovern Medical School, The University of Texas Health Science Center at Houston, 7000 Fannin Street, Houston, TX, 77030, USA
| | - Alan D Kaye
- Louisiana State University Health Shreveport, 1501 Kings Highway, Shreveport, LA, 71103, USA
| | - Ivan Urits
- Southcoast Health Pain Management, 100 Rosebrook Way, Wareham, 02571, USA
| |
Collapse
|
35
|
Panez-Toro I, Heymann D, Gouin F, Amiaud J, Heymann MF, Córdova LA. Roles of inflammatory cell infiltrate in periprosthetic osteolysis. Front Immunol 2023; 14:1310262. [PMID: 38106424 PMCID: PMC10722268 DOI: 10.3389/fimmu.2023.1310262] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Accepted: 11/13/2023] [Indexed: 12/19/2023] Open
Abstract
Classically, particle-induced periprosthetic osteolysis at the implant-bone interface has explained the aseptic loosening of joint replacement. This response is preceded by triggering both the innate and acquired immune response with subsequent activation of osteoclasts, the bone-resorbing cells. Although particle-induced periprosthetic osteolysis has been considered a foreign body chronic inflammation mediated by myelomonocytic-derived cells, current reports describe wide heterogeneous inflammatory cells infiltrating the periprosthetic tissues. This review aims to discuss the role of those non-myelomonocytic cells in periprosthetic tissues exposed to wear particles by showing original data. Specifically, we discuss the role of T cells (CD3+, CD4+, and CD8+) and B cells (CD20+) coexisting with CD68+/TRAP- multinucleated giant cells associated with both polyethylene and metallic particles infiltrating retrieved periprosthetic membranes. This review contributes valuable insight to support the complex cell and molecular mechanisms behind the aseptic loosening theories of orthopedic implants.
Collapse
Affiliation(s)
- Isidora Panez-Toro
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, University of Chile, Independencia, Santiago, Chile
- Nantes Université, Centre National de Recherche Scientifique (CNRS), UMR6286, US2B, Nantes, France
- Institut de Cancérologie de l’Ouest, Tumor Heterogeneity and Precision Medicine Laboratory, Saint-Herblain, France
| | - Dominique Heymann
- Nantes Université, Centre National de Recherche Scientifique (CNRS), UMR6286, US2B, Nantes, France
- Institut de Cancérologie de l’Ouest, Tumor Heterogeneity and Precision Medicine Laboratory, Saint-Herblain, France
- Nantes Université, Laboratory of Histology and Embryology, Medical School, Nantes, France
- The University of Sheffield, Dept of Oncology and Metabolism, Sheffield, United Kingdom
| | - François Gouin
- Department of Surgical Oncology, Centre Léon Bérard, Lyon, France
| | - Jérôme Amiaud
- Nantes Université, Laboratory of Histology and Embryology, Medical School, Nantes, France
| | - Marie-Françoise Heymann
- Nantes Université, Centre National de Recherche Scientifique (CNRS), UMR6286, US2B, Nantes, France
- Institut de Cancérologie de l’Ouest, Tumor Heterogeneity and Precision Medicine Laboratory, Saint-Herblain, France
| | - Luis A. Córdova
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, University of Chile, Independencia, Santiago, Chile
- IMPACT, Center of Interventional Medicine for Precision and Advanced Cellular Therapy, Santiago, Chile
- Oral and Maxillofacial Surgery, Clínica MEDS, Santiago, Chile
| |
Collapse
|
36
|
Stroobant L, de Taeye T, Byttebier P, Van Onsem S, Jacobs E, Burssens A, Victor J. Condylar constrained and rotating hinged implants in revision knee arthroplasty show similar survivorship and clinical outcome: a systematic review and meta-analysis. Knee Surg Sports Traumatol Arthrosc 2023; 31:5365-5380. [PMID: 37747534 DOI: 10.1007/s00167-023-07572-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Accepted: 09/03/2023] [Indexed: 09/26/2023]
Abstract
PURPOSE In revision total knee arthroplasty (TKA) ligament instability and bone defects might require more constraint implants such as a condylar constrained knee (CCK) or rotating hinged knee (RHK). When both implants are suitable, the choice remains controversial. The purpose of this systematic review and meta-analysis was to compare the survivorship and clinical outcome between CCK and RHK in revision TKA. METHODS Systematic literature research was performed. Studies analysing the clinical outcome and/or survivorship of CCK and/or RHK in revision TKA were included. Clinical outcomes included the Knee Society Score, both clinical (KSCS) and functional (KSFS), range of motion (ROM) and reoperations. Survival was defined as the time free from removal or revision of the femoral and/or tibial component. RESULTS A total of 40 articles analysing 4.555 knees were included. Survival did not differ between RHK and CCK implants (p = 0.6058), with, respectively, 91.6% and 89.8% survival after 5 years. Postoperative KSCS and KSFS were, respectively, 79.2 (SD 10.7) and 61.1 (SD 21.8) for the CCK group. Similar scores were noted for the RHK group with a KSCS of 80.2 (SD 14.1) and KSFS of 58.5 (SD 17.3). Postoperative ROM was similar for CCK (105.3°, SD 17.1°) and RHK patients (104.1°, SD 16.9°). CONCLUSION This meta-analysis revealed that both survivorship and clinical outcome are similar for CCK and RHK patients for whom both designs are technically suitable and indicated. LEVEL OF EVIDENCE IV.
Collapse
Affiliation(s)
- Lenka Stroobant
- Department Orthopaedic Surgery, University Hospital Ghent, Ghent, Belgium.
| | - Thijmen de Taeye
- Department Orthopaedic Surgery, University Hospital Ghent, Ghent, Belgium
| | - Paul Byttebier
- Department Orthopaedic Surgery, ASZ Aalst, Aalst, Belgium
| | | | - Ewoud Jacobs
- Department of Rehabilitation Sciences, Ghent University Faculty of Medicine and Health Sciences, Ghent, Belgium
| | - Arne Burssens
- Department Orthopaedic Surgery, University Hospital Ghent, Ghent, Belgium
| | - Jan Victor
- Department Orthopaedic Surgery, University Hospital Ghent, Ghent, Belgium
| |
Collapse
|
37
|
Ramos MS, Pasqualini I, Surace PA, Molloy RM, Deren ME, Piuzzi NS. Arthrofibrosis After Total Knee Arthroplasty: A Critical Analysis Review. JBJS Rev 2023; 11:01874474-202312000-00001. [PMID: 38079496 DOI: 10.2106/jbjs.rvw.23.00140] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
» Arthrofibrosis after total knee arthroplasty (TKA) is the new formation of excessive scar tissue that results in limited ROM, pain, and functional deficits.» The diagnosis of arthrofibrosis is based on the patient's history, clinical examination, absence of alternative diagnoses from diagnostic testing, and operative findings. Imaging is helpful in ruling out specific causes of stiffness after TKA. A biopsy is not indicated, and no biomarkers of arthrofibrosis exist.» Arthrofibrosis pathophysiology is multifactorial and related to aberrant activation and proliferation of myofibroblasts that primarily deposit type I collagen in response to a proinflammatory environment. Transforming growth factor-beta signaling is the best established pathway involved in arthrofibrosis after TKA.» Management includes both nonoperative and operative modalities. Physical therapy is most used while revision arthroplasty is typically reserved as a last resort. Additional investigation into specific pathophysiologic mechanisms can better inform targeted therapeutics.
Collapse
Affiliation(s)
- Michael S Ramos
- Department of Orthopaedic Surgery, Orthopaedic and Rheumatologic Institute, Cleveland Clinic Foundation, Cleveland, Ohio
| | | | | | | | | | | |
Collapse
|
38
|
Humez M, Fröschen FS, Wirtz DC, Kühn KD. [The third-generation modern cementing technique in hip and knee arthroplasty]. ORTHOPADIE (HEIDELBERG, GERMANY) 2023; 52:968-980. [PMID: 37828239 DOI: 10.1007/s00132-023-04446-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 09/01/2023] [Indexed: 10/14/2023]
Abstract
BACKGROUND Implant loosening is the most common reason for revision surgery. OBJECTIVES Contribution of modern cementing technique to the long-term stability of an implant. METHODS Evaluation of the available evidence on modern cementing technique. RESULTS Modern cementing technique in hip arthroplasty is considered established and leads to better cementing results. In knee arthroplasty, there are also specific recommendations, including intensive cleaning of the bone bed, mixing of bone cement under vacuum and application of bone cement to the implant and the bone. CONCLUSIONS The use of modern cementing technique in hip and knee arthroplasty facilitates cementing, increases safety, and minimizes the risk of mechanical loosening.
Collapse
Affiliation(s)
- Martina Humez
- Heraeus Medical GmbH, Philipp-Reis-Str. 8/13, 61273, Wehrheim, Deutschland.
| | | | | | - Klaus-Dieter Kühn
- Heraeus Medical GmbH, Philipp-Reis-Str. 8/13, 61273, Wehrheim, Deutschland
- Department of Orthopaedics and Trauma, Medizinische Universität Graz, Graz, Österreich
| |
Collapse
|
39
|
Rivkin G, Kandel L, Perets I, Tsohar T, Nasrawy T, Liebergall M. Total knee arthroplasty using a computerized assisted stereotaxic navigation system with bluetooth communication in obese patients - A randomized controlled study. Comput Assist Surg (Abingdon) 2023; 28:2162970. [PMID: 36637291 DOI: 10.1080/24699322.2022.2162970] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023] Open
Abstract
Correct mechanical alignment (180° hip-knee-angle (HKA)) may be difficult to obtain on a consistent basis in obese patients. This is a randomized controlled study comparing the post-operative coronal alignment in obese patients between two surgical total knee arthroplasty (TKA) techniques - conventional and computer assisted navigation. The primary outcome was the post-operative HKA. A total of 60 patients were assigned to undergo conventional total knee arthroplasty (30 patients) or computerized assisted stereotaxic navigation system with Bluetooth communication surgery (30 patients). One patient from the study group was excluded due to malfunction of the navigation system. Good quality x-rays were available in 57 patients. There was no difference between the groups. Post-operative HKA was 2.8° and 2.9° in the study and control groups, respectively (p = 0.87). In obese patients undergoing TKA, computerized navigation had no impact on post-op HKA. Clincal Trial Registration Number: HMO 0092-13.
Collapse
Affiliation(s)
- Gurion Rivkin
- Department of Orthopedics, Hadassah Hebrew University Hospital, Jerusalem, Israel
| | - Leonid Kandel
- Department of Orthopedics, Hadassah Hebrew University Hospital, Jerusalem, Israel
| | - Itay Perets
- Department of Orthopedics, Hadassah Hebrew University Hospital, Jerusalem, Israel
| | - Tamir Tsohar
- Department of Physiotherapy and Rehabilitation, Hadassah Hebrew University Hospital, Jerusalem, Israel
| | - Tarek Nasrawy
- Department of Orthopedics, Hadassah Hebrew University Hospital, Jerusalem, Israel
| | - Meir Liebergall
- Department of Orthopedics, Hadassah Hebrew University Hospital, Jerusalem, Israel
| |
Collapse
|
40
|
Pearson ZC, Harris AB, Agarwal AR, Kreulen RT, Martin J, Ahiarakwe U, Golladay GJ, Thakkar SC. Higher revision rates in patients with preoperative contralateral pes planovalgus deformity following total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2023; 31:4920-4926. [PMID: 37596366 DOI: 10.1007/s00167-023-07520-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/14/2023] [Accepted: 07/23/2023] [Indexed: 08/20/2023]
Abstract
PURPOSE The purpose of this study was to compare the incidence of revision in those with pes planovalgus deformity to those without using a large national database. Given the reciprocal changes in lower extremity alignment associated with planovalgus foot deformity, it has been suggested that patients with this deformity has worse outcomes following total knee arthroplasty (TKA). METHODS A retrospective cohort analysis of patients undergoing elective TKA was conducted using the PearlDiver database. Patients were stratified into three cohorts: those without pes planovalgus, patients with ipsilateral or bilateral pes planovalgus relative to the TKA, and patients with contralateral pes planovalgus. Patients with prior foot reconstructive surgery were excluded. The cohorts were each matched to those without pes planovalgus. Bivariate analysis was performed comparing 90-day medical complications and 2- and 4-year revisions following TKA. An adjusted number needed to be exposed for one additional person to be harmed (NNEH) was calculated using the adjusted odds ratio (OR) and unexposed event rate. RESULTS Following matched analysis, those with contralateral pes planovalgus had similar odds (OR 3.41; 95% CI 0.93-12.54; p = n.s.) for aseptic revision within 2 years but significantly higher odds (OR 3.35; 95% CI 1.08-10.41; p = 0.03) within 4 years when compared to those without a pes planovalgus deformity. Within 4 years, there was no significant difference in the incidence of aseptic revision (p = n.s.) in patients with ipsilateral/bilateral pes planovalgus. No patients in any cohort underwent septic revision within 4 years of TKA. CONCLUSION This study found that patients with contralateral pes planovalgus deformity had higher odds of aseptic revision within 4 years following primary TKA in a national database, suggesting that the change in gait kinematics associated with this deformity could possibly be associated with increased revision rates. LEVEL OF EVIDENCE Level III.
Collapse
Affiliation(s)
- Zachary C Pearson
- Department of Orthopaedic Surgery, The Johns Hopkins University School of Medicine, 601 North Caroline Street, Baltimore, MD, 21287, USA.
| | - Andrew B Harris
- Department of Orthopaedic Surgery, The Johns Hopkins University School of Medicine, 601 North Caroline Street, Baltimore, MD, 21287, USA
| | - Amil R Agarwal
- Department of Orthopaedic Surgery, The Johns Hopkins University School of Medicine, 601 North Caroline Street, Baltimore, MD, 21287, USA
| | - R Timothy Kreulen
- Department of Orthopaedic Surgery, The Johns Hopkins University School of Medicine, 601 North Caroline Street, Baltimore, MD, 21287, USA
| | - Jalen Martin
- Department of Orthopaedic Surgery, Western Michigan University Homer Stryker MD School of Medicine, Kalamazoo, MI, USA
| | - Uzoma Ahiarakwe
- Department of Orthopaedic Surgery, The Johns Hopkins University School of Medicine, 601 North Caroline Street, Baltimore, MD, 21287, USA
| | - Gregory J Golladay
- Department of Orthopaedic Surgery, Virginia Commonwealth University School of Medicine, Richmond, VA, USA
| | - Savyasachi C Thakkar
- Department of Orthopaedic Surgery, The Johns Hopkins University School of Medicine, 601 North Caroline Street, Baltimore, MD, 21287, USA
| |
Collapse
|
41
|
Walker EA, Fox MG, Blankenbaker DG, French CN, Frick MA, Hanna TN, Jawetz ST, Onks C, Said N, Stensby JD, Beaman FD. ACR Appropriateness Criteria® Imaging After Total Knee Arthroplasty: 2023 Update. J Am Coll Radiol 2023; 20:S433-S454. [PMID: 38040463 DOI: 10.1016/j.jacr.2023.08.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2023] [Accepted: 08/22/2023] [Indexed: 12/03/2023]
Abstract
Total knee arthroplasty is the most commonly performed joint replacement procedure in the United States. This manuscript will discuss the recommended imaging modalities for six clinical variants; 1. follow-up of symptomatic or asymptomatic patients with a total knee arthroplasty. Initial imaging, 2. Suspected infection after total knee arthroplasty. Additional imaging following radiographs, 3. Pain after total knee arthroplasty. Infection excluded. Suspect aseptic loosening or osteolysis or instability. Additional imaging following radiographs, 4. Pain after total knee arthroplasty. Suspect periprosthetic or hardware fracture. Additional imaging following radiographs, 5. Pain after total knee arthroplasty. Measuring component rotation. Additional imaging following radiographs, and 6. Pain after total knee arthroplasty. Suspect periprosthetic soft-tissue abnormality unrelated to infection, including quadriceps or patellar tendinopathy. Additional imaging following radiographs. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.
Collapse
Affiliation(s)
- Eric A Walker
- Penn State Milton S. Hershey Medical Center, Hershey, Pennsylvania; Uniformed Services University of the Health Sciences, Bethesda, Maryland.
| | | | - Donna G Blankenbaker
- University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin
| | - Cristy N French
- Penn State Health Milton S. Hershey Medical Center, Hershey, Pennsylvania
| | | | - Tarek N Hanna
- Emory University, Atlanta, Georgia; Committee on Emergency Radiology-GSER
| | | | - Cayce Onks
- Penn State Health, Hershey, Pennsylvania, Primary care physician
| | - Nicholas Said
- Duke University Medical Center, Durham, North Carolina
| | | | | |
Collapse
|
42
|
Lee CR, Kim CW, Park DH, Kwon YU, Yoon JM. Risk of Infection After Septic and Aseptic Revision Total Knee Arthroplasty: A Systematic Review. J Bone Joint Surg Am 2023; 105:1630-1637. [PMID: 37616387 DOI: 10.2106/jbjs.23.00361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 08/26/2023]
Abstract
BACKGROUND The causes of primary total knee arthroplasty (TKA) failure can be divided into septic and aseptic etiologies. It is unclear whether the etiology affects the infection rate after revision TKA. This systematic review was conducted to evaluate whether there is a difference in infection rates between septic and aseptic revision TKA. We hypothesized that infection rates would be higher after septic revision TKA. METHODS The PubMed and Embase databases and the Cochrane Library were searched to find studies evaluating infection rates following septic and aseptic revision TKA. We included studies that compared the postoperative infection rates of a group that received revision TKA for aseptic failure and a group that received 1- or 2-stage revision TKA for septic failure. Studies on re-revision TKA and on revision surgery after partial knee arthroplasty were excluded, as were studies of debridement, antibiotics, and implant retention (DAIR). RESULTS Twelve studies were included in this systematic review. In studies in which 1- or 2-stage revision TKA was performed for septic failure, septic revision TKA had a significantly higher infection rate than aseptic revision TKA (odds ratio [OR], 6.83; 95% confidence interval [CI], 1.54 to 30.33; p = 0.01). Similarly, in studies in which 2-stage revision TKA was performed for septic failure, septic revision TKA had a significantly higher infection rate than aseptic revision TKA (OR, 4.14; 95% CI, 2.33 to 7.36; p < 0.00001). In the comparison of revision TKA for aseptic loosening and septic revision TKA, septic revision TKA had a higher infection rate than aseptic revision TKA (OR, 4.45; 95% CI, 2.28 to 8.70; p < 0.0001). CONCLUSIONS Overall, septic revision TKA had a higher infection rate than aseptic revision TKA. Even when 2-stage revision TKA was performed for septic failure, the infection rate was higher after septic revision TKA than after aseptic revision. Surgeons should explain the relatively high infection rates to patients undergoing revision TKA for septic failure of their primary joint replacement. LEVEL OF EVIDENCE Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Chang-Rack Lee
- Department of Orthopedic Surgery, Inje University Busan Paik Hospital, Busan, Republic of Korea
| | | | | | | | | |
Collapse
|
43
|
Dandois F, Taylan O, Müller JH, Scheys L. Sensitivity of Model-Based Predictions of Post-TKA Kinematic Behavior to Residual Errors in Ultrasound-Based Knee Collateral Ligament Strain Assessment. SENSORS (BASEL, SWITZERLAND) 2023; 23:8268. [PMID: 37837097 PMCID: PMC10574986 DOI: 10.3390/s23198268] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Revised: 09/25/2023] [Accepted: 09/30/2023] [Indexed: 10/15/2023]
Abstract
Ultrasound-based ligament strain estimation shows promise in non-invasively assessing knee joint collateral ligament behavior and improving ligament balancing procedures. However, the impact of ultrasound-based strain estimation residual errors on in-silico arthroplasty predictions remains unexplored. We investigated the sensitivity of post-arthroplasty kinematic predictions to ultrasound-based strain estimation errors compared to clinical inaccuracies in implant positioning.Two cadaveric legs were submitted to active squatting, and specimen-specific rigid computer models were formulated. Mechanical properties of the ligament model were optimized to reproduce experimentally obtained tibiofemoral kinematics and loads with minimal error. Resulting remaining errors were comparable to the current state-of-the-art. Ultrasound-derived strain residual errors were then introduced by perturbing lateral collateral ligament (LCL) and medial collateral ligament (MCL) stiffness. Afterwards, the implant position was perturbed to match with the current clinical inaccuracies reported in the literature. Finally, the impact on simulated post-arthroplasty tibiofemoral kinematics was compared for both perturbation scenarios. Ultrasound-based errors minimally affected kinematic outcomes (mean differences < 0.73° in rotations, 0.1 mm in translations). Greatest differences occurred in external tibial rotations (-0.61° to 0.73° for MCL, -0.28° to 0.27° for LCL). Comparatively, changes in implant position had larger effects, with mean differences up to 1.95° in external tibial rotation and 0.7 mm in mediolateral translation. In conclusion, our study demonstrated that the ultrasound-based assessment of collateral ligament strains has the potential to enhance current computer-based pre-operative knee arthroplasty planning.
Collapse
Affiliation(s)
- Félix Dandois
- Institute for Orthopaedic Research and Training (IORT), Development and Regeneration Department, KU Leuven, 49 Herestraat, 3000 Leuven, Belgium (O.T.)
| | - Orçun Taylan
- Institute for Orthopaedic Research and Training (IORT), Development and Regeneration Department, KU Leuven, 49 Herestraat, 3000 Leuven, Belgium (O.T.)
| | | | - Lennart Scheys
- Institute for Orthopaedic Research and Training (IORT), Development and Regeneration Department, KU Leuven, 49 Herestraat, 3000 Leuven, Belgium (O.T.)
- Department of Orthopaedics, University Hospitals Leuven, 49 Herestraat, 3000 Leuven, Belgium
| |
Collapse
|
44
|
Morel J, McNeilly O, Grundy S, Brown T, Gunawan C, Amal R, Scott JA. Nanoscale Titanium Surface Engineering via Low-Temperature Hydrothermal Etching for Enhanced Antimicrobial Properties. ACS APPLIED MATERIALS & INTERFACES 2023; 15:46247-46260. [PMID: 37738302 DOI: 10.1021/acsami.3c09525] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/24/2023]
Abstract
Bioinspired nanotopography artificially fabricated on titanium surfaces offers a solution for the rising issue of postoperative infections within orthopedics. On a small scale, hydrothermal etching has proven to deliver an effective antimicrobial nanospike surface. However, translation to an industrial setting is limited by the elevated synthesis temperature (150 °C) and associated equipment requirements. Here, for the first time, we fabricate surface nanostructures using comparatively milder synthesis temperatures (75 °C), which deliver physicochemical properties and antimicrobial capability comparable to the high-temperature surface. Using a KOH etchant, the simultaneous formation of titania and titanate crystals at both temperatures produces a one-dimensional nanostructure array. Analysis indicated that the formation mechanism comprises dissolution and reprecipitation processes, identifying the deposited titanates as hydrated layered tetra-titanates (K2Ti4O9·nH2O). A proposed nanospike formation mechanism was confirmed through the identification of a core and outer shell for individual nanostructures, primarily comprised of titanates and titania, respectively. Etching conditions dictated crystalline formation, favoring a thicker titanate core for nanorods under higher synthesis temperatures and etchant concentrations. A bactericidal investigation showed the efficacy against Gram-negative bacteria for a representative low-temperature nanosurface (34.4 ± 14.4%) was comparable to the higher temperature nanosurface (34.0 ± 17.0%), illustrating the potential of low-temperature hydrothermal synthesis. Our results provide valuable insight into the applicability of low-temperature etching protocols that are more favorable in large-scale manufacturing settings.
Collapse
Affiliation(s)
- James Morel
- School of Chemical Engineering, University of New South Wales, Kensington, NSW 2052, Australia
| | - Oliver McNeilly
- Australian Institute for Microbiology and Infection, University of Technology Sydney, Broadway, NSW 2007, Australia
| | - Sarah Grundy
- School of Chemical Engineering, University of New South Wales, Kensington, NSW 2052, Australia
| | - Toby Brown
- Corin Australia, Pymble, NSW 2073, Australia
| | - Cindy Gunawan
- Australian Institute for Microbiology and Infection, University of Technology Sydney, Broadway, NSW 2007, Australia
| | - Rose Amal
- School of Chemical Engineering, University of New South Wales, Kensington, NSW 2052, Australia
| | - Jason A Scott
- School of Chemical Engineering, University of New South Wales, Kensington, NSW 2052, Australia
| |
Collapse
|
45
|
Chalmers BP, Borsinger TM, Quevedo Gonzalez FJ, Vigdorchik JM, Haas SB, Ast MP. Referencing the center of the femoral head during robotic or computer-navigated primary total knee arthroplasty results in less femoral component flexion than the traditional intramedullary axis. Knee 2023; 44:172-179. [PMID: 37672908 DOI: 10.1016/j.knee.2023.08.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/14/2023] [Revised: 07/14/2023] [Accepted: 08/06/2023] [Indexed: 09/08/2023]
Abstract
BACKGROUND During robotic and computer-navigated primary total knee arthroplasty (TKA), the center of the femoral head is utilized as the proximal reference point for femoral component position rather than the intramedullary axis. We sought to analyze the effect on femoral component flexion-extension position between these two reference points. METHODS We obtained CT 3D-reconstructions of 50 cadaveric intact femurs. We defined the navigation axis as the line from center of the femoral head to center of the knee (lowest point of the trochlear groove) and the intramedullary axis as the line from center of the knee to center of the canal at the isthmus. Differences between these axes in the sagittal plane were measured. Degree of femoral bow and femoral neck anteversion were correlated with the differences between the two femoral axes. RESULTS On average, the navigated axis was 1.4° (range, -1.4° to 4.1°) posterior to the intramedullary axis. As such, the femoral component would have on average 1.4° less flexion compared with techniques referencing the intramedullary canal. A more anterior intramedullary compared with navigated axis (i.e., less femoral flexion) was associated with more femoral bow (R2 = 0.7, P < 0.001) and less femoral neck anteversion (R2 = 0.5, P < 0.05). CONCLUSION Computer-navigated or robotic TKA in which the center of the femoral head is utilized as a reference point, results in 1.4° less femoral component flexion than would be achieved by referencing the intramedullary canal. Surgeons should be aware of these differences as they may ultimately influence knee kinematics.
Collapse
Affiliation(s)
- Brian P Chalmers
- Department of Orthopedic Surgery, Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY, USA.
| | - Tracy M Borsinger
- Department of Orthopedic Surgery, Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY, USA
| | | | - Jonathan M Vigdorchik
- Department of Orthopedic Surgery, Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY, USA
| | - Steven B Haas
- Department of Orthopedic Surgery, Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY, USA
| | - Michael P Ast
- Department of Orthopedic Surgery, Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY, USA
| |
Collapse
|
46
|
Hannon CP, Salih R, Barrack RL, Nunley RM. Cementless Versus Cemented Total Knee Arthroplasty: Concise Midterm Results of a Prospective Randomized Controlled Trial. J Bone Joint Surg Am 2023; 105:1430-1434. [PMID: 37347823 DOI: 10.2106/jbjs.23.00161] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 06/24/2023]
Abstract
BACKGROUND We previously reported the 2-year results of a prospective randomized controlled trial of cementless versus cemented total knee arthroplasty (TKA) implants of the same design. The purpose of the present study was to provide concise results at intermediate-term follow-up. METHODS The original study included 141 TKAs (76 performed without cement and 65 performed with cement). Since then, 8 patients died and 4 withdrew. Of the remaining 129 patients, 127 (98%) were available for analysis. Survivorship analysis was performed; Oxford Knee, Knee Society, and Forgotten Joint Scores were calculated; and radiographs reviewed. Mean follow-up was 6 years. RESULTS The survivorship free of any revision was 100% in both groups. There were no differences between the groups in any patient-reported functional outcome measure (p = 0.2 to 0.5). However, a higher percentage of patients in the cementless TKA group were either extremely or very satisfied with their overall function (p = 0.01). Radiographically, there was no evidence of implant loosening in either group. CONCLUSIONS At 6 years, there were no differences between cementless and cemented TKA implants of the same design in terms of survivorship, clinical, or radiographic outcomes. LEVEL OF EVIDENCE Therapeutic Level I . See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Charles P Hannon
- Department of Orthopedic Surgery, Washington University in St. Louis, St. Louis, Missouri
| | | | | | | |
Collapse
|
47
|
Hampton M, Balachandar V, Charalambous CP, Sutton PM. Cementing Techniques In Knee Surgery (CeTIKS): a UK expert consensus study. Bone Jt Open 2023; 4:682-688. [PMID: 37669769 PMCID: PMC10480017 DOI: 10.1302/2633-1462.49.bjo-2023-0032.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 09/07/2023] Open
Abstract
Aims Aseptic loosening is the most common cause of failure following cemented total knee arthroplasty (TKA), and has been linked to poor cementation technique. We aimed to develop a consensus on the optimal technique for component cementation in TKA. Methods A UK-based, three-round, online modified Delphi Expert Consensus Study was completed focusing on cementation technique in TKA. Experts were identified as having a minimum of five years' consultant experience in the NHS and fulfilling any one of the following criteria: a 'high volume' knee arthroplasty practice (> 150 TKAs per annum) as identified from the National joint Registry of England, Wales, Northern Ireland and the Isle of Man; a senior author of at least five peer reviewed articles related to TKA in the previous five years; a surgeon who is named trainer for a post-certificate of comletion of training fellowship in TKA. Results In total, 81 experts (round 1) and 80 experts (round 2 and 3) completed the Delphi Study. Four domains with a total of 24 statements were identified. 100% consensus was reached within the cement preparation, pressurization, and cement curing domains. 90% consensus was reached within the cement application domain. Consensus was not reached with only one statement regarding the handling of cement during initial application to the tibial and/or femoral bone surfaces. Conclusion The Cementing Techniques In Knee Surgery (CeTIKS) Delphi consensus study presents comprehensive recommendations on the optimal technique for component cementing in TKA. Expert opinion has a place in the hierarchy of evidence and, until better evidence is available these recommendations should be considered when cementing a TKA.
Collapse
Affiliation(s)
- Matthew Hampton
- Northern General Hospital, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, UK
| | - Vivek Balachandar
- Northern General Hospital, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, UK
| | - Charalambos P. Charalambous
- Orthopaedic Department, Blackpool Victoria Hospital, Blackpool, UK
- School of Medicine, University of Central Lancashire, Preston, UK
| | - Paul M. Sutton
- Northern General Hospital, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, UK
| | - The CeTIKS study group
- Northern General Hospital, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, UK
- Orthopaedic Department, Blackpool Victoria Hospital, Blackpool, UK
- School of Medicine, University of Central Lancashire, Preston, UK
| |
Collapse
|
48
|
Salimy MS, Blackburn AZ, Katakam A, Bedair HS, Melnic CM. Utility of Diagnostic Markers in Late Periprosthetic Joint Infection Workup for Total Knee Arthroplasty Patients Who Received Antibiotics 48 Hours Before Aspiration. J Arthroplasty 2023; 38:1854-1860. [PMID: 36933676 DOI: 10.1016/j.arth.2023.03.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/10/2022] [Revised: 03/07/2023] [Accepted: 03/09/2023] [Indexed: 03/20/2023] Open
Abstract
BACKGROUND Diagnosing periprosthetic joint infection (PJI) following total knee arthroplasty (TKA) remains challenging despite recent advancements in testing and evolving criteria over the last decade. Moreover, the effects of antibiotic use on diagnostic markers are not fully understood. Thus, this study sought to determine the influence of antibiotic use within 48 hours before knee aspiration on synovial and serum laboratory values for suspected late PJI. METHODS Patients who underwent a TKA and subsequent knee arthrocentesis for PJI workup at least 6 weeks after their index arthroplasty were reviewed across a single healthcare system from 2013 to 2020. Median synovial white blood cell (WBC) count, synovial polymorphonuclear (PMN) percentage, serum erythrocyte sedimentation rate (ESR), serum C-reactive protein (CRP), and serum WBC count were compared between immediate antibiotic and nonantibiotic PJI groups. Receiver operating characteristic (ROC) curves and Youden's index were used to determine test performance and diagnostic cutoffs for the immediate antibiotics group. RESULTS The immediate antibiotics group had significantly more culture-negative PJIs than the no antibiotics group (38.1 versus 16.2%, P = .0124). Synovial WBC count demonstrated excellent discriminatory ability for late PJI in the immediate antibiotics group (area under curve, AUC = 0.97), followed by synovial PMN percentage (AUC = 0.88), serum CRP (AUC = 0.86), and serum ESR (AUC = 0.82). CONCLUSION Antibiotic use immediately preceding knee aspiration should not preclude the utility of synovial and serum lab values for the diagnosis of late PJI. Instead, these markers should be considered thoroughly during infection workup considering the high rate of culture-negative PJI in these patients. LEVEL OF EVIDENCE Level III, retrospective comparative study.
Collapse
Affiliation(s)
- Mehdi S Salimy
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts
| | - Amy Z Blackburn
- Department of Orthopaedic Surgery, Newton-Wellesley Hospital, Newton, Massachusetts
| | - Akhil Katakam
- Department of Orthopaedic Surgery, Newton-Wellesley Hospital, Newton, Massachusetts
| | - Hany S Bedair
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts; Department of Orthopaedic Surgery, Newton-Wellesley Hospital, Newton, Massachusetts
| | - Christopher M Melnic
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts; Department of Orthopaedic Surgery, Newton-Wellesley Hospital, Newton, Massachusetts
| |
Collapse
|
49
|
Awwad GEH, Ahedi H, Angadi D, Kandhari V, Coolican MRJ. A prospective randomised controlled trial of cemented and uncemented tibial baseplates: functional and radiological outcomes. Arch Orthop Trauma Surg 2023; 143:5891-5899. [PMID: 37000266 DOI: 10.1007/s00402-023-04831-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Accepted: 02/28/2023] [Indexed: 04/01/2023]
Abstract
INTRODUCTION With the success of uncemented fixation in younger patients undergoing total hip arthroplasty and the growing demand for total knee arthroplasty (TKA) in a younger cohort of patients, there has been an increasing interest in cementless tibial baseplate fixation. We sought to determine whether there was a clear advantage to the use of three different forms of tibial baseplate fixation. The primary outcome of this study was survivorship and secondary outcomes were functional and radiological outcomes, up until 10 years. MATERIALS AND METHODS We conducted a randomised controlled trial and recruited 224 patients with 274 knees. Patients underwent TKA by a single surgeon utilising a standard surgical technique. All patients received a cruciate retaining TKA with a cementless femoral component, and were randomised to receive either a cemented tibial component, a pegged porous coated cementless tibial component with screws or a cementless tantalum monoblock tibial component with pegs. Patient reported outcome measures (PROMS), radiological data and survivorship were assessed until 10 years post-operatively. RESULTS Pre-operative range of motion, alignment and PROMS were similar between the three groups. The use of cemented, cementless with screws or cementless with pegs fixation options, lead to differences in functional outcomes. There was greater improvement in the Oxford score and Knee Society Score in patients who received a cemented baseplate compared to tantalum and the pegged porous groups. However, radiological and survival outcomes were similar in all three groups. Overall survivorship was 99.6%, with one knee with cementless tibial fixation and screws revised for subsidence at 3 years. There were no cases of venous thromboembolism, periprosthetic fracture or infection. CONCLUSIONS Irrespective of tibial fixation method, functional and radiological outcomes remain similar at follow-up at 10 years, with no clear difference in outcome between each group. Each method of fixation also had excellent survivorship over this period and should reassure surgeons that whichever method of fixation they choose, long-term outcomes are likely to be satisfactory.
Collapse
Affiliation(s)
- George E H Awwad
- Sydney Orthopaedic Research Institute, Sydney, Australia.
- Flinders Medical Centre, Adelaide, Australia.
| | - H Ahedi
- Sydney Orthopaedic Research Institute, Sydney, Australia
- University of Tasmania, Tasmania, Australia
| | - D Angadi
- Sydney Orthopaedic Research Institute, Sydney, Australia
| | - V Kandhari
- Sydney Orthopaedic Research Institute, Sydney, Australia
| | - M R J Coolican
- Sydney Orthopaedic Research Institute, Sydney, Australia
- Royal Northshore Hospital, Sydney, Australia
| |
Collapse
|
50
|
Flury A, Hoch A, Cirigliano G, Hodel S, Kühne N, Zimmermann SM, Vlachopoulos L, Fucentese SF. Excessive femoral torsion is not associated with patellofemoral pain or instability if TKA is functionally aligned and the patella denervated. Knee Surg Sports Traumatol Arthrosc 2023; 31:3665-3671. [PMID: 36114342 PMCID: PMC10435632 DOI: 10.1007/s00167-022-07162-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/24/2022] [Accepted: 09/05/2022] [Indexed: 10/14/2022]
Abstract
PURPOSE Recent data suggest that individual morphologic factors should be respected to restore preoperative patellofemoral alignment and thus reduce the likelihood of anterior knee pain. The goal of this study was to investigate the effect of excessive femoral torsion (FT) on clinical outcome of TKA. METHODS Patients who underwent TKA and complete preoperative radiographic evaluation including a long-leg radiograph and CT scan were included. 51 patients showed increased FT of > 20° and were matched for age/sex to 51 controls (FT < 20°). Thirteen patients were lost to follow-up. Thirty-eight matched pairs were compared after a 2 year follow-up clinically (Kujala and patellofemoral score for TKA) and radiographically (FT, frontal leg axis, TT-TG, patellar thickness, patellar tilt, and lateral displacement of patella). Functional alignment of TKA was performed (hybrid-technique). All patellae were denervated but no patella was resurfaced. RESULTS There was no significant difference between clinical scores two years after surgery between patients with normal and excessive FT (n.s.). Kujala score was 64.3 ± 16.7 versus 64.8 ± 14.4 (n.s.), and patellofemoral score for TKA was 74.3 ± 21 versus 78.5 ± 20.7 (n.s.) for increased FT group and control group, respectively. There was no correlation between preoperative FT and clinical scores. Other radiographic parameters were similar between both groups. No correlations between clinical outcomes and preoperative/postoperative frontal leg axis or total leg axis correction were found (n.s.). CONCLUSION If the leg axis deformity is corrected to a roughly neutral alignment during cemented TKA, including patellar denervation, then excessive FT was not associated with patellofemoral pain or instability. LEVEL OF EVIDENCE Prospective comparative study, level II.
Collapse
Affiliation(s)
- Andreas Flury
- Orthopaedic Department, Balgrist University Hospital, University of Zurich, Forchstrasse 340, CH-8008, Zurich, Switzerland.
| | - Armando Hoch
- Orthopaedic Department, Balgrist University Hospital, University of Zurich, Forchstrasse 340, CH-8008, Zurich, Switzerland
| | - Gabriele Cirigliano
- Orthopaedic Department, Balgrist University Hospital, University of Zurich, Forchstrasse 340, CH-8008, Zurich, Switzerland
| | - Sandro Hodel
- Orthopaedic Department, Balgrist University Hospital, University of Zurich, Forchstrasse 340, CH-8008, Zurich, Switzerland
| | - Nathalie Kühne
- Orthopaedic Department, Balgrist University Hospital, University of Zurich, Forchstrasse 340, CH-8008, Zurich, Switzerland
| | - Stefan M Zimmermann
- Orthopaedic Department, Balgrist University Hospital, University of Zurich, Forchstrasse 340, CH-8008, Zurich, Switzerland
| | - Lazaros Vlachopoulos
- Orthopaedic Department, Balgrist University Hospital, University of Zurich, Forchstrasse 340, CH-8008, Zurich, Switzerland
| | - Sandro F Fucentese
- Orthopaedic Department, Balgrist University Hospital, University of Zurich, Forchstrasse 340, CH-8008, Zurich, Switzerland
| |
Collapse
|