Sass JO, Kebbach M, Lork C, Johannsen J, Weinmann M, Stenzel M, Bader R. Computational biomechanical study on hybrid implant materials for the femoral component of total knee replacements. J Mech Behav Biomed Mater 2024; 158:106681. [PMID: 39151255 DOI: 10.1016/j.jmbbm.2024.106681] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2024] [Revised: 06/15/2024] [Accepted: 08/08/2024] [Indexed: 08/19/2024]
Abstract
Multifunctional materials have been described to meet the diverse requirements of implant materials for femoral components of uncemented total knee replacements. These materials aim to combine the high wear and corrosion resistance of oxide ceramics at the joint surfaces with the osteogenic potential of titanium alloys at the bone-implant interface. Our objective was to evaluate the biomechanical performance of hybrid material-based femoral components regarding mechanical stress within the implant during cementless implantation and stress shielding (evaluated by strain energy density) of the periprosthetic bone during two-legged squat motion using finite element modeling. The hybrid materials consisted of alumina-toughened zirconia (ATZ) ceramic joined with additively manufactured Ti-6Al-4V or Ti-35Nb-6Ta alloys. The titanium component was modeled with or without an open porous surface structure. Monolithic femoral components of ATZ ceramic or Co-28Cr-6Mo alloy were used as reference. The elasticity of the open porous surface structure was determined within experimental compression tests and was significantly higher for Ti-35Nb-6Ta compared to Ti-6Al-4V (5.2 ± 0.2 GPa vs. 8.8 ± 0.8 GPa, p < 0.001). During implantation, the maximum stress within the ATZ femoral component decreased from 1568.9 MPa (monolithic ATZ) to 367.6 MPa (Ti-6Al-4V/ATZ), 560.9 MPa (Ti-6Al-4V/ATZ with an open porous surface), 474.9 MPa (Ti-35Nb-6Ta/ATZ), and 648.4 MPa (Ti-35Nb-6Ta/ATZ with an open porous surface). The strain energy density increased at higher flexion angles for all models during the squat movement. At ∼90° knee flexion, the strain energy density in the anterior region of the distal femur increased by 25.7 % (Ti-6Al-4V/ATZ), 70.3 % (Ti-6Al-4V/ATZ with an open porous surface), 43.7 % (Ti-35Nb-6Ta/ATZ), and 82.5% (Ti-35Nb-6Ta/ATZ with an open porous surface) compared to monolithic ATZ. Thus, the hybrid material-based femoral component decreases the intraoperative fracture risk of the ATZ part and considerably reduces the risk of stress shielding of the periprosthetic bone.
Collapse
Affiliation(s)
- Jan-Oliver Sass
- Research Laboratory for Biomechanics and Implant Technology, Department of Orthopedics, Rostock University Medical Center, Doberaner Straße 142, D-18057 Rostock, Germany.
| | - Maeruan Kebbach
- Research Laboratory for Biomechanics and Implant Technology, Department of Orthopedics, Rostock University Medical Center, Doberaner Straße 142, D-18057 Rostock, Germany
| | - Cornelia Lork
- ZM Praezisionsdentaltechnik GmbH, Breite Straße 16, D-18055 Rostock, Germany
| | - Jan Johannsen
- Fraunhofer Research Institution for Additive Manufacturing Technologies IAPT, Am Schleusengraben 14, D-21029 Hamburg, Germany
| | | | | | - Rainer Bader
- Research Laboratory for Biomechanics and Implant Technology, Department of Orthopedics, Rostock University Medical Center, Doberaner Straße 142, D-18057 Rostock, Germany
| |
Collapse
|
2
|
Polizzotti G, Lamberti A, Mancino F, Baldini A. New Horizons of Cementless Total Knee Arthroplasty. J Clin Med 2023; 13:233. [PMID: 38202240 PMCID: PMC10780266 DOI: 10.3390/jcm13010233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Revised: 12/09/2023] [Accepted: 12/10/2023] [Indexed: 01/12/2024] Open
Abstract
BACKGROUND Considering the increasing number of young and active patients needing TKA, orthopedic surgeons are looking for a long-lasting and physiological bond for the prosthetic implant. Multiple advantages have been associated with cementless fixation including higher preservation of the native bone stock, avoidance of cement debris with subsequent potential third-body wear, and the achievement of a natural bond and osseointegration between the implant and the bone that will provide a durable and stable fixation. DISCUSSION Innovations in technology and design have helped modern cementless TKA implants to improve dramatically. Better coefficient of friction and reduced Young's modulus mismatch between the implant and host bone have been related to the use of porous metal surfaces. Moreover, biologically active coatings have been used on modern implants such as periapatite and hydroxyapatite. These factors have increased the potential for ingrowth by reducing micromotion and increasing osteoconductive properties. New materials with better biocompatibility, porosity, and roughness have been introduced to increase implant stability. CONCLUSIONS Innovations in technology and design have helped modern cementless TKA implants improve primary stability in both the femur and tibia. This means that short-term follow-up are comparable to cemented. These positive prognostic factors may lead to a future in which cementless fixation may be considered the gold-standard technique in young and active patients.
Collapse
Affiliation(s)
- Giuseppe Polizzotti
- Istituto Chirurgico Ortopedico Traumatologico (ICOT), Sapienza University of Rome, 00185 Rome, Italy
| | | | - Fabio Mancino
- University College London Hospital, London NW1 2BU, UK
- The Princess Grace Hospital, London W1U 5NY, UK
| | - Andrea Baldini
- Istituto Fiorentino di Cura e Assistenza, 50139 Florence, Italy
| |
Collapse
|
3
|
Ruhr M, Huber G, Niki Y, Lohner L, Ondruschka B, Morlock MM. Impaction procedure influences primary stability of acetabular press-fit components. Bone Joint J 2023; 105-B:261-268. [PMID: 36854327 DOI: 10.1302/0301-620x.105b3.bjj-2022-1011.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/02/2023]
Abstract
The aim of the study was to investigate whether the primary stability of press-fit acetabular components can be improved by altering the impaction procedure. Three impaction procedures were used to implant acetabular components into human cadaveric acetabula using a powered impaction device. An impaction frequency of 1 Hz until complete component seating served as reference. Overimpaction was simulated by adding ten strokes after complete component seating. High-frequency implantation was performed at 6 Hz. The lever-out moment of the acetabular components was used as measure for primary stability. Permanent bone deformation was assessed by comparison of double micro-CT (µCT) measurements before and after impaction. Acetabular component deformation and impaction forces were recorded, and the extent of bone-implant contact was determined from 3D laser scans. Overimpaction reduced primary acetabular component stability (p = 0.038) but did not significantly increase strain release after implantation (p = 0.117) or plastic deformations (p = 0.193). Higher press-fits were associated with larger polar gaps for the 1 Hz reference impaction (p = 0.002, R2 = 0.77), with a similar trend for overimpaction (p = 0.082, R2 = 0.31). High-frequency impaction did not significantly increase primary stability (p = 0.170) at lower impaction forces (p = 0.001); it was associated with smaller plastic deformations (p = 0.035, R2 = 0.34) and a trend for increased acetabular component relaxation between strokes (p = 0.112). Higher press-fit was not related to larger polar gaps for the 6 Hz impaction (p = 0.346). Overimpaction of press-fit acetabular components should be prevented since additional strokes can be associated with increased bone damage and reduced primary stability as shown in this study. High-frequency impaction at 6 Hz was shown to be beneficial compared with 1 Hz impaction. This benefit has to be confirmed in clinical studies.
Collapse
Affiliation(s)
- Miriam Ruhr
- Institute of Biomechanics, Hamburg University of Technology, Hamburg, Germany
| | - Gerd Huber
- Institute of Biomechanics, Hamburg University of Technology, Hamburg, Germany
| | - Yasaman Niki
- Institute of Biomechanics, Hamburg University of Technology, Hamburg, Germany
| | - Larissa Lohner
- Institute of Legal Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Benjamin Ondruschka
- Institute of Legal Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Michael M Morlock
- Institute of Biomechanics, Hamburg University of Technology, Hamburg, Germany
| |
Collapse
|
4
|
Clinical Application and Biological Functionalization of Different Surface Coatings in Artificial Joint Prosthesis: A Comprehensive Research Review. COATINGS 2022. [DOI: 10.3390/coatings12020117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
With advances in materials science and biology, there have been continuing innovations in the field of artificial joint prostheses. Cementless prostheses have the advantages of long service life, easy revision, and good initial stability and are widely used in artificial joint replacement. Coatings are the key to cementless prostheses and are at the heart of their excellent functionality. This article mainly studies the clinical application of hydroxyapatite (HA) coating, standard porous coating represented by Porocoat coating, and new high-porosity coating represented by Gription coating. The clinical application and biological functionalization of different artificial joint prosthesis surface coatings are clarified, and it provides a reference for the clinical selection and development of different prosthesis surface coating materials.
Collapse
|
5
|
Anijs T, Wolfson D, Mercer A, Rock M, Verdonschot N, Janssen D. Experimental measurements of femoral primary stability in two cementless posterior-stabilized knee replacement implants. Med Eng Phys 2022; 99:103734. [DOI: 10.1016/j.medengphy.2021.103734] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Revised: 11/26/2021] [Accepted: 12/01/2021] [Indexed: 11/16/2022]
|
6
|
Sánchez E, Schilling C, Grupp TM, Giurea A, Verdonschot N, Janssen D. No effect in primary stability after increasing interference fit in cementless TKA tibial components. J Mech Behav Biomed Mater 2021; 118:104435. [PMID: 33721771 DOI: 10.1016/j.jmbbm.2021.104435] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2020] [Revised: 02/15/2021] [Accepted: 02/26/2021] [Indexed: 11/25/2022]
Abstract
Cementless total knee arthroplasty (TKA) implants rely on interference fit to achieve initial stability. However, the optimal interference fit is unknown. This study investigates the effect of using different interference fit on the initial stability of tibial TKA implants. Experiments were performed on human cadaveric tibias using a low interference fit of 350 μm of a clinically established cementless porous-coated tibial implant and a high interference fit of 700 μm. The Orthoload peak loads of gait and squat were applied to the specimens with a custom-made load applicator. Micromotions and gaps opening/closing were measured at the bone-implant interface using Digital Image Correlation (DIC) in 6 regions of interest (ROIs). Two multilevel linear mixed-effect models were created with micromotions and gaps as dependent variables. The results revealed no significant differences for micromotions between the two interference fits (gait p = 0.755, squat p = 0.232), nor for gaps opening/closing (gait p = 0.474, squat p = 0.269). In contrast, significant differences were found for the ROIs in the two dependent variables (p < 0.001), where more gap closing was seen in the posterior ROIs than in the anterior ROIs during both loading configurations. This study showed that increasing the interference fit from 350 to 700 μm did not influence initial stability.
Collapse
Affiliation(s)
- Esther Sánchez
- Radboud University Medical Center, Radboud Institute for Health Sciences, Orthopaedic Research Lab, Nijmegen, the Netherlands.
| | | | - Thomas M Grupp
- Aesculap AG, Research & Development, Tuttlingen, Germany; Ludwig Maximilians University Munich, Department of Orthopaedic Surgery, Physical Medicine & Rehabilitation, Campus Grosshadern, Munich, Germany
| | - Alexander Giurea
- Medical University of Vienna, Department of Orthopedics, Vienna, Austria
| | - Nico Verdonschot
- Radboud University Medical Center, Radboud Institute for Health Sciences, Orthopaedic Research Lab, Nijmegen, the Netherlands; University of Twente, Laboratory for Biomechanical Engineering, Faculty of Engineering Technology, Enschede, the Netherlands
| | - Dennis Janssen
- Radboud University Medical Center, Radboud Institute for Health Sciences, Orthopaedic Research Lab, Nijmegen, the Netherlands
| |
Collapse
|
7
|
Bingham JS, Salib CG, Hanssen AD, Taunton MJ, Pagnano MW, Abdel MP. Clinical Outcomes and Survivorship of Contemporary Cementless Primary Total Knee Arthroplasties. JBJS Rev 2020; 8:e2000026. [PMID: 32960025 DOI: 10.2106/jbjs.rvw.20.00026] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
BACKGROUND Total knee arthroplasties (TKAs) with cementless fixation have been studied in multiple series with varying success. The aim of this study was to prepare a systematic review of the literature to evaluate clinical outcomes and revtpdelision rates of patients undergoing contemporary cementless TKA. METHODS A search of PubMed and MEDLINE was conducted for English-language articles published between 2005 and 2018 to identify studies examining survivorship and clinical outcomes of cementless TKAs. Studies that reported clinical and/or radiographic outcomes were included. Data collected included the number of TKAs, implant utilized, primary diagnosis, mean age and follow-up, implant survivorship, complications, revisions, and clinical outcome scores. All hybrid constructs and revision TKAs were excluded. Poisson regression analysis was used to determine the revision incidence rates per 1,000 person-years. RESULTS Forty-three studies with 10,447 TKAs met inclusion criteria, of which 8,187 were primary cementless TKAs. The mean follow-up was 7 years. The revision incidence per 1,000 person-years was 4.8 for all cementless designs. The complication rate for all cementless TKAs was 6%, with deep venous thrombosis being the most common complication. The mean postoperative Knee Society Score and Functional Score were 92 and 83, respectively. CONCLUSIONS While newer-generation cementless designs have shown improved survivorship and clinical outcomes compared with earlier-generation cementless designs, the literature for cementless designs remains limited when compared with cemented designs. Further studies are needed to determine if cementless TKA can achieve the same benefits that have been realized with cementless total hip arthroplasty. LEVEL OF EVIDENCE Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Joshua S Bingham
- 1Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota 2Department of Orthopedic Surgery, Mayo Clinic, Phoenix, Arizona
| | | | | | | | | | | |
Collapse
|
8
|
Gao X, Fraulob M, Haïat G. Biomechanical behaviours of the bone-implant interface: a review. J R Soc Interface 2019; 16:20190259. [PMID: 31362615 PMCID: PMC6685012 DOI: 10.1098/rsif.2019.0259] [Citation(s) in RCA: 109] [Impact Index Per Article: 18.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2019] [Accepted: 07/01/2019] [Indexed: 01/09/2023] Open
Abstract
In recent decades, cementless implants have been widely used in clinical practice to replace missing organs, to replace damaged or missing bone tissue or to restore joint functionality. However, there remain risks of failure which may have dramatic consequences. The success of an implant depends on its stability, which is determined by the biomechanical properties of the bone-implant interface (BII). The aim of this review article is to provide more insight on the current state of the art concerning the evolution of the biomechanical properties of the BII as a function of the implant's environment. The main characteristics of the BII and the determinants of implant stability are first introduced. Then, the different mechanical methods that have been employed to derive the macroscopic properties of the BII will be described. The experimental multi-modality approaches used to determine the microscopic biomechanical properties of periprosthetic newly formed bone tissue are also reviewed. Eventually, the influence of the implant's properties, in terms of both surface properties and biomaterials, is investigated. A better understanding of the phenomena occurring at the BII will lead to (i) medical devices that help surgeons to determine an implant's stability and (ii) an improvement in the quality of implants.
Collapse
Affiliation(s)
- Xing Gao
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, UMR CNRS 8208, 61 avenue du Général de Gaulle, 94010 Créteil cedex, France
- Research Centre for Medical Robotics and Minimally Invasive Surgical Devices, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, People's Republic of China
| | - Manon Fraulob
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, UMR CNRS 8208, 61 avenue du Général de Gaulle, 94010 Créteil cedex, France
| | - Guillaume Haïat
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, UMR CNRS 8208, 61 avenue du Général de Gaulle, 94010 Créteil cedex, France
| |
Collapse
|
9
|
Berahmani S, Hendriks M, de Jong JJA, van den Bergh JPW, Maal T, Janssen D, Verdonschot N. Evaluation of interference fit and bone damage of an uncemented femoral knee implant. Clin Biomech (Bristol, Avon) 2018; 51:1-9. [PMID: 29132027 DOI: 10.1016/j.clinbiomech.2017.10.022] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/04/2016] [Revised: 10/25/2017] [Accepted: 10/30/2017] [Indexed: 02/07/2023]
Abstract
BACKGROUND During implantation of an uncemented femoral knee implant, press-fit interference fit provides the primary stability. It is assumed that during implantation a combination of elastic and plastic deformation and abrasion of the bone will occur, but little is known about what happens at the bone-implant interface and how much press-fit interference fit is eventually achieved. METHODS Five cadaveric femora were prepared and implantation was performed by an experienced surgeon. Micro-CT- and conventional CT-scans were obtained pre- and post-implantation for geometrical measurements and to measure bone mineral density. Additionally, the position of the implant with respect to the bone was determined by optical scanning of the reconstructions. By measuring the differences in surface geometry, assessments were made of the cutting error, the actual interference fit, the amount of bone damage, and the effective interference fit. FINDINGS Our analysis showed an average cutting error of 0.67mm (SD 0.17mm), which pointed mostly towards bone under-resections. We found an average actual AP interference fit of 1.48mm (SD 0.27mm), which was close to the nominal value of 1.5mm. INTERPRETATION We observed combinations of bone damage and elastic deformation in all bone specimens, which showed a trend to be related with bone density. Higher bone density tended to lead to lower bone damage and higher elastic deformation. The results of the current study indicate different factors that interact while implanting an uncemented femoral knee component. This knowledge can be used to fine-tune design criteria of femoral components to achieve adequate primary stability for all patients.
Collapse
Affiliation(s)
- Sanaz Berahmani
- Radboud university medical center, Radboud Institute for Health Sciences, Orthopaedic Research Lab, P.O. Box 9101, 6500 HB Nijmegen, The Netherlands.
| | - Maartje Hendriks
- Radboud university medical center, Radboud Institute for Health Sciences, Orthopaedic Research Lab, P.O. Box 9101, 6500 HB Nijmegen, The Netherlands
| | - Joost J A de Jong
- NUTRIM School for Nutrition and Translational Research in Metabolism, Maastricht University Medical Center, Maastricht, The Netherlands; Department of Rheumatology, Maastricht University Medical Center, Maastricht, The Netherlands
| | - Joop P W van den Bergh
- NUTRIM School for Nutrition and Translational Research in Metabolism, Maastricht University Medical Center, Maastricht, The Netherlands; Department of Rheumatology, Maastricht University Medical Center, Maastricht, The Netherlands; Department of Internal Medicine, VieCuri Medical Center, Venlo, The Netherlands; Faculty of Medicine and Life Sciences, Hasselt University, Hasselt, Belgium
| | - Thomas Maal
- Radboud university medical center, Department of Oral and Maxillofacial Surgery, Nijmegen, The Netherlands
| | - Dennis Janssen
- Radboud university medical center, Radboud Institute for Health Sciences, Orthopaedic Research Lab, P.O. Box 9101, 6500 HB Nijmegen, The Netherlands
| | - Nico Verdonschot
- Radboud university medical center, Radboud Institute for Health Sciences, Orthopaedic Research Lab, P.O. Box 9101, 6500 HB Nijmegen, The Netherlands; Laboratory for Biomechanical Engineering, University of Twente, Enschede, The Netherlands
| |
Collapse
|
10
|
Prudhon JL, Verdier R. Cemented or cementless total knee arthroplasty? - Comparative results of 200 cases at a minimum follow-up of 11 years. SICOT J 2017; 3:70. [PMID: 29232186 PMCID: PMC5726856 DOI: 10.1051/sicotj/2017046] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/14/2017] [Accepted: 08/21/2017] [Indexed: 11/14/2022] Open
Abstract
INTRODUCTION Since 1996 we have been using cementless fixation with hydroxyapatite (HA) coating. The purpose of this paper is to compare survivorship of a series of 100 cemented Total Knee Arthroplasty (TKA) to a similar series of 100 cementless with a follow up of 11-16 years. Material methods: Both TKA are mobile bearing total knee postero-stabilized. They can be used with cement or without cement. Among 1030 New Wave TKATM implanted from 2002 to 2015 we have identified 100 cemented TKAs and 100 cementless TKAs. All these cases were primary replacement. Differences in survival probability were determined using log-rank test. RESULTS Survival probabilities at 11 years of follow-up were: Cemented group: 90.2% CI95% [81.9-94.8]; Cementless group: 95.4% CI95% [88.1-98.2]. Comparison between both group showed significant difference, p = 0.32. DISCUSSION The advantages of cementless TKA are bone stock preservation, cement debris protection and the potential to achieve biologic fixation. Cementless implants rely on a porous or roughened surface to facilitate bone formation. HA has been shown to accelerate bone integration and to decrease micro motion of the components and to increase fixation. With a survival probability of 90.2% (cemented version) and 95.4% (cementless version), this total knee prosthesis performs as intended in primary total knee arthroplasty. No statistical differences could be found between cemented and cementless implants.
Collapse
Affiliation(s)
| | - Régis Verdier
- Groupe Lépine, 175 rue Jacquard, CS 50307, 69727 Genay Cedex, France
| |
Collapse
|
11
|
Experimental pre-clinical assessment of the primary stability of two cementless femoral knee components. J Mech Behav Biomed Mater 2017; 75:322-329. [DOI: 10.1016/j.jmbbm.2017.07.043] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2016] [Revised: 05/27/2016] [Accepted: 07/26/2017] [Indexed: 11/16/2022]
|
12
|
de Ruiter L, Janssen D, Briscoe A, Verdonschot N. Fixation strength of a polyetheretherketone femoral component in total knee arthroplasty. Med Eng Phys 2017; 49:157-162. [DOI: 10.1016/j.medengphy.2017.06.039] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2016] [Revised: 06/22/2017] [Accepted: 06/25/2017] [Indexed: 11/27/2022]
|
13
|
Experimental and computational analysis of micromotions of an uncemented femoral knee implant using elastic and plastic bone material models. J Biomech 2017; 61:137-143. [DOI: 10.1016/j.jbiomech.2017.07.023] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2016] [Revised: 07/05/2017] [Accepted: 07/16/2017] [Indexed: 11/22/2022]
|
14
|
Abstract
As the number of younger and more active patients treated with total knee arthroplasty (TKA) continues to increase, consideration of better fixation as a means of improving implant longevity is required. Cemented TKA remains the reference standard with the largest body of evidence and the longest follow-up to support its use. However, cementless TKA, may offer the opportunity of a more bone-sparing procedure with long lasting biological fixation to the bone. We undertook a review of the literature examining advances of cementless TKA and the reported results. Cite this article: Bone Joint J 2016;98-B:867–73.
Collapse
Affiliation(s)
- D. F. Dalury
- University of Maryland St. Joseph Medical
Center, Towson Orthopaedic Associates, Ruxton
Professional Center, 8322 Bellona Avenue, Suite
100, Towson, MD, 21204, USA
| |
Collapse
|
15
|
Berahmani S, Janssen D, Wolfson D, de Waal Malefijt M, Fitzpatrick CK, Rullkoetter PJ, Verdonschot N. FE analysis of the effects of simplifications in experimental testing on micromotions of uncemented femoral knee implants. J Orthop Res 2016; 34:812-9. [PMID: 26488795 DOI: 10.1002/jor.23074] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/02/2015] [Accepted: 10/16/2015] [Indexed: 02/04/2023]
Abstract
Experimental testing of orthopaedic implants requires simplifications concerning load application and activities being analyzed. This computational study investigated how these simplifications affect micromotions at the bone-implant interface of an uncemented femoral knee implant. As a basis, validated in vivo loads of the stance phase of gait and a deep knee bend were adopted. Eventually, three configurations were considered: (i) simulation of the complete loading cycle; (ii) inclusion of only tibiofemoral loads (ignoring patellofemoral loads); and (iii) applying only a single peak tibiofemoral force. For all loading conditions the largest micromotions found at the proximal anterior flange. Without the patellofemoral force, peak micromotions increased 6% and 22% for gait and deep knee bend, respectively. By applying a single peak tibiofemoral force micromotions were overestimated. However, the peak micromotions corresponded to the maximum tibiofemoral force, and strong micromotion correlations were found between a complete loading cycle and a single peak load (R(2) = 0.73 and R(2) = 0.89 for gait and deep knee bend, respectively). Deep knee bend resulted in larger micromotions than gait. Our study suggests that a simplified peak force can be used to assess the stability of cementless femoral components. For more robust testing, implants should be subjected to different loading modes. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:812-819, 2016.
Collapse
Affiliation(s)
- Sanaz Berahmani
- Orthopaedic Research Laboratory, Radboud Institute for Health Sciences, Radboud University Medical Center, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands
| | - Dennis Janssen
- Orthopaedic Research Laboratory, Radboud Institute for Health Sciences, Radboud University Medical Center, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands
| | - David Wolfson
- DePuy Synthes Joint Reconstruction, LS11 0BG, Leeds, United Kingdom
| | - Maarten de Waal Malefijt
- Department of Orthopaedics, Radboud Institute for Health Sciences, Radboud University Medical Center, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands
| | - Clare K Fitzpatrick
- Center for Orthopaedic Biomechanics, University of Denver, 2390 S. York St., Denver, 80208, Colorado
| | - Paul J Rullkoetter
- Center for Orthopaedic Biomechanics, University of Denver, 2390 S. York St., Denver, 80208, Colorado
| | - Nico Verdonschot
- Orthopaedic Research Laboratory, Radboud Institute for Health Sciences, Radboud University Medical Center, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands.,Laboratory of Biomechanical Engineering, University of Twente, Enschede, The Netherlands
| |
Collapse
|