Fey B, Brenneis M, Stief F, van Drongelen S. Effect of Stem Design and Positioning on the Leg Axis after Total Hip Arthroplasty: A Secondary Analysis. J Clin Med 2024; 13:4453. [PMID: 39124720 PMCID: PMC11313081 DOI: 10.3390/jcm13154453] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2024] [Revised: 07/10/2024] [Accepted: 07/25/2024] [Indexed: 08/12/2024] Open
Abstract
Background/Objectives: Various parameters, like femoral offset and leg length, are associated with good patient outcomes after total hip arthroplasty. In this prospective study, the effects of stem design, its placement in the proximal femur and the resulting femoral offset on the total leg axis were investigated. Methods: The 27 patients included in this study received biplanar radiography (EOS®, EOS Imaging) with 3D reconstruction using sterEOS® both preoperatively and postoperatively. For all leg alignment parameters obtained from the 3D reconstruction and from measurements using mediCAD, the deltas between the postoperative and preoperative values were determined. Patients were divided into those who received a short-stem prosthesis and those who received a straight-stem prosthesis. Results: The change in femoral offset with the implantation of a short-stem prosthesis was significantly greater than that with the implantation of a straight-stem prosthesis (11.4 ± 5.9 vs. 4.6 ± 7.4 mm, p = 0.014). Compared with the straight-stem implantation, short-stem implantation caused a significantly greater increase in the varus orientation of the leg (-1.4 ± 0.9 vs. -0.4 ± 1.4°, p = 0.048). There was no significant difference in the positioning of the short-stem prosthesis compared to the straight-stem prosthesis in the proximal femur (3.6 ± 3.1 vs. 2.6 ± 1.9°, p = 0.317). Conclusions: These findings substantiate the impact of prosthesis design on offset and leg alignment. The implantation of short-stems is more variable and requires precise planning. Intraoperative non-physiological offset changes and varus deviation of the leg axis should be avoided. Trial registration: This study was retrospectively registered with the German Clinical Trials Register (DRKS) under the number DRKS00015053 on the 1 August 2018.
Collapse
Affiliation(s)
- Benjamin Fey
- Department of Trauma Surgery and Orthopedics, University Hospital Frankfurt, Goethe University Frankfurt, Marienburgstr. 2, 60528 Frankfurt, Germany; (B.F.); (M.B.); (F.S.)
| | - Marco Brenneis
- Department of Trauma Surgery and Orthopedics, University Hospital Frankfurt, Goethe University Frankfurt, Marienburgstr. 2, 60528 Frankfurt, Germany; (B.F.); (M.B.); (F.S.)
| | - Felix Stief
- Department of Trauma Surgery and Orthopedics, University Hospital Frankfurt, Goethe University Frankfurt, Marienburgstr. 2, 60528 Frankfurt, Germany; (B.F.); (M.B.); (F.S.)
| | - Stefan van Drongelen
- Dr. Rolf M. Schwiete Research Unit for Osteoarthritis, Department of Trauma Surgery and Orthopedics, University Hospital Frankfurt, Goethe University Frankfurt, Marienburgstr. 2, 60528 Frankfurt, Germany
| |
Collapse
|
2
|
Kouyoumdjian P. How the hip-spine relationship influences total hip arthroplasty. Orthop Traumatol Surg Res 2024; 110:103773. [PMID: 38000509 DOI: 10.1016/j.otsr.2023.103773] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Accepted: 06/30/2023] [Indexed: 11/26/2023]
Abstract
INTRODUCTION Motion in the spine, pelvis and hips which make up the spinopelvic femoral complex (SPFC) implies mechanical relationships that help maintain trunk balance and optimize hip functionThe aim of this study was to understand the physiology of the SPFC and evaluate the dysfunctions of the SPFC and their implications for total hip arthroplasty considering the hip-spine relationship. METHODS A review of relevant and comprehensive studies on this subject is reported in order to highlight a pathophysiology that integrates the description of the evaluations of the spine-pelvic and hip parameters and recommendations for the kinematic planning of the THA procedure. The primary objective was to determine which type of hip-spine relationship has the highest risk for THA complications and to become proficient in selecting the priority surgical intervention when both the hip and spine are affected. Finally, this review attempted to assist hip surgeons with surgical technique, tools, implant selection, and goals of planning a THA that requires personalized kinematic alignment. Determine the influence of THA on these kinematics and the effect of stiffness of the lumbopelvic complex on the risk of THA failure. RESULTS When a person sits, the pelvis goes into retroversion and the acetabulum opens forward. This frees the femoral head and neck to allow hip flexion. The opposite - pelvic anteversion - occurs when a person stands. When pelvic mobility is limited, the hip must increase its range of motion to accommodate these posture changes. Disturbances in spinal and pelvic kinematics lead to abnormal hip function, which may contribute to complications following total hip arthroplasty (THA). CONCLUSION A precise evaluation of the parameters governing the SPFC must be taken into account in order to best optimize the placement and choice of THA implants. LEVEL OF EVIDENCE IV.
Collapse
Affiliation(s)
- Pascal Kouyoumdjian
- CHU de Nîmes, Faculté de Médecine Montpellier-Nîmes, Université Montpellier, Hôpital Carémeau, 4, place du Professeur-Robert-Debré, 30900 Nîmes, France.
| |
Collapse
|
3
|
Xie R, Huang J, Wu Q, Qian Y, Jiang D, Li L, Huang L. A Comparison of Radiographic Outcomes after Total Hip Arthroplasty between the Direct Lateral Approach and Posterior Lateral Approach with EOS 2D/3D X-Ray Imaging System. Orthop Surg 2023; 15:1312-1324. [PMID: 37076774 PMCID: PMC10157717 DOI: 10.1111/os.13726] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 03/10/2023] [Accepted: 03/14/2023] [Indexed: 04/21/2023] Open
Abstract
OBJECTIVE The classical approaches for total hip arthroplasty (THA) are the direct lateral approach (DLA) and posterior lateral approach (PLA). There are few studies comparing implant orientation with these two approaches, and the impact of surgical approaches on implant orientation remains controversial. With the rise of the EOS imaging system, we aimed to use it to identify the differences between and factors associated with implant orientation after THA using DLA and PLA. METHODS In our department from January 2019 to December 2021, 321 primary unilateral THAs that used PLA and DLA were enrolled. A total of 201 patients who received PLA and 120 patients who received DLA were included in this study. Two blinded observers measured each case using EOS imaging data. Postoperative imaging metrics and other relevant influencing factors of the two surgical approaches were compared. Postoperative imaging metrics, including the anteversion and inclination of the cup, anteversion of the stem, and combined anteversion were measured based on EOS. Other relevant influencing factors included age, approach, gender, laterality, BMI, anterior pelvic plane inclination, femoral head diameter, femoral offset, lateral pelvic tilt, pelvic incidence, pelvis axial rotation, sacral slope, sagittal pelvic tilt, and surgery time. Multiple linear regression analyses were performed to identify the predictors of acceptability for each imaging data point. RESULTS No dislocation was found in the 321 patients who underwent primary THA during this period. The mean anteversion and combined anteversion of the cups using the DLA were 21.33° ± 17.31° (-51.7°-60.8°) and 33.71° ± 20.85° (-38.8°-77.6°) and PLA were 25.34° ± 12.76° (-5.5°-57.0°) and 42.37° ± 18.85° (-8.7°-84.7°), respectively. The DLA group had smaller anteversion (p = 0.038) and combined anteversion (p < 0.001). We found that surgical approach (p < 0.05), anterior pelvic plane inclination (p < 0.001), gender (p < 0.001), and femoral head diameter (p < 0.001) were important factors affecting acetabular cup anteversion (R2 = 0.375) and combined anteversion (R2 = 0.525). CONCLUSIONS In total hip arthroplasty, different prosthesis installation directions should be made according to different surgical approaches. Compared with the direct lateral approach, the acetabular anteversion can be intentionally enlarged when using the posterolateral approach. Surgical approach, anterior pelvic plane inclination (APPI), gender, and femoral head diameter were significant predictors of prosthesis orientation. The anterior pelvic plane inclination may be a useful standard for assessing the position of the prosthesis using EOS.
Collapse
Affiliation(s)
- Rui Xie
- Department of Orthopaedic SurgeryThe First Affiliated Hospital of Soochow UniversitySuzhouChina
| | - Jun Huang
- Department of Orthopaedic SurgeryThe First Affiliated Hospital of Soochow UniversitySuzhouChina
| | - Qian Wu
- Department of Orthopaedic SurgeryThe First Affiliated Hospital of Soochow UniversitySuzhouChina
| | - Yu‐fan Qian
- Department of Orthopaedic SurgeryThe First Affiliated Hospital of Soochow UniversitySuzhouChina
| | - Dinghua Jiang
- Department of Orthopaedic SurgeryThe First Affiliated Hospital of Soochow UniversitySuzhouChina
| | - Lisong Li
- Department of Orthopaedic SurgeryThe First Affiliated Hospital of Soochow UniversitySuzhouChina
| | - Lixin Huang
- Department of Orthopaedic SurgeryThe First Affiliated Hospital of Soochow UniversitySuzhouChina
| |
Collapse
|
4
|
Shichman I, Ben-Ari E, Sissman E, Singh V, Hepinstall M, Schwarzkopf R. Total knee arthroplasty in patients with lumbar spinal fusion leads to significant changes in pelvic tilt and sacral slope. Arch Orthop Trauma Surg 2023; 143:2103-2110. [PMID: 35536355 DOI: 10.1007/s00402-022-04462-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/10/2021] [Accepted: 04/25/2022] [Indexed: 11/25/2022]
Abstract
BACKGROUND The knee-hip-spine syndrome has been well elucidated in the literature in recent years. The aim of this study was to evaluate the effect of total knee arthroplasty (TKA) on spinopelvic sagittal alignment in patients with and without pre-TKA lumber spinal fusion. METHODS This is a retrospective cohort study of 113 patients who underwent TKA for primary osteoarthritis. Patients were stratified into the following three groups: (1) patients who had pre-TKA spinal fusion (SF, n = 19), (2) patients who had no spinal fusion but experienced pre-TKA flexion contracture (FC, n = 20), and (3) patients without flexion contracture or spinal fusion before TKA (no SF/FC, n = 74). Spinopelvic sagittal alignment parameters, including pelvic tilt (PT), sacral slope (SS), lumbar lordosis (LL), thoracic kyphosis (TK), and plumb line-sacrum distance (SVA) were measured preoperatively and 3 months postoperatively on lateral standing full-body low-dose images. RESULTS TKA resulted in significant pre- to postoperative changes in pelvic tilt (average ∆ PT = - 8.6°, p = 0.018) and sacral slope (average ∆ SS = 8.6°, p = 0.037) in the spinal fusion (SF) group. Non-significant changes in spinopelvic sagittal alignment parameters (PT, SS, LL, TK, SVA) were noted postoperatively in all patients in the FC and the no SF/FC groups. CONCLUSIONS TKA can lead to meaningful changes in spinopelvic alignment in patients with prior lumbar fusion compared to those without spinal fusion. Patients with spinal fusion who are candidates for both hip and knee replacements should consider undergoing TKA first since changes in spinopelvic sagittal alignment can increase the risk of future complications. LEVEL III EVIDENCE Retrospective Cohort Study.
Collapse
Affiliation(s)
- Ittai Shichman
- NYU Langone Health, Division of Adult Reconstruction, Department of Orthopedic Surgery, Hospital of Joint Diseases, NYU Langone Orthopedic Hospital, 301 East 17th Street, New York, NY, 10003, USA
| | - Erel Ben-Ari
- Division of Orthopedic Surgery, Tel-Hashomer "Sheba" Medical Center, Sackler School of Medicine, Ramat Gan, Israel
| | - Ethan Sissman
- Division of Orthopedic Surgery, Tel-Hashomer "Sheba" Medical Center, Sackler School of Medicine, Ramat Gan, Israel
| | - Vivek Singh
- NYU Langone Health, Division of Adult Reconstruction, Department of Orthopedic Surgery, Hospital of Joint Diseases, NYU Langone Orthopedic Hospital, 301 East 17th Street, New York, NY, 10003, USA
| | - Matthew Hepinstall
- NYU Langone Health, Division of Adult Reconstruction, Department of Orthopedic Surgery, Hospital of Joint Diseases, NYU Langone Orthopedic Hospital, 301 East 17th Street, New York, NY, 10003, USA
| | - Ran Schwarzkopf
- NYU Langone Health, Division of Adult Reconstruction, Department of Orthopedic Surgery, Hospital of Joint Diseases, NYU Langone Orthopedic Hospital, 301 East 17th Street, New York, NY, 10003, USA.
| |
Collapse
|
5
|
Ma Z, Tang H, Zhou Y, Wang S, Yang D, Guo S. Assessing component orientation of total hip arthroplasty using the low-dose bi-planar radiographs. BMC Musculoskelet Disord 2022; 23:886. [PMID: 36154920 PMCID: PMC9511787 DOI: 10.1186/s12891-022-05835-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/19/2022] [Accepted: 09/16/2022] [Indexed: 12/04/2022] Open
Abstract
Background Three-dimensional computed tomography (3D CT) reconstruction is the reference standard for measuring component orientation. However, functional cup orientation in standing position is preferable compared with supine position. The low-dose bi-planar radiographs can be used to analyze standing cup component orientation. We aimed to assess the validity and reliability of the component orientation using the low-dose bi-planar radiographs compared with the 3D CT reconstruction, and explore the differences between the functional cup orientation in standing radiographs and supine CT scans. Methods A retrospective study, including 44 patients (50 hips) with total hip arthroplasty (THA), was conducted. CT scans were taken 1 week after surgery and the low-dose bi-planar radiographs were taken in the follow-up 6 weeks later. Component orientation measurement was performed using the anterior pelvic plane and the radiographic coronal plane as reference, respectively. Results The study showed no significant difference in cup anteversion (p = 0.160), cup inclination (p = 0.486), and stem anteversion (p = 0.219) measured by the low-dose bi-planar radiographs and 3D reconstruction. The differences calculated by the Bland–Altman analysis ranged from − 0.4° to 0.6° for the three measured angles. However, the mean absolute error was 4.76 ± 1.07° for functional anteversion (p = 0.035) and 4.02 ± 1.08° for functional inclination (p = 0.030) measured by the bi-planar radiographs and supine CT scans. Conclusions The low-dose bi-planar radiographs are the same reliable and accurate as 3D CT reconstruction to assess post-THA patients’ component orientation, while providing more valuable functional component orientation than supine CT scans.
Collapse
Affiliation(s)
- Zhuyi Ma
- Department of Orthopaedics, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, No.31 Xinjiekou East Street, Xicheng District, Beijing, China
| | - Hao Tang
- Department of Orthopaedics, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, No.31 Xinjiekou East Street, Xicheng District, Beijing, China
| | - Yixin Zhou
- Department of Orthopaedics, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, No.31 Xinjiekou East Street, Xicheng District, Beijing, China.
| | - Siyuan Wang
- Department of Orthopaedics, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, No.31 Xinjiekou East Street, Xicheng District, Beijing, China
| | - Dejin Yang
- Department of Orthopaedics, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, No.31 Xinjiekou East Street, Xicheng District, Beijing, China
| | - Shaoyi Guo
- Department of Orthopaedics, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, No.31 Xinjiekou East Street, Xicheng District, Beijing, China
| |
Collapse
|
6
|
Imaging in Hip Arthroplasty Management-Part 1: Templating: Past, Present and Future. J Clin Med 2022; 11:jcm11185465. [PMID: 36143112 PMCID: PMC9503653 DOI: 10.3390/jcm11185465] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2022] [Revised: 09/11/2022] [Accepted: 09/15/2022] [Indexed: 11/17/2022] Open
Abstract
Hip arthroplasty is a frequently used procedure with high success rates. Its main indications are primary or secondary advanced osteoarthritis, due to acute fracture, osteonecrosis of the femoral head, and hip dysplasia. The goals of HA are to reduce pain and restore normal hip biomechanics, allowing a return to the patient’s normal activities. To reach those goals, the size of implants must suit, and their positioning must meet, quality criteria, which can be determined by preoperative imaging. Moreover, mechanical complications can be influenced by implant size and position, and could be avoided by precise preoperative templating. Templating used to rely on standard radiographs, but recently the use of EOS® imaging and CT has been growing, given the 3D approach provided by these methods. However, there is no consensus on the optimal imaging work-up, which may have an impact on the outcomes of the procedure. This article reviews the current principles of templating, the various imaging techniques used for it, as well as their advantages and drawbacks, and their expected results.
Collapse
|
7
|
Imaging in Hip Arthroplasty Management Part 2: Postoperative Diagnostic Imaging Strategy. J Clin Med 2022; 11:jcm11154416. [PMID: 35956033 PMCID: PMC9369831 DOI: 10.3390/jcm11154416] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2022] [Revised: 07/20/2022] [Accepted: 07/24/2022] [Indexed: 12/04/2022] Open
Abstract
Hip arthroplasty (HA) is a frequently used procedure with high success rates, but 7% to 27% of the patients complain of persistent postsurgical pain 1 to 4 years post-operation. HA complications depend on the post-operative delay, the type of material used, the patient’s characteristics, and the surgical approach. Radiographs are still the first imaging modality used for routine follow-up, in asymptomatic and painful cases. CT and MRI used to suffer from metallic artifacts but are nowadays central in HA complications diagnosis, both having their advantages and drawbacks. Additionally, there is no consensus on the optimal imaging workup for HA complication diagnosis, which may have an impact on patient management. After a brief reminder about the different types of prostheses, this article reviews their normal and pathologic appearance, according to each imaging modality, keeping in mind that few abnormalities might be present, not anyone requiring treatment, depending on the clinical scenario. A diagnostic imaging workup is also discussed, to aid the therapist in his imaging studies prescription and the radiologist in their practical aspects.
Collapse
|
8
|
Hu Y, Ying H, Yu D, Mao Y, Yan M, Li H, Zeng Y, Zhai Z. Positive Correlation Between the Femur Neck Shaft and Anteversion Angles: A Retrospective Computed Tomography Analysis in Patients With Developmental Dysplasia of the Hip. J Arthroplasty 2022; 37:538-543. [PMID: 34923094 DOI: 10.1016/j.arth.2021.12.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/04/2021] [Revised: 11/22/2021] [Accepted: 12/10/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND This study aimed to explore the anatomical correlation between the femoral neck shaft angle (NSA) and femoral anteversion angle (AA) in patients with developmental dysplasia of the hip based on the Crowe classification and provide a novel method to estimate the femoral AA on anteroposterior pelvic radiographs. METHODS A total of 208 patients with dysplastic hips who underwent total hip arthroplasty at our institution were retrospectively included. Preoperative physiological AA and NSA were determined via 3-dimensional computed tomography. Linear regressions and Pearson's coefficients were calculated to assess the correlation between the femoral NSA and femoral AA. RESULTS A total of 416 hips were divided into 5 subgroups: 99 normal, 143 type I, 71 type II, 63 type III, and 40 type IV hips following the Crowe classification. Dysplastic femurs had significantly higher AAs than normal hips (25.2° vs 31.4° vs 33.3° vs 35.5° vs 41.7°). Significant positive correlations between the AA and NSA were observed in normal (r = 0.635), type I (r = 0.700), type II (r = 0.612), and type III (r = 0.638) hips (P < .001); however, no meaningful correlation was observed in type IV hips (r = 0.218, P = .176). CONCLUSION The NSA and AA correlated positively and significantly in the normal and dysplastic Crowe type I-III hips. The relationship between the NSA and AA indicates torsion of the proximal femur and offers an opportunity for straightforward estimation of AA based on NSA.
Collapse
Affiliation(s)
- Yuehao Hu
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, P R China
| | - Hua Ying
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, P R China
| | - Degang Yu
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, P R China
| | - Yuanqing Mao
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, P R China
| | - Mengning Yan
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, P R China
| | - Huiwu Li
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, P R China
| | - Yiming Zeng
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, P R China
| | - Zanjing Zhai
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, P R China
| |
Collapse
|
9
|
Tian B, Cui L, Jiang W. The diagnostic effect of α-defensin, D-dimer, and IL-6 in periprosthetic joint infection: A systematic review and diagnostic meta-analysis. J Orthop Surg (Hong Kong) 2021; 28:2309499020971861. [PMID: 33225796 DOI: 10.1177/2309499020971861] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
BACKGROUND Periprosthetic joint infection (PJI) is the most common complication after artificial joint replacement as previously reported. However, the main problem at present is its difficulty in diagnosis. This systematic review and meta-analysis aimed to compare the diagnostic accuracy of α-defensin, D-dimer, and interleukin-6 (IL-6) in clinical practice. METHOD Online databases were systematically searched until June 18th, 2020 with keywords and medical sub-headings terms. Studies mentioned the sensitivity and specificity of biological markers in detecting PJI were included in our study. The sensitivity, specificity, and diagnostic odds ratios (DORs) were obtained after integration. RESULTS A total of 34 studies with 1036 patients diagnosing as PJI were included for comparing α-defensin, D-dimer, and IL-6. The sensitivity and specificity of α-defensin for PJI were 0.88 and 0.96, and the DOR was 189 (95% CI 72-496), respectively. The sensitivity and specificity of D-dimer (0.82 and 0.72) and IL-6 (0.80 and 0.89) were lower than α-defensin. CONCLUSION The detection of α-defensin is a promising biomarker for diagnosing PJI. The optional cut-off needs to be curtained when using other biomarkers.
Collapse
Affiliation(s)
- Baozhong Tian
- Bone surgery, Affiliated Hospital of Jilin Medical University, Jilin City, China
| | - Liwen Cui
- Changyi District Center for Disease Control and Prevention, Jilin City, China
| | | |
Collapse
|
10
|
Mayr HO, Schmidt JP, Haasters F, Bernstein A, Schmal H, Prall WC. Anteversion Angle Measurement in Suspected Torsional Malalignment of the Femur in 3-Dimensional EOS vs Computed Tomography-A Validation Study. J Arthroplasty 2021; 36:379-386. [PMID: 32826141 DOI: 10.1016/j.arth.2020.07.058] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/25/2020] [Revised: 07/19/2020] [Accepted: 07/22/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Computed tomography (CT) scan is the standard for assessment of femoral torsion. This observational study was conducted to evaluate the comparability of the EOS radiation dose scanning system (EOS imaging, Paris, France) and the CT scan in patients with suspected torsional malalignment of the femur. METHODS Patients with suspected torsional malalignment of the femur were included in a study for surgical planning. The primary endpoint was to compare the 3-dimensional radiological (EOS) imaging system with the CT scan to determine femoral anteversion (AV) angle. Three independent raters performed measurements. Comparability of CT scan and EOS values was assessed by Pearson correlation, t test, interobserver reliability, and intraobserver reliability (Cronbach alpha). RESULTS About 34 femora were examined. Interobserver reliability/intraobserver reliability was 0.911 of 0.955 for EOS and 0.934 of 0.934 for CT scan. EOS system revealed an AV angle of 12.2° ± 10.0° (-15.0° to 32.0°). CT examinations showed an AV angle of 12.6° ± 9.2° (-3.2° to 35.6°). About 11 hips featured physiological AV, 14 hips showed decreased AV (<10°) or retroversion (<0°), and 9 hips showed increased AV (>20°). Overall, a strong Pearson correlation of τ = 0.855 and a highly significant correlation in the t test for both methods was seen. In patients with decreased AV, retroversion, or increased AV, Pearson correlation only resulted in a moderate/low correlation of τ = 0.495 and τ = 0.292. The t test showed no significant correlation at malrotation. CONCLUSION In torsional malalignment, EOS does not have correlation with CT measurements. In contrast to CT scan, EOS allows femoral torsion measurement independent of legs' positioning.
Collapse
Affiliation(s)
- Hermann O Mayr
- Department of Orthopedics and Trauma Surgery, Medical Center, Faculty of Medicine, Albert-Ludwigs-University of Freiburg, Freiburg, Germany
| | - Jan-Peter Schmidt
- Department of Knee, Hip and Shoulder Surgery, Schoen Clinic Munich Harlaching, Academic Teaching Hospital of the Paracelsus Medical University (PMU), Salzburg, Austria
| | - Florian Haasters
- Department of General, Trauma and Reconstructive Surgery, Munich University Hospital, Ludwig-Maximilians-University (LMU), Munich, Germany
| | - Anke Bernstein
- Department of Orthopedics and Trauma Surgery, Medical Center, Faculty of Medicine, Albert-Ludwigs-University of Freiburg, Freiburg, Germany
| | - Hagen Schmal
- Department of Orthopedics and Trauma Surgery, Medical Center, Faculty of Medicine, Albert-Ludwigs-University of Freiburg, Freiburg, Germany; Department of Orthopaedic Surgery, University Hospital Odense, Odense, Denmark
| | - Wolf C Prall
- Department of Orthopedics and Trauma Surgery, Medical Center, Faculty of Medicine, Albert-Ludwigs-University of Freiburg, Freiburg, Germany; Department of General, Trauma and Reconstructive Surgery, Munich University Hospital, Ludwig-Maximilians-University (LMU), Munich, Germany
| |
Collapse
|
11
|
Harold RE, Delagrammaticas D, Keller T, Butler B, Stover MD, Manning DW. Are single plane intraoperative and biplanar postoperative radiographic measurements of acetabular cup position the same? Hip Int 2020; 30:530-535. [PMID: 31242760 DOI: 10.1177/1120700019859902] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
PURPOSE Supine positioning and the use of fluoroscopy during direct anterior approach total hip arthroplasty (DAA THA) have been reported to improve acetabular component positioning. This study aims to compare 2-dimensional intraoperative radiographic RadLink measurements of acetabular component position with 3-dimensional postoperative 3D SterEOS measurements. METHODS Intraoperative fluoroscopy and RadLink (El Segundo, CA, USA) were used to measure acetabular cup position intraoperatively in 48 consecutive patients undergoing DAA THA. Cup position was measured on 6-week postoperative standing EOS images using 3D SterEOS software (EOS Imaging, SA, Paris, France) and compared to RadLink findings using Student's t-test. Safe-zone outliers were identified. We evaluated for measurement difference of > +/- 5°. RESULTS RadLink acetabular cup abduction measurement (mean 43.0°) was not significantly different than 3D SterEOS in the anatomic plane (mean 42.6°, p = 0.50) or in the functional plane (mean 42.7°, p = 0.61). RadLink acetabular cup anteversion measurement (mean 17.9°) was significantly different than 3D SterEOS in both the anatomic plane (mean 20.6°, p = 0.022) and the functional plane (mean 21.2°, p = 0.002). RadLink identified 2 cups outside of the safe-zone. However, SterEOS identified 12 (anatomic plane) and 10 (functional plane) outside of the safe-zone. In the functional plane, 58% of anteversion and 92% of abduction RadLink measurements were within +/- 5° of 3D SterEOS. CONCLUSIONS Intraoperative fluoroscopic RadLink acetabular anteversion measurements are significantly different than 3D SterEOS measurements, while abduction measurements are similar. Significantly more acetabular cups were noted to be outside of the safe-zone when evaluated with 3D SterEOS versus RadLink.
Collapse
Affiliation(s)
- Ryan E Harold
- Department of Orthopaedic Surgery, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | - Dimitri Delagrammaticas
- Department of Orthopaedic Surgery, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | - Tyler Keller
- Department of Orthopaedic Surgery, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | - Bennet Butler
- Department of Orthopaedic Surgery, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | - Michael D Stover
- Department of Orthopaedic Surgery, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | - David W Manning
- Department of Orthopaedic Surgery, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| |
Collapse
|
12
|
Perronne L, Haehnel O, Chevret S, Wybier M, Hannouche D, Nizard R, Bousson V. How is quality of life after total hip replacement related to the reconstructed anatomy? A study with low-dose stereoradiography. Diagn Interv Imaging 2020; 102:101-107. [PMID: 32532576 DOI: 10.1016/j.diii.2020.05.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2020] [Revised: 05/11/2020] [Accepted: 05/13/2020] [Indexed: 02/04/2023]
Abstract
PURPOSE The purpose of this study was to evaluate the relationships between the three-dimensional anatomy of operated hip in standing position using low-dose stereo-radiography imaging system and postoperative hip disability and osteoarthritis outcome score (HOOS) after total hip arthroplasty (THA). MATERIAL AND METHODS A total of 123 patients who underwent THA during a one-year period were included. There were 50 men and 73 women with a mean age of 67.3±13.6 (SD) years (range: 19-89 years). All patients underwent pre- and postoperative low-dose stereo-radiography examination and completed a HOOS form (score from 0 to 100, 100 for full satisfaction). We recorded 16 anatomical parameters before THA, and 15 after THA. After binary transformation of HOOS score using 70 as threshold value, outcome was assessed using logistic or generalised linear models. RESULTS A total of 103 patients (103/123; 83.7%) had a HOOS score≥70 and were considered as the satisfied group. A significant difference in pelvic incidence (the angle between a line perpendicular to the sacral plate at its midpoint and a line connecting the same point to the centre of the bicoxofemoral axis) was found between the satisfied 56.4±10.4 (SD)° (range: 31-85°) and the unsatisfied group 48.7±8.9 (SD)° (range: 40-65) (P=0.006). The relative variation of offset (distance from the centre of rotation of the femoral head to a line bisecting the long axis of the femur) compared to the contralateral hip was -7% in the satisfied group and 7.2% in the unsatisfied group (P=0.01). CONCLUSION Pelvic incidence, a parameter independent of the reconstructed anatomy, probably influences the quality of life of patients with THA, via pelvic compensatory capabilities. A loss of femoral offset negatively influences the satisfaction of patients.
Collapse
Affiliation(s)
- L Perronne
- Department of Radiology, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, 75010 Paris, France; Université de Paris, 75010 Paris, France.
| | - O Haehnel
- Université de Paris, 75010 Paris, France; Department of Orthopedic Surgery, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, 75010 Paris, France
| | - S Chevret
- Université de Paris, 75010 Paris, France; Department of Clinical Research, Hôpital Saint-Louis, Assistance Publique-Hôpitaux de Paris, 75010 Paris, France
| | - M Wybier
- Department of Radiology, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, 75010 Paris, France
| | - D Hannouche
- Department of Orthopedic Surgery, Hôpital Universitaire de Genève, 1205 Genève, Switzerland
| | - R Nizard
- Université de Paris, 75010 Paris, France; Department of Orthopedic Surgery, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, 75010 Paris, France
| | - V Bousson
- Department of Radiology, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, 75010 Paris, France; Université de Paris, 75010 Paris, France
| |
Collapse
|
13
|
Kobayashi H, Cech A, Kase M, Pagenstart G, Carrillon Y, O'Loughlin PF, Bothorel H, Aït-Si-Selmi T, Bonnin MP. Pre-operative templating in THA. Part II: a CT-based strategy to correct architectural hip deformities. Arch Orthop Trauma Surg 2020; 140:551-562. [PMID: 31974697 DOI: 10.1007/s00402-020-03341-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/14/2019] [Indexed: 12/16/2022]
Abstract
INTRODUCTION Pre-operative templating for total hip arthroplasty (THA) remains inaccurate due to improper magnification and alignment. We aimed to describe an improved templating strategy using computed tomography (CT) to predict component sizes and offsets with greater accuracy. MATERIALS AND METHODS We analysed 184 CT images acquired for pre-operative templating of primary THA. We aimed to restore native (pre-arthritic) femoral offset and limb length, by raising the head center to the level of the templated cup center cranio-caudally, but maintaining the pathologic (pre-operative) head center medio-laterally (except in medialized hips). Acetabular offset (AO) and femoral offset (FO) were measured on pre-operative CT scans, during acetate templating, and on post-operative true antero-posterior radiographs. RESULTS The post-operative offsets were within ± 5 mm from templated estimates in 174 hips (91%) for AO, in 116 hips (61%) for FO, in 111 hips (58%) for GO, and in 134 hips (70%) for neck cut level. The post-operative hip architecture reproduced the templated hip architecture within ±5 mm in 77 hips (40%). The agreement between planned and post-operative parameters was moderate for stem size (0.57), cup size (0.62), AO (0.50), but fair for FO (0.45). The AO decreased in most arthritic types, notably in lateralized hips (6.6 mm), but remained unchanged in medialized hips. The FO increased in most arthritic types (1.8-3.1 mm) but remained unchanged in medialized and lateralized hips. CONCLUSIONS We described a strategy for pre-operative templating in THA. Despite the accuracy of CT, the authors found significant variations between planned and post-operative reconstructions, which suggest that pre-operative templating should only be used as an approximate guide.
Collapse
Affiliation(s)
- Hideo Kobayashi
- Department of Orthopaedic Surgery, Juntendo University, Bunkyo-ku, Tokyo, Japan
| | - Alexandre Cech
- Ramsay Santé, Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, Lyon, France
| | - Masanori Kase
- Department of Orthopaedic Surgery, Nissan Tamagawa Hospital, Setagayaku, Tokyo, Japan
| | - Geert Pagenstart
- Department of Clinical Research, University of Basel, Basel, Switzerland.,Clarahof Clinic of Orthopaedic Surgery, Merian-Iselin-Hospital Swiss Olympic Medical Center, Basel, Switzerland.,Knee Institute Basel, Basel, Switzerland
| | - Yannick Carrillon
- Ramsay Santé, Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, Lyon, France
| | - Padhraig F O'Loughlin
- Ramsay Santé, Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, Lyon, France.,Cork University Hospital, South Infirmary, Victoria University Hospital, Mater Private Cork, Cork, Ireland
| | - Hugo Bothorel
- ReSurg SA, Rue Saint-Jean 22, 1260, Nyon, Switzerland.
| | - Tarik Aït-Si-Selmi
- Ramsay Santé, Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, Lyon, France.,Artro Institute, Lyon, France
| | - Michel P Bonnin
- Ramsay Santé, Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, Lyon, France.,Artro Institute, Lyon, France
| |
Collapse
|
14
|
Zhao JX, Su XY, Zhao Z, Xiao RX, Zhang LC, Tang PF. Radiographic assessment of the cup orientation after total hip arthroplasty: a literature review. ANNALS OF TRANSLATIONAL MEDICINE 2020; 8:130. [PMID: 32175423 DOI: 10.21037/atm.2019.12.150] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Optimal acetabular cup orientation is of substantial importance to good long-term function and low complication rates after total hip arthroplasty (THA). The radiographic anteversion (RA) and inclination (RI) angles of the cup are typically studied due to the practicability, simplicity, and ease of interpretation of their measurements. A great number of methods have been developed to date, most of which have been performed on pelvic or hip anteroposterior radiographs. However, there are primarily two influencing factors for these methods: X-ray offset and pelvic rotation. In addition, there are three types of pelvic rotations about the transverse, longitudinal, and anteroposterior axes of the body. Their effects on the RA and RI angles of the cup are interactively correlated with the position and true orientation of the cup. To date, various fitted or analytical models have been established to disclose the correlations between the X-ray offset and pelvic rotation and the RA and RI angles of the cup. Most of these models do not incorporate all the potential influencing parameters. Advanced methods for performing X-ray offset and pelvic rotation corrections are mainly performed on a single pelvic AP radiograph, two synchronized radiographs, or a two-dimensional/three-dimensional (2D-3D) registration system. Some measurement systems, originally developed for evaluating implant migration or wear, could also be used for correcting the X-ray offset and pelvic rotation simultaneously, but some drawbacks still exist with these systems. Above all, the 2D-3D registration technique might be an alternative and powerful tool for accurately measuring cup orientation. In addition to the current methods used for postoperative assessment, navigation systems and augmented reality are also used for the preoperative planning and intraoperative guidance of cup placement. With the continuing development of artificial intelligence and machine learning, these techniques could be incorporated into robot-assisted orthopaedic surgery in the future.
Collapse
Affiliation(s)
- Jing-Xin Zhao
- Department of Orthopaedics, the First Medical Centre, Chinese PLA General Hospital, Beijing 100853, China.,National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation, Beijing 100853, China
| | - Xiu-Yun Su
- Department of Orthopaedics, the First Medical Centre, Chinese PLA General Hospital, Beijing 100853, China.,Intelligent and Digital Surgery Innovation Center, Southern University of Science and Technology Hospital, Shenzhen, Guangdong 518055, China
| | - Zhe Zhao
- Department of Orthopaedics, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, Beijing 102218, China
| | - Ruo-Xiu Xiao
- School of Computer and Communication Engineering, University of Science and Technology Beijing, Beijing 100083, China
| | - Li-Cheng Zhang
- Department of Orthopaedics, the First Medical Centre, Chinese PLA General Hospital, Beijing 100853, China.,National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation, Beijing 100853, China
| | - Pei-Fu Tang
- Department of Orthopaedics, the First Medical Centre, Chinese PLA General Hospital, Beijing 100853, China.,National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation, Beijing 100853, China
| |
Collapse
|
15
|
Fougeron N, Rohan PY, Macron A, Travert C, Pillet H, Skalli W. Subject specific finite element mesh generation of the pelvis from biplanar x-ray images: application to 120 clinical cases. Comput Methods Biomech Biomed Engin 2018; 21:408-412. [PMID: 29969279 DOI: 10.1080/10255842.2018.1469624] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
Several Finite Element (FE) models of the pelvis have been developed to comprehensively assess the onset of pathologies and for clinical and industrial applications. However, because of the difficulties associated with the creation of subject-specific FE mesh from CT scan and MR images, most of the existing models rely on the data of one given individual. Moreover, although several fast and robust methods have been developed for automatically generating tetrahedral meshes of arbitrary geometries, hexahedral meshes are still preferred today because of their distinct advantages but their generation remains an open challenge. Recently, approaches have been proposed for fast 3D reconstruction of bones based on X-ray imaging. In this study, we adapted such an approach for the fast and automatic generation of all-hexahedral subject-specific FE models of the pelvis based on the elastic registration of a generic mesh to the subject-specific target in conjunction with element regularity and quality correction. The technique was successfully tested on a database of 120 3D reconstructions of pelvises from biplanar X-ray images. For each patient, a full hexahedral subject-specific FE mesh was generated with an accurate surface representation.
Collapse
Affiliation(s)
- Nolwenn Fougeron
- a Institut de Biomécanique Humaine Georges Charpak, Arts et Métiers , Paris , France
| | - Pierre-Yves Rohan
- a Institut de Biomécanique Humaine Georges Charpak, Arts et Métiers , Paris , France
| | - Aurélien Macron
- a Institut de Biomécanique Humaine Georges Charpak, Arts et Métiers , Paris , France.,b CEA, LETI, CLINATEC, MINATEC Campus , Grenoble , France
| | - Christophe Travert
- a Institut de Biomécanique Humaine Georges Charpak, Arts et Métiers , Paris , France
| | - Hélène Pillet
- a Institut de Biomécanique Humaine Georges Charpak, Arts et Métiers , Paris , France
| | - Wafa Skalli
- a Institut de Biomécanique Humaine Georges Charpak, Arts et Métiers , Paris , France
| |
Collapse
|
16
|
Rivière C, Lazic S, Dagneaux L, Van Der Straeten C, Cobb J, Muirhead-Allwood S. Spine-hip relations in patients with hip osteoarthritis. EFORT Open Rev 2018; 3:39-44. [PMID: 29657844 PMCID: PMC5890167 DOI: 10.1302/2058-5241.3.170020] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
Patients with hip osteoarthritis often have an abnormal spine-hip relation (SHR), meaning the presence of a clinically deleterious spine-hip and/or hip-spine syndrome. Definition of the individual SHR is ideally done using the EOS® imaging system or, if not available, with conventional lumbopelvic lateral radiographs. By pre-operatively screening patients with abnormal SHR, it is possible to refine total hip replacement (THR) surgical planning, which may improve outcomes. An important component of the concept of kinematically aligned total hip arthroplasty (KA THA) consists of defining the optimal acetabular cup design and orientation based on the assessment of an individual’s SHR, and use of the transverse acetabular ligament to adjust the cup positioning. The Bordeaux classification might advance the understanding of SHR and hopefully help improve THR outcomes.
Cite this article: EFORT Open Rev 2018;3:39-44. DOI: 10.1302/2058-5241.3.170020
Collapse
Affiliation(s)
- Charles Rivière
- MSK Lab, Imperial College London, UK.,South West London Elective Orthopaedic Centre, UK
| | - Stefan Lazic
- South West London Elective Orthopaedic Centre, UK
| | | | | | | | | |
Collapse
|
17
|
Tokunaga K, Okamoto M, Watanabe K. Implant Orientation Measurement After THA Using the EOS X-Ray Image Acquisition System. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2018; 1093:335-343. [PMID: 30306493 DOI: 10.1007/978-981-13-1396-7_26] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
We investigated the accuracy of measuring implant orientation after THA in standing position using EOS system (EOS Imaging Inc., Paris, France). Ninety patients who underwent THA were subjected to this study by comparing angles measured by EOS system and those measured from CT scans using 3D image analyzing software, ZedHip (LEXI, Tokyo, Japan). The radiographic cup inclination and anatomical cup anteversion were measured with respect to the anterior pelvic plane (APP) coordinate. The femoral stem antetorsion was analyzed by measuring the angles between the stem neck axis and the post-condylar axis in the femoral functional axis coordinate.The differences (mean ± SD) (range of 95%CI) between angles measured by EOS system and those from CT scans in the cup inclination, cup anteversion, and stem antetorsion were - 2.3° ± 2.7° (-2.8°∼ - 1.7°), -0.1° ± 5.0° (-1.2°∼0.9°), and - 1.3° ± 6.5° (-2.7°∼0.1°), respectively. Cup inclination measured on 14 hips, cup anteversion measured on 28 hips, and stem antetorsion measured on 27 hips were classified as outliers whose differences were over 5°. Difficulties in defining the reference points for APP correlated with the incidences of the outliers in cup orientation measurements.We could not set new reference points on the 3D bone surface models reconstructed by EOS system, so we have to use reference points defined on 2D images. In addition, the APP coordinate in EOS system was not the same as the standard definition. EOS system may not be used to measure the implant positions after THA until these problems will be improved.
Collapse
Affiliation(s)
- Kunihiko Tokunaga
- Niigata Hip Joint Center, Kameda Daiichi Hospital, Niigata City, Japan.
| | - Masashi Okamoto
- Department of Radiology, Kameda Daiichi Hospital, Niigata City, Japan
| | - Kenji Watanabe
- Department of Orthopedic Surgery, Kameda Daiichi Hospital, Niigata City, Japan
| |
Collapse
|
18
|
Rivière C, Lazennec JY, Van Der Straeten C, Auvinet E, Cobb J, Muirhead-Allwood S. The influence of spine-hip relations on total hip replacement: A systematic review. Orthop Traumatol Surg Res 2017; 103:559-568. [PMID: 28373138 DOI: 10.1016/j.otsr.2017.02.014] [Citation(s) in RCA: 110] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/10/2016] [Revised: 02/27/2017] [Accepted: 02/28/2017] [Indexed: 02/02/2023]
Abstract
Sagittal pelvic kinematics along with spino-pelvic angular parameters have recently been studied by numerous investigators for their effect on total hip replacement (THR) clinical outcomes, but many issue of spine-hip relations (SHR) are currently unexplored. Therefore, our review aims at clarifying the following questions: is there any evidence of a relationship between articular impingement/dislocation risk in primary THR and (1) certain sagittal pelvic kinematics patterns, (2) pelvic incidence, and (3) types of SHRs? A systematic review of the existing literature utilising PubMed and Google search engines was performed in January 2017. Only clinical or computational studies published in peer-reviewed journals over the last five years in either English or French were reviewed. We identified 769 reports, of which 12 met our eligibility criteria. A review of literature shows that sagittal pelvic kinematics, but not the pelvic incidence, influences the risk of prosthetic impingement/dislocation. We found no study having assessed the relationship between this risk and the types of SHRs. Sagittal pelvic kinematics is highly variable among individuals and certain kinematic patterns substantially influences the risk of prosthetic impingement/dislocation. Recommendations for cup positioning are therefore switching from a systematic to a patient-specific approach, with the standing cup orientation Lewinneck safe zone progressively giving way to a new parameter of interest: the functional orientation of the cup. Based on a recently published classification for SHRs, We propose a new concept of "kinematically aligned THR" for the purposes of THR planning. Further studies are needed to investigate the relevance of such a classification towards the assumptions and hypothesis we have made. Level of evidence,- Level IV, systematic review of level III and IV studies.
Collapse
Affiliation(s)
- C Rivière
- MSK Lab, 7, Laboratory Block, Charing Cross Campus, Imperial college of London, W6 8RP London, UK.
| | - J-Y Lazennec
- Service de chirurgie orthopédique, hôpital Pitié-Salpêtrière, université Pierre-et-Marie-Curie, 47-83, boulevard de l'Hôpital, 75634 Paris cedex 13, France
| | - C Van Der Straeten
- MSK Lab, 7, Laboratory Block, Charing Cross Campus, Imperial college of London, W6 8RP London, UK
| | - E Auvinet
- MSK Lab, 7, Laboratory Block, Charing Cross Campus, Imperial college of London, W6 8RP London, UK
| | - J Cobb
- MSK Lab, 7, Laboratory Block, Charing Cross Campus, Imperial college of London, W6 8RP London, UK
| | | |
Collapse
|