1
|
Nees TA, Mueller CT, Innmann MM, Spranz DM, Westhauser F, Renkawitz T, Reiner T, Walker T. Assessment Accuracy of 2D vs. 3D Imaging for Custom-Made Acetabular Implants in Revision Hip Arthroplasty. J Pers Med 2024; 14:808. [PMID: 39202000 PMCID: PMC11355157 DOI: 10.3390/jpm14080808] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2024] [Revised: 07/26/2024] [Accepted: 07/27/2024] [Indexed: 09/03/2024] Open
Abstract
Revision total hip arthroplasty (rTHA) presents significant challenges, particularly in patients with severe acetabular bone defects. Traditional treatment options often fall short, leading to the emergence of custom-made 3D-printed acetabular implants. Accurate assessment of implant positioning is crucial for ensuring optimal postoperative outcomes and for providing feedback to the surgical team. This single-center, retrospective cohort study evaluates the accuracy of standard 2D radiographs versus 3D CT scans in assessing the positioning of these implants, aiming to determine if 2D imaging could serve as a viable alternative for the postoperative evaluation. We analyzed the implant positions of seven rTHA patients with severe acetabular defects (Paprosky ≥ Type IIIA) using an alignment technique that integrates postoperative 2D radiographs with preoperative CT plans. Two independent investigators, one inexperienced and one experienced, measured the positioning accuracy with both imaging modalities. Measurements included translational shifts from the preoperatively templated implant position in the craniocaudal (CC), lateromedial (LM), and ventrodorsal (VD) directions, as well as rotational differences in anteversion (AV) and inclination (INCL). The study demonstrated that 2D radiographs, when aligned with preoperative CT data, could accurately assess implant positions with precision nearly comparable to that of 3D CT scans. Observed deviations were 1.4 mm and 2.7 mm in CC and LM directions, respectively, and 3.6° in AV and 0.7° in INCL using 2D imaging, all within clinically acceptable ranges. For 3D CT assessments, mean interobserver variability was up to 0.9 mm for translational shifts and 1.4° for rotation, while for 2D alignment, observer differences were 1.4 mm and 3.2° for translation and rotation, respectively. Comparative analysis of mean results from both investigators, across all dimensions (CC, LM, AV, and INCL) for 2D and 3D matching, showed no significant differences. In conclusion, conventional anteroposterior 2D radiographs of the pelvis can sufficiently determine the positioning of custom-made acetabular implants in rTHA. This suggests that 2D radiography is a viable alternative to 3D CT scans, potentially enhancing the implementation and quality control of advanced implant technologies.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | - Tilman Walker
- Department of Orthopaedics, Heidelberg University Hospital, Schlierbacher Landstraße 200a, 69118 Heidelberg, Germany
| |
Collapse
|
2
|
Romagnoli M, Zaffagnini M, Carillo E, Raggi F, Casali M, Leardini A, Marcheggiani Muccioli GM, Grassi A, Zaffagnini S. Custom-made implants for massive acetabular bone loss: accuracy with CT assessment. J Orthop Surg Res 2023; 18:742. [PMID: 37777776 PMCID: PMC10544156 DOI: 10.1186/s13018-023-04230-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/07/2023] [Accepted: 09/22/2023] [Indexed: 10/02/2023] Open
Abstract
BACKGROUND Custom-made implants are a valid option in revision total hip arthroplasty to address massive acetabular bone loss. The aim of this study was to assess the accuracy of custom-made acetabular implants between preoperative planning and postoperative positioning using CT scans. METHODS In a retrospective analysis, three patients who underwent an acetabular custom-made prosthesis were identified. The custom-made designs were planned through 3D CT analysis considering surgical points of attention. The accuracy of intended implants positioning was assessed by comparing pre- and postoperative CT analyzing the center of rotation (CoR), anteversion, inclination, screws, and implant surface in contact with the bone. RESULTS The three cases presented satisfactory accuracy in positioning. A malpositioning in the third case was observed due to the posterization of the CoR of the implant of more than 10 mm. The other CoR vectors considered in the third patient and all vectors in the other two cases fall within 10 mm. All the cases were positioned with a difference of less than 10° of anteversion and inclination with respect to the planning. CONCLUSIONS The current case series revealed promising accuracy in the positioning of custom-made acetabular prosthesis comparing the planned implant in preoperative CT with postoperative CT.
Collapse
Affiliation(s)
- Matteo Romagnoli
- Ortopedia e Traumatologia Rizzoli Argenta, Via Nazionale Ponente 5, 44011, Argenta, FE, Italy
| | - Marco Zaffagnini
- Clinica Ortopedica e Traumatologica 2, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136, Bologna, BO, Italy.
| | - Eleonora Carillo
- Clinica Ortopedica e Traumatologica 2, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136, Bologna, BO, Italy
| | - Federico Raggi
- Clinica Ortopedica e Traumatologica 2, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136, Bologna, BO, Italy
| | - Marco Casali
- Ortopedia e Traumatologia Rizzoli Argenta, Via Nazionale Ponente 5, 44011, Argenta, FE, Italy
| | - Alberto Leardini
- Movement Analysis Laboratory, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano, 1/10, 40136, Bologna, Italy
| | | | - Alberto Grassi
- Clinica Ortopedica e Traumatologica 2, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136, Bologna, BO, Italy
| | - Stefano Zaffagnini
- Clinica Ortopedica e Traumatologica 2, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136, Bologna, BO, Italy
| |
Collapse
|
3
|
Romagnoli M, Casali M, Zaffagnini M, Cucurnia I, Raggi F, Reale D, Grassi A, Zaffagnini S. Tricalcium Phosphate as a Bone Substitute to Treat Massive Acetabular Bone Defects in Hip Revision Surgery: A Systematic Review and Initial Clinical Experience with 11 Cases. J Clin Med 2023; 12:jcm12051820. [PMID: 36902607 PMCID: PMC10003370 DOI: 10.3390/jcm12051820] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Revised: 01/28/2023] [Accepted: 02/22/2023] [Indexed: 03/12/2023] Open
Abstract
The use of tricalcium phosphate (TCP) as a bone substitute is gaining increasing interest to treat severe acetabular bone defects in revision total hip arthroplasty (rTHA). The aim of this study was to investigate the evidence regarding the efficacy of this material. A systematic review of the literature was performed according to the PRISMA and Cochrane guidelines. The study quality was assessed using the modified Coleman Methodology Score (mCMS) for all studies. A total of eight clinical studies (230 patients) were identified: six on TCP used as biphasic ceramics composed of TCP and hydroxyapatite (HA), and two as pure-phase ceramics consisting of TCP. The literature analysis showed eight retrospective case series, of which only two were comparative studies. The mCMS showed an overall poor methodology (mean score 39.5). While the number of studies and their methodology are still limited, the available evidence suggests safety and overall promising results. A total of 11 cases that underwent rTHA with a pure-phase ceramic presented satisfactory clinical and radiological outcomes at initial short-term follow-up. Further studies at long-term follow-up, involving a larger number of patients, are needed before drawing more definitive conclusions on the potential of TCP for the treatment of patients who undergo rTHA.
Collapse
Affiliation(s)
- Matteo Romagnoli
- Ortopedia e Traumatologia Rizzoli Argenta, 44011 Argenta, FE, Italy
| | - Marco Casali
- Ortopedia e Traumatologia Rizzoli Argenta, 44011 Argenta, FE, Italy
- Correspondence:
| | - Marco Zaffagnini
- Clinica Ortopedica e Traumatologica 2, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, BO, Italy
| | - Ilaria Cucurnia
- Ortopedia e Traumatologia Rizzoli Argenta, 44011 Argenta, FE, Italy
| | - Federico Raggi
- Clinica Ortopedica e Traumatologica 2, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, BO, Italy
| | - Davide Reale
- Ortopedia e Traumatologia Rizzoli Argenta, 44011 Argenta, FE, Italy
| | - Alberto Grassi
- Clinica Ortopedica e Traumatologica 2, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, BO, Italy
| | - Stefano Zaffagnini
- Clinica Ortopedica e Traumatologica 2, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, BO, Italy
| |
Collapse
|
4
|
Zucchini R, Sambri A, Giannini C, Fiore M, Calamelli C, Donati DM, De Paolis M. Porous tantalum acetabular cups for reconstructions after peri-acetabular resections of primary bone tumours. Hip Int 2023; 33:81-86. [PMID: 33829914 DOI: 10.1177/11207000211001552] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION Periacetabular reconstruction after resection of primary bone tumour is a very demanding procedure. They are frequently associated with scarce functional results and a high rate of complications. We report a series of patients with periacetabular resections for primary bone tumours and reconstruction with a porous tantalum (PT) acetabular cup (AC). MATERIALS AND METHODS 27 patients (median age 30 years) were included, being affected by primary bone tumours of the pelvis and treated with peri-acetabular resection and reconstruction with a PT AC. The diagnoses were 13 osteosarcomas, 7 chondrosarcomas and 7 Ewing sarcomas. Function was assessed with the Harris Hip Score and complications were classified according to Zeifang. RESULTS The median follow-up was 70 months. 1 patient required removal of the PT AC because of implant associated infection 55 months after surgery. There was 1 hip dislocation and no case of aseptic loosening. At final follow-up, the median HHS was 81 points (range 48-92). CONCLUSIONS The used PT AC had good medium-term survival rates and good functional results. This technique is a viable reconstructive option after resections of periacetabular primary bone sarcomas.
Collapse
Affiliation(s)
| | - Andrea Sambri
- University of Bologna, Italy.,IRCCS Policlinico di Sant'Orsola, Bologna, Italy
| | | | | | | | - Davide Maria Donati
- IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy.,University of Bologna, Italy
| | | |
Collapse
|
5
|
Cimatti P, Andreoli I, Busacca M, Govoni M, Vivarelli L, Del Piccolo N, Maso A, Stagni C, Pignatti G. An Observational Prospective Clinical Study for the Evaluation of a Collagen-Hydroxyapatite Composite Scaffold in Hip Revision Surgery. J Clin Med 2022; 11:6372. [PMID: 36362601 PMCID: PMC9654158 DOI: 10.3390/jcm11216372] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2022] [Revised: 10/12/2022] [Accepted: 10/25/2022] [Indexed: 04/23/2024] Open
Abstract
One of the greatest challenges of hip revision surgery is the need to restore extensive bone loss by creating a stable reconstruction with long-term durability. The present observational, investigator-initiated prospective study was carried out to evaluate the clinical and radiological results of the use of a commercial biomimetic collagen-hydroxyapatite composite biomaterial (RegenOss) applied in hip revision surgery. Thirty-three patients who underwent hip revision were included in this study, and 29 received up to 2 years of follow-up. The acetabulum was reconstructed using an uncemented hemispherical shell both with or without an iliac fixation stem. Functional recovery was assessed according to the Harris Hip Score (HHS) at the pre-hospitalisation check-up, and at 6-, 12-, and 24-month follow-ups. Radiological evaluation consisting of X-ray analyses (6, 12, and 24 month follow-ups) and CT scan exams (within 10 weeks post-surgery and at 12-month follow-up) were performed to evaluate the reduction in bone defect and new bone regeneration. All the patients reported a complete recovery and a considerable improvement in functional outcome assessed by the HHS, which was significantly higher at all the follow-ups than at pre-hospitalisation. Moreover, radiological assessments revealed good scaffold integration. Overall, collected data suggest that RegenOss is a valid and safe alternative to restoring acetabular bone loss in revision hip arthroplasty.
Collapse
Affiliation(s)
- Pietro Cimatti
- Reconstructive Orthopaedic Surgery and Innovative Techniques—Musculoskeletal Tissue Bank, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy
| | - Isabella Andreoli
- Reconstructive Orthopaedic Surgery and Innovative Techniques—Musculoskeletal Tissue Bank, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy
| | - Maurizio Busacca
- Montecatone Institute Rehabilitation Hospital, 40026 Imola, Italy
| | - Marco Govoni
- Reconstructive Orthopaedic Surgery and Innovative Techniques—Musculoskeletal Tissue Bank, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy
| | - Leonardo Vivarelli
- Reconstructive Orthopaedic Surgery and Innovative Techniques—Musculoskeletal Tissue Bank, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy
| | - Nicolandrea Del Piccolo
- Reconstructive Orthopaedic Surgery and Innovative Techniques—Musculoskeletal Tissue Bank, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy
| | - Alessandra Maso
- Laboratory of Microbiology and GMP Quality Control, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy
| | - Cesare Stagni
- Reconstructive Orthopaedic Surgery and Innovative Techniques—Musculoskeletal Tissue Bank, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy
| | - Giovanni Pignatti
- Rizzoli Sicilia Department, IRCCS Istituto Ortopedico Rizzoli, 90011 Bagheria, Italy
| |
Collapse
|
6
|
Stemmed acetabular cup as a salvage implant for revision total hip arthroplasty with Paprosky type IIIA and IIIB acetabular bone loss. Orthop Traumatol Surg Res 2020; 106:589-596. [PMID: 32265174 DOI: 10.1016/j.otsr.2020.01.012] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/13/2019] [Revised: 01/18/2020] [Accepted: 01/22/2020] [Indexed: 02/03/2023]
Abstract
INTRODUCTION Certain cases of repeated acetabular loosening with severe bone loss are hardly amenable to reconstruction using a Kerboull-type plate with allograft. This limitation is more likely when the severe bone loss occurs in older adults with significant comorbidities that may require a faster procedure. In these indications, a stemmed acetabular cup may be an alternative, although the outcomes have not been well defined, especially for a version where the peg is coated with porous material and additional screws can be added. This led us to conduct a retrospective study to determine: (1) whether a stemmed cup anchored in the iliac isthmus is a viable alternative in these situations, (2) the complication rate and (3) the revision rate for any reason. HYPOTHESIS A stemmed cup anchored in the iliac isthmus is a viable alternative in cases of repeated revision with severe acetabular bone loss. MATERIALS AND METHODS We performed a retrospective single-center study. Sixteen Integra™ cups were implanted in 14 patients (mean age 72.8±10.4 years, minimum-maximum: 58-95) who had aseptic acetabular loosening combined with severe acetabular bone loss graded as Paprosky IIIA in 7 hips and IIIB in 9 hips. The patients had undergone a mean of 2.7±1.8 (minimum-maximum: 1-6) procedures (i.e. primary and/or revision arthroplasty) before this cup was implanted. The cup's survivorship at the time of review and the complication rate were determined. RESULTS At a mean follow-up of 48.8±23.4 months (minimum-maximum: 7-85), two patients had died and two were lost to follow-up. Six hips experienced one or more complications (37.5%): three infections (18.8%), two mechanical failures (12.5%) and one dislocation (6.7%). The cup had to be removed in three patients (18.8%). These complications required reoperation, thus the cumulative incidence of revision for any reason at 5 years was 31% (95% CI: 11-55%). CONCLUSION Despite the high complication and revision rates, we believe the stemmed acetabular cup is a viable alternative in salvage reconstruction procedures. LEVEL OF EVIDENCE IV, Retrospective case study.
Collapse
|