1
|
Regis D, Cason M, Magnan B. Dislocation of primary total hip arthroplasty: Analysis of risk factors and preventive options. World J Orthop 2024; 15:501-511. [PMID: 38947255 PMCID: PMC11212535 DOI: 10.5312/wjo.v15.i6.501] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/31/2023] [Revised: 02/10/2024] [Accepted: 05/27/2024] [Indexed: 06/12/2024] Open
Abstract
Total hip arthroplasty (THA) is one of the most successful elective operations in orthopedic surgery for improving pain and functional disability in patients with end-stage joint disease. However, dislocation continues to be a troublesome complication after THA, as it is a leading cause of revision and is associated with substantial social, health, and economic costs. It is a relatively rare, usually early occurrence that depends on both the patients' characteristics and the surgical aspects. The most recent and important finding is the special attention to be given preoperatively to spinopelvic mobility, which is closely related to the incidence of dislocation. Consequently, clinical and radiographic assessment of the lumbar spine is mandatory to identify an altered pelvic tilt that could suggest a different positioning of the cup. Lumbar spinal fusion is currently considered a risk factor for dislocation and revision regardless of whether it is performed prior to or after THA. Surgical options for its treatment and prevention include the use of prostheses with large diameter of femoral head size, dual mobility constructs, constrained liners, and modular neck stems.
Collapse
Affiliation(s)
- Dario Regis
- Department of Orthopedic and Trauma Surgery, Integrated University Hospital, Verona 37126, Veneto, Italy
| | - Mattia Cason
- Department of Orthopedic and Trauma Surgery, Integrated University Hospital, Verona 37126, Veneto, Italy
| | - Bruno Magnan
- Department of Orthopedic and Trauma Surgery, Integrated University Hospital, Verona 37126, Veneto, Italy
| |
Collapse
|
2
|
Solou K, Panagopoulos A, Tatani I, Megas P. Fracture of femoral neck in modular total hip arthroplasty: a systematic review of the literature. Hip Int 2024; 34:409-420. [PMID: 37932248 DOI: 10.1177/11207000231211253] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2023]
Abstract
BACKGROUND Modular femoral stems have the advantage of anatomic hip reconstruction by restoring the femoral offset thus minimising the bearing surface wear, implant loosening and dislocation. AIM This study aims to investigate the existing literature on modular neck fractures, to identify predisposing factors and guide the decision-making process in the management of these difficult cases. METHODS A systematic literature review was conducted until July 2022. PRISMA guidelines were followed, eligibility criteria were set, and methodology assessment of included studies was conducted based on MINORS criteria, size and primary outcome. Data were extracted and analysed thoroughly. RESULTS 5657 studies were initially screened; the full texts of 124 records were assessed and finally, 32 reports were included. There were 7 clinical studies and 25 case reports. A total of 4825 patients (5204 hips) with a mean age 62.38 years and a mean BMI 29.06 kg/m2 were analysed in the 7 clinical studies. The reported overall weighted revision rate was 0.86%, while the weighted mean modular neck fracture rate was 0.26%. The usual history was sudden experience of hip pain and instability. The average time interval to neck fracture was 4.57 (range 3-4.7) years and a long modular neck was identified in 91.17% of them. Data from case reports showed a mean age and average BMI of 55.85 and 31.63 kg/m2. 82.35% of the patients were male. Necks were fractured after an average time interval of 64.5 ± 8.8 months. CONCLUSIONS The incidence of modular neck fracture is significant. The profile of a male, obese patient with a long modular neck increased risk of neck fracture. Microstructural investigation of the retrieved implants demonstrated a higher incidence of fracture line in the base of the neck junction and at its anterolateral distal part. Surgeons should be aware of this complication while using or revising such protheses.
Collapse
Affiliation(s)
| | - Andreas Panagopoulos
- Faculty of Medicine, Patras University, Patra, Greece
- Orthopaedic Department, Patras General University Hospital, Patras, Greece
| | - Irini Tatani
- Faculty of Medicine, Patras University, Patra, Greece
- Orthopaedic Department, Patras General University Hospital, Patras, Greece
| | - Panagiotis Megas
- Faculty of Medicine, Patras University, Patra, Greece
- Orthopaedic Department, Patras General University Hospital, Patras, Greece
| |
Collapse
|
3
|
Shigemura T, Kamikawa K, Yamamoto Y, Murata Y. Sex-based differences in neck selectivity in total hip arthroplasty using a modular femoral neck system. Int J Artif Organs 2024; 47:290-298. [PMID: 38584296 DOI: 10.1177/03913988241243021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/09/2024]
Abstract
BACKGROUND Dislocation is a major complication of total hip arthroplasty (THA). The modular femoral neck system provides practical advantages by allowing adjustment of neck version and length in the presence of intraoperative instability. Anatomical studies have identified morphological differences in the hip joint between men and women. Despite sex-based differences in hip morphology, it remains unclear whether such differences affect neck selectivity in THA using a modular neck system and whether this approach achieves anatomical reconstruction, thereby reducing complications such as dislocation. This study aimed to investigate gender differences in neck selectivity in THA with the modular neck system and assess the clinical impact of the modular neck system. METHODS A total of 163 THAs using a modular neck system were included in this study. Data on the type of modular neck and intraoperative range of motion (ROM) were retrieved from patient records. Pre- and post-operative leg length differences (LLD) were examined as part of the radiographic assessment. Dislocation was investigated as a postoperative complication. RESULTS Neck selectivity did not significantly differ between men and women. The comparison of pre- and post-operative LLD revealed a tendency for varus necks to improve LLD more than version-controlled necks. Furthermore, no significant correlation was found between intraoperative ROM and neck selectivity, or postoperative dislocation and neck selectivity. CONCLUSIONS This study on THA with a modular neck system provided valuable insights into sex-based differences in neck selectivity and highlighted the potential benefits of the modular neck system in addressing LLD and preventing postoperative dislocation.
Collapse
|
4
|
Ciatti C, Maniscalco P, Bosio S, Puma Pagliarello C, Bianchi G, Quattrini F. Pseudotumor from ceramic-on-ceramic total hip arthroplasty. Int J Surg Case Rep 2024; 116:109374. [PMID: 38401324 PMCID: PMC10943669 DOI: 10.1016/j.ijscr.2024.109374] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2023] [Revised: 02/05/2024] [Accepted: 02/07/2024] [Indexed: 02/26/2024] Open
Abstract
INTRODUCTION AND IMPORTANCE Total hip arthroplasty is one of the most performed surgical interventions in the world. Adverse local tissue reactions and pseudotumors are infrequent but dangerous eventualities, which are often related with metal-on-metal or metal-on-polyethylene implants. This study wants to highlight how adverse local tissue reactions and pseudotumors must be taken into consideration during the diagnostic process. CASE PRESENTATION We report the case of a patient with ceramic-on-ceramic modular total hip arthroplasty with titanium neck. 12 years after surgery, he complained of pain and swelling on the hip. Diagnostic tests revealed the presence of a bulky pseudotumor. During the revision surgery biopsy samples were taken and microscopical analysis revealed the presence of fibrous tissue, fibrin hemorrhagic collections, histiocytes and chronic inflammation due to foreign body, with dark refractive material of an exogenous nature. CLINICAL DISCUSSION The possible formation of pseudotumor and metallosis reactions in hip prostheses with metal-on-metal coupling or in couplings with polyethylene is known. Many cases of pseudotumor are reported after revision of prostheses due to the breakage of ceramic components, but we did not observe any damage or corrosion of the prosthetic elements; on the other hand, we noticed an excessive retroversion of the femoral neck. It may be possible that an accurate microscopic analysis could clarify the failure of this implant. CONCLUSION To date ceramic-ceramic coupling remains the gold standard in terms of resistance and durability for hip arthroplasty but there is still a gap of knowledge in the field of tribology and individual immune response mechanisms.
Collapse
Affiliation(s)
- Corrado Ciatti
- U.O.C. Orthopedics and Traumatology, Guglielmo Da Saliceto Hospital, AUSL Piacenza, Italy; University of Parma
| | - Pietro Maniscalco
- U.O.C. Orthopedics and Traumatology, Guglielmo Da Saliceto Hospital, AUSL Piacenza, Italy; University of Parma.
| | - Silvia Bosio
- Pathology Unit, Onco-Hematologic Department, Guglielmo Da Saliceto Hospital, AUSL Piacenza, Piacenza, Italy
| | | | - Giuseppe Bianchi
- Clinica Ortopedica III, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Fabrizio Quattrini
- U.O.C. Orthopedics and Traumatology, Guglielmo Da Saliceto Hospital, AUSL Piacenza, Italy; University of Parma
| |
Collapse
|
5
|
Castagnini F, Bordini B, Cosentino M, Tassinari E, Guizzardi G, Traina F. Comparison of single taper and dual taper versions of the same stem design in total hip arthroplasty for primary osteoarthritis. J Orthop Traumatol 2023; 24:5. [PMID: 36725766 PMCID: PMC9892395 DOI: 10.1186/s10195-023-00687-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/30/2022] [Accepted: 01/21/2023] [Indexed: 02/03/2023] Open
Abstract
BACKGROUND In total hip arthroplasty (THA), the outcomes of single taper (ST) and dual taper (DT) versions of the same stem design have been scarcely studied. A registry study comparing ST and DT versions of the same stem design was designed, aiming to assess: (1) the survival rates and the hazard ratios for failure; (2) the survival rates and the hazard ratios for failure using stem-focused endpoints. MATERIAL AND METHODS A regional arthroplasty registry was interrogated about stem designs with ST and DT versions in cementless THAs performed for primary osteoarthritis. Only the same cup and ceramic-on-ceramic bearings were included: the DT stems had a titanium-on-titanium modularity. Demographic and implant features were recorded. Survival rates and hazard ratios were evaluated and compared. Stem-focused endpoints were also investigated. RESULTS A total of 5359 THAs were included, with three stem designs. The two versions of every stem showed different demographics and implant-related features: ST versions were preferentially implanted in heavier young men. For each stem, the two versions had similar survival rates at 5 years (p = 0.076; p = 0.319; p = 0.616) and similar adjusted hazard ratios for failures (p = 0.084; p = 0.308; p = 0.729). When stem-focused endpoints were adopted, the ST and DT versions of the three stems achieved similar survival rates (p = 0.710; p = 0.784; p = 0.983) and similar adjusted hazard ratios (p = 0.647; p = 0.858; p = 0.787). Three neck breakages occurred (0.0007% of all the modular implants). CONCLUSIONS ST and DT versions of the same stem design did not show any differences in terms of survival rates and hazard ratios for failures at 5 years. LEVEL OF EVIDENCE IV.
Collapse
Affiliation(s)
- Francesco Castagnini
- grid.419038.70000 0001 2154 6641Ortopedia-Traumatologia e Chirurgia Protesica e Dei Reimpianti d’anca E Di Ginocchio, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136 Bologna, Italy
| | - Barbara Bordini
- grid.419038.70000 0001 2154 6641Laboratorio Di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, Via Di Barbiano 1/10, 40136 Bologna, Italy
| | - Monica Cosentino
- grid.419038.70000 0001 2154 6641Ortopedia-Traumatologia e Chirurgia Protesica e Dei Reimpianti d’anca E Di Ginocchio, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136 Bologna, Italy
| | - Enrico Tassinari
- grid.419038.70000 0001 2154 6641Ortopedia-Traumatologia e Chirurgia Protesica e Dei Reimpianti d’anca E Di Ginocchio, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136 Bologna, Italy
| | - Giulia Guizzardi
- grid.419038.70000 0001 2154 6641Ortopedia-Traumatologia e Chirurgia Protesica e Dei Reimpianti d’anca E Di Ginocchio, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136 Bologna, Italy
| | - Francesco Traina
- grid.419038.70000 0001 2154 6641Ortopedia-Traumatologia e Chirurgia Protesica e Dei Reimpianti d’anca E Di Ginocchio, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136 Bologna, Italy ,grid.6292.f0000 0004 1757 1758DIBINEM, Università Di Bologna, Bologna, Italy
| |
Collapse
|
6
|
Castagnini F, Cosentino M, Bordini B, Montalti M, Biondi F, Faldini C, Traina F. Titanium modular stems in total hip arthroplasty due to developmental dysplasia: a registry comparison with single-taper implants. Hip Int 2023; 33:916-924. [PMID: 36127850 PMCID: PMC10486160 DOI: 10.1177/11207000221124115] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/04/2021] [Accepted: 06/28/2022] [Indexed: 02/04/2023]
Abstract
INTRODUCTION The routine use of proximal femoral modularity was discouraged in total hip arthroplasties (THAs). However, titanium dual-taper (DT) implants may provide some advantages over single-taper (ST) stems in cases of complex deformity. A registry study comparing ST and DT stems in dysplasia was designed, aiming to assess: (1) survival rates at long-term; (2) reasons for revision; (3) the profile of failed implants. METHODS The arthroplasty registry RIPO was investigated for cementless THAs performed for dysplasia since 2000. ST implants were compared to titanium-on-titanium DT stems. Demographics and implant features were collected. Survival rates and reasons for revision were compared. The profile of DT stem failures in dysplasia was defined. RESULTS 6429 implants were included in the study, 3642 ST and 2787 DT. The demographic and implant features of the 2 cohorts were not comparable. The DT cohort achieved higher survival rates at long-term (93.9% vs. 91.6%, p = 0.018). DT implants showed a higher rate of implant breakage (0.6%, p = 0.011) and a lower rate of aseptic loosening (p = 0.005). There were no differences in terms of revisions for dislocation. No metallosis occurred. There were more revisions in DT implants in males <65 years, with a 28-mm head size or smaller. CONCLUSIONS Modularity did not result in lower survival rates in dysplastic patients and may even reduce the rate of aseptic loosening in comparison to ST stems. The rate of implant breakage is not negligible. Younger males are not good candidates for titanium DT stems.
Collapse
Affiliation(s)
- Francesco Castagnini
- Orthopaedic-Traumatology and Prosthetic Surgery and Revisions of Hip and Knee Implants, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Monica Cosentino
- Medical Technology Laboratory, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Barbara Bordini
- Medical Technology Laboratory, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Maurizio Montalti
- Orthopaedic-Traumatology and Prosthetic Surgery and Revisions of Hip and Knee Implants, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Federico Biondi
- Orthopaedic-Traumatology and Prosthetic Surgery and Revisions of Hip and Knee Implants, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Cesare Faldini
- First Orthopaedic and Traumatology Clinic, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
- University of Bologna, Italy
| | - Francesco Traina
- Orthopaedic-Traumatology and Prosthetic Surgery and Revisions of Hip and Knee Implants, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
- University of Bologna, Italy
| |
Collapse
|
7
|
Zajc J, Fokter SK. Bimodular femoral stems in primary total hip arthroplasty. Expert Rev Med Devices 2023; 20:1051-1064. [PMID: 37753590 DOI: 10.1080/17434440.2023.2264177] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Accepted: 09/25/2023] [Indexed: 09/28/2023]
Abstract
INTRODUCTION This review critically examines the efficacy of dual-modular stems in primary total hip arthroplasty. Given the variability and non-comparability of certain femoral stem designs and stem-neck couplings, with some even being withdrawn from the market, this review offers an in-depth analysis of predominant implant performances. AREAS COVERED The paper explores a brief historical summary related to dual-modular stems, including the complications associated with their use, diagnostic tools for evaluation, analysis of both recalled and currently available models, as well as alternative therapeutic options. This information is pertinent for both clinical and research domains. EXPERT OPINION While dual-modular systems were initially touted to offer several advantages, the evidence substantiating these benefits has been ambiguous. Further, these systems introduce the risk of alternative complications. In specific cases involving patients with developmental hip dysplasia and certain proximal femoral deformities requiring complex reconstructions, dual-modular systems might be relevant. Nonetheless, the use of long interchangeable necks in patients with a body mass index above 30 kg/m2 is discouraged, and pairing a long varus-oriented neck with an extra-long femoral head should be avoided in all patients.
Collapse
Affiliation(s)
- Jan Zajc
- Clinical Department of Orthopedic Surgery, University Medical Center Maribor, Maribor, Slovenia
- Faculty of Medicine, University of Maribor, Maribor, Slovenia
| | - Samo K Fokter
- Clinical Department of Orthopedic Surgery, University Medical Center Maribor, Maribor, Slovenia
- Faculty of Medicine, University of Maribor, Maribor, Slovenia
| |
Collapse
|
8
|
Dual-Modular Versus Single-Modular Stems for Primary Total Hip Arthroplasty: A Long-Term Survival Analysis. MEDICINA (KAUNAS, LITHUANIA) 2023; 59:medicina59020290. [PMID: 36837491 PMCID: PMC9964070 DOI: 10.3390/medicina59020290] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Revised: 01/24/2023] [Accepted: 01/31/2023] [Indexed: 02/05/2023]
Abstract
Background and Objectives: Increased revision rate of dual-modular (DM) femoral stems in primary total hip arthroplasty (THA) because of modular-neck breakage and adverse local tissue reactions (ALTRs) to additional junction damage products is well established and some designs have been recalled from the market. However, some long-term studies of specific DM stems did not confirm the inferiority of these stems compared to standard single-modular (SM) stems, and a head-to-head comparison THA is missing. The objectives of this multicentre study were to determine the survivorship and complication rates of a common DM stem design compared to a similar SM stem. Materials and Methods: In a time frame from January 2012 to November 2015, a cohort of 807 patients (882 hips) consecutively underwent primary cementless THAs at two orthopaedic centres. 377 hips were treated with a Zweimüller-type DM stem THA system and 505 hips with a similar SM stem THA system, both including a modern press-fit acetabulum. Kaplan-Meier survivorship and complication rates were compared between both groups in a median follow-up of 9.0 years (maximum, 9.9 years). Results: The 9-year survivorship of the DM stem THA system (92.6%, 95% CI 89.9-95.3) was significantly lower than that of the SM stem THA system (97.0%, 95% CI 95.2-98.8). There were no differences in revision rates for septic loosening, dislocation, and periprosthetic fractures between the two groups. One ceramic inlay and one Ti-alloy modular neck breakage occurred in the DM stem THA system group, but the main reason for revision in this group was aseptic loosening of components. Conclusions: The survivorship of the DM stem THA system was lower than the similar SM stem THA system in a comparable clinical environment with long-term follow-up. Our results confirmed that no rationale for stem modularity exists in primary THAs.
Collapse
|
9
|
Long-term survivorship of an exchangeable-neck hip prosthesis with a Ti-alloy/Ti-alloy neck-stem junction. Arch Orthop Trauma Surg 2022; 143:3649-3657. [PMID: 36178493 DOI: 10.1007/s00402-022-04634-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/27/2021] [Accepted: 09/18/2022] [Indexed: 11/02/2022]
Abstract
INTRODUCTION Breakage of exchangeable-neck (EN) and adverse local tissue reactions (ALTRs) to neck-stem junction (NSJ) damage products are responsible for increasing the revision rate of EN hip prostheses. We investigated the survivorship of an EN hip prosthesis including a NSJ with both components made of titanium alloy (Ti-alloy/Ti-alloy) to assess whether, and to what extent, EN breakage and NSJ damage affected implant survivorship. MATERIALS AND METHODS Using data from a hip replacement registry, we determined survivorship of 2857 EN prostheses. Long-offset configurations of head and EN were implanted in heavy (> 90 kg) patients only in 23 hips. We investigated under which conditions EN breakages or ALTRs occurred. We also measured titanium (Ti) and vanadium (V) blood concentrations in 24 patients with a unilateral well-working prosthesis. RESULTS The 17-year survival rates for any reason and aseptic loosening of any component were 88.9% (95%CI 87.5-90.1; 857 hips at risk) and 96.9% (95%CI 96.0-97.6), respectively. There were two cases of EN breakage and one case of ALTR (metallosis), due to rim-neck impingement, out of 276 revisions. After an average period of 9.8 years (range 7.8-12.8 years), the maximum Ti and V blood concentrations in patients with a well-working prosthesis were 5.0 µg/l and 0.16 µg/l, respectively. CONCLUSION The present incidence of EN breakage or ALTR is lower than those reported in other studies evaluating EN hip prosthesis survivorship. This study suggests that (i) the risk of EN breakage is reduced by limiting the use of long-offset configurations in heavy patients and (ii) Ti-alloy/Ti-alloy NSJ damage products do not promote ALTR nor significantly alter the rate of implant loosening. Since design decisions and implant configuration determine the NSJ strength, the NSJ strength in working conditions must be thoroughly investigated to proper define the clinical indications for any EN design.
Collapse
|
10
|
Solarino G, Vicenti G, Carrozzo M, Ottaviani G, Moretti B, Zagra L. Modular neck stems in total hip arthroplasty: current concepts. EFORT Open Rev 2021; 6:751-758. [PMID: 34667646 PMCID: PMC8489472 DOI: 10.1302/2058-5241.6.200064] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Modular neck (MN) implants can restore the anatomy, especially in deformed hips such as sequelae of development dysplasia. Early designs for MN implants had problems with neck fractures and adverse local tissue, so their use was restricted to limited indications. Results of the latest generation of MN prostheses seem to demonstrate that these problems have been at least mitigated. Given the results of the studies presented in this review, surgeons might consider MN total hip arthroplasty (THA) for a narrower patient selection when a complex reconstruction is required. Long MN THA should be avoided in case of body mass index > 30, and should be used with extreme caution in association with high offset femoral necks with long or extra-long heads. Cr-Co necks should be abandoned, in favour of a titanium alloy connection. Restoring the correct anatomic femoral offset remains a challenge in THA surgeries. MN implants have been introduced to try to solve this problem. The MN design allows surgeons to choose the appropriate degree and length of the neck for desired stability and range of motion.
Cite this article: EFORT Open Rev 2021;6:751-758. DOI: 10.1302/2058-5241.6.200064
Collapse
Affiliation(s)
- Giuseppe Solarino
- Department of Neuroscience and Organs of Sense, Orthopaedics Section, Faculty of Medicine and Surgery, University of Bari, Bari, Italy
| | - Giovanni Vicenti
- Department of Neuroscience and Organs of Sense, Orthopaedics Section, Faculty of Medicine and Surgery, University of Bari, Bari, Italy
| | - Massimiliano Carrozzo
- Department of Neuroscience and Organs of Sense, Orthopaedics Section, Faculty of Medicine and Surgery, University of Bari, Bari, Italy
| | - Guglielmo Ottaviani
- Department of Neuroscience and Organs of Sense, Orthopaedics Section, Faculty of Medicine and Surgery, University of Bari, Bari, Italy
| | - Biagio Moretti
- Department of Neuroscience and Organs of Sense, Orthopaedics Section, Faculty of Medicine and Surgery, University of Bari, Bari, Italy
| | - Luigi Zagra
- IRCCS Istituto Ortopedico Galeazzi, Hip Department, Milan, Italy
| |
Collapse
|
11
|
Lex JR, Welch MD, See A, Edwards TC, Stavropoulos NA, Babis GC. Systematic review of primary total hip arthroplasty using titanium-titanium modular-neck prostheses: the true risk of revision. Hip Int 2021; 31:295-303. [PMID: 32297561 DOI: 10.1177/1120700020916870] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
AIMS Modular-neck femoral implants are used to enable more variability in femoral neck version, offset and length. It has been reported that these implants carry a higher rate of revision. The aim of this review was to assess the overall and cause-specific revision rate of titanium-titanium alloy modular-neck implants in primary total hip arthroplasty (THA). METHODS A systematic review was conducted following PRISMA guidelines and utilising multiple databases. All results were screened for eligibility. Studies published from 2000 onwards, using a current-generation, titanium-titanium, modular-neck implant were included. Overall and cause-specific revision rates were analysed, comparing to fixed-neck prostheses where applicable. RESULTS 920 studies were screened. After applying exclusion criteria, 23 were assessed in full and 14 included. These consisted of 12 case series and 2 joint registry analyses. 21,841 patients underwent a modular-neck implant with a weighted mean follow-up of 5.7 years, mean age of 62.4 years, and average body mass index (BMI) of 28.4kg/m2. The overall revision rate was 3.95% and 2.98% for modular and fixed-neck prostheses, respectively. For studies with >5 years follow-up the mean revision rate was 3.08%. There was no difference in cause-specific revision rates by implant design. Mean improvement in Harris Hip Score was 41.9. CONCLUSIONS At medium-term, revision rates for titanium-titanium primary modular-neck THA are acceptable. These prostheses are a sensible management option in patients with considerable anatomical hip deformity not amenable to correction with standard fixed-neck implants. Patients of male gender, high BMI and requiring prostheses with a larger neck, offset or head are at higher risk of implant failure.
Collapse
Affiliation(s)
- Johnathan R Lex
- Oxford Foundation School, Oxford, UK.,Royal Orthopaedic Hospital, Birmingham, UK
| | - Matthew D Welch
- Oxford Foundation School, Oxford, UK.,Oxford University Clinical Academic Graduate School, Oxford, UK
| | - Abbas See
- Oxford Foundation School, Oxford, UK
| | | | - Nikolaos A Stavropoulos
- 2nd Department of Orthopaedic Surgery, Konstantopouleio General Hospital, National and Kapodistrian University of Athens, Athens Medical School, Athens, Greece.,Department of Orthopaedic Surgery, General Hospital of Karpenissi, Karpenissi, Greece
| | - George C Babis
- 2 Department of Orthopaedic Surgery, Konstantopouleio General Hospital, National and Kapodistrian University of Athens, Athens Medical School, Athens, Greece
| |
Collapse
|
12
|
Beauchamp JE, Vendittoli PA, Barry J, Pelet S, Belzile EL. Catastrophic failure of femoral stem modular junction when combined with metal-on-metal bearing in comparison to ceramic-on-ceramic: A retrospective cohort study. Orthop Traumatol Surg Res 2021; 107:102749. [PMID: 33316446 DOI: 10.1016/j.otsr.2020.102749] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/29/2020] [Revised: 08/06/2020] [Accepted: 08/17/2020] [Indexed: 02/03/2023]
Abstract
BACKGROUND Metal ion release from total hip arthroplasty's (THA) metal-on-metal (MoM) bearing surfaces or head-neck modular junction (trunnionosis) has been identified as a major cause of adverse reaction to metal debris (ARMD). No study has compared the effects of these bearing couples when combined with modular neck femoral stems (MNFS) (i.e. did a modular CoCr have a higher effect than large MoM bearings on whole blood ion concentrations and ARMD). Therefore we did a retrospective comparative analysis of prospectively collected data aiming to: (1) assess the difference in metal ion release between a group of MoM and CoC bearings implanted with a non-cemented MNFS; (2) compare the ARMD and the related revision rates between the two bearing types; (3) compare the patients' HOOS and Harris Hip scores. HYPOTHESIS Metal ion levels and complications rate will be higher in MoM group. METHODS Thirty hips received the same short MNFS with modular CoCr. Seventeen had CoC bearing (16=36mm) and 13 large diameter head (LDH) MoM bearing (mean=50mm, 44-54mm) Both groups had whole blood Cobalt (Co) and Chromium (Cr) concentrations measurements at last follow up or before revision surgery (if any) and were compared to 41 control individuals without implants. ARMD, revision rates and other complications were censed. Functional outcome differences between operative groups were assessed with HOOS and Harris Hip scores. RESULTS Mean whole blood Co and Cr were 1.9μg/L (0.1-10.6 min-max) and 1.2μg/L (0.2-4.6 min-max) in the CoC group and 12.7μg/L (2.5-40.7 min-max) and 8.2μg/L (2.8-40.6 min-max) for MoM group. Controls presented whole blood Co and Cr levels of 0.2μg/L (0.04-0.2 min-max) and 0.6μg/L (0.1-0.7 min-max) respectively. CoC had significantly higher whole blood metal ion concentrations than controls, while MoM had significantly higher concentrations than both (p<0.001). MoM had a 9/13 (69%) revision rate due to ARMD (with stem-neck junction corrosion and wear were present in all cases) while the CoC had none. Functional scores at last follow up did not statistically differ between groups (Harris: CoC=94.1±8.4 vs MoM 91.8±14.8 (p=0.22) and CoC HOOS 90.2±10.7 vs 75.6±21.7 (p=0.08)). CONCLUSION In our study, MNFS with CoCr modular neck released metal ion systemically, as shown in CoC THAs, but when combined with MoM LDH bearings, that elevation was significantly higher. In MNFS MoM, these high metal ion levels translated into a dramatic ARMD related revision rate where stem-neck junction corrosion and wear were present in all cases. More research is required to understand the effects of MoM bearing on neck-stem junctions, and its mechanisms of corrosion. LEVEL OF EVIDENCE III; retrospective comparative study.
Collapse
Affiliation(s)
- Jean-Etienne Beauchamp
- Division of Orthopaedic Surgery, Department of Surgery, Faculty of Medicine, Université Laval (G1V 0A6), Quebec, QC, Canada.
| | - Pascal-André Vendittoli
- Department of Surgery, Montreal University, CIUSSS-de-L'Est-de-L'Ile-de-Montréal, Hôpital Maisonneuve-Rosemont (H1T 2M4), 5415 Boulevard L'Assomption, Montreal, QC, Canada
| | - Janie Barry
- Department of Surgery, Montreal University, CIUSSS-de-L'Est-de-L'Ile-de-Montréal, Hôpital Maisonneuve-Rosemont (H1T 2M4), 5415 Boulevard L'Assomption, Montreal, QC, Canada
| | - Stéphane Pelet
- Division of Orthopaedic Surgery, Department of Surgery, Faculty of Medicine, Université Laval (G1V 0A6), Quebec, QC, Canada; Division of Orthopaedic Surgery, CHU de Québec-Université Laval (G1J 1Z4), 1401, 18e rue, Quebec, QC, Canada
| | - Etienne L Belzile
- Division of Orthopaedic Surgery, Department of Surgery, Faculty of Medicine, Université Laval (G1V 0A6), Quebec, QC, Canada; Division of Orthopaedic Surgery, CHU de Québec-Université Laval (G1J 1Z4), 1401, 18e rue, Quebec, QC, Canada
| |
Collapse
|
13
|
Incidence of Pseudotumors in a Dual Modular Stem Construct With and Without Metal-on-Metal Bearing Surface. J Am Acad Orthop Surg 2021; 29:e92-e97. [PMID: 32568995 DOI: 10.5435/jaaos-d-19-00652] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The purpose of this study was to compare the incidence of pseudotumors in metal-on-metal (MoM) titanium modular neck hip arthroplasties to non-MoM modular neck hip arthroplasties. A secondary goal was to determine whether a correlation exists between elevated metal concentrations and pseudotumor incidence. METHODS The data were collected and evaluated from 49 MoM joints and 26 non-MoM joints between the years 2012 and 2017. Hip ultrasonography was done after a minimum of 5 years postimplantation. Whole serum metal (titanium, cobalt, and chromium) concentrations were measured at the hip ultrasonography study. RESULTS The average time elapsed between surgery and ultrasonography visit was 7.6 years. In the 49 patients with MoM joints, 22.4% (n = 11) had a pseudotumor. In the 26 patients with non-MoM joints, 9.1% of metal-on-polyethylene hips (n = 1) and 0% of ceramic-on-ceramic/polyethylene hips developed a pseudotumor. No significant statistical correlation was observed between serum metal concentrations and pseudotumor formation (P > 0.05). A significant correlation was observed of serum titanium concentration to pseudotumor size (P = 0.024). CONCLUSION The incidence of pseudotumor formation in MoM total hip arthroplasties was more than five times the incidence associated with non-MoM bearings. The correlation between serum titanium concentration and pseudotumor size suggests that titanium levels may be a useful indicator for pseudotumor formation in patients with this particular titanium modular neck femoral implant. No notable correlation was observed between serum cobalt and chromium concentration and pseudotumor formation or size.
Collapse
|
14
|
Maniscalco P, Quattrini F, Ciatti C, Ghidoni L, Ghidoni G, Burgio V, Pogliacomi F, Vaienti E, Ceccarelli F. Neck modularity in total hip arthroplasty: a retrospective study of nine hundred twenty-eight titanium neck implants with a maximum follow-up of eighteen years. INTERNATIONAL ORTHOPAEDICS 2020; 44:2261-2266. [PMID: 32601721 DOI: 10.1007/s00264-020-04686-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2020] [Accepted: 06/23/2020] [Indexed: 11/24/2022]
Abstract
PURPOSE Neck modularity was introduced to improve total hip arthroplasty (THA) accuracy, but it has been associated with early breakages and corrosion issues. In our hospital, modular necks have been in clinical use since the 1990s. We retrospectively analysed the occurrence of these sequelae in implants placed between January 2000 and December 2014. METHODS Survival data from patients operated on in our hospital were obtained from the regional arthroplasty registry (Registro dell'Impiantologia Protesica Ortopedica, RIPO). The cohort comprised 928 THAs on 908 patients. The average patient age was 67.8 years. Main indications were primary osteoarthritis (71.4%), fracture (9.2%), congenital dysplasia or congenital luxation (7.8%), and idiopathic osteonecrosis (6.4%). All femoral stems were cementless, with 318 anatomically shaped (34.3%), 579 straight (62.4%), and 31 short stems (3.3%). All necks used were made of titanium alloy. The average follow-up time was 9.6 years (range, 4-18 years). RESULTS In total, 66 revisions were reported. The main revision causes were periprosthetic fractures (33.3%), aseptic stem loosening (19.7%), luxation (18.2%), and implant breakage (12.1%). Five modular neck breakages were recorded. The overall survival rate was 87.7% at 17 years. We did not observe any component corrosion. The neck breakage rate was 0.5%, and the luxation rate was 1.3%. CONCLUSIONS Our experience suggests that neck modularity is a safe, effective way to reconstruct the proximal femur in THA patients. We attribute the absence of corrosion to the exclusive use of titanium necks.
Collapse
Affiliation(s)
- Pietro Maniscalco
- Guglielmo da Saliceto Hospital, Via Taverna 49, 29121, Piacenza, Italy
| | | | - Corrado Ciatti
- Guglielmo da Saliceto Hospital, Via Taverna 49, 29121, Piacenza, Italy.
| | - Laura Ghidoni
- Guglielmo da Saliceto Hospital, Via Taverna 49, 29121, Piacenza, Italy
| | - Giuseppe Ghidoni
- Guglielmo da Saliceto Hospital, Via Taverna 49, 29121, Piacenza, Italy
| | - Valeria Burgio
- Guglielmo da Saliceto Hospital, Via Taverna 49, 29121, Piacenza, Italy
| | | | | | | |
Collapse
|
15
|
Frandsen J, Duensing I, Anderson L, Gililland J. Disassociation of a Cold-Welded Bimodular Titanium Femoral Stem by Intraoperative Ice Cooling. Arthroplast Today 2020; 6:457-462. [PMID: 32637516 PMCID: PMC7329910 DOI: 10.1016/j.artd.2020.05.018] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/21/2020] [Revised: 05/15/2020] [Accepted: 05/21/2020] [Indexed: 11/24/2022] Open
Abstract
Modularity in total hip arthroplasty allows a surgeon to have intraoperative versatility, allowing for fine adjustments of the femoral offset, leg length, and version. However, modularity can be a source of multiple complications. This case report describes a novel intraoperative solution for the problem of cold welding of a neck-stem junction using sterile ice to cryogenically disengage the modular components.
Collapse
Affiliation(s)
- Jeff Frandsen
- Department of Orthopaedics, University of Utah Hospital, Salt Lake City, UT, USA
| | - Ian Duensing
- Department of Orthopaedics, University of Utah Hospital, Salt Lake City, UT, USA
| | - Lucas Anderson
- Department of Orthopaedics, University of Utah Hospital, Salt Lake City, UT, USA
| | - Jeremy Gililland
- Department of Orthopaedics, University of Utah Hospital, Salt Lake City, UT, USA
| |
Collapse
|
16
|
Mertl P, Dehl M. Femoral stem modularity. Orthop Traumatol Surg Res 2020; 106:S35-S42. [PMID: 31624033 DOI: 10.1016/j.otsr.2019.05.019] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/26/2019] [Revised: 05/08/2019] [Accepted: 05/13/2019] [Indexed: 02/02/2023]
Abstract
Femoral stem modularity in hip replacement was first developed to connect a ceramic head to the stem, then extended to metal heads using the Morse taper principle. Is it a good thing, or a necessary evil? It contributes to improving lower limb length and lateralization setting, at the cost of fairly rare complications such as dissociation and fretting corrosion, which can exceptionally lead to ARMD (Adverse Reaction to Metal Debris). Modular necks were later recommended, with a double Morse taper: cylindrical for the head junction, and more or less flattened for the stem. Is this one modularity too far? Dual modularity in theory perfectly reproduces the biomechanical parameters of the hip, but is unfortunately associated with fractures and severe corrosion, leading to ARMD and pseudotumor, especially in Cr-Co necks. Moreover, it provides no functional advantage, and no longer has a role outside dysplasia and other femoral deformities. Metaphyseal-diaphyseal modularity is not widespread in primary implants, and is it really necessary? Only one model has been widely studied: S-Rom™ (Depuy®). It features a metaphyseal sleeve adapting to the anatomy of the proximal femur, with a stem fitted via an inverse Morse taper. Its only interest is in case of congenital dislocation; like all metal connections, it incurs a risk of fracture and corrosion. On the other hand, modularity is widely employed in revision implants. Does it really help these procedures? The connection between a proximal femoral component of variable geometry and a diaphyseal stem with press-fit distal fixation provides a real solution to problems of length, lateralization and anteversion. Early models encountered high rates of fracture, but current implants and rigorous surgical technique have reduced this risk. Corrosion is a less serious problem, as the Morse taper undergoes only axial stress, without the friction undergone by other models subject to varus stress.
Collapse
Affiliation(s)
- Patrice Mertl
- Service d'orthopédie-traumatologie, CHU d'Amiens, Site Sud, 80054 Amiens Cedex, France.
| | - Massinissa Dehl
- Service d'orthopédie-traumatologie, CHU d'Amiens, Site Sud, 80054 Amiens Cedex, France
| |
Collapse
|
17
|
Kovač S, Mavčič B, Kotnik M, Levašič V, Sirše M, Fokter SK. What Factors Are Associated With Neck Fracture in One Commonly Used Bimodular THA Design? A Multicenter, Nationwide Study in Slovenia. Clin Orthop Relat Res 2019; 477:1324-1332. [PMID: 31136429 PMCID: PMC6554145 DOI: 10.1097/corr.0000000000000646] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/08/2018] [Accepted: 01/04/2019] [Indexed: 01/31/2023]
Abstract
BACKGROUND Femoral stems with bimodular (head-neck as well as neck-body) junctions were designed to help surgeons address patients' hip anatomy individually. However, arthroplasty registers have reported higher revision rates in stems with bimodular junctions than in stems with modularity limited to the head-neck trunnion. However, to our knowledge, no epidemiologic study has identified patient-specific risk factors for modular femoral neck fractures, and some stems using these designs still are produced and marketed. QUESTIONS/PURPOSES The purposes of this study were (1) to establish the survival rate free from aseptic loosening of one widely used bimodular THA design; (2) to define the proportion of patients who experienced a fracture of the stem's modular femoral neck; and (3) to determine factors associated with neck fracture. METHODS In this retrospective, nationwide, multicenter study, we reviewed 2767 bimodular Profemur® Z stems from four hospitals in Slovenia with a mean followup of 8 years (range, 3 days to 15 years). Between 2002 and 2015, the four participating hospitals performed 26,132 primary THAs; this implant was used in 2767 of them (11%). The general indications for using this implant were primary osteoarthritis (OA) in 2198 (79%) hips and other indications in 569 (21%) hips. We followed patients from the date of the index operation to the date of death, date of revision, or the end of followup on March 1, 2018. We believe that all revisions would be captured in our sample, except for patients who may have emigrated outside the country, but the proportion of people immigrating to Slovenia is higher than the proportion of those emigrating from it; however, no formal accounting for loss to followup is possible in a study of this design. There were 1438 (52%) stems implanted in female and 1329 (48%) in male patients, respectively. A titanium alloy neck was used in 2489 hips (90%) and a cobalt-chromium neck in 278 (10%) hips. The mean body mass index (BMI) at the time of operation was 29 kg/m (SD ± 5 kg/m). We used Kaplan-Meier analysis to establish survival rates, and we performed a chart review to determine the proportion of patients who experienced femoral neck fractures. A binary logistic regression model that controlled for the potential confounding variables of age, sex, BMI, time since implantation, type of bearing, diagnosis, hospital, neck length, and neck material was used to analyze neck fractures. RESULTS There were 55 (2%) aseptic stem revisions. Survival rate free from aseptic loosening at 12 years was 97% (95% confidence interval [CI] ± 1%). Fracture of the modular neck occurred in 23 patients (0.83%) with a mean BMI of 29 kg/m (SD ± 4 kg/m.) Twenty patients with neck fractures were males and 19 of 23 fractured necks were long. Time since implantation (odds ratio [OR], 0.55; 95% CI 0.46-0.66; p < 0.001), a long neck (OR, 6.77; 95% CI, 2.1-22.2; p = 0.002), a cobalt-chromium alloy neck (OR, 5.7; 95% CI, 1.6-21.1; p = 0.008), younger age (OR, 0.91; 95% CI, 0.86-0.96; p < 0.001), and male sex (OR, 3.98; 95% CI, 1.04-14.55; p = 0.043) were factors associated with neck fracture. CONCLUSIONS The loosening and neck fracture rates of the Profemur® Z stem were lower than in some of previously published series. However, the use of modular femoral necks in primary THA increases the risk for neck fracture, particularly in young male patients with cobalt-chromium long femoral necks. The bimodular stem we analyzed fractured unacceptably often, especially in younger male patients. For most patients, the risks of using this device outweigh the benefits, and several dozen patients had revisions and complications they would not have had if a different stem had been used. LEVEL OF EVIDENCE Level III, therapeutic study.
Collapse
Affiliation(s)
- Simon Kovač
- S. Kovač, V. Levašič, Valdoltra Orthopaedic Hospital, Ankaran, Slovenia B. Mavčič, Department of Orthopaedic Surgery, University Medical Centre Ljubljana, Ljubljana, Slovenia M. Kotnik, Department of Orthopaedics, Celje General Hospital, Celje, Slovenia M. Sirše, S. K. Fokter, Department of Orthopaedics, University Medical Centre Maribor, Maribor, Slovenia
| | | | | | | | | | | |
Collapse
|
18
|
Zajc J, Predan J, Gubeljak N, Moličnik A, Fokter SK. Modular femoral neck failure after revision of a total hip arthroplasty: a finite element analysis. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2018; 29:717-723. [PMID: 30317469 DOI: 10.1007/s00590-018-2314-8] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/31/2018] [Accepted: 10/07/2018] [Indexed: 12/14/2022]
Abstract
The authors report on a case of modular femoral neck fracture which appeared 21 months after revision of acetabular component. The revision surgery was performed 8 years after the primary total hip arthroplasty due to aseptic loosening of the acetabular component. During acetabular revision, the primary implanted short (S, - 3.5 mm) femoral head was also exchanged with extra-long (XL, + 7.0 mm) femoral head fitting the modular femoral neck with a longer lever arm. Numerical analysis has shown that this has resulted in a 19.9% increase in tensile stress at the neck-stem coupling during normal walking cycle. This could result in microcrack initiation and propagation and finally lead to modular neck failure of the otherwise well-fixed stem. Surgeons should avoid excessive loading of the exchangeable neck (dual-modular) femoral stem designs as the stem-neck couplings are subject to corrosion and are not as reliable as monoblock stems.
Collapse
Affiliation(s)
- Jan Zajc
- Faculty of Medicine, University of Maribor, Maribor, Slovenia
| | - Jožef Predan
- Faculty of Mechanical Engineering, University of Maribor, Maribor, Slovenia
| | - Nenad Gubeljak
- Faculty of Mechanical Engineering, University of Maribor, Maribor, Slovenia
| | - Andrej Moličnik
- Department for Orthopaedic Surgery, University Medical Center Maribor, Ljubljanska 5, 2000, Maribor, Slovenia
| | - Samo K Fokter
- Department for Orthopaedic Surgery, University Medical Center Maribor, Ljubljanska 5, 2000, Maribor, Slovenia.
| |
Collapse
|
19
|
Abstract
BACKGROUND Prevention of dislocation after primary total hip arthroplasty (THA) begins with patient preoperative assessment and planning. METHODS We performed a literature search to assess historical perspectives and current strategies to prevent dislocation after primary THA. The search yielded 3458 articles, and 154 articles are presented. RESULTS Extremes of age, body mass index >30 kg/m2, lumbosacral pathology, surgeon experience, and femoral head size influence dislocation rates after THA. There is mixed evidence regarding the effect of neuromuscular disease, sequelae of pediatric hip conditions, and surgical approach on THA instability. Sex, simultaneous bilateral THA, and restrictive postoperative precautions do not influence the dislocation rates of THA. Navigation, robotics, lipped liners, and dual-mobility acetabular components may improve dislocation rates. CONCLUSIONS Risks for dislocation should be identified, and measures should be taken to mitigate the risk. Reliance on safe zones of acetabular component positioning is historical. We are in an era of bespoke THA surgery.
Collapse
|