1
|
Bains SS, Dubin JA, Salib CG, Monárrez R, Remily E, Hameed D, Swartz GN, Katanbaf R, Nace J, Delanois RE. The Epidemiology of the Revision Total Hip Arthroplasty in the United States From 2016 to 2022. Arthroplast Today 2024; 30:101517. [PMID: 39524991 PMCID: PMC11550771 DOI: 10.1016/j.artd.2024.101517] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 07/16/2024] [Accepted: 08/13/2024] [Indexed: 11/16/2024] Open
Abstract
Background The number of revision total hip arthroplasties (THAs) is projected to reach 572,000 cases annually by 2030 in the United States. This may be attributed to the successes of primary THAs combined with an aging population, patients desire to remain active, and expanded indications for younger patients. Given the evolving nature of revision THAs, an epidemiological analysis of (1) etiologies; (2) demographics, including age and region; and (3) lengths of stay (LOSs) may minimize the gap between appropriate understanding and effective intervention. Methods From 2016 to 2022, a national, all-payer database was queried. Incidences and indications were analyzed for a total of 102,476 patients who had revision THA procedures. Patients were stratified according to etiology of failure, age, US census region, primary payor class, and mean LOS. Results The most common etiologies for revision THA procedures were dislocation (16.7%) and infection (12.7%), followed by periprosthetic fracture (6.9%). The largest age group was 65-74 years (30.9%), followed by >75 years (28.6%), then 55-64 (26.5%). The South had the largest total procedure cohort (36.9%), followed by the Midwest (27.5%), then the Northeast (19.7%), and the West (15.9%). The mean LOS was 4.10 days (range, 1.0-20.0). Conclusions Dislocation and infection remain leading indications for revision THA. These findings can properly guide surgeons toward appropriate management as well as toward active steps to minimizing these outcomes.
Collapse
Affiliation(s)
- Sandeep S. Bains
- Rubin Institute for Advanced Orthopedics, LifeBridge Health, Sinai Hospital of Baltimore, Baltimore, MD 21215, USA
| | - Jeremy A. Dubin
- Rubin Institute for Advanced Orthopedics, LifeBridge Health, Sinai Hospital of Baltimore, Baltimore, MD 21215, USA
| | - Christopher G. Salib
- Rubin Institute for Advanced Orthopedics, LifeBridge Health, Sinai Hospital of Baltimore, Baltimore, MD 21215, USA
| | - Rubén Monárrez
- Rubin Institute for Advanced Orthopedics, LifeBridge Health, Sinai Hospital of Baltimore, Baltimore, MD 21215, USA
| | - Ethan Remily
- Rubin Institute for Advanced Orthopedics, LifeBridge Health, Sinai Hospital of Baltimore, Baltimore, MD 21215, USA
| | - Daniel Hameed
- Rubin Institute for Advanced Orthopedics, LifeBridge Health, Sinai Hospital of Baltimore, Baltimore, MD 21215, USA
| | - Gabrielle N. Swartz
- Rubin Institute for Advanced Orthopedics, LifeBridge Health, Sinai Hospital of Baltimore, Baltimore, MD 21215, USA
| | - Reza Katanbaf
- Rubin Institute for Advanced Orthopedics, LifeBridge Health, Sinai Hospital of Baltimore, Baltimore, MD 21215, USA
| | - James Nace
- Rubin Institute for Advanced Orthopedics, LifeBridge Health, Sinai Hospital of Baltimore, Baltimore, MD 21215, USA
| | - Ronald E. Delanois
- Rubin Institute for Advanced Orthopedics, LifeBridge Health, Sinai Hospital of Baltimore, Baltimore, MD 21215, USA
| |
Collapse
|
2
|
Pitt CN, Ashkanfar A, English R, Naylor A, Öpöz TT, Langton DJ, Joyce TJ. Development of a bespoke finite element wear algorithm to investigate the effect of femoral centre of rotation on the wear evolution in total knee replacements. J Mech Behav Biomed Mater 2024; 163:106843. [PMID: 39647338 DOI: 10.1016/j.jmbbm.2024.106843] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2024] [Revised: 11/01/2024] [Accepted: 11/29/2024] [Indexed: 12/10/2024]
Abstract
Total Knee Replacements (TKRs) are a commonly used treatment to help patients suffering from severely damaged knee joints, which is normally brought on by osteoarthritis. The aim of the surgery is to reduce pain and regain function of the joint, however, some of these implants fail prematurely with implant wear being one of the main factors of failure. Computational analysis is an efficient tool that can provide an in-depth insight on the evolution of wear, before utilising experimental techniques which are time-consuming and costly. In this study, a bespoke finite element (FE) based wear algorithm has been further developed for TKRs and was used to investigate how location of femoral centre of rotation (CoR) affects the evolution of wear at the bearing surfaces. Three locations of femoral CoR have been investigated: international standards (ISO) CoR, being the location defined in ISO 14243-3, distal CoR being the centre of the femoral component's distal radius, and reference CoR being the middle ground between the two. All investigations were setup in accordance with ISO 14243-3 for displacement-controlled wear testing conditions for knee simulators. The wear algorithm extracts contact pressure and sliding distance from the FE analysis to determine wear depth, wear pattern, volumetric wear, and wear rates on the polymeric insert and femoral component's bearing surfaces using Archard's wear law. The polymeric insert volumetric wear rate after 5 million cycles (Mc) for ISO, reference, and distal CoR are 4.37mm3/Mc, 5.40mm3/Mc, and 6.83mm3/Mc respectively. Furthermore, the wear pattern's location on the bearing surfaces is dependent on the femoral CoR, with ISO CoR wear pattern being positioned more posteriorly, distal CoR being more anteriorly, and reference CoR in between ISO and distal. The ISO CoR investigation showed a region of minimal wear between two wear regions at the middle of the femoral component's wear pattern, on both medial and lateral condyles. This region of minimal wear reduces for the reference CoR and further reduces for the distal CoR. After 5 Mc, the average polymeric insert-femoral component contact area changes with femoral CoR, with the average contact area being 66.53mm2, 68.35mm2, and 71.21mm2 for ISO, reference, and distal CoRs respectively, with distal having around 7% more contact area than ISO. The results from this study show that there is a wide range of wear values for different locations of femoral CoR. As such the choice of femoral CoR should be carefully considered when performing any wear investigation to ensure that the CoR location is consistent for all studies being compared.
Collapse
Affiliation(s)
- Ciaran Neil Pitt
- School of Engineering, Liverpool John Moores University, Byrom Street, Liverpool, L3 3AF, UK.
| | - Ariyan Ashkanfar
- School of Engineering, Liverpool John Moores University, Byrom Street, Liverpool, L3 3AF, UK
| | - Russell English
- School of Engineering, Liverpool John Moores University, Byrom Street, Liverpool, L3 3AF, UK
| | - Andrew Naylor
- School of Engineering, Liverpool John Moores University, Byrom Street, Liverpool, L3 3AF, UK
| | - Tahsin T Öpöz
- School of Engineering, Liverpool John Moores University, Byrom Street, Liverpool, L3 3AF, UK
| | | | - Thomas J Joyce
- School of Engineering, Newcastle University, Newcastle Upon Tyne, NE1 7RU, UK
| |
Collapse
|
3
|
Escobar-Medina JA, Barceinas-Sanchez JDO. Behavior of the Coefficient of Friction of Textured Tibial Inserts of Total Knee Replacements under the Conditions Prescribed by ISO 14243-3:2014. TRIBOLOGY TRANSACTIONS 2024; 67:847-856. [DOI: 10.1080/10402004.2024.2384516] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2024] [Revised: 07/18/2024] [Accepted: 07/19/2024] [Indexed: 01/03/2025]
Affiliation(s)
- J. A. Escobar-Medina
- National Polytechnic Institute—Center for Research in Applied Science and Advanced Technology Queretaro Unit, Queretaro, Mexico
| | - J. D. O. Barceinas-Sanchez
- National Polytechnic Institute—Center for Research in Applied Science and Advanced Technology Queretaro Unit, Queretaro, Mexico
| |
Collapse
|
4
|
van Duren BH, France J, Berber R, Matar HE, James PJ, Bloch BV. Is there an increased revision rate due to early tibial component loosening with a modern total knee arthroplasty design? A retrospective analysis from a large volume arthroplasty centre. ARTHROPLASTY 2024; 6:46. [PMID: 39095924 PMCID: PMC11297728 DOI: 10.1186/s42836-024-00264-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2024] [Accepted: 05/21/2024] [Indexed: 08/04/2024] Open
Abstract
BACKGROUND The Attune TKR was introduced in 2011 as a successor to its predicate design The PFC Sigma. However, following reports of early failures, there are ongoing concerns related to increased loosening rates. Given the concerns, this study aimed to compare revision rates of the Attune implant to an established predicate, and other implant designs used in a high-volume arthroplasty center. METHODS We identified 10,202 patients who underwent primary cemented TKR at our institution with a minimum of 1 year follow-up, involving 2406 Attune TKR (557 S +), 4642 PFC TKR, 3154 other designs. Primary outcomes were revision for all-causes, aseptic loosening of any component, and aseptic tibial loosening. Kaplan-Meier survival and Cox regression models were used to compare groups. Matched cohorts were selected for radiographic analysis. RESULTS 308 knees were revised. The Attune cohort had the lowest risk of revision, with a rate of 2.98 per 1000 implant-years while the PFC and All Other Implant groups had a rate of 3.15 and 4.4 respectively. Aseptic loosing was the most common cause for revision, with 76% (65/88) involving the tibia. Survival analysis showed no significant differences between the Attune and other cohorts. Radiolucent lines were detected in 7.1% of the Attune S + group, 6.8% of the standard Attune group, and 6.3% of the PFC group, with no significant differences found between them. CONCLUSION This study represents the largest non-registry review of the Attune TKR in comparison to a predicate and other designs. There was no significant increased revision rate for all-cause revision or aseptic loosening, or peri-implant radiolucencies. It appears that increased loosening may not be as concerning as originally thought. LEVEL OF EVIDENCE Level III.
Collapse
Affiliation(s)
- Bernard H van Duren
- Nottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, NG5 1PB, UK.
- Leeds Orthopaedic and Trauma Sciences, Leeds Institute of Rheumatic and Musculoskeletal Medicine, University of Leeds, Leeds, LS2 9JT, UK.
| | - Jonathan France
- Nottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, NG5 1PB, UK
| | - Reshid Berber
- Nottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, NG5 1PB, UK
| | - Hosam E Matar
- Nottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, NG5 1PB, UK
| | - Peter J James
- Nottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, NG5 1PB, UK
| | - Benjamin V Bloch
- Nottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, NG5 1PB, UK
- University of Nottingham, School of Medicine, Nottingham, UK
| |
Collapse
|
5
|
Manzetti M, Digennaro V, Di Martino A, Bordini B, Benvenuti L, Ferri R, Cecchin D, Faldini C. Survivorship of total knee arthroplasty in poliomyelitis patients: long-term results from the R.I.P.O. registry and single-institution retrospective study. Arch Orthop Trauma Surg 2024; 144:3641-3648. [PMID: 39069565 PMCID: PMC11417051 DOI: 10.1007/s00402-024-05426-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/30/2023] [Accepted: 06/26/2024] [Indexed: 07/30/2024]
Abstract
INTRODUCTION The survival of total knee arthroplasty (TKA) in patients with poliomyelitis remains a debated topic due to the high recurrence of postoperative genu recurvatum. This study aims to report the long-term survival of TKA in patients with poliomyelitis, using data from the Italian Register of Prosthetic Implantology. MATERIALS AND METHODS A registry-based population study was conducted, utilizing data from the Emilia Romagna orthopedic arthroplasty implants registry (RIPO - Registro Implantologia Protesica Ortopedica). The cohort consisted of 71 patients with poliomyelitis-related arthritis who underwent TKA. The study assessed and analyzed demographic data, implant type, fixation method, insert type, and level of constraint. Additionally, variations in preoperative and postoperative both clinical and functional Knee Society Scores (KSS) were collected. RESULTS Eight implants required revision surgery (16%), and three patients died (6.1%), resulting in a 10-year survival rate of 86.6% and a 15-year survival rate of 53.9%. Aseptic loosening was the primary cause of revision, accounting for 37.5% of failures, followed by insert wear (25%). No statistically significant correlation was found between the level of constraint and implant survival (p=0.0887, log-rank). Both the clinical and functional KSS improved postoperatively. CONCLUSION TKA is a viable alternative to knee arthrodesis and, in properly selected patients, might represent the first-choice treatment for articular degeneration due to its high survivorship. Despite the complexity of these cases, TKA can effectively alleviate articular pain, instability, and angular deviation, thereby preserving knee functionality.
Collapse
Affiliation(s)
- Marco Manzetti
- IRCCS - Istituto Ortopedico Rizzoli, Bologna, 40136, Italy.
- Department of Biomedical and Neuromotor Science-DIBINEM, University of Bologna, Bologna, Italy.
| | - V Digennaro
- IRCCS - Istituto Ortopedico Rizzoli, Bologna, 40136, Italy
| | - A Di Martino
- IRCCS - Istituto Ortopedico Rizzoli, Bologna, 40136, Italy
- Department of Biomedical and Neuromotor Science-DIBINEM, University of Bologna, Bologna, Italy
| | - B Bordini
- Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, Via Giulio Cesare Pupilli, 1, Bologna, 40136, Italy
| | - L Benvenuti
- IRCCS - Istituto Ortopedico Rizzoli, Bologna, 40136, Italy
| | - R Ferri
- IRCCS - Istituto Ortopedico Rizzoli, Bologna, 40136, Italy
| | - D Cecchin
- IRCCS - Istituto Ortopedico Rizzoli, Bologna, 40136, Italy
| | - C Faldini
- IRCCS - Istituto Ortopedico Rizzoli, Bologna, 40136, Italy
- Department of Biomedical and Neuromotor Science-DIBINEM, University of Bologna, Bologna, Italy
| |
Collapse
|
6
|
Karpiński R, Machrowska A, Maciejewski M, Jonak J, Krakowski P. CONCEPT AND VALIDATION OF A SYSTEM FOR RECORDING VIBROACOUSTIC SIGNALS OF THE KNEE JOINT. INFORMATYKA, AUTOMATYKA, POMIARY W GOSPODARCE I OCHRONIE ŚRODOWISKA 2024; 14:17-21. [DOI: 10.35784/iapgos.6139] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/03/2025]
Abstract
Cartilage degeneration is a serious health condition in modern society, leading to problems in mobility and significant reduction in the quality of life of patients of all ages. It is mainly caused by obesity, workload, sports or trauma to the joint. Proper diagnosis is crucial to implement appropriate treatment to stop the further degeneration of the tissue. Usually the assessment is performed by using magnetic resonance. This paper describes the design and application of an alternative measurement system for vibroartography of the knee joint. The use of such device allows for fast, safe, easy and cheap assessment of joint condition, which in turn can lead to proper treatment planning. Similar portable systems can be rapidly deployed and used by entry level medical staff in hospitals, clinics or at patient’s home. The system consists of an orthosis, set of three vibroacoustic sensors, encoder for reading knee position, microcontroller with galvanic barrier and battery power and a computer for data storage and processing. The system is light, simple and portable. Data is recorded in both closed and open kinematic chains. Results show over 90% diagnostic accuracy based on the data obtained in the process of testing this device. In the future, the system will be further miniaturized and completely placed on the orthosis, leading to more portability and diagnostic merit.
Collapse
|
7
|
Yu M, Xu Y, Weng X, Feng B. Clinical outcome and survival rate of condylar constrained knee prosthesis in revision total knee arthroplasty: an average nine point six year follow-up. INTERNATIONAL ORTHOPAEDICS 2024; 48:1179-1187. [PMID: 38353709 DOI: 10.1007/s00264-024-06096-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Accepted: 01/17/2024] [Indexed: 04/10/2024]
Abstract
PURPOSE Condylar constrained knee prostheses (CCK) are increasingly used in revision total knee arthroplasty (rTKA), but the clinical effectiveness and long-term survival remain a debate. The purpose of this study is to report the long-term clinical and radiographic outcome, implant survival rate, and surgical safety of revision total knee arthroplasty with condylar constrained knee prosthesis. METHODS A retrospective cohort study was performed on patients undergoing rTKA with CCK. The cases who received rTKA with CCK from January 2005 to January 2022 were selected. The duration of operation, the estimated perioperative blood loss, and the intraoperative blood transfusion rate were recorded to evaluate surgical safety. The pain visual analog scale (VAS), range of motion (ROM), the Hospital for Special Surgery (HSS) score, the Knee Society Score (KSS), the Western Ontario and McMaster University Osteoarthritis Index (WOMAC), and the Oxford knee score (OKS) was recorded to assess clinical outcome. Standard anteroposterior, lateral, skyline and long-standing AP radiographs of the lower limbs were conducted to assess radiographic outcome. Implant survival was analyzed by Kaplan-Meier survival estimates. RESULTS Fifty-five cases were followed up for an average of 9.6 years (1-18 years), including 16 males and 38 females, with an average age of 66 and an average BMI of 26.9 kg/m2. The main reasons for revision were periprosthetic infection (32 knees, 58.2%) and aseptic loosening (13 knees, 23.6%). The duration of operation was 149 ± 56.2 min. The perioperative blood loss was 973.6 ± 421.6 ml. At the last follow-up, VAS (8.0 ± 1.1 to 1.3 ± 1.4), ROM (82.7° ± 26.1° to 108.4° ± 11.8°), HSS (45.0 ± 10.4 to 85.3 ± 8.6), KSKS (38.4 ± 12.1 to 88.5 ± 12.0), KSFS (19.6 ± 12.9 to 68.8 ± 15.1), WOMAC (67.9 ± 12.5 to 14.4 ± 9.5), and OKS (9.9 ± 4.2 to 41.6 ± 7.7) were significantly improved (P < 0.001). A total of five complications were observed, all of which were periprosthetic infection. Non-progressive radiolucent lines were observed in 26 knees (47.3%). The 10-year survival rate for no operation was 96.0%. The ten year survival rate for no revision was 98.0%. CONCLUSION The use of CCK prosthesis for rTKA can achieve good long-term efficacy and prosthesis survival.
Collapse
Affiliation(s)
- Muyang Yu
- Department of Orthopedics Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100730, China
| | - Yiming Xu
- Department of Orthopedics Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100730, China
| | - Xisheng Weng
- Department of Orthopedics Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100730, China.
- State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing, 100730, China.
| | - Bin Feng
- Department of Orthopedics Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100730, China.
| |
Collapse
|
8
|
Hawes J, Ast M, Mayman D, Bostrom M, Haas S, Chalmers B. Excellent 2-Year Outcomes of a Midlevel Constrained Liner Used in Stemless Primary TKA. HSS J 2024:15563316241233293. [PMID: 39564425 PMCID: PMC11572455 DOI: 10.1177/15563316241233293] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/12/2023] [Accepted: 01/05/2024] [Indexed: 11/21/2024]
Abstract
Introduction Instability after total knee arthroplasty (TKA) remains a leading cause of revision TKA and can lead to patient dissatisfaction. While many companies have developed midlevel constrained (MLC) polyethylene inserts in primary TKAs, there is little data on their outcomes. Purpose We sought to analyze short-term outcomes including survivorship, rates of manipulation under anesthesia (MUA), and improvements in patient-reported outcome measures (PROMs) preoperatively to postoperatively in one design of MLC TKA. Methods We prospectively followed consecutive primary TKA patients who received constrained inserts (Journey II or Legion Genesis II, Smith and Nephew) from 5 surgeons, 2019 to 2020, at a single academic institution. We analyzed revision-free survivorship, MUA rates, and PROMs, preoperatively to postoperatively. Results A total of 356 patients were included with a mean age of 64 years; 49% were male and the mean body mass index (BMI) was 31 kg/m2. Sixteen patients (4.5%) underwent MUA and 3 patients (0.8%) underwent revision. Two patients underwent polyethylene exchange and patellar resection for patellar loosening. One patient underwent liner exchange for instability. The 2-year revision-free survivorship was 98.5% (95% confidence interval [CI]: 96.6%-100%). Survivorship free from revision for tibial or femoral aseptic loosening was 100% at 2 years. The 2-year survivorship free from MUA was 92.3% (95% CI: 88.6%-96.1%). The mean Knee Osteoarthritis and Injury Outcomes Score Joint Replacement (KOOS JR) was 81 at 2 years follow-up, while the Lower Extremity Activity Score (LEAS) score was 10.5. Conclusion At a mean of 3 years follow-up, 2 types of MLCs used in primary TKA were associated with a low rate of early revision, low rate of MUA, and reliable improvement in functional outcomes. These MLCs were not associated with early loosening or unique failure modes.
Collapse
Affiliation(s)
- Joseph Hawes
- Department of Orthopedic Surgery, Hospital for Special Surgery, New York, NY, USA
| | - Michael Ast
- Department of Orthopedic Surgery, Hospital for Special Surgery, New York, NY, USA
| | - David Mayman
- Department of Orthopedic Surgery, Hospital for Special Surgery, New York, NY, USA
| | - Mathias Bostrom
- Department of Orthopedic Surgery, Hospital for Special Surgery, New York, NY, USA
| | - Steven Haas
- Department of Orthopedic Surgery, Hospital for Special Surgery, New York, NY, USA
| | - Brian Chalmers
- Department of Orthopedic Surgery, Hospital for Special Surgery, New York, NY, USA
| |
Collapse
|
9
|
Zgouridou A, Kenanidis E, Potoupnis M, Tsiridis E. Global mapping of institutional and hospital-based (Level II-IV) arthroplasty registries: a scoping review. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY : ORTHOPEDIE TRAUMATOLOGIE 2024; 34:1219-1251. [PMID: 37768398 PMCID: PMC10858160 DOI: 10.1007/s00590-023-03691-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Accepted: 08/13/2023] [Indexed: 09/29/2023]
Abstract
PURPOSE Four joint arthroplasty registries (JARs) levels exist based on the recorded data type. Level I JARs are national registries that record primary data. Hospital or institutional JARs (Level II-IV) document further data (patient-reported outcomes, demographic, radiographic). A worldwide list of Level II-IV JARs must be created to effectively assess and categorize these data. METHODS Our study is a systematic scoping review that followed the PRISMA guidelines and included 648 studies. Based on their publications, the study aimed to map the existing Level II-IV JARs worldwide. The secondary aim was to record their lifetime, publications' number and frequency and recognise differences with national JARs. RESULTS One hundred five Level II-IV JARs were identified. Forty-eight hospital-based, 45 institutional, and 12 regional JARs. Fifty JARs were found in America, 39 in Europe, nine in Asia, six in Oceania and one in Africa. They have published 485 cohorts, 91 case-series, 49 case-control, nine cross-sectional studies, eight registry protocols and six randomized trials. Most cohort studies were retrospective. Twenty-three per cent of papers studied patient-reported outcomes, 21.45% surgical complications, 13.73% postoperative clinical and 5.25% radiographic outcomes, and 11.88% were survival analyses. Forty-four JARs have published only one paper. Level I JARs primarily publish implant revision risk annual reports, while Level IV JARs collect comprehensive data to conduct retrospective cohort studies. CONCLUSIONS This is the first study mapping all Level II-IV JARs worldwide. Most JARs are found in Europe and America, reporting on retrospective cohorts, but only a few report on studies systematically.
Collapse
Affiliation(s)
- Aikaterini Zgouridou
- Academic Orthopaedic Department, Aristotle University Medical School, General Hospital Papageorgiou, Ring Road Efkarpia, 56403, Thessaloniki, Greece
- Centre of Orthopaedic and Regenerative Medicine (CORE), Center for Interdisciplinary Research and Innovation (CIRI)-Aristotle University of Thessaloniki (AUTH), Balkan Center, Buildings A & B, 10th km Thessaloniki-Thermi Rd, P.O. Box 8318, 57001, Thessaloniki, Greece
| | - Eustathios Kenanidis
- Academic Orthopaedic Department, Aristotle University Medical School, General Hospital Papageorgiou, Ring Road Efkarpia, 56403, Thessaloniki, Greece.
- Centre of Orthopaedic and Regenerative Medicine (CORE), Center for Interdisciplinary Research and Innovation (CIRI)-Aristotle University of Thessaloniki (AUTH), Balkan Center, Buildings A & B, 10th km Thessaloniki-Thermi Rd, P.O. Box 8318, 57001, Thessaloniki, Greece.
| | - Michael Potoupnis
- Academic Orthopaedic Department, Aristotle University Medical School, General Hospital Papageorgiou, Ring Road Efkarpia, 56403, Thessaloniki, Greece
- Centre of Orthopaedic and Regenerative Medicine (CORE), Center for Interdisciplinary Research and Innovation (CIRI)-Aristotle University of Thessaloniki (AUTH), Balkan Center, Buildings A & B, 10th km Thessaloniki-Thermi Rd, P.O. Box 8318, 57001, Thessaloniki, Greece
| | - Eleftherios Tsiridis
- Academic Orthopaedic Department, Aristotle University Medical School, General Hospital Papageorgiou, Ring Road Efkarpia, 56403, Thessaloniki, Greece
- Centre of Orthopaedic and Regenerative Medicine (CORE), Center for Interdisciplinary Research and Innovation (CIRI)-Aristotle University of Thessaloniki (AUTH), Balkan Center, Buildings A & B, 10th km Thessaloniki-Thermi Rd, P.O. Box 8318, 57001, Thessaloniki, Greece
| |
Collapse
|
10
|
Wojtowicz R, Otten V, Henricson A, Crnalic S, Nilsson KG. Uncemented trabecular metal high-flex posterior-stabilized monoblock total knee arthroplasty in patients aged 60 years or younger. Knee 2024; 46:99-107. [PMID: 38070382 DOI: 10.1016/j.knee.2023.11.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Revised: 10/10/2023] [Accepted: 11/13/2023] [Indexed: 02/20/2024]
Abstract
BACKGROUND Uncemented trabecular metal (TM) monoblock tibial components in total knee arthroplasty (TKA) have shown excellent clinical results for up to 10 years. However, these studies were performed in highly specialized units, with few surgeons and often excluding knees with secondary osteoarthritis (OA), severe malalignments and previous surgery. The purpose of this study was to investigate implant survivorship and clinical and radiological outcome of the uncemented TM high-flex posterior stabilized (PS) monoblock tibial component in routine clinical practice. METHODS A retrospective study of 339 knees (282 patients) operated with the implant in routine clinical practice at two hospitals on patients aged 60 years or younger between 2007 and 2015. The operations were performed by 12 surgeons and there were no specific contraindications for use of the implant. Follow up ended in 2020. The status of the implant of deceased patients at death and those not attending follow up was checked with the Swedish Knee Arthroplasty Register. Clinical follow up consisted of clinical investigation, PROMs, and knee X-ray. RESULTS Follow up was mean (range) 8.5 (5-13.8) years, and the 8-year survival rate was 0.98 (standard error 0.007). Five patients five knees) were deceased, five knees were revised (none due to aseptic loosening), and 16 patients did not attend the clinical follow up. Forty-four percent of the knees had secondary OA and 45% had had previous operations. 93% were satisfied or very satisfied with the operation and forgotten joint score (FJS) was median (interquartile range) 81 (44-94). Radiographic analysis revealed bone in close contact with the tibial tray and pegs in most cases, and in only 2% of the knees were potential radiolucent lines found. CONCLUSION The results indicate that this uncemented implant performs excellently in routine clinical practice and also in younger patients with secondary OA or previous knee operations.
Collapse
Affiliation(s)
- Radoslaw Wojtowicz
- Department of Surgical and Perioperative Sciences - Orthopedics, Umeå University, Umeå, Sweden.
| | - Volker Otten
- Department of Surgical and Perioperative Sciences - Orthopedics, Umeå University, Umeå, Sweden
| | - Anders Henricson
- Department of Orthopedics, Falun General Hospital, Falun, Sweden
| | - Sead Crnalic
- Department of Surgical and Perioperative Sciences - Orthopedics, Umeå University, Umeå, Sweden
| | - Kjell G Nilsson
- Department of Surgical and Perioperative Sciences - Orthopedics, Umeå University, Umeå, Sweden
| |
Collapse
|
11
|
Perdisa F, Bordini B, Salerno M, Traina F, Zaffagnini S, Filardo G. Total Knee Arthroplasty (TKA): When Do the Risks of TKA Overcome the Benefits? Double Risk of Failure in Patients up to 65 Years Old. Cartilage 2023; 14:305-311. [PMID: 37073516 PMCID: PMC10601565 DOI: 10.1177/19476035231164733] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Revised: 02/28/2023] [Accepted: 03/04/2023] [Indexed: 04/20/2023] Open
Abstract
OBJECTIVE The aim of this study was to document the survival rate in the middle-aged patient group up to 65 years old and to compare it with other age groups of patients undergoing total knee arthroplasty (TKA) for knee osteoarthritis (OA). DESIGN The Register of Orthopaedic Prosthetic Implants (RIPO) regional registry was used to analyze the results of patients <80 years old affected by primary OA and treated with TKA from 2000 to 2019. The database was investigated according to the age group: younger than 50 years, 50-65 years, or 66-79 years, with the aim to estimate revision surgeries and implant survivorship. RESULTS A total of 45,488 TKAs for primary OA were included in the analysis (M: 11,388; F: 27,846). The percentage of patients <65 years old increased from 13.5% to 24.8% between 2000 and 2019 (P < 0.0001). The survival analysis showed an overall influence of age on the implant revision rate (P < 0.0001), with an estimated survival rate of 78.7%, 89.4%, and 94.8% at 15 years in the 3 groups, respectively. Compared with the older-aged group, the relative risk of failure was 3.1 (95% confidence interval [CI] = 2.2-4.3; P < 0.001) higher in patients <50 years old and 1.8 (95% CI = 1.6-2.0; P < 0.001) higher in patients 50-65 years old. CONCLUSIONS TKA use in the middle-aged patient population up to 65 years old increased significantly over time. These patients present a double risk of failure with respect to older patients. This is particularly important considering the increasing life expectancy and the emergence of new joint preserving strategies, which could postpone the need for TKA to an older age.
Collapse
Affiliation(s)
| | - Barbara Bordini
- Medical Technology Laboratory, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Manuela Salerno
- Applied and Translational Research Center, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Francesco Traina
- Orthopaedic-Traumatology and Prosthetic Surgery and Revisons of Hip and Knee Implants, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Stefano Zaffagnini
- 2nd Orthopaedic and Traumatologic Clinic, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Giuseppe Filardo
- Applied and Translational Research Center, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| |
Collapse
|
12
|
McCormick BP, Trent S, Geng X, Lee JW, Boucher HR. Robotic-assisted technology does not influence functional outcomes among obese and morbidly obese total knee arthroplasty patients. J Exp Orthop 2023; 10:76. [PMID: 37523073 PMCID: PMC10390435 DOI: 10.1186/s40634-023-00634-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/08/2023] [Accepted: 07/05/2023] [Indexed: 08/01/2023] Open
Abstract
PURPOSE Despite benefits of total knee arthroplasty (TKA) on function and quality of life, obese patients have less improved functional outcomes following TKA compared to their normal weight counterparts. Furthermore, obesity is a risk factor for aseptic loosening and revision surgery following TKA. With known benefits of robotic-assisted TKA (RaTKA) in precision and patient satisfaction, we aimed to evaluate the differences in patient reported outcome and early complication rates for patients undergoing RaTKA versus conventional TKA among patients of varying BMI groups. METHODS This study was a retrospective cohort study of patients who underwent conventional versus RaTKA. Patients were grouped by BMI range (< 30 kg/m2, 30-40 kg/m2, and > 40 kg/m2). Patient-reported outcomes were measured by Oxford Knee Scores and 12-Item Short Form Survey scores preoperatively, 6-month, 1-year, and 2-year postoperatively. Mixed-effects linear models were built for each patient-reported outcome to assess the interaction between type of surgery and BMI while adjusting for known confounders such as demographic variables. RESULTS A total of 350 patients (n = 186 RaTKA, n = 164 conventional TKA) met inclusion criteria. SF-12 physical scores were significantly higher at 2-year follow-up among non-obese patients compared to obese and morbidly obese patients (p = 0.047). There was no statistically significant interaction between the type of surgery performed (RaTKA versus conventional TKA) and obesity regarding their effects on patient reported outcomes. CONCLUSIONS This study demonstrates no differences in functional outcomes among patients undergoing RaTKA compared to conventional TKA. Furthermore, obesity had no significant effect on this association. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- Brian P McCormick
- Department of Orthopaedic Surgery, MedStar Union Memorial Hospital, 3333 North Calvert Street, Suite 400, Baltimore, MD, 21218, USA.
| | - Sarah Trent
- Department of Orthopaedic Surgery, Donald and Barbara Zucker School of Medicine at Hofstra / Northwell, Great Neck, NY, USA
| | - Xue Geng
- Department of Biostatistics, Georgetown University School of Medicine, Washington, D.C, USA
| | - Ji Won Lee
- Department of Orthopaedic Surgery, MedStar Union Memorial Hospital, 3333 North Calvert Street, Suite 400, Baltimore, MD, 21218, USA
| | - Henry R Boucher
- Department of Orthopaedic Surgery, MedStar Union Memorial Hospital, 3333 North Calvert Street, Suite 400, Baltimore, MD, 21218, USA
| |
Collapse
|
13
|
Kanna R, Murali SM, Ramanathan AT, Pereira L, Yadav CS, Anand S. Cruciate retaining total knee arthroplasty has a better 10 year survival than posterior stabilized total knee arthroplasty: a systematic review and meta-analysis. J Exp Orthop 2023; 10:19. [PMID: 36800047 PMCID: PMC9938095 DOI: 10.1186/s40634-023-00583-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/25/2022] [Accepted: 02/04/2023] [Indexed: 02/18/2023] Open
Abstract
PURPOSE There has been a long standing debate regarding superiority of cruciate retaining total knee arthroplasty over posterior stabilized total knee arthroplasty regarding the short-term outcomes as well as long-term survivorship. The proponents of both the techniques have published vast evidence in favor of their respective surgical method and early outcome in meta-analyses does not seem to be significantly different. The decision to select either design should depend on their long-term survivorship but the literature comparing their long-term survival is sparse.This meta-analysis was conducted in order to answer the following questions: (1) Does cruciate retaining total knee arthroplasty has a better long-term survival beyond 10 years.compared to posterior stabilized total knee arthroplasty? (2) Does cruciate retaining knee arthroplasty has higher complication rates compared to posterior stabilized total knee arthroplasty? METHODS The present systematic review and meta-analysis study was carried out following PRISMA guidelines. The following databases: Embase, Web of Science, PubMed, Scopus, the Cochrane Library, Google Scholar, and CINAHL were used to search potentially interesting articles published from database inception until January 2022. Inclusion criteria for articles were: (1) retrospective comparative studies; (2) patients who had undergone a total knee arthroplasty; (3) publications evaluating the long-term survival of cruciate-retaining (CR) versus posterior stabilizing (PS) at a minimum 10 years' follow-up; (4) publications evaluating complications of cruciate-retaining (CR) versus posterior stabilizing (PS) at a minimum 10 years' follow-up; and (5) publications reporting sufficient data regarding the outcomes. We used a fixed-effects design in the case of I2 < 50% and P > 0.05; if not, we adopted a random-effects design [4]. We also performed subgroups and sensitivity analysis in order to assess the possible source of heterogeneity. RESULTS Database searching identified 597 studies to be screened, of which 291 abstracts were revealed as potentially eligible and finally 7 articles were included. The forest plot showed that CR had significantly better survival than PS (OR = 2.17; 95% CI: 1.69-2.80) after 10 years. However, complication rate was not significantly different between CR and PS groups (OR = 0.86; 95% CI: 0.52-1.44; P = 0.57). Subgroup analysis showed that only the period of publication constituted a source of heterogeneity in survivorship outcome. Sensitivity analysis revealed that outcomes did not differ markedly, which indicates that the meta-analysis had strong reliability. CONCLUSION The results of this meta-analysis showed that cruciate retaining prosthesis may be preferred over the posterior stabilized design in view of longer survivorship it offers However, further randomized controlled trials are recommended to confirm this finding.
Collapse
Affiliation(s)
- Raj Kanna
- Associate Professor in Orthopaedics, Madha Medical College and Research Institute, Chennai, Tamil Nadu India
| | - S. M. Murali
- Associate Profesoor in Orthopaedics, SMMCH&RI Chennai, 600 069, Tamil Nadu India
| | - Ashok Thudukuchi Ramanathan
- Associate Professor in Orthopaedics, Sri Ramchandran Institute of Higher Education and Research, Chennai, India
| | - Lester Pereira
- Department of Orthopaedics, Primus Hospital, Delhi, India
| | - C. S. Yadav
- Department of Orthopaedics, Primus Hospital, Delhi, India
| | - Sumit Anand
- Department of Orthopaedics, Primus Hospital, Delhi, India.
| |
Collapse
|
14
|
Guarino A, Farinelli L, Iacono V, Cozzolino A, Natali S, Zorzi C, Mariconda M. Long-Term Survival and Predictors of Failure of Opening Wedge High Tibial Osteotomy. Orthop Surg 2023; 15:1002-1007. [PMID: 36782306 PMCID: PMC10102285 DOI: 10.1111/os.13674] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Revised: 01/13/2023] [Accepted: 01/13/2023] [Indexed: 02/15/2023] Open
Abstract
OBJECTIVE High tibial valgus osteotomy (HTO) is a widely accepted procedure indicated for varus knee with symptomatic osteoarthritis of the medial compartment. However, there is a lack of studies evaluating long term results of this procedure. The primary aim of this study was to evaluate the long-term survival of opening wedge high tibial osteotomy (HTO) for isolated osteoarthritis in the medial compartment of the knee. The secondary objective was to identify independent predictors of conversion to total knee arthroplasty (TKA). METHODS This is a long term retrospective study of 296 cases of open wedge HTOs performed at a single center (level of evidence IV) between January 2005 and August 2015. Opening wedge medial HTO was always performed after diagnostic arthroscopy. Eighty-three percent of the population (233 patients, 247 procedures) was followed up at a mean 11.6 years (6-17) by telephone interview, to evaluate the possible conversion to TKA. Mean age at the index operation was 42.8 years (range 15-70) and most patients were male (70%). Associated procedures (e.g., platelet rich plasma supplementation, microfractures, meniscectomy, etc.) were carried out at the time of the HTO in 80 (32%) cases. Survival of HTO and its association with age, sex, body mass index, smoking habit, preoperative severity of varus deformity, cartilage status at surgery, and associated procedures were evaluated. Kaplan-Meier and Cox regression analyses were performed. RESULTS Thirty-three of the 247 HTOs (13.4%) were converted to knee replacement, with 86.6% of the original procedures surviving at a mean 12-year follow-up. Kaplan-Meier survival estimates at 17 years for HTO were 75.5% (95% confidence interval [CI] 66.7-84.3). There was significant difference (P < 0.001) in the 17-year survival rate between obese (55.5%; 95% CI 35.3-75.6) and non-obese (79.7%; 95% CI 70.1-89.2) patients. The determinants of conversion to knee arthroplasty detected at multivariate Cox regression analysis were body mass index, severity of cartilage degeneration in the medial compartment (Outerbridge grade), and age. CONCLUSION The long-term survival of open wedge HTO for osteoarthritis in the medial compartment of the knee is satisfactory. The risk of conversion to TKA is significantly increased in obese patients. Advanced age and severity of pre-existing cartilage damage may also contribute to the risk of conversion to TKA.
Collapse
Affiliation(s)
- Amedeo Guarino
- Department of Public Health, Section of Orthopaedics, Federico II University, Naples, Italy
| | - Luca Farinelli
- Orthopaedic Clinic, Department of Clinical and Molecular Sciences, Università Politecnica delle Marche, Ancona, Italy
| | - Venanzio Iacono
- Department of Orthopaedic Surgery, IRCCS Sacro Cuore-Don Calabria in Negrar (VE), Negrar di Valpolicella VR, Italy
| | - Andrea Cozzolino
- Department of Public Health, Section of Orthopaedics, Federico II University, Naples, Italy
| | - Simone Natali
- Department of Orthopaedic Surgery, IRCCS Sacro Cuore-Don Calabria in Negrar (VE), Negrar di Valpolicella VR, Italy
| | - Claudio Zorzi
- Department of Orthopaedic Surgery, IRCCS Sacro Cuore-Don Calabria in Negrar (VE), Negrar di Valpolicella VR, Italy
| | - Massimo Mariconda
- Department of Public Health, Section of Orthopaedics, Federico II University, Naples, Italy
| |
Collapse
|
15
|
Outcomes of Plug Osteochondral Allograft Transplantation With or Without Concomitant Osteotomy for Cartilage Defects in the Knee: Minimum 2-year Follow-up. J Am Acad Orthop Surg 2023; 31:e73-e81. [PMID: 36580053 DOI: 10.5435/jaaos-d-22-00109] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Accepted: 08/05/2022] [Indexed: 12/30/2022] Open
Abstract
INTRODUCTION Isolated osteochondral defects of the knee can cause notable pain and disability. Osteochondral allograft (OCA) transplantation using trephined plug grafts is a highly effective, often curative, treatment option. In knees with malalignment into the transplanted compartment, osteotomy can be done concurrently. This study investigates early-to-midterm survivorship, as well as clinical and radiographic outcomes, of plug OCAs with and without concomitant osteotomy in the knee. METHODS Plug OCA was done on active, young to middle-aged patients with osteochondral defects ≤4 cm diameter. Prospectively collected data for 102 patients who underwent plug OCA between 2004 and 2020 were reviewed. Survivorship according to Kaplan-Meier analysis was the primary outcome. Failure was defined as conversion to total knee arthroplasty or repeat allograft. Clinical and radiographic outcomes were evaluated using the modified Hospital for Special Surgery (mHSS) score and Kellgren-Lawrence grading. RESULTS Eighty-six patients with a mean age of 29 ± 9.7 years (15 to 54) and a mean follow-up of 6.8 ± 3.7 years (2 to 15.9) were studied. Concomitant realignment osteotomy was done in 66 patients (76.7%). Graft survivorship was 100%, 93.8% (95% confidence interval 90.8% to 96.8%), and 89.7% (95% confidence interval 85.6% to 93.8%) at 2, 5, and 10 to 15 years, respectively. Six grafts (7.0%) required knee arthroplasty at a mean of 4.6 ± 1.8 years (2.2 to 7.1). Most common reasons for revision surgeries with graft retention included implant removal (11.6%), débridement (8.1%), and repeat osteotomy (5.8%). The mean mHSS score of 90.8 ± 10.4 (51 to 100) at the final follow-up was significantly higher than the preoperative value of 72.5 ± 12.1 (36 to 90) (P < 0.001). Subgroup analyses revealed a markedly greater risk of failure in grafts with a diameter of 30 mm or larger. DISCUSSION Plug OCA with or without concurrent realignment osteotomy resulted in an excellent graft survival of 93% at a mean of 6.8 years, with reliable functional improvement demonstrated by notable improvements in mHSS knee scores.
Collapse
|
16
|
Primary Total Knee Arthroplasty in Patients Aged 45 Years or Younger: 162 Total Knee Arthroplasties With a Mean Follow-up Duration of 7 Years. Arthroplast Today 2022. [DOI: 10.1016/j.artd.2022.09.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
17
|
Castagnini F, Bordini B, Cosentino M, Ancarani C, Lucchini S, Bracci G, Traina F. Constraint in complex primary total knee arthroplasty: rotating hinge versus condylar constrained implants. Arch Orthop Trauma Surg 2022; 142:3965-3973. [PMID: 35083520 DOI: 10.1007/s00402-021-04322-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/01/2021] [Accepted: 12/14/2021] [Indexed: 02/07/2023]
Abstract
INTRODUCTION Condylar constrained knee arthroplasties (CCKAs) and rotating hinge knee arthroplasties (RHKAs) achieved good outcomes in complex primary total knee arthroplasties (TKAs); however, long-term comparative studies are few. Using an arthroplasty registry, we sought to assess and compare in CCKAs and RHKAs: (1) the intra-operative rates of complications, (2) the survival rates, (3) the reasons for revision, and (4) the adjusted hazard ratios for failure. MATERIALS AND METHODS 1432 constrained implants in primary TKAs performed for non-oncological indications were included: 703 RHKAs, 729 CCKAs. The two groups were comparable regarding age and gender. Kaplan-Meier curves were used to compare survival rates, multivariate analyses to assess the hazard ratios for failures. RESULTS The mean follow-up was 4.1 years (range 0-16.3) for CCKAs and 6.8 years (0-18.1) for RHKAs. The intra/peri-operative complications were similar in both the cohorts, with similar rates of femoral and tibial fractures. 10-year implant survival rates were similar in both the cohorts (91.9%, CI 95% 89.2-93.9% in RHKAs; 93.4%, CI 95% 90.3-95.6% in CCKAs). Periprosthetic infection was the most common reason for revision in the two cohorts, followed by aseptic loosening. Breakage occurred in 3 RHKAs (0.4%). CCKAs and RHKAs had a similar distribution of revision causes. Males aged less than 60 had significantly more failures, regardless the constraint degree. Unstemmed CCKAs significantly failed more than RHKAs and stemmed CCKAs. CONCLUSIONS Both modern CCKAs and RHKAs are viable long-term solutions in complex primary TKAs. More failures should be expected in males aged less than 60. LEVEL OF EVIDENCE IV, Therapeutic study.
Collapse
Affiliation(s)
- Francesco Castagnini
- Ortopedia-Traumatologia e Chirurgia Protesica e dei Reimpianti d'anca e di Ginocchio, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136, Bologna, Italy.
- DIBINEM University of Bologna, Bologna, Italy.
| | - Barbara Bordini
- Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136, Bologna, Italy
| | - Monica Cosentino
- Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136, Bologna, Italy
| | - Cristina Ancarani
- Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136, Bologna, Italy
| | - Stefano Lucchini
- Ortopedia-Traumatologia e Chirurgia Protesica e dei Reimpianti d'anca e di Ginocchio, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136, Bologna, Italy
| | - Giovanni Bracci
- Ortopedia-Traumatologia e Chirurgia Protesica e dei Reimpianti d'anca e di Ginocchio, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136, Bologna, Italy
| | - Francesco Traina
- Ortopedia-Traumatologia e Chirurgia Protesica e dei Reimpianti d'anca e di Ginocchio, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136, Bologna, Italy
- Orthopaedics and Traumatology, DIBINEM University of Bologna, Bologna, Italy
| |
Collapse
|
18
|
Ishimatsu T, Takeuchi R, Ishikawa H, Maeyama A, Osawa K, Kimura N, Yamamoto T. Clinical outcomes of hybrid closed wedge high tibial osteotomy for advanced osteoarthritis of the knee compared with total knee arthroplasty. J Orthop Surg (Hong Kong) 2022; 30:10225536221137754. [PMID: 36331144 DOI: 10.1177/10225536221137754] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
PURPOSE To evaluate clinical outcomes between hybrid closed wedge high tibial osteotomy (HCWHTO) and total knee arthroplasty (TKA) for advanced medial compartmental osteoarthritis of the knee (advanced knee OA). METHODS In more than grade 3 OA based on the Kellgren-Lawrence classification, when patients' age was less than 60 years or activity level was more than level 5 based on the UCLA activity score, 22 knees (18 patients) underwent HCWHTO. The other 22 knees (18 patients) that underwent TKA were evaluated retrospectively. Muscle strength was evaluated preoperatively and at 1 year postoperatively. The visual analogue scale (VAS) and Japanese version of the Knee injury and Osteoarthritis Outcome Score (J-KOOS) were used to evaluate clinical outcomes preoperatively and at a mean 66-months follow-up. RESULTS All postoperative muscle strength measures improved to preoperative equivalent levels in the HCWHTO group; they were significantly higher in the HCWHTO group than in the TKA group (p < .05). The VAS score and total J-KOOS significantly improved in both groups (HCWHTO, p = .001; TKA, p = .040); there were no significant differences in the scores between the groups at the final follow-up. Hybrid closed wedge HTO significantly improved the activities of daily living and sport/recreation scores, whereas TKA did not at the final follow-up. CONCLUSIONS In advanced knee OA, HCWHTO led to improved muscle strength, and its midterm clinical outcomes were equivalent to those of TKA. To postpone or even to avoid TKA, HCWHTO is considered an appropriate treatment for young and high-activity patients with advanced knee OA. LEVEL OF EVIDENCE Therapeutic Level III.
Collapse
Affiliation(s)
- Tetsuro Ishimatsu
- Department of Joint Surgery Center, 38068Yokosuka Municipal Hospital, Yokosuka city, Kanagawa, Japan.,Department of Orthopaedic Surgery, Fukuoka University Faculty of Medicine, Fukuoka, Japan
| | - Ryohei Takeuchi
- Department of Joint Surgery Center, 38068Yokosuka Municipal Hospital, Yokosuka city, Kanagawa, Japan.,Department of Joint Surgery Center, 50211Saiwaitsurumi Hospital, Yokosuka city, Kanagawa, Japan
| | - Hiroyuki Ishikawa
- Department of Joint Surgery Center, 38068Yokosuka Municipal Hospital, Yokosuka city, Kanagawa, Japan
| | - Akira Maeyama
- Department of Orthopaedic Surgery, Fukuoka University Faculty of Medicine, Fukuoka, Japan
| | - Katsunari Osawa
- Department of Joint Surgery Center, 38068Yokosuka Municipal Hospital, Yokosuka city, Kanagawa, Japan.,Department of Joint Surgery Center, 50211Saiwaitsurumi Hospital, Yokosuka city, Kanagawa, Japan
| | - Natsumi Kimura
- Department of Rehabilitation, Yokosuka Municipal Hospital, Yokosuka city, Kanagawa, Japan
| | - Takuaki Yamamoto
- Department of Orthopaedic Surgery, Fukuoka University Faculty of Medicine, Fukuoka, Japan
| |
Collapse
|
19
|
Russu O, Bloj F, Feier AM, Vunvulea V, Mogoș S, Predescu V, Pop TS. At the Edge of Orthopaedics: Initial Experience with Transarterial Periarticular Embolization for Knee Osteoarthritis in a Romanian Population. J Clin Med 2022; 11:6573. [PMID: 36362801 PMCID: PMC9655848 DOI: 10.3390/jcm11216573] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2022] [Revised: 10/25/2022] [Accepted: 11/04/2022] [Indexed: 01/03/2025] Open
Abstract
BACKGROUND Transarterial embolization (TAE) of genicular artery branches is a relatively new technique that has emerged as a promising method for delaying invasive knee surgery in patients suffering from degenerative knee osteoarthritis (OA). In mild to moderate OA, invasive major surgery can be safely postponed, and patients with major risk factors now have an alternative. Our aim was to examine the impact of TAE on clinical outcomes in individuals with degenerative knee OA over a 12-month period. METHODS A case series of 17 patients diagnosed with knee OA and treated with TAE was included in the study. Every patient was clinically evaluated at different timeframes according to the Western Ontario and McMaster Universities' arthritis index, knee injury, and osteoarthritis outcome scores, and the 36-item short-form survey (WOMAC, KOOS, and SF-36). RESULTS At the first follow-up (1 month), KOOS and WOMAC improved from 46.6 ± 13.2 (range 27.3-78.2) to 56.5 ± 13.9 (range 32.3-78.4; p = 0.023) and 49.5 ± 13.2 (range 29.3-82.3) to 59.8 ± 12.6 (range 39.3-83.5, p = 0.018), respectively. Physical SF-36 improved significantly from 42.1 ± 7.75 (range 30.3-57.3) to 50.5 ± 9.9 (range 35.6-67.9; p = 0.032). No significant changes in scores were observed at three, six, or twelve months after TAE. CONCLUSIONS TAE provided early pain reduction and considerable improvement in quality of life without complications for a consecutive sample of Romanian patients with mild to severe knee OA.
Collapse
Affiliation(s)
- Octav Russu
- Department of Orthopaedics and Traumatology, George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, 540142 Targu Mures, Romania
| | - Florin Bloj
- Ares Excellence Center, Monza Oncological Hospital, 013812 Bucharest, Romania
| | - Andrei Marian Feier
- Doctoral School, George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, 540142 Targu Mures, Romania
| | - Vlad Vunvulea
- Department of Anatomy and Embriology, George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, 540142 Targu Mures, Romania
| | - Stefan Mogoș
- Department of Orthopedics and Traumatology, Foişor Orthopaedics Hospital, 030167 Bucharest, Romania
- Ponderas Academic Hospital, 021659 Bucharest, Romania
| | - Vlad Predescu
- Ponderas Academic Hospital, 021659 Bucharest, Romania
- Department of Orthopedics and Traumatology, St Pantelimon Clinical Hospital Bucharest, University of Medicine and Pharmacy ‘Carol Davila’, 050474 Bucharest, Romania
| | - Tudor Sorin Pop
- Department of Orthopaedics and Traumatology, George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, 540142 Targu Mures, Romania
| |
Collapse
|
20
|
Szabelski J, Karpiński R, Krakowski P, Jojczuk M, Jonak J, Nogalski A. Analysis of the Effect of Component Ratio Imbalances on Selected Mechanical Properties of Seasoned, Medium Viscosity Bone Cements. MATERIALS (BASEL, SWITZERLAND) 2022; 15:5577. [PMID: 36013714 PMCID: PMC9416016 DOI: 10.3390/ma15165577] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Revised: 08/05/2022] [Accepted: 08/11/2022] [Indexed: 06/15/2023]
Abstract
The paper presents the results of experimental strength tests of specimens made of two commercially available bone cements subjected to compression, that is a typical variant of load of this material during use in the human body, after it has been used for implantation of prostheses or supplementation of bone defects. One of the factors analysed in detail was the duration of cement seasoning in Ringer's solution that simulates the aggressive environment of the human body and material degradation caused by it. The study also focused on the parameters of quantitative deviation from the recommended proportions of liquid (MMA monomer, accelerator and stabiliser) and powder (PMMA prepolymer and initiator) components, i.e., unintentional inaccuracy of component proportioning at the stage of cement mass preparation. Statistical analysis has shown the influence of these factors on the decrease in compressive strength of the cements studied, which may be of significant importance in operational practice.
Collapse
Affiliation(s)
- Jakub Szabelski
- Department of Computerization and Production Robotization, Faculty of Mechanical Engineering, Lublin University of Technology, Nadbystrzycka 36, 20-618 Lublin, Poland
| | - Robert Karpiński
- Department of Machine Design and Mechatronics, Faculty of Mechanical Engineering, Lublin University of Technology, Nadbystrzycka 36, 20-618 Lublin, Poland
| | - Przemysław Krakowski
- Chair and Department of Trauma Surgery and Emergency Medicine, Medical University of Lublin, Staszica 11, 20-081 Lublin, Poland
- Orthopaedic Department, Łęczna Hospital, Krasnystawska 52, 21-010 Leczna, Poland
| | - Mariusz Jojczuk
- Chair and Department of Trauma Surgery and Emergency Medicine, Medical University of Lublin, Staszica 11, 20-081 Lublin, Poland
| | - Józef Jonak
- Department of Machine Design and Mechatronics, Faculty of Mechanical Engineering, Lublin University of Technology, Nadbystrzycka 36, 20-618 Lublin, Poland
| | - Adam Nogalski
- Chair and Department of Trauma Surgery and Emergency Medicine, Medical University of Lublin, Staszica 11, 20-081 Lublin, Poland
| |
Collapse
|
21
|
Elmasry SS, Kahlenberg CA, Mayman DJ, Wright TM, Westrich GH, Cross MB, Imhauser CW, Sculco PK, Chalmers BP. A Mid-Level Constrained Insert Reduces Coupled Axial Rotation but Not Coronal Mid-Flexion Laxity Induced by Joint Line Elevation in Posterior-Stabilized Total Knee Arthroplasty: A Computational Study. J Arthroplasty 2022; 37:S364-S370.e1. [PMID: 35240279 DOI: 10.1016/j.arth.2022.02.089] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Revised: 02/15/2022] [Accepted: 02/21/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Surgeons may resect additional distal femur during primary posterior-stabilized (PS) total knee arthroplasty (TKA) to correct a flexion contracture. However, the resultant joint line elevation (JLE) increases mid-flexion laxity. We determined whether a mid-level constraint (MLC) insert reduced mid-flexion laxity after JLE. METHODS Six computational knee models were developed using computed tomography scans and average soft tissue properties yielding balanced extension gaps but with a 10° flexion contracture. Distal femoral resections of +2 and +4 mm were simulated with PS and MLC inserts. Varus-valgus ±10 Nm moments were applied at 30°, 45°, and 60° of flexion. Coronal laxity (the sum of varus-valgus angulation) and coupled axial rotation (the sum of internal/external rotation) were measured and compared between insert models. RESULTS At 30° of flexion, coronal laxities with the PS insert at the +2 and +4 mm resections averaged 7.9° ± 0.6° and 11.3° ± 0.6°, respectively, and decreased by 0.8° (P = .06) and 1.0° (P = .07), respectively, with the MLC insert. PS rotational laxities at the +2 and +4 mm resections averaged 11.1° ± 3.9° and 12.5° ± 4.6°, respectively, and decreased by 5.6° (P = .01) and 7.1° (P = .02), respectively, with the MLC insert. Similar patterns were observed at 45° and 60° of flexion. CONCLUSION With additional distal femoral resections to alleviate a flexion contracture, utilizing an MLC insert substantially reduced coupled axial rotation but had a minimal impact on coronal laxity compared to a PS insert. Efforts should be taken to avoid JLE in primary total knee arthroplasty as even MLC inserts may not mitigate coronal laxity.
Collapse
Affiliation(s)
- Shady S Elmasry
- Department of Biomechanics, Hospital for Special Surgery, New York, NY
| | - Cynthia A Kahlenberg
- Department of Orthopedic Surgery, Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY
| | - David J Mayman
- Department of Orthopedic Surgery, Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY
| | - Timothy M Wright
- Department of Biomechanics, Hospital for Special Surgery, New York, NY
| | | | - Michael B Cross
- Department of Orthopedic Surgery, Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY
| | - Carl W Imhauser
- Department of Biomechanics, Hospital for Special Surgery, New York, NY
| | - Peter K Sculco
- Department of Orthopedic Surgery, Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY
| | - Brian P Chalmers
- Department of Orthopedic Surgery, Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY
| |
Collapse
|
22
|
Anatone AJ, Richardson SS, Kahlenberg CA, Gausden EB, Figgie MP, Blevins JL. Decreased Implant Survival is Associated With Younger Patients Undergoing Total Knee Arthroplasty. HSS J 2022; 18:290-296. [PMID: 35645651 PMCID: PMC9097003 DOI: 10.1177/15563316211007812] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/13/2020] [Accepted: 11/20/2020] [Indexed: 02/07/2023]
Abstract
Background: Younger patients are undergoing total knee arthroplasty (TKA) at increasing rates and may face multiple revisions during their lifetimes due to mechanical complications or infections. Questions/Purposes: We sought to compare the early complication rates and revision-free implant-survival rates across age groups of patients undergoing TKA, with particular focus on implant survival in younger patients. Methods: We conducted a retrospective analysis of data taken from a national insurance database on patients who underwent primary TKA from 2007 to 2015. Kaplan-Meier curve survival analysis and log rank test were performed to evaluate revision rates in 7 age groups (younger than 40, 40-49, 50-59, 60-69, 70-79, 80-89, and 90 or more years of age). Complication rates were compared to rates in the age 60 to 79 years age groups using multiple logistic regression, controlling for baseline demographics and comorbidities. Results: There were 114,698 patients included in the analysis. Patients in the younger than 40 years, 40 to 49 years, and 50 to 59 years age groups had increased rates of early mechanical complications; 90-day readmission rates were significantly higher in those age groups as well. Revision-free implant survival at 5 years was significantly worse in patients younger than 60 years of age, particularly those less than 40 years, who had a 77% revision-free implant-survival rate at 5 years. Conclusions: Younger patients had a higher risk of early revision after TKA, as well as an increased rate of mechanical complications and readmissions at 90 days. These outcomes suggest more study is needed to better understand these discrepancies and to better guide preoperative counseling for young patients considering TKA.
Collapse
Affiliation(s)
- Alex J. Anatone
- Hospital for Special Surgery, New York,
NY, USA,Alex J. Anatone, MD, Hospital for Special
Surgery, 535 E. 70th Street, New York, NY 10021, USA.
| | | | | | | | | | | |
Collapse
|
23
|
Karpiński R, Krakowski P, Jonak J, Machrowska A, Maciejewski M, Nogalski A. Diagnostics of Articular Cartilage Damage Based on Generated Acoustic Signals Using ANN-Part I: Femoral-Tibial Joint. SENSORS 2022; 22:s22062176. [PMID: 35336346 PMCID: PMC8950358 DOI: 10.3390/s22062176] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/17/2022] [Revised: 03/02/2022] [Accepted: 03/09/2022] [Indexed: 02/01/2023]
Abstract
Osteoarthritis (OA) is a chronic, progressive disease which has over 300 million cases each year. Some of the main symptoms of OA are pain, restriction of joint motion and stiffness of the joint. Early diagnosis and treatment can prolong painless joint function. Vibroarthrography (VAG) is a cheap, reproducible, non-invasive and easy-to-use tool which can be implemented in the diagnostic route. The aim of this study was to establish diagnostic accuracy and to identify the most accurate signal processing method for the detection of OA in knee joints. In this study, we have enrolled a total of 67 patients, 34 in a study group and 33 in a control group. All patients in the study group were referred for surgical treatment due to intraarticular lesions, and the control group consisted of healthy individuals without knee symptoms. Cartilage status was assessed during surgery according to the International Cartilage Repair Society (ICRS) and vibroarthrography was performed one day prior to surgery in the study group. Vibroarthrography was performed in an open and closed kinematic chain for the involved knees in the study and control group. Signals were acquired by two sensors placed on the medial and lateral joint line. Using the neighbourhood component analysis (NCA) algorithm, the selection of optimal signal measures was performed. Classification using artificial neural networks was performed for three variants: I—open kinetic chain, II—closed kinetic chain, and III—open and closed kinetic chain. Vibroarthrography showed high diagnostic accuracy in determining healthy cartilage from cartilage lesions, and the number of repetitions during examination can be reduced only to closed kinematic chain.
Collapse
Affiliation(s)
- Robert Karpiński
- Department of Machine Design and Mechatronics, Faculty of Mechanical Engineering, Lublin University of Technology, Nadbystrzycka 36, 20-618 Lublin, Poland; (J.J.); (A.M.)
- Correspondence: (R.K.); (P.K.)
| | - Przemysław Krakowski
- Department of Trauma Surgery and Emergency Medicine, Medical University of Lublin, Staszica 11, 20-081 Lublin, Poland;
- Orthopaedic Department, Łęczna Hospital, Krasnystawska 52 str, 21-010 Łęczna, Poland
- Correspondence: (R.K.); (P.K.)
| | - Józef Jonak
- Department of Machine Design and Mechatronics, Faculty of Mechanical Engineering, Lublin University of Technology, Nadbystrzycka 36, 20-618 Lublin, Poland; (J.J.); (A.M.)
| | - Anna Machrowska
- Department of Machine Design and Mechatronics, Faculty of Mechanical Engineering, Lublin University of Technology, Nadbystrzycka 36, 20-618 Lublin, Poland; (J.J.); (A.M.)
| | - Marcin Maciejewski
- Department of Electronics and Information Technology, Faculty of Electrical Engineering and Computer Science, Lublin University of Technology, Nadbystrzycka 36, 20-618 Lublin, Poland;
| | - Adam Nogalski
- Department of Trauma Surgery and Emergency Medicine, Medical University of Lublin, Staszica 11, 20-081 Lublin, Poland;
| |
Collapse
|
24
|
Clinical outcomes of knee joint distraction combined with marrow stimulation procedures for patients with advanced knee osteoarthritis. Knee 2021; 33:342-350. [PMID: 34749126 DOI: 10.1016/j.knee.2021.10.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/08/2020] [Revised: 04/26/2021] [Accepted: 10/03/2021] [Indexed: 02/02/2023]
Abstract
BACKGROUND Knee joint distraction (KJD) has received much attention as a joint preserving surgery, especially in young patients with advanced knee osteoarthritis (OA). METHODS This study included 16 patients with advanced knee OA who underwent KJD combined with marrow stimulating techniques and were followed up for more than 2 years. The patients' clinical scores, including the Japanese Orthopaedic Association (JOA) score, Knee Injury and Osteoarthritis Outcome Score (KOOS) subscales, ROM, joint space width, and semiquantitative MRI were evaluated. The factors affecting clinical outcomes were analyzed. RESULTS Postoperatively, the JOA score and the individual scores of the KOOS subscales improved significantly (JOA score: P = 0.0028, KOOS-symptoms: P = 0.0016, -pain: P = 0.0011, -ADL: P = 0.0009, -sports/recreation: P = 0.0144, and -QOL: P = 0.0034). Although the extension of the knee joint did not change throughout the follow-up period, flexion of the joint deteriorated at the time of device removal but recovered to the preoperative level at the final follow-up. Preoperative joint space width was 2.4 ± 2.0 mm and at the final follow-up, it increased to 3.3 ± 1.5 mm, showing statistically significant improvement (P = 0.034). The postoperative semiquantitative MRI score also improved significantly (from 6.0 ± 3.0 to 42.1 ± 28.7, P = 0.0001). A high BMI was associated with a poor clinical outcome. CONCLUSION Although the effect of marrow stimulating techniques for cartilage repair was not well clarified and the complication rate was high, the clinical and radiographic outcomes showed significant improvement after KJD combined with marrow stimulating techniques in patients with advanced knee OA. However, we should be careful about suggesting this procedure in obese patients.
Collapse
|
25
|
Daud A, Safir OA, Gross AE, Kuzyk PRT. Outcomes of Bulk Fresh Osteochondral Allografts for Cartilage Restoration in the Knee. J Bone Joint Surg Am 2021; 103:2115-2125. [PMID: 34449445 DOI: 10.2106/jbjs.20.00350] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Symptomatic osteochondral defects of the knee in young patients can cause substantial disability and predispose to osteoarthritis. Fresh osteochondral allografts (FOCAs) are a treatment option for such defects. With our institution having one of the longest-running FOCA programs, we investigated the long-term outcomes of bulk FOCA in the knee, focusing on graft survivorship, function, complications, and reoperation. METHODS A total of 244 patients underwent bulk FOCA in the knee from 1972 to 2018, with a mean age of 37.8 years (range, 10 to 75 years) and a mean follow-up of 9.0 years (range, 1.0 to 29.8 years). Cartilage defects were very large and uncontained, such that they were not amenable to plug transplantation. Survivorship according to Kaplan-Meier analysis was the primary outcome, and failure was defined as conversion to total knee arthroplasty, repeat allograft, graft removal, knee arthrodesis, or amputation. Functional outcome was evaluated with use of the modified Hospital for Special Surgery (mHSS) score, and radiographic evidence of osteoarthritis was classified with use of the Kellgren-Lawrence grading scale. RESULTS Graft survivorship was 86.6% at 5 years, 73.3% at 10 years, 58.1% at 15 years, 43.7% at 20 years, 31.9% at 25 years, and 22.6% at 30 years. The most common complications were pain (14.8%), malalignment (13.9%), and stiffness (5.8%). A total of 93 grafts (38.1%) failed at a mean of 11.0 years (range, 0.5 to 34.0 years). The mean mHSS score improved significantly, from 68.7 (range, 19 to 91) preoperatively to 80.3 (range, 52 to 100) at the time of the latest follow-up (p < 0.001). Preoperative mHSS score had a negative correlation with Kellgren-Lawrence grade at the time of the latest follow-up. Multivariate analysis revealed that graft location (i.e., medial-sided or multiple grafts) and increased age were significantly negatively associated with survival. Ten-year survival was >80% in patients below 50 years old, but <40% in patients >60 years old. CONCLUSIONS Bulk FOCA provided promising long-term graft survival and functional improvement in patients <50 years old. It can delay or prevent the need for total knee arthroplasty in young patients. Older patients and patients with a medial-sided graft, or multiple grafts within the same knee, had a less favorable prognosis. LEVEL OF EVIDENCE Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Anser Daud
- Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada
| | - Oleg A Safir
- Division of Orthopaedic Surgery, Mount Sinai Hospital, Toronto, Ontario, Canada
| | - Allan E Gross
- Division of Orthopaedic Surgery, Mount Sinai Hospital, Toronto, Ontario, Canada
| | - Paul R T Kuzyk
- Division of Orthopaedic Surgery, Mount Sinai Hospital, Toronto, Ontario, Canada
| |
Collapse
|
26
|
Meyer JA, Zhu M, Cavadino A, Coleman B, Munro JT, Young SW. Infection and periprosthetic fracture are the leading causes of failure after aseptic revision total knee arthroplasty. Arch Orthop Trauma Surg 2021; 141:1373-1383. [PMID: 33515323 DOI: 10.1007/s00402-020-03698-8] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/28/2020] [Accepted: 12/03/2020] [Indexed: 10/22/2022]
Abstract
AIM The purpose of this study was to clarify the medium to long term survival of aseptic revision total knee arthroplasty (RTKAs) and identify the common modes of failure following RTKAs. MATERIALS AND METHODS A multi-center, retrospective study included all aseptic RTKAs performed at three tertiary referral hospitals between 2003 and 2016. Patients were excluded if the revision was for prosthetic joint infection (PJI) or they had previously undergone revision surgery. Minor revisions not involving the tibial or femoral components were also excluded. Demographics, surgical data and post-operative outcomes were recorded and analyzed. Survival analysis was performed and the reasons for revision failure identified. RESULTS Of 235 aseptic RTKAs identified, 14.8% underwent re-revision at mean follow-up of 8.3 years. Survivorship of RTKA was 93% at 2 years and 83% at 8 years. Average age at revision was 72.9 years (range 53-91.5). The most common reasons for failure following RTKA were periprosthetic joint infection (PJI) (40%), periprosthetic fracture (25.7%) and aseptic loosening (14.3%). Of those whose RTKA failed, the average survival was 3.33 years (8 days-11.4 years). No demographic or surgical factors were found to influence RTKA survival on univariate or multivariate analysis. CONCLUSION PJI and periprosthetic fracture are the leading causes of re-revision surgery following aseptic revision TKA. Efforts to improve outcomes of aseptic revision TKA should focus on these areas, particularly prevention of PJI.
Collapse
Affiliation(s)
- Juliette A Meyer
- School of Medicine, University of Auckland, Auckland, New Zealand
| | - Mark Zhu
- School of Medicine, University of Auckland, Auckland, New Zealand
| | - Alana Cavadino
- School of Medicine, University of Auckland, Auckland, New Zealand
| | - Brendan Coleman
- Department of Orthopaedics, Counties Manukau District Health Board, Auckland, New Zealand
| | - Jacob T Munro
- Department of Orthopaedics, Auckland District Health Board, Auckland, New Zealand
| | - Simon W Young
- School of Medicine, University of Auckland, Auckland, New Zealand. .,Department of Orthopaedics, Waitemata District Health Board, 124 Shakespeare Rd, Auckland, 0620, New Zealand.
| |
Collapse
|
27
|
High Rate of Re-Revision in Patients Less Than 55 Years of Age Undergoing Aseptic Revision Total Knee Arthroplasty. J Arthroplasty 2021; 36:2348-2352. [PMID: 33390338 DOI: 10.1016/j.arth.2020.12.008] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/09/2020] [Revised: 11/14/2020] [Accepted: 12/06/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND There are limited data on the outcomes of revision total knee arthroplasty in young patients. We sought to characterize the re-revision-free survival and risk factors for re-revision in patients less than 55 years who underwent aseptic revision TKA. METHODS We retrospectively reviewed 197 revision TKAs at a mean follow-up of 5 years. Mean age was 49 years; mean body mass index was 31 kg/m2. Twenty-seven (14%) patients had at least 1 prior revision TKA. The most common indications for revision included instability (29%), arthrofibrosis (26%), and aseptic loosening (24%). Constraint included the following: 59 posterior-stabilized (30%), 123 varus-valgus constrained (62%), and 15 hinged (8%). Components revised included the following: 93 femur/tibia (47%), 68 polyethylene-only (35%), 19 femur-only (10%), and 17 other (9%). Survivorship free from re-revision was calculated via the Kaplan-Meier method and a multivariate Cox proportional regression was utilized to identify risk factors for re-revision. RESULTS Survivorship free from any re-revision at 5 years was 80%. In the multivariate analysis, patients with a prior revision (hazard ratio [HR] = 2.78, P = .02), an isolated polyethylene exchange (HR = 3.0, P = .004), and a hinged prosthesis (HR = 3.47, P = .05) were significant risk factors for lower revision-free survival. Forty-two patients (21%) underwent re-revision, most commonly for periprosthetic joint infection (7%), instability (6%), and aseptic loosening (5%). Re-revision occurred in 18/68 (26%) patients undergoing an isolated polyethylene exchange. CONCLUSION Patients less than 55 years undergoing revision TKA have a modest 5-year revision-free survival of 80%. Patients with prior revision TKAs (HR = 2.78), hinge type prostheses (HR = 3.47), and polyethylene-only revisions (HR = 3.0) had higher revision rates.
Collapse
|
28
|
Chalmers BP, Elmasry SS, Kahlenberg CA, Mayman DJ, Wright TM, Westrich GH, Imhauser CW, Sculco PK, Cross MB. Additional distal femoral resection increases mid-flexion coronal laxity in posterior-stabilized total knee arthroplasty with flexion contracture : a computational study. Bone Joint J 2021; 103-B:87-93. [PMID: 34053287 DOI: 10.1302/0301-620x.103b6.bjj-2020-2444.r1] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
AIMS Surgeons commonly resect additional distal femur during primary total knee arthroplasty (TKA) to correct a flexion contracture, which leads to femoral joint line elevation. There is a paucity of data describing the effect of joint line elevation on mid-flexion stability and knee kinematics. Thus, the goal of this study was to quantify the effect of joint line elevation on mid-flexion laxity. METHODS Six computational knee models with cadaver-specific capsular and collateral ligament properties were implanted with a posterior-stabilized (PS) TKA. A 10° flexion contracture was created in each model to simulate a capsular contracture. Distal femoral resections of + 2 mm and + 4 mm were then simulated for each knee. The knee models were then extended under a standard moment. Subsequently, varus and valgus moments of 10 Nm were applied as the knee was flexed from 0° to 90° at baseline and repeated after each of the two distal resections. Coronal laxity (the sum of varus and valgus angulation with respective maximum moments) was measured throughout flexion. RESULTS With + 2 mm resection at 30° and 45° of flexion, mean coronal laxity increased by a mean of 3.1° (SD 0.18°) (p < 0.001) and 2.7° (SD 0.30°) (p < 0.001), respectively. With + 4 mm resection at 30° and 45° of flexion, mean coronal laxity increased by 6.5° (SD 0.56°) (p < 0.001) and 5.5° (SD 0.72°) (p < 0.001), respectively. Maximum increased coronal laxity for a + 4 mm resection occurred at a mean 15.7° (11° to 33°) of flexion with a mean increase of 7.8° (SD 0.2°) from baseline. CONCLUSION With joint line elevation in primary PS TKA, coronal laxity peaks early (about 16°) with a maximum laxity of 8°. Surgeons should restore the joint line if possible; however, if joint line elevation is necessary, we recommend assessment of coronal laxity at 15° to 30° of knee flexion to assess for mid-flexion instability. Further in vivo studies are warranted to understand if this mid-flexion coronal laxity has negative clinical implications. Cite this article: Bone Joint J 2021;103-B(6 Supple A):87-93.
Collapse
Affiliation(s)
- Brian P Chalmers
- Department of Orthopedic Surgery, Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, New York, USA
| | - Shady S Elmasry
- Department of Biomechanics, Hospital for Special Surgery, New York, New York, USA
| | - Cynthia A Kahlenberg
- Department of Orthopedic Surgery, Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, New York, USA
| | - David J Mayman
- Department of Orthopedic Surgery, Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, New York, USA
| | - Timothy M Wright
- Department of Biomechanics, Hospital for Special Surgery, New York, New York, USA
| | - Geoffrey H Westrich
- Department of Orthopedic Surgery, Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, New York, USA
| | - Carl W Imhauser
- Department of Biomechanics, Hospital for Special Surgery, New York, New York, USA
| | - Peter K Sculco
- Department of Orthopedic Surgery, Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, New York, USA
| | - Michael B Cross
- Department of Orthopedic Surgery, Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, New York, USA
| |
Collapse
|
29
|
Montes-Seguedo J, Dominguez-Lopez I, Barceinas-Sanchez J. Effect of surface texturing of UHMWPE on the coefficient of friction under arthrokinematic and loading conditions corresponding to the walking cycle. MATERIALS LETTERS 2021; 284:129039. [DOI: 10.1016/j.matlet.2020.129039] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/03/2025]
|
30
|
Lee BS, Kim TH, Bin SI, Kim JM, Kim H. Clinicoradiologic Outcomes of Medial Open-Wedge High-Tibial Osteotomy Are Equivalent in Bone-on-Bone and Non-Bone-on-Bone Medial Osteoarthritis. Arthroscopy 2021; 37:638-644. [PMID: 32998040 DOI: 10.1016/j.arthro.2020.09.033] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/29/2019] [Revised: 09/11/2020] [Accepted: 09/14/2020] [Indexed: 02/02/2023]
Abstract
PURPOSE (1) To investigate whether patients with bone-on-bone (BOB) medial OA (Ahlback grade 2) had comparable clinical improvement to those with non-BOB arthritis with remaining joint space (Ahlback grades 0/1) after medial open-wedge high tibial osteotomy (MOWHTO); (2) to determine whether the radiological results differ between these 2 groups from 1 month postoperatively to last follow-up ≥2 years later. METHODS Data of 132 knees (40 males and 92 females) who underwent MOWHTO were retrospectively reviewed. Preoperative standing anteroposterior radiographs were evaluated according to the Ahlback classification. Patients with Ahlback grade ≤1 were classified as the non-BOB group (group I, n = 88; mean age, 50.5 ± 6.3 years) and those with grade 2 as the bone-on-bone group (group II, n = 44; age, 51.6 ± 5.3 years). Clinical outcomes were assessed using Hospital for Special Surgery (HSS) and Knee Society (KS) functional scores. Medial joint space width (JSW), medial proximal tibial angle (MPTA), and mechanical alignment were considered radiological parameters. RESULTS Preoperative clinical scores were significantly lower in patients with BOB arthritis (HSS score: group I, 73.5 ± 10.7 versus group II, 69.2 ± 9.1, P = .026; KS score: group I, 72.9 ± 10.3 versus group II, 63.2 ± 11.6 points, P < .001). However, HSS and KS functional scores improved in both groups without a significant difference at a mean follow-up of 3.4 ± 2.5 and 4.1 ± 3.1 years in groups I and II, respectively (HSS score: 89.2 ± 9.5 versus 89.4 ± 7.3 points, P = .258; KS functional score: 90.1 ± 7.1 versus 87.8 ± 8.9 points, P = .105). Preoperative and postoperative medial JSWs were narrower in group II, but the JSW opening was wider in group II at 1 month after surgery and was maintained until the last follow-up (preoperative, 3.0 ± 0.9 versus 0.0 ± 0.1 mm; 1 month, 3.1 ± 1.0 versus 1.4 ± 0.8; last follow-up, 3.0 ± 1.0 versus 1.4 ± 0.9 mm; P < .001). CONCLUSION Patients with BOB medial OA achieved clinical outcomes comparable to those with remaining joint space after MOWHTO. The medial JSW showed a significant increase without OA progression during midterm follow-up in these patients. Therefore, MOWHTO can be an effective treatment choice for symptomatic improvement in middle-aged patients with severe medial OA, if there is no subchondral bone attrition. LEVEL OF EVIDENCE III, retrospective comparative study.
Collapse
Affiliation(s)
- Bum-Sik Lee
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan, College of Medicine, Seoul, Republic of Korea
| | - Tae-Hyuk Kim
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan, College of Medicine, Seoul, Republic of Korea; Gimpo Woori Hospital, Gimpo, Republic of Korea
| | - Seong-Il Bin
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan, College of Medicine, Seoul, Republic of Korea.
| | - Jong-Min Kim
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan, College of Medicine, Seoul, Republic of Korea
| | - Hanwook Kim
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan, College of Medicine, Seoul, Republic of Korea; Dongcheon Dongkang Hospital, Ulsan, Republic of Korea
| |
Collapse
|
31
|
Unicompartmental knee arthroplasty has higher revisions than total knee arthroplasty at long term follow-up: a registry study on 6453 prostheses. Knee Surg Sports Traumatol Arthrosc 2021; 29:3323-3329. [PMID: 32740877 PMCID: PMC8458185 DOI: 10.1007/s00167-020-06184-1] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/24/2020] [Accepted: 07/23/2020] [Indexed: 01/29/2023]
Abstract
PURPOSE The purpose of this study is to analyse long-term unicompartmental knee arthroplasty (UKA) focusing on survivorship, causes of failure and revision strategy. METHODS This study is a retrospective analysis of data from a regional arthroplasty registry for cases performed between 2000 and 2017. A total of 6453 UKAs were identified and the following information was analysed: demographic data, diagnosis leading to primary implant, survivorship, complication rate, causes of failure, revision strategies. UKA registry data were compared with total knee arthroplasty (TKA) registry data of 54,012 prostheses, which were implanted in the same time period. RESULTS 6453 UKAs were included in the study: the vast majority of them (84.4%) were implanted due to primary osteoarthritis followed by deformity (7.1%) and necrosis of the condyle (5.1%). When compared to TKA, UKA showed lower perioperative complication rate (0.3% compared to 0.6%) but higher revision rate (18.2% at 15 years, compared to 6.2% for TKA). No correlation was found between diagnosis leading to primary implant and prosthesis survival. The most frequent cause of failure was total aseptic loosening (37.4%), followed by pain without loosening (19.8%). Of the 620 UKAs requiring revision, 485 were revised with a TKA and 61 of them required a re-revision; on the other hand, of the 35 cases where another UKA was implanted, 16 required a re-revision. CONCLUSION UKA is associated with fewer perioperative complications but higher revision rates when compared to TKA. Its survivorship is not affected by the diagnosis leading to primary implant. Revision surgery of a failed UKA should be performed implanting a TKA, which is associated with a lower re-revision rate when compared to another UKA. LEVEL OF EVIDENCE Level 3, therapeutic study.
Collapse
|
32
|
Gangadharan R, S. Kambhampati S, Menon J. Staying safe from pitfalls in primary knee replacements. APOLLO MEDICINE 2021. [DOI: 10.4103/am.am_5_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
33
|
Krakowski P, Karpiński R, Maciejewski R, Jonak J, Jurkiewicz A. Short-Term Effects of Arthroscopic Microfracturation of Knee Chondral Defects in Osteoarthritis. APPLIED SCIENCES 2020; 10:8312. [DOI: 10.3390/app10238312] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/03/2025]
Abstract
Purpose: The purpose of this study was to estimate the effect of platelet-rich plasma (PRP) augmentation in microfractures of chondral lesions in elderly individuals. Methods: 29 patients with knee osteoarthritis were enrolled in the single-blinded randomized study. The study group consisted of 16 patients and 13 were in the control group. All surgeries were performed in the same manner. The PRP injection was made in a dry arthroscopy directly over the microfractures. The evaluation was performed preoperatively on the 6th, 12th, and 24th week following the surgery. WOMAC and Lysholm questionnaires were utilized. Results: Microfracturation showed WOMAC improvement in the PRP group (p = 0.0012) and in the control group (p = 0.0042). No statistically significant differences between the two groups (p = 0.698) have been found. Clinical improvement was noted in the first six weeks after which the effect lasted. In addition, Lysholm score showed no significant differences at the end of the follow-up between both groups (p = 0.941). Conclusions: Arthroscopic microfracture improves motor function and reduces pain in patients over 50 years old. PRP augmentation of the procedure is safe, and can accelerate and prolong the therapeutic effect of treatment. Excellent effects of the procedure are observed in the first six weeks, after which the improvement lasts.
Collapse
Affiliation(s)
- Przemysław Krakowski
- Chair and Department of Traumatology and Emergency Medicine, Medical University of Lublin, Staszica 11, 20-081 Lublin, Poland
| | - Robert Karpiński
- Department of Machine Design and Mechatronics, Faculty of Mechanical Engineering, Lublin University of Technology, Nadbystrzycka 36, 20-618 Lublin, Poland
| | - Ryszard Maciejewski
- Department of Human Anatomy, Medical University of Lublin, 20-090 Lublin, Poland
| | - Józef Jonak
- Department of Machine Design and Mechatronics, Faculty of Mechanical Engineering, Lublin University of Technology, Nadbystrzycka 36, 20-618 Lublin, Poland
| | - Andrzej Jurkiewicz
- Orthopedic Department, Łęczna Hospital, Krasnystawska 52, 21-010 Łęczna, Poland
| |
Collapse
|
34
|
Tse TST, Hui SHK, To CY, Wong MK, Tsang WL. Revision total knee arthroplasty longer term outcome and comparison between infection and aseptic loosening at mean follow-up of 10 years. JOURNAL OF ORTHOPAEDICS, TRAUMA AND REHABILITATION 2020. [DOI: 10.1177/2210491720971839] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2025] Open
Abstract
Background: Although the majority of total knee arthroplasty cases have good outcome and survival, some arthroplasty eventually required revision. While early outcomes of revision knee arthroplasty are well reported, there is relatively fewer literatures reporting on the longer term outcome of revision knee arthroplasty. This study aims to review the outcome of revision knee arthroplasty for a longer term, and also make comparison between the two common indications for revision arthroplasty of infection and aseptic loosening. Methods: This study reviews all total knee arthroplasty revision performed at a single center over a 11 year period. Of the 48 cases found, 35 cases not lost to follow-up had a mean follow-up duration of 10.6 years (SD 2.9) for aseptic loosening, and 10.1 years (SD 2.6) for infection. Data of initial arthroplasty, revision arthroplasty, demographics, follow-up outcome were obtained, analyzed and compared. Results: Revision arthroplasty due to infection had more cases that required use of varus/valgus constraints (p ∼ 0.008) and extensile surgical exposure of quadriceps snip (p ∼ 0.005) compared to aseptic loosening. The survival at 10 years for this study is 91% overall (aseptic loosening 93.3%, infection 89.3%). Infection cases had significant initial improvement for range of motion (p ∼ 0.001) and use of walking aid (p ∼ 0.04) at post-operation 1 year, but no significant differences between the infection and aseptic loosening cases at 5 years and 10 years follow-up. Comparison between the two groups on other factors including initial arthroplasty, operative details, demographics, post-operative details and X-rays showed no statistically significant difference.
Collapse
Affiliation(s)
- TST Tse
- Department of Orthopaedics and Traumatology, Pamela Youde Nethersole Eastern Hospital, Chai Wan, Hong Kong
| | - SHK Hui
- Department of Orthopaedics and Traumatology, Pamela Youde Nethersole Eastern Hospital, Chai Wan, Hong Kong
| | - CY To
- Department of Orthopaedics and Traumatology, Pamela Youde Nethersole Eastern Hospital, Chai Wan, Hong Kong
| | - MK Wong
- Department of Orthopaedics and Traumatology, Pamela Youde Nethersole Eastern Hospital, Chai Wan, Hong Kong
| | - WL Tsang
- Department of Orthopaedics and Traumatology, Pamela Youde Nethersole Eastern Hospital, Chai Wan, Hong Kong
| |
Collapse
|
35
|
Dubin JA, Westrich GH. Preoperative activity levels are an important indicator of postoperative activity in cementless TKAs. J Orthop 2020; 22:602-605. [PMID: 33299273 DOI: 10.1016/j.jor.2020.11.013] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/09/2020] [Accepted: 11/15/2020] [Indexed: 12/20/2022] Open
Abstract
Introduction It is of interest if preoperative activity level has an impact on postoperative activity level following cementless TKA. Methods This review contained 127 patients who had a preoperative Lower Extremity Activity Scale (LEAS) score ≥ to 10 (active patients) and 121 patients <10 (inactive patients). Results Postoperatively, the results showed a difference in LEAS Activity (Active 10.5 vs. Inactive 8.7, p < 0.001). Active patients had a drop in their activity level by 1.2 on the LEAS score, yet inactive patients increased by 1.6 (p < 0.0001). Conclusion Preoperative activity levels are a good indicator for postoperative activity in cementless TKA.
Collapse
Affiliation(s)
- Jeremy A Dubin
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, 535 East 70th, Street, NY, NY, 10021, USA
| | - Geoffrey H Westrich
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, 535 East 70th, Street, NY, NY, 10021, USA
| |
Collapse
|
36
|
Schwartz AM, Wilson JM, Farley KX, Bradbury TL, Guild GN. Concomitant Malnutrition and Frailty Are Uncommon, but Significant Risk Factors for Mortality and Complication Following Primary Total Knee Arthroplasty. J Arthroplasty 2020; 35:2878-2885. [PMID: 32576431 DOI: 10.1016/j.arth.2020.05.062] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/02/2020] [Revised: 05/12/2020] [Accepted: 05/25/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Total knee arthroplasty (TKA) demand continues to rise, but we are also gaining greater insight into patient risk factors for postoperative complications and excess resource utilization. There has been growing interest in frailty and malnutrition as risk factors, although they are often mistakenly used interchangeably. We aimed at identifying the incidence of their coexistence, and the magnitude of risk they confer to TKA patients. METHODS We queried the American College of Surgeons-National Surgery Quality Improvement Program database to identify 4 patient cohorts: healthy/normal serum albumin, healthy/hypoalbuminemic patients, normoalbuminemic/medically frail patients (defined by modified frailty index), and hypoalbuminemic/frail patients. We performed both univariate and multivariate analyses to quantify the risk conferred by each condition in isolation, and in coexistence. RESULTS Of 179,702 elective TKA cases from 2006 to 2018, 18.6% of patients were frail only, 3.0% were hypoalbuminemic -only, and just 1.2% were both frail and hypoalbuminemic. The raw rate of any complication was highest in frail/hypoalbuminemic patients (8.7%), 5.2% in hypoalbuminemic patients, 4.8% in frail patients, and just 3.4% in healthy patients (P < .001); the multivariate model revealed odds ratio of a complication in frail/hypoalbuminemic group of 2.40 (95% confidence interval = 1.27-1.63; P < .001). Mortality within 30 days was highest in the frail/hypoalbuminemic cohort (1.0%), and just 0.1% in healthy patients, and the multivariate model noted an odds ratio of 9.43 for these patients (95% confidence interval = 5.92-14.93; P < .001). The odds of all studied complications were highest in the frail/hypoalbuminemic group. CONCLUSION Frailty and hypoalbuminemia represent distinct conditions and are independent risk factors for a complication after TKA. Their coexistence imparts a synergistic association with the risk of post-TKA complications.
Collapse
|
37
|
Rajan PV, Ng MK, Klika A, Kamath AF, Muschler GF, Higuera CA, Piuzzi NS. The Cost-Effectiveness of Platelet-Rich Plasma Injections for Knee Osteoarthritis: A Markov Decision Analysis. J Bone Joint Surg Am 2020; 102:e104. [PMID: 32453118 DOI: 10.2106/jbjs.19.01446] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Use of platelet-rich-plasma (PRP) injections for treating knee osteoarthritis has increased over the past decade. We used cost-effectiveness analysis to evaluate the value of PRP in delaying the need for total knee arthroplasty (TKA). METHODS We developed a Markov model to analyze the baseline case: a 55-year-old patient with Kellgren-Lawrence grade-II or III knee osteoarthritis undergoing a series of 3 PRP injections with a 1-year delay to TKA versus a TKA from the outset. Both health-care payer and societal perspectives were included. Transition probabilities were derived from systematic review of 72 studies, quality-of-life (QOL) values from the Tufts University Cost-Effectiveness Analysis Registry, and individual costs from Medicare reimbursement schedules. Primary outcome measures were total costs and quality-adjusted life years (QALYs), organized into incremental cost-effectiveness ratios (ICERs) and evaluated against willingness-to-pay thresholds of $50,000 and $100,000. One and 2-way sensitivity analyses were performed as well as a probabilistic analysis varying PRP-injection cost, TKA delay intervals, and TKA outcomes over 10,000 different simulations. RESULTS From a health-care payer perspective, PRP resulted in 14.55 QALYs compared with 14.63 for TKA from the outset, with total health-care costs of $26,619 and $26,235, respectively. TKA from the outset produced a higher number of QALYs at a lower cost, so it dominated. From a societal perspective, PRP cost $49,090 versus $49,424 for TKA from the outset. The ICER for TKA from the outset was $4,175 per QALY, below the $50,000 willingness-to-pay threshold. Assuming the $728 published cost of a PRP injection, no delay time that was <10 years produced a cost-effective course. When the QOL value was increased from the published value of 0.788 to >0.89, PRP therapy was cost-effective with even a 1-year delay to TKA. CONCLUSIONS When considering direct and unpaid indirect costs, PRP injections are not cost-effective. The primary factor preventing PRP from being cost-effective is not the price per injection but rather a lack of established clinical efficacy in relieving pain and improving function and in delaying TKA. PRP may have value for higher-risk patients with high perioperative complication rates, higher TKA revision rates, or poorer postoperative outcomes. LEVEL OF EVIDENCE Economic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Prashant V Rajan
- Department of Orthopaedic Surgery, Cleveland Clinic Foundation, Cleveland, Ohio
| | | | | | | | | | | | | |
Collapse
|
38
|
Hampton M, Mansoor J, Getty J, Sutton PM. Uncemented tantalum metal components versus cemented tibial components in total knee arthroplasty: 11- to 15-year outcomes of a single-blinded randomized controlled trial. Bone Joint J 2020; 102-B:1025-1032. [PMID: 32731836 DOI: 10.1302/0301-620x.102b8.bjj-2019-1448.r1] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Aims Total knee arthroplasty is an established treatment for knee osteoarthritis with excellent long-term results, but there remains controversy about the role of uncemented prostheses. We present the long-term results of a randomized trial comparing an uncemented tantalum metal tibial component with a conventional cemented component of the same implant design. Methods Patients under the age of 70 years with symptomatic osteoarthritis of the knee were randomized to receive either an uncemented tantalum metal tibial monoblock component or a standard cemented modular component. The mean age at time of recruitment to the study was 63 years (50 to 70), 46 (51.1%) knees were in male patients, and the mean body mass index was 30.4 kg/m2 (21 to 36). The same cruciate retaining total knee system was used in both groups. All patients received an uncemented femoral component and no patients had their patella resurfaced. Patient outcomes were assessed preoperatively and postoperatively using the modified Oxford Knee Score, Knee Society Score, and 12-Item Short-Form Health Survey questionnaire (SF-12) score. Radiographs were analyzed using the American Knee Society Radiograph Evaluation score. Operative complications, reoperations, or revision surgery were recorded. A total of 90 knees were randomized and at last review 77 knees were assessed. In all, 11 patients had died and two were lost to follow-up. Results At final review all patients were between 11 and 15 years following surgery. In total, 41 of the knees were cemented and 36 uncemented. There were no revisions in the cemented group and one revision in the uncemented group for fracture. The uncemented group reported better outcomes with both statistically and clinically significant (p = 0.001) improvements in knee-specific Oxford and Knee Society scores compared with the cemented group. The global SF-12 scores demonstrated no statistical difference (p = 0.812). Uncemented knees had better radiological analysis compared with the cemented group (p < 0.001) Conclusion Use of an uncemented trabecular metal tibial implant can afford better long-term clinical outcomes when compared to cemented tibial components of a matched design. However, both have excellent survivorship up to 15 years after implantation. Cite this article: Bone Joint J 2020;102-B(8):1025–1032.
Collapse
Affiliation(s)
- Matthew Hampton
- Department of Trauma and Orthopaedics, Northern General Hospital, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, UK
| | - Junaid Mansoor
- Department of Trauma and Orthopaedics, Northern General Hospital, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, UK
| | - John Getty
- Department of Trauma and Orthopaedics, Northern General Hospital, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, UK
| | - Paul M. Sutton
- Department of Trauma and Orthopaedics, Northern General Hospital, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, UK
| |
Collapse
|
39
|
Schwartz AM, Farley KX, Guild GN, Bradbury TL. Projections and Epidemiology of Revision Hip and Knee Arthroplasty in the United States to 2030. J Arthroplasty 2020; 35:S79-S85. [PMID: 32151524 PMCID: PMC7239745 DOI: 10.1016/j.arth.2020.02.030] [Citation(s) in RCA: 414] [Impact Index Per Article: 82.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2019] [Revised: 01/22/2020] [Accepted: 02/12/2020] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND As the incidence of primary total joint arthroplasty rises in the United States, it is important to investigate how this will impact rates of revision arthroplasty. The purpose of this study was to analyze the incidence and future projections of revision total hip arthroplasty (rTHA) and revision total knee arthroplasty (rTKA) to 2030. Anticipating surgical volume will aid surgeons in designing protocols to efficiently and effectively perform rTHA/rTKA. METHODS The national inpatient sample was queried from 2002 to 2014 for all rTHA/rTKA. Using previously validated measures, Poisson and linear regression analyses were performed to project annual incidence of rTHA/rTKA to 2030, with subgroup analyses on modes of failure and age. RESULTS In 2014, there were 50,220 rTHAs and 72,100 rTKAs. From 2014 to 2030, rTHA incidence is projected to increase by between 43% and 70%, whereas rTKA incidence is projected to increase by between 78% and 182%. The 55-64 and 65-74 age groups increased in revision incidence during the study period, whereas 75-84 age group decreased in incidence. For rTKA, infection and aseptic loosening are the 2 most common modes of failure, whereas periprosthetic fracture and infection are most common for rTHA. CONCLUSION The incidence of rTHA/rTKA is projected to increase, particularly in young patients and for infection. Given the known risk factor profiles and advanced costs associated with revision arthroplasty, our projections should encourage institutions to generate revision-specific protocols to promote safe pathways for cost-effective care that is commensurate with current value-based health care trends. LEVEL OF EVIDENCE IV.
Collapse
Affiliation(s)
- Andrew M. Schwartz
- Department of Orthopaedic Surgery, Emory University School of Medicine, Atlanta, GA,Department of Orthopaedic Surgery, Emory University Orthopaedics & Spine Hospital, Tucker, GA,Reprint requests: Andrew M. Schwartz, MD, Department of Orthopaedic Surgery, Emory University School of Medicine, 59 Executive Park Drive, SE, Atlanta, GA 30329
| | - Kevin X. Farley
- Department of Orthopaedic Surgery, Emory University School of Medicine, Atlanta, GA
| | - George N. Guild
- Department of Orthopaedic Surgery, Emory University School of Medicine, Atlanta, GA,Department of Orthopaedic Surgery, Emory University Orthopaedics & Spine Hospital, Tucker, GA
| | - Thomas L. Bradbury
- Department of Orthopaedic Surgery, Emory University School of Medicine, Atlanta, GA,Department of Orthopaedic Surgery, Emory University Orthopaedics & Spine Hospital, Tucker, GA
| |
Collapse
|
40
|
Erivan R, Jacquet C, Villatte G, Ollivier M, Paprosky W. Epidemiology of painful knee after total knee arthroplasty in a tertiary care center: Assessment by decision tree. Knee 2020; 27:1049-1056. [PMID: 32305235 DOI: 10.1016/j.knee.2020.03.010] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/15/2019] [Revised: 02/18/2020] [Accepted: 03/24/2020] [Indexed: 02/02/2023]
Abstract
BACKGROUND Painful knee after arthroplasty concerns up to 21% of patients at six months. We aimed to evaluate: the application of a decision tree to explain painful knee after total knee arthroplasty (TKA), the rate of unexplained pain after complete algorithmic screening. The aim of the study was to evaluate the causes of painful TKA. Our hypothesis was that it is possible to find the cause of the pain in more than 90% of cases. METHODS A single-center retrospective study analyzed all 1130 consultations between 1 April 2017 and 31 July 2018. We included all patients consulting for unexplained chronic painful knee arthroplasty. RESULTS We included 112 knees in 105 patients as unexplained painful knee arthroplasty. Final diagnostic status was no diagnosis in seven (6.3%) cases; infection in five (4.5%); instability without real dislocation in three (2.7%); placement error in two (1.8%), due to rotational problems; loosening in 25 (22.3%): 24 (21.4%) tibial and two (1.8%) femoral; polyethylene wear in nine (8.0%); periarticular pain in 37 (33.9%): 20 with quadriceps deficiency, four with iliotibial tendinitis, four with pes bursitis, six with stiffness, and three with prepatellar bursitis); zero material problems; projected pain in 21 (18.8%); and complex regional pain syndrome in three (2.7%) cases, improved by gentle physiotherapy. CONCLUSIONS The present study was original and presents the problem in the context of everyday practice, from the clinician's point of view, with an easy-to-use decision tree that can be implemented to assess painful knee in consultation.
Collapse
Affiliation(s)
- Roger Erivan
- Université Clermont Auvergne, CHU Clermont-Ferrand, CNRS, SIGMA Clermont, ICCF, Clermont-Ferrand, France.
| | - Christophe Jacquet
- Aix-Marseille Université, CNRS, ISM UMR 7287, 13288 Marseille cedex 09, France; Institute for Locomotion, Department of Orthopedics and Traumatology, St. Marguerite Hospital, Marseille, France
| | - Guillaume Villatte
- Université Clermont Auvergne, CHU Clermont-Ferrand, CNRS, SIGMA Clermont, ICCF, Clermont-Ferrand, France
| | - Matthieu Ollivier
- Aix-Marseille Université, CNRS, ISM UMR 7287, 13288 Marseille cedex 09, France; Institute for Locomotion, Department of Orthopedics and Traumatology, St. Marguerite Hospital, Marseille, France
| | - Wayne Paprosky
- Rush University, Chicago, IL, USA; Central DuPage Hospital, Northwestern University, Winfield, IL, USA
| |
Collapse
|
41
|
Crawford DA, Adams JB, Hobbs GR, Berend KR, Lombardi AV. Higher Activity Level Following Total Knee Arthroplasty Is Not Deleterious to Mid-Term Implant Survivorship. J Arthroplasty 2020; 35:116-120. [PMID: 31471181 DOI: 10.1016/j.arth.2019.07.044] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/19/2019] [Revised: 07/09/2019] [Accepted: 07/31/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The impact of a patient's activity level following total knee arthroplasty (TKA) remains controversial, with some surgeons concerned about increased polyethylene wear, aseptic loosening, and revisions. The purpose of this study is to report on implant survivorship and outcomes of high activity patients compared to low activity patients after TKA. METHODS A retrospective review identified 1611 patients (2038 knees) that underwent TKA with 5-year minimum follow-up. Patients were divided in 2 groups based on their University of California Los Angeles (UCLA) activity level: low activity (LA) (UCLA ≤5) and high activity (HA) (UCLA ≥6). Outcomes included range of motion, Knee Society scores, complications, and reoperations. Parametric survival analysis was performed to evaluate the significance of activity level on survivorship while controlling for age, gender, preoperative pain, Knee Society clinical scores, Knee Society functional scores, and body mass index (BMI). RESULTS Mean follow-up was 11.4 years (range 5.1-15.9). The LA group had significantly more female patients, were older, had higher BMI, and had lower functional scores preoperatively (all with P < .001). The HA group had significantly higher improvements in Knee Society scores (P < .001) and pain postoperatively (P < .001). Revisions were performed in 4% of the LA group and 1.7% knees of the HA group (P = .003). After controlling for age, gender, preoperative pain, Knee Society clinical scores, Knee Society functional scores, and BMI, a higher postoperative activity level remained a significant factor for improved survivorship with an odds ratio of 2.4 (95% confidence interval 1.2-4.7, P = .011). The all-cause 12-year survivorship was 98% for the HA group and 95.3% for the LA group (P = .003). The aseptic 12-year survivorship was 98.4% for the HA group and 96.3% for the LA group (P = .02). CONCLUSION Highly active patients had increased survivorship at 5-year minimum follow-up compared to lower activity patients after TKA. Patient activity level after TKA may not need to be limited with modern implants.
Collapse
Affiliation(s)
| | | | - Gerald R Hobbs
- Department of Statistics, West Virginia University, Morgantown, WV
| | - Keith R Berend
- Joint Implant Surgeons, Inc., New Albany, OH; Mount Carmel Health System, New Albany, OH
| | - Adolph V Lombardi
- Joint Implant Surgeons, Inc., New Albany, OH; Mount Carmel Health System, New Albany, OH; Department of Orthopaedics, The Ohio State University Wexner Medical Center, Columbus, OH
| |
Collapse
|
42
|
Charette RS, Sloan M, DeAngelis RD, Lee GC. Higher Rate of Early Revision Following Primary Total Knee Arthroplasty in Patients Under Age 55: A Cautionary Tale. J Arthroplasty 2019; 34:2918-2924. [PMID: 31353252 DOI: 10.1016/j.arth.2019.06.060] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/08/2019] [Revised: 06/23/2019] [Accepted: 06/27/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND There has been an increased number of total knee arthroplasties (TKAs) performed in young and active patients. Although improved materials have decreased the likelihood of early catastrophic wear, concerns remain with the performance and survivorship of TKA implants in this patient population. The purpose this study is to evaluate perioperative complications, patient-reported outcomes, and implant survivorship of TKAs performed in patients under age 55. METHODS We retrospectively reviewed 4259 primary TKAs performed over a 4-year period. There were 741 TKAs in patients under age 55. The primary outcome of interest was rate of revision at 30 days, 1, 2, and 5-year time points. Secondary outcomes included postoperative transfusion rate, length of stay, rate of deep vein thrombosis/pulmonary embolism, need for manipulation under anesthesia, readmission and reoperation within 30 days, as well as patient-reported outcomes. RESULTS There were 3518 patients over 55 years and 741 patients under 55 years. Overall, 175 patients required revision (4.1%). Patients under 55 years had significantly higher cumulative revision rate at 1 (3.4% vs 1.8%, P < .001), 2 (5.0% vs 2.4%, P < .001), and 5 years (7.3% vs 3.7%, P < .001). Patients under 55 years had a higher rate of early reoperation. Patients over 55 years required more transfusions and suffered a higher rate of early deep vein thrombosis. Patients over 55 years had significantly greater improvements in Patient Reported Outcome Measurement Information System Global 10 Physical scores at 6 months postoperatively compared to patients under 55 years. CONCLUSIONS Despite improvements in TKA implants, young and active patients remained at higher risk of early revision compared to older patients. The data should be used to counsel young prospective TKA patients about the early risk of reoperation and non-wear-related complications.
Collapse
Affiliation(s)
- Ryan S Charette
- Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA
| | - Matthew Sloan
- Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA
| | - Ryan D DeAngelis
- Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA
| | - Gwo-Chin Lee
- Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA
| |
Collapse
|
43
|
Jonak J, Karpinski R, Machrowska A, Krakowski P, Maciejewski M. A preliminary study on the use of EEMD-RQA algorithms in the detection of degenerative changes in knee joints. IOP CONFERENCE SERIES: MATERIALS SCIENCE AND ENGINEERING 2019; 710:012037. [DOI: 10.1088/1757-899x/710/1/012037] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/03/2025]
Abstract
Abstract
Degenerative changes, according to world literature, are one of the key reasons for disability, especially in the elderly population. Diagnosis and monitoring of the disease consist mainly in clinical examination, bedside interviews and imaging. However, during the healing process, there is currently no tool for fast, cheap, easily available and diagnostics that would be free from ionising radiation and that would enable evaluation of the course of the disease. Therefore, the scientific community is searching for new diagnostic methods, with the potential for wide application in medicine. Registration and analysis of knee joint vibration signals presents a chance for more accurate and faster diagnostics. The method is capable of detecting damage at an early stage, while specifying the selection of optimal treatment methods. Therefore, it seems crucial to develop methods of analysis appropriate for the nature of tested signals. The quality of low-frequency natural waveforms can be improved by filtration in selected bands, eliminating existing artefacts. This paper presents an application of the EEMD-RQA algorithm in the detection of degenerative changes in knee joints. Pre-processing in the form of filtration gives the opportunity to pre-test the usefulness of the algorithm RQA in the ability to create/subsequent development of indicators describing the condition of the joint surfaces examined without the need for surgical intervention.
Collapse
|
44
|
Miller RE, Scanzello CR, Malfait AM. An emerging role for Toll-like receptors at the neuroimmune interface in osteoarthritis. Semin Immunopathol 2019; 41:583-594. [PMID: 31612243 DOI: 10.1007/s00281-019-00762-3] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2019] [Accepted: 09/09/2019] [Indexed: 12/31/2022]
Abstract
Osteoarthritis (OA) is a chronic progressive, painful disease of synovial joints, characterized by cartilage degradation, subchondral bone remodeling, osteophyte formation, and synovitis. It is now widely appreciated that the innate immune system, and in particular Toll-like receptors (TLRs), contributes to pathological changes in OA joint tissues. Furthermore, it is now also increasingly recognized that TLR signaling plays a key role in initiating and maintaining pain. Here, we reviewed the literature of the past 5 years with a focus on how TLRs may contribute to joint damage and pain in OA. We discuss biological effects of specific damage-associated molecular patterns (DAMPs) which act as TLR ligands in vitro, including direct effects on pain-sensing neurons. We then discuss the phenotype of transgenic mice that target TLR pathways, and provide evidence for a complex balance between pro- and anti-inflammatory signaling pathways activated by OA DAMPs. Finally, we summarize clinical evidence implicating TLRs in OA pathogenesis, including polymorphisms and surrogate markers of disease activity. Our review of the literature led us to propose a model where multi-directional crosstalk between connective tissue cells (chondrocytes, fibroblasts), innate immune cells, and sensory neurons in the affected joint may promote OA pathology and pain.
Collapse
Affiliation(s)
- Rachel E Miller
- Division of Rheumatology, Department of Internal Medicine, Rush University Medical Center, 1611 W Harrison Street, Chicago, IL, 60612, USA
| | - Carla R Scanzello
- Section of Rheumatology and Translational Musculoskeletal Research Center, Corporal Michael J. Crescenz Veterans Affairs Medical Center & Division of Rheumatology, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA, 19104, USA
| | - Anne-Marie Malfait
- Division of Rheumatology, Department of Internal Medicine, Rush University Medical Center, 1611 W Harrison Street, Chicago, IL, 60612, USA.
| |
Collapse
|
45
|
Castagnini F, Bordini B, Tassinari E, Stea S, Ancarani C, Traina F. Delta-on-Delta Ceramic Bearing Surfaces in Revision Hip Arthroplasty. J Arthroplasty 2019; 34:2065-2071. [PMID: 31160152 DOI: 10.1016/j.arth.2019.04.068] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/05/2019] [Revised: 04/24/2019] [Accepted: 04/29/2019] [Indexed: 02/07/2023] Open
Abstract
BACKGROUND Fourth-generation ceramic-on-ceramic couplings were developed to improve ceramic toughness and strength. Encouraging outcomes in primary total hip arthroplasty were reported. This coupling was proposed as an attractive option even in the case of revision procedures, particularly in younger patients with a longer life expectancy. However, the pertinent literature is scarce. Thus, a registry study was conducted to investigate the midterm survival rates and reasons for re-revision of the fourth-generation ceramic-on-ceramic bearing surfaces in revision hip arthroplasties. METHODS A total of 327 revision implants (all the components were exchanged) with BIOLOX Delta couplings were investigated using the regional orthopedic registry RIPO. The demographics, the survival rates, and the reasons for re-revision were assessed. Revisions with bearings other than Delta were compared. RESULTS Delta bearings achieved a survival rate of 90.5% at 7 years, with stable results. Twenty-six (8%) re-revisions occurred at a mean follow-up of 4.1 years. And 2.8% of the re-revisions were due to recurrent dislocations; 1.5% of the cases were due to cup aseptic loosening. Septic loosening occurred in 1.6% of the cases. No ceramic fractures were reported. When compared to revisions with bearings other than Delta-on-Delta, Delta coupling cohort achieved similar performances at 5 and 7 years. Lower, nonsignificant rates of aseptic and septic loosening were reported in Delta cohort. CONCLUSION Delta-on-Delta couplings demonstrated to be reliable bearing surfaces in revision settings at a midterm follow-up. Clinical studies and longer follow-ups are required to investigate potential adverse effects, like squeaking and fractures, and confirm these preliminary findings. LEVEL OF EVIDENCE Level III, therapeutic study.
Collapse
Affiliation(s)
- Francesco Castagnini
- Ortopedia-Traumatologia e Chirurgia protesica e dei reimpianti d'anca e di ginocchio, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Barbara Bordini
- Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Enrico Tassinari
- Ortopedia-Traumatologia e Chirurgia protesica e dei reimpianti d'anca e di ginocchio, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Susanna Stea
- Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Cristina Ancarani
- Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Francesco Traina
- Ortopedia-Traumatologia e Chirurgia protesica e dei reimpianti d'anca e di ginocchio, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| |
Collapse
|
46
|
Busanelli L, Castagnini F, Bordini B, Stea S, Calderoni PP, Toni A. The biological acetabular reconstruction with bone allografts in hip revision arthroplasty. Musculoskelet Surg 2019; 103:173-179. [PMID: 30328029 DOI: 10.1007/s12306-018-0573-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2018] [Accepted: 10/10/2018] [Indexed: 02/07/2023]
Abstract
BACKGROUND Reconstructions in case of acetabular bone loss in hip revision arthroplasty are challenging. A few techniques have been proposed, with inconstant outcomes. Biological reconstructions using bone allografts may address the acetabular bone loss and restore the hip anatomy. Aim of this work was the description of the surgical technique and the evaluation of the outcomes using a regional arthroplasty register. MATERIALS AND METHODS Minor or massive bone allografting was performed in hip revision arthroplasties in a tertiary center. Bulk allografts were used in severe acetabular bone losses. Fresh-frozen femoral heads were impacted in the bone cavity and porous cups were implanted; multihole sockets were used when necessary. In DeLee A zone, no grafts were used in order to reduce overstress graft resorption. The results were evaluated using a regional arthroplasty register, and a comparison with revisions without bone grafts was performed investigating re-revision rates and reasons for further revisions. RESULTS At 10 years, acetabular revisions with bone allografts achieved a similar survival rate than revisions without bone grafts. The re-revisions occurred more frequently in revisions without bone allografts (10.8 vs. 9.7%). In the allograft cohort, septic loosening was lower (0.3 vs. 2.6%), whereas a higher rate of aseptic cup loosening was experienced (2.7 vs. 1.4%). CONCLUSIONS Bone allografts may provide a good restoration of the acetabular bone stock and the hip biomechanics. Septic loosening does not seems a major concern, whereas a higher rate of aseptic cup loosening should be expected when bone grafts are used.
Collapse
Affiliation(s)
- L Busanelli
- Ortopedia-Traumatologia e Chirurgia protesica e dei reimpianti d'anca e di ginocchio, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136, Bologna, Italy
| | - F Castagnini
- Ortopedia-Traumatologia e Chirurgia protesica e dei reimpianti d'anca e di ginocchio, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136, Bologna, Italy.
| | - B Bordini
- Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136 Bologna, Italy
| | - S Stea
- Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136 Bologna, Italy
| | - P P Calderoni
- Ortopedia-Traumatologia e Chirurgia protesica e dei reimpianti d'anca e di ginocchio, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136, Bologna, Italy
| | - A Toni
- Ortopedia-Traumatologia e Chirurgia protesica e dei reimpianti d'anca e di ginocchio, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136, Bologna, Italy
| |
Collapse
|
47
|
Ponzio DY, Chiu YF, Salvatore A, Lee YY, Lyman S, Windsor RE. An Analysis of the Influence of Physical Activity Level on Total Knee Arthroplasty Expectations, Satisfaction, and Outcomes: Increased Revision in Active Patients at Five to Ten Years. J Bone Joint Surg Am 2018; 100:1539-1548. [PMID: 30234618 DOI: 10.2106/jbjs.17.00920] [Citation(s) in RCA: 45] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
UNLABELLED This article was updated on September 19, 2018, because of a previous error. On page 1546, in the section titled "Discussion," the sentence that had read "Although a significant improvement was found in the vast majority of the inactive group, surprisingly, a majority of the active group (72.7%) reported a decrease in their activity levels below their baseline at 5 to 10 years postoperatively." now reads "Although a significant improvement was found in the vast majority of the inactive group, surprisingly, a majority of the active group (72.7%) reported no change or a decrease in their activity levels below their baseline at 5 to 10 years postoperatively." BACKGROUND Patients undergoing total knee arthroplasty expect pain relief, functional improvement, and a return to physical activity. The objective of this study was to determine the impact of patients' baseline physical activity level on preoperative expectations, postoperative satisfaction, and clinical outcomes in patients undergoing total knee arthroplasty. METHODS Using an institutional registry from 2007 to 2012, we retrospectively identified patients who underwent a unilateral primary total knee arthroplasty for osteoarthritis and completed a preoperative Lower Extremity Activity Scale (LEAS), a Hospital for Special Surgery Knee Replacement Expectations Survey (HSS-KRES), and a Knee injury and Osteoarthritis Outcome Score (KOOS) evaluation in addition to 2-year KOOS and satisfaction evaluations. Active patients were defined by an LEAS level of 13 to 18. Active patients (n = 1,008) were matched to inactive patients (n = 1,008) by age, sex, body mass index, and comorbidities. The cohorts were compared with regard to the association of expectations with KOOS and satisfaction, the change in LEAS level from baseline to 2 years, complications, and revision surgical procedures. Multivariable analyses identified predictors of satisfaction, KOOS, and revision surgical procedures. RESULTS Significantly more active patients (68.2%) expected to be back to normal with regard to the ability to exercise and participate in sports compared with inactive patients (55.5%; p < 0.0001). Although overall satisfaction was equivalent, active patients were more commonly very satisfied with regard to the ability to do recreational activities (67.2% compared with 57.7%; p = 0.001). There were no associations between expectations and satisfaction or outcomes. Only the inactive patient group improved in activity level at 2 years. At 2 years, 69.5% of the inactive patients and 27.3% of the active patients improved upon their baseline activity levels (p < 0.0001). Complications rates were similar. The revision rate was higher for active patients (3.2%) compared with inactive patients (1.6%) at 5 to 10 years postoperatively (p = 0.019). CONCLUSIONS At 2 years following total knee arthroplasty, inactive patients improved from baseline activity levels and active patients did not. Active patients had an elevated revision risk. Therefore, active patients should be carefully counseled regarding total knee arthroplasty to give them an understanding of its limitations and the potential risk of future revision. LEVEL OF EVIDENCE Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Danielle Y Ponzio
- Rothman Institute at Thomas Jefferson University, Egg Harbor Township, New Jersey
| | - Yu-Fen Chiu
- Adult Reconstruction & Joint Replacement Division, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY
| | - Anthony Salvatore
- Adult Reconstruction & Joint Replacement Division, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY
| | - Yuo-Yu Lee
- Adult Reconstruction & Joint Replacement Division, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY
| | - Stephen Lyman
- Adult Reconstruction & Joint Replacement Division, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY
| | - Russell E Windsor
- Adult Reconstruction & Joint Replacement Division, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY
| |
Collapse
|
48
|
Projective geometric model for automatic determination of X-ray-emitting source of a standard radiographic system. Comput Biol Med 2018; 99:209-220. [PMID: 29957378 DOI: 10.1016/j.compbiomed.2018.06.016] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2018] [Revised: 06/04/2018] [Accepted: 06/17/2018] [Indexed: 01/14/2023]
Abstract
BACKGROUND AND OBJECTIVE Currently, many orthopedic operations are planned by analyzing X-rays. The exact position of the focus is needed to calculate the real size of an object that is represented in conical projection, although in practice, this position is difficult to determine using current X-ray commercial systems. In this paper, a new geometric model is proposed in order to determine accurately, practically, and economically the location of the emitting source of commercial imaging systems using a single standard X-ray image. METHOD The method requires a specific reference locator object to be positioned in the visual field of radiographic image. Because this object cannot implement ideal geometric points, but instead works with small spheres, it was necessary to experimentally validate the proposed methodology. The implemented software that was developed to validate the model was used in four series of tests. In these tests, we studied the influence on the final result of: 1. the selection of a specific set of markers in radiography, 2. the focus position variation in relation to radiograph and 3. the possible rotated angle of locator object about Z axis. RESULTS The results for 164 tests that were performed with this software showed that the expected error for 99.5% of values ranges with maximum error of [-0.35%, +0.39%], which shows that the model is independent of the design of locator object and its position and orientation in the radiographic field. The software used to validate the proposed model has been found useful to verify its reliability, effectiveness, ease of implementation, and accuracy. CONCLUSIONS This model is effective to calculate the precise position of the X-ray focus of any standard radiographic system accurately.
Collapse
|
49
|
Tsai HC, Chen TL, Chen YP, Chen RM. Traumatic osteoarthritis-induced persistent mechanical hyperalgesia in a rat model of anterior cruciate ligament transection plus a medial meniscectomy. J Pain Res 2017; 11:41-50. [PMID: 29317848 PMCID: PMC5743113 DOI: 10.2147/jpr.s154038] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
Background Osteoarthritis (OA) is a degenerative joint disease characterized by progressive cartilage degeneration, subchondral bone changes, osteophyte formation, and synovitis. A major symptom is pain that is triggered by peripheral and central changes within the pain pathways. Some surgery-induced joint instability rat models of OA were described to mimic traumatic OA. Several behavioral tests were developed to access OA-induced pain. However, follow-up in most studies usually only occurred for about 4 weeks. Since traumatic OA is a chronic disease which gradually develops after trauma, the pattern of pain might differ between early and late stages after the trauma. Purpose To observe the time-dependent development of hypersensitivity after traumatic OA and to determine the best timing and methods to investigate traumatic OA-induced pain. Methods Anterior cruciate ligament transection plus medial meniscectomy was used to induce traumatic OA in Sprague-Dawley rats. Traumatic OA-induced pain was evaluated using four different behavioral tests for 15 weeks. Results A significant difference in mechanical hypersensitivity developed throughout the observational period. It was worst in the first 3 weeks after the operation, then became less significant after 5 weeks but persisted. There were no differences in thermal hyperalgesia or motor coordination. Conclusion Traumatic OA induced mechanical hyperalgesia but did not cause thermal hyperalgesia or influence motor coordination. Furthermore, to investigate chronic pain induced by OA, the observational period should be at least 5 weeks after the intervention. These findings may help in further research and improve our understanding of traumatic OA-induced pain mechanisms.
Collapse
Affiliation(s)
- Hsiao-Chien Tsai
- Graduate Institute of Medical Sciences, College of Medicine, Taipei Medical University, Taipei, Taiwan.,Department of Anesthesiology, Taipei Medical University Hospital, Taipei Medical University, Taipei, Taiwan.,Department of Anesthesiology, School of Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan
| | - Ta-Liang Chen
- Department of Anesthesiology, Taipei Medical University Hospital, Taipei Medical University, Taipei, Taiwan.,Department of Anesthesiology, School of Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan.,Anesthesiology and Health Policy Research Center, Taipei Medical University Hospital, Taipei Medical University, Taipei, Taiwan
| | - Yu-Pin Chen
- Department of Orthopedic Surgery, Wan Fang Hospital, Taipei Medical University, Taipei, Taiwan
| | - Ruei-Ming Chen
- Graduate Institute of Medical Sciences, College of Medicine, Taipei Medical University, Taipei, Taiwan.,Department of Anesthesiology, School of Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan.,Comprehensive Cancer Center, Taipei Medical University, Taipei, Taiwan
| |
Collapse
|