1
|
Breuer R, Fiala R, Hartenbach F, Pollok F, Huber T, Strasser-Kirchweger B, Rath B, Trieb K. Long term follow-up of a completely metal free total knee endoprosthesis in comparison to an identical metal counterpart. Sci Rep 2024; 14:20958. [PMID: 39251687 PMCID: PMC11384776 DOI: 10.1038/s41598-024-71256-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2024] [Accepted: 08/26/2024] [Indexed: 09/11/2024] Open
Abstract
Aseptic loosening is a feared and not yet fully-understood complication of total knee arthroplasty (TKA). Hypersensitivity reactions may be the underlying cause within some susceptible patients. Metal-free implants have been developed as a possible solution. The aim of this prospective, observational long-term study was the assessment of a completely metal-free ceramic knee replacement system compared to its identical metal counterpart 8 years after implantation, conducted as a follow-up of a previous report. A total of 88 patients (mean age 69 years) were enrolled in this prospective, observational long-term 8-year follow-up study. The "ceramic group" with a completely metal-free total knee replacement system was compared to the "conventional group" with an identical metal TKA system at the final follow-up. Clinical assessment included Knee Society Score (KSS), Oxford Knee Score (OKS), European Quality of Life 5 Dimensions 3 Level Version (EQ-5D-L), European Quality of Life 5 Dimension Visual Analogue Scale (EQ-VAS) and High Activity Arthroplasty Score (HAAS) as well as perioperative or postoperative complications and need for revision. The tibial/femoral positioning, signs of periprosthetic fissures/fractures or radiolucent lines were documented radiographically. All postoperative clinical scores in the ceramic group primarily improved from baseline to 4-year follow-up, but then decreased at the final 8-year follow-up. At the final follow-up, statistically non-significant differences were found in comparison of both groups for the KSS (ceramic: 166 ± 31, conventional: 162 ± 29; p > 0.05), OKS (ceramic: 37, conventional: 39; p > 0.05), EQ-VAS (ceramic: 77 ± 17, conventional: 72 ± 18; p > 0.05), and HAAS (ceramic: 8.29 ± 3.32, conventional: 9.28 ± 4.44; p > 0.05). A significant difference was found for EQ-5D-L (ceramic: 0.819 ± 0.284, conventional: 0.932 ± 0.126; p ≤ 0.05). Progressive radiolucent lines have been found around the uncemented tibial stem (0.8 mm at initial diagnosis (mean 19 months); 1.3 mm at 4-year follow-up; 1.6 mm at 8-year follow-up) without any clinical signs of loosening. One revision surgery was performed after a traumatic polyethylene inlay-breakage. No allergic reactions could be detected. The used ceramic TKA system meets the functional performance standards of an established identical metal TKA system after an 8-year follow-up period, offering a safe option for patients with prior hypersensitivity reactions to metallic materials. Full cementation of ceramic components is recommended.
Collapse
Affiliation(s)
- Robert Breuer
- Department of Orthopedics and Trauma Surgery, Klinik Donaustadt, 1220, Vienna, Austria
| | - Rainer Fiala
- Department of Orthopedics and Trauma Surgery, Klinik Donaustadt, 1220, Vienna, Austria
| | - Florian Hartenbach
- Department of Orthopedics, Klinikum Wels-Grieskirchen, 4600, Wels, Austria
| | - Florian Pollok
- Department of Orthopedics, Klinikum Wels-Grieskirchen, 4600, Wels, Austria
| | - Thorsten Huber
- Department of Orthopedics, Klinikum Wels-Grieskirchen, 4600, Wels, Austria
| | | | - Bjoern Rath
- Department of Orthopedics, Klinikum Wels-Grieskirchen, 4600, Wels, Austria
| | - Klemens Trieb
- Department of Orthopedics, Paracelsus Medical University, 5020, Salzburg, Austria.
- Division for Orthopaedics and Traumatology, Center for Clinical Medicine, Danube Private University, 3500, Krems, Austria.
| |
Collapse
|
2
|
Yao K, Chen Y. Comprehensive evaluation of risk factors for aseptic loosening in cemented total knee arthroplasty: A systematic review and meta-analysis. J Exp Orthop 2024; 11:e12095. [PMID: 39035847 PMCID: PMC11260281 DOI: 10.1002/jeo2.12095] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/07/2024] [Accepted: 06/03/2024] [Indexed: 07/23/2024] Open
Abstract
Purpose Aseptic loosening is the most common cause for revisions after total knee arthroplasty (TKA). Despite many studies exploring various risk factors associated with aseptic loosening, findings often present inconsistencies. To address this, we conducted a thorough review of the literature to identify and analyse these risk factors in cemented TKA. Additionally, we performed a meta-analysis to reconcile the divergent conclusions observed across studies. Methods We searched PubMed, Web of Science and Embase from 1996 up to 2024 and evaluated the quality of the included literature. Seventy-four studies were included to assess the association of BMI, diabetes, high physical activity (HPA), osteoporosis, rheumatoid arthritis (RA), cement material and implant design. Twenty-nine studies were used to calculate relative risk and CIs (using the random effects theory) and study heterogeneity for six different risk factors (BMI, diabetes, HPA level, cement material, polyethylene and implant design). Results Patients with diabetes are eight times more likely to experience aseptic loosening compared to those without diabetes (RR = 9.18, 95% CI: 1.80-46.77, p < 0.01). The use of tibial stem extension or highly crosslinked polyethylene can help reduce the incidence of aseptic loosening. However, we did not identify BMI, HPA, osteoporosis, RA, the use of high-viscosity cement and the utilization of mobile-bearing designs as risk factors for aseptic loosening post-cemented TKA. Conclusions Patients with diabetes undergoing TKA should be counselled regarding their potential increased risk of aseptic loosening. The use of tibial stem extensions and HXLPE can mitigate the incidence of aseptic loosening in cemented TKA. However, given a limited number of studies were included in the meta-analysis, we believe that higher-level studies are necessary to clearly identify other risk factors. Level of Evidence Level III.
Collapse
Affiliation(s)
- Kaiyi Yao
- Faculty of Medicine and Health SciencesGhent UniversityGhentBelgium
| | - Yao Chen
- Department of Applied Mathematics, Computer Science and StatisticsGhent UniversityGhentBelgium
- Department of Morphology, Imaging, Orthopedics, Rehabilitation and NutritionGhent UniversityMerelbekeBelgium
- DIGPCR‐Ghent University Digital PCR ConsortiumGhent UniversityMerelbekeBelgium
| |
Collapse
|
3
|
Sohn S, Koh IJ, Kim MS, Choi KY, Lim DS, In Y. Mobile-Bearing has no Benefit Over Fixed-Bearing Total Knee Arthroplasty in Joint Awareness and Crepitus: A Randomized Controlled Trial. J Arthroplasty 2023; 38:78-84. [PMID: 35934188 DOI: 10.1016/j.arth.2022.07.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/03/2022] [Revised: 07/26/2022] [Accepted: 07/28/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Given higher component conformity, rotational availability of polyethylene insert, and more physiologic patellofemoral tracking, mobile-bearing (MB) total knee arthroplasty (TKA) is supposed to offer advantages in joint perception and crepitus. The purpose of this study was to investigate whether MB TKA offers superior outcomes over fixed-bearing (FB) TKA in terms of joint awareness and crepitus. METHODS This prospective, randomized, controlled trial included 49 FB and 49 MB TKAs that shared the same posterior-stabilized femoral component. Primary outcomes included joint awareness assessed with the Forgotten Joint Score and crepitus graded according to severity and sound at 3 years postoperatively. Secondary outcomes were the range of motion, the Knee Society Score, Western Ontario and McMaster Universities Osteoarthritis Index, component position, and joint line level on radiographs. RESULTS The Forgotten Joint Score showed no significant difference between the FB (67 points; range, 0-100) and MB groups (63 points; range, 13-100) (P = .440). For crepitus, no significant differences were found in the overall incidence rate (FB group, 18%; MB group, 12%; P = .386) and grade (grade 1, 6 versus 5; grade 2, 2 versus 1; grade 3, 1 versus 0, respectively). There were no significant differences in range of motion, Knee Society Score, and Western Ontario and McMaster Universities Osteoarthritis Index, as well as radiographic outcomes between the two groups (all, P > .05). CONCLUSION MB TKA offers no benefits in terms of joint awareness and crepitus compared with FB TKA at mean 3 years postoperatively. The theoretical advantages of MB TKA have yet to be demonstrated in practice, leaving the selection of bearing type to the surgeon's judgment. LEVEL OF EVIDENCE Level II.
Collapse
Affiliation(s)
- Sueen Sohn
- Department of Orthopaedic Surgery, Inje University Sanggye Paik Hospital, College of Medicine, Inje University, Seoul, Republic of Korea
| | - In Jun Koh
- Department of Orthopaedic Surgery, Eunpyeong St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Man Soo Kim
- Department of Orthopaedic Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Keun Young Choi
- Department of Orthopaedic Surgery, Eunpyeong St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Da Sol Lim
- Department of Orthopaedic Surgery, Inje University Sanggye Paik Hospital, College of Medicine, Inje University, Seoul, Republic of Korea
| | - Yong In
- Department of Orthopaedic Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| |
Collapse
|
4
|
Shatrov J, Sappey-Marinier E, Kafelov M, Gunst S, Batailler C, Servien E, Lustig S. Similar outcomes including maximum knee flexion between mobile bearing condylar-stabilised and fixed bearing posterior-stabilised prosthesis: a case control study. J Exp Orthop 2022; 9:17. [PMID: 35169966 PMCID: PMC8847635 DOI: 10.1186/s40634-022-00456-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/29/2022] [Accepted: 02/11/2022] [Indexed: 11/12/2022] Open
Abstract
Purpose Prosthesis design influences stability in total knee arthroplasty and may affect maximum knee flexion. Posterior-stabilised (PS) and condylar-stabilised (CS) designed prosthesis do not require a posterior-cruciate ligament to provide stability. The aim of the current study was to compare the range of motion (ROM) and clinical outcomes of patients undergoing cemented total knee arthroplasty (TKA) using either a PS or CS design prosthesis. Methods A total of 167 consecutive primary TKAs with a CS bearing (mobile deep-dish polyethylene) were retrospectively identified and compared to 332 primary TKA with a PS constraint, with similar design components from the same manufacturer. Passive ROM was assessed at last follow-up with use of a handheld goniometer. Clinical scores were assessed using Patient-Reported Outcome Measures (PROMs); International Knee Society (IKS) knee and function scores and satisfaction score. Radiographic assessment was performed pre and post operatively consisting of mechanical femorotibial angle (mFTA), femoral and tibial mechanical angles measured medially (FMA and TMA, respectively) on long leg radiographs, tibial slope and patella height as measured by the Blackburne-Peel index (BPI). Results Both groups had a mean follow-up of 3 years (range 2–3.7 years). Mean post-operative maximum knee flexion was 117° ± 4.9° in the PS group and 119° ± 5.2° in the CS group (p = 0.29). Postoperative IKS scores were significantly improved in both groups compared to preoperative scores (p < 0.01). The mean IKS score in the PS group was 170.9 ± 24.1 compared to 170.3 ± 22.5 in the CS group (p = 0.3). Both groups had similar radiographic outcomes as determined by coronal and sagittal alignment, tibial slope and posterior condylar offset ratio measurements. When considering the size of tibial slope change and posterior-condylar offset ratio, there was no differences between groups (p = 0.4 and 0.59 respectively). The PS group had more interventions for post-operative stiffness (arthrolysis or manipulation under anaesthesia) 8 (2.7%) compared to 1 (0.6%) in the CS group (p = 0.17). Conclusion Condylar-stabilised TKA have similar patient outcomes and ROM at a mean follow-up of 3 years compared to PS TKA. Highly congruent inserts could be used without compromising results in TKA at short term. Level of evidence Level IV, retrospective case control study.
Collapse
Affiliation(s)
- Jobe Shatrov
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France.,Sydney Orthopaedic Research Institute, Chatswood, Sydney, Australia.,University of Notre Dame Australia, Sydney, Australia.,Hornsby and Ku-Ring Hospital, Sydney, Australia
| | - Elliot Sappey-Marinier
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France. .,Univ Lyon, Claude Bernard Lyon 1 University, IFSTTAR, LBMC UMR_T9406, F69622, Lyon, France.
| | - Moussa Kafelov
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France
| | - Stanislas Gunst
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France
| | - Cécile Batailler
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France.,Univ Lyon, Claude Bernard Lyon 1 University, IFSTTAR, LBMC UMR_T9406, F69622, Lyon, France
| | - Elvire Servien
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France.,LIBM - EA 7424, Interuniversity Laboratory of Biology of Mobility, Claude Bernard Lyon 1 University, Lyon, France
| | - Sébastien Lustig
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France.,Univ Lyon, Claude Bernard Lyon 1 University, IFSTTAR, LBMC UMR_T9406, F69622, Lyon, France
| |
Collapse
|
5
|
Sappey-Marinier E, Swan J, Maucort-Boulch D, Batailler C, Malatray M, Neyret P, Lustig S, Servien E. No significant clinical and radiological differences between fixed versus mobile bearing total knee replacement using the same semi-constrained implant type: a randomized controlled trial with mean 10 years follow-up. Knee Surg Sports Traumatol Arthrosc 2022; 30:603-611. [PMID: 33151364 DOI: 10.1007/s00167-020-06346-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/02/2020] [Accepted: 10/21/2020] [Indexed: 12/24/2022]
Abstract
PURPOSE The aim of this study was to compare the long-term clinical and radiological results between fixed (FB) and mobile bearing (MB) implants with identical design from the same manufacturer. METHODS From March 2007 to May 2009, we recruited 160 patients in a prospective, single centered, randomized controlled trial. The authors compared 81 FB total knee arthroplasty (TKA) versus 79 MB with medial compartment osteoarthritis. The same posterior stabilized HLS Noetos knee prosthesis (CORIN) was used in all patients. The two groups only differed by the tibial insert (fixed or mobile). The authors compared the postoperative Knee Society Score (KSS), the passive clinical and active radiological knee flexion, the implant survivorship, the complications, and the presence of radiolucent lines. RESULTS At mean 10.5 years' follow-up (range 8-12.1 years) no significant differences were found in clinical scores (KSS (p = 0.54), pain score (p = 0.77), stair climbing (p = 0.44), passive maximum flexion (p = 0.5)) or for radiological analyses (maximum active radiological flexion (p = 0.06), presence of progressive radiolucent lines (5 (MB group) versus 6 (FB group); p = 0.75)) between groups. No significant difference was found in overall implant survivorship (82% (MB group) versus 78% (FB group) p = 0.58) or complication rate (p = 0.32) at the last follow-up. CONCLUSION No significant clinical and radiological differences were found between fixed and mobile bearing TKA using the same semi-constrained implant type with comparable overall survivorship. The choice between a fixed or mobile bearing implant should be based on surgeon preference and experience with the selected implant. LEVEL OF EVIDENCE Prospective randomized controlled trial, Level II.
Collapse
Affiliation(s)
- E Sappey-Marinier
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, 103 Grande rue de la Croix Rousse, 69004, Lyon, France.
| | - J Swan
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, 103 Grande rue de la Croix Rousse, 69004, Lyon, France
| | - D Maucort-Boulch
- Service de Biostatistique - Bioinformatique, Pôle Santé Publique, Hospices Civils de Lyon, 69003, Lyon, France
- Université de Lyon, 69000, Lyon, France
- Université Lyon 1, 69100, Villeurbanne, France
- CNRS, UMR5558, Laboratoire de Biométrie Et Biologie Évolutive, Équipe Biostatistique-Santé, 69100, Villeurbanne, France
| | - C Batailler
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, 103 Grande rue de la Croix Rousse, 69004, Lyon, France
| | - M Malatray
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, 103 Grande rue de la Croix Rousse, 69004, Lyon, France
| | - P Neyret
- Infirmerie Protestante Lyon Caluire, 3 chemin du Penthod, 69300, Caluire et cuire, France
| | - S Lustig
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, 103 Grande rue de la Croix Rousse, 69004, Lyon, France
- Univ Lyon, Claude Bernard Lyon 1 University, IFSTTAR, LBMC UMR_T9406, 69622, Lyon, France
| | - E Servien
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, 103 Grande rue de la Croix Rousse, 69004, Lyon, France
- LIBM - EA 7424, Interuniversity Laboratory of Biology of Mobility, Claude Bernard Lyon 1 University, Lyon, France
| |
Collapse
|
6
|
Chen P, Huang L, Zhang D, Zhang X, Ma Y, Wang Q. Mobile Bearing versus Fixed Bearing for Total Knee Arthroplasty: Meta-analysis of Randomized Controlled Trials at Minimum 10-Year Follow-up. J Knee Surg 2022; 35:135-144. [PMID: 32590865 DOI: 10.1055/s-0040-1713356] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
This meta-analysis aimed to compare the clinical and radiographic outcomes between mobile-bearing total knee arthroplasty (MB-TKA) and fixed-bearing total knee arthroplasty (FB-TKA) at a minimum 10-year follow-up. PubMed, EMBASE, and Cochrane databases were searched. All included articles were evaluated by two trained reviewers according to the guidelines of the Cochrane Collaboration Handbook for potential risk, and the Consolidated Standards on Reporting Trials (CONSORT) checklist and scoring system was also used to assess the methodological quality of each study. The extracted data included function scores, range of motion (ROM) of the knee, incidence of adverse events or revision, survivorship analysis, and radiographic outcomes. Seven randomized controlled trials (RCTs) were included in this meta-analysis, and all RCTs had a follow-up period longer than 10 years. This meta-analysis shows no significant difference between the two groups with respect to the Keen Society Score (KSS; p = 0.38), KSS function score (p = 0.30), the Western Ontario and McMaster Universities Osteoarthritis index (WOMAC; p = 0.59), ROM (p = 0.71), radiolucent line (p = 0.45), femoral and tibial component positions in the coronal plane (p = 0.55 and 0.35, respectively), revision incidence (p = 0.77), and survivorship rates (p = 0.39). Meanwhile, it showed a slight difference between the two groups in the tibial component position in the sagittal plane (p = 0.003). According to this meta-analysis, the current best available evidence suggests no significant difference between the MB-TKA and FB-TKA groups with respect to the clinical outcomes, radiographic outcomes, revision, and survivorship at a minimum 10-year follow-up. This is a Level II, meta-analysis study.
Collapse
Affiliation(s)
- Pu Chen
- Department of Orthopaedic Surgery, Beijing University of Chinese Medicine Third Affiliated Hospital, Beijing, People's Republic of China
| | - Liuwei Huang
- Department of Nephrology, NanFang Hospital, Sourthern Medical University, Guangzhou, Guangdong Province, People's Republic of China
| | - Dong Zhang
- Department of Orthopaedic Surgery, Beijing University of Chinese Medicine Third Affiliated Hospital, Beijing, People's Republic of China
| | - Xiaozhe Zhang
- Department of Orthopaedic Surgery, Beijing University of Chinese Medicine Third Affiliated Hospital, Beijing, People's Republic of China
| | - Yufeng Ma
- Department of Orthopaedic Surgery, Beijing University of Chinese Medicine Third Affiliated Hospital, Beijing, People's Republic of China
| | - Qingfu Wang
- Department of Orthopaedic Surgery, Beijing University of Chinese Medicine Third Affiliated Hospital, Beijing, People's Republic of China
| |
Collapse
|
7
|
No difference between mobile and fixed bearing in primary total knee arthroplasty: a meta-analysis. Knee Surg Sports Traumatol Arthrosc 2022; 30:3138-3154. [PMID: 35861866 PMCID: PMC9418337 DOI: 10.1007/s00167-022-07065-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/10/2022] [Accepted: 07/01/2022] [Indexed: 11/09/2022]
Abstract
PURPOSE Both mobile (MB) and fixed (FB) bearing implants are routinely used for total knee arthroplasty (TKA). This meta-analysis compared MB versus FB for TKA in terms of implant positioning, joint function, patient reported outcome measures (PROMs), and complications. It was hypothesised that MB performs better than FB implants in primary TKA. METHODS This meta-analysis was conducted according to the 2020 PRISMA statement. In February 2022, the following databases were accessed: Pubmed, Web of Science, Google Scholar, Embase. All the randomized clinical trials (RCTs) comparing mobile versus fixed bearing for primary TKA were considered. RESULTS Data from 74 RCTs (11,116 procedures) were retrieved. The mean follow-up was 58.8 (7.5 to 315.6) months. The MB group demonstrated greater range of motion (ROM) (P = 0.02), Knee Society Score (KSS) score (P < 0.0001), and rate of deep infections (P = 0.02). No difference was found in implant positioning: tibial slope, delta angle, alpha femoral component angle, gamma femoral component angle, beta tibial component angle, tibiofemoral alignment angle, posterior condylar offset, radiolucent lines. No difference was found in duration of the surgical procedure. No difference was found in the following PROMs: Oxford Knee Score (OKS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), visual analogue scale (VAS), function and pain subscales of the KSS score. No difference was found in the rate of anterior knee pain, revision, aseptic loosening, fractures, and deep vein thrombosis. CONCLUSION There is no evidence in support that MB implants promote greater outcomes compared to FB implants in primary TKA. LEVEL OF EVIDENCE Level I.
Collapse
|
8
|
Wang K, Zhang FF, Yan X, Shen Y, Cai W, Xu J, Mei J. Superior Mid- to Long-Term Clinical Outcomes of Mobile-Bearing Total Knee Arthroplasty Compared to Fixed-Bearing: A Meta-Analysis Based on a Minimum of 5 Years of Study. J Knee Surg 2021; 34:1368-1378. [PMID: 32503063 DOI: 10.1055/s-0040-1709490] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
As more patients undergo total knee arthroplasty (TKA) each year, and the average age of patients gets younger, the patients are generally more active requiring a greater physiological demand and increasing range of motion on the prosthesis than the previous patients. However, there is no consensus on the optimal TKA tibial bearing design. We performed this systematic review to compare the clinical differences between mobile and fixed bearing constructs used in contemporary TKA. We searched PubMed, EMBASE, and Cochrane Library databases, identifying 515 total publications, including 17 randomized controlled trials (RCTs). A meta-analysis was performed, while the quality and bias of the evidence were rated according to the Grading of Recommendations Assessment Development and Evaluation (GRADE) guidelines and the Cochrane Database questionnaire. The meta-analysis was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines. Seventeen studies were included, with a total of 1505 knees receiving a mobile bearing TKA and 1550 knees receiving a fixed bearing TKA. The meta-analysis compared clinical outcomes between mobile bearing (MB)-TKA and fixed bearing (FB)-TKA using postoperative Knee Society Score, postoperative ROM, and survivorship and showed that there was a distinct difference in Knee Society Score between the mobile-bearing and fixed-bearing groups (overall standardized mean difference = 1.38; 95% confidence interval (CI): 0.50-2.25; p = 0.002; I2 = 60%). Patients treated with mobile-bearing prostheses were more likely to report good or excellent range of motion results (overall standardized mean difference = 2.06; 95% CI: 0.65-3.47; p = 0.004). No difference in implant survivorship or reoperation rate were identified. The fixed-bearing and mobile-bearing TKA designs are both capable of producing excellent long-term results with excellent clinical outcomes if properly implanted; however, the mobile-bearing TKA have superiority in mid- to long-term clinical results. Trial registration number for PROSPERO was CRD42019126402.
Collapse
Affiliation(s)
- Kaiyang Wang
- Department of Orthopedic Surgery, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, China
| | - Fang Fang Zhang
- Department of Orthopedic Surgery, Tongji University School of Medicine, Tongji Hospital, Shanghai, China
| | - Xu Yan
- Department of Orthopedic Surgery, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, China
| | - Yifan Shen
- Department of Orthopedic Surgery, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, China
| | - Weijie Cai
- Department of Orthopedic Surgery, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, China
| | - Jiaming Xu
- Department of Orthopedic Surgery, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, China
| | - Jiong Mei
- Department of Orthopedic Surgery, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, China
| |
Collapse
|
9
|
Angerame MR, Eschen CL, Johnson RM, Jennings JM, Dennis DA. Ten-Year Follow-Up of High-Flexion Versus Conventional Total Knee Arthroplasty: A Matched-Control Study. J Arthroplasty 2021; 36:2795-2800. [PMID: 33810919 DOI: 10.1016/j.arth.2021.03.017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/17/2020] [Revised: 02/16/2021] [Accepted: 03/02/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND High-flexion total knee arthroplasty (HF-TKA) prostheses were designed with hopes of improving knee function. Studies have suggested increased failure with HF-TKAs. The purpose is to compare clinical results of HF-TKA versus conventional TKA (C-TKA) from the same implant system with long-term follow-up. METHODS This review of prostheses implanted between 2004 and 2007 matched 145 of 179 possible HF-TKAs with 145 of 1347 possible C-TKAs. Mean follow-up was 121.5 ± 20.3 months. We were unable to match 12 HF-TKAs. HF-TKAs with less than 8-year follow-up were excluded. The primary outcome was failure requiring revision. Secondary outcomes included range of motion (ROM), Knee Society Scores (KSS), and radiolucent lines. RESULTS In the matched cohort, there were 15 HF-TKA reoperations, 8 of which involved component revisions. There were 12 reoperations in the C-TKA cohort but no component revisions (P = .001). The analysis of the unmatched cohorts revealed a higher revision rate for HF-TKAs (P = .039) (HF-TKA: 10/179 vs C-TKA: 27/1347). At final follow-up, HF-TKAs exhibited more prosthesis radiolucent lines without evidence of loosening. Particularly, HF-TKAs demonstrated more femoral zone IV radiolucencies (38.7%) at final follow-up compared with C-TKAs (13.8%) (P < .001). There were no differences found between cohorts in ROM or KSS. CONCLUSION This study found an increased incidence of failure requiring revision with the HF-TKA in the matched and unmatched analyses. Higher incidences of radiolucent lines were found with HF-TKA. With no observed differences in ROM or KSS and a higher rate of failure with HF-TKA, there appears to be no advantage for use of the HF-TKA.
Collapse
Affiliation(s)
- Marc R Angerame
- Illinois Bone & Joint Research and Education Institute, Des Plaines, IL
| | - Catie L Eschen
- Colorado Joint Replacement, Porter Adventist Hospital, Denver, CO
| | | | - Jason M Jennings
- Colorado Joint Replacement, Porter Adventist Hospital, Denver, CO; Department of Mechanical and Materials Engineering, University of Denver, Denver, CO
| | - Douglas A Dennis
- Colorado Joint Replacement, Porter Adventist Hospital, Denver, CO; Department of Mechanical and Materials Engineering, University of Denver, Denver, CO; Department of Orthopaedics, University of Colorado School of Medicine, Denver, CO; Department of Biomedical Engineering, University of Tennessee, Knoxville, TN
| |
Collapse
|
10
|
Hantouly AT, Ahmed AF, Alzobi O, Toubasi A, Salameh M, Elmhiregh A, Hameed S, Ahmed GO, Alvand A, Al Dosari MAA. Mobile-bearing versus fixed-bearing total knee arthroplasty: a meta-analysis of randomized controlled trials. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2021; 32:481-495. [PMID: 34021791 PMCID: PMC8924090 DOI: 10.1007/s00590-021-02999-x] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/24/2021] [Accepted: 04/09/2021] [Indexed: 11/24/2022]
Abstract
Objective The purpose of this study was to perform a meta-analysis comparing mobile-bearing with fixed-bearing total knee arthroplasty (TKA) in terms of all-cause revision rates, aspetic loosening, knee functional scores, range of motion and radiographic lucent lines and osteolysis. Methods PubMed, Cochrane Library, Google Scholar and Web of Science were searched up to January 2020. Randomized controlled trials that compared primary mobile-bearing with fixed-bearing TKA, reporting at least one of the outcomes of interest, at a minimum follow-up of 12 months were included. All outcomes of interest were pooled at short-term (< 5 years), mid-term (5 to 9 years) and long-term (> = 10 years) follow-up intervals. Results A total of 70 eligible articles were included in the qualitative and statistical analyses. There was no difference between mobile-bearing or fixed-bearing TKA at short-term, mid-term and long-term follow-ups in all outcome measures including all-cause revision rate, aseptic loosening, oxford knee score, knee society score, Hospital for Special Surgery score, maximum knee flexion, radiographic lucent lines and radiographic osteolysis. Conclusion The current level of evidence demonstrated that both mobile-bearing and fixed-bearing designs achieved excellent outcomes, yet it does not prove the theoretical advantages of the mobile-bearing insert over its fixed-bearing counterpart. The use of either design could therefore be supported based on the outcomes assessed in this study. Level of Evidence: Level II, Therapeutic Supplementary information The online version contains supplementary material available at (10.1007/s00590-021-02999-x).
Collapse
Affiliation(s)
- Ashraf T Hantouly
- Department of Orthopaedic Surgery, Surgical Specialty Center, Hamad Medical Corporation, Doha, Qatar
| | - Abdulaziz F Ahmed
- Department of Orthopaedic Surgery, Surgical Specialty Center, Hamad Medical Corporation, Doha, Qatar.
| | - Osama Alzobi
- Department of Orthopaedic Surgery, Surgical Specialty Center, Hamad Medical Corporation, Doha, Qatar
| | - Ammar Toubasi
- Department of Orthopaedic Surgery, Surgical Specialty Center, Hamad Medical Corporation, Doha, Qatar
| | - Motasem Salameh
- Department of Orthopaedic Surgery, Surgical Specialty Center, Hamad Medical Corporation, Doha, Qatar
| | - Aissam Elmhiregh
- Department of Orthopaedic Surgery, Surgical Specialty Center, Hamad Medical Corporation, Doha, Qatar
| | - Shamsi Hameed
- Department of Orthopaedic Surgery, Surgical Specialty Center, Hamad Medical Corporation, Doha, Qatar
| | - Ghalib O Ahmed
- Department of Orthopaedic Surgery, Surgical Specialty Center, Hamad Medical Corporation, Doha, Qatar
| | - Abtin Alvand
- Nuffield Department of Orthopaedics, Rheumatology & Musculoskeletal Sciences, University of Oxford, Oxford, UK
| | | |
Collapse
|
11
|
Long-Term (Up to 27 Years) Prospective, Randomized Study of Mobile-Bearing and Fixed-Bearing Total Knee Arthroplasties in Patients <60 Years of Age With Osteoarthritis. J Arthroplasty 2021; 36:1330-1335. [PMID: 33223412 DOI: 10.1016/j.arth.2020.10.050] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/18/2020] [Revised: 10/19/2020] [Accepted: 10/27/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Our study determined long-term (up to 27 years) results of fixed-bearing vs mobile-bearing total knee arthroplasties (TKAs) in patients <60 years with osteoarthritis. METHODS This study included 291 patients (582 knees; mean age 58 ± 5 years), who received a mobile-bearing TKA in one knee and a fixed-bearing TKA in the other. The mean duration of follow-up was 26.3 y (range 24-27). RESULTS At the latest follow-up, the mean Knee Society knee scores (91 ± 9 vs 89 ± 11 points, P = .383), Western Ontario and McMaster Universities Osteoarthritis Index (35 ± 7 vs 37 ± 6 points, P = .165), range of knee motion (128° ± 13° vs 125° ± 15°, P = .898), and University of California, Los Angeles activity score (6 ± 4 vs 6 ± 4 points, P = 1.000) were below the level of clinical significance between the 2 groups. Revision of mobile-bearing and fixed-bearing TKA occurred in 16 (5.5%) and 20 knees (6.9%), respectively. The rate of survival at 27 years for mobile-bearing and fixed-bearing TKA was 94.5% (95% confidence interval 89-100) and 93.1% (95% confidence interval 88-98), respectively, and no significant differences were observed between the groups. Osteolysis was identified in 4 knees (1.4%) in each group. CONCLUSION There were no significant differences in functional outcomes, rate of loosening, osteolysis, or survivorship between the 2 groups.
Collapse
|
12
|
Toyoda S, Kaneko T, Mochizuki Y, Hada M, Takada K, Ikegami H, Musha Y. Minimally invasive surgery total knee arthroplasty is less popular, but the prosthesis designed specifically for MIS provides good survival and PROMs with a minimum follow-up of 10 years. J Orthop Surg Res 2021; 16:95. [PMID: 33514399 PMCID: PMC7844949 DOI: 10.1186/s13018-021-02254-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2020] [Accepted: 01/20/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The concept of minimally invasive surgery (MIS) was introduced in total knee arthroplasty (TKA) in the late 1990s. The number of MIS TKAs has clearly decreased in recent years. An implant designed specifically for MIS TKA has been used all over the world, but there are no reports of long-term postoperative results. The purpose of this study was to characterize long-term clinical results with a minimum follow-up of 10 years. METHODS This retrospective study included 109 consecutive patients with 143 NexGen CR-Flex prostheses, which are MIS tibial component prostheses designed specifically for MIS TKA. Twelve-year survival analysis was performed using Kaplan-Meier method. Revision surgery for any reason was the endpoint. Long-term clinical and radiographic results of 74 knees (55%) in 60 patients with more than 10 years of follow-up were analyzed. RESULTS The cumulative survival rate of the single-radius posterior-stabilized TKA of 74 knees was 94.7% (95% confidence interval, 90-99%) at 12 years after surgery. Seven knees (9%) required additional surgery during the 10-year follow-up because of periprosthetic infections. Mean postoperative Knee Society knee score and functional score were 91 and 74 points, respectively. There were no cases of prosthesis breakage, polyethylene wear, or aseptic loosening of the prosthesis. CONCLUSION The prosthesis designed specifically for MIS TKA is associated with good survival and clinical results with a minimum follow-up of 10 years, even though MIS TKA has become less popular. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- Shinya Toyoda
- Department of Orthopedic Surgery, Toho University School of Medicine, 2-22-36 Ohashi, Meguro-ku, Tokyo, 153-8515, Japan
| | - Takao Kaneko
- Department of Orthopedic Surgery, Toho University School of Medicine, 2-22-36 Ohashi, Meguro-ku, Tokyo, 153-8515, Japan.
| | - Yuta Mochizuki
- Department of Orthopedic Surgery, Toho University School of Medicine, 2-22-36 Ohashi, Meguro-ku, Tokyo, 153-8515, Japan
| | - Masaru Hada
- Department of Orthopedic Surgery, Toho University School of Medicine, 2-22-36 Ohashi, Meguro-ku, Tokyo, 153-8515, Japan
| | - Kazutaka Takada
- Department of Orthopedic Surgery, Toho University School of Medicine, 2-22-36 Ohashi, Meguro-ku, Tokyo, 153-8515, Japan
| | - Hiroyasu Ikegami
- Department of Orthopedic Surgery, Toho University School of Medicine, 2-22-36 Ohashi, Meguro-ku, Tokyo, 153-8515, Japan
| | - Yoshiro Musha
- Department of Orthopedic Surgery, Toho University School of Medicine, 2-22-36 Ohashi, Meguro-ku, Tokyo, 153-8515, Japan
| |
Collapse
|
13
|
Lynch JT, Perriman DM, Scarvell JM, Pickering MR, Warmenhoven J, Galvin CR, Neeman T, Besier TF, Smith PN. Shape is only a weak predictor of deep knee flexion kinematics in healthy and osteoarthritic knees. J Orthop Res 2020; 38:2250-2261. [PMID: 32017242 DOI: 10.1002/jor.24622] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/04/2019] [Revised: 01/08/2020] [Accepted: 01/30/2020] [Indexed: 02/04/2023]
Abstract
Tibiofemoral shape influences knee kinematics but little is known about the effect of shape on deep knee flexion kinematics. The aim of this study was to examine the association between tibiofemoral joint shape and kinematics during deep kneeling in patients with and without osteoarthritis (OA). Sixty-one healthy participants and 58 patients with end-stage knee OA received a computed tomography (CT) of their knee. Participants completed full flexion kneeling while being imaged using single-plane fluoroscopy. Six-degree-of-freedom kinematics were measured by registering a three-dimensional (3D)-static CT onto 2D-dynamic fluoroscopic images. Statistical shape modeling and bivariate functional principal component analysis (bfPCA) were used to describe variability in knee shape and kinematics, respectively. Random-forest-regression models were created to test the ability of shape to predict kinematics controlling for body mass index, sex, and group. The first seven modes of the shape model up to three modes of the bfPCAs captured more than 90% of the variation. The ability of the random forest models to predict kinematics from shape was low, with no more than 50% of the variation being explained in any model. Furthermore, prediction errors were high, ranging between 24.2% and 29.4% of the data. Variations in the bony morphology of the tibiofemoral joint were weakly associated with the kinematics of deep knee flexion. The models only explained a small amount of variation in the data with high error rates indicating that additional predictors need to be identified. These results contribute to the clinical understanding of knee kinematics and potentially the expectations placed on high-flexion total knee replacement design.
Collapse
Affiliation(s)
- Joseph T Lynch
- Trauma and Orthopaedic Research Unit, The Australian National University, Canberra, Australian Capital Territory, Australia
| | - Diana M Perriman
- Trauma and Orthopaedic Research Unit, The Australian National University, Canberra, Australian Capital Territory, Australia
| | - Jennie M Scarvell
- Faculty of Health, University of Canberra, Canberra, Australian Capital Territory, Australia
| | - Mark R Pickering
- School of Engineering and Information Technology, University of New South Wales Canberra, Canberra, Australian Capital Territory, Australia
| | - John Warmenhoven
- Department of Exercise and Sports Science, The University of Sydney, Lidcombe, Australia.,Performance People & Teams, Australian Institute of Sport, Canberra, Australia
| | - Catherine R Galvin
- Faculty of Health, University of Canberra, Canberra, Australian Capital Territory, Australia
| | - Teresa Neeman
- Biological Data Science Institute, Australian National University, Canberra, Australian Capital Territory, Australia
| | - Thor F Besier
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Paul N Smith
- Trauma and Orthopaedic Research Unit, The Australian National University, Canberra, Australian Capital Territory, Australia
| |
Collapse
|
14
|
Sappey-Marinier E, de Abreu FGA, O'Loughlin P, Gaillard R, Neyret P, Lustig S, Servien E. No difference in patellar position between mobile-bearing and fixed-bearing total knee arthroplasty for medial osteoarthritis: a prospective randomized study. Knee Surg Sports Traumatol Arthrosc 2020; 28:1542-1550. [PMID: 31218390 DOI: 10.1007/s00167-019-05565-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/19/2019] [Accepted: 06/12/2019] [Indexed: 12/28/2022]
Abstract
PURPOSE Total knee arthroplasty (TKA) is the treatment of choice for severe osteoarthritis of the knee. Many studies have been performed comparing mobile- and fixed-bearing designs; however, there are insufficient data regarding the patellar position in either system. This study aimed to compare the resultant patellar position with a mobile- versus a fixed-bearing TKA and the influence of both designs on clinical outcomes. MATERIALS AND METHODS In this prospective randomized study, between 2007 and 2009, 160 TKA patients were assessed; 79 received a mobile-bearing and 81 received a fixed-bearing implant, for medial compartment osteoarthritis. A posteriorly stabilized, HLS Noetos knee prosthesis (Tornier, Saint-Ismier, France) was used in all cases. The only difference between the groups was whether the tibial component incorporated a fixed or mobile bearing. The patella was resurfaced in all cases. The International Knee Society Score (KSS) and the patellar tilt and translation were compared post-operatively. Patellar translation and patellar tilt analyses were subdivided into two subgroups (< 5 mm vs > 5 mm and < 5° vs > 5°). RESULTS The KSS was not statistically different between the groups at a mean follow-up of 7.4 years (range 5-11 years). Patellar translation and patellar tilt were not statistically different between the groups. When considering the patellar translation subgroup analysis, a significantly increased risk of patellar translation, greater than 5 mm, was found in the mobile-bearing group compared to fixed-bearing group (OR = 2.3; p = 0.048) without generating any meaningful difference in clinical outcomes. CONCLUSION The theoretical advantages of mobile-bearing implants compared to fixed-bearing implants were not demonstrated in this randomized study, at mid-term follow-up. In daily practice, the choice between mobile-bearing and fixed-bearing designs should be based on the experience and clinical judgment of the surgeon. LEVEL OF EVIDENCE Prospective randomized study, level I.
Collapse
Affiliation(s)
- Elliot Sappey-Marinier
- FIFA Medical Center of Excellence, Orthopaedics Surgery and Sports Medicine Department, Croix-Rousse Hospital, Hospices Civils de Lyon, 103 grande rue de la croix rousse, 69004, Lyon, France.
| | - Felipe Galvão A de Abreu
- FIFA Medical Center of Excellence, Orthopaedics Surgery and Sports Medicine Department, Croix-Rousse Hospital, Hospices Civils de Lyon, 103 grande rue de la croix rousse, 69004, Lyon, France
- Orthopaedic Department, Hospital Israelita Albert Einstein, Sao Paulo, SP, Brazil
| | - Padhraig O'Loughlin
- Department of Trauma and Orthopaedic Surgery, Cork University Hospital, Wilton, Cork, Ireland
| | - Romain Gaillard
- FIFA Medical Center of Excellence, Orthopaedics Surgery and Sports Medicine Department, Croix-Rousse Hospital, Hospices Civils de Lyon, 103 grande rue de la croix rousse, 69004, Lyon, France
| | - Philippe Neyret
- Clinique Genolier, 3 route du muids, 1272, Genolier, Switzerland
| | - Sebastien Lustig
- FIFA Medical Center of Excellence, Orthopaedics Surgery and Sports Medicine Department, Croix-Rousse Hospital, Hospices Civils de Lyon, 103 grande rue de la croix rousse, 69004, Lyon, France
- Univ Lyon, Claude Bernard Lyon 1 University, IFSTTAR, LBMC UMR_T9406, 69622, Lyon, France
| | - Elvire Servien
- FIFA Medical Center of Excellence, Orthopaedics Surgery and Sports Medicine Department, Croix-Rousse Hospital, Hospices Civils de Lyon, 103 grande rue de la croix rousse, 69004, Lyon, France
- LIBM - EA 7424, Interuniversity Laboratory of Biology of Mobility, Claude Bernard Lyon 1 University, Lyon, France
| |
Collapse
|
15
|
Park CH, Kang SG, Bae DK, Song SJ. Mid-term clinical and radiological results do not differ between fixed- and mobile-bearing total knee arthroplasty using titanium-nitride-coated posterior-stabilized prostheses: a prospective randomized controlled trial. Knee Surg Sports Traumatol Arthrosc 2019; 27:1165-1173. [PMID: 30088030 DOI: 10.1007/s00167-018-5095-z] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/18/2018] [Accepted: 08/03/2018] [Indexed: 01/31/2023]
Abstract
PURPOSE This study was performed to prospectively compare the clinical and radiographic results between mobile-bearing (MB) and fixed-bearing (FB) TKAs using ceramic titanium nitride (TiN)-coated prostheses. METHODS Seventy MB and 70 FB TKAs using TiN-coated prostheses (ACS®) were prospectively evaluated. There were no differences in demographic characteristics between the two groups. Clinically, the Knee Society knee and function scores, WOMAC, and range of motion (ROM) were compared. Considering the possibility of a kinematic change in the polyethylene (PE) insert and a decrease in ROM following MB TKA, serial changes in the ROM were also compared. The thickness of the PE insert was compared according to the size of the femoral component. Radiographically, the alignment and positions of the components were compared. RESULTS There were no differences between the two groups in clinical scores or ROM (n.s.). The maximum flexion increased from 133.5° ± 8.3° to 137.6° ± 5.5° across all time points in the MB group. The serial maximum flexion angles did not differ between the two groups over time (n.s.). The average thickness of the PE insert was greater in the MB group (12.0 ± 1.9 vs. 11.2 ± 1.6 mm, respectively, p = 0.008), especially when a large femoral component was used (12.7 ± 1.9 vs. 11.0 ± 1.5 mm, p = 0.005). The pre- and postoperative mechanical axes and positions of the components did not differ between the two groups (n.s.). CONCLUSIONS TiN-coated MB TKA showed no significant advantage over FB TKA. The selection of bearing design would be clinically insignificant when using the TiN-coated TKA prosthesis. LEVEL OF EVIDENCE II.
Collapse
Affiliation(s)
- Cheol Hee Park
- Department of Medicine, Graduate School, Kyung Hee University, 24 Kyunghee-daero, Dongdaemun-gu, Seoul, 02453, South Korea
| | - Se Gu Kang
- Department of Orthopaedic Surgery, College of Medicine, Kyung Hee University, 24 Kyunghee-daero, Dongdaemun-gu, Seoul, 02453, South Korea
| | - Dae Kyung Bae
- Department of Orthopaedic Surgery, College of Medicine, Kyung Hee University, 24 Kyunghee-daero, Dongdaemun-gu, Seoul, 02453, South Korea
| | - Sang Jun Song
- Department of Medicine, Graduate School, Kyung Hee University, 24 Kyunghee-daero, Dongdaemun-gu, Seoul, 02453, South Korea. .,Department of Orthopaedic Surgery, College of Medicine, Kyung Hee University, 24 Kyunghee-daero, Dongdaemun-gu, Seoul, 02453, South Korea.
| |
Collapse
|