1
|
Bunyoz KI, Tsikandylakis G, Mortensen K, Gromov K, Mohaddes M, Malchau H, Troelsen A. The size of the femoral head does not influence metal ion levels after metal-on-polyethylene total hip arthroplasty: a five-year report from a randomized controlled trial. Bone Joint J 2024; 106-B:31-37. [PMID: 38423094 DOI: 10.1302/0301-620x.106b3.bjj-2023-0795.r2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/02/2024]
Abstract
Aims In metal-on-polyethylene (MoP) total hip arthroplasty (THA), large metal femoral heads have been used to increase stability and reduce the risk of dislocation. The increased size of the femoral head can, however, lead to increased taper corrosion, with the release of metal ions and adverse reactions. The aim of this study was to investigate the relationship between the size of the femoral head and the levels of metal ions in the blood in these patients. Methods A total of 96 patients were enrolled at two centres and randomized to undergo MoP THA using either a 32 mm metal head or a femoral head of between 36 mm and 44 mm in size, being the largest possible to fit the thinnest available polyethylene insert. The levels of metal ions and patient-reported outcome measures (Oxford Hip Score, University of California, Los Angeles Activity Scale) were recorded at two and five years postoperatively. Results At five years, the median levels of chromium, cobalt, and titanium were 0.5 μg/l (interquartile range (IQR) 0.50 to 0.62), 0.24 μg/l (IQR 0.18 to 0.30), and 1.16 μg/l (IQR 1.0 to 1.68) for the 32 mm group, and 0.5 μg/l (IQR 0.5 to 0.54), 0.23 μg/l (IQR 0.17 to 0.39), and 1.30 μg/l (IQR 1 to 2.05) for the 36 mm to 44 mm group, with no significant difference between the groups (p = 0.825, p = 1.000, p = 0.558). There were increased levels of metal ions at two years postoperatively in seven patients in the 32 mm group, compared with four in the 36 mm to 44 mm group, and at five years postoperatively in six patients in the 32 mm group, compared with seven in the 36 mm to 44 mm group. There was no significant difference in either the OHS (p = 0.665) or UCLA (p = 0.831) scores between patients with or without an increased level of metal ions. Conclusion In patients who underwent MoP THA, we found no differences in the levels of metal ions five years postoperatively between those with a femoral head of 32 mm and those with a femoral head of between 36 mm and 44 mm, and no corrosion-related revisions. As taper corrosion can start after five years, there remains a need for longer-term studies investigating the relationship between the size of the femoral head size and corrosion in patients undergoing MoP THA.
Collapse
Affiliation(s)
- Kristine I Bunyoz
- Department of Orthopaedic Surgery, Copenhagen University Hospital, Hvidovre, Denmark
| | - Georgios Tsikandylakis
- Department of Orthopaedics, Sahlgrenska University Hospital, Gothenburg, Sweden
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Kristian Mortensen
- Department of Orthopaedic Surgery, Copenhagen University Hospital, Hvidovre, Denmark
| | - Kirill Gromov
- Department of Orthopaedic Surgery, Copenhagen University Hospital, Hvidovre, Denmark
| | - Maziar Mohaddes
- Department of Orthopaedics, Sahlgrenska University Hospital, Gothenburg, Sweden
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Henrik Malchau
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
- Harris Orthopaedic Laboratory, Department of Orthopaedics, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Anders Troelsen
- Department of Orthopaedic Surgery, Copenhagen University Hospital, Hvidovre, Denmark
| |
Collapse
|
2
|
Tower SS, Gessner BD, Cho CS, Bridges RL. The association of cobalturia with cobaltism symptoms a prospective blinded study of 229 post-arthroplasty patients. PLoS One 2023; 18:e0295203. [PMID: 38127904 PMCID: PMC10734948 DOI: 10.1371/journal.pone.0295203] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Accepted: 11/15/2023] [Indexed: 12/23/2023] Open
Abstract
INTRODUCTION Cobalt is a mitochondrial toxin, clinical cobaltism manifests with constitutional, neurologic, and cardiovascular symptomatology. Cobalt's severe toxidrome is known through case reports from extreme wear or corrosion of cobalt-chromium arthroplasty components. However, the spectrum and epidemiology of orthopedic-implant cobaltism and its relationship to duration and degree of cobalt exposure are not well defined. METHODS The relationship of urine-cobalt concentration and duration of exposure to cobalt-chromium joint implants and cobaltism symptomatology were prospectively studied in 229 patients. Subjects received a Cobaltism-Symptom-Inventory-Score (CSIS) based on a protocolized interview and examination followed by a spot urine-cobalt measurement. RESULTS 129 (56%) subjects were cobalturic (urine-cobalt ≥1.0 ppb). 122 (53%) subjects had a CSIS of >2, this status significantly associates with cobalturia. Median [IQR] urine-cobalt in the subjects with a CSIS >2 was 4.1[1.1-17.0] ppb compared to 0.5[0.5-1.4] ppb in subjects with CSIS ≤ 2. Cobalturia has a sensitivity of 0.69, a specificity of 0.77, and a positive predictive value of 0.74 for a CSIS of >2. The product of years-exposed to a cobalt-chromium implant and urine-cobalt by quartiles significantly positively associates with the Cobaltism-Symptom-Inventory-Score. CONCLUSION A urine-cobalt of ≥1 ppb likely indicates adverse systemic exposure to orthopedic-implant generated cobalt. Cobaltism severity as quantified by the CSIS significantly correlates with the product of spot urine-cobalt concentration and years-exposed to a cobalt-chromium orthopedic-implant indicating a dose-response relationship. Medical provider and public awareness of orthopedic-implant cobaltism is vital because tens-of-millions are at-risk and early cobaltism is reversible. Further use of cobalt-chromium orthopedic-implants should be questioned given cobaltism becomes clinically apparent at a spot urine-cobalt of 1 ppb or greater. Monitoring of patients with high-risk cobalt-chromium orthopedic-implants appears to be indicated.
Collapse
Affiliation(s)
- Stephen S. Tower
- University of Alaska, Medical School, Anchorage, Alaska, United States of America
| | | | - Christina S. Cho
- University of Alaska, Medical School, Anchorage, Alaska, United States of America
| | - Robert L. Bridges
- Aegis Imaging Consultants, Girdwood, Alaska, United States of America
| |
Collapse
|
3
|
Do cobalt and chromium blood metal ion levels normalize after revision of failed metal-on-metal total hip replacements? Arch Orthop Trauma Surg 2023; 143:1217-1221. [PMID: 34724103 DOI: 10.1007/s00402-021-04206-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/23/2021] [Accepted: 09/29/2021] [Indexed: 10/20/2022]
Abstract
INTRODUCTION Increased cobalt (Co) and chromium (Cr) serum levels are one reason for revision surgery in metal on metal (MoM) total hip arthroplasty (THA) patients. Dual mobility liners are a simple revision option; however, they preserve the metal shell and stem and it is therefore not clear if metal ion levels will fully normalize after revision surgery. MATERIAL AND METHODS Between April 2013 and December 2017 25 hips (24 patients) underwent revision from a MoM THA to an off-label dual mobility liner. Five patients were lost to follow-up and one patient refused leaving 18 patients (11 men, 7 female, average age 63.9 years) for pre- and postoperative metal ion level blood tests at a minimum follow-up of 2 years. RESULTS Fourteen patients were revised for osteolysis, two for elevated metal ion levels and two for fluid or cysts around the femoral or acetabular component. The average preoperative Co and Cr levels were 8.3 µg/l and 5.0 µg/l, respectively. At a minimum follow-up of 2 years (30-95 months), metal ions dropped to 0.8 µg/l. Harris Hip Score (HHS), Hip Osteoarthritis Outcome Score (HOOS), Visual Analog Scale (VAS) and the UCLA activity score improved non-significantly from pre- to postoperative. There was one postoperative complication in the study cohort. One patient with persisting pain required revision surgery to a standard acetabular component during the follow-up period. CONCLUSION The off-label use of a dual-mobility liner in the current study resulted in normalization of the metal ion levels suggesting that preserving the cobalt-chromium acetabular component has little impact on ion levels. In addition, dual mobility liners have a low complication and revision rate.
Collapse
|
4
|
Bunyoz KI, Tsikandylakis G, Mortensen K, Gromov K, Mohaddes M, Malchau H, Troelsen A. No difference in whole-blood metal ions between 32-mm and 36- to 44-mm femoral heads in metal-on-polyethylene total hip arthroplasty: a 2-year report from a randomised control trial. Hip Int 2023; 33:184-192. [PMID: 34102902 DOI: 10.1177/11207000211022623] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
AIM To investigate the effect of femoral head size on blood metal-ion levels caused by taper corrosion in metal-on-polyethylene total hip arthroplasty, comparing 36- to 44-mm heads with 32-mm heads. METHODS In a randomised, controlled, single-blinded trial, 96 patients were allocated to receive either a 32-mm metal head or the largest possible metal head (36-44 mm) that could be accommodated in the thinnest available vitamin E, cross-linked polyethylene insert. Blood metal ion levels were collected at 1- and 2-year follow-ups. RESULTS At 1-year, metal-ion levels did not differ between the groups. The median (interquartile range) blood-ion levels for the 32-mm versus the 36- to 44-mm group were 0.11 µg/L (0.08-0.15) versus 0.12 µg/L (0.08-0.22), p = 0.546, for cobalt, 0.50 µg/L (0.50-0.59) versus 0.50 µg/L (0.50-1.20), p = 0.059, for chromium and 1.58 µg/L (1.38-2.05) versus 1.48 µg/L (1.14-1.87), p = 0.385, for titanium. At 2 years, there was no difference either and the corresponding values were 0.15 µg/L (0.12-0.24) versus 0.18 µg/L (0.12-0.28), p = 0.682 for cobalt, 0.50 µg/L (0.50-0.50) versus 0.50 µg/L (0.50-0.57), p = 0.554, for chromium and 1.54 µg/L (1.16-1.87) versus 1.42 µg/L (1.01-1.72), p = 0.207 for titanium. CONCLUSIONS The use of the largest possible metal head (36-44 mm) compared to a 32-mm head in metal-on-polyethylene bearings does not appear to elevate blood metal-ion levels up to 2 years postoperatively. As taper corrosion is probably time-dependent, longer-term reports are needed to evaluate the association between large metal heads and blood metal ion levels.Trial registration: ClinicalTrials.gov (reg. ID NCT0231 6704).
Collapse
Affiliation(s)
- Kristine I Bunyoz
- Department of Orthopaedic Surgery, Copenhagen University Hospital, Hvidovre, Denmark
| | - Georgios Tsikandylakis
- Department of Orthopaedics, Sahlgrenska University Hospital, Gothenburg, Sweden.,Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Sweden
| | - Kristian Mortensen
- Department of Orthopaedic Surgery, Copenhagen University Hospital, Hvidovre, Denmark
| | - Kirill Gromov
- Department of Orthopaedic Surgery, Copenhagen University Hospital, Hvidovre, Denmark
| | - Maziar Mohaddes
- Department of Orthopaedics, Sahlgrenska University Hospital, Gothenburg, Sweden.,Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Sweden
| | - Henrik Malchau
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Sweden.,Harris Orthopaedic Laboratory, Department of Orthopaedics, Massachusetts General Hospital, Boston, USA
| | - Anders Troelsen
- Department of Orthopaedic Surgery, Copenhagen University Hospital, Hvidovre, Denmark
| |
Collapse
|
5
|
Ishida T, Tateiwa T, Takahashi Y, Masaoka T, Shishido T, Yamamoto K. Do polyethylene wear particles affect the development of pseudotumor in total hip arthroplasty? A minimum 15-year follow-up. J Orthop Surg Res 2023; 18:147. [PMID: 36849999 PMCID: PMC9972701 DOI: 10.1186/s13018-023-03634-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Accepted: 02/22/2023] [Indexed: 03/01/2023] Open
Abstract
BACKGROUND Adverse local tissue reactions have been problematic as an implant-related complication in total hip arthroplasty (THA). Despite the absence of significant metal wear and corrosion, granulomatous pseudotumor has been reported to be caused by polyethylene wear. We performed a long-term follow-up study investigating the relationship between polyethylene wear and pseudotumor formation in THA. METHODS This study included 57 patients (64 hips) that underwent primary THA with metal-on-polyethylene or ceramic-on-polyethylene bearing over a minimum follow-up of 15 years. They were stratified into pseudotumor and non-pseudotumor groups and their linear wear rates of polyethylene liner and serum cobalt (Co) and chromium (Cr) ion levels were compared. Pseudotumor was diagnosed on metal artifact reduction sequence-MRI according to its composition and wall thickness using the Hauptfleisch classification. RESULTS The incidence of pseudotumor was 34% (22/64 hips) at the mean follow-up of 16.9 years. Metal ion levels did not differ between the pseudotumor and non-pseudotumor groups, and none of the patients exceeded the Co/Cr ratio of 2.0 μg/L. Moreover, the wear rate in the pseudotumor group was 1.8 times greater than in the non-pseudotumor group (0.14 vs. 0.08 mm/year, P < 0.001). According to an analysis of the receiver operating characteristic curves, the cutoff level of the wear rate to discriminate between pseudotumor and non-pseudotumor patients at 15 years was 0.11 mm/year (area under the curve = 91%; sensitivity = 95%; specificity = 78%; accuracy = 87%). CONCLUSIONS Our results might provide new insights into excessive polyethylene wear potentially leading to the future development of both pseudotumor and osteolysis. Further studies are needed to clarify the direct relationship between polyethylene wear and pseudotumor and the mutual effects of osteolysis and pseudotumor in particle reactions.
Collapse
Affiliation(s)
- Tsunehito Ishida
- Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-Ku, Tokyo, 160-0023, Japan.
| | - Toshiyuki Tateiwa
- grid.410793.80000 0001 0663 3325Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-Ku, Tokyo, 160-0023 Japan
| | - Yasuhito Takahashi
- Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-Ku, Tokyo, 160-0023, Japan. .,Department of Bone and Joint Biomaterial Research, Tokyo Medical University, Tokyo, Japan.
| | - Toshinori Masaoka
- grid.410793.80000 0001 0663 3325Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-Ku, Tokyo, 160-0023 Japan
| | - Takaaki Shishido
- grid.410793.80000 0001 0663 3325Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-Ku, Tokyo, 160-0023 Japan
| | - Kengo Yamamoto
- grid.410793.80000 0001 0663 3325Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-Ku, Tokyo, 160-0023 Japan
| |
Collapse
|
6
|
Kobayashi K, Kidera K, Shiraishi K, Okazaki N, Chiba K, Yonekura A, Osaki M. High risk of elevated metal concentrations with 9/10-mm stem trunnions and highly cross-linked polyethylene grafted with poly(2-methacryloyloxyethyl phosphorylcholine) in total hip arthroplasty. J Orthop Surg Res 2023; 18:24. [PMID: 36627685 PMCID: PMC9830807 DOI: 10.1186/s13018-023-03510-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/02/2022] [Accepted: 01/05/2023] [Indexed: 01/12/2023] Open
Abstract
BACKGROUND The risks of metal release due to fretting and corrosion at the head-neck junction and consequent adverse local tissue reaction (ALTR) have concerns in metal-on-polyethylene (MoP) total hip arthroplasty (THA). Although trunnions have become thinner in diameter to increase the range of motion, it has remained unclear whether this change affects metal release and ALTR in vivo. This study aimed to investigate serum metal concentrations and the prevalence of ALTR in MoP THA with a 9/10-mm stem trunnion. PATIENTS AND METHODS A consecutive series of 37 hips that underwent THA using MoP grafted with poly(2-methacryloyloxyethyl phosphorylcholine) (PMPC) with a 9/10-mm trunnion stem were retrospectively reviewed. Serum metal levels were assessed and compared with those in MoP THA with a 10/12-mm trunnion stem. ALTR was diagnosed with serum metal levels and cross-sectional images. The factors associated with serum metal levels were also assessed. RESULTS The median serum cobalt and chromium levels were 1.5 μg/L and 1.0 μg/L in the 9/10-mm group and 0.2 μg/L and 0.4 μg/L in the 10/12-mm group, respectively. ALTR was found in 5 hips of 3 patients. Revision surgery was performed in 4 hips, and all stem trunnions and femoral heads showed severe corrosion. Postoperative walking ability was associated with serum metal levels. CONCLUSION It was found that a 9/10-mm stem trunnion with MoP grafted with PMPC had high risks of metal release in primary THA. Careful follow-up and cross-sectional imaging are needed to detect ALTR for early revision.
Collapse
Affiliation(s)
- Kyosuke Kobayashi
- grid.411873.80000 0004 0616 1585Nagasaki University Hospital, 1-7-1 Sakamoto, Nagasaki City, Nagasaki 852-8501 Japan
| | - Kenichi Kidera
- grid.411873.80000 0004 0616 1585Nagasaki University Hospital, 1-7-1 Sakamoto, Nagasaki City, Nagasaki 852-8501 Japan
| | - Kazuteru Shiraishi
- grid.411873.80000 0004 0616 1585Nagasaki University Hospital, 1-7-1 Sakamoto, Nagasaki City, Nagasaki 852-8501 Japan
| | - Narihiro Okazaki
- grid.411873.80000 0004 0616 1585Nagasaki University Hospital, 1-7-1 Sakamoto, Nagasaki City, Nagasaki 852-8501 Japan
| | - Ko Chiba
- grid.411873.80000 0004 0616 1585Nagasaki University Hospital, 1-7-1 Sakamoto, Nagasaki City, Nagasaki 852-8501 Japan
| | - Akihiko Yonekura
- grid.411873.80000 0004 0616 1585Nagasaki University Hospital, 1-7-1 Sakamoto, Nagasaki City, Nagasaki 852-8501 Japan
| | - Makoto Osaki
- grid.411873.80000 0004 0616 1585Nagasaki University Hospital, 1-7-1 Sakamoto, Nagasaki City, Nagasaki 852-8501 Japan
| |
Collapse
|
7
|
Lachance AD, Stogsdill PB, McGrory BJ. Late Hematogenous Total Hip Infection After Revision for Mechanically Assisted Crevice Corrosion With Adverse Local Tissue Reaction. Arthroplast Today 2022; 18:173-180. [PMID: 36387330 PMCID: PMC9647085 DOI: 10.1016/j.artd.2022.10.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/12/2022] [Revised: 10/15/2022] [Accepted: 10/17/2022] [Indexed: 11/08/2022] Open
Abstract
Mechanically assisted crevice corrosion (MACC) at the trunnion-bore junction of a total hip arthroplasty may cause adverse local tissue reaction (ALTR) with inflammatory reaction and tissue necrosis. Complications, including acute infection, continued pain, and instability, are therefore common after a revision surgery for MACC. We now present 2 cases of late hematogenous bacterial infection years after revision for MACC and ALTR, a previously unreported outcome in this population. We hypothesize that MACC-induced tissue necrosis does not heal over time, and some patients with metal-on-polyethylene total hip arthroplasty treated for ALTR are at long-term risk of hematogenous bacterial infection.
Collapse
|
8
|
Metal Articulations as a Source of Total Hip Arthroplasty Pain. J Arthroplasty 2022; 37:1483-1487. [PMID: 35101592 DOI: 10.1016/j.arth.2022.01.063] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2021] [Revised: 01/03/2022] [Accepted: 01/20/2022] [Indexed: 02/02/2023] Open
Abstract
The consensus systematic risk stratification algorithm from the American Association of Hip and Knee Surgeons, the American Academy of Orthopaedic Surgeons, and The Hip Society summarizes clinical challenges in evaluation and treatment of metal-on-polyethylene total hip arthroplasty (THA) patients with adverse local tissue reaction (ALTR) due to mechanically assisted crevice corrosion (MACC), reviews up-to-date evidence, and identifies the areas for future research in order to provide a useful resource for orthopedic surgeons providing care to these patients. A painful THA has various intrinsic and extrinsic causes. ALTR is one of the intrinsic causes in patients with painful THA. The occurrence of ALTR due to MACC at modular junctions is likely to be multifactorial, including implant, surgical, and patient factors. Therefore, a systematic evaluation needs to involve a focused clinical history, detailed physical examination, laboratory tests, and imaging in order to identify potential differential diagnoses. There should be a low threshold to perform a systematic evaluation of patients with painful non-metal-on-metal THA, including patients with metal-on-polyethylene THA, and modular dual-mobility THA with the CoCr metal acetabular insert, as early recognition and diagnosis of ALTR due to MACC will facilitate initiation of appropriate treatment prior to significant adverse biological reactions. Specialized tests such as blood metal analysis and metal artifact reduction sequence magnetic resonance imaging are important modalities in evaluation and management of ALTR in patients with painful THA.
Collapse
|
9
|
McGrory BJ. High Incidence of Mechanically Assisted Crevice Corrosion at 10 Years in Non-Cemented, Non-Recalled, Contemporary Total Hip Arthroplasties. J Arthroplasty 2022; 37:S941-S946. [PMID: 34822931 DOI: 10.1016/j.arth.2021.11.026] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/16/2021] [Revised: 10/19/2021] [Accepted: 11/02/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND One percent to 3% of contemporary non-cemented total hip arthroplasties (THAs) present with symptomatic mechanically assisted crevice corrosion (MACC). The incidence of this problem, however, as well as the rate of asymptomatic elevations in serum cobalt, is unknown. METHODS Cobalt and chromium levels were obtained in conjunction with radiographs at routine 10-year surveillance follow-up of THAs from a single manufacturer with a titanium stem, cobalt alloy femoral head, and cross-linked polyethylene countersurface. RESULTS Ten-year follow-up of patients with 162 consecutive THAs revealed that 17 patients with 18 hips had died of unrelated causes prior to metal ion testing. Two hips were revised for other reasons, and of the remaining 142 hips, 33 were in patients who were lost, leaving 109 hips (77% of those in alive patients and unrevised for other reasons and 67% of the entire cohort) for investigation. Sixty-three patients (58%) had a serum cobalt less than 1 ppb, and 35 (32%) a cobalt of ≥1 ppb, a cutoff consistent with MACC. Of the 32 hips with definite MACC, 15 of 32 (47%) patients were symptomatic, 16 of 30 (53%) patients had adverse local tissue reaction on magnetic resonance imaging, and 19 of 32 (59%) patients have undergone revision surgery for MACC to date. CONCLUSION At 10-year follow-up, a minimum of 22% (35/162) of hips had a cobalt level more than 1 ppb, consistent with MACC. Symptoms and adverse local tissue reactions are each present about one-half of the time, and 59% of those with documented MACC have undergone revision.
Collapse
Affiliation(s)
- Brian J McGrory
- Tufts University School of Medicine, Maine Medical Center, Portland, Maine
| |
Collapse
|
10
|
Imaging in Hip Arthroplasty Management Part 2: Postoperative Diagnostic Imaging Strategy. J Clin Med 2022; 11:jcm11154416. [PMID: 35956033 PMCID: PMC9369831 DOI: 10.3390/jcm11154416] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2022] [Revised: 07/20/2022] [Accepted: 07/24/2022] [Indexed: 12/04/2022] Open
Abstract
Hip arthroplasty (HA) is a frequently used procedure with high success rates, but 7% to 27% of the patients complain of persistent postsurgical pain 1 to 4 years post-operation. HA complications depend on the post-operative delay, the type of material used, the patient’s characteristics, and the surgical approach. Radiographs are still the first imaging modality used for routine follow-up, in asymptomatic and painful cases. CT and MRI used to suffer from metallic artifacts but are nowadays central in HA complications diagnosis, both having their advantages and drawbacks. Additionally, there is no consensus on the optimal imaging workup for HA complication diagnosis, which may have an impact on patient management. After a brief reminder about the different types of prostheses, this article reviews their normal and pathologic appearance, according to each imaging modality, keeping in mind that few abnormalities might be present, not anyone requiring treatment, depending on the clinical scenario. A diagnostic imaging workup is also discussed, to aid the therapist in his imaging studies prescription and the radiologist in their practical aspects.
Collapse
|
11
|
Whiteside LA. Clinical Results of Revision TKA in Patients With Presumed Metal and Cement Allergy. J Arthroplasty 2022; 37:S250-S257. [PMID: 35196568 DOI: 10.1016/j.arth.2022.02.052] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Revised: 02/10/2022] [Accepted: 02/11/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Metal and cement allergy affects a small subset of patients, causing severe pain and often systemic reaction after total knee arthroplasty (TKA). Revision with ceramic-surfaced femoral components has been reported to resolve these symptoms of metal allergy, but no solution currently is available for patients with allergies to metal and bone cement. METHODS Five patients (5 knees) with documented metal allergy were revised with custom porous-coated ceramic femoral components (Magnesia-stabilized Zirconia) from January 2007 to January 2013. An additional 23 patients (23 knees) met inclusion criteria from 2007 to 2015, but because the ceramic implant was unavailable, they underwent different treatment based on their underlying allergy to metal, cement, or both. Inclusion criteria included the history of clinically documented severe metal allergy, severe pain, swelling, and effusion >1 year after TKA, negative workup for infection, loosening, and ligament imbalance. Knee Society scores were compared for each cohort. RESULTS Mean Knee Society scores for all 5 patients revised with custom cementless ceramic femoral components improved significantly for objective score (preoperative, 39 ± 5; most recent visit, 90 ± 2) and function score (preoperative, 33 ± 8; most recent visit 93 ± 4) (P < .0001). The 12 knees revised with off-the-shelf cemented ceramic-coated femoral components had similar results. The 7 unrevised knees (including 4 knees with allergy to metal and bone cement) and the 4 knees revised with standard CoCr femoral components did not improve and worsened over time. CONCLUSION Symptoms resolved in the 5 patients revised with custom ceramic implants and in the 12 patients revised with ceramic-coated components, but did not improve in the patients unrevised or revised with CoCr femoral components. Symptoms presumed to be associated with metal or cement allergy improve with the use of ceramic femoral surfaces, but patients who are allergic both to metals and bone cement would be candidates only for porous-coated ceramic implants fixed without bone cement.
Collapse
|
12
|
Snyder MJ, Weber MA, Kromka JJ, Sims MM, Smith CN, Daji AV, Kumar D, Borrero CG, Cordle AC, DiGioia AM, Hamlin BR, Plakseychuk AY, Urish KL. Predictors of Adverse Local Tissue Reaction in a High-Risk Population. Arthroplast Today 2022; 13:125-129. [PMID: 35106348 PMCID: PMC8784296 DOI: 10.1016/j.artd.2021.12.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Revised: 11/30/2021] [Accepted: 12/15/2021] [Indexed: 11/08/2022] Open
Abstract
Background Adverse local tissue reaction (ALTR) is a recognized complication of total hip arthroplasty (THA) with metal-on-polyethylene (MoP) bearing surface implants. Specific models of THA implants have been identified as having a higher incidence of ALTR. The purpose of this study is to determine if serum metal levels, patient symptoms, implant factors, and imaging findings can be predictive of ALTR within this high-risk population. Methods We retrospectively reviewed an observational cohort of 474 patients who underwent MoP THA and were at increased risk of having ALTR. Patients were stratified based on the presence or absence of ALTR. Patient symptoms, serum metal ions, implant head offset, and imaging findings were compared. Results Patients with ALTR were more likely to be symptomatic (52.9% vs 9.9%, P < .0001). The presence of ALTR was associated with significantly higher serum cobalt and chromium levels (6.2 ppb vs 3.6 ppb, P < .0001; 2.3 ppb vs 1.2 ppb, P < .0001). Head offsets greater than 4 mm were associated with a higher prevalence of ALTR (53% vs 38%, P = .05). On metal artifact reduction sequence magnetic resonance imaging, patients with ALTR had larger effusions (4.7 cm vs 2.1 cm, P < .001) and a higher incidence of trochanteric bursitis (47% vs 16%, P < .001). Conclusions In high-risk MoP implants, serum cobalt and chromium levels are elevated, even in patients without ALTR. A larger femoral head offset is a risk factor for the development of ALTR. Our study suggests that patients presenting with painful THA and elevated metal ions require risk stratification based on patient symptoms, metal artifact reduction sequence magnetic resonance imaging findings, and implant factors.
Collapse
|
13
|
Vechetti IJ, Wen Y, Hoffman JF, Alimov AP, Vergara VB, Kalinich JF, Gaitens JM, Hines SE, McDiarmid MA, McCarthy JJ, Peterson CA. Urine miRNAs as potential biomarkers for systemic reactions induced by exposure to embedded metal. Biomark Med 2021; 15:1397-1410. [PMID: 34541869 DOI: 10.2217/bmm-2021-0120] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
Aim: Explore the potential of urine microRNAs as biomarkers that may reflect the biological responses to pure metals embedded in skeletal muscle over time. Materials & methods: We tested a panel of military-relevant metals embedded in the gastrocnemius muscles of 3-month-old, male, Sprague-Dawley rats (n = 8/group) for a duration of 1, 3, 6 and 12 months, and performed small RNA-sequencing on the urine samples. Results: Results provide potential tissue targets affected by metal exposure and a list of unique or common urine microRNA biomarkers indicative of exposure to various metals, highlighting a complex systemic response. Conclusion: We have identified a panel of miRNAs as potential urine biomarkers to reflect the complex systemic response to embedded metal exposure.
Collapse
Affiliation(s)
- Ivan J Vechetti
- Department of Nutrition & Health Sciences, College of Education & Human Sciences, University of Nebraska-Lincoln, Lincoln, NE 68583, USA
| | - Yuan Wen
- Department of Physical Therapy, College of Health Sciences, University of Kentucky, Lexington, KY 40536, USA
- Center for Muscle Biology, University of Kentucky, Lexington, KY 40536, USA
| | - Jessica F Hoffman
- Internal Contamination & Metal Toxicity Program, Armed Forces Radiobiology Research Institute, Uniformed Services University, Bethesda, MD 20814, USA
| | - Alexander P Alimov
- Center for Muscle Biology, University of Kentucky, Lexington, KY 40536, USA
- Department of Physiology, College of Medicine, University of Kentucky, Lexington, KY 40536, USA
| | - Vernieda B Vergara
- Internal Contamination & Metal Toxicity Program, Armed Forces Radiobiology Research Institute, Uniformed Services University, Bethesda, MD 20814, USA
| | - John F Kalinich
- Internal Contamination & Metal Toxicity Program, Armed Forces Radiobiology Research Institute, Uniformed Services University, Bethesda, MD 20814, USA
| | - Joanna M Gaitens
- Department of Veterans Affairs Medical Center Baltimore, Baltimore, MD 21201, USA
- Department of Medicine, University of Maryland School of Medicine, Baltimore, MD 21201, USA
| | - Stella E Hines
- Department of Veterans Affairs Medical Center Baltimore, Baltimore, MD 21201, USA
- Department of Medicine, University of Maryland School of Medicine, Baltimore, MD 21201, USA
| | - Melissa A McDiarmid
- Department of Veterans Affairs Medical Center Baltimore, Baltimore, MD 21201, USA
- Department of Medicine, University of Maryland School of Medicine, Baltimore, MD 21201, USA
| | - John J McCarthy
- Center for Muscle Biology, University of Kentucky, Lexington, KY 40536, USA
- Department of Physiology, College of Medicine, University of Kentucky, Lexington, KY 40536, USA
| | - Charlotte A Peterson
- Department of Physical Therapy, College of Health Sciences, University of Kentucky, Lexington, KY 40536, USA
- Center for Muscle Biology, University of Kentucky, Lexington, KY 40536, USA
| |
Collapse
|
14
|
Houdek MT, Taunton MJ, Wyles CC, Jannetto PJ, Lewallen DG, Berry DJ. Synovial Fluid Metal Ion Levels are Superior to Blood Metal Ion Levels in Predicting an Adverse Local Tissue Reaction in Failed Total Hip Arthroplasty. J Arthroplasty 2021; 36:3312-3317.e1. [PMID: 34030874 PMCID: PMC9376798 DOI: 10.1016/j.arth.2021.04.034] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/24/2021] [Revised: 04/21/2021] [Accepted: 04/26/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Adverse local tissue reactions (ALTR) are associated with total hip arthroplasty (THA) failure in patients with metal-on-metal bearings and/or taper corrosion, which can also occur in metal-on-polyethylene articulations. Patients are monitored with blood cobalt (Co) and chromium (Cr) concentrations which do not always correlate with the degree of soft tissue reaction at revision THA. The purpose of this study was to determine how the blood and prosthetic hip synovial fluid levels of Co and Cr correlate with one another, and determine which concentration is more predictive of ALTR. METHODS Synovial fluid and blood samples were collected at the time of revision THA in patients with (n = 26) and without ALTR (n = 27). Whole blood, serum, and synovial fluid metal ion concentrations were correlated with one another and clinical findings. RESULTS The ratio of synovial fluid to whole blood Co concentration in ALTR and non-ALTR hips was 120:1 and 18:1 (P = .006). The mean ratio of synovial fluid to whole blood Cr concentration in ALTR and non-ALTR hips was 414:1 and 24:1 (P = .01). The mean synovial fluid Co/Cr concentrations were elevated in patients with ALTR compared with those without (2007.3 vs. 12.4 ppb, P = .007) and (3188.2 vs. 10.3 ppb, P = .02). The synovial fluid Co concentration was the most accurate test for detecting ALTR (cut off: 19.75 PPB, AUC 0.973). CONCLUSION In patients with ALTR, synovial fluid Co and Cr levels were 120 times higher and 414 times higher than whole blood Co and Cr levels. Synovial fluid Co ion concentration was the most accurate in predicting ALTR. LEVEL OF EVIDENCE Diagnostic level II.
Collapse
Affiliation(s)
- Matthew T. Houdek
- Mayo Clinic, Department of Orthopedic Surgery, 200 First St. SW, Rochester, MN 55905
| | - Michael J. Taunton
- Mayo Clinic, Department of Orthopedic Surgery, 200 First St. SW, Rochester, MN 55905
| | - Cody C. Wyles
- Mayo Clinic, Department of Orthopedic Surgery, 200 First St. SW, Rochester, MN 55905
| | - Paul J. Jannetto
- Mayo Clinic, Department of Laboratory Medicine and Pathology, 200 First St. SW, Rochester, MN 55905
| | - David G. Lewallen
- Mayo Clinic, Department of Orthopedic Surgery, 200 First St. SW, Rochester, MN 55905
| | - Daniel J. Berry
- Mayo Clinic, Department of Orthopedic Surgery, 200 First St. SW, Rochester, MN 55905,Corresponding Author: Correspondence: Daniel J. Berry, M.D., Mayo Clinic, Department of Orthopedic Surgery, 200 First St. SW, Rochester, MN 55905, Telephone Number: 507-284-8314,
| |
Collapse
|
15
|
Weber MA, Snyder MJ, Workman KK, Sims MM, Smith CN, Kumar D, Daji AV, Borrero CG, Cordle AC, DiGioia AM, Hamlin BR, Plakseychuk AY, Urish KL. Comparison of Asymptomatic and Symptomatic Adverse Local Tissue Reaction in Patients With Head-Neck Taper Corrosion. J Arthroplasty 2021; 36:S358-S362. [PMID: 33036841 PMCID: PMC7965776 DOI: 10.1016/j.arth.2020.09.014] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Revised: 08/29/2020] [Accepted: 09/11/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Diagnosis of adverse local tissue reaction (ALTR) in metal-on-polyethylene (MoP) total hip arthroplasty (THA) secondary to head-neck taper corrosion is challenging. The purpose of this study is to compare differences between asymptomatic and symptomatic ALTR in an observational cohort, including presentation, metal ion differences, and metal artifact reduction sequence (MARS) magnetic resonance imaging (MRI) findings. METHODS We performed a retrospective review of an observational cohort of 492 MoP THA patients at increased risk of developing ALTR. Ninety-four patients underwent revision arthroplasty for ALTR. Patients were stratified into symptomatic and asymptomatic ALTR groups. Presentation, metal ion levels, and imaging findings were compared. RESULTS For patients with confirmed ALTR, 41% were asymptomatic. There was a statistically significant difference in the serum chromium levels between symptomatic and asymptomatic ALTR patients (2.2 μg/L vs 3.1 μg/L, P = .05). There was no statistically significant difference between the serum cobalt levels or MRI findings in these 2 groups. We observed that extracapsular disease associated with ALTR could be misinterpreted as trochanteric bursitis. CONCLUSION Almost half of the MoP THA ALTR cases identified were asymptomatic. Cobalt levels could not differentiate between symptomatic and asymptomatic pseudotumor formation. Symptomatic and asymptomatic MoP ALTRs have similar MARS MRI characteristics. Our findings suggest that it is essential to risk stratify patients who could potentially have ALTR based on implant type, symptoms, ion levels, and MARS MRI.
Collapse
Affiliation(s)
| | | | - Kalain K Workman
- Department of Orthopedic Surgery, University of Pittsburgh Medical Center-Pinnacle, Harrisburg, PA
| | - Margaret M Sims
- The Bone & Joint Center, Magee Women's Hospital of the University of Pittsburgh Medical Center, Pittsburgh, PA
| | - Clair N Smith
- Department of Orthopedic Surgery, University of Pittsburgh School of Medicine, Pittsburgh, PA
| | - Deepak Kumar
- University of Pittsburgh School of Medicine, Pittsburgh, PA
| | - Akshay V Daji
- University of Pittsburgh School of Medicine, Pittsburgh, PA
| | - Camilo G Borrero
- Department of Radiology, University of Pittsburgh Medical Center, Pittsburgh, PA
| | - Andrew C Cordle
- Department of Radiology, University of Pittsburgh Medical Center, Pittsburgh, PA
| | - Anthony M DiGioia
- The Bone & Joint Center, Magee Women's Hospital of the University of Pittsburgh Medical Center, Pittsburgh, PA
| | - Brian R Hamlin
- The Bone & Joint Center, Magee Women's Hospital of the University of Pittsburgh Medical Center, Pittsburgh, PA
| | - Anton Y Plakseychuk
- The Bone & Joint Center, Magee Women's Hospital of the University of Pittsburgh Medical Center, Pittsburgh, PA
| | - Kenneth L Urish
- The Bone & Joint Center, Magee Women's Hospital of the University of Pittsburgh Medical Center, Pittsburgh, PA; Arthritis and Arthroplasty Design Lab, Department of Orthopaedic Surgery, University of Pittsburgh; Department of Bioengineering, and Clinical and Translational Science Institute, University of Pittsburgh, Pittsburgh, PA
| |
Collapse
|
16
|
French JMR, Bramley P, Scattergood S, Sandiford NA. Adverse reaction to metal debris due to fretting corrosion between the acetabular components of modular dual-mobility constructs in total hip replacement: a systematic review and meta-analysis. EFORT Open Rev 2021; 6:343-353. [PMID: 34150328 PMCID: PMC8183148 DOI: 10.1302/2058-5241.6.200146] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
Abstract
Modular dual-mobility (MDM) constructs can be used to reduce dislocation rates after total hip replacement (THR). However, there are concerns about adverse reaction to metal debris (ARMD) as a result of fretting corrosion between the metal liner and shell. This systematic review reports outcomes following THR using MDM components. It was registered with PROSPERO and conducted in line with Cochrane and PRISMA recommendations.Sixteen articles were included overall, with meta-analysis performed on relevant subsets using a random intercept logistic regression model. Estimated median incidence of ARMD requiring revision surgery within study follow-up period was 0.3% (95% CI 0.1 - 1.8%, from 11 cohort studies containing 1312 cases).Serum metal ion levels were mildly raised in 7.9% of cases, and significantly raised in 1.8%, but there was no correlation with worse clinical hip function scores within studies. Dislocation rate was 0.8%. Revision rate was 3.3%.There are mixed reports of wear on the backside of the metal liner from the acetabular shell and screw heads. Both implant design and component malseating are implicated, but currently it is unclear to what extent each factor is responsible.Studies were poor quality with high risk of confounding, especially from trunnion corrosion. We have made recommendations for further work. In the meantime, surgeons should be aware of the potential risk of ARMD when considering using an MDM prosthesis, and, if selecting one, must ensure proper seating of the liner and screws intraoperatively. Cite this article: EFORT Open Rev 2021;6:343-353. DOI: 10.1302/2058-5241.6.200146.
Collapse
Affiliation(s)
- Jonathan M R French
- Bristol Royal Infirmary, University Hospitals Bristol NHS Trust, Bristol, UK
| | - Paul Bramley
- Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, UK
| | - Sean Scattergood
- Bristol Royal Infirmary, University Hospitals Bristol NHS Trust, Bristol, UK
| | | |
Collapse
|
17
|
Radiographic Risk Factors Associated With Adverse Local Tissue Reaction in Head-Neck Taper Corrosion of Primary Metal-on-Polyethylene Total Hip Arthroplasty. J Am Acad Orthop Surg 2021; 29:353-360. [PMID: 32796372 DOI: 10.5435/jaaos-d-20-00473] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/01/2020] [Accepted: 07/05/2020] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Adverse local tissue reactions (ALTRs) in metal-on-polyethylene (MoP) total hip arthroplasty (THA) with head-neck taper corrosion are multifactorial, involving implant and patient factors. This study aimed to identify any potential clinical risk factors associated with failed MoP THA due to head-neck taper corrosion. METHODS A series of 146 MoP THA patients was investigated: (1) ALTR (n = 42) on metal artifact sequence MRI and (2) non-ALTR (n = 104). Both cohorts were compared regarding femoral neck shaft angle, acetabular implant orientation, component size, femoral head offset, measurement of medial and vertical femoral offsets, and femoral stem alloy. RESULTS The occurrence of ALTR was associated with increased radiographic femoral stem offset (36.0 ± 7.7 mm versus 40.8 ± 7.3 mm, P = 0.008), increased femoral head offset (0.7 ± 3.4 versus 4.5 ± 3.7, P < 0.001), and the use of Ti-12Mo-6Zr-2Fe alloy stems (P = 0.041). The presence of ALTR was notably associated with higher chromium (2.0 versus 0.5 μg/L) and cobalt (7.4 versus 0.7 μg/L, P < 0.001). DISCUSSION This study identified increased femoral head and stem offset and the use of Ti-12Mo-6Zr-2Fe alloy stems as risk factors for clinically relevant ALTR due to head-neck taper corrosion in MoP THA patients. This provides evidenced-based practical information for surgeons in identifying "at-risk" symptomatic MoP THA patients with head-neck taper corrosion for systematic risk stratification.
Collapse
|
18
|
Kwon YM, Della Valle CJ, Lombardi AV, Garbuz DS, Berry DJ, Jacobs JJ. Risk Stratification Algorithm for Management of Head-Neck Taper Tribocorrosion in Patients with Metal-on-Polyethylene Total Hip Arthroplasty: Consensus Statement of the American Association of Hip and Knee Surgeons, the American Academy of Orthopaedic Surgeons, and The Hip Society. J Bone Joint Surg Am 2021; 103:e18. [PMID: 33411461 DOI: 10.2106/jbjs.20.01837] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Adverse local tissue reactions (ALTRs) were initially reported as complications associated with metal-on-metal (MoM) bearings; however, there is increasing concern regarding the occurrence of adverse local tissue reactions from mechanically assisted crevice corrosion (MACC) at the femoral head-neck junction or between other modular junctions of the implant containing cobalt chromium parts in patients with metal-on-polyethylene (MoP) bearings. ALTR due to MACC at the head-neck junction has primarily been reported in association with cobalt chromium alloy femoral heads. As pain following total hip arthroplasty may have various intrinsic and extrinsic causes, a systematic approach to evaluation (risk stratification algorithm) based on the currently available data is recommended to optimize patient management. Evaluation should begin by ruling out common causes of pain, including component loosening and periprosthetic joint infection. While specialized tests such as blood metal analysis and metal artifact reduction sequence magnetic resonance imaging (MARS MRI) are useful modalities in evaluating for ALTRs, over-reliance on any single investigative tool in the clinical decision-making process should be avoided. There should be a low threshold to perform a systematic evaluation for ALTR due to MACC in patients with metal-on-polyethylene total hip arthroplasty as early recognition and diagnosis is critical, as delays in appropriate treatment initiation may result in soft-tissue damage, which complicates surgical treatment and is associated with a higher risk of complications and poorer patient outcomes.
Collapse
Affiliation(s)
- Young-Min Kwon
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts
| | - Craig J Della Valle
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois
| | - Adolph V Lombardi
- Joint Implant Surgeons, Inc., The Ohio State University, New Albany, Ohio
| | - Donald S Garbuz
- Department of Orthopaedic Surgery, University of British Columbia, Vancouver, British Columbia, Canada
| | - Daniel J Berry
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Joshua J Jacobs
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois
| |
Collapse
|
19
|
"Off-label" Usage of an Oxidized Zirconium Femoral Head in Revision of a Total Hip Arthroplasty with Mechanically Assisted Crevice Corrosion and a Legacy Taper. Arthroplast Today 2021; 8:69-73. [PMID: 33681438 PMCID: PMC7930501 DOI: 10.1016/j.artd.2021.01.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/16/2020] [Revised: 01/20/2021] [Accepted: 01/23/2021] [Indexed: 11/22/2022] Open
Abstract
We present a case of a 72-year-old male with a history of a late 1980s metal-on-polyethylene total hip arthroplasty who presented with unilateral leg vascular compromise, joint pain, and stiffness and subsequently underwent revision for adverse local tissue reaction secondary to mechanically assisted crevice corrosion. His stable and extensively porous coated femoral implant had a legacy taper with no currently manufactured option for a non–Co-alloy femoral head. After shared decision-making with the patient, we opted to use an oxidized zirconium femoral head from another manufacturer with a similar taper during his revision surgery and documented that his vascular compromise resolved and his serum Co was undetectable 3 years after the revision.
Collapse
|
20
|
Kiernan S, Kaptein B, Flivik C, Sundberg M, Flivik G. Unexpected varus deformity and concomitant metal ion release and MRI findings of modular-neck hip stems: descriptive RSA study in 75 hips with 8 years' follow-up. Acta Orthop 2021; 92:67-73. [PMID: 33297800 PMCID: PMC7919878 DOI: 10.1080/17453674.2020.1853387] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Modular-neck hip stems have been identified with corrosion-related problems from the neck-stem junction. We report an ongoing varus deformity of modular-neck hip stems with simultaneous metal ion release observed during a study comparing the migration of modular vs. standard hip stems.Patients and methods - We followed 50 patients with modular and 25 with standard neck stems using radiostereometry (RSA). At 5-year follow-up, we noted a compromised integrity of the modular stem with varus deformity in the neck-stem interface. Changes in head-tip distance as well as whole-blood ion concentration and MRI findings were analyzed. The modular stems were followed further up to 8 years.Results - The head-tip distance decreased continuously by 0.15 mm per year resulting in 1.2 (95% CI 1.0-1.4) mm at 8 years for modular stems, while for the standard stems at 5 years, the decrease was 0.09 (CI 0.0-0.2) mm or 0.02 mm/year. For the modular stems, the reduction in head-tip distance correlated to the increase in whole-blood cobalt concentration at 8 years but not to the MRI grading of tissue reactions. At 5 years, cobalt levels were 4.9 µg/L for modular stems and at 8 years 4.8 µg/L, whereas for standard stems this was 1.0 µg/L. After 8 years, 9 of 72 stems had been revised for different reasons, but only 1 with obvious adverse local tissue reaction (ALTR).Interpretation - We present a surprisingly large progressive deformation at the modular neck-stem junction, but so far without a definite clinical problem. Even the femoral head seems to show slight compression onto the taper over time. A high rate of revisions for the modular type of this stem has raised general concerns, and it has been recalled from the market.
Collapse
Affiliation(s)
- Sverrir Kiernan
- Department of Orthopedics, Skåne University Hospital, Clinical Sciences, Lund University, Lund, Sweden; ,Correspondence:
| | - Bart Kaptein
- Department of Orthopedics, Leiden University Medical Centre, Leiden, The Netherlands
| | - Carl Flivik
- Department of Orthopedics, Skåne University Hospital, Clinical Sciences, Lund University, Lund, Sweden;
| | - Martin Sundberg
- Department of Orthopedics, Skåne University Hospital, Clinical Sciences, Lund University, Lund, Sweden;
| | - Gunnar Flivik
- Department of Orthopedics, Skåne University Hospital, Clinical Sciences, Lund University, Lund, Sweden;
| |
Collapse
|
21
|
Incidence of Pseudotumors in a Dual Modular Stem Construct With and Without Metal-on-Metal Bearing Surface. J Am Acad Orthop Surg 2021; 29:e92-e97. [PMID: 32568995 DOI: 10.5435/jaaos-d-19-00652] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The purpose of this study was to compare the incidence of pseudotumors in metal-on-metal (MoM) titanium modular neck hip arthroplasties to non-MoM modular neck hip arthroplasties. A secondary goal was to determine whether a correlation exists between elevated metal concentrations and pseudotumor incidence. METHODS The data were collected and evaluated from 49 MoM joints and 26 non-MoM joints between the years 2012 and 2017. Hip ultrasonography was done after a minimum of 5 years postimplantation. Whole serum metal (titanium, cobalt, and chromium) concentrations were measured at the hip ultrasonography study. RESULTS The average time elapsed between surgery and ultrasonography visit was 7.6 years. In the 49 patients with MoM joints, 22.4% (n = 11) had a pseudotumor. In the 26 patients with non-MoM joints, 9.1% of metal-on-polyethylene hips (n = 1) and 0% of ceramic-on-ceramic/polyethylene hips developed a pseudotumor. No significant statistical correlation was observed between serum metal concentrations and pseudotumor formation (P > 0.05). A significant correlation was observed of serum titanium concentration to pseudotumor size (P = 0.024). CONCLUSION The incidence of pseudotumor formation in MoM total hip arthroplasties was more than five times the incidence associated with non-MoM bearings. The correlation between serum titanium concentration and pseudotumor size suggests that titanium levels may be a useful indicator for pseudotumor formation in patients with this particular titanium modular neck femoral implant. No notable correlation was observed between serum cobalt and chromium concentration and pseudotumor formation or size.
Collapse
|
22
|
Klemt C, Smith EJ, Oganesyan R, Limmahakhun S, Fitz D, Kwon YM. Outcome of Dual Mobility Constructs for Adverse Local Tissue Reaction Associated Abductor Deficiency in Revision Total Hip Arthroplasty. J Arthroplasty 2020; 35:3686-3691. [PMID: 32654942 DOI: 10.1016/j.arth.2020.06.043] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/23/2020] [Revised: 06/04/2020] [Accepted: 06/16/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Treatment of adverse local tissue reaction (ALTR) is challenging owing to high complications and poor outcomes after a revision surgery. As dislocation is the most common cause of reoperation, it is often necessary to use advanced articulations such as dual mobility. This study aims to evaluate the outcome and complication rates after revision surgery with dual mobility constructs, compared to constrained and conventional articulations in the setting of significant abductor deficiency due to ALTR. METHODS Out of a total of 338 revision total hip arthroplasties for ALTR, 234 patients with a significant tissue necrosis and abductor muscle insufficiency (grade 3) were evaluated. The complication rates after revisions were compared between 42 hips with dual mobility implants, 24 hips with constrained liners, 104 hips with large diameter heads (36-40 mm), and 64 hips with small diameter heads (≤32 mm). RESULTS After an average of 4 years of follow-up (2.8-8.6), the dual mobility articulation had no dislocation, compared to 4.1% and 15.5% for constrained liner and conventional articulations, respectively (P < .001). Utilization of dual mobility and constrained liner cup also did not increase the risk of nondislocation complications, including periprosthetic joint infection and periprosthetic fracture (P = .18 and .52). CONCLUSIONS This study demonstrates significantly lower dislocation rates for dual mobility when compared to conventional articulations and comparable to constrained liners in cases of severe abductor deficiency due to ALTR, suggesting that dual mobility implants are viable surgical treatment alternatives to constrained liners to minimize dislocation during revision total hip arthroplasty in the setting of significant abductor deficiency due to ALTR.
Collapse
Affiliation(s)
- Christian Klemt
- Bioengineering Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - Evan J Smith
- Bioengineering Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - Ruben Oganesyan
- Bioengineering Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - Sakkadech Limmahakhun
- Bioengineering Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - David Fitz
- Bioengineering Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - Young-Min Kwon
- Bioengineering Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| |
Collapse
|
23
|
Head-Neck Taper Corrosion in Metal-on-Polyethylene Total Hip Arthroplasty: Risk Factors, Clinical Evaluation, and Treatment of Adverse Local Tissue Reactions. J Am Acad Orthop Surg 2020; 28:907-913. [PMID: 32694319 DOI: 10.5435/jaaos-d-20-00475] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
Adverse local tissue reaction (ALTR) associated with mechanically assisted crevice corrosion of metal-on-polyethylene (MoP) head-neck modular total hip arthroplasty (THA), similarly observed in the metal-on-metal bearing, is a growing concern in MoP THA patients. Given the complex pathogenesis as well as variable clinical presentation, the diagnosis can be challenging. This article focuses on providing surgeons with an evidence-based update on (1) implant, surgical, and patient risk factors associated with ALTRs; (2) clinical systematic evaluation; and (3) surgical management options for ALTRs in MoP THA patients based on the currently available evidence.
Collapse
|
24
|
Mahajan J, Bonner B, Oganesyan R, Yeo I, Klemt C, Kwon YM. MARS MRI Characteristics of Adverse Local Tissue Reactions in Taper Corrosion of Metal-On-Polyethylene THA Differ From Metal-On-Metal THA. J Arthroplasty 2020; 35:3338-3342. [PMID: 32622715 DOI: 10.1016/j.arth.2020.06.010] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/23/2020] [Revised: 05/22/2020] [Accepted: 06/08/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Metal artifact reduction sequence (MARS) magnetic resonance imaging (MRI) has been recommended as a cross-sectional imaging modality in clinical evaluation of adverse local tissue reactions (ALTRs) in metal-on-metal (MoM) patients and metal-on-polyethylene (MoP) patients with taper corrosion. The aim of the study was to compare MARS MRI characteristics of ALTR in MoM total hip arthroplasty (THA) with ALTR in MoP THA with modular taper corrosion. METHODS A total of 197 patients with ALTR were evaluated: 86 patients with MoM THA; 37 MoP patients with head-neck taper corrosion; and 74 MoP patients with neck-stem dual taper corrosion. MARS MRI scans were evaluated to identify location, size, type of ALTR (I-III), and associated ALTR synovitis (cystic, solid, and mixed). RESULTS MARS MRI characteristics of ALTR were significantly different between the MoM and MoP groups (P = .017). The MoP group demonstrated the highest proportion of thick-walled cystic masses type II (56.7% in head-neck taper corrosion MoP and 46.5% in dual taper corrosion MoP vs 28.7% in MoM), whereas the MoM group had the highest proportion of thin-walled cystic masses type I. MoM implants (96.8%) were significantly more likely to have ALTR in multiple locations compared with both MoP groups (P = .001). CONCLUSION This study demonstrates that MARS MRI characteristics of ALTR differ by bearing type with a significantly higher percentage of mixed type and solid type ALTR in the taper corrosion MoP THA compared with MoM THA. This information provides clinically useful information in evaluation of symptomatic MoP and MoM THA patients for ALTRs.
Collapse
Affiliation(s)
- John Mahajan
- Center for Metal-on-Metal Hips and Tribocorrosion Evaluation and Treatment, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - Bryant Bonner
- Center for Metal-on-Metal Hips and Tribocorrosion Evaluation and Treatment, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - Ruben Oganesyan
- Center for Metal-on-Metal Hips and Tribocorrosion Evaluation and Treatment, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - Ingwon Yeo
- Center for Metal-on-Metal Hips and Tribocorrosion Evaluation and Treatment, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - Christian Klemt
- Center for Metal-on-Metal Hips and Tribocorrosion Evaluation and Treatment, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - Young-Min Kwon
- Center for Metal-on-Metal Hips and Tribocorrosion Evaluation and Treatment, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| |
Collapse
|
25
|
Wen Y, Vechetti IJ, Alimov AP, Hoffman JF, Vergara VB, Kalinich JF, McCarthy JJ, Peterson CA. Time-course analysis of the effect of embedded metal on skeletal muscle gene expression. Physiol Genomics 2020; 52:575-587. [PMID: 33017228 DOI: 10.1152/physiolgenomics.00096.2020] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
As a consequence of military operations, many veterans suffer from penetrating wounds and long-term retention of military-grade heavy metal fragments. Fragments vary in size and location, and complete surgical removal may not be feasible or beneficial in all cases. Increasing evidence suggests retention of heavy metal fragments may have serious biological implications, including increased risks for malignant transformation. Previous studies assessed the tumorigenic effects of metal alloys in rats, demonstrating combinations of metals are sufficient to induce tumor formation after prolonged retention in skeletal muscle tissue. In this study, we analyzed transcriptional changes in skeletal muscle tissue in response to eight different military-relevant pure metals over 12 mo. We found that most transcriptional changes occur at 1 and 3 mo after metal pellets are embedded in skeletal muscle and these effects resolve at 6 and 12 mo. We also report significant immunogenic effects of nickel and cobalt and suppressive effects of lead and depleted uranium on gene expression. Overall, skeletal muscle exhibits a remarkable capacity to adapt to and recover from internalized metal fragments; however, the cellular response to chronic exposure may be restricted to the metal-tissue interface. These data suggest that unless affected regions are specifically captured by biopsy, it would be difficult to reliably detect changes in muscle gene expression that would be indicative of long-term adverse health outcomes.
Collapse
Affiliation(s)
- Yuan Wen
- Department of Physical Therapy, College of Health Sciences, University of Kentucky, Lexington, Kentucky.,Center for Muscle Biology, University of Kentucky, Lexington, Kentucky
| | - Ivan J Vechetti
- Center for Muscle Biology, University of Kentucky, Lexington, Kentucky.,Department of Physiology, College of Medicine, University of Kentucky, Lexington, Kentucky
| | - Alexander P Alimov
- Center for Muscle Biology, University of Kentucky, Lexington, Kentucky.,Department of Physiology, College of Medicine, University of Kentucky, Lexington, Kentucky
| | - Jessica F Hoffman
- Internal Contamination and Metal Toxicity Program, Armed Forces Radiobiology Research Institute, Uniformed Services University, Bethesda, Maryland
| | - Vernieda B Vergara
- Internal Contamination and Metal Toxicity Program, Armed Forces Radiobiology Research Institute, Uniformed Services University, Bethesda, Maryland
| | - John F Kalinich
- Internal Contamination and Metal Toxicity Program, Armed Forces Radiobiology Research Institute, Uniformed Services University, Bethesda, Maryland
| | - John J McCarthy
- Center for Muscle Biology, University of Kentucky, Lexington, Kentucky.,Department of Physiology, College of Medicine, University of Kentucky, Lexington, Kentucky
| | - Charlotte A Peterson
- Department of Physical Therapy, College of Health Sciences, University of Kentucky, Lexington, Kentucky.,Center for Muscle Biology, University of Kentucky, Lexington, Kentucky
| |
Collapse
|
26
|
Mechanically Assisted Crevice Corrosion in a Metal-on-Polyethylene Total Hip Presenting With Lower Extremity Vascular Compromise. Arthroplast Today 2020; 6:445-450. [PMID: 32637514 PMCID: PMC7327377 DOI: 10.1016/j.artd.2020.04.015] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/28/2020] [Revised: 04/18/2020] [Accepted: 04/23/2020] [Indexed: 11/22/2022] Open
Abstract
Mechanically assisted crevice corrosion in modular total hip replacements may lead to an adverse local tissue reaction (ALTR) with a variety of sequelae. Although an ALTR is most commonly recognized with metal-on-metal modular hip constructs, tribocorrosion at the head-neck junction of metal-on-polyethylene (MoP) total hip arthroplasties may also lead to an ALTR. We present a case of a 79-year-old woman with a history of MoP total hip arthroplasty who presented with unilateral leg swelling, joint pain, and stiffness and subsequently underwent revision for an ALTR secondary to mechanically assisted crevice corrosion. This unique case of lower extremity vascular compromise resulting from an ALTR is important because clinicians should consider corrosion-related ALTRs when treating patients with an MoP hip prosthesis presenting with new-onset lower extremity swelling.
Collapse
|
27
|
Hall DJ, Pourzal R, Jacobs JJ. What Surgeons Need to Know About Adverse Local Tissue Reaction in Total Hip Arthroplasty. J Arthroplasty 2020; 35:S55-S59. [PMID: 32005621 PMCID: PMC7239747 DOI: 10.1016/j.arth.2020.01.016] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/06/2020] [Accepted: 01/07/2020] [Indexed: 02/01/2023] Open
Abstract
Adverse local tissue reactions (ALTRs) were first associated with patients with failed metal-on-metal surface replacements and total hip arthroplasty (THA). However, an increasing number of cases of ALTR in metal-on-polyethylene (MOP) THA patients is being reported. Clinically, ALTR appears as benign, aseptic masses or bursae in the periprosthetic tissues. Histopathologically, ALTRs are distinguished by an intense lymphocyte infiltrate, destruction of the synovial surfaces, widespread necrosis, and fibrin exudate. Tribocorrosion of modular junctions appears to be the cause of ALTR in MOP patients. The various tribocorrosion damage modes occurring at modular junctions produce metal ions and a diversity of particulates in relation to size, chemical composition, and structure. The mechanisms by which these various products of tribocorrosion lead to ALTR are still a matter of considerable research. This review clarifies what constitutes ALTR, its relationship to implant factors, and highlights current methods for diagnosis and management of patients with ALTR in the setting of MOP THA.
Collapse
Affiliation(s)
- Deborah J Hall
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL
| | - Robin Pourzal
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL
| | - Joshua J Jacobs
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL
| |
Collapse
|
28
|
Abstract
BACKGROUND Modern total hip arthroplasty has seen an unfortunate increase in proportional implant failures secondary to adverse local tissue reactions (ALTRs) secondary to wear of metal-on-metal (MoM) bearings and mechanically assisted crevice corrosion (MACC) related to corrosion at implant junctions and tapers. The purpose of this study is to describe the appropriate choice of metal ion testing and evaluation of those levels to identify failed total hip arthroplasty implants containing cobalt and chromium. METHODS When presented with an arthroplasty of concern, the surgeon must determine what metal ion levels to obtain and then incorporate those levels into a treatment algorithm. Patients with painful hip arthroplasties are evaluated for chromium and cobalt by obtaining whole blood and synovial metal levels. RESULTS Synovial fluid cobalt had the highest correlation with ALTR compared with the other tests, with a threshold of 19.75 ng/ml, with a specificity of 89%, if the cobalt-to-chromium ratio is greater than 1.4 ng/ml in a metal on polyethylene hip, with a sensitivity of 95%. CONCLUSION The interpretation of whole blood metal ions is a key component of the algorithm in treating the symptomatic hip arthroplasty but is not to be used in a vacuum.
Collapse
|
29
|
Kwon YM. Adverse Local Tissue Reactions in Total Hip Arthroplasty: Who, When, and How to Revise. J Arthroplasty 2020; 35:S53-S54. [PMID: 31973968 DOI: 10.1016/j.arth.2019.12.042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/20/2019] [Accepted: 12/29/2019] [Indexed: 02/01/2023] Open
Affiliation(s)
- Young-Min Kwon
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| |
Collapse
|
30
|
McGrory BJ, Jacobs JJ, Kwon YM, Fillingham Y. Standardizing terms for tribocorrosion-associated adverse local tissue reaction in total hip arthroplasty. Arthroplast Today 2020; 6:196-200. [PMID: 32577461 PMCID: PMC7303482 DOI: 10.1016/j.artd.2020.01.008] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/04/2020] [Revised: 01/19/2020] [Accepted: 01/21/2020] [Indexed: 02/08/2023] Open
Abstract
Recognizing and adopting standardized terms for adverse local tissue reaction associated with tribocorrosion in total hip arthroplasty are essential for clear scientific discourse and clinical communication. Our goal was to develop terms that can be broadly applied to characterize the local tissue response to tribocorrosion debris, based on current evidence regarding the etiology of this failure mode and its consequences. The proposed standardized terms will improve the understanding and interpretation of analytical tests, advance diagnostic and treatment algorithms, and reduce confusion in research by maintaining consistent nomenclature.
Collapse
Affiliation(s)
- Brian J. McGrory
- Corresponding author. Department of Orthopaedic Surgery, Tufts University School of Medicine, Boiston, MA, USA; Maine Medical Center Division of Joint Replacements, Portland, ME, USA. Tel.: +1 207 781 1551.
| | - Joshua J. Jacobs
- Department of Orthopaedic Surgery, Tufts University School of Medicine, Boston, MA, USA
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, MA, USA
| | - Young-Min Kwon
- Department of Orthopaedic Surgery, Tufts University School of Medicine, Boston, MA, USA
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, MA, USA
| | - Yale Fillingham
- Department of Orthopaedic Surgery, Tufts University School of Medicine, Boston, MA, USA
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, MA, USA
| |
Collapse
|
31
|
Bonner B, Arauz P, Klemt C, Kwon YM. Outcome of Re-Revision Surgery for Adverse Local Tissue Reaction in Metal-on-Polyethylene and Metal-on-Metal Total Hip Arthroplasty. J Arthroplasty 2020; 35:S284-S288. [PMID: 32113811 DOI: 10.1016/j.arth.2020.02.006] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/27/2019] [Revised: 01/27/2020] [Accepted: 02/04/2020] [Indexed: 02/08/2023] Open
Abstract
BACKGROUND Adverse local tissue reactions (ALTRs), initially described as a complication of metal-on-metal (MoM) total hip arthroplasty (THA), have also become an important risk factor for implant failure requiring revision surgery in metal-on-polyethylene (MoP) THA due to modular taper corrosion. This study aims to report early complication rates and outcomes as well as potential risk factors for a re-revision. METHODS A total of 252 consecutive THA patients who underwent revision for ALTR were reviewed. There were 40 patients (16%) who underwent a second revision: (1) 26 MoP patients with modular taper corrosion and (2) 14 MoM patients. Patient demographics as well as clinical information were analyzed. Binary logistic regression was used to test for associations between re-revision surgery and clinical parameters. RESULTS The overall complication rate following initial revision for ALTR was 21%. Sixteen percent of these revision patients required a re-revision. The most common indication for re-revision was dislocation (45%). The complication rate was 35% following a re-revision which included dislocation (36%), infection (36%), fracture (14%), and implant loosening (14%). The rate of patients requiring a third revision was 23% with the most common indications being dislocation (33%) and infection (33%) (P = .032). CONCLUSION High rate of early complications (35%) and third revisions (23%) were observed following re-revision of symptomatic ALTR patients with those requiring re-revision associated with extensive intraoperative tissue necrosis. These findings provide clinically useful information that may assist surgeons in clinical decision making and preoperative counseling of both MoM and MoP patients undergoing re-revision surgery for ALTR.
Collapse
Affiliation(s)
- Bryant Bonner
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - Paul Arauz
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - Christian Klemt
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - Young-Min Kwon
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| |
Collapse
|
32
|
Grupp TM, Baxmann M, Jansson V, Windhagen H, Heller KD, Morlock MM, Knaebel HP. How to proceed with asymptomatic modular dual taper hip stems in the case of acetabular revision. MATERIALS 2020; 13:ma13051098. [PMID: 32121627 PMCID: PMC7084958 DOI: 10.3390/ma13051098] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/28/2019] [Revised: 02/13/2020] [Accepted: 02/18/2020] [Indexed: 12/15/2022]
Abstract
How to proceed with a clinically asymptomatic modular Metha® Ti alloy stem with dual taper CoCr neck adapter in case of acetabular revision? To systematically answer this question the status of research and appropriate diagnostic methods in context to clinically symptomatic and asymptomatic dual taper stem-neck couplings has been evaluated based on a systematic literature review. A retrieval analysis of thirteen Metha® modular dual taper CoCr/Ti alloy hip stems has been performed and a rational decision making model as basis for a clinical recommendation was developed. From our observations we propose that in cases of acetabular revision, that for patients with a serum cobalt level of > 4 µg/L and a Co/Cr ratio > 3.6, the revision of the modular dual taper stem may be considered. Prior to acetabular revision surgery a systematic diagnostic evaluation should be executed, using specific tests such as serum metal (Co, Cr) ion analysis, plain antero-posterior and lateral radiographs and cross-sectional imaging modalities (Metal Artefact Reduction Sequence Magnetic Resonance Imaging). For an asymptomatic Metha® dual taper Ti alloy/CoCr stem-neck coupling at the stage of acetabular revision careful clinical decision making according to the proposed model should be followed and overreliance on any single examination should be avoided, considering the complete individual differential diagnosis and patient situation.
Collapse
Affiliation(s)
- Thomas M. Grupp
- Aesculap AG Research & Development, 78532 Tuttlingen, Germany;
- Department of Orthopaedic Surgery, Physical Medicine & Rehabilitation, Campus Grosshadern Ludwig Maximilians University Munich, 81377 Munich, Germany;
- Correspondence: ; Tel.: +49-7461-95-2667; Fax: +49-7461-95-382667
| | - Marc Baxmann
- Aesculap AG Research & Development, 78532 Tuttlingen, Germany;
| | - Volkmar Jansson
- Department of Orthopaedic Surgery, Physical Medicine & Rehabilitation, Campus Grosshadern Ludwig Maximilians University Munich, 81377 Munich, Germany;
| | - Henning Windhagen
- Department of Orthopaedic Surgery, Hannover Medical School, 30625 Hannover, Germany;
| | - Karl-Dieter Heller
- Department of Orthopaedic Surgery, Herzogin-Elisabeth-Hospital, 38124 Braunschweig, Germany;
| | - Michael M. Morlock
- Institute of Biomechanics, TUHH Hamburg University of Technology, 21073 Hamburg, Germany;
| | | |
Collapse
|
33
|
Lützner J, Günther KP, Postler A, Morlock M. Metal Ion Release after Hip and Knee Arthroplasty - Causes, Biological Effects and Diagnostics. ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE 2019; 158:369-382. [PMID: 31820432 DOI: 10.1055/a-0929-8121] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
All metal implants in human bodies corrode which results in metal ions release. This is not necessarily a problem and represents for most patients no hazard. However, if a critical metal ion concentration is exceeded, local or rarely systemic problems can occur. This article summarizes the mechanisms of metal ion release and its clinical consequences. Several situations can result in increased metal ion release: metal-on-metal hip arthroplasties with increased wear, increased micromotion at taper interfaces, direct metal-metal contact (polyethylene wear, impingement), erroneously used metal heads after ceramic head fracture. Possible problems are in most cases located close to the concerned joint. Furthermore, there are reports about toxic damage to several organs. Most of these reports refer to erroneously used metal heads in revisions after a broken ceramic head. There is currently no evidence of carcinogenic or teratogenic effects of implants but data is not sufficient to exclude possible effects. Cobalt and chromium blood levels (favorably in whole blood) should be measured in patients with suspected elevated metal ions. According to current knowledge levels below 2 µg/l seem to be uncritical, levels between 2 and 7 µg/l are considered borderline with unknown biological consequences and levels above 7 µg/l indicate a local problem which should be further diagnosed. Metal ion levels always need to be interpreted together with clinical symptoms and imaging results.
Collapse
Affiliation(s)
- Jörg Lützner
- University Center of Orthopaedics and Trauma Surgery, TU Dresden
| | | | - Anne Postler
- University Center of Orthopaedics and Trauma Surgery, TU Dresden
| | | |
Collapse
|
34
|
Affiliation(s)
- Mengnai Li
- Department of Orthopaedics, Wexner Medical Center, The Ohio State University, Columbus, Ohio
| | - Andrew Glassman
- Department of Orthopaedics, Wexner Medical Center, The Ohio State University, Columbus, Ohio
| |
Collapse
|