1
|
Nam HS, Pei Yuik Ho J, Park SY, Cho JH, Lee YS. Development of a machine learning model for identifying the optimal situation favoring double-level osteotomy over single-level high tibial osteotomy. Knee 2024; 47:196-207. [PMID: 38417191 DOI: 10.1016/j.knee.2024.02.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Revised: 01/22/2024] [Accepted: 02/07/2024] [Indexed: 03/01/2024]
Abstract
BACKGROUND This study aimed to develop a machine learning (ML) model to identify the optimal situation wherein double-level osteotomy (DLO) is favored for severe varus knees by analyzing unfavorable outcomes. This study hypothesized that there are the most favorable algorithms and contributing factors for identifying the optimal situation favoring DLO over opening-wedge high tibial osteotomy (OWHTO). METHODS Data were retrospectively collected from patients who underwent OWHTO (505 knees). Unfavorable outcome parameters were defined as follows: (1) medial proximal tibial angle (MPTA) > 95°, (2) joint line convergence angle (JLCA) > 4° (insufficient medial release), (3) JLCA < 0° (medial instability), (4) recurrence of varus deformity, and (5) lateral hinge fracture. The input data for the ML model included demographic data and preoperative radiological and intra-operative factors. The ML model was used to evaluate overall and to evaluate each unfavorable outcome. Interpretation by the model was performed by SHapley Additive exPlanations. RESULTS The unfavorable group had a larger JLCA and MPTA preoperatively than the favorable group in the conventional comparison. The light gradient boosting machine (LGBM) demonstrated the highest AUC of 0.66 and F-1 score of 0.72 among the ML algorithms. In the overall assessment, the preoperative weight-bearing line ratio (WBLR) was the factor that contributed the most, followed by the preoperative JLCA and the ΔWBLR. ΔWBLR and the preoperative JLCA were the contributing factors for each outcome. CONCLUSIONS The LGBM model was superior in predicting the optimal situations favoring DLO over OWHTO. Preoperative WBLR, preoperative JLCA, and ΔWBLR significantly contributed to the unfavorable outcomes overall and for each outcome in the ML model.
Collapse
Affiliation(s)
- Hee Seung Nam
- Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seoul, South Korea
| | - Jade Pei Yuik Ho
- Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seoul, South Korea
| | - Seung Yun Park
- Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seoul, South Korea
| | - Joon Hee Cho
- Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seoul, South Korea
| | - Yong Seuk Lee
- Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seoul, South Korea.
| |
Collapse
|
2
|
Kim SM, Bin SI, Kim JM, Lee BS, Lee HY, Lee SJ. Lateral Distance From the Osteotomy Hinge Point to the Tibial Cortex Is Associated With Lateral Hinge Fracture Type and Fracture Occurrence Time After Medial Open-Wedge High Tibial Osteotomy. Arthroscopy 2024; 40:890-895. [PMID: 37586667 DOI: 10.1016/j.arthro.2023.07.054] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Revised: 07/21/2023] [Accepted: 07/27/2023] [Indexed: 08/18/2023]
Abstract
PURPOSE To verify whether the distance from the hinge point to the tibial cortex affects the occurrence time and characteristics of the lateral hinge fracture (LHF) in medial open-wedge high tibial osteotomy. METHODS We retrospectively reviewed 171 knees in 171 patients (121 women, 50 men; mean age, 53.9 years; range, 36-67 years) who had undergone medial open-wedge high tibial osteotomy with locking plate fixation between January 2011 and December 2020. Osteotomy hinge point and LHFs were identified on intraoperative fluoroscopy and immediate postoperative radiographs. LHF type was classified as suggested by Takeuchi et al. Acute fracture was defined as a fracture that occurred during surgery, and delayed fracture was defined as a fracture observed after 1 month postoperatively. The nearest distances from osteotomy hinge point to lateral, distal, and proximal cortex were measured on postoperative radiographs. We compared the distance between the different types and between acute and delayed LHFs. RESULTS There were 55 LHFs (32%) (type I, 40 knees; type II, 14 knees; type III, 1 knee) that occurred acutely in 41 knees and were found as delayed fractures in 14 knees. The patient demographics were not significantly different between non-LHFs and each type of LHFs. Proximal and distal distances were not statistically different among fracture types and between occurrence times. However, lateral distances were significantly shorter in type I LHFs (6.2 ± 1.8 mm) and longer in type II LHFs (9.3 ± 2.3 mm) than in non-LHFs (7.1 ± 2.7 mm) (P = .020 and .004, respectively). The lateral cortical distances were also different between acute LHFs (6.4 ± 1.9 mm) and delayed LHF (9.0 ± 2.7 mm) (P < .001). In the case of fracture type, the frequency of type I decreases with increase in the lateral distance, whereas that of type II increases with increase in the lateral cortical distance. In acute fracture, type I was dominant (85.4%), whereas in delayed fracture, type II was dominant (57.2%). CONCLUSIONS The lateral cortical distance from the hinge point was significantly associated with LHF occurrence. Shorter distance increased the risk for acute type I LHF, whereas longer distance increased the risk for delayed type II LHFs. LEVEL OF EVIDENCE Level III, retrospective comparative prognostic trial.
Collapse
Affiliation(s)
- Seung-Min Kim
- Department of Orthopaedic Surgery, Wiltse Memorial Hospital, Anyang, Republic of Korea
| | - Seong-Il Bin
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
| | - Jong-Min Kim
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
| | - Bum-Sik Lee
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
| | - Hyo-Yeol Lee
- Department of Orthopaedic Surgery, Eulji Medical Center Daejeon Hospital, Eulji University College of Medicine, Daejeon, Republic of Korea
| | - Seon-Jong Lee
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
| |
Collapse
|
3
|
Meisterhans M, Flury A, Zindel C, Zimmermann SM, Vlachopoulos L, Snedeker JG, Fucentese SF. Finite element analysis of medial closing and lateral opening wedge osteotomies of the distal femur in relation to hinge fractures. J Exp Orthop 2023; 10:33. [PMID: 36973592 PMCID: PMC10043162 DOI: 10.1186/s40634-023-00597-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/06/2023] [Accepted: 03/10/2023] [Indexed: 03/29/2023] Open
Abstract
PURPOSE Intraoperative hinge fractures in distal femur osteotomies represent a risk factor for loss of alignment and non-union. Using finite element analysis, the goal of this study was to investigate the influence of different hinge widths and osteotomy corrections on hinge fractures in medial closed-wedge and lateral open-wedge distal femur osteotomies. METHODS The hinge was located at the proximal margin of adductor tubercle for biplanar lateral open-wedge and at the upper border of the lateral femoral condyle for biplanar medial closed-wedge distal femur osteotomies, corresponding to optimal hinge positions described in literature. Different hinge widths (5, 7.5, 10 mm) were created and the osteotomy correction was opened/closed by 5, 7.5 and 10 mm. Tensile and compressive strain of the hinge was determined in a finite element analysis and compared to the ultimate strain of cortical bone to assess the hinge fracture risk. RESULTS Doubling the correction from 5 to 10 mm increased mean tensile and compressive strain by 50% for lateral open-wedge and 48% for medial closed-wedge osteotomies. A hinge width of 10 mm versus 5 mm showed increased strain in the hinge region of 61% for lateral open-wedge and 32% for medial closed-wedge osteotomies. Medial closed-wedge recorded a higher fracture risk compared to lateral open-wedge osteotomies due to a larger hinge cross-section area (60-67%) for all tested configurations. In case of a 5 mm hinge, medial closed-wedge recorded 71% higher strain in the hinge region compared to lateral open-wedge osteotomies. CONCLUSION Due to morphological features of the medial femoral condyle, finite element analysis suggests that lateral-open wedge osteotomies are the preferable option if larger corrections are intended, as a thicker hinge can remain without an increased hinge fracture risk.
Collapse
Affiliation(s)
- Michel Meisterhans
- Department of Orthopedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.
| | - Andreas Flury
- Department of Orthopedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
| | - Christoph Zindel
- Department of Orthopedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
| | - Stefan M Zimmermann
- Department of Orthopedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
| | - Lazaros Vlachopoulos
- Department of Orthopedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
| | - Jess G Snedeker
- Department of Orthopedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
- Institute for Biomechanics, ETH Zurich, Zurich, Switzerland
| | - Sandro F Fucentese
- Department of Orthopedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
| |
Collapse
|
4
|
Fujita K, Sawaguchi T, Goshima K, Shigemoto K, Iwai S. Influence of lateral hinge fractures on biplanar medial closing-wedge distal femoral osteotomy for valgus knee: a new classification of lateral hinge fracture. Arch Orthop Trauma Surg 2023; 143:1175-1183. [PMID: 34655322 DOI: 10.1007/s00402-021-04212-4] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Accepted: 10/03/2021] [Indexed: 10/20/2022]
Abstract
BACKGROUND The purpose of this study was to examine the influence of lateral hinge fractures in medial closing-wedge distal femoral osteotomy (MCWDFO) on bone union. METHODS Twenty-one patients were followed-up for more than 1 year after MCWDFO. The incidence and type of hinge fracture, as well as the course of bone healing, were investigated. Slow healing was defined as bone union was not obtained until 3 months after surgery. RESULTS Hinge fractures were observed in 12 cases (57%). There were three types of hinge fractures. Type 1: the lateral cortex was completely cut through (4 cases), type 2: the osteotomy line was too proximal (6 cases), and type 3: the hinge point was significantly medial (2 cases). There was a significant difference in the mean correction angles between hinge fracture and no-fracture cases, with the mean angles being 13.8 ± 4.0° and 9.6 ± 3.1°, respectively. Sixty-seven percent (8/12) of cases with hinge fractures developed slow healing. Among the hinge fracture cases, when there was no displacement of the hinge fracture and good contact with the anterior flange, 40% (2/5) of cases developed slow healing. If there was displacement of the hinge or no contact of the anterior flange, 86% (6/7) of cases developed slow healing. In contrast, only 11% (1/9) of subjects who did not have a hinge fracture, developed slow healing. In 67% (6/9) of cases with slow healing, a correction loss of 2° or greater (average: 4.3 degrees valgus) was observed. There were no cases of non-union. Clinical outcomes at 1 year showed no significant difference between the groups with and without hinge fractures. CONCLUSIONS There is a very high risk of hinge fracture in patients undergoing MCWDFO. Hinge fractures often lead to slow healing and a loss of correction. We recommend the endpoint of the distal lateral cortex of the femur as the ideal hinge point for the prevention of hinge fractures. Bone union is obtained slowly in even all hinge fracture cases without revision surgery. Consequently, surgical results are not affected by the occurrence of hinge fracture at 1 year.
Collapse
Affiliation(s)
- Kenji Fujita
- Department of Orthopedic Surgery and Joint Reconstructive Surgery, Toyama Municipal Hospital, 2-1 Imaizumi Hokubu-machi, Toyama, 939-8511, Japan. .,Department of Orthopedic Surgery, Ishikawa Prefectural Central Hospital, 2-1 Kuratsukihigashi, Kanazawa, Ishikawa, 920-8530, Japan.
| | - Takeshi Sawaguchi
- Department of Traumatology, Fukushima Medical University, 1 Hikariga-oka, Fukushima, 960-1295, Japan.,Trauma Reconstruction Center, Shinyurigaoka General Hospital, 255 Furusawa Asao-ku, Kawasaki, Kanazawa, 215-0026, Japan
| | - Kenichi Goshima
- Department of Orthopedic Surgery, Kanazawa Munehiro Hospital, 24-30 Sakura-machi, Kanazawa, Ishikawa, 920-0923, Japan
| | - Kenji Shigemoto
- Department of Orthopedic Surgery and Joint Reconstructive Surgery, Toyama Municipal Hospital, 2-1 Imaizumi Hokubu-machi, Toyama, 939-8511, Japan
| | - Shintaro Iwai
- Department of Orthopedic Surgery and Joint Reconstructive Surgery, Toyama Municipal Hospital, 2-1 Imaizumi Hokubu-machi, Toyama, 939-8511, Japan
| |
Collapse
|
5
|
Park YH, Lee HJ, Choi JW, Kim HJ. Value of postoperative computed tomography for the diagnosis of lateral hinge fracture in medial opening-wedge supramalleolar osteotomy. Arch Orthop Trauma Surg 2023; 143:1379-1385. [PMID: 35039915 DOI: 10.1007/s00402-021-04301-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/15/2021] [Accepted: 12/02/2021] [Indexed: 11/02/2022]
Abstract
INTRODUCTION It remains unclear whether computed tomography (CT) is superior to plain radiography in detecting lateral hinge fractures after medial opening-wedge supramalleolar osteotomy (SMO) of the ankle joint. This study aimed to evaluate the disparity between postoperative plain radiography and CT in detecting lateral hinge fractures after medial opening-wedge SMO and to identify the predictive factors of lateral hinge fractures. MATERIALS AND METHODS This retrospective study included 39 patients who underwent medial opening-wedge SMO. The immediate postoperative plain radiography and CT scan images were retrieved, and the presence of lateral hinge fractures was independently determined. Depending on the fracture gap, the lateral hinge fractures were subclassified as stable (gap < 2 mm) or unstable (gap ≥ 2 mm) fractures. To investigate the predictive factors, the cases were divided based on diagnostic tools such as plain radiography and CT. RESULTS The incidence of lateral hinge fractures was 48.7% (19/39) on plain radiographs and 61.5% (24/39) on CT scans. Five cases of lateral hinge fractures additionally detected on CT scans were stable fractures, and all had been classified as no fracture on plain radiographs. The unstable fractures that had been subclassified based on plain radiographs did not change on CT scans. None of the variables were associated with the presence of lateral hinge fractures on plain radiographs and CT scans. CONCLUSIONS Postoperative CT after medial opening-wedge SMO has no additional diagnostic value if the lateral hinge fracture has already been diagnosed on plain radiography. Therefore, postoperative CT is only recommended when lateral hinge fractures are not visible on plain radiographs.
Collapse
Affiliation(s)
- Young Hwan Park
- Department of Orthopaedic Surgery, Korea University Guro Hospital, 148 Gurodong-ro, Guro-gu, Seoul, 08308, Korea
| | - Ho Jae Lee
- Department of Orthopaedic Surgery, Korea University Guro Hospital, 148 Gurodong-ro, Guro-gu, Seoul, 08308, Korea
| | - Jung Woo Choi
- Department of Orthopaedic Surgery, Korea University Guro Hospital, 148 Gurodong-ro, Guro-gu, Seoul, 08308, Korea
| | - Hak Jun Kim
- Department of Orthopaedic Surgery, Korea University Guro Hospital, 148 Gurodong-ro, Guro-gu, Seoul, 08308, Korea.
| |
Collapse
|
6
|
Morita Y, Kuriyama S, Yamawaki Y, Nakamura S, Nishitani K, Ito H, Matsuda S. Opening-Wedge High Tibial Osteotomy With High Hinge Position Risks Lateral Hinge Fracture in Men With Posterolateral Tibial Condyle Protrusion. Arthroscopy 2023; 39:324-334. [PMID: 35961443 DOI: 10.1016/j.arthro.2022.07.018] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/04/2022] [Revised: 07/04/2022] [Accepted: 07/13/2022] [Indexed: 02/02/2023]
Abstract
PURPOSE The primary aim of this study was to evaluate the 3-dimensional morphology of the proximal tibia around the osteotomy plane in open-wedge high tibial osteotomy, focusing on the posterolateral (PL) and posteromedial (PM) tibial condyles, and to clarify the changes in morphologic parameters due to differences in patient characteristics and hinge position. The secondary aim was to examine whether morphologic features were associated with insufficient osteotomy, which increases the risk of lateral hinge fracture (LHF). METHODS The PL and PM anteroposterior distance, asymmetry ratio, and discrepancy between PL and PM distances along the tibial osteotomy plane were measured. We investigated changes in the parameters due to differences in patient characteristics and hinge position. Osteotomy configurations and LHFs were evaluated using postoperative computed tomography scans. RESULTS The 3-dimensional preoperative plans of 117 knees (male, 41 knees; female, 76 knees) were evaluated. PL distances were larger than PM distances in almost all cases. The average asymmetry ratio was 1.35, and the standard deviation was 0.22. Higher hinge position was associated with a larger asymmetry ratio and discrepancy (P < .001). The asymmetry ratio and discrepancy were independently positively correlated with male sex (P = .002 and P = .001, respectively) and gentle posterior tibial slope (P < .001 and P < .001, respectively). Osteotomies with type III LHFs showed lower osteotomy sufficiency than osteotomies without LHFs (P < .001). CONCLUSIONS PL tibial condyle protrusion was more pronounced in male patients and those with a high hinge position, and may result in insufficient PL osteotomy, which is a risk factor for type III LHF during open-wedge high tibial osteotomy. The optimal hinge position was located approximately 15 mm and 20 mm distal to the lateral tibial plateau in female and male patients, respectively. LEVEL OF EVIDENCE IV: retrospective case series.
Collapse
Affiliation(s)
- Yugo Morita
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, Kyoto
| | - Shinichi Kuriyama
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, Kyoto.
| | - Yusuke Yamawaki
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, Kyoto
| | - Shinichiro Nakamura
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, Kyoto
| | - Kohei Nishitani
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, Kyoto
| | - Hiromu Ito
- Department of Orthopaedic Surgery, Kurashiki Central Hospital, Kurashiki, Japan
| | - Shuichi Matsuda
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, Kyoto
| |
Collapse
|
7
|
Nha KW, Kim HS, Jin DU, Bae JH, Patel JM, Kim SG. Predictive Factors for Lateral Hinge Fracture in Medial Closing Wedge Distal Femoral Osteotomy. Am J Sports Med 2022; 50:3819-3826. [PMID: 36326293 DOI: 10.1177/03635465221131527] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND Recent studies have reported that lateral hinge fracture (LHF) has a negative effect on bone healing at the osteotomy site after medial closing wedge distal femoral osteotomy (MCDFO). However, limited evidence exists in the literature regarding the predictive factors for LHF in MCDFO. HYPOTHESIS A large medial closing gap and a lateral hinge position in the supracondylar area would increase plain radiography-based and/or computed tomography (CT)-based LHF in MCDFO. STUDY DESIGN Case control study; Level of evidence, 3. METHODS We retrospectively evaluated 67 knees of 53 patients (mean age, 37.4 ± 16.9 years) who underwent MCDFO between May 2009 and June 2021. The surgical indications for MCDFO were genu valgum deformity combined with either lateral compartment osteoarthritis or recurrent patellar dislocation. The presence of LHF was evaluated based on immediate postoperative plain radiography and CT scans. The predictive factors for LHF in MCDFO were investigated using multivariate logistic regression analysis. RESULTS LHFs were identified in 21 knees (31.3%) through plain radiography and in 40 knees (59.7%) through CT. Multivariate logistic regression analysis showed that the medial closing gap and lateral hinge position were predictive factors for plain radiography- and CT-based LHF after MCDFO. Controlling for other variables, we found that an increase in the medial opening gap by 1 mm increased the likelihood of plain radiography-based LHF by a factor of 1.805 (95% CI, 1.291-2.525; P = .001) and CT-based LHF by 1.333 (95% CI, 1.003-1.772; P = .048). Moreover, a lateral hinge position in the supracondylar area increased the likelihood of plain radiography-based LHF by a factor of 9.870 (95% CI, 2.179-44.720; P = .003) and CT-based LHF by 5.686 (95% CI, 1.124-28.754; P = .036). CONCLUSION A large medial closing gap and lateral hinge position in the supracondylar area are associated with LHF in MCDFO. Care should be taken to prevent LHF in MCDFO with a large medial closing gap. Moreover, a lateral hinge position in the supracondylar area should be avoided to decrease the incidence of LHF in MCDFO.
Collapse
Affiliation(s)
- Kyung Wook Nha
- Department of Orthopaedic Surgery, Inje University Ilsan Paik Hospital, Gyeongki-do, Republic of Korea
| | - Hyung Suh Kim
- Department of Orthopaedic Surgery, Inje University Ilsan Paik Hospital, Gyeongki-do, Republic of Korea
| | - Dong Uk Jin
- Department of Orthopaedic Surgery, National Medical Center, Seoul, Republic of Korea
| | - Ji Hoon Bae
- Department of Orthopaedic Surgery, Korea University Guro Hospital, Seoul, Republic of Korea
| | - Jaykumar M Patel
- Department of Orthopaedic Surgery, Jay Orthopaedic Hospital and Arthroscopy Centre, Shahibaug, Ahmedabad City, India
| | - Sang-Gyun Kim
- Department of Orthopaedic Surgery, National Medical Center, Seoul, Republic of Korea
| |
Collapse
|
8
|
Song JH, Bin SI, Kim JM, Lee BS, Park JG, Lee SM. Risk Factors for Increase in Posterior Slope After Medial Open-Wedge High Tibial Osteotomy. Orthop J Sports Med 2022; 10:23259671221137042. [PMID: 36419475 PMCID: PMC9676332 DOI: 10.1177/23259671221137042] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Accepted: 08/30/2022] [Indexed: 09/08/2023] Open
Abstract
BACKGROUND Whether lateral hinge fracture (LHF) after open-wedge high tibial osteotomy (OWHTO) is associated with the change in tibial posterior slope (PS) has not been determined. Risk factors for PS increase are still unknown. HYPOTHESIS There will be no difference in patient characteristics and radiographic factors when stratified by change in tibial PS (ΔPS). STUDY DESIGN Cohort study; Level of evidence, 3. METHODS We reviewed the records of 148 patients who underwent OWHTO with locking-plate fixation from 2010 to 2016. Included were those with a minimum 2-year follow-up and true lateral radiographs before and at 1 year after surgery. ΔPS was defined as a difference between preoperative and 1-year postoperative PS, with positive values indicating PS increase. ΔPS was classified into <3°, 3° to <6°, and ≥6°. Any LHFs were grouped by Takeuchi classification as stable (type 1) or unstable (types 2 and 3). Risk factors for PS increase were evaluated using ordinal logistic regression analyses. Clinical outcomes according to ΔPS were evaluated using the Hospital for Special Surgery score. RESULTS There were 79 (53.4%) patients with ΔPS <3°, 44 (29.7%) with 3° ≤ ΔPS < 6°, and 25 (16.9%) with ΔPS ≥6°. LHFs were observed in 41 (27.7%) patients: 32 with type 1 and 7 and 2 with types 2 and 3, respectively. Results of the multivariate ordinal logistic regression analysis indicated that ΔPS was associated with unstable LHF (P = .005, exp[β] = 6.34), preoperative PS (P = .028, exp[β] = 0.90), and correction angle (P = .037, exp[β] = 1.09). ΔPS ≥6° was seen in 4 of 9 (44.4%) patients with unstable LHF, 9 of 32 (28.1%) with stable LHF, and 12 of 107 (11.2%) with no LHF (P = .017). The mean correction angle was 11.3° ± 3.6° in patients with ΔPS ≥6°, 9.4° ± 4.6° in cases of 3° ≤ ΔPS < 6°, and 8.8° ± 3.6° in cases of ΔPS <3° (P = .019). Hospital for Special Surgery scores did not differ according to ΔPS. CONCLUSION LHF type and correction angle were associated with ΔPS after OWHTO, and unstable LHF and large correction angle were risk factors for PS increase. There was no significant difference in clinical outcomes according to ΔPS.
Collapse
Affiliation(s)
- Ju-Ho Song
- Department of Orthopedic Surgery, Chungnam National University Sejong Hospital, Chungnam National University College of Medicine, Sejong, Republic of Korea
| | - Seong-Il Bin
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
| | - Jong-Min Kim
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
| | - Bum-Sik Lee
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
| | - Jun-Gu Park
- Department of Orthopedic Surgery, Anam Hospital, College of Medicine, Korea University, Seoul, Republic of Korea
| | - Sang-Min Lee
- Department of Orthopedic Surgery, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Yangsan, Republic of Korea
| |
Collapse
|
9
|
Shim SJ, Jeong HW, Kim S, Park YG, Lee YS. Factors Associated With Unfavorable Radiological Outcomes After Opening-Wedge High Tibial Osteotomy for Varus Knees. Orthop J Sports Med 2022; 10:23259671221136501. [PMID: 36452340 PMCID: PMC9703515 DOI: 10.1177/23259671221136501] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Accepted: 08/30/2022] [Indexed: 10/15/2023] Open
Abstract
BACKGROUND Corrective osteotomy around the knee is based on deformity profiles of the femoral and tibial sides. Opening-wedge high tibial osteotomy (OWHTO) can be favored if the outcomes are not different, even if there is a certain degree of abnormal parameters after correction. PURPOSE/HYPOTHESIS The purpose of this study was to identify the factors associated with unfavorable radiological outcomes after OWHTO for varus knees. Our hypothesis was that there would be an optimal situation in which double-level osteotomy (DLO) has advantages over isolated OWHTO and an optimal cutoff value of structural parameters for which DLO should be considered in patients with severe varus knees. STUDY DESIGN Case-control study; Level of evidence, 3. METHODS The radiological and clinical outcomes of 337 patients who underwent OWHTO were retrospectively evaluated. A subgroup analysis was performed according to the weightbearing line ratio (WBLR) (group 1: <25th percentile; group 2: 25th-75th percentile; and group 3: >75th percentile) and factors associated with unfavorable radiological outcomes. For the assessment of cutoff values of the parameters favoring DLO, unfavorable radiological outcomes were categorized as follows: (1) medial proximal tibial angle (MPTA) >95°, (2) joint-line convergence angle (JLCA) >4° (insufficient medial release), (3) JLCA <0° (medial instability), (4) recurrence of a varus deformity, and (5) lateral hinge fracture. RESULTS The mean follow-up period was 66.2 ± 19.1 months. A low preoperative WBLR was related to a larger preoperative to postoperative change (Δ) in the WBLR, a larger reduction in coronal translation, a larger ΔMPTA, a wide preoperative lateral joint space, and a narrow preoperative medial joint space (P < .001, P < .001, P < .001, P = .016, and P = .003, respectively). However, only an MPTA >95° was significantly related to a low WBLR in the subgroup analysis according to unfavorable radiological outcomes (P = .038). The cutoff value of ΔWBLR causing an MPTA >95° was 46.5%, which showed a good area under the curve of 0.800, with a sensitivity of 74.4% and a specificity of 82.7%. The clinical outcomes significantly improved at the final follow-up compared with those preoperatively, with no significant differences between the WBLR groups. CONCLUSION A ΔWBLR ≥46.5% led to an MPTA >95°. However, clinical outcomes were not affected. DLO should be considered if the surgeon desires a postoperative MPTA ≤95°.
Collapse
Affiliation(s)
- Seung Jae Shim
- Department of Orthopedic Surgery, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, Republic of Korea
| | - Ho Won Jeong
- Department of Orthopedic Surgery, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, Republic of Korea
| | - Saeil Kim
- Department of Orthopedic Surgery, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, Republic of Korea
| | - Yong-Geun Park
- Department of Orthopedic Surgery, Jeju National University Hospital, Jeju National University College of Medicine, Jeju City, Republic of Korea
| | - Yong Seuk Lee
- Department of Orthopedic Surgery, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, Republic of Korea
| |
Collapse
|
10
|
Caubère A, Barbier O, Kley K, Hanak L, Jacquet C, Ollivier M. Double level osteotomy for genu varum: Is a return to sport possible? Orthop Traumatol Surg Res 2022; 109:103397. [PMID: 36087834 DOI: 10.1016/j.otsr.2022.103397] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Revised: 01/18/2022] [Accepted: 01/27/2022] [Indexed: 02/03/2023]
Abstract
INTRODUCTION A double level osteotomy (DLO) may be indicated in patients with genu varum when the deformity involves both the tibia and femur. These patients, who are often young and active, have a high functional demand and hope for a rapid return to sport. The purpose of our study was to assess return to sport and functional outcomes following DLO for symptomatic genu varum. MATERIALS AND METHODS A total of 40 patients (mean age 45.5±2 years) who underwent a DLO between 2018 and 2020, performed in 2 different hospitals, were reviewed after a minimum follow-up of 1-year. The mean initial varus was 11±2°. The type of sport and frequency of participation (UCLA activity score) as well as time to return to sport and level of activity recovered were defined as the primary endpoints. Functional scores were also assessed with the knee injury and osteoarthritis outcome score (KOOS). RESULTS At the last follow-up, 87.5% (n=35) of patients reported that they had returned to sport. The mean time to return to sport was 6±1 months with a significant difference (p<0.001) between the pre- and postoperative UCLA activity scores. There was a strong correlation between the presence of a joint line obliquity >3° and decreased functional outcomes (p<0.0001). The overall KOOS score improved (p<0.001) by a mean of 38.6 points after the correction. The 8 lateral cortical fractures (Takeuchi type I and II) and the 2 medial cortical fractures (Nakayama type 1) that were found had no impact on functional outcomes (p>0.05). CONCLUSION Our findings demonstrated that DLO provided rapid return to sport, thus making it possible to meet the functional demands and expectations of patients. LEVEL OF EVIDENCE IV; Retrospective study.
Collapse
Affiliation(s)
- Alexandre Caubère
- Service de Chirurgie Orthopédique et Traumatologie, Hôpital d'Instruction des Armées Sainte-Anne, 2, boulevard Sainte-Anne, BP 600, 83800 Toulon, France.
| | - Olivier Barbier
- Service de Chirurgie Orthopédique et Traumatologie, Hôpital d'Instruction des Armées Sainte-Anne, 2, boulevard Sainte-Anne, BP 600, 83800 Toulon, France
| | - Kristian Kley
- Harley Street Specialist Hospital, 18-22, Queen Anne Street, London, W1G8HU, United Kingdom
| | | | - Christophe Jacquet
- Service de Chirurgie Orthopédique et Traumatologie, Université Aix-Marseille, APHM, CNRS, ISM, Hôpital Sainte-Marguerite, Institut du Mouvement et de l'appareil Locomoteur, Marseille, France; Service de Chirurgie Orthopédique et Traumatologie, Hôpital Sainte-Marguerite, Institut du Mouvement et de l'appareil Locomoteur, 270, boulevard Sainte-Marguerite, BP 29, 13274 Marseille, France
| | - Matthieu Ollivier
- Service de Chirurgie Orthopédique et Traumatologie, Université Aix-Marseille, APHM, CNRS, ISM, Hôpital Sainte-Marguerite, Institut du Mouvement et de l'appareil Locomoteur, Marseille, France; Service de Chirurgie Orthopédique et Traumatologie, Hôpital Sainte-Marguerite, Institut du Mouvement et de l'appareil Locomoteur, 270, boulevard Sainte-Marguerite, BP 29, 13274 Marseille, France
| |
Collapse
|
11
|
Suh DW, Nha KW, Han SB, Cheong K, Kyung BS. Biplane Medial Opening-Wedge High Tibial Osteotomy Increases Posterior Tibial Slope more than Uniplane Osteotomy. J Knee Surg 2022; 35:1229-1235. [PMID: 33618401 DOI: 10.1055/s-0040-1722659] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Few clinical studies have compared uniplane high tibial osteotomy (HTO) with biplane HTO. The study aim was to compare the radiological and clinical results of uniplane HTO and biplane HTO, especially in terms of the increase in the posterior tibial slope (PTS). Medial opening-wedge HTO patients' medical records and radiological results from a single institution were retrospectively reviewed. Pre- and postoperative serial radiographs, including the Rosenberg, lateral view, and standing anteroposterior view of the whole lower extremity, magnetic resonance imaging at postoperative day 2, and the Western Ontario and McMaster Universities Arthritis Index (WOMAC) score at postoperative 2 years were reviewed to evaluate radiological and clinical results, including the change in PTS. A total of 61 knees, including 34 for uniplane and 27 for biplane HTOs, were enrolled. There were no significant differences in the pre- and postoperative mechanical angles or incidences of the lateral hinge fractures, and all patients showed complete union at postoperative 2 years. The PTS was increased more in the biplane group than in the uniplane group (3.1 ± 2.6 in biplane vs. 0.8 ± 1.7 in uniplane, p < 0.05). The WOMAC scores were 72 ± 9.3 in the uniplane and 75 ± 5.8 in the biplane group (not significant). The increase in PTS was lower in uniplane medial opening HTO than in biplane HTO.
Collapse
Affiliation(s)
- Dong Won Suh
- Department of Orthopedic Surgery, Barunsesang Hospital, Seongnam, Gyeonggi-do, Korea
| | - Kyung Wook Nha
- Department of Orthopaedic Surgery, Ilsanpaik Hospital, Inje University, Ilsan, Gyeonggi-do, Korea
| | - Seung Beom Han
- Department of Orthopedic Surgery, Korea University Anam Hospital, Korea University College of Medicine, Seoul, Korea
| | - Kuhoang Cheong
- Department of Orthopedic Surgery, Barunsesang Hospital, Seongnam, Gyeonggi-do, Korea
| | - Bong Soo Kyung
- Department of Orthopedic Surgery, Barunsesang Hospital, Seongnam, Gyeonggi-do, Korea
| |
Collapse
|
12
|
Jeong HW, Kim M, Choi HG, Park SY, Lee YS. Development of a machine learning model to predict lateral hinge fractures by analyzing patient factors before open wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 2022:10.1007/s00167-022-07137-6. [PMID: 36036269 DOI: 10.1007/s00167-022-07137-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/24/2022] [Accepted: 08/19/2022] [Indexed: 11/25/2022]
Abstract
PURPOSE Several methods have been developed to prevent lateral hinge fractures (LHFs), using only classic statistical models. Machine learning is under the spotlight because of its ability to analyze various weights and model nonlinear relationships. The purpose of this study was to create a machine learning model that predicts LHF with high predictive performance. METHODS Data were collected from a total of 439 knees with medial osteoarthritis (OA) treated with Medial open wedge high tibial osteotomy (MOW-HTO) from March 2014 to February 2020. The patient data included age, sex, height, and weight. Preoperative, determined, and modifiable factors were categorized using X-ray and CT data to create ensemble models with better predictive performance. Among the 57 ensemble models, which is the total number of possible combinations with six models, the model with the highest area under curve (AUC) or F1-score was selected as the final ensemble model. Gain feature importance analysis and the Shapley additive explanations (SHAP) feature explanation were performed on the best models. RESULTS The ensemble model with the highest AUC was a combination of a light gradient boosting machine (LGBM) and multilayer perceptron (MLP) (AUC = 0.992). The ensemble model with the highest F1-score was the model that combined logistic regression (LR) and MLP (F1-score = 0.765). Distance X was the most predictive feature in the results of both model interpretation analyses. CONCLUSION Two types of ensemble models, LGBM with MLP and LR with MLP, were developed as machine learning models to predict LHF with high predictive performance. Using these models, surgeons can identify important features to prevent LHF and establish strategies by adjusting modifiable factors. STUDY DESIGN Retrospective cohort study.
Collapse
Affiliation(s)
- Ho Won Jeong
- Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul National University Bundang Hospital, 166 Gumi-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, 463-707, South Korea
| | - Myeongju Kim
- Center for Artificial Intelligence in Healthcare, Seoul National University Bundang Hospital Healthcare Innovation Park, 166 Gumi-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, South Korea
| | - Han Gyeol Choi
- Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul National University Bundang Hospital, 166 Gumi-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, 463-707, South Korea
| | - Seong Yun Park
- Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul National University Bundang Hospital, 166 Gumi-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, 463-707, South Korea
| | - Yong Seuk Lee
- Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul National University Bundang Hospital, 166 Gumi-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, 463-707, South Korea.
| |
Collapse
|
13
|
Insufficient Correction and Preoperative Medial Tightness Increases the Risk of Varus Recurrence in Open-Wedge High Tibial Osteotomy. Arthroscopy 2022; 38:1547-1554. [PMID: 34601011 DOI: 10.1016/j.arthro.2021.09.028] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/13/2021] [Revised: 09/15/2021] [Accepted: 09/15/2021] [Indexed: 02/02/2023]
Abstract
PURPOSE To assess serial changes of limb alignment after open wedge high tibial osteotomy (HTO) using the weightbearing line (WBL) ratio in the midterm, with a focus on varus recurrence. METHODS Patients undergoing open wedge HTO from January 2010 to December 2016 were retrospectively reviewed. Those without serial postoperative weightbearing long-leg alignment films, those who showed remained varus alignment after osteotomy, and those who had <2 years of follow-up were excluded. In terms of immediate postoperative limb alignment (≤3 months) measured using WBL ratio, cases were categorized into 4 groups: <50%, undercorrection; 50% to 57%, insufficient correction; 57% to 67%, planned correction; and >67%, overcorrection. To determine risk factors for varus recurrence (WBL ratio <50%), immediate postoperative WBL ratio category and preoperative valgus and varus stress angles (which represent medial and lateral tightness of the joint, respectively) were investigated using logistic regression analysis, taking other related factors into account. Clinical outcomes according to varus recurrence were measured using Hospital for Special Surgery (HSS) scores. RESULTS A total of 148 cases were included. Varus recurrence was noted in 40 cases (27.0%), with a mean follow-up of 49.7 ± 21.8 months (range 24 to 102 months). The incidence of varus recurrence was different according to WBL ratio category: 10/10 (100.0%) in undercorrection; 16/33 (48.5%) in insufficient correction; 13/58 (22.4%) in planned correction; and 1/47 (2.1%) in overcorrection. Based on logistic regression analysis, insufficient correction and preoperative valgus stress angle were found to be significant risk factors (P = .038, and .008, respectively). With valgus stress angle <2°, 7 of 10 insufficient correction cases showed varus recurrence (P = .005). However, HSS scores did not differ according to varus recurrence (P = .363). CONCLUSION Insufficient correction and preoperative medial tightness increased the risk of varus recurrence. Especially in cases where preoperative valgus stress angle was <2°, insufficient correction was strongly associated with varus recurrence. However, no significant differences in clinical outcomes were observed according to varus recurrence in the midterm. LEVEL OF EVIDENCE III, retrospective cohort study.
Collapse
|
14
|
Morita Y, Kuriyama S, Maeda T, Nakamura S, Nishitani K, Ito H, Matsuda S. Hinge fractures reaching the tibial plateau can be caused by forcible opening of insufficient posterior osteotomy during open-wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 2022; 31:1533-1545. [PMID: 34981163 DOI: 10.1007/s00167-021-06816-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/10/2021] [Accepted: 11/20/2021] [Indexed: 11/27/2022]
Abstract
PURPOSE The purpose of this study was to use the finite element method (FEM) to reproduce fracture lines that reach the lateral tibial plateau during open-wedge high tibial osteotomy (OWHTO) in patients with Type III lateral hinge fracture (LHF). It was hypothesized that the FEM could clarify biomechanical causes of Type III LHF, enabling prevention of adverse complications. METHODS This study used the nonlinear FEM to analyze the data of eight knees in eight patients (two males and six females) with Type III LHF among 82 patients who underwent OWHTO, as well as the data of eight individuals with no LHF. To predict the onset of Type III LHF, simulation models were also developed in which posterior osteotomy sufficiency varied from 50% to perfect, the latter defined as osteotomy reaching the hinge point. RESULTS Real-life instances of Type III LHF caused by insufficient posterior osteotomy were reproduced in all patient-specific FEM models, and these models accurately predicted fracture types and locations. During opening of the osteotomy gap, the fracture line reached the lateral tibial plateau, and extended vertically from the end of the insufficient posterior osteotomy, avoiding the rigid proximal tibiofibular joint. In contrast, sufficient posterior osteotomy resulted in a lack of LHF. Posterior osteotomy extension ≥ 70% of the width of the osteotomy plane was the cut-off value to prevent Type III LHF. CONCLUSION Forced opening of insufficient posterior osteotomy was found to be a biomechanical cause of Type III LHF that extended perpendicularly to the lateral tibial plateau, avoiding the proximal tibiofibular joint. The clinical significance of this study is that sufficient posterior osteotomy during OWHTO, defined as at least 70% of the width of the osteotomy plane, can prevent Type III LHF.
Collapse
Affiliation(s)
- Yugo Morita
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Shinichi Kuriyama
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan.
| | - Takahiro Maeda
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Shinichiro Nakamura
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Kohei Nishitani
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Hiromu Ito
- Department of Orthopaedic Surgery, Kurashiki Central Hospital, Okayama, Japan
| | - Shuichi Matsuda
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan
| |
Collapse
|
15
|
Dislocated hinge fractures are associated with malunion after lateral closing wedge distal femoral osteotomy. Knee Surg Sports Traumatol Arthrosc 2022; 30:982-992. [PMID: 33638683 PMCID: PMC8901490 DOI: 10.1007/s00167-021-06466-2] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/02/2020] [Accepted: 01/19/2021] [Indexed: 10/26/2022]
Abstract
PURPOSE To evaluate the incidence, morphology, and associated complications of medial cortical hinge fractures after lateral closing wedge distal femoral osteotomy (LCW-DFO) for varus malalignment and to identify constitutional and technical factors predisposing for hinge fracture and consecutive complications. METHODS Seventy-nine consecutive patients with a mean age of 47 ± 12 years who underwent LCW-DFO for symptomatic varus malalignment at the authors' institution between 01/2007 and 03/2018 with a minimum of 2-year postoperative time interval were enrolled in this retrospective observational study. Demographic and surgical data were collected. Measurements evaluating the osteotomy cut (length, wedge height, hinge angle) and the location of the hinge (craniocaudal and mediolateral orientation, relation to the adductor tubercle) were conducted on postoperative anterior-posterior knee radiographs and the incidence and morphology of medial cortical hinge fractures was assessed. A risk factor analysis of constitutional and technical factors predisposing for the incidence of a medial cortical hinge fracture and consecutive complications was conducted. RESULTS The incidence of medial cortical hinge fractures was 48%. The most frequent morphological type was an extension fracture type (68%), followed by a proximal (21%) and distal fracture type (11%). An increased length of the osteotomy in mm (53.1 ± 10.9 vs. 57.7 ± 9.6; p = 0.049), an increased height of the excised wedge in mm (6.5 ± 1.9 vs. 7.9 ± 3; p = 0.040) as well as a hinge location in the medial sector of an established sector grid (p = 0.049) were shown to significantly predispose for the incidence of a medial cortical hinge fracture. The incidence of malunion after hinge fracture (14%) was significantly increased after mediolateral dislocation of the medial cortical bone > 2 mm (p < 0.05). CONCLUSION Medial cortical hinge fractures after LCW-DFO are a common finding. An increased risk of sustaining a hinge fracture has to be expected with increasing osteotomy wedge height and a hinge position close to the medial cortex. Furthermore, dislocation of a medial hinge fracture > 2 mm was associated with malunion and should, therefore, be avoided. LEVEL OF EVIDENCE Prognostic study; Level IV.
Collapse
|
16
|
Azoti W, Aghazade M, Ollivier M, Bahlouli N, Favreau H, Ehlinger M. Orientation and end zone of the osteotomy cut for high tibial osteotomy: Influence on the risk of lateral hinge fracture. A finite element analysis. Orthop Traumatol Surg Res 2021; 107:103031. [PMID: 34343697 DOI: 10.1016/j.otsr.2021.103031] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/08/2020] [Revised: 02/22/2021] [Accepted: 03/09/2021] [Indexed: 02/03/2023]
Abstract
INTRODUCTION the hinge plays a fundamental role in the support and consolidation of a high tibial osteotomy. The objective of this work was to analyse the influence of the end zone of the osteotomy cut and its orientation in relation to the articular joint line (JL) on the risk of hinge fracture. HYPOTHESIS a specific orientation and end zone of the osteotomy cut can be utilised to decrease the risk of hinge fracture. MATERIAL AND METHOD a finite element (FE) model was used to reproduce the proximal portion of the tibia and the proximal tibiofibular joint with transverse isotropic elastic bone properties. A 1.27mm thick, complete, anteroposterior saw cut was made with a U-shaped saw blade. Five proximal and lateral tibial zones were used according to Nakamura et al corresponding to the end zones of the osteotomy cut. Three angulations of the cut relative to the JL were defined: 10°, 15°, 20°. The tests consisted of simulating 15 possible situations (3 angulations for each of the 5 end zones) on this model. These simulations made it possible to identify the existence of a local stress concentration (von Mises, in MPa) at the level of the hinge, corresponding to the main judgment criterion. RESULTS If we consider only the end zones of the osteotomy cut, regardless of its angulation with respect to the JL, the zone which presents, on average, the lowest local stress concentration is the AM zone (40.3MPa). If we consider only the angulation of the osteotomy cut, with respect to the JL, regardless of the end zone of the cut, the angulation that locally concentrates, on average, the least stress is an angulation at 10° (147.7MPa). Finally, it is important to define the best end zone of the osteotomy cut for each angulation value in relation to the JL: for an angulation of 10°, the end zone must be in AM (38MPa), but also for an angulation of 15° (45MPa), and for an angulation of 20° (38MPa). DISCUSSION-CONCLUSION With the inherent caveats of the experimental conditions, the hypothesis is confirmed. An end zone of the osteotomy cut exists (AM) and an orientation (10°) that induces the lowest local stress concentration and therefore the least likely to induce lateral hinge fracture. However, the orientation of the osteotomy cut is also a matter of surgical habit, especially regarding complementary osteotomy of the tibial tuberosity that some may want to avoid. Thus, it is equally important to know the best end zone associated with a given angulation of the cut in relation to the JL, which according to these results is the AM zone for each angulation. This information helps guide the operator in their surgical practices according to their habits. LEVEL OF EVIDENCE V, expert opinion.
Collapse
Affiliation(s)
- Wiyao Azoti
- Laboratoire ICube, équipe MMB, 67400 Illkirch, France
| | | | - Matthieu Ollivier
- Département de chirurgie orthopédique, hôpital Sainte-Marguerite, hôpital Universitaire de Marseille, 270, boulevard Sainte-Marguerite, 13009 Marseille, France
| | | | - Henri Favreau
- Service de chirurgie orthopédique et de traumatologie, hôpital de Hautepierre, 1, avenue Molière, 67098 Strasbourg cedex, France
| | - Matthieu Ehlinger
- Laboratoire ICube, équipe MMB, 67400 Illkirch, France; Service de chirurgie orthopédique et de traumatologie, hôpital de Hautepierre, 1, avenue Molière, 67098 Strasbourg cedex, France.
| |
Collapse
|
17
|
Song JH, Bin SI, Kim JM, Lee BS. Unstable Lateral Hinge Fracture or Occult Complete Osteotomy Adversely Affects Correction Accuracy in Open-Wedge High Tibial Osteotomy. Arthroscopy 2021; 37:3297-3306. [PMID: 33940127 DOI: 10.1016/j.arthro.2021.04.032] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/19/2020] [Revised: 04/12/2021] [Accepted: 04/13/2021] [Indexed: 02/02/2023]
Abstract
PURPOSE To verify whether lateral hinge fracture (LHF) affects correction accuracy in open-wedge high tibial osteotomy (OWHTO) and to identify the fracture characteristics responsible for inaccurate correction, including LHF type and hinge location. METHODS Patients undergoing OWHTO with locking plate fixation between 2010 and 2016 were retrospectively reviewed. Patients who did not have a minimum 2-year of follow-up or postoperative long-standing hip-to-ankle radiographs were excluded. Correction accuracy was assessed using the weight-bearing line ratio: 57% to 67%, planned correction; 50% to 70%, acceptable correction; otherwise, inappropriate correction. The association between LHF and correction accuracy was assessed using the χ2 test. To identify the fracture characteristics responsible for inaccurate correction, LHF type (stable type 1 and unstable types 2 and 3) and hinge location (shallow osteotomy, deep osteotomy, and occult complete osteotomy) were analyzed using ordinal logistic regression analysis, taking other related demographic and radiologic factors into account. Clinical outcomes according to LHF type were evaluated using the Hospital for Special Surgery scores. RESULTS A total of 148 cases were included; 41 (27.7%) showed LHF: type 1, 32 cases; type 2, 7 cases; and type 3, 2 cases. Planned, acceptable, and inappropriate corrections were noted in 63 (42.6%), 36 (24.3%), and 48 (32.4%) cases, respectively. LHF had a significant association with correction accuracy (P = .010). Regarding fracture characteristics, unstable LHF and occult complete osteotomy were significant risk factors (P = .016 and P = .004, respectively). Specifically in cases of stable LHF, occult complete osteotomy adversely affected correction accuracy (P = .025). No difference was found in the final Hospital for Special Surgery scores according to LHF type (P = .816). CONCLUSIONS LHF affected the accuracy of coronal alignment correction in OWHTO. Unstable LHF or occult complete osteotomy were risk factors for inaccurate correction. Even among stable LHFs, those with occult complete osteotomy could lead to inaccurate correction. LEVEL OF EVIDENCE Level III, retrospective cohort study.
Collapse
Affiliation(s)
- Ju-Ho Song
- Department of Orthopedic Surgery, Chungnam National University Sejong Hospital, Chungnam National University School of Medicine, Daejeon, Korea
| | - Seong-Il Bin
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
| | - Jong-Min Kim
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Bum-Sik Lee
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| |
Collapse
|
18
|
Lee SJ, Kim JH, Baek E, Ryu HS, Han D, Choi W. Incidence and Factors Affecting the Occurrence of Lateral Hinge Fracture After Medial Opening-Wedge High Tibial Osteotomy. Orthop J Sports Med 2021; 9:23259671211035372. [PMID: 34646897 PMCID: PMC8504237 DOI: 10.1177/23259671211035372] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/05/2021] [Accepted: 05/04/2021] [Indexed: 11/16/2022] Open
Abstract
Background: Few clinical studies have reported the predictors of lateral hinge fracture (LHF) after medial opening-wedge high tibial osteotomy (MOWHTO). Purpose/Hypothesis: The purpose was to compare the incidence of LHF on plain radiographs versus computed tomography (CT) scans and to investigate the factors related to the development of LHF after MOWHTO. We hypothesized that (1) a higher LHF detection rate would be seen on CT scans versus plain radiographs and (2) LHF incidence would be related to opening gap width and hinge position. Study Design: Cohort study (diagnosis); Level of evidence, 3. Methods: A total of 97 MOWHTO cases were included. The presence and types of LHF were determined from plain radiographs and CT scans. Radiographic parameters were measured on plain radiographs taken 6 weeks postoperatively. Anterior and posterior opening gap widths, coronal and sagittal osteotomy slopes, and fibular height were calculated from CT scans. The wedge-hinge relationship and the zone of hinge position were assessed, and the patient and radiographic factors related to LHF occurrence were evaluated. Results: Seventeen LHF cases (20.5%) were detected on plain radiographs, while significantly more (37 cases; 44.6%) were found on CT scans (P = .001). Based on Takeuchi classification, 28 LHF cases were considered type 1, 7 were type 2, and 2 were type 3. Logistic regression analysis revealed that opening gap width (odds ratio, 1.615; 95% confidence interval, 1.232-2.118; P = .001) and posterior opening gap width (odds ratio, 3.731; 95% confidence interval, 1.642-4.351; P = .008,) differed significantly between patients with versus without LHF. Other patient and radiographic factors were not significantly related to LHF occurrence. Receiver operating characteristic curve analysis identified the opening gap width cutoff values for LHF as 11.0 mm (area under the curve, 0.81; sensitivity, 78.4%; specificity, 73.9%). Conclusion: The incidence of LHF after MOWHTO can be underestimated on plain radiographs compared with CT scans. Only large opening gap width, especially posterior gap width, was found to have a statistically significant relationship with occurrence of LHF. Therefore, special caution for possible LHF may be needed if a large correction is planned.
Collapse
Affiliation(s)
- Sang-June Lee
- Department of Orthopaedic Surgery, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea
| | - Jae-Hwa Kim
- Department of Orthopaedic Surgery, CHA Bundang Medical Center, CHA University School of Medicine, Seongnam, Republic of Korea
| | - Eugene Baek
- Department of Orthopaedic Surgery, CHA Bundang Medical Center, CHA University School of Medicine, Seongnam, Republic of Korea
| | - Han-Seung Ryu
- Department of Orthopaedic Surgery, CHA Bundang Medical Center, CHA University School of Medicine, Seongnam, Republic of Korea
| | - Donghun Han
- Department of Orthopaedic Surgery, CHA Bundang Medical Center, CHA University School of Medicine, Seongnam, Republic of Korea
| | - Wonchul Choi
- Department of Orthopaedic Surgery, CHA Bundang Medical Center, CHA University School of Medicine, Seongnam, Republic of Korea
| |
Collapse
|
19
|
Nakayama H, Kanto R, Onishi S, Kambara S, Amai K, Yoshiya S, Schröter S, Tachibana T, Iseki T. Hinge fracture in lateral closed-wedge distal femoral osteotomy in knees undergoing double-level osteotomy: assessment of postoperative change in rotational alignment using CT evaluation. Knee Surg Sports Traumatol Arthrosc 2021; 29:3337-3345. [PMID: 32748235 DOI: 10.1007/s00167-020-06197-w] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/29/2020] [Accepted: 07/27/2020] [Indexed: 01/17/2023]
Abstract
PURPOSE The purpose of this study was to examine the radiological features of hinge fracture occurring at the distal medial femoral cortex in knees undergoing biplanar lateral closed-wedge distal femoral osteotomy (LCW-DFO) in double-level osteotomy (DLO) based on pre- and postoperative CT image analyses. It was hypothesised that medial hinge fractures in LCW-DFO would occur with a similar incidence to that in high tibial osteotomy, and its occurrence would affect the clinical/radiological outcomes and induce unintended change in alignment depending on the fracture type (direction of the fracture). METHODS A consecutive series of 36 knees (31 patients) with primary varus osteoarthritis undergoing DLO comprised the study population. The mean age at surgery was 62.0 ± 5.9 years. Presence of hinge fracture was assessed on radiographs and CT images at 1 week. The fracture type was classified depending on the direction of the fracture line: crack propagation in line with the osteotomy (type 1) and fractures extending proximally (type 2) or distally (type 3) from the tip of the wedge. Computer-assisted assessments of bony limb alignment and bony geometry were conducted on a full-length weight-bearing radiograph and CT images using image analysis software. In addition, subjective clinical results were evaluated using the Knee Injury and Osteoarthritis Outcome Score (KOOS). Radiological and clinical follow-up results at 1 and 2 years were compared to the preoperative data, while comparative analysis was made between the subjects with and without a hinge fracture. RESULTS Postoperative image examinations revealed type 1 and 2 medial femoral hinge fractures in 4 and 7 knees, while no type 3 fracture was identified in the study population. Consequently, the overall incidence of the hinge fracture was 30.6% (11 of the 36 knees). Four of those 11 fractures (36.4%) could not be detected on plain radiographs. CT image analysis for three-dimensional bony geometry showed greater increase in internal rotation of the distal bony segment (increased femoral antetorsion by 9.5° on average) after surgery compared to the knees without a hinge fracture (P = 0.01). Clinical evaluation using the KOOS at 2 years showed no significant difference between the groups with and without hinge fractures. CONCLUSION In LCW-DFO, medial femoral hinge fractures occurred in 30.6% of the cases. Knees with type 1 hinge fracture exhibited significantly greater increase in femoral antetorsion as compared to those without hinge fracture. In this case series, postoperative weight-bearing protocol was delayed for knees with hinge fracture. Consequently, surgical results were not affected by the occurrence of hinge fracture for up to 2 years. LEVEL OF EVIDENCE IV (case series).
Collapse
Affiliation(s)
- Hiroshi Nakayama
- Department of Orthopaedic Surgery, Hyogo College of Medicine, 1-1 Mukogawa-cho, Nishinomiya, Hyogo, Japan.
| | - Ryo Kanto
- Department of Orthopaedic Surgery, Hyogo College of Medicine, 1-1 Mukogawa-cho, Nishinomiya, Hyogo, Japan
| | - Shintaro Onishi
- Department of Orthopaedic Surgery, Hyogo College of Medicine, 1-1 Mukogawa-cho, Nishinomiya, Hyogo, Japan
| | - Shunichiro Kambara
- Department of Orthopaedic Surgery, Nishinomiya Kaisei Hospital, 1-4 Ohama-cho, Nishinomiya, Hyogo, Japan
| | - Kenta Amai
- Department of Orthopaedic Surgery, Hyogo College of Medicine, 1-1 Mukogawa-cho, Nishinomiya, Hyogo, Japan
| | - Shinichi Yoshiya
- Department of Orthopaedic Surgery, Nishinomiya Kaisei Hospital, 1-4 Ohama-cho, Nishinomiya, Hyogo, Japan
| | - Steffen Schröter
- Diakonie Klinikum Jung-Stilling, Wichernstraße 40, 57074, Siegen, Germany
| | - Toshiya Tachibana
- Department of Orthopaedic Surgery, Hyogo College of Medicine, 1-1 Mukogawa-cho, Nishinomiya, Hyogo, Japan
| | - Tomoya Iseki
- Department of Orthopaedic Surgery, Hyogo College of Medicine, 1-1 Mukogawa-cho, Nishinomiya, Hyogo, Japan
| |
Collapse
|
20
|
Choi HG, Kim JS, Jung YS, Yoo HJ, Lee YS. Prediction and Development of Preventive Strategies for Lateral Hinge Fracture During Opening Wedge High Tibial Osteotomy Based on Osteotomy Configurations. Am J Sports Med 2021; 49:2942-2954. [PMID: 34328812 DOI: 10.1177/03635465211028985] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Lateral hinge fracture (LHF) is a major complication of opening wedge high tibial osteotomy (OWHTO) and may result in poor outcomes. PURPOSE/HYPOTHESIS The purpose of this study was to develop preventive strategies by identifying factors that affect LHFs. We hypothesized that (1) each LHF type would have different affecting factors and that (2) specific operative strategies that can contribute to the prevention of each LHF type can be developed. STUDY DESIGN Case-control study; Level of evidence, 3. METHODS We retrospectively analyzed 261 consecutive knees treated with biplanar OWHTO between March 2014 and December 2017. Perioperative radiological variables that can affect LHFs were measured and divided into 2 categories: unmodifiable and modifiable. A regression model was developed, and subgroup analyses involving comparisons between the non-LHF group and each LHF group were performed. The weightbearing line (WBL) ratio was measured at 2 weeks and 1 year after surgery to determine the serial changes in each LHF type. RESULTS A total of 66 knees (25.3%) were diagnosed with LHFs. From these, 26 (39.4%), 13 (19.7%), 15 (22.7%), and 12 (18.2%) showed type I, II, III, and I-variant LHFs, respectively. In the subgroup analysis, a larger posterior gap and distance X and a smaller fibular height (FH) were significant unmodifiable factors, while the retrotubercular thickness was a significant modifiable factor, for type I LHF. For type II LHF, a smaller lateral condylar slope and a larger distance X were significant unmodifiable factors, while the lateral distal fragment thickness and the osteotomy-condylar angle were significant modifiable factors. For type III LHF, a larger lateral condylar width and distance X and a smaller FH were significant unmodifiable factors, while the lateral proximal fragment thickness and the retrotubercular angle (RA) were significant modifiable factors. A smaller FH and a larger distance X were significant unmodifiable factors for type I-variant LHFs, while the lateral thickness ratio and the RA were significant modifiable factors. Between postoperative week 2 and 1 year, the WBL ratio decreased in cases with type I LHFs (P < .001) and increased in those with type II (P = .001) and type I-variant (P = .006) LHFs. CONCLUSION Unmodifiable and modifiable factors for the development of LHFs after OWHTO differ among LHF types. To prevent LHFs, the causes of each LHF must be identified, the patient's specific geometry be considered in the preoperative planning, and the surgical technique be modified according to the modifiable factors. In addition, during the rehabilitation period after OWHTO, specific caution and close observation are necessary for alignment changes related to each LHF type.
Collapse
Affiliation(s)
- Han Gyeol Choi
- Department of Orthopaedic Surgery, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seoul, Republic of Korea.,Department of Orthopaedic Surgery, Yonsei Sulgee Hospital, Seoul, Republic of Korea
| | - Joo Sung Kim
- Department of Orthopaedic Surgery, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seoul, Republic of Korea
| | - You Sun Jung
- Department of Orthopaedic Surgery, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seoul, Republic of Korea
| | - Hyun Jin Yoo
- Department of Orthopaedic Surgery, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seoul, Republic of Korea
| | - Yong Seuk Lee
- Department of Orthopaedic Surgery, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seoul, Republic of Korea
| |
Collapse
|
21
|
Kim JH, Lee DK, Park YB. Computed Tomography Detects Hinge Fractures After Medial Opening Wedge High Tibial Osteotomy: A Systematic Review. Arthroscopy 2021; 37:1337-1352. [PMID: 33242632 DOI: 10.1016/j.arthro.2020.11.031] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/02/2020] [Revised: 11/04/2020] [Accepted: 11/06/2020] [Indexed: 02/02/2023]
Abstract
PURPOSE To quantify the increased detection rate of lateral hinge fractures (LHFs) owing to additional computed tomography (CT), determine factors associated with LHFs, and compare radiologic and clinical outcomes of LHFs after medial opening wedge biplanar high tibial osteotomy (MOW-HTO). METHODS The MEDLINE, Embase, Cochrane Library, and Web of Science databases were systematically searched to identify studies reporting the incidence of LHFs detected using additional CT, showing radiologic factors, or comparing radiologic and clinical outcomes between LHFs and non-LHFs after MOW-HTO. Subgroup analyses were performed to compare stable and unstable LHFs. Two reviewers performed the study screening, risk-of-bias assessment, and data extraction processes. RESULTS Eleven studies were included in this review. The weighted estimate of the apparent incidence of LHFs in the pooled studies was 24.8%. The weighted estimate of the incidence was increased by 9.9% owing to the use of CT detection, which indicated that approximately 40% of total diagnosed LHFs were missed on plain radiographs or fluoroscopy. The pooled mean opening gap distance ranged from 11.40 to 12.60 mm in the LHF group and from 9.80 to 11.12 mm in the non-LHF group, and the mean difference in the opening gap distance was significantly larger in the LHF group (95% confidence interval, 0.64-1.84 mm; P < .0001). However, no significant differences in correction loss, bone union duration, and clinical outcomes were observed between the LHF and non-LHF groups. Subgroup analyses showed no significant differences between stable and unstable LHFs. CONCLUSIONS Postoperative CT evaluations increase the detection rate of LHFs compared with plain radiography alone. Furthermore, the opening gap distance was larger in the LHF group than in the non-LHF group, suggesting the need for attention when opening the wedge by more than 11.4 mm. However, the consequences of LHFs after MOW-HTO were not major concerns when proper management was provided. LEVEL OF EVIDENCE Level III, systematic review.
Collapse
Affiliation(s)
- Jun-Ho Kim
- Department of Orthopedic Surgery, Seoul Medical Center, Seoul, Republic of Korea
| | - Do Kyung Lee
- Department of Orthopaedic Surgery, Samsung Changwon Hospital, Sungkyunkwan University School of Medicine, Changwon, Republic of Korea
| | - Yong-Beom Park
- Department of Orthopedic Surgery, Chung-Ang University Hospital, Chung-Ang University, Seoul, Republic of Korea.
| |
Collapse
|
22
|
Chen P, Zhan Y, Zhan S, Li R, Luo C, Xie X. Biomechanical evaluation of different types of lateral hinge fractures in medial opening wedge high tibial osteotomy. Clin Biomech (Bristol, Avon) 2021; 83:105295. [PMID: 33662653 DOI: 10.1016/j.clinbiomech.2021.105295] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/19/2020] [Revised: 01/08/2021] [Accepted: 02/15/2021] [Indexed: 02/07/2023]
Abstract
BACKGROUND Lateral hinge fractures are common complications in the medial opening wedge high tibial osteotomy for treatment of knee osteoarthritis. The rehabilitation protocols are decided depending on the remaining stability following these fractures. This study aimed to evaluate the biomechanical properties of different types of lateral hinge fractures in medial opening wedge high tibial osteotomy. METHODS Twenty synthetic tibia models were used as test samples. A 10-mm bone wedge was removed from the medial side of the proximal tibias to create the bone defect. The samples were then divided into 4 groups: (1) intact lateral hinge; (2) Takeuchi type I fractures; (3) type II fractures; and (4) type III fractures. After fixation with a locking plate, the stability parameters including construct stiffness, wedge displacement, and construct strength were tested under compressive forces and compared among the 4 groups. FINDINGS No statistical difference was found in the construct stiffness among the 4 groups (P = 0.78). The type III fractures had the largest wedge displacement compared with the other 3 groups. The failure loads on average were significantly reduced in the type III fractures compared with those with intact hinge (P < 0.01) and in type I fractures (P = 0.04). No statistical difference was observed between the type I fractures and the intact hinge in terms of wedge displacement or failure loads. INTERPRETATION The type III fractures were the most unstable and patients with these fractures should be managed cautiously. Delayed weightbearing and/or additional fixation should be considered.
Collapse
Affiliation(s)
- Peng Chen
- Department of Orthopaedic Surgery, Zhejiang Sian International Hospital, 2369 Hongxing Road, Jiaxing, Zhejiang Province, 314000, China
| | - Yu Zhan
- Department of Orthopaedic Surgery, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, 600 Yishan Road, Shanghai 200233, China
| | - Shi Zhan
- Department of Orthopaedic Surgery, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, 600 Yishan Road, Shanghai 200233, China
| | - Ruiyang Li
- Department of Orthopaedic Surgery, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, 600 Yishan Road, Shanghai 200233, China
| | - Congfeng Luo
- Department of Orthopaedic Surgery, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, 600 Yishan Road, Shanghai 200233, China.
| | - Xuetao Xie
- Department of Orthopaedic Surgery, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, 600 Yishan Road, Shanghai 200233, China.
| |
Collapse
|
23
|
Itou J, Kuwashima U, Itoh M, Kuroda K, Yokoyama Y, Okazaki K. Monocortical fixation for locking plate distal screws does not impair mechanical properties in open-wedge high tibial osteotomy. BMC Musculoskelet Disord 2021; 22:157. [PMID: 33557809 PMCID: PMC7871549 DOI: 10.1186/s12891-021-03999-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/16/2020] [Accepted: 01/11/2021] [Indexed: 11/29/2022] Open
Abstract
Background The neurovascular bundle containing the deep peroneal nerve has a potential risk of injury during open-wedge high tibial osteotomy (OWHTO), particularly due to drilling for bicortical fixation at distal screw holes. Therefore, monocortical fixation is recommended for distal fixation of a long locking plate as long as good stability is ensured. The purpose of this study was to analyse the biomechanical properties of monocortical fixation of distal locking screws for OWHTO. Methods Three-dimensional models of bone and fixation materials simulating OWHTO were created using computed tomographic data of patients and material data of a T-shaped long locking plate and screws. Three of the four distal screws of the locking plate were chosen for a bicortical fixation or monocortical fixation procedure. In addition, loss of correction was assessed by measuring the medial proximal tibial angle (MPTA) in patients who underwent OWHTO with two bicortical and two monocortical distal fixation screws at 1 month and 1 year after surgery. Results No significant differences in stress were observed in either the normal or osteoporotic bone model between the monocortical and bicortical fixation models, including in the area of the lateral hinge at the osteotomy site. Furthermore, there were no significant differences in MPTA between the early post-operative period and 1-year follow-up. Conclusions The monocortical fixation method for three distal screws of the locking plate did not worsen the mechanical properties of fixation for OWHTO using a long locking plate with four proximal and four distal screws. In actual surgery, the number of distal bicortical screws should be reduced based on the patient’s condition, taking into account the risk of lateral hinge fracture and unexpected surgical complications. Using at least two bicortical screws would be practical considering the various factors related to reduced fixing ability.
Collapse
Affiliation(s)
- Junya Itou
- Department of Orthopaedic Surgery, Tokyo Women's Medical University, 8-1 Kawada-cho, Shinjuku-ku, Tokyo, 162-8666, Japan
| | - Umito Kuwashima
- Department of Orthopaedic Surgery, Tokyo Women's Medical University, 8-1 Kawada-cho, Shinjuku-ku, Tokyo, 162-8666, Japan
| | - Masafumi Itoh
- Department of Orthopaedic Surgery, Tokyo Women's Medical University, 8-1 Kawada-cho, Shinjuku-ku, Tokyo, 162-8666, Japan
| | - Koichi Kuroda
- Olympus Terumo Biomaterials Corp., Sasazuka NA Bldg., 1-50-1 Sasazuka, Shibuya-ku, Tokyo, 151-0073, Japan
| | - Yasuharu Yokoyama
- Olympus Terumo Biomaterials Corp., Sasazuka NA Bldg., 1-50-1 Sasazuka, Shibuya-ku, Tokyo, 151-0073, Japan
| | - Ken Okazaki
- Department of Orthopaedic Surgery, Tokyo Women's Medical University, 8-1 Kawada-cho, Shinjuku-ku, Tokyo, 162-8666, Japan.
| |
Collapse
|
24
|
Winkler PW, Rupp MC, Lutz PM, Geyer S, Forkel P, Imhoff AB, Feucht MJ. A hinge position distal to the adductor tubercle minimizes the risk of hinge fractures in lateral open wedge distal femoral osteotomy. Knee Surg Sports Traumatol Arthrosc 2021; 29:3382-3391. [PMID: 32833073 PMCID: PMC8458183 DOI: 10.1007/s00167-020-06244-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/29/2020] [Accepted: 08/14/2020] [Indexed: 11/29/2022]
Abstract
PURPOSE To evaluate the incidence and morphology of medial cortical hinge fractures in lateral open wedge distal femoral osteotomy (LOW-DFO) and to determine a safe zone for the position of the osteotomy hinge to minimize the risk of hinge fractures. METHODS Consecutive patients who underwent LOW-DFO for symptomatic valgus malalignment were screened for eligibility for this retrospective observational cohort study. Demographical and surgical data were collected. The incidence and morphology of medial cortical hinge fractures were evaluated on standard postoperative anterior-posterior knee radiographs. Comprehensive measurements evaluating the osteotomy gap and the position of the osteotomy hinge were taken. Additionally, each osteotomy hinge was assigned to a corresponding sector of a proposed five-sector grid of the distal medial femur. RESULTS A total of 100 patients (60% female) with a mean age of 31 ± 13 years were included. The overall incidence of medial cortical hinge fractures was 46% and three distinct fracture types were identified. The most frequently observed fracture type was extension of the osteotomy gap (76%), followed by a proximal (20%) and distal (4%) course of the fracture line in relation to the hinge. Group comparison (hinge fracture vs. no hinge fracture) showed statistically significant higher values for the height of the osteotomy gap (p = 0.001), the wedge angle (p = 0.036), and the vertical distance between the hinge and the proximal margin of the adductor tubercle (AT; p = 0.002) in the hinge fracture group. Furthermore, a significantly lower horizontal distance between the hinge and the medial cortical bone (p = 0.036) was observed in the hinge fracture group. A statistically significant higher incidence of medial cortical hinge fractures was observed when the position of the osteotomy hinge was proximal compared to distal to the proximal margin of the AT (53% vs. 27%; p = 0.023). CONCLUSION Medial cortical hinge fractures in LOW-DFO are a common finding with three distinct fracture types. To minimize the risk of medial cortical hinge fractures, it is recommended to aim for a position of the osteotomy hinge at the level of or distal to the proximal margin of the adductor tubercle. LEVEL OF EVIDENCE Prognostic study; Level III.
Collapse
Affiliation(s)
- Philipp W. Winkler
- Department for Orthopedic Sports Medicine, Klinikum Rechts Der Isar, Technical University of Munich, Ismaninger Str. 22, 81675 Munich, Germany
| | - Marco C. Rupp
- Department for Orthopedic Sports Medicine, Klinikum Rechts Der Isar, Technical University of Munich, Ismaninger Str. 22, 81675 Munich, Germany
| | - Patricia M. Lutz
- Department for Orthopedic Sports Medicine, Klinikum Rechts Der Isar, Technical University of Munich, Ismaninger Str. 22, 81675 Munich, Germany
| | - Stephanie Geyer
- Department for Orthopedic Sports Medicine, Klinikum Rechts Der Isar, Technical University of Munich, Ismaninger Str. 22, 81675 Munich, Germany
| | - Philipp Forkel
- Department for Orthopedic Sports Medicine, Klinikum Rechts Der Isar, Technical University of Munich, Ismaninger Str. 22, 81675 Munich, Germany
| | - Andreas B. Imhoff
- Department for Orthopedic Sports Medicine, Klinikum Rechts Der Isar, Technical University of Munich, Ismaninger Str. 22, 81675 Munich, Germany
| | - Matthias J. Feucht
- Department for Orthopedic Sports Medicine, Klinikum Rechts Der Isar, Technical University of Munich, Ismaninger Str. 22, 81675 Munich, Germany ,Department of Orthopedics and Trauma Surgery, Medical Center, Faculty of Medicine, Albert-Ludwigs-University of Freiburg, Freiburg, Germany
| |
Collapse
|
25
|
Hansen MI, Staghøj J, Khan N, Blønd L, Barfod KW. High tibial osteotomy performed with PEEK implant demonstrated a failure rate of 28. J ISAKOS 2020; 6:8-13. [PMID: 33833040 DOI: 10.1136/jisakos-2019-000394] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/29/2020] [Indexed: 11/03/2022]
Abstract
OBJECTIVES Opening-wedge high tibia osteotomies (HTO) can be technically challenging. The HTO iBalance system was designed to reduce vascular complications and to avoid secondary plate removal. The purpose of the study was to evaluate the performance of the HTO iBalance system in patients with symptomatic medial osteoarthritis and varus malalignment. METHODS The study was performed as a retrospective cohort study investigating a consecutive series of patients who underwent HTO with the iBalance system performed by a single surgeon from August 2013 to March 2016 at Zealand University Hospital, Koege, and Aleris-Hamlet Hospital. The primary outcome was the degree of realignment. The secondary outcome was Knee injury and Osteoarthritis Outcome Score (KOOS). Follow-up was performed at mean (SD) 25 (9.7) months. Weight-bearing long-leg standing radiographs were taken before surgery and at follow-up. Failure was defined as collapse of the HTO defined as a correction <50% of the intended correction at time of follow-up. Logistic regression was used to identify risk factors for failure. RESULTS 44 patients and a total of 47 knees were included in this study. Preoperatively the mechanical axis was a mean (SD) 5.8° (2.9) varus and postoperatively 2.3° (3.7) varus . The HTO failed in 13 of 47 knees (28%). Patients with failure showed no statistically significant differences to non-failure in any KOOS subscore (p>0.05). American Society of Anesthesiologists (ASA) score (p=0.01) and body mass index (BMI) (p=0.05) were correlated with failure, whereas bone transplantation and smoking were not. CONCLUSION In this study, the failure rate of HTO was 28%. High BMI and ASA-score were the only risk factors associated with failure while bone grafting and smoking were not. LEVEL OF EVIDENCE Retrospective cohort study, level III.
Collapse
Affiliation(s)
- Melek Inal Hansen
- Department of Orthopaedic Surgery, Zealand University Hospital Koge, Koge, Denmark
| | - Jeppe Staghøj
- Department of Orthopaedic Surgery, Zealand University Hospital Koge, Koge, Denmark
| | - Nissa Khan
- Department of Orthopaedic Surgery, Zealand University Hospital Koge, Koge, Denmark
| | - Lars Blønd
- Department of Orthopaedic Surgery, Zealand University Hospital Koge, Koge, Denmark.,Orthopedic Surgery, Aleris Hamlet Hospital Group, Soborg, Denmark
| | | |
Collapse
|
26
|
Gulagaci F, Jacquet C, Ehlinger M, Sharma A, Kley K, Wilson A, Parratte S, Ollivier M. A protective hinge wire, intersecting the osteotomy plane, can reduce the occurrence of perioperative hinge fractures in medial opening wedge osteotomy. Knee Surg Sports Traumatol Arthrosc 2020; 28:3173-3182. [PMID: 31773202 DOI: 10.1007/s00167-019-05806-7] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/07/2019] [Accepted: 11/12/2019] [Indexed: 12/15/2022]
Abstract
PURPOSE A recent study reported that positioning a K-wire to intersect the cutting plane at the theoretical lateral hinge location increases the lateral hinge's resistance to fracture during the opening of opening wedge high tibial osteotomy (OWHTO). The purpose of this study was to evaluate the clinical relevance of the use of this K-wire and its benefits in terms of lateral hinge protection during OWHTO in daily practice. METHODS A retrospective comparative study identified 206 patients who underwent OWHTO from January 2014 to December 2017. Among these patients, 71 had an additional K-wire (HK + group), whereas 135 did not (HK- group). The subjects meeting the inclusion criteria were included in a matched pairing process, which identified 60 patients in the HK + group and 60 patients in the HK- group. Mean follow-up time was 2.3 ± 1.0 years (range 2-4.2). Radiographic outcomes were evaluated with intraoperative and postoperative fluoroscopic imaging and with CT imaging at 6 weeks post OWHTO surgery. The knee osteoarthritis outcomes score (KOOS) was used and time needed to return to work and any kind of sports was collected. RESULTS Thirty six patients (30%) were found to have a LHF. Among these patients, 26 (72%) did not have an additional K-wire positioned at their theoretical lateral hinge location (HK- group) during the procedure. LHF rate for patients without additional K-wire group (HK-) was 43.3%, whereas it was 16.7% for the patients with an additional K-wire (HK +) [Odd ratio 3.8 95% CI 1.6-8.3; p = 0.005]. The mean time to return to work, return to any kind of sports, and bone union was significantly shorter for HK + group (p < 0.05). CONCLUSION This study demonstrated that during OWHTO, positioning a K-wire intersecting the cutting plane at the theoretical lateral hinge location reduced the number of intraoperative lateral hinge fractures. LEVEL OF EVIDENCE III retrospective case-control study.
Collapse
Affiliation(s)
- Firat Gulagaci
- Institute of Movement and Locomotion Department of Orthopedics and Traumatology, St Marguerite Hospital, 270 Boulevard Sainte Marguerite, BP 29, 13274, Marseille, France.,APHM, CNRS, ISM, Sainte-Marguerite Hospital, Institute for Locomotion, Department of Orthopedics and Traumatology, Aix Marseille University, Marseille, France.,The Institute for Locomotion, Aix-Marseille University, Marseille, France
| | - Christophe Jacquet
- Institute of Movement and Locomotion Department of Orthopedics and Traumatology, St Marguerite Hospital, 270 Boulevard Sainte Marguerite, BP 29, 13274, Marseille, France.,APHM, CNRS, ISM, Sainte-Marguerite Hospital, Institute for Locomotion, Department of Orthopedics and Traumatology, Aix Marseille University, Marseille, France.,The Institute for Locomotion, Aix-Marseille University, Marseille, France
| | - Matthieu Ehlinger
- Service de Chirurgie Orthopédique et de Traumatologie, CHU Hautepierre, Hôpital de Hautepierre, Hôpitaux Universitaires de Strasbourg, 1 Avenue Molière, 67098, Strasbourg Cedex, France
| | - Akash Sharma
- Institute of Movement and Locomotion Department of Orthopedics and Traumatology, St Marguerite Hospital, 270 Boulevard Sainte Marguerite, BP 29, 13274, Marseille, France.,APHM, CNRS, ISM, Sainte-Marguerite Hospital, Institute for Locomotion, Department of Orthopedics and Traumatology, Aix Marseille University, Marseille, France.,The Institute for Locomotion, Aix-Marseille University, Marseille, France
| | - Kristian Kley
- Institute of Movement and Locomotion Department of Orthopedics and Traumatology, St Marguerite Hospital, 270 Boulevard Sainte Marguerite, BP 29, 13274, Marseille, France.,APHM, CNRS, ISM, Sainte-Marguerite Hospital, Institute for Locomotion, Department of Orthopedics and Traumatology, Aix Marseille University, Marseille, France.,The Institute for Locomotion, Aix-Marseille University, Marseille, France
| | - Adrian Wilson
- The Wellington Hospital, Wellington Place, St. John's Wood, London, UK
| | - Sebastien Parratte
- Institute of Movement and Locomotion Department of Orthopedics and Traumatology, St Marguerite Hospital, 270 Boulevard Sainte Marguerite, BP 29, 13274, Marseille, France.,APHM, CNRS, ISM, Sainte-Marguerite Hospital, Institute for Locomotion, Department of Orthopedics and Traumatology, Aix Marseille University, Marseille, France.,The Institute for Locomotion, Aix-Marseille University, Marseille, France
| | - Matthieu Ollivier
- Institute of Movement and Locomotion Department of Orthopedics and Traumatology, St Marguerite Hospital, 270 Boulevard Sainte Marguerite, BP 29, 13274, Marseille, France. .,APHM, CNRS, ISM, Sainte-Marguerite Hospital, Institute for Locomotion, Department of Orthopedics and Traumatology, Aix Marseille University, Marseille, France. .,The Institute for Locomotion, Aix-Marseille University, Marseille, France.
| |
Collapse
|
27
|
Wu M, Wang Z, Zhou P, Zhang K, Chen X, Xiao Y, Guan J. [Early effectiveness analysis of lateral hinge fracture during medial opening-wedge high tibial osteotomy]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2020; 34:854-861. [PMID: 32666728 DOI: 10.7507/1002-1892.202001038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Objective To compare the clinical and radiologic effectiveness in patients with versus without lateral hinge fracture during medial opening-wedge high tibial osteotomy (MOWHTO) to evaluate the effect of lateral hinge fracture on short-term effectiveness. Methods The clinical data of 84 patients (97 knees) with medial compartment osteoarthritis who treated with MOWHTO between September 2015 and July 2018 was retrospectively analyzed. There were 10 males (10 knees) and 74 females (87 knees). The age ranged from 45 to 65 years with an average of 57.7 years. Lateral hinge fracture was recognized by the intraoperative fluoroscopy or immediate postoperative X-ray film. Fractures were classified into types Ⅰ, Ⅱ, and Ⅲ according to the Takeuchi classification. The healing of osteotomy was observed by radiographs during follow-up; the femur tibia angle (FTA), medialproximal tibial angle (MPTA), and hip-knee-ankle angle (HKA) were also calculated. The knee joint function was evaluated by Hospital for Special Surgery (HSS) score and knee society score (KSS). Results The incision healed by first intention. All patients were followed up 15-48 months with an average of 24.8 months. No hinge fracture occurred in 78 knees (80.41%, group A), and lateral hinge fractures were observed in 19 knees (19.59%, group B) and were divided into the type Ⅰ (13 knees, 13.40%) and type Ⅲ (6 knees, 6.19%) groups. Type Ⅰ fractures were not additionally treated, type Ⅲ fractures were anatomic reduced fixed with additional lag screws. X-ray film and CT examination showed that all patients had bone healing at 3 months after operation without delayed healing or nonunion. During follow-up, there was no loosening or fracture of internal fixation plates and screws. HKA, FTA, and MPTA of patients in group A and group B (type Ⅰ and Ⅲ) were significantly improved at each time point after operation compared with preoperative values ( P<0.05); there was no significant difference between groups at each time point before and after operation ( P>0.05). After operation, the pain of knee joint was alleviated and the function of joint was improved. At last follow-up, KSS score and HSS score of groups A and B were significantly improved compared with those before operation ( P<0.05), but there was no significant difference between the two groups ( P>0.05). Conclusion The lateral hinge fracture may occur during MOWHTO. As long as the treatment and rehabilitation were guided according to the fracture classification of the hinge, the effectiveness can be similar to those without the hinge fracture.
Collapse
Affiliation(s)
- Min Wu
- Department of Orthopaedics, the First Affiliated Hospital of Bengbu Medical College, Laboratory of Tissue and Transplant in Anhui Province, Bengbu Anhui, 233003, P.R.China
| | - Zhaodong Wang
- Department of Orthopaedics, the First Affiliated Hospital of Bengbu Medical College, Laboratory of Tissue and Transplant in Anhui Province, Bengbu Anhui, 233003, P.R.China
| | - Pinghui Zhou
- Department of Orthopaedics, the First Affiliated Hospital of Bengbu Medical College, Laboratory of Tissue and Transplant in Anhui Province, Bengbu Anhui, 233003, P.R.China
| | - Kuankuan Zhang
- Department of Orthopaedics, the First Affiliated Hospital of Bengbu Medical College, Laboratory of Tissue and Transplant in Anhui Province, Bengbu Anhui, 233003, P.R.China
| | - Xiaotian Chen
- Department of Orthopaedics, the First Affiliated Hospital of Bengbu Medical College, Laboratory of Tissue and Transplant in Anhui Province, Bengbu Anhui, 233003, P.R.China
| | - Yuzhou Xiao
- Department of Orthopaedics, the First Affiliated Hospital of Bengbu Medical College, Laboratory of Tissue and Transplant in Anhui Province, Bengbu Anhui, 233003, P.R.China
| | - Jianzhong Guan
- Department of Orthopaedics, the First Affiliated Hospital of Bengbu Medical College, Laboratory of Tissue and Transplant in Anhui Province, Bengbu Anhui, 233003, P.R.China
| |
Collapse
|
28
|
Comparative analysis of fixation configurations and their effect on outcome after medial open-wedge high tibial osteotomy. J Orthop Sci 2020; 25:627-634. [PMID: 31320145 DOI: 10.1016/j.jos.2019.06.018] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/31/2019] [Revised: 06/18/2019] [Accepted: 06/27/2019] [Indexed: 11/22/2022]
Abstract
PURPOSE The purposes of this study were to analyze and compare 1) the postoperative fixation configurations, and 2) radiological and clinical outcomes between the new conceptual fixation device (LCfit) and the conventional locking plates. METHODS Retrospective comparative analysis of 304 cases who underwent open-wedge high tibial osteotomy with four different locking plate systems including the LCfit system was conducted. In analyzing the fixation configuration of each locking plate system, the plate position, the gap between plate and bone, screw angle, and screw length were evaluated from postoperative CT scans. The clinical outcomes and radiological parameters of four patient groups corresponding to the four locking plate systems were also compared. RESULTS In the analysis of the fixation configurations, the LCfit system showed more posteromedial plate position, decreased gap between plate and bone, reduced screw angle, and longer screw length compared to the other three locking plates. However, there were no significant differences in clinical outcomes and radiological parameters such as hip-knee-ankle angle, weight-bearing line position, medial proximal tibial angle, and posterior slope between the four groups. CONCLUSION The newly designed fixation system (LCfit) for open-wedge high tibial osteotomy showed fixation configurations that have theoretical mechanical advantages over conventional anatomical locking plates. However, there were no significant differences in clinical outcomes and radiological parameters between LCfit and the other locking plate systems. LEVEL OF EVIDENCE Level III, retrospective cohort study.
Collapse
|
29
|
Uniplane medial opening wedge high tibial osteotomy relative to a biplane osteotomy can reduce the incidence of lateral-hinge fracture. Knee Surg Sports Traumatol Arthrosc 2020; 28:1436-1444. [PMID: 31069445 DOI: 10.1007/s00167-019-05522-2] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/20/2018] [Accepted: 04/29/2019] [Indexed: 02/06/2023]
Abstract
PURPOSE With surgical modifications reflecting plate design differences of the specific rigid locking plate adding a metal wedge, uniplane high tibial osteotomy (HTO) has fewer lateral-hinge fractures and fewer plate irritations than biplane HTO. METHODS Uniplane HTO with a rigid locking plate adding a metal wedge was compared with biplane HTO with a rigid locking plate including a proximal D-hole. For comparison, the HTO patients' medical records and radiological results in a single institution were retrospectively reviewed. The Oxford knee score 2 years post-operation, CT scan at post-operative day 2 and serial standing long-bone scanography were reviewed to evaluate clinical outcome and radiological results, including the incidence of lateral-hinge fracture, plate irritation and correction loss to varus alignment. RESULTS A total of 103 knees, including 59 uniplane HTO and 44 biplane HTO, were enrolled. The Oxford scores were 38.1 ± 7.8 in the uniplane group and 35.9 ± 8.3 in the biplane group (ns). On CT scans, more lateral-hinge fractures developed in the biplane group, and seven knees (12%) of the uniplane group and 12 knees (27%) of the biplane group had Takeuchi type I stable hinge fracture (p < 0.05); unstable fracture was not noted in either group. Plate irritation occurred in nine knees (19%) of the uniplane group and in 14 knees (32%) of the biplane group, and the difference was statistically significant (p < 0.05). CONCLUSION In clinical situations including the use of surgical modifications reflecting plate design differences, fewer lateral-hinge fractures developed after uniplane medial opening-wedge HTO compared with biplane HTO. Uniplane HTO potentially represents a better option than biplane HTO for the prevention of lateral-hinge fracture. LEVEL OF EVIDENCE IV.
Collapse
|
30
|
Adding a protective K-wire during opening high tibial osteotomy increases lateral hinge resistance to fracture. Knee Surg Sports Traumatol Arthrosc 2020; 28:751-758. [PMID: 30783689 DOI: 10.1007/s00167-019-05404-7] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/30/2018] [Accepted: 02/06/2019] [Indexed: 12/14/2022]
Abstract
PURPOSE It was hypothesized in this in-vitro study that positioning a K-wire intersecting the cutting plane at the theoretical lateral hinge location would limit the cut depth and help preserve the lateral hinge during the opening of the osteotomy. Objectives were (1) to compare the mechanical resistance of the hinge and the protective effect of leaving the K-wire during the opening procedure (2) to check if the K-wire would limit the depth of the osteotomy. METHODS An ex-vivo mechanical study, testing 5 pairs of fresh-frozen tibias, was designed. CT-scan based Patient-specific cutting guides were obtained to define the cutting plane and the location of the K-wire at the hinge, using standardized 3D planning protocol. In each pair, OWHTO was performed either with or without the K-wire. To evaluate the hinge's resistance to fracture, the specimens were rigidly fixed at the proximal tibia and a direct load was applied on the free tibial diaphysis to open the osteotomy. The maximum load at breakage, maximum permissible displacement and maximal angulation of the osteotomy before hinge failure was measured. To assess the preservation of an unscathed hinge (protected by the K-wire), the distance from the end of the osteotomy cut to the lateral tibial cortical was measured in mm. RESULTS The maximum load to hinge breakage in the K-wires PsCG knees compared to the control group (48.3 N vs 5.5 N, p = 0.004), the maximum permissible displacement (19.8 mm vs 7.5 mm, p = 0.005) and the maximal angulation of the osteotomy before hinge breakage (9.9° vs 2.9°, p = 0.002) were all statistically superior in the K-wires PsCG knees compared to the control group. A mean distance of 10 ± 1 mm between cut-bone (saw-print) and lateral hinge cortical bone was found post-performing the osteotomy and the hinge failing. CONCLUSION The maximum load to breakage and the maximum permissible displacement were, respectively, 880% and 260% higher during the opening of the OWHTO in using K-wires compared to the non-K-wire control group. This confirms the mechanical advantage of using a K-wire for both stabilization and protecting the Hinge during OWHTO. This comparative cadaveric study shows an improvement of the lateral hinges resistance to failing during the opening of the osteotomy. This can be achieved by the placement of a K-wire intersecting the cutting plane at the theoretical location of the lateral hinge.
Collapse
|
31
|
Ehlinger M, Ollivier M, Course S, Guerin A, Lantz É, Zahraa D, Bonnomet F, Bahlouli N. Effect of saw blade geometry on crack initiation and propagation on the lateral cortical hinge for HTO: Finite element analysis. Orthop Traumatol Surg Res 2019; 105:1079-1083. [PMID: 31447398 DOI: 10.1016/j.otsr.2019.04.026] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/12/2018] [Revised: 01/23/2019] [Accepted: 04/16/2019] [Indexed: 02/02/2023]
Abstract
INTRODUCTION The hinge plays a primary role in the hold and healing of a high tibial osteotomy (HTO). Weakening of the hinge is a risk factor for failure. The aim of our study was to determine whether the geometry of the saw blade's cutting edge impacts crack initiation or propagation on the hinge. HYPOTHESIS A certain cutting edge geometry exists that will reduce this risk. MATERIALS AND METHODS A finite element model with transverse isotropic elastic bone properties was created. A 1.27-mm thick saw cut (full thickness in anteroposterior direction) was made leaving a 1cm lateral cortical hinge. Three different cutting edge geometries were compared: rectangular, U-shaped, V-shaped. Opening of the osteotomy was done over 1mm for 1 s by a load applied distally with the proximal portion fixed. In the first simulation, no crack was initiated at the hinge, while in the second simulation, the beginnings of a 2mm crack angled upward at 15° was added. These two simulations were used to identify whether a local stress riser was present at the hinge. This information was used to calculate the energy release rate to the hinge, which corresponds to the energy needed to initiate and propagate a crack on the hinge. RESULTS In the first simulation (no crack initiation), a rectangular saw blade geometry resulted in the lowest local stress concentration. In the second simulation (with crack initiation), the U-shaped geometry resulted in the lowest local stress concentration. The U-shaped geometry had the lowest energy release rate, meaning that it was the least likely to initiate and propagate a crack on the lateral cortical hinge. DISCUSSION/CONCLUSION Keeping the inherent limitations related to computer modelling in mind, our findings show that a U-shaped cutting edge is least likely to initiate or propagate a crack since it has the lowest energy release rate. This confirms our hypothesis. LEVEL OF EVIDENCE V, expert opinion.
Collapse
Affiliation(s)
- Matthieu Ehlinger
- Service de chirurgie orthopédique et de traumatologie, hôpital de Hautepierre, CHU de Strasbourg, 1, avenue Molière, 67098 Strasbourg, France; Laboratoire ICube, équipe MMB, 67400 Illkirch, France.
| | - Matthieu Ollivier
- Département de chirurgie orthopédique, hôpital Sainte-Marguerite, hôpital universitaire de Marseille, 270, boulevard Sainte-Marguerite, 13009 Marseille, France
| | | | - Arnaud Guerin
- Laboratoire ICube, équipe MMB, 67400 Illkirch, France
| | - Éric Lantz
- Laboratoire ICube, équipe MMB, 67400 Illkirch, France
| | - Dany Zahraa
- Laboratoire ICube, équipe MMB, 67400 Illkirch, France
| | - François Bonnomet
- Service de chirurgie orthopédique et de traumatologie, hôpital de Hautepierre, CHU de Strasbourg, 1, avenue Molière, 67098 Strasbourg, France
| | | |
Collapse
|
32
|
Dorofeev A, Tylla A, Benco M, Drescher W, Stangl R. Opposite hinge fractures in high tibial osteotomy: a displacement subtype is more critical than a fracture type. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2019; 30:297-305. [PMID: 31506790 DOI: 10.1007/s00590-019-02549-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2019] [Accepted: 09/06/2019] [Indexed: 11/30/2022]
Abstract
PURPOSE Analysis of the structure of the fractures of opposite hinge (FOH) after angle-stable closed-wedge (CW) and open-wedge (OW) high tibial osteotomy (HTO), and their influence on the development of tibial pseudarthrosis. METHODS 187 CW and 94 OWHTOs were analyzed retrospectively. The FOHs in the OWHTO were classified according to Takeuchi, and in the CWHTO-according to the own classification with two types (depending on the direction of FOH). FOHs in both techniques were also subdivided into three subtypes according to displacement (A-non-displaced, B-primarily displaced, C-secondarily displaced). The statistical analysis included correlation analysis and logistic regression. RESULTS FOHs were found in 81 (43.3%) CW and 39 (41.2%) OWHTOs. The stable type 1 fractures predominated in OWHTO (76.9 vs. 42%, p < 0.001), the unstable type 2 FOHs prevailed in CWHTO (58 vs. 17.9%, p < 0.001). The tibial pseudarthrosis rate was higher with type 1 (20 vs. 12.9%, n.s.) and subtype A (16.7 vs. 6.8%, p = 0.048) FOHs in OWHTO, and with type 2 (20 vs. 0%, p < 0.001) and subtypes B (25 vs. 0%, p < 0.001) and C (29.4 vs. 25%, n.s.) in CWHTO (without FOHs 0.9% in CW and 1.8% in OWHTO, n.s.). Relevant correlations were detected between the pseudarthrosis rate and fracture type only in CWHTO (ρs = 0.298, p < 0.001, OR 24.87 for type 2) and displacement subtype in both groups (for subtype C: ρs = 0.345, p < 0.001, OR 43.75 and ρs = 0.231, p = 0.02, OR 18.0, respectively). CONCLUSIONS The unstable FOH types were more common in CWHTO. The displacement subtype was more predictive for the development of tibial pseudarthrosis than the fracture type, especially in OWHTO. The secondarily displaced FOHs (subtype C) represented the highest risk for the occurrence of pseudarthrosis in both techniques.
Collapse
Affiliation(s)
- Anton Dorofeev
- Department of Orthopaedic Surgery, Sana Klinikum Rummelsberg, Rummelsberg 71, 90592, Schwarzenbruck, Germany.
| | - Alfred Tylla
- Department of Orthopaedic Surgery, Sana Klinikum Rummelsberg, Rummelsberg 71, 90592, Schwarzenbruck, Germany
| | - Martin Benco
- Department of Orthopaedic Surgery, Sana Klinikum Rummelsberg, Rummelsberg 71, 90592, Schwarzenbruck, Germany
| | - Wolf Drescher
- Department of Orthopaedic Surgery, Sana Klinikum Rummelsberg, Rummelsberg 71, 90592, Schwarzenbruck, Germany.,Department of Orthopaedics, RWTH University Hospital, Aachen, Germany
| | - Richard Stangl
- Department of Orthopaedic Surgery, Sana Klinikum Rummelsberg, Rummelsberg 71, 90592, Schwarzenbruck, Germany
| |
Collapse
|
33
|
Lösungen für häufige Komplikationen bei Beinachsenkorrekturen. ARTHROSKOPIE 2019. [DOI: 10.1007/s00142-019-00305-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
34
|
Affiliation(s)
- Joseph N Liu
- Department of Orthopedic Surgery, Loma Linda Medical Center, 11234 Anderson Street, Loma Linda, CA, USA
| | - Avinesh Agarwalla
- Department of Orthopaedic Surgery, Westchester Medical Center, 100 Woods Road, Valhalla, NY 10595, USA
| | - Andreas H Gomoll
- Division of Sports Medicine, Department of Orthopedic Surgery, Hospital for Special Surgery, 535 East 70th Street, New York, NY 10021, USA.
| |
Collapse
|
35
|
Han SB, Choi JH, Mahajan A, Shin YS. Incidence and Predictors of Lateral Hinge Fractures Following Medial Opening-Wedge High Tibial Osteotomy Using Locking Plate System: Better Performance of Computed Tomography Scans. J Arthroplasty 2019; 34:846-851. [PMID: 30733072 DOI: 10.1016/j.arth.2019.01.026] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/21/2018] [Revised: 12/25/2018] [Accepted: 01/11/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND This study compared the rates of plain radiographs and computed tomography (CT) for detecting lateral hinge fractures and to evaluate factors affecting lateral hinge fractures in patients following medial opening-wedge high tibial osteotomy (MOWHTO). METHODS This prospective study included 59 patients (65 knees) undergoing MOWHTO for primary medial compartment osteoarthritis with a 2-year follow-up between 2013 and 2016. Clinical and radiographic evaluations were performed using Knee Society Score and Western Ontario and McMaster Universities Arthritis Index, and we calculated the hip-knee-ankle angle, weight-bearing line ratio, lateral distal femoral angle, medial proximal tibial angle, posterior tibial slope, osteotomy gap height, and osteotomy gap filling rate. Immediate plain radiographs and CT were used to detect lateral hinge fractures according to Takeuchi's method. RESULTS Among 65 knees, the incidence of lateral hinge fractures was 13.8% (Type I: 7, Type II: 2). Only 6 knee fractures (9.2%) were detected on postoperative plain radiographs, including 5 Type I fractures and 1 Type II fracture. An additional 3 knees (4.6%) were detected on postoperative CT scans, including 2 Type I fractures and 1 Type II fracture. Furthermore, osteotomy gap height (adjusted odds ratio = 1.831, P = .016) was the only predictor of lateral hinge fractures. CONCLUSION The incidence of lateral hinge fractures after MOWHTO was 13.8%. CT (13.8%) afforded higher detection rates for lateral hinge fractures than did plain radiographs (9.2%) despite a marginal difference with uncertain significance. Osteotomy gap height was the only predictor of lateral hinge fractures. LEVEL OF EVIDENCE Prospective cohort study (Level II).
Collapse
Affiliation(s)
- Seung-Beom Han
- Department of Orthopedic Surgery, Korea University Anam Hospital, Korea University College of Medicine, Seoul, Republic of Korea
| | - Jae-Hyuk Choi
- Department of Orthopedic Surgery, Korea University Anam Hospital, Korea University College of Medicine, Seoul, Republic of Korea
| | - Atul Mahajan
- Department of Orthopedic Surgery, Korea University Anam Hospital, Korea University College of Medicine, Seoul, Republic of Korea
| | - Young-Soo Shin
- Department of Orthopedic Surgery, Chuncheon Sacred Heart hospital, Hallym University School of Medicine, Chuncheon, Republic of Korea
| |
Collapse
|
36
|
Posterior cortical breakage leads to posterior tibial slope change in lateral hinge fracture following opening wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 2019; 27:698-706. [PMID: 29785447 DOI: 10.1007/s00167-018-4977-4] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/20/2017] [Accepted: 05/03/2018] [Indexed: 10/16/2022]
Abstract
PURPOSE This study was designed to analyze the relationship between changes in posterior tibial slope and the absence or presence of lateral hinge fracture, diagnosed in the sagittal and axial planes, as well as the coronal plane, by computed tomography (CT) following opening wedge high tibial osteotomy (HTO). METHODS This study involved 55 patients (55 knees) undergoing opening wedge HTO for primary medial osteoarthritis. Lateral hinge fractures were evaluated on CT scans according to the Takeuchi classification and were also classified as subtypes A, B, and C, depending on anterior, posterior, and both anterior and posterior cortical disruptions, respectively, as determined by the sagittal and axial planes of CT scans which corresponded to the fracture line visible on coronal CT scans. RESULTS Of the 55 knees, 23 were found on postoperative CT scans to have lateral hinge fractures. All 23 were classified as Type I, with 11, 12, and 0 being subtypes A, B, and C, respectively. Mean change in posterior tibial slope from 3 weeks postoperatively to last follow up in subtype B was significantly greater than in subtype A (2.5° vs 0.2°, P = 0.008) and in knees without hinge fracture (2.5° vs 0.1°, P = 0.002). CONCLUSION Type I lateral hinge fractures encroached either the anterior or posterior cortex of the proximal tibia, but not both. In addition, posterior tibial slope increased over time following surgery in knees with Type I lateral hinge fracture and posterior cortex breakage, suggesting that caution should be exercised when deciding the starting time for weight bearing in such patients. LEVEL OF EVIDENCE Case series, Level IV.
Collapse
|
37
|
Carranza VA, Reeves J, Getgood A, Burkhart TA. Development and validation of a finite element model to simulate the opening of a medial opening wedge high tibial osteotomy. Comput Methods Biomech Biomed Engin 2019; 22:442-449. [PMID: 30714405 DOI: 10.1080/10255842.2018.1563599] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Medial opening wedge high tibial osteotomy (MOWHTO) is a surgical procedure intended to alter the coronal and sagittal plane alignment of the lower limb to primarily relieve the symptoms of osteoarthritis in the medial compartment of the knee. The purpose of this work was to develop and validate a finite element model to simulate the opening of a high tibial osteotomy and determine whether a pilot hole at the cortical hinge reduces the risk of lateral cortical fracture. Fifteen models were reconstructed from CT images of eight cadaveric specimens. The validated models indicated that the addition of the pilot hole increased the stresses and likelihood of a type-I and type-II fractures during the opening of a medial open wedge high tibial osteotomy compared to the no-hole condition.
Collapse
Affiliation(s)
- Victor A Carranza
- a School of Biomedical Engineering , Western University , London , ON , Canada
| | - Jacob Reeves
- b Mechanical and Materials Engineering , Western University , London , ON , Canada
| | - Alan Getgood
- c Fowler Kennedy Sport Medicine Clinic, Department of Surgery , Western University , London , ON , Canada
| | - Timothy A Burkhart
- d Lawson Health Research Institute, Department of Mechanical and Materials Engineering , Western University , London , ON , Canada
| |
Collapse
|
38
|
Biomechanical investigation of the type and configuration of screws used in high tibial osteotomy with titanium locking plate and screw fixation. J Orthop Surg Res 2019; 14:35. [PMID: 30691494 PMCID: PMC6348642 DOI: 10.1186/s13018-019-1062-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/23/2018] [Accepted: 01/03/2019] [Indexed: 01/01/2023] Open
Abstract
Background To maintain the corrected alignment after high tibial osteotomy (HTO), fixation with titanium locking plate and screws is widely used in current practice; however, screw breakage is a common complication. Thus, this study was to investigate the mechanical stability of HTO with locking plate and various screw fixations, including the length as well as the type. Methods A finite element (FE) model involving a distal femur, meniscus, and a proximal tibia with HTO fixed with a titanium locking plate and screws was created. The angle of the medial open wedge was 12°, and bone graft was not used. Two types of screws, namely conventional locking and far-cortical locking screws, with various lengths and configurations were used. At the proximal tibia, conventional locking screws with different lengths, 30 and 55 mm, were used; at the tibia shaft, different screw fixations including one-cortical, two-cortical, and far-cortical locking screws were used. Results The use of far-cortical locking screw generated the highest equivalent stress on the screws, which was four times (from 137.3 to 541 MPa) higher than that of the one-cortical screw. Also, it led to the maximum deformation of the tibia and a greater gap deformation at the osteotomy site, which was twice (from 0.222 to 0.442 mm) larger than that of the one-cortical screw. The effect of different locking screw length on tibia deformation and implant stress was minor. Conclusion Thus, far-cortical locking screws and plates increase interfragmentary movement but the screw stress is relatively high. Increasing the protection time (partial weight duration) is suggested to decrease the risk of screw breakage in HTO through fixation with titanium far-cortical locking screws and plates.
Collapse
|
39
|
Kim KI, Kim GB, Kim HJ, Lee SH, Yoon WK. Extra-articular Lateral Hinge Fracture Does Not Affect the Outcomes in Medial Open-Wedge High Tibial Osteotomy Using a Locked Plate System. Arthroscopy 2018; 34:3246-3255. [PMID: 30396798 DOI: 10.1016/j.arthro.2018.07.022] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/06/2018] [Revised: 07/05/2018] [Accepted: 07/09/2018] [Indexed: 02/02/2023]
Abstract
PURPOSE To compare the radiologic and clinical outcomes in patients with and without lateral hinge fractures (LHFs) during medial open-wedge high tibial osteotomy (MOWHTO) using a locked plate system, as well as to assess whether LHFs could affect the midterm outcomes. METHODS From May 2008 to November 2015, 164 knees underwent MOWHTO using a locked plate system for the treatment of knee osteoarthritis. LHFs were recognized by radiographs during or after the high tibial osteotomy and were not additionally treated. In all patients, we applied the same rehabilitation protocol that allowed full weight bearing at 6 weeks. Patients were divided into LHF (types I and II) and nonfracture groups. Radiologically, we compared any serial changes in the hip-knee-ankle angle, femorotibial angle, medial proximal tibial angle, and posterior tibial slope angle from the immediate postoperative radiographs to the final radiographs. The union process of the osteotomy site among the groups was also evaluated. Clinically, the postoperative American Knee Society Score and knee range of motion at latest follow-up were compared. Postoperative complications were also evaluated. RESULTS The average age at operation was 56.0 years (range, 42-67 years), and the average follow-up period was 62.2 months (range, 24-120 months). LHFs were observed in 37 knees (22.6%) and were divided into the type I (16 knees) and type II (21 knees) groups. All groups showed no significant changes in serial evaluations of the postoperative hip-knee-ankle angle, femorotibial angle, medial proximal tibial angle, and posterior tibial slope angle. The improvements in the American Knee Society Score and knee range of motion were not significantly different among the groups. No patients showed correction loss or union problems. CONCLUSIONS Type I and II LHFs in MOWHTO using a medial locked plate system and relatively conservative rehabilitation protocol with full weight-bearing walking commenced at 6 weeks postoperatively showed no radiologic changes or functional deterioration during midterm follow-up. LEVEL OF EVIDENCE Level IV, case series.
Collapse
Affiliation(s)
- Kang-Il Kim
- Department of Orthopedic Surgery, Kyung Hee University Hospital at Gangdong, Seoul, Republic of Korea; Department of Orthopaedic Surgery, College of Medicine, Kyung Hee University, Seoul, Republic of Korea
| | - Gi Beom Kim
- Department of Orthopedic Surgery, Kyung Hee University Hospital at Gangdong, Seoul, Republic of Korea; Department of Orthopaedic Surgery, College of Medicine, Kyung Hee University, Seoul, Republic of Korea.
| | - Hwan Jin Kim
- Department of Orthopedic Surgery, Kyung Hee University Hospital at Gangdong, Seoul, Republic of Korea; Department of Orthopaedic Surgery, College of Medicine, Kyung Hee University, Seoul, Republic of Korea
| | - Sang Hak Lee
- Department of Orthopedic Surgery, Kyung Hee University Hospital at Gangdong, Seoul, Republic of Korea; Department of Orthopaedic Surgery, College of Medicine, Kyung Hee University, Seoul, Republic of Korea
| | - Wan-Keun Yoon
- Department of Orthopedic Surgery, Kyung Hee University Hospital at Gangdong, Seoul, Republic of Korea; Department of Orthopaedic Surgery, College of Medicine, Kyung Hee University, Seoul, Republic of Korea
| |
Collapse
|
40
|
Lee SS, Celik H, Lee DH. Predictive Factors for and Detection of Lateral Hinge Fractures Following Open Wedge High Tibial Osteotomy: Plain Radiography Versus Computed Tomography. Arthroscopy 2018; 34:3073-3079. [PMID: 30292595 DOI: 10.1016/j.arthro.2018.06.041] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/07/2017] [Revised: 06/09/2018] [Accepted: 06/11/2018] [Indexed: 02/02/2023]
Abstract
PURPOSE To compare the accuracy of plain radiography and computed tomography (CT) in detecting lateral hinge fractures and to identify predictive factors of the lateral hinge fractures after open wedge high tibial osteotomy (HTO). METHODS This study included patients who underwent isolated primary open wedge HTO for medial compartment degenerative arthritis from 2015 to 2016 and were evaluated by postoperative CT scans and followed for a minimum of 1 year. This study involved 48 patients (48 knees) undergoing open wedge HTO for primary medial osteoarthritis. Lateral hinge fractures were evaluated on immediate plain radiographs and CT scans according to the Takeuchi classification. Predictive factors of plain radiograph-based hinge fracture and CT-based hinge fracture were investigated. RESULTS The detection rate of lateral hinge fracture was significantly higher on CT scans than on plain radiographs (50% vs 14.6%; P < .001). Seven knees (14.6%) showed lateral hinge fractures on postoperative plain radiographs, including 6 with type I and 1 with type III fractures; 24 (50.0%) showed lateral hinge fractures on postoperative CT scans, including 20 with type I, 2 with type II, and 2 with type III fractures. CT scans detected 14 type I, 2 type II, and 1 type III hinge fractures not detected by plain radiographs. The medial opening gap width was the only predictor of lateral hinge fracture on CT scans (adjusted odds ratio, 1.565; P =.034). CONCLUSIONS The incidence of lateral hinge fracture of the knee after open wedge HTO was higher on CT scans than on plain radiographs. The medial opening gap width was the only predictor of lateral hinge fractures, suggesting a need for care when spreading the gap to avoid lateral hinge fractures. LEVEL OF EVIDENCE Level III, cross-sectional study.
Collapse
Affiliation(s)
- Sung-Sahn Lee
- Department of Orthopaedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Haluk Celik
- Department of Orthopaedic Surgery, Umraniye Training and Research Hospital, Istanbul, Turkey
| | - Dae-Hee Lee
- Department of Orthopaedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
| |
Collapse
|