1
|
Williamson S, Daniel-Watanabe L, Finnemann J, Powell C, Teed A, Allen M, Paulus M, Khalsa SS, Fletcher PC. The Hybrid Excess and Decay (HED) model: an automated approach to characterising changes in the photoplethysmography pulse waveform. Wellcome Open Res 2022. [DOI: 10.12688/wellcomeopenres.17855.1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Photoplethysmography offers a widely used, convenient and non-invasive approach to monitoring basic indices of cardiovascular function, such as heart rate and blood oxygenation. Systematic analysis of the shape of the waveform generated by photoplethysmography might be useful to extract estimates of several physiological and psychological factors influencing the waveform. Here, we developed a robust and automated method for such a systematic analysis across individuals and across different physiological and psychological contexts. We describe a psychophysiologically-relevant model, the Hybrid Excess and Decay (HED) model, which characterises pulse wave morphology in terms of three underlying pressure waves and a decay function. We present the theoretical and practical basis for the model and demonstrate its performance when applied to a pharmacological dataset of 105 participants receiving intravenous administrations of the sympathomimetic drug isoproterenol (isoprenaline). We show that these parameters capture photoplethysmography data with a high degree of precision and, moreover, are sensitive to experimentally-induced changes in interoceptive arousal within individuals. We conclude by discussing the possible value in using the HED model as a complement to standard measures of photoplethysmography signals.
Collapse
|
2
|
Mynard JP, Kondiboyina A, Kowalski R, Cheung MMH, Smolich JJ. Measurement, Analysis and Interpretation of Pressure/Flow Waves in Blood Vessels. Front Physiol 2020; 11:1085. [PMID: 32973569 PMCID: PMC7481457 DOI: 10.3389/fphys.2020.01085] [Citation(s) in RCA: 40] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Accepted: 08/06/2020] [Indexed: 01/10/2023] Open
Abstract
The optimal performance of the cardiovascular system, as well as the break-down of this performance with disease, both involve complex biomechanical interactions between the heart, conduit vascular networks and microvascular beds. ‘Wave analysis’ refers to a group of techniques that provide valuable insight into these interactions by scrutinizing the shape of blood pressure and flow/velocity waveforms. The aim of this review paper is to provide a comprehensive introduction to wave analysis, with a focus on key concepts and practical application rather than mathematical derivations. We begin with an overview of invasive and non-invasive measurement techniques that can be used to obtain the signals required for wave analysis. We then review the most widely used wave analysis techniques—pulse wave analysis, wave separation and wave intensity analysis—and associated methods for estimating local wave speed or characteristic impedance that are required for decomposing waveforms into forward and backward wave components. This is followed by a discussion of the biomechanical phenomena that generate waves and the processes that modulate wave amplitude, both of which are critical for interpreting measured wave patterns. Finally, we provide a brief update on several emerging techniques/concepts in the wave analysis field, namely wave potential and the reservoir-excess pressure approach.
Collapse
Affiliation(s)
- Jonathan P Mynard
- Heart Research, Murdoch Children's Research Institute, Melbourne, VIC, Australia.,Department of Paediatrics, The University of Melbourne, Melbourne, VIC, Australia.,Department of Biomedical Engineering, The University of Melbourne, Melbourne, VIC, Australia.,Department of Cardiology, The Royal Children's Hospital, Parkville, VIC, Australia
| | - Avinash Kondiboyina
- Heart Research, Murdoch Children's Research Institute, Melbourne, VIC, Australia.,Department of Paediatrics, The University of Melbourne, Melbourne, VIC, Australia
| | - Remi Kowalski
- Heart Research, Murdoch Children's Research Institute, Melbourne, VIC, Australia.,Department of Paediatrics, The University of Melbourne, Melbourne, VIC, Australia.,Department of Cardiology, The Royal Children's Hospital, Parkville, VIC, Australia
| | - Michael M H Cheung
- Heart Research, Murdoch Children's Research Institute, Melbourne, VIC, Australia.,Department of Paediatrics, The University of Melbourne, Melbourne, VIC, Australia.,Department of Cardiology, The Royal Children's Hospital, Parkville, VIC, Australia
| | - Joseph J Smolich
- Heart Research, Murdoch Children's Research Institute, Melbourne, VIC, Australia.,Department of Paediatrics, The University of Melbourne, Melbourne, VIC, Australia
| |
Collapse
|
3
|
Balmer J, Pretty CG, Davidson S, Mehta-Wilson T, Desaive T, Smith R, Shaw GM, Chase JG. Clinically applicable model-based method, for physiologically accurate flow waveform and stroke volume estimation. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2020; 185:105125. [PMID: 31698169 DOI: 10.1016/j.cmpb.2019.105125] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/15/2019] [Revised: 08/10/2019] [Accepted: 10/07/2019] [Indexed: 06/10/2023]
Abstract
BACKGROUND AND OBJECTIVES Cardiovascular dysfunction can be more effectively monitored and treated, with accurate, continuous, stroke volume (SV) and/or cardiac output (CO) measurements. Since direct measurements of SV/CO are highly invasive, clinical measures are often discrete, or if continuous, can require recalibration with a discrete SV measurement after hemodynamic instability. This study presents a clinically applicable, non-additionally invasive, physiological model-based, SV and CO measurement method, which does not require recalibration during or after hemodynamic instability. METHODS AND RESULTS The model's ability to predict flow profiles and SV is assessed in an animal trial, using endotoxin to induce sepsis in 5 pigs. Mean percentage error between beat-to-beat SV measured from an aortic flow probe and estimated by the model was -2%, while 90% of estimations fell within -24.2% and +27.9% error. Error between estimated and measured changes in mean SV following interventions was less than 30% for 4 out of the 5 pigs. Correlations between model estimated and probe measured flow, for each pig and hemodynamic interventions, was r2 = 0.58 - 0.96, with 21 of the 25 pig intervention stages having r2 > 0.80. CONCLUSION The results demonstrate the model accurately estimates and tracks changes in flow profiles and resulting SV, without requiring model recalibration.
Collapse
Affiliation(s)
- Joel Balmer
- Department of Mechanical Engineering, University of Canterbury, New Zealand.
| | | | - Shaun Davidson
- Department of Mechanical Engineering, University of Canterbury, New Zealand
| | | | - Thomas Desaive
- GIGA Cardiovascular Science, University of Liège, Liège, Belgium
| | - Rachel Smith
- Department of Mechanical Engineering, University of Canterbury, New Zealand
| | | | - J Geoffrey Chase
- Department of Mechanical Engineering, University of Canterbury, New Zealand
| |
Collapse
|
4
|
Balmer J, Smith R, Pretty CG, Desaive T, Shaw GM, Chase JG. Accurate end systole detection in dicrotic notch-less arterial pressure waveforms. J Clin Monit Comput 2020; 35:79-88. [PMID: 32048103 DOI: 10.1007/s10877-020-00473-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2019] [Accepted: 01/24/2020] [Indexed: 11/26/2022]
Abstract
Identification of end systole is often necessary when studying events specific to systole or diastole, for example, models that estimate cardiac function and systolic time intervals like left ventricular ejection duration. In proximal arterial pressure waveforms, such as from the aorta, the dicrotic notch marks this transition from systole to diastole. However, distal arterial pressure measures are more common in a clinical setting, typically containing no dicrotic notch. This study defines a new end systole detection algorithm, for dicrotic notch-less arterial waveforms. The new algorithm utilises the beta distribution probability density function as a weighting function, which is adaptive based on previous heartbeats end systole locations. Its accuracy is compared with an existing end systole estimation method, on dicrotic notch-less distal pressure waveforms. Because there are no dicrotic notches defining end systole, validating which method performed better is more difficult. Thus, a validation method is developed using dicrotic notch locations from simultaneously measured aortic pressure, forward projected by pulse transit time (PTT) to the more distal pressure signal. Systolic durations, estimated by each of the end systole estimates, are then compared to the validation systolic duration provided by the PTT based end systole point. Data comes from ten pigs, across two protocols testing the algorithms under different hemodynamic states. The resulting mean difference ± limits of agreement between measured and estimated systolic duration, of [Formula: see text] versus [Formula: see text], for the new and existing algorithms respectively, indicate the new algorithms superiority.
Collapse
Affiliation(s)
- Joel Balmer
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand.
| | - Rachel Smith
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| | - Christopher G Pretty
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| | - Thomas Desaive
- GIGA Cardiovascular Science, University of Liège, Liège, Belgium
| | - Geoff M Shaw
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| | - J Geoffrey Chase
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| |
Collapse
|
5
|
Abstract
PURPOSE OF REVIEW Arterial pulse waveform analysis has a long tradition but has not pervaded medical routine yet. This review aims to answer the question whether the methodology is ready for prime time use. The current methodological consensus is assessed, existing technologies for waveform measurement and pulse wave analysis are discussed, and further needs for a widespread use are proposed. RECENT FINDINGS A consensus document on the understanding and analysis of the pulse waveform was published recently. Although still some discrepancies remain, the analysis using both pressure and flow waves is favoured. However, devices which enable pulse wave measurement are limited, and the comparability between devices is not sufficiently given. Pulse waveform analysis has the potential for prime time. It is currently on a way towards broader use, but still needs to overcome challenges before settling its role in medical routine.
Collapse
|