• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4613486)   Today's Articles (869)   Subscriber (49386)
For: Iwakoshi S, Nakai T, Ichihashi S, Inoue T, Sakaguchi S, Hirose T, Tabayashi N, Watkins AC, Kichikawa K. Conformability and Efficacy of the Zenith Spiral Z Leg Compared with the Zenith Flex Leg in Endovascular Abdominal Aortic Aneurysm Repair. Ann Vasc Surg 2019;59:127-133. [DOI: 10.1016/j.avsg.2019.02.013] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2019] [Revised: 02/21/2019] [Accepted: 02/22/2019] [Indexed: 10/26/2022]
Number Cited by Other Article(s)
1
Karelis A, Jonsson M, Budtz-Lilly J, Jirström W, Sonesson B, Dias NV. Multicentric Use of Commercially Available Infrarenal Endografts During Fenestrated Endovascular Aortic Repair: A Feasibility Study. J Endovasc Ther 2024:15266028241257090. [PMID: 38807416 DOI: 10.1177/15266028241257090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/30/2024]
2
Fujimura N, Ichihashi S, Shibata T, Matsumura H, Watanabe M, Morikage N, Kurimoto Y, Banno H, Uchiyama H, Obara H. Early Clinical Results From the Japanese Prospective Multicenter Study to Evaluate Zenith Alpha Abdominal Stent Graft for Abdominal Aortic Aneurysm (JUSTICE) Registry Demonstrate Acceptable Limb Patency at 12 Months. J Endovasc Ther 2024:15266028241248311. [PMID: 38654524 DOI: 10.1177/15266028241248311] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/26/2024]
3
Torrealba J, Panuccio G, Rohlffs F, Gandet T, Gronert C, Heidemann F, Tsilimparis N, Kölbel T. One-Year Results of ZBIS Iliac Branch Device With an Off-Label Connection Limb. J Endovasc Ther 2021;29:402-408. [PMID: 34711093 DOI: 10.1177/15266028211054760] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
4
Bogdanovic M, Stackelberg O, Lindström D, Ersryd S, Andersson M, Roos H, Siika A, Jonsson M, Roy J. Limb Graft Occlusion Following Endovascular Aneurysm Repair for Infrarenal Abdominal Aortic Aneurysm with the Zenith Alpha, Excluder, and Endurant Devices: a Multicentre Cohort Study. Eur J Vasc Endovasc Surg 2021;62:532-539. [PMID: 34266764 DOI: 10.1016/j.ejvs.2021.05.015] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2020] [Revised: 03/26/2021] [Accepted: 05/08/2021] [Indexed: 10/20/2022]
5
Fujimura N, Imazuru T, Matsumura H, Shibata T, Furuyama T, Kaneko K, Uchiyama H, Morikage N, Uchida T, Teshima E, Yamaoka T, Masuhara H, Ueda H, Arakawa M, Norimatsu T, Obara H, Onitsuka S. Two-Year Results of a Multicenter Prospective Observational Study of the Zenith Spiral-Z Limb Deployed in the External Iliac Artery During Endovascular Aneurysm Repair. Circ J 2020;84:1764-1770. [DOI: 10.1253/circj.cj-20-0195] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
6
Abdulrasak M, Sonesson B, Singh B, Resch T, Dias NV. Long-term outcomes of infrarenal endovascular aneurysm repair with a commercially available stent graft. J Vasc Surg 2020;72:520-530.e1. [DOI: 10.1016/j.jvs.2019.09.061] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2019] [Accepted: 09/29/2019] [Indexed: 12/21/2022]
7
de Niet A, Donselaar EJ, Holewijn S, Tielliu IFJ, Lardenoije JWHP, Zeebregts CJ, Reijnen MMPJ. Endograft Conformability in Fenestrated Endovascular Aneurysm Repair for Complex Abdominal Aortic Aneurysms. J Endovasc Ther 2020;27:848-856. [PMID: 32567964 PMCID: PMC7536524 DOI: 10.1177/1526602820936185] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
8
The Use of Iliac Branched Devices in the Acute Endovascular Repair of Ruptured Aortoiliac Aneurysms. Ann Vasc Surg 2020;67:171-177. [PMID: 32205247 DOI: 10.1016/j.avsg.2020.02.019] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2019] [Revised: 02/03/2020] [Accepted: 02/16/2020] [Indexed: 11/22/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA