1
|
Yang G, Shi R, Yang J, Tuo X. Optimization and shielding design of a thermal neutron device based on D-D neutron generator with Geant4 toolkit. Appl Radiat Isot 2024; 212:111483. [PMID: 39197420 DOI: 10.1016/j.apradiso.2024.111483] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2024] [Revised: 08/13/2024] [Accepted: 08/25/2024] [Indexed: 09/01/2024]
Abstract
Neutron activation analysis is a highly sensitive non-destructive testing technique with important applications in industry, geoscience, medical therapy, etc. This work designed and optimized a thermal neutron device that utilized a portable D-D neutron generator, and the Monte Carlo method with the Geant4 toolkit was applied to simulation. The objective of the optimized design is to maximize the thermal neutron flux at the output surface and increase the utilization efficiency of the neutron generator. A parameter K was defined as a measure of the device's slowing capacity for neutrons and was used to determine the optimized device geometry. The simulation considered the contribution of different types and sizes of moderators and reflectors to the thermal neutron intensity to obtain the optimal size. The shielding protection of the device was then designed. The effectiveness of shielding with different thicknesses was evaluated using three dose reference points. The results indicated that the optimized device can achieve a maximum thermal neutron flux of 1.97 × 105 n∙cm-2∙s-1 at the output surface by using high-density polyethylene (HDPE) as the moderator and nickel as the reflector. It was determined that using 45 cm of HDPE and 9 cm of lead protection in sequence along the neutron head axis would reduce the dose rate at the reference point, located 5 cm from the surface of the device, below the safety limit of 2.5 μSv/h.
Collapse
Affiliation(s)
- Guang Yang
- Chengdu University of Technology, Chengdu, 610059, China
| | - Rui Shi
- Sichuan University of Science & Engineering, Zigong, 643000, China.
| | - Jianbo Yang
- Sichuan University of Science & Engineering, Zigong, 643000, China
| | - Xianguo Tuo
- Chengdu University of Technology, Chengdu, 610059, China; Sichuan University of Science & Engineering, Zigong, 643000, China.
| |
Collapse
|
2
|
An P, Yang J, Wang T, Lu S, Wang D, Wang Z, Sun CL, Qin C, Li J. Layer-by-layer assembly of homopolypeptide polyelectrolytes on asymmetric nanochannels for the detection of nickel ions. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:2654-2660. [PMID: 38623688 DOI: 10.1039/d4ay00422a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/17/2024]
Abstract
Nickel stands out as one of the prevalent heavy metal ionic pollutants found in water. It is urgent to devise a simple, efficient, budget-friendly, highly-selective and proficient method for detecting Ni(II). This work reports an approach to design a nanofluidic diode for the ultrasensitive and label-free detection of nickel ions based on layer-by-layer assembly of polyarginine (PA) and polyglutamic acid (γ-PGA) on the inner surface of asymmetric nanochannels. We can tune the adsorption/desorption characteristics of the asymmetric nanochannels for Ni2+ by adjusting the pH changes, i.e., the PA-γ-PGA modified nanochannels adsorb Ni2+ at pH 6 and desorb at pH 3 in aqueous solution. This pivotal adjustment facilitates the reusable and specific detection of nickel ions with a detection limit of 1 × 10-8 M. Moreover, the system demonstrates commendable stability and recyclability, enhancing its practical applicability. This innovative system holds promise for recognizing and detecting nickel ions in diverse environments such as water, blood, and cells. The robust performance and adaptability of our proposed system instill confidence in its potential for future applications.
Collapse
Affiliation(s)
- Pengrong An
- Key Laboratory of Special Functional and Smart Polymer Materials of Ministry of Industry and Information Technology, School of Chemistry and Chemical Engineering, Northwestern Polytechnical University, No. 127, Youyi Road (West), Xi'an City, Shaanxi Province, 710072, P. R. China.
| | - Jincan Yang
- Key Laboratory of Special Functional and Smart Polymer Materials of Ministry of Industry and Information Technology, School of Chemistry and Chemical Engineering, Northwestern Polytechnical University, No. 127, Youyi Road (West), Xi'an City, Shaanxi Province, 710072, P. R. China.
| | - Tianming Wang
- Key Laboratory of Special Functional and Smart Polymer Materials of Ministry of Industry and Information Technology, School of Chemistry and Chemical Engineering, Northwestern Polytechnical University, No. 127, Youyi Road (West), Xi'an City, Shaanxi Province, 710072, P. R. China.
| | - Saiwen Lu
- Key Laboratory of Special Functional and Smart Polymer Materials of Ministry of Industry and Information Technology, School of Chemistry and Chemical Engineering, Northwestern Polytechnical University, No. 127, Youyi Road (West), Xi'an City, Shaanxi Province, 710072, P. R. China.
| | - Dehao Wang
- Key Laboratory of Special Functional and Smart Polymer Materials of Ministry of Industry and Information Technology, School of Chemistry and Chemical Engineering, Northwestern Polytechnical University, No. 127, Youyi Road (West), Xi'an City, Shaanxi Province, 710072, P. R. China.
| | - Zhuoyue Wang
- Key Laboratory of Special Functional and Smart Polymer Materials of Ministry of Industry and Information Technology, School of Chemistry and Chemical Engineering, Northwestern Polytechnical University, No. 127, Youyi Road (West), Xi'an City, Shaanxi Province, 710072, P. R. China.
| | - Chun-Lin Sun
- State Key Laboratory of Applied Organic Chemistry (SKLAOC), College of Chemistry and Chemical Engineering, Lanzhou University, No. 222, Tianshui Road (South), Lanzhou City, Gansu Province, 730000, P. R. China.
| | - Chuanguang Qin
- Key Laboratory of Special Functional and Smart Polymer Materials of Ministry of Industry and Information Technology, School of Chemistry and Chemical Engineering, Northwestern Polytechnical University, No. 127, Youyi Road (West), Xi'an City, Shaanxi Province, 710072, P. R. China.
| | - Jun Li
- Key Laboratory of Special Functional and Smart Polymer Materials of Ministry of Industry and Information Technology, School of Chemistry and Chemical Engineering, Northwestern Polytechnical University, No. 127, Youyi Road (West), Xi'an City, Shaanxi Province, 710072, P. R. China.
| |
Collapse
|
3
|
Improving a PGNAA Technique to Detect Heavy Metals in Solid Samples. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12083714] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Prompt gamma-ray neutron activation analysis (PGNAA) is a useful approach for determining the concentrations of a variety of elements in natural materials, either online or in situ, without affecting their chemical forms in matter. The current research aimed to improve the yield of a portable PGNAA setup using a dc beam of 2.5 MeV neutrons and a CeBr3 detector to record gamma rays from neutron inelastic scatterings. It is impossible to avoid the superimposition of heavy metal gamma rays and those from the detector’s element. However, tests were carried out to improve the signal-to-background ratio. By assessing the minimum detectable concentrations (MDC) of chrome, titanium, and zinc in soil samples, the effectiveness of the new optimization was confirmed. The study shows an improvement in the MDC values.
Collapse
|
4
|
Liadi FA, Naqvi AA, Khiari FZ, Raashid M. Phosphorus, sodium and sulphur measurements in compound samples using 2.5 MeV neutron activation. J Radioanal Nucl Chem 2022. [DOI: 10.1007/s10967-021-08185-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
5
|
Shielding design in neutron activation experiment system based on D-T neutron tube. NUCLEAR TECHNOLOGY AND RADIATION PROTECTION 2022. [DOI: 10.2298/ntrp2201042c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
Abstract
The deuterium-tritium neutron generator should be fully shielded for the
safety of the operators participating in the experiments since the D-T
neutron generator is commonly used in activation experiments. In this
study, MCNP5 code was used to simulate the shielding effect of the neutron
thermalization device previously designed by our group with Pb and
boron-containing polyethylene as the shielding material. The neutron dose
rate outside of the previous thermalization device can not meet the
requirement, so a concrete wall is needed between the device and the
operators. Two models are designed with concrete walls. One model is that
the device and the experimental operators are not in the same room, another
one is that the device and the experimental operators are in the same room,
and there is an L-shaped concrete wall between them. In both models, the
dose rate to the operators was less than 5 ?Svh-1.
Collapse
|
6
|
Guo C, Lv L, Liu Y, Ji M, Zang E, Liu Q, Zhang M, Li M. Applied Analytical Methods for Detecting Heavy Metals in Medicinal Plants. Crit Rev Anal Chem 2021; 53:339-359. [PMID: 34328385 DOI: 10.1080/10408347.2021.1953371] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
For thousands of years, medicinal plants (MPs) have been one of the main sources of drugs worldwide. However, recently, heavy metal pollution has seriously affected the quality and safety of MPs. Consuming MPs polluted by heavy metals such as Pb, Hg, and Cu significantly threaten the health of consumers. To manage this situation, the levels of heavy metals in MPs must be controlled. In recent years, this field has attracted significant attention, but few researchers have systematically summarized various analytical methods. Therefore, it is necessary to investigate methods that can accurately and effectively detect the amount of heavy metals in MPs. Herein, some important analytical methods used to detect heavy metals in MPs and their applications have been introduced and summarized in detail. These include atomic absorption spectrometry, atomic fluorescence spectrometry, inductively coupled plasma mass spectrometry, inductively coupled plasma atomic emission spectrometry, X-ray fluorescence spectrometry, neutron activation analysis, and anodic stripping voltammetry. The characteristics of these methods were subsequently compared and analyzed. In addition, high-performance liquid chromatography, ultraviolet spectrophotometry, and disposable electrochemical sensors have also been used for heavy metal detection in MPs. To elucidate the systematic and comprehensive information, these methods have also been briefly introduced in this review.
Collapse
Affiliation(s)
- Chunyan Guo
- College of Pharmacy, Qiqihar Medical University, Qiqihar, China
| | - Lijuan Lv
- Department of Basic Science, Tianjin Agricultural University, Tianjin, China
| | - Yuchao Liu
- College of Pharmacy, Qiqihar Medical University, Qiqihar, China
| | - Mingyue Ji
- Department of Pharmacy, Baotou Medical College, Baotou, China
| | - Erhuan Zang
- Department of Pharmacy, Baotou Medical College, Baotou, China
| | - Qian Liu
- Department of Pharmacy, Baotou Medical College, Baotou, China
| | - Min Zhang
- Department of Pharmacy, Baotou Medical College, Baotou, China
| | - Minhui Li
- College of Pharmacy, Qiqihar Medical University, Qiqihar, China.,Department of Pharmacy, Baotou Medical College, Baotou, China.,Pharmaceutical Laboratory, Inner Mongolia Institute of Traditional Chinese Medicine, Hohhot, China.,Inner Mongolia Engineering Research Center of the Planting and Development of Astragalus Membranaceus of the Geoherbs, Baotou Medical College, Baotou, China.,Inner Mongolia Key Laboratory of Characteristic Geoherbs Resources Protection and Utilization, Baotou Medical College, Baotou, China
| |
Collapse
|
7
|
He DD, Jing SW, Zheng YL. Design and optimization of thermal neutron device based on deuterium-deuterium neutron generator. FUSION ENGINEERING AND DESIGN 2021. [DOI: 10.1016/j.fusengdes.2021.112289] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
8
|
Structural and Secondary Electron Yield Properties of Titanium-Palladium Films with Laser-Treated Copper Substrate for Application in Neutron Generators. MATERIALS 2021; 14:ma14051222. [PMID: 33807628 PMCID: PMC7961749 DOI: 10.3390/ma14051222] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/27/2020] [Revised: 02/26/2021] [Accepted: 02/28/2021] [Indexed: 12/04/2022]
Abstract
Secondary electron emission (SEE) of the oxygen-free high-conductivity copper (OFHC) target surface in neutron generators limits the stability and improvement of the neutron yield. A novel-type target of titanium–palladium films coated on laser-treated OFHC target substrate was proposed and explored in this work to obtain low secondary electron yield (SEY) without introducing any components. The combination of Ti–Pd films and laser-treated OFHC substrate can effectively suppress secondary electron emission and enhance the adsorption ability to hydrogen isotopes with the existence of Pd film. The surface morphologies, surface chemical states, and SEYs of Ti–Pd films with laser-treated OFHC substrate were studied systematically for the first time. The XPS results showed that the laser-treated OFHC substrate surface was basically covered by Pd film. However, the Pd film surface was partially oxidized, with percentages of 21.31 and 10.02% for PdO and PdO2, respectively. The SEYs of Ti–Pd films with laser-treated OFHC substrate were all below 1 within the investigated primary energy range of 100–3000 eV, which would be sufficient for application in neutron generators. Specifically, the maximum SEY (δmax) of laser-treated OFHC substrate coated by Ti–Pd films was 0.87 with corresponding incident electron energy of 400 eV.
Collapse
|
9
|
Abdulrahman ST, Ahmad Z, Thomas S, Maria HJ, Rahman AA. Viscoelastic and thermal properties of natural
rubber low
‐density polyethylene composites with boric acid and borax. J Appl Polym Sci 2020. [DOI: 10.1002/app.49372] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
| | - Zakiah Ahmad
- Faculty of Civil EngineeringUniversiti Teknologi Mara Shah Alam Malaysia
| | - Sabu Thomas
- International and Inter University Centre for Nanoscience and NanotechnologySchool of Energy Materials, Mahatma Gandhi University Kottayam Kerala India
| | - Hanna J. Maria
- International and Inter University Centre for Nanoscience and NanotechnologySchool of Energy Materials, Mahatma Gandhi University Kottayam Kerala India
| | - Azerai Ali Rahman
- Faculty of Civil EngineeringUniversiti Teknologi Mara Shah Alam Malaysia
| |
Collapse
|
10
|
Sulfur analysis in bulk samples using a DD portable neutron generator based PGNAA setup. J Radioanal Nucl Chem 2020. [DOI: 10.1007/s10967-020-07329-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
11
|
Li C, Jing S, Xue H. Dose evaluation in a portable D–T neutron generator facility by Monte Carlo method. J Radioanal Nucl Chem 2020. [DOI: 10.1007/s10967-020-07090-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
12
|
Li C, Jing S, Gao Y, Zhang W. MCNP optimization of fast neutron beam thermalization device based on D-T neutron generator. FUSION ENGINEERING AND DESIGN 2020. [DOI: 10.1016/j.fusengdes.2019.111385] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
13
|
Evaluation of neutron and gamma dose in a new deuterium-deuterium fusion neutron generator facility using MCNP and experimental methods. Appl Radiat Isot 2019; 146:90-98. [DOI: 10.1016/j.apradiso.2019.01.030] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2018] [Revised: 01/19/2019] [Accepted: 01/31/2019] [Indexed: 11/17/2022]
|
14
|
Caccamo MT, Zammuto V, Gugliandolo C, Madeleine-Perdrillat C, Spanò A, Magazù S. Thermal restraint of a bacterial exopolysaccharide of shallow vent origin. Int J Biol Macromol 2018; 114:649-655. [DOI: 10.1016/j.ijbiomac.2018.03.160] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2018] [Revised: 03/23/2018] [Accepted: 03/26/2018] [Indexed: 10/17/2022]
|
15
|
Cannuli A, Caccamo MT, Castorina G, Colombo F, Magazù S. Laser Techniques on Acoustically Levitated Droplets. EPJ WEB OF CONFERENCES 2018. [DOI: 10.1051/epjconf/201816705010] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
This work reports the results of an experimental study where laser techniques are applied to
acoustically levitated droplets of trehalose aqueous solutions in order to perform spectroscopic analyses as a function of concentration and to test the theoretical diameter law. The study of such systems is important in order to better understand the behaviour of trehalose-synthesizing extremophiles that live in extreme environments. In particular, it will be shown how acoustic levitation, combined with optical spectroscopic instruments allows to explore a wide concentration range and to test the validity of the diameter law as a function of levitation lag time, i.e. the D2 vs t law. On this purpose a direct diameter monitoring by a video camera and a laser pointer was first performed; then the diameter was also evaluated by an indirect measure through an OH/CH band area ratio analysis of collected Raman and Infrared spectra. It clearly emerges that D2 vs t follows a linear trend for about 20 minutes, reaching then a plateau at longer time. This result shows how trehalose is able to avoid total water evaporation, this property being essential for the surviving of organisms under extreme environmental conditions.
Collapse
|
16
|
Angell CA, Magazù S, Migliardo F. Science for life - Recent advances in biochemical and biophysical methods. Biochim Biophys Acta Gen Subj 2016; 1861:3501-3503. [PMID: 27657805 DOI: 10.1016/j.bbagen.2016.09.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Affiliation(s)
- C Austen Angell
- School of Molecular Sciences, Arizona State University, Tempe, AZ 85287-1604, USA
| | - Salvatore Magazù
- Department of Mathematical and Informatics Sciences, Physical Sciences and Earth Sciences, University of Messina, Viale D'Alcontres 31, 98166 Messina, Italy
| | - Federica Migliardo
- Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, Viale D'Alcontres 31, 98166 Messina, Italy.
| |
Collapse
|