1
|
Al-yousif S, Najm IA, Talab HS, Hasan Al Qahtani N, Alfiras M, Al-Rawi OYM, Subhi Al-Dayyeni W, Amer Ahmed Alrawi A, Jabbar Mnati M, Jarrar M, Ghabban F, Al-Shareefi NA, Musa Jaber M, H. Saleh A, Md Tahir N, Najim HT, Taher M. Intrapartum cardiotocography trace pattern pre-processing, features extraction and fetal health condition diagnoses based on RCOG guideline. PeerJ Comput Sci 2022; 8:e1050. [PMID: 36092005 PMCID: PMC9454876 DOI: 10.7717/peerj-cs.1050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2021] [Accepted: 06/30/2022] [Indexed: 06/15/2023]
Abstract
CONTEXT The computerization of both fetal heart rate (FHR) and intelligent classification modeling of the cardiotocograph (CTG) is one of the approaches that are utilized in assisting obstetricians in conducting initial interpretation based on (CTG) analysis. CTG tracing interpretation is crucial for the monitoring of the fetal status during weeks into the pregnancy and childbirth. Most contemporary studies rely on computer-assisted fetal heart rate (FHR) feature extraction and CTG categorization to determine the best precise diagnosis for tracking fetal health during pregnancy. Furthermore, through the utilization of a computer-assisted fetal monitoring system, the FHR patterns can be precisely detected and categorized. OBJECTIVE The goal of this project is to create a reliable feature extraction algorithm for the FHR as well as a systematic and viable classifier for the CTG through the utilization of the MATLAB platform, all the while adhering to the recognized Royal College of Obstetricians and Gynecologists (RCOG) recommendations. METHOD The compiled CTG data from spiky artifacts were cleaned by a specifically created application and compensated for missing data using the guidelines provided by RCOG and the MATLAB toolbox after the implemented data has been processed and the FHR fundamental features have been extracted, for example, the baseline, acceleration, deceleration, and baseline variability. This is followed by the classification phase based on the MATLAB environment. Next, using the guideline provided by the RCOG, the signals patterns of CTG were classified into three categories specifically as normal, abnormal (suspicious), or pathological. Furthermore, to ensure the effectiveness of the created computerized procedure and confirm the robustness of the method, the visual interpretation performed by five obstetricians is compared with the results utilizing the computerized version for the 150 CTG signals. RESULTS The attained CTG signal categorization results revealed that there is variability, particularly a trivial dissimilarity of approximately (+/-4 and 6) beats per minute (b.p.m.). It was demonstrated that obstetricians' observations coincide with algorithms based on deceleration type and number, except for acceleration values that differ by up to (+/-4). DISCUSSION The results obtained based on CTG interpretation showed that the utilization of the computerized approach employed in infirmaries and home care services for pregnant women is indeed suitable. CONCLUSIONS The classification based on CTG that was used for the interpretation of the FHR attribute as discussed in this study is based on the RCOG guidelines. The system is evaluated and validated by experts based on their expert opinions and was compared with the CTG feature extraction and classification algorithms developed using MATLAB.
Collapse
Affiliation(s)
- Shahad Al-yousif
- Research Centre, The University of Almashreq, Baghdad, Iraq
- College of Engineering, Department of Electrical & Electronic Engineering, Gulf University, Almasnad, Kingdom of Bahrain
- Department of Medical Instrumentation Engineering Techniques, Dijlah University College, Baghdad, Iraq
| | - Ihab A. Najm
- College of Engineering, Tikrit University, Tikrit, Iraq
| | - Hossam Subhi Talab
- Children Welfare Teaching Hospital, Medical City, (MD, CABP, CAB Neonatology), Baghdad, Iraq
| | - Nourah Hasan Al Qahtani
- Department of Obstetrics and Gynecology, College of Medicine, Imam Abdulrahman Bin Faisal University, Al Dammam, Saudi Arabia
| | - M. Alfiras
- College of Engineering, Department of Electrical & Electronic Engineering, Gulf University, Almasnad, Kingdom of Bahrain
| | - Osama YM Al-Rawi
- College of Engineering, Department of Electrical & Electronic Engineering, Gulf University, Almasnad, Kingdom of Bahrain
| | | | | | - Mohannad Jabbar Mnati
- Department of Electronic Technology, Institute of Technology Baghdad, Middle Technical University, Baghdad, Iraq
| | - Mu’taman Jarrar
- College of Medicine, Imam Abdulrahman Bin Faisal University, Al Dammam, Saudi Arabia
| | - Fahad Ghabban
- Department of Information Systems College of Computer Science and Engineering, Taibah University, Al Madinah Al Munawwarah, Saudi Arabia
| | - Nael A. Al-Shareefi
- College of Biomedical Informatics, University of Information Technology and Communications (UOITC), Baghdad, Iraq
| | - Mustafa Musa Jaber
- Al-Turath University College, Department of Computer Engineering, Baghdad, Iraq
- Department of Medical Instruments Engineering Techniques, Al-Farahidi University, Baghdad, Iraq
| | | | - Nooritawati Md Tahir
- Electrical Engineering Department, College of Engineering, Universiti Teknologi MARA, Shah Alam, Malaysia
- Integrative Pharmacogenomics Institute (iPROMISE), Universiti Teknologi MARA, Shah Alam, Malaysia
- Institute of Big Data Analytics and Artificial Intelligence (IBDAAI), Universiti Teknologi MARA, Shah Alam, Malaysia
| | - Huda T. Najim
- Department of Biomedical Engineering, University of Technology, Baghdad, Iraq
| | - Mayada Taher
- Department of Laser and Optoelectronics Engineering, University of Technology, Baghdad, Iraq
| |
Collapse
|
2
|
Vargas-Calixto J, Warrick P, Kearney R. Estimation and Discriminability of Doppler Ultrasound Fetal Heart Rate Variability Measures. Front Artif Intell 2021; 4:674238. [PMID: 34490419 PMCID: PMC8417534 DOI: 10.3389/frai.2021.674238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2021] [Accepted: 07/27/2021] [Indexed: 11/20/2022] Open
Abstract
Continuous electronic fetal monitoring and the access to databases of fetal heart rate (FHR) data have sparked the application of machine learning classifiers to identify fetal pathologies. However, most fetal heart rate data are acquired using Doppler ultrasound (DUS). DUS signals use autocorrelation (AC) to estimate the average heartbeat period within a window. In consequence, DUS FHR signals loses high frequency information to an extent that depends on the length of the AC window. We examined the effect of this on the estimation bias and discriminability of frequency domain features: low frequency power (LF: 0.03–0.15 Hz), movement frequency power (MF: 0.15–0.5 Hz), high frequency power (HF: 0.5–1 Hz), the LF/(MF + HF) ratio, and the nonlinear approximate entropy (ApEn) as a function of AC window length and signal to noise ratio. We found that the average discriminability loss across all evaluated AC window lengths and SNRs was 10.99% for LF 14.23% for MF, 13.33% for the HF, 10.39% for the LF/(MF + HF) ratio, and 24.17% for ApEn. This indicates that the frequency domain features are more robust to the AC method and additive noise than the ApEn. This is likely because additive noise increases the irregularity of the signals, which results in an overestimation of ApEn. In conclusion, our study found that the LF features are the most robust to the effects of the AC method and noise. Future studies should investigate the effect of other variables such as signal drop, gestational age, and the length of the analysis window on the estimation of fHRV features and their discriminability.
Collapse
Affiliation(s)
| | - Philip Warrick
- Department of Biomedical Engineering, McGill University, Montreal, QC, Canada.,PeriGen Inc., Montreal, QC, Canada
| | - Robert Kearney
- Department of Biomedical Engineering, McGill University, Montreal, QC, Canada
| |
Collapse
|
3
|
Yang X, Zhang K, He J. Application and Clinical Analysis of Remote Fetal Heart Rate Monitoring Platform in Continuous Fetal Heart Rate Monitoring Images. JOURNAL OF HEALTHCARE ENGINEERING 2021; 2021:5517692. [PMID: 33824713 PMCID: PMC8007337 DOI: 10.1155/2021/5517692] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/06/2021] [Revised: 03/03/2021] [Accepted: 03/12/2021] [Indexed: 11/26/2022]
Abstract
Fetal heart sound is an important part of fetal monitoring and has attracted extensive research and attention from scholars at home and abroad in recent years. The fetal heart rate, extracted from the fetal heart sound signal, is one of the important indicators that reflect the health of the fetus in the womb. In this study, a maternal-fetal Holter monitor based on f ECG technology was used to collect maternal heart rate, fetal heart rate, and uterine contractions signals, isolate the fetal heart rate, and design an algorithm to extract the fetal heart rate baseline, acceleration, variation, wake-up cycle, and nonlinear parameters. Using statistical methods to analyze the average value and range of various characteristic parameters of fetal heart rate under continuous long-term monitoring, the results show that the baseline has a downward trend from 10 o'clock in the night to 4 o'clock in the morning and is the lowest around 2 o'clock in the morning. The area and acceleration time were significantly higher than those in the suspicious group. However, there was no significant difference in the number of acceleration values between the two groups; the proportion of small mutations in the normal group was lower than that of the suspicious group and the proportion of medium mutations was higher than that of the suspicious group. There is no statistically significant difference in maternal age, gestational age at childbirth, pregnancy comorbidities, and complication rates in the five-level interpretation system of ACOG (2009), RCOG (2007), SOGC (2007), and the United States (2007). The difference of pregnancy and parity in various images was statistically significant, P < 0.05. The second type of fetal heart rate monitoring images appeared in the highest among the diagnostic standards, and the difference in the second type of fetal heart rate monitoring images between the various diagnostic standards was statistically significant, P ≤ 0.001.
Collapse
Affiliation(s)
- Xuan Yang
- Women's Hospital School of Medicine Zhejiang University, HangZhou, ZheJiang 310006, China
| | - Ke Zhang
- Women's Hospital School of Medicine Zhejiang University, HangZhou, ZheJiang 310006, China
| | - Jianhu He
- Women's Hospital School of Medicine Zhejiang University, HangZhou, ZheJiang 310006, China
| |
Collapse
|
4
|
Kupka T, Matonia A, Jezewski M, Jezewski J, Horoba K, Wrobel J, Czabanski R, Martinek R. New Method for Beat-to-Beat Fetal Heart Rate Measurement Using Doppler Ultrasound Signal. SENSORS (BASEL, SWITZERLAND) 2020; 20:E4079. [PMID: 32707863 PMCID: PMC7435740 DOI: 10.3390/s20154079] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/27/2020] [Revised: 07/10/2020] [Accepted: 07/20/2020] [Indexed: 11/17/2022]
Abstract
The most commonly used method of fetal monitoring is based on heart activity analysis. Computer-aided fetal monitoring system enables extraction of clinically important information hidden for visual interpretation-the instantaneous fetal heart rate (FHR) variability. Today's fetal monitors are based on monitoring of mechanical activity of the fetal heart by means of Doppler ultrasound technique. The FHR is determined using autocorrelation methods, and thus it has a form of evenly spaced-every 250 ms-instantaneous measurements, where some of which are incorrect or duplicate. The parameters describing a beat-to-beat FHR variability calculated from such a signal show significant errors. The aim of our research was to develop new analysis methods that will both improve an accuracy of the FHR determination and provide FHR representation as time series of events. The study was carried out on simultaneously recorded (during labor) Doppler ultrasound signal and the reference direct fetal electrocardiogram Two subranges of Doppler bandwidths were separated to describe heart wall movements and valve motions. After reduction of signal complexity by determining the Doppler ultrasound envelope, the signal was analyzed to determine the FHR. The autocorrelation method supported by a trapezoidal prediction function was used. In the final stage, two different methods were developed to provide signal representation as time series of events: the first using correction of duplicate measurements and the second based on segmentation of instantaneous periodicity measurements. Thus, it ensured the mean heart interval measurement error of only 1.35 ms. In a case of beat-to-beat variability assessment the errors ranged from -1.9% to -10.1%. Comparing the obtained values to other published results clearly confirms that the new methods provides a higher accuracy of an interval measurement and a better reliability of the FHR variability estimation.
Collapse
Affiliation(s)
- Tomasz Kupka
- Łukasiewicz Research Network—Institute of Medical Technology and Equipment, PL41800 Zabrze, Poland; (A.M.); (J.J.); (K.H.); (J.W.)
| | - Adam Matonia
- Łukasiewicz Research Network—Institute of Medical Technology and Equipment, PL41800 Zabrze, Poland; (A.M.); (J.J.); (K.H.); (J.W.)
| | - Michal Jezewski
- Department of Cybernetics, Nanotechnology and Data Processing, Silesian University of Technology, PL44100 Gliwice, Poland; (M.J.); (R.C.)
| | - Janusz Jezewski
- Łukasiewicz Research Network—Institute of Medical Technology and Equipment, PL41800 Zabrze, Poland; (A.M.); (J.J.); (K.H.); (J.W.)
| | - Krzysztof Horoba
- Łukasiewicz Research Network—Institute of Medical Technology and Equipment, PL41800 Zabrze, Poland; (A.M.); (J.J.); (K.H.); (J.W.)
| | - Janusz Wrobel
- Łukasiewicz Research Network—Institute of Medical Technology and Equipment, PL41800 Zabrze, Poland; (A.M.); (J.J.); (K.H.); (J.W.)
| | - Robert Czabanski
- Department of Cybernetics, Nanotechnology and Data Processing, Silesian University of Technology, PL44100 Gliwice, Poland; (M.J.); (R.C.)
| | - Radek Martinek
- Department of Cybernetics and Biomedical Engineering, VSB—Technical University of Ostrava, 70800 Ostrava-Poruba, Czech Republic;
| |
Collapse
|