1
|
Mastrangelo R, Okada T, Ogura T, Ogura T, Baglioni P. Direct observation of the effects of chemical fixation in MNT-1 cells: A SE-ADM and Raman study. Proc Natl Acad Sci U S A 2023; 120:e2308088120. [PMID: 38091295 PMCID: PMC10743460 DOI: 10.1073/pnas.2308088120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Accepted: 10/16/2023] [Indexed: 12/18/2023] Open
Abstract
Aldehydes fixation was accidentally discovered in the early 20th century and soon became a widely adopted practice in the histological field, due to an excellent staining enhancement in tissues imaging. However, the fixation process itself entails cell proteins denaturation and crosslinking. The possible presence of artifacts, that depends on the specific system under observation, must therefore be considered to avoid data misinterpretation. This contribution takes advantage of scanning electron assisted-dielectric microscopy (SE-ADM) and Raman 2D imaging to reveal the possible presence and the nature of artifacts in unstained, and paraformldehyde, PFA, fixed MNT-1 cells. The high resolution of the innovative SE-ADM technique allowed the identification of globular protein clusters in the cell cytoplasm, formed after protein denaturation and crosslinking. Concurrently, SE-ADM images showed a preferential melanosome adsorption on the cluster's outer surface. The micron-sized aggregates were discernible in Raman 2D images, as the melanosomes signal, extracted through 2D principal component analysis, unequivocally mapped their location and distribution within the cells, appearing randomly distributed in the cytoplasm. Protein clusters were not observed in living MNT-1 cells. In this case, mature melanosomes accumulate preferentially at the cell periphery and are more closely packed than in fixed cells. Our results show that, although PFA does not affect the melanin structure, it disrupts melanosome distribution within the cells. Proteins secondary structure, conversely, is partially lost, as shown by the Raman signals related to α-helix, β-sheets, and specific amino acids that significantly decrease after the PFA treatment.
Collapse
Affiliation(s)
- Rosangela Mastrangelo
- Health and Medical Research Institute, National Institute of Advanced Industrial Science and Technology, Tsukuba305-8566, Japan
- NIKKOL GROUP Nikko Chemicals Co., Ltd., Tokyo174-0046, Japan
- Department of Chemistry and Consorzio Interuniversitario per lo Sviluppo dei Sistemi a Grande Interfase (Center for Colloid and Surface Science), University of Florence, FlorenceI-50019, Italy
| | - Tomoko Okada
- Health and Medical Research Institute, National Institute of Advanced Industrial Science and Technology, Tsukuba305-8566, Japan
| | - Taku Ogura
- NIKKOL GROUP Nikko Chemicals Co., Ltd., Tokyo174-0046, Japan
| | - Toshihiko Ogura
- Health and Medical Research Institute, National Institute of Advanced Industrial Science and Technology, Tsukuba305-8566, Japan
| | - Piero Baglioni
- Department of Chemistry and Consorzio Interuniversitario per lo Sviluppo dei Sistemi a Grande Interfase (Center for Colloid and Surface Science), University of Florence, FlorenceI-50019, Italy
| |
Collapse
|
2
|
Senga Y, Imamura H, Ogura T, Honda S. In-Solution Microscopic Imaging of Fractal Aggregates of a Stressed Therapeutic Antibody. Anal Chem 2019; 91:4640-4648. [PMID: 30888793 DOI: 10.1021/acs.analchem.8b05979] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Aggregates of therapeutic proteins that can contaminate drug products during manufacture is a growing concern for the pharmaceutical industry because the aggregates are potentially immunogenic. Electron microscopy is a typical, indispensable method for imaging nanometer- to micrometer-sized structures. Nevertheless, it is not ideal because it must be performed with ex situ monitoring under high-vacuum conditions, where the samples could be altered by staining and drying. Here, we introduce a scanning electron-assisted dielectric microscopy (SE-ADM) technique for in-solution imaging of monoclonal immunoglobulin G (IgG) aggregates without staining and drying. Remarkably, SE-ADM allowed assessment of the size and morphology of the IgG aggregates in solution by completely excluding drying-induced artifacts. SE-ADM was also beneficial to study IgG aggregation caused by temporary acid exposure followed by neutralization, pH-shift stress. A box-counting analysis of the SE-ADM images provided fractal dimensions of the larger aggregates, which complemented the fractal dimensions of the smaller aggregates measured by light scattering. The scale-free or self-similarity nature of the fractal aggregates indicated that a common mechanism for antibody aggregation existed between the smaller and larger aggregates. Consequently, SE-ADM is a useful method for characterizing protein aggregates to bridge the gaps that occur among conventional analytical methods, such as those related to in situ/ ex situ techniques or size/morphology assessments.
Collapse
Affiliation(s)
- Yukako Senga
- Biomedical Research Institute , National Institute of Advanced Industrial Science and Technology (AIST) , Higashi, Tsukuba , Ibaraki 305-8566 , Japan
| | - Hiroshi Imamura
- Biomedical Research Institute , National Institute of Advanced Industrial Science and Technology (AIST) , Higashi, Tsukuba , Ibaraki 305-8566 , Japan
| | - Toshihiko Ogura
- Biomedical Research Institute , National Institute of Advanced Industrial Science and Technology (AIST) , Higashi, Tsukuba , Ibaraki 305-8566 , Japan
| | - Shinya Honda
- Biomedical Research Institute , National Institute of Advanced Industrial Science and Technology (AIST) , Higashi, Tsukuba , Ibaraki 305-8566 , Japan
| |
Collapse
|
3
|
Direct imaging of uncoated biological samples enables correlation of super-resolution and electron microscopy data. Sci Rep 2018; 8:11610. [PMID: 30072703 PMCID: PMC6072772 DOI: 10.1038/s41598-018-29970-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2018] [Accepted: 07/23/2018] [Indexed: 11/08/2022] Open
Abstract
A simple method for imaging biological tissue samples by electron microscopy and its correlation with super-resolution light microscopy is presented. This room temperature protocol, based on protecting thin biological specimens with methylcellulose and imaging with low voltage scanning electron microscopy, circumvents complex classical electron microscopy sample preparation steps requiring dehydration, resin embedding and use of contrast agents. This technique facilitates visualization of subcellular structures e.g. synaptic clefts and synaptic vesicles in mouse brain tissue and the organization of mitochondrial cristae in the zebrafish retina. Application of immunogold protocols to these samples can determine the precise localization of synaptic proteins and, in combination with super-resolution light microscopy methods clearly pinpoints the subcellular distribution of several proteins in the tissue. The simplicity of the method, including section collection on a silicon wafer, reduces artefacts and correlates protein location with sample morphology.
Collapse
|
4
|
Ominami Y, Kawanishi S, Ushiki T, Ito S. A novel approach to scanning electron microscopy at ambient atmospheric pressure. Microscopy (Oxf) 2014; 64:97-104. [PMID: 25537435 DOI: 10.1093/jmicro/dfu107] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2014] [Accepted: 11/19/2014] [Indexed: 11/13/2022] Open
Abstract
Scanning electron microscopy (SEM) for observing samples at ambient atmospheric pressure is introduced in this study. An additional specimen chamber with a small window is inserted in the main specimen chamber, and the window is separated with a thin membrane or diaphragm allowing electron beam propagation. Close proximity of the sample to the membrane enables the detection of back-scattered electrons sufficient for imaging. In addition to the empirical imaging data, a probability analysis of the un-scattered fraction of the incident electron beam further supports the feasibility of atmospheric SEM imaging over a controlled membrane-sample distance.
Collapse
Affiliation(s)
- Yusuke Ominami
- Hitachi High-Technologies Corporation, Hitachinaka, Ibaraki 312-8504, Japan
| | - Shinsuke Kawanishi
- Hitachi High-Technologies Corporation, Hitachinaka, Ibaraki 312-8504, Japan
| | - Tatsuo Ushiki
- Niigata University Graduate School of Medical and Dental Sciences, Niigata city 951-9510, Japan
| | - Sukehiro Ito
- Hitachi High-Technologies Corporation, Hitachinaka, Ibaraki 312-8504, Japan
| |
Collapse
|
5
|
Ogura T. Direct observation of unstained biological specimens in water by the frequency transmission electric-field method using SEM. PLoS One 2014; 9:e92780. [PMID: 24651483 PMCID: PMC3961424 DOI: 10.1371/journal.pone.0092780] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2013] [Accepted: 02/25/2014] [Indexed: 11/18/2022] Open
Abstract
Scanning electron microscopy (SEM) is a powerful tool for the direct visualization of biological specimens at nanometre-scale resolution. However, images of unstained specimens in water using an atmospheric holder exhibit very poor contrast and heavy radiation damage. Here, we present a new form of microscopy, the frequency transmission electric-field (FTE) method using SEM, that offers low radiation damage and high-contrast observation of unstained biological samples in water. The wet biological specimens are enclosed in two silicon nitride (SiN) films. The metal-coated SiN film is irradiated using a focused modulation electron beam (EB) at a low-accelerating voltage. A measurement terminal under the sample holder detects the electric-field frequency signal, which contains structural information relating to the biological specimens. Our results in very little radiation damage to the sample, and the observation image is similar to the transmission image, depending on the sample volume. Our developed method can easily be utilized for the observation of various biological specimens in water.
Collapse
Affiliation(s)
- Toshihiko Ogura
- Biomedical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Umezono, Tsukuba, Ibaraki, Japan
- * E-mail:
| |
Collapse
|
6
|
Ogura T. High-contrast observation of unstained proteins and viruses by scanning electron microscopy. PLoS One 2012; 7:e46904. [PMID: 23056522 PMCID: PMC3466209 DOI: 10.1371/journal.pone.0046904] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2012] [Accepted: 09/06/2012] [Indexed: 01/09/2023] Open
Abstract
Scanning electron microscopy (SEM) is an important tool for the nanometre-scale analysis of the various samples. Imaging of biological specimens can be difficult for two reasons: (1) Samples must often be left unstained to observe detail of the biological structures; however, lack of staining significantly decreases image contrast. (2) Samples are prone to serious radiation damage from electron beam. Herein we report a novel method for sample preparation involving placement on a new metal-coated insulator film. This method enables obtaining high-contrast images from unstained proteins and viruses by scanning electron microscopy with minimal electron radiation damage. These images are similar to those obtained by transmission electron microscopy. In addition, the method can be easily used to observe specimens of proteins, viruses and other organic samples by using SEM.
Collapse
Affiliation(s)
- Toshihiko Ogura
- Biomedical Research Institute, National Institute of Advanced Industrial Science and Technology, Central 2, Umezono, Tsukuba, Ibaraki, Japan.
| |
Collapse
|
7
|
Ogura T. Direct observation of unstained wet biological samples by scanning-electron generation X-ray microscopy. Biochem Biophys Res Commun 2009; 391:198-202. [PMID: 19900411 DOI: 10.1016/j.bbrc.2009.11.031] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2009] [Accepted: 11/05/2009] [Indexed: 11/25/2022]
Abstract
Analytical tools of nanometre-scale resolution are indispensable in the fields of biology, physics and chemistry. One suitable tool, the soft X-ray microscope, provides high spatial resolution of visible light for wet specimens. For biological specimens, X-rays of water-window wavelength between carbon (284 eV; 4.3 nm) and oxygen (540 eV; 2.3 nm) absorption edges provide high-contrast imaging of biological samples in water. Among types of X-ray microscope, the transmission X-ray microscope using a synchrotron radiation source with diffractive zone plates offers the highest spatial resolution, approaching 15-10nm. However, even higher resolution is required to measure proteins and protein complexes in biological specimens; therefore, a new type of X-ray microscope with higher resolution that uses a simple light source is desirable. Here we report a novel scanning-electron generation X-ray microscope (SGXM) that demonstrates direct imaging of unstained wet biological specimens. We deposited wet yeasts in the space between two silicon nitride (Si(3)N(4)) films. A scanning electron beam of accelerating voltage 5 keV and current 1.6 nA irradiates the titanium (Ti)-coated Si(3)N(4) film, and the soft X-ray signal from it is detected by an X-ray photodiode (PD) placed below the sample. The SGXM can theoretically achieve better than 5 nm resolution. Our method can be utilized easily for various wet biological samples of bacteria, viruses, and protein complexes.
Collapse
Affiliation(s)
- Toshihiko Ogura
- Neuroscience Research Institute, National Institute of Advanced Industrial Science and Technology, Central 2, Tsukuba, Ibaraki 305-8568, Japan.
| |
Collapse
|
8
|
Measurement of the unstained biological sample by a novel scanning electron generation X-ray microscope based on SEM. Biochem Biophys Res Commun 2009; 385:624-9. [PMID: 19486897 DOI: 10.1016/j.bbrc.2009.05.107] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2009] [Accepted: 05/26/2009] [Indexed: 11/22/2022]
Abstract
We introduced a novel X-ray microscope system based on scanning electron microscopy using thin film, which enables the measurement of unstained biological samples without damage. An unstained yeast sample was adsorbed under a titanium (Ti)-coated silicon nitride (Si3N4) film 90 nm thick. The X-ray signal from the film was detected by an X-ray photodiode (PD) placed below the sample. With an electron beam at 2.6 kV acceleration and 6.75 nA current, the yeast image is obtained using the X-ray PD. The image is created by soft X-rays from the Ti layer. The Ti layer is effective in generating the characteristic 2.7-nm wavelength X-rays by the irradiation of electrons. Furthermore, we investigated the electron trajectory and the generation of the characteristic X-rays within the Ti-coated Si3N4 film by Monte Carlo simulation. Our system can be easily utilized to observe various unstained biological samples of cells, bacteria, and viruses.
Collapse
|
9
|
Ogura T. Analyzing indirect secondary electron contrast of unstained bacteriophage T4 based on SEM images and Monte Carlo simulations. Biochem Biophys Res Commun 2009; 380:254-9. [DOI: 10.1016/j.bbrc.2009.01.046] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2008] [Accepted: 01/13/2009] [Indexed: 11/26/2022]
|