1
|
Lv Y, Feng Z, Liu X, Zhang J, Yao C. The Enhancement of Tumor Ablation Effect by the Combination of High-Frequency and Low-Voltage Bipolar Electroporation Pulses. IEEE Trans Biomed Eng 2024; 71:1577-1586. [PMID: 38113160 DOI: 10.1109/tbme.2023.3344153] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2023]
Abstract
The H-FIRE (high-frequency irreversible electroporation) protocol employs high-frequency bipolar pulses (HFBPs) with a width of ∼1 µs for tumor ablation with slight muscle contraction. However, H-FIRE pulses need a higher electric field to generate a sufficient ablation effect, which may cause undesirable thermal damage. OBJECTIVE Recently, combining short high-voltage IRE monopolar pulses with long low-voltage IRE monopolar pulses was shown to enlarge the ablation region. This finding indicates that combining HFBPs with low-voltage bipolar pulses (LVBPs), which are called composited bipolar pulses (CBPs), may enhance the ablation effect. METHODS This study designed a pulse generator by modifying a full-bridge inverter. The cell suspension and 3D tumor mimic experiments (U251 cells) were performed to examine the enhancement of the ablation effect. RESULTS The generator outputs HFBPs with 0-±2.5 kV and LVBPs with 0-±0.3 kV in one period. The pulse parameters are adjustable by programming on a human-computer interface. The cell suspension experiments showed that CBPs could enhance cytotoxicity, as compared to HFBPs with no cell-killing effect. Even at lower electric energy, the cell viability by CBPs was significantly lower than that of the HFBPs protocol. The ablation experiments on the 3D tumor mimic showed that the CBPs could create a larger connected ablation area. In contrast, the HFBPs protocol with a similar dose generated a nonconnected ablation area. CONCLUSION Results indicate that the CBPs protocol can enhance the ablation effect of HFBPs protocol. SIGNIFICANCE This proposed generator that uses the CBPs principle may be a useful tool for tumor ablation.
Collapse
|
2
|
Rajagopalan NR, Munawar T, Sheehan MC, Fujimori M, Vista WR, Wimmer T, Gutta NB, Solomon SB, Srimathveeravalli G. Electrolysis products, reactive oxygen species and ATP loss contribute to cell death following irreversible electroporation with microsecond-long pulsed electric fields. Bioelectrochemistry 2024; 155:108579. [PMID: 37769509 PMCID: PMC10841515 DOI: 10.1016/j.bioelechem.2023.108579] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Revised: 09/13/2023] [Accepted: 09/21/2023] [Indexed: 10/03/2023]
Abstract
Membrane permeabilization and thermal injury are the major cause of cell death during irreversible electroporation (IRE) performed using high electric field strength (EFS) and small number of pulses. In this study, we explored cell death under conditions of reduced EFS and prolonged pulse application, identifying the contributions of electrolysis, reactive oxygen species (ROS) and ATP loss. We performed ablations with conventional high-voltage low pulse (HV-LP) and low-voltage high pulse (LV-HP) conditions in a 3D tumor mimic, finding equivalent ablation volumes when using 2000 V/cm 90 pulses or 1000 V/cm 900 pulses respectively. These results were confirmed by performing ablations in swine liver. In LV-HP treatment, ablation volume was found to increase proportionally with pulse numbers, without the substantial temperature increase seen with HV-LP parameters. Peri-electrode pH changes, ATP loss and ROS production were seen in both conditions, but LV-HP treatments were more sensitive to blocking of these forms of cell injury. Increases in current drawn during HV-LP was not observed during LV-HP condition where the total ablation volume correlated to the charge delivered into the tissue which was greater than HV-LP treatment. LV-HP treatment provides a new paradigm in using pulsed electric fields for tissue ablation with clinically relevant volumes.
Collapse
Affiliation(s)
| | - Tarek Munawar
- Department of Radiology, Interventional Radiology Service, Memorial Sloan-Kettering Cancer Center, NY, USA
| | - Mary Chase Sheehan
- Department of Mechanical and Industrial Engineering, University of Massachusetts Amherst, Amherst, MA, USA
| | | | - William-Ray Vista
- Department of Radiology, Interventional Radiology Service, Memorial Sloan-Kettering Cancer Center, NY, USA
| | - Thomas Wimmer
- Dept. of Radiology, Division of General Radiology, Medical University of Graz, Austria
| | | | - Stephen B Solomon
- Department of Radiology, Interventional Radiology Service, Memorial Sloan-Kettering Cancer Center, NY, USA
| | - Govindarajan Srimathveeravalli
- Department of Mechanical and Industrial Engineering, University of Massachusetts Amherst, Amherst, MA, USA; Institute for Applied Life Sciences, University of Massachusetts Amherst, Amherst, MA, USA.
| |
Collapse
|
3
|
Oshin EA, Minhas Z, Biancatelli RMLC, Catravas JD, Heller R, Guo S, Jiang C. Synergistic effects of nanosecond pulsed plasma and electric field on inactivation of pancreatic cancer cells in vitro. Sci Rep 2024; 14:885. [PMID: 38195698 PMCID: PMC10776738 DOI: 10.1038/s41598-024-51298-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2023] [Accepted: 01/03/2024] [Indexed: 01/11/2024] Open
Abstract
Nanosecond pulsed atmospheric pressure plasma jets (ns-APPJs) produce reactive plasma species, including charged particles and reactive oxygen and nitrogen species (RONS), which can induce oxidative stress in biological cells. Nanosecond pulsed electric field (nsPEF) has also been found to cause permeabilization of cell membranes and induce apoptosis or cell death. Combining the treatment of ns-APPJ and nsPEF may enhance the effectiveness of cancer cell inactivation with only moderate doses of both treatments. Employing ns-APPJ powered by 9 kV, 200 ns pulses at 2 kHz and 60-nsPEF of 50 kV/cm at 1 Hz, the synergistic effects on pancreatic cancer cells (Pan02) in vitro were evaluated on the metabolic activities of cells and transcellular electrical resistance (TER). It was observed that treatment with ns-APPJ for > 2 min disrupts Pan02 cell stability and resulted in over 30% cell death. Similarly, applying nsPEF alone, > 20 pulses resulted in over 15% cell death. While the inactivation activity from the individual treatment is moderate, combined treatments resulted in 80% cell death, approximately 3-to-fivefold increase compared to the individual treatment. In addition, reactive oxygen species such as OH and O were identified at the plasma-liquid interface. The gas temperature of the plasma and the temperature of the cell solution during treatments were determined to be near room temperature.
Collapse
Affiliation(s)
- Edwin A Oshin
- Frank Reidy Research Center for Bioelectrics, Old Dominion University, Norfolk, VA, 23455, USA
- Department of Electrical and Computer Engineering, Old Dominion University, Norfolk, VA, USA
| | - Zobia Minhas
- Frank Reidy Research Center for Bioelectrics, Old Dominion University, Norfolk, VA, 23455, USA
| | | | - John D Catravas
- Frank Reidy Research Center for Bioelectrics, Old Dominion University, Norfolk, VA, 23455, USA
- School of Medical Diagnostic and Translational Sciences, College of Health Sciences, Old Dominion University, Norfolk, VA, USA
| | - Richard Heller
- Department of Medical Engineering, University of South Florida, Tampa, FL, 33612, USA
| | - Siqi Guo
- Frank Reidy Research Center for Bioelectrics, Old Dominion University, Norfolk, VA, 23455, USA
| | - Chunqi Jiang
- Frank Reidy Research Center for Bioelectrics, Old Dominion University, Norfolk, VA, 23455, USA.
- Department of Electrical and Computer Engineering, Old Dominion University, Norfolk, VA, USA.
| |
Collapse
|
4
|
Kranjc M, Polajžer T, Novickij V, Miklavčič D. Determination of the Impact of High-Intensity Pulsed Electromagnetic Fields on the Release of Damage-Associated Molecular Pattern Molecules. Int J Mol Sci 2023; 24:14607. [PMID: 37834054 PMCID: PMC10572873 DOI: 10.3390/ijms241914607] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2023] [Revised: 09/22/2023] [Accepted: 09/25/2023] [Indexed: 10/15/2023] Open
Abstract
High-Intensity Pulsed Electromagnetic Fields (HI-PEMF) treatment is an emerging noninvasive and contactless alternative to conventional electroporation, since the electric field inside the tissue is induced remotely by an externally applied pulsed magnetic field. Recently, HI-PEMF has been successfully used in the transfer of plasmid DNA and siRNA in vivo, with no or minimal infiltration of immune cells. In addition to gene electrotransfer, treatment with HI-PEMF has also shown potential for electrochemotherapy, where activation of the immune response contributes to the treatment outcome. The immune response can be triggered by immunogenic cell death that is characterized by the release of damage-associated molecular patterns (DAMPs) from damaged or/and dying cells. In this study, the release of the best-known DAMP molecules, i.e., adenosine triphosphate (ATP), calreticulin and high mobility group box 1 protein (HMBG1), after HI-PEMF treatment was investigated in vitro on three different cell lines of different tissue origin and compared with conventional electroporation treatment parameters. We have shown that HI-PEMF by itself does not cause the release of HMGB1 or calreticulin, whereas the release of ATP was detected immediately after HI-PEMF treatment. Our results indicate that HI-PEMF treatment causes no to minimal release of DAMP molecules, which results in minimal/limited activation of the immune response.
Collapse
Affiliation(s)
- Matej Kranjc
- Faculty of Electrical Engineering, University of Ljubljana, Trzaska cesta 25, 1000 Ljubljana, Slovenia; (M.K.); (T.P.)
| | - Tamara Polajžer
- Faculty of Electrical Engineering, University of Ljubljana, Trzaska cesta 25, 1000 Ljubljana, Slovenia; (M.K.); (T.P.)
| | - Vitalij Novickij
- Institute of High Magnetic Fields, Faculty of Electronics, Vilnius Gediminas Technical University, Plytinės g. 27, 10105 Vilnius, Lithuania;
- Department of Immunology, State Research Institute Centre for Innovative Medicine, Santariskiu g. 5, 08410 Vilnius, Lithuania
| | - Damijan Miklavčič
- Faculty of Electrical Engineering, University of Ljubljana, Trzaska cesta 25, 1000 Ljubljana, Slovenia; (M.K.); (T.P.)
| |
Collapse
|
5
|
Oshin EA, Minhas Z, Biancatelli RMLC, Catravas JD, Heller R, Guo S, Jiang C. Synergistic effects of nanosecond pulsed plasma and electric field on inactivation of pancreatic cancer cells in vitro. RESEARCH SQUARE 2023:rs.3.rs-3143506. [PMID: 37546947 PMCID: PMC10402252 DOI: 10.21203/rs.3.rs-3143506/v1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/08/2023]
Abstract
Nanosecond pulsed atmospheric pressure plasma jets (ns-APPJs) produce reactive plasma species, including charged particles and reactive oxygen and nitrogen species (RONS), which can induce oxidative stress in biological cells. Nanosecond pulsed electric field (nsPEF) has also been found to cause permeabilization of cell membranes and induce apoptosis or cell death. Combining the treatment of ns-APPJ and nsPEF may enhance the effectiveness of cancer cell inactivation with only moderate doses of both treatments. Employing ns-APPJ powered by 9 kV, 200 ns pulses at 2 kHz and 60-nsPEF of 50 kV/cm at 1 Hz, the synergistic effects on pancreatic cancer cells (Pan02) in vitro were evaluated on cell viability and transcellular electrical resistance (TER). It was observed that treatment with ns-APPJ for >2 min disrupts Pan02 cell stability and resulted in over 30% cell death. Similarly, applying nsPEF alone, >20 pulses resulted in over 15% cell death. While the inactivation activity from the individual treatment is moderate, combined treatments resulted in 80% cell death, approximately 3-to-5-fold increase compared to the individual treatment. In addition, reactive oxygen species such as OH and O were identified at the plasma-liquid interface. The gas temperature of the plasma and the temperature of the cell solution during treatments were determined to be near room temperature.
Collapse
Affiliation(s)
- Edwin A Oshin
- Frank Reidy Research Center for Bioelectrics, Old Dominion University, Norfolk, VA 23455 USA
- Department of Electrical and Computer Engineering, Old Dominion University, Norfolk, VA, USA
| | - Zobia Minhas
- Frank Reidy Research Center for Bioelectrics, Old Dominion University, Norfolk, VA 23455 USA
| | | | - John D Catravas
- Frank Reidy Research Center for Bioelectrics, Old Dominion University, Norfolk, VA 23455 USA
- School of Medical Diagnostic and Translational Sciences, College of Health Sciences, Old Dominion University, Norfolk, VA, USA
| | - Richard Heller
- Department of Medical Engineering, University of South Florida, FL-33612 Tampa, USA
| | - Siqi Guo
- Frank Reidy Research Center for Bioelectrics, Old Dominion University, Norfolk, VA 23455 USA
| | - Chunqi Jiang
- Frank Reidy Research Center for Bioelectrics, Old Dominion University, Norfolk, VA 23455 USA
- Department of Electrical and Computer Engineering, Old Dominion University, Norfolk, VA, USA
| |
Collapse
|
6
|
Kranjc M, Dermol-Černe J, Potočnik T, Novickij V, Miklavčič D. High-Intensity Pulsed Electromagnetic Field-Mediated Gene Electrotransfection In Vitro. Int J Mol Sci 2022; 23:ijms23179543. [PMID: 36076938 PMCID: PMC9455820 DOI: 10.3390/ijms23179543] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2022] [Revised: 08/18/2022] [Accepted: 08/20/2022] [Indexed: 11/16/2022] Open
Abstract
A high-intensity pulsed electromagnetic field (HI-PEMF) is a non-invasive and non-contact delivery method and may, as such, have an advantage over gene electrotransfer mediated by conventional electroporation using contact electrodes. Due to the limited number of in vitro studies in the field of gene electrotransfection by HI-PEMF, we designed experiments to investigate and demonstrate the feasibility of such a technique for the non-viral delivery of genetic material into cells in vitro. We first showed that HI-PEMF causes DNA adsorption to the membrane, a generally accepted prerequisite step for successful gene electrotransfection. We also showed that HI-PEMF can induce gene electrotransfection as the application of HI-PEMF increased the percentage of GFP-positive cells for two different combinations of pDNA size and concentration. Furthermore, by measuring the uptake of larger molecules, i.e., fluorescently labelled dextrans of three different sizes, we showed endocytosis to be a possible mechanism for introducing large molecules into cells by HI-PEMF.
Collapse
Affiliation(s)
- Matej Kranjc
- Faculty of Electrical Engineering, University of Ljubljana, 1000 Ljubljana, Slovenia
| | - Janja Dermol-Černe
- Faculty of Electrical Engineering, University of Ljubljana, 1000 Ljubljana, Slovenia
| | - Tjaša Potočnik
- Faculty of Electrical Engineering, University of Ljubljana, 1000 Ljubljana, Slovenia
| | - Vitalij Novickij
- Faculty of Electronics, Vilnius Gediminas Technical University, 03227 Vilnius, Lithuania
| | - Damijan Miklavčič
- Faculty of Electrical Engineering, University of Ljubljana, 1000 Ljubljana, Slovenia
- Correspondence:
| |
Collapse
|
7
|
Aycock KN, Campelo SN, Salameh ZS, Vadlamani RA, Lorenzo MF, Davalos RV. Extended interpulse delays improve therapeutic efficacy of microsecond-duration pulsed electric fields. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2022; 2022:5021-5024. [PMID: 36086570 DOI: 10.1109/embc48229.2022.9871737] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Irreversible electroporation (IRE), or pulsed field ablation, employs microsecond-duration pulsed electric fields to generate targeted cellular damage without injury to the underlying tissue architecture. Biphasic, burst-type waveforms (termed high-frequency IRE, or H-FIRE) have garnered attention for their ability to elicit clinically relevant ablation volumes while reducing several undesirable side effects (muscle contractions/electrochemical effects) seen with monophasic pulses. Pulse width is generally the main (or only) parameter considered during burst construction, with little attention given to the delays within the burst. In this work, we tested the hypothesis that H-FIRE waveforms could be further optimized by manipulating only the interpulse delay between biphasic pulses within each burst. Using benchtop, ex vivo, and in vivo models, we demonstrate that extended interpulse delays (i.e., ~100 μs) reduce the severity of induced muscle contractions, alleviate mechanical tissue destruction, and minimize the chances of electrical arcing. Clinical Relevance- This proof-of-concept study shows that H-FIRE waveforms with extended interpulse delays provide several therapeutic benefits over conventional waveforms.
Collapse
|
8
|
Chiaramello E, Fiocchi S, Bonato M, Gallucci S, Benini M, Tognola G, Ravazzani P, Parazzini M. Gold nanoparticles as enablers of cell membrane permeabilization by time-varying magnetic field: influence of distance and geometry. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2022; 2022:4723-4726. [PMID: 36086609 DOI: 10.1109/embc48229.2022.9871079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
This study is based on the quantification of the influence of the presence of gold nanoparticles (Au NPs), of their geometry and their distance from cell membrane during time-varying electromagnetic fields cell membrane permeabilization on the pores opening dynamics. Results showed that the combined use of Au NPs and time-varying magnetic field can improve significantly the permeabilization of cell membrane. The presence of Au NPs allowed to reach transmembrane potential values enabling the cell membrane permeabilization only when placed at very short distance, equal to 20 nm. Both geometry and variability of the positioning in proximity of the cell membrane showed a strong influence on the probability of enabling pores opening. Clinical Relevance- This study provides a better comprehension about the mechanisms, still not completely understood, underlying cell membrane permeabilization by combining Au NPs and time-varying magnetic fields.
Collapse
|
9
|
Oshin EA, Guo S, Jiang C. Determining tissue conductivity in tissue ablation by nanosecond pulsed electric fields. Bioelectrochemistry 2022; 143:107949. [PMID: 34583212 PMCID: PMC8643318 DOI: 10.1016/j.bioelechem.2021.107949] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Revised: 09/10/2021] [Accepted: 09/15/2021] [Indexed: 02/03/2023]
Abstract
Nanosecond pulsed electric field (nsPEF) causes the permeabilization of the cell membrane and has been used to non-thermally treat cancerous tissues. As increased permeabilization in membranes were reported to be accompanied by impedance changes, the ablation effect of nsPEF on tissues can be monitored via the changes in tissue conductivity. In this study, effects of nsPEF on biological tissues were evaluated by determining the conductivities of potato and 4 T1-luc breast tumor tissues ex vivo from a murine model subjected to multiple 100-ns, 1-10 kV pulses. Using a four-needle electrode system with a calibrated electrode constant of 1.1 ± 0.1 cm, the conductivities of tissues was determined from both the network-analyzer measurement, before and after treatment, and voltage-current measurement in real-time. The conductivity of the potato tissue was measured for a frequency range of 0.1-3 MHz, and it increased with increasing pulse number and voltage amplitude. The conductivity of the tumor tissue was also observed to increase with pulse number and pulse voltage over a similar frequency range. In addition, the linear correlation between the ablation area in a treated potato tissue and the conductivity change in the tissue suggests that conductivity analysis of biological tissue under treatment could be a fast and sensitive approach to evaluate the effectiveness of a nsPEF treatment.
Collapse
Affiliation(s)
- Edwin A Oshin
- Frank Reidy Research Center for Bioelectrics, Old Dominion University, Norfolk, VA, USA; Department of Electrical and Computer Engineering, Old, Dominion University, Norfolk, VA, USA
| | - Siqi Guo
- Frank Reidy Research Center for Bioelectrics, Old Dominion University, Norfolk, VA, USA
| | - Chunqi Jiang
- Frank Reidy Research Center for Bioelectrics, Old Dominion University, Norfolk, VA, USA; Department of Electrical and Computer Engineering, Old, Dominion University, Norfolk, VA, USA.
| |
Collapse
|
10
|
Chiaramello E, Fiocchi S, Bonato M, Gallucci S, Benini M, Tognola G, Ravazzani P, Parazzini M. Contactless Cell Permeabilization by Time-Varying Magnetic fields: Modelling Transmembrane Potential and Mechanical Stress in in- vitro Experimental Set-Up. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2021; 2021:4303-4305. [PMID: 34892173 DOI: 10.1109/embc46164.2021.9629570] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
The feasibility of using time-varying magnetic field as a contactless cells permeabilization method was demonstrated by experimental results, but the underlying mechanism is still poorly understood. In this study a numerical analysis of the transmembrane potential (TMP) at cell membranes during permeabilization by time-varying magnetic fields was proposed, and a first quantification of mechanical stress induced by the magnetic and electric fields and hypothesized to play an important role in the permeabilization mechanism was carried out. TMP values induced by typical in-vitro experimental conditions were far below the values needed for membrane permeabilization, with a strong dependence on distance of the cell from the coil. The preliminary assessment of the mechanical pressure and potential deformation of cells showed that stress values evaluated in conditions in which TMP values were too low to cause membrane permeabilization were comparable to those known to influence the pore opening mechanisms.Clinical Relevance- Results represent a significant step towards a better comprehension of the mechanism underlying cell membrane permeabilization by time-varying magnetic fields.
Collapse
|
11
|
Cell transmembrane potential in contactless permeabilization by time-varying magnetic fields. Comput Biol Med 2021; 135:104587. [PMID: 34171642 DOI: 10.1016/j.compbiomed.2021.104587] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2021] [Revised: 06/10/2021] [Accepted: 06/14/2021] [Indexed: 11/22/2022]
Abstract
BACKGROUND Although experimental results proved the feasibility of using time-varying magnetic field as a contactless cells permeabilization method, the underlying mechanism is still poorly understood. In this study a numerical analysis of the time-dependent transmembrane potential (TMP) at cell membranes during permeabilization by time-varying magnetic fields was proposed, and a first quantification of mechanical stress induced by the magnetic and electric fields, hypothesized to play an important role in the permeabilization mechanism, was carried out. METHODS Starting from the simulation of real in vitro experimental conditions, the analysis was widened quantifying the influence of pulse frequency, cell dimension and distance of the cell from the magnetic field source. The mechanical pressure on cell membrane due to the interaction between free charges and induced electric field and due to the gradient of the magnetic field was quantified in all those conditions in which the TMP values were not high enough to cause membrane permeabilization. RESULTS TMP values induced by typical in-vitro experimental conditions were far below the values needed for membrane permeabilization, with a strong dependence on pulse frequency and distance of the cell from the coil. CONCLUSION The preliminary assessment of the mechanical pressure on cell membrane showed that stress values evaluated in conditions in which TMP values were too low to cause membrane permeabilization were comparable to those known to influence the pores opening mechanisms. Results represent a significant step towards a better comprehension of the mechanism underlying cell membrane permeabilization by time-varying magnetic fields.
Collapse
|
12
|
Novickij V, Stanevičienė R, Gruškienė R, Badokas K, Lukša J, Sereikaitė J, Mažeika K, Višniakov N, Novickij J, Servienė E. Inactivation of Bacteria Using Bioactive Nanoparticles and Alternating Magnetic Fields. NANOMATERIALS 2021; 11:nano11020342. [PMID: 33573001 PMCID: PMC7911490 DOI: 10.3390/nano11020342] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/17/2020] [Revised: 01/18/2021] [Accepted: 01/26/2021] [Indexed: 12/19/2022]
Abstract
Foodborne pathogens are frequently associated with risks and outbreaks of many diseases; therefore, food safety and processing remain a priority to control and minimize these risks. In this work, nisin-loaded magnetic nanoparticles were used and activated by alternating 10 and 125 mT (peak to peak) magnetic fields (AMFs) for biocontrol of bacteria Listeria innocua, a suitable model to study the inactivation of common foodborne pathogen L. monocytogenes. It was shown that L. innocua features high resistance to nisin-based bioactive nanoparticles, however, application of AMFs (15 and 30 min exposure) significantly potentiates the treatment resulting in considerable log reduction of viable cells. The morphological changes and the resulting cellular damage, which was induced by the synergistic treatment, was confirmed using scanning electron microscopy. The thermal effects were also estimated in the study. The results are useful for the development of new methods for treatment of the drug-resistant foodborne pathogens to minimize the risks of invasive infections. The proposed methodology is a contactless alternative to the currently established pulsed-electric field-based treatment in food processing.
Collapse
Affiliation(s)
- Vitalij Novickij
- Faculty of Electronics, Vilnius Gediminas Technical University, 03227 Vilnius, Lithuania;
- Correspondence: (V.N.); (E.S.)
| | - Ramunė Stanevičienė
- Laboratory of Genetics, Nature Research Centre, 08412 Vilnius, Lithuania; (R.S.); (J.L.)
| | - Rūta Gruškienė
- Faculty of Fundamental Sciences, Vilnius Gediminas Technical University, 10223 Vilnius, Lithuania; (R.G.); (J.S.)
| | - Kazimieras Badokas
- Institute of Photonics and Nanotechnology, Vilnius University, 10257 Vilnius, Lithuania;
| | - Juliana Lukša
- Laboratory of Genetics, Nature Research Centre, 08412 Vilnius, Lithuania; (R.S.); (J.L.)
| | - Jolanta Sereikaitė
- Faculty of Fundamental Sciences, Vilnius Gediminas Technical University, 10223 Vilnius, Lithuania; (R.G.); (J.S.)
| | - Kęstutis Mažeika
- Center for Physical Sciences and Technology, 02300 Vilnius, Lithuania;
| | - Nikolaj Višniakov
- Faculty of Mechanics, Vilnius Gediminas Technical University, 03224 Vilnius, Lithuania;
| | - Jurij Novickij
- Faculty of Electronics, Vilnius Gediminas Technical University, 03227 Vilnius, Lithuania;
| | - Elena Servienė
- Laboratory of Genetics, Nature Research Centre, 08412 Vilnius, Lithuania; (R.S.); (J.L.)
- Faculty of Fundamental Sciences, Vilnius Gediminas Technical University, 10223 Vilnius, Lithuania; (R.G.); (J.S.)
- Correspondence: (V.N.); (E.S.)
| |
Collapse
|
13
|
Concepts and Capabilities of In-House Built Nanosecond Pulsed Electric Field (nsPEF) Generators for Electroporation: State of Art. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10124244] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Electroporation is a pulsed electric field triggered phenomenon of cell permeabilization, which is extensively used in biomedical and biotechnological context. There is a growing scientific demand for high-voltage and/or high-frequency pulse generators for electropermeabilization of cells (electroporators). In the scope of this article we have reviewed the basic topologies of nanosecond pulsed electric field (nsPEF) generators for electroporation and the parametric capabilities of various in-house built devices, which were introduced in the last two decades. Classification of more than 60 various nsPEF generators was performed and pulse forming characteristics (pulse shape, voltage, duration and repetition frequency) were listed and compared. Lastly, the trends in the development of the electroporation technology were discussed.
Collapse
|
14
|
Miklavcic D, Novickij V, Kranjc M, Polajzer T, Haberl Meglic S, Batista Napotnik T, Romih R, Lisjak D. Contactless electroporation induced by high intensity pulsed electromagnetic fields via distributed nanoelectrodes. Bioelectrochemistry 2020; 132:107440. [DOI: 10.1016/j.bioelechem.2019.107440] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2019] [Revised: 12/03/2019] [Accepted: 12/05/2019] [Indexed: 12/19/2022]
|
15
|
Klein N, Mercadal B, Stehling M, Ivorra A. In vitro study on the mechanisms of action of electrolytic electroporation (E2). Bioelectrochemistry 2020; 133:107482. [PMID: 32062417 DOI: 10.1016/j.bioelechem.2020.107482] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2019] [Revised: 02/03/2020] [Accepted: 02/08/2020] [Indexed: 12/18/2022]
Abstract
Electrolytic Electroporation (E2) is the combination of reversible electroporation and electrolysis. It has been proposed as a novel treatment option to ablate tissue percutaneously. The present in vitro study in cells in suspension was performed to investigate the underlying mechanisms of action of E2. Different types of experiments were performed to isolate the effects of the electrolysis and the electroporation components of the treatment. Additionally, thermal simulations were performed to determine whether significant temperature increase contributes to the effect. The results indicate that E2's cell killing efficacy is due to a combinational effect of electrolysis and reversible electroporation that takes place within the first two minutes after E2 application. The results further show that cell death after E2 treatment is significantly delayed. These observations suggest that cell death is induced in permeabilized cells due to the uptake of electrolysis species. Thermal simulations revealed a significant but innocuous temperature increase.
Collapse
Affiliation(s)
- Nina Klein
- Department of Information and Communication Technologies, Universitat Pompeu Fabra, C/Roc Boronat 138, E-08018 Barcelona, Spain; Institut fur Bildgebende Diagnostik, Strahlenbergerstrasse 110, 63067 Offenbach, Germany; Inter Science GmbH, Reussblickstr 23, 6038 Gisikon, Lucerne, Switzerland; Catalan Industrial Doctorates Program, Spain.
| | - Borja Mercadal
- Department of Information and Communication Technologies, Universitat Pompeu Fabra, C/Roc Boronat 138, E-08018 Barcelona, Spain
| | - Michael Stehling
- Institut fur Bildgebende Diagnostik, Strahlenbergerstrasse 110, 63067 Offenbach, Germany; Inter Science GmbH, Reussblickstr 23, 6038 Gisikon, Lucerne, Switzerland
| | - Antoni Ivorra
- Department of Information and Communication Technologies, Universitat Pompeu Fabra, C/Roc Boronat 138, E-08018 Barcelona, Spain; Serra Húnter Fellow Programme, Universitat Pompeu Fabra, Barcelona, Spain
| |
Collapse
|
16
|
Guenther E, Klein N, Mikus P, Botea F, Pautov M, Lugnani F, Macchioro M, Popescu I, Stehling MK, Rubinsky B. Toward a clinical real time tissue ablation technology: combining electroporation and electrolysis (E2). PeerJ 2020; 8:e7985. [PMID: 31998549 PMCID: PMC6977482 DOI: 10.7717/peerj.7985] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2019] [Accepted: 10/03/2019] [Indexed: 01/05/2023] Open
Abstract
Background Percutaneous image-guided tissue ablation (IGA) plays a growing role in the clinical management of solid malignancies. Electroporation is used for IGA in several modalities: irreversible electroporation (IRE), and reversible electroporation with chemotoxic drugs, called electrochemotherapy (ECT). It was shown that the combination of electrolysis and electroporation—E2—affords tissue ablation with greater efficiency, that is, lower voltages, lower energy and shorter procedure times than IRE and without the need for chemotoxic additives as in ECT. Methods A new E2 waveform was designed that delivers optimal doses of electroporation and electrolysis in a single waveform. A series of experiments were performed in the liver of pigs to evaluate E2 in the context of clinical applications. The goal was to find initial parameter boundaries in terms of electrical field, pulse duration and charge as well as tissue behavior to enable real time tissue ablation of clinically relevant volumes. Results Histological results show that a single several hundred millisecond long E2 waveform can ablate large volume of tissue at relatively low voltages while preserving the integrity of large blood vessels and lumen structures in the ablation zone without the use of chemotoxic drugs or paralyzing drugs during anesthesia. This could translate clinically into much shorter treatment times and ease of use compared to other techniques that are currently applied.
Collapse
Affiliation(s)
- Enric Guenther
- Biophysics, Inter Science GmbH, Gisikon, Lucerne, Switzerland.,Department of Bioengineering and Department of Mechanical Engineering, University of California, Berkeley, Berkeley, CA, USA.,Institut fur Bildgebende Diagnostik, Offenbach, Germany
| | - Nina Klein
- Biophysics, Inter Science GmbH, Gisikon, Lucerne, Switzerland.,Institut fur Bildgebende Diagnostik, Offenbach, Germany.,Department of Information and Communication Technologies, Universitat Pompeu Fabra, Barcelona, Spain
| | - Paul Mikus
- Biophysics, Inter Science GmbH, Gisikon, Lucerne, Switzerland
| | - Florin Botea
- Center of General Surgery and Liver Transplantation, Fundeni Clinical Institute, Bucharest, Romania.,Center of Translational Medicine, Fundeni Clinical Institute, Bucharest, Romania
| | - Mihail Pautov
- Center of General Surgery and Liver Transplantation, Fundeni Clinical Institute, Bucharest, Romania.,Center of Translational Medicine, Fundeni Clinical Institute, Bucharest, Romania
| | | | | | - Irinel Popescu
- Center of General Surgery and Liver Transplantation, Fundeni Clinical Institute, Bucharest, Romania.,Center of Translational Medicine, Fundeni Clinical Institute, Bucharest, Romania
| | - Michael K Stehling
- Biophysics, Inter Science GmbH, Gisikon, Lucerne, Switzerland.,Department of Bioengineering and Department of Mechanical Engineering, University of California, Berkeley, Berkeley, CA, USA.,Institut fur Bildgebende Diagnostik, Offenbach, Germany
| | - Boris Rubinsky
- Biophysics, Inter Science GmbH, Gisikon, Lucerne, Switzerland.,Department of Bioengineering and Department of Mechanical Engineering, University of California, Berkeley, Berkeley, CA, USA
| |
Collapse
|
17
|
Klein N, Guenther E, Botea F, Pautov M, Dima S, Tomescu D, Popescu M, Ivorra A, Stehling M, Popescu I. The combination of electroporation and electrolysis (E2) employing different electrode arrays for ablation of large tissue volumes. PLoS One 2019; 14:e0221393. [PMID: 31437212 PMCID: PMC6705851 DOI: 10.1371/journal.pone.0221393] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2019] [Accepted: 08/06/2019] [Indexed: 11/18/2022] Open
Abstract
Background The combination of electroporation with electrolysis (E2) has previously been introduced as a novel tissue ablation technique. E2 allows the utilization of a wide parameter range and may therefore be a suitable technology for development of tissue-specific application protocols. Previous studies have implied that it is possible to achieve big lesions in liver in a very short time. The goal of this study was to test a variety of electrode configurations for the E2 application to ablate large tissue volumes. Materials and methods 27 lesions were performed in healthy porcine liver of five female pigs. Four, two and bipolar electrode-arrays were used to deliver various E2 treatment protocols. Liver was harvested approx. 20h after treatment and examined with H&E and Masson’s trichrome staining, and via TUNEL staining for selective specimen. Results All animals survived the treatments without complications. With four electrodes, a lesion of up to 35x35x35mm volume can be achieved in less than 30s. The prototype bipolar electrode created lesions of 50x18x18mm volume in less than 10s. Parameters for two-electrode ablations with large exposures encompassing large veins were found to be good in terms of vessel preservation, but not optimal to reliably close the gap between the electrodes. Conclusion This study demonstrates the ability to produce large lesions in liver within seconds at lower limits of the E2 parameter space at different electrode configurations. The applicability of E2 for single electrode ablations was demonstrated with bipolar electrodes. Parameters for large 4-electrode ablation volumes were found suitable, while parameters for two electrodes still need optimization. However, since the parameter space of E2 is large, it is possible that for all electrode geometries optimal waveforms and application protocols for specific tissues will emerge with continuing research.
Collapse
Affiliation(s)
- Nina Klein
- Inter Science GmbH, Lucerne, Switzerland
- Institut fur Bildgebende Diagnostik, Offenbach, Germany
- Department of Information and Communication Technologies, Universitat Pompeu Fabra, Barcelona, Spain
- * E-mail:
| | - Enric Guenther
- Inter Science GmbH, Lucerne, Switzerland
- Institut fur Bildgebende Diagnostik, Offenbach, Germany
| | - Florin Botea
- Center of General Surgery and Liver Transplantation–Fundeni Clinical Institute, Bucharest, Romania
- Center of Translational Medicine–Fundeni Clinical Institute, Bucharest, Romania
| | - Mihail Pautov
- Center of General Surgery and Liver Transplantation–Fundeni Clinical Institute, Bucharest, Romania
- Center of Translational Medicine–Fundeni Clinical Institute, Bucharest, Romania
| | - Simona Dima
- Center of General Surgery and Liver Transplantation–Fundeni Clinical Institute, Bucharest, Romania
- Center of Translational Medicine–Fundeni Clinical Institute, Bucharest, Romania
| | - Dana Tomescu
- Center of Translational Medicine–Fundeni Clinical Institute, Bucharest, Romania
- Department of Anesthesiology and Intensive Care 3, Fundeni Clinical Institute, Bucharest, Romania
| | - Mihai Popescu
- Center of Translational Medicine–Fundeni Clinical Institute, Bucharest, Romania
- Department of Anesthesiology and Intensive Care 3, Fundeni Clinical Institute, Bucharest, Romania
| | - Antoni Ivorra
- Department of Information and Communication Technologies, Universitat Pompeu Fabra, Barcelona, Spain
| | - Michael Stehling
- Inter Science GmbH, Lucerne, Switzerland
- Institut fur Bildgebende Diagnostik, Offenbach, Germany
| | - Irinel Popescu
- Center of General Surgery and Liver Transplantation–Fundeni Clinical Institute, Bucharest, Romania
- Center of Translational Medicine–Fundeni Clinical Institute, Bucharest, Romania
| |
Collapse
|
18
|
Lv Y, Yao C, Rubinsky B. A 2-D Cell Layer Study on Synergistic Combinations of High-Voltage and Low-Voltage Irreversible Electroporation Pulses. IEEE Trans Biomed Eng 2019; 67:957-965. [PMID: 31265380 DOI: 10.1109/tbme.2019.2925774] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Irreversible electroporation (IRE) employs brief, high-electric field pulses to ablate tumors while preserving the extracellular matrix. Recently, we showed that combining short high-voltage (SHV) IRE pulses and long low-voltage (LLV) IRE pulses can enlarge the tissue ablation region, presumably through a synergistic effect. OBJECTIVE The goal of this study is to further investigate the effect of this combination on a 2-D cell layer tumor model. METHODS 2-D layers of tumor cells are exposed to various SHV and LLV combinations, and the results of propidium iodide (PI) and fluorescein diacetate staining are examined to correlate treatment protocols with the ensuing irreversible and reversible electroporation areas. RESULTS The combination of SHV+LLV pulses produces a larger area of electroporation and ablation than LLV+SHV pulses, LLV pulses alone, and SHV pulses alone. CONCLUSION Judiciously combining SHV and LLV pulses can produce a synergistic effect that enlarges the electroporation-induced ablation area. A hypothetical explanation for this effect is that it involves a combination of pore expansion and electrolysis induced by LLV pulses in the area that had been reversibly permeabilized by the SHV pulses. SIGNIFICANCE This paper is valuable for the design of improved IRE protocols and provides a hypothesis for the mechanisms involved.
Collapse
|
19
|
A Conceivable Mechanism Responsible for the Synergy of High and Low Voltage Irreversible Electroporation Pulses. Ann Biomed Eng 2019; 47:1552-1563. [PMID: 30953220 DOI: 10.1007/s10439-019-02258-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2018] [Accepted: 03/29/2019] [Indexed: 12/12/2022]
Abstract
Irreversible electroporation (IRE), is a new non-thermal tissue ablation technology in which brief high electric field pulses are delivered across the target tissue to induce cell death by irreversible permeabilization of the cell membrane. A deficiency of conventional IRE is that the ablation zone is relatively small, bounded by the irreversible electroporation isoelectric field margin. In the previous studies we have introduced a new treatment protocol that combines few short high voltage (SHV) pulses with long low-voltage (LLV) pulses. In the previous studies, we also have shown that the addition of few SHV pulses increases by almost a factor of two the area ablated by a protocol that employs only the LLV pulses. This study employs potato and gel phantom to generate a plausible explanation for the mechanism. The study provides circumstantial evidence that the mechanism involved is the production of electrolytic compounds by the LLV pulse sequence, which causes tissue ablation beyond the margin of the irreversible electroporation isoelectric field generated by the SHV pulses, presumable to the reversible electroporation isoelectric field margin generated by the SHV pulses.
Collapse
|
20
|
Zhao Y, Liu H, Bhonsle SP, Wang Y, Davalos RV, Yao C. Ablation outcome of irreversible electroporation on potato monitored by impedance spectrum under multi-electrode system. Biomed Eng Online 2018; 17:126. [PMID: 30236121 PMCID: PMC6148960 DOI: 10.1186/s12938-018-0562-9] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2018] [Accepted: 09/17/2018] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Irreversible electroporation (IRE) therapy relies on pulsed electric fields to non-thermally ablate cancerous tissue. Methods for evaluating IRE ablation in situ are critical to assessing treatment outcome. Analyzing changes in tissue impedance caused by electroporation has been proposed as a method for quantifying IRE ablation. In this paper, we assess the hypothesis that irreversible electroporation ablation outcome can be monitored using the impedance change measured by the electrode pairs not in use, getting more information about the ablation size in different directions. METHODS Using a square four-electrode configuration, the two diagonal electrodes were used to electroporate potato tissue. Next, the impedance changes, before and after treatment, were measured from different electrode pairs and the impedance information was extracted by fitting the data to an equivalent circuit model. Finally, we correlated the change of impedance from various electrode pairs to the ablation geometry through the use of fitted functions; then these functions were used to predict the ablation size and compared to the numerical simulation results. RESULTS The change in impedance from the electrodes used to apply pulses is larger and has higher deviation than the other electrode pairs. The ablation size and the change in resistance in the circuit model correlate with various linear functions. The coefficients of determination for the three functions are 0.8121, 0.8188 and 0.8691, respectively, showing satisfactory agreement. The functions can well predict the ablation size under different pulse numbers, and in some directions it did even better than the numerical simulation method, which used different electric field thresholds for different pulse numbers. CONCLUSIONS The relative change in tissue impedance measured from the non-energized electrodes can be used to assess ablation size during treatment with IRE according to linear functions.
Collapse
Affiliation(s)
- Yajun Zhao
- State Key Laboratory of Power Transmission Equipment and System Security and New Technology, School of Electrical Engineering, Chongqing University, No. 174 Shazhengjie, Shapingba District, Chongqing, 400044, China.,Department of Biomedical Engineering and Mechanics, Virginia Tech, 329 ICTAS Stanger St (0298), Blacksburg, VA, 24061, USA
| | - Hongmei Liu
- State Key Laboratory of Power Transmission Equipment and System Security and New Technology, School of Electrical Engineering, Chongqing University, No. 174 Shazhengjie, Shapingba District, Chongqing, 400044, China
| | - Suyashree P Bhonsle
- Department of Biomedical Engineering and Mechanics, Virginia Tech, 329 ICTAS Stanger St (0298), Blacksburg, VA, 24061, USA
| | - Yilin Wang
- State Key Laboratory of Power Transmission Equipment and System Security and New Technology, School of Electrical Engineering, Chongqing University, No. 174 Shazhengjie, Shapingba District, Chongqing, 400044, China
| | - Rafael V Davalos
- Department of Biomedical Engineering and Mechanics, Virginia Tech, 329 ICTAS Stanger St (0298), Blacksburg, VA, 24061, USA.
| | - Chenguo Yao
- State Key Laboratory of Power Transmission Equipment and System Security and New Technology, School of Electrical Engineering, Chongqing University, No. 174 Shazhengjie, Shapingba District, Chongqing, 400044, China.
| |
Collapse
|
21
|
Conductivity Rise During Irreversible Electroporation: True Permeabilization or Heat? Cardiovasc Intervent Radiol 2018; 41:1257-1266. [PMID: 29687261 PMCID: PMC6021471 DOI: 10.1007/s00270-018-1971-7] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/22/2018] [Accepted: 04/18/2018] [Indexed: 12/18/2022]
Abstract
Purpose Irreversible electroporation (IRE) induces apoptosis with high-voltage electric pulses. Although the working mechanism is non-thermal, development of secondary Joule heating occurs. This study investigated whether the observed conductivity rise during IRE is caused by increased cellular permeabilization or heat development. Methods IRE was performed in a gelatin tissue phantom, in potato tubers, and in 30 patients with unresectable colorectal liver metastases (CRLM). Continuous versus sequential pulsing protocols (10-90 vs. 10-30-30-30) were assessed. Temperature was measured using fiber-optic probes. After temperature had returned to baseline, 100 additional pulses were delivered. The primary technique efficacy of the treated CRLM was compared to the periprocedural current rise. Seven patients received ten additional pulses after a 10-min cool-down period. Results Temperature and current rise was higher for the continuous pulsing protocol (medians, gel: 13.05 vs. 9.55 °C and 9 amperes (A) vs. 7A; potato: 12.70 vs. 10.53 °C and 6.0A vs. 6.5A). After cooling-down, current returned to baseline in the gel phantom and near baseline values (Δ2A with continuous- and Δ5A with sequential pulsing) in the potato tubers. The current declined after cooling-down in all seven patients with CRLM, although baseline values were not reached. There was a positive correlation between current rise and primary technique efficacy (p = 0.02); however, the previously reported current increase threshold of 12–15A was reached in 13%. Conclusion The observed conductivity rise during IRE is caused by both cellular permeabilization and heat development. Although a correlation between current rise and efficacy exists, the current increase threshold seems unfeasible for CRLM. Electronic supplementary material The online version of this article (10.1007/s00270-018-1971-7) contains supplementary material, which is available to authorized users.
Collapse
|
22
|
High frequency electroporation efficiency is under control of membrane capacitive charging and voltage potential relaxation. Bioelectrochemistry 2018; 119:92-97. [DOI: 10.1016/j.bioelechem.2017.09.006] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2017] [Revised: 09/13/2017] [Accepted: 09/13/2017] [Indexed: 01/13/2023]
|
23
|
Novickij V, Dermol J, Grainys A, Kranjc M, Miklavčič D. Membrane permeabilization of mammalian cells using bursts of high magnetic field pulses. PeerJ 2017; 5:e3267. [PMID: 28462057 PMCID: PMC5408723 DOI: 10.7717/peerj.3267] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2017] [Accepted: 04/02/2017] [Indexed: 11/20/2022] Open
Abstract
BACKGROUND Cell membrane permeabilization by pulsed electromagnetic fields (PEMF) is a novel contactless method which results in effects similar to conventional electroporation. The non-invasiveness of the methodology, independence from the biological object homogeneity and electrical conductance introduce high flexibility and potential applicability of the PEMF in biomedicine, food processing, and biotechnology. The inferior effectiveness of the PEMF permeabilization compared to standard electroporation and the lack of clear description of the induced transmembrane transport are currently of major concern. METHODS The PEMF permeabilization experiments have been performed using a 5.5 T, 1.2 J pulse generator with a multilayer inductor as an applicator. We investigated the feasibility to increase membrane permeability of Chinese Hamster Ovary (CHO) cells using short microsecond (15 µs) pulse bursts (100 or 200 pulses) at low frequency (1 Hz) and high dB/dt (>106 T/s). The effectiveness of the treatment was evaluated by fluorescence microscopy and flow cytometry using two different fluorescent dyes: propidium iodide (PI) and YO-PRO®-1 (YP). The results were compared to conventional electroporation (single pulse, 1.2 kV/cm, 100 µs), i.e., positive control. RESULTS The proposed PEMF protocols (both for 100 and 200 pulses) resulted in increased number of permeable cells (70 ± 11% for PI and 67 ± 9% for YP). Both cell permeabilization assays also showed a significant (8 ± 2% for PI and 35 ± 14% for YP) increase in fluorescence intensity indicating membrane permeabilization. The survival was not affected. DISCUSSION The obtained results demonstrate the potential of PEMF as a contactless treatment for achieving reversible permeabilization of biological cells. Similar to electroporation, the PEMF permeabilization efficacy is influenced by pulse parameters in a dose-dependent manner.
Collapse
Affiliation(s)
- Vitalij Novickij
- Institute of High Magnetic Fields, Vilnius Gediminas Technical University, Vilnius, Lithuania
| | - Janja Dermol
- Faculty of Electrical Engineering, University of Ljubljana, Ljubljana, Slovenia
| | - Audrius Grainys
- Institute of High Magnetic Fields, Vilnius Gediminas Technical University, Vilnius, Lithuania
| | - Matej Kranjc
- Faculty of Electrical Engineering, University of Ljubljana, Ljubljana, Slovenia
| | - Damijan Miklavčič
- Faculty of Electrical Engineering, University of Ljubljana, Ljubljana, Slovenia
| |
Collapse
|
24
|
Klein N, Guenther E, Mikus P, Stehling MK, Rubinsky B. Single exponential decay waveform; a synergistic combination of electroporation and electrolysis (E2) for tissue ablation. PeerJ 2017; 5:e3190. [PMID: 28439465 PMCID: PMC5398292 DOI: 10.7717/peerj.3190] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2016] [Accepted: 03/15/2017] [Indexed: 12/18/2022] Open
Abstract
Background Electrolytic ablation and electroporation based ablation are minimally invasive, non-thermal surgical technologies that employ electrical currents and electric fields to ablate undesirable cells in a volume of tissue. In this study, we explore the attributes of a new tissue ablation technology that simultaneously delivers a synergistic combination of electroporation and electrolysis (E2). Method A new device that delivers a controlled dose of electroporation field and electrolysis currents in the form of a single exponential decay waveform (EDW) was applied to the pig liver, and the effect of various parameters on the extent of tissue ablation was examined with histology. Results Histological analysis shows that E2 delivered as EDW can produce tissue ablation in volumes of clinical significance, using electrical and temporal parameters which, if used in electroporation or electrolysis separately, cannot ablate the tissue. Discussion The E2 combination has advantages over the three basic technologies of non-thermal ablation: electrolytic ablation, electrochemical ablation (reversible electroporation with injection of drugs) and irreversible electroporation. E2 ablates clinically relevant volumes of tissue in a shorter period of time than electrolysis and electroporation, without the need to inject drugs as in reversible electroporation or use paralyzing anesthesia as in irreversible electroporation.
Collapse
Affiliation(s)
- Nina Klein
- Inter Science GmbH, Gisikon, Switzerland.,Prostata Center, Institut fur Bildgebende Diagnostik, Offenbach, Germany
| | - Enric Guenther
- Inter Science GmbH, Gisikon, Switzerland.,Prostata Center, Institut fur Bildgebende Diagnostik, Offenbach, Germany
| | - Paul Mikus
- Inter Science GmbH, Gisikon, Switzerland
| | - Michael K Stehling
- Inter Science GmbH, Gisikon, Switzerland.,Prostata Center, Institut fur Bildgebende Diagnostik, Offenbach, Germany
| | - Boris Rubinsky
- Inter Science GmbH, Gisikon, Switzerland.,Department of Mechanical Engineering, University of California, Berkeley, CA, United States
| |
Collapse
|
25
|
Novickij V, Lastauskienė E, Švedienė J, Grainys A, Staigvila G, Paškevičius A, Girkontaitė I, Zinkevičienė A, Markovskaja S, Novickij J. Membrane Permeabilization of Pathogenic Yeast in Alternating Sub-microsecond Electromagnetic Fields in Combination with Conventional Electroporation. J Membr Biol 2017; 251:189-195. [PMID: 28238117 DOI: 10.1007/s00232-017-9951-4] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2017] [Accepted: 02/15/2017] [Indexed: 12/14/2022]
Abstract
Recently, a novel contactless treatment method based on high-power pulsed electromagnetic fields (PEMF) was proposed, which results in cell membrane permeabilization effects similar to electroporation. In this work, a new PEMF generator based on multi-stage Marx circuit topology, which is capable of delivering 3.3 T, 0.19 kV/cm sub-microsecond pulses was used to permeabilize pathogenic yeast Candida albicans separately and in combination with conventional square wave electroporation (8-17 kV/cm, 100 μs). Bursts of 10, 25, and 50 PEMF pulses were used. The yeast permeabilization rate was evaluated using flow cytometric analysis and propidium iodide (PI) assay. A statistically significant (P < 0.05) combinatorial effect of electroporation and PEMF treatment was detected. Also the PEMF treatment (3.3 T, 50 pulses) resulted in up to 21% loss of yeast viability, and a dose-dependent additive effect with pulsed electric field was observed. As expected, increase of the dB/dt and subsequently the induced electric field amplitude resulted in a detectable effect solely by PEMF, which was not achievable before for yeasts in vitro.
Collapse
Affiliation(s)
- Vitalij Novickij
- Institute of High Magnetic Fields, Vilnius Gediminas Technical University, Naugarduko st. 41, 03227, Vilnius, Lithuania.
| | - Eglė Lastauskienė
- Department of Microbiology and Biotechnology, Vilnius University, Sauletekio al. 7, 10257, Vilnius, Lithuania
| | - Jurgita Švedienė
- Laboratory of Biodeterioration Research, Nature Research Centre, Akademijos st. 2, 08412, Vilnius, Lithuania
| | - Audrius Grainys
- Institute of High Magnetic Fields, Vilnius Gediminas Technical University, Naugarduko st. 41, 03227, Vilnius, Lithuania
| | - Gediminas Staigvila
- Institute of High Magnetic Fields, Vilnius Gediminas Technical University, Naugarduko st. 41, 03227, Vilnius, Lithuania
| | - Algimantas Paškevičius
- Laboratory of Biodeterioration Research, Nature Research Centre, Akademijos st. 2, 08412, Vilnius, Lithuania
| | - Irutė Girkontaitė
- Department of Immunology, State Research Institute Centre for Innovative Medicine, Santariškių st. 5, 08406, Vilnius, Lithuania
| | - Auksė Zinkevičienė
- Department of Immunology, State Research Institute Centre for Innovative Medicine, Santariškių st. 5, 08406, Vilnius, Lithuania
| | - Svetlana Markovskaja
- Laboratory of Mycology, Nature Research Centre, Žaliųjų ežerų st. 49, 08406, Vilnius, Lithuania
| | - Jurij Novickij
- Institute of High Magnetic Fields, Vilnius Gediminas Technical University, Naugarduko st. 41, 03227, Vilnius, Lithuania
| |
Collapse
|