1
|
An ultrasensitive electrochemical immunosensor based on in-situ growth of CuWO4 nanoparticles on MoS2 and chitosan-gold nanoparticles for cortisol detection. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107434] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
|
2
|
Anik Ü, Timur S. Towards the electrochemical diagnosis of cancer: nanomaterial-based immunosensors and cytosensors. RSC Adv 2016. [DOI: 10.1039/c6ra23686c] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
In this review, nanomaterial based electrochemical biosensors including electrochemical immunosensors and cytosensors towards cancer detection are covered.
Collapse
Affiliation(s)
- Ülkü Anik
- Mugla Sitki Kocman University
- Faculty of Science
- Chemistry Department
- 48000 Mugla
- Turkey
| | - Suna Timur
- Ege University
- Faculty of Science
- Biochemistry Department
- İzmir
- Turkey
| |
Collapse
|
3
|
Roushani M, Valipour A. Voltammetric immunosensor for human chorionic gonadotropin using a glassy carbon electrode modified with silver nanoparticles and a nanocomposite composed of graphene, chitosan and ionic liquid, and using riboflavin as a redox probe. Mikrochim Acta 2015. [DOI: 10.1007/s00604-015-1731-1] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
4
|
Aslan S, Anik Ü. Development of TiO2and Au Nanocomposite Electrode as CEA Immunosensor Transducer. ELECTROANAL 2014. [DOI: 10.1002/elan.201400086] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
5
|
A new electrochemical biosensor for hydrogen peroxide using HRP/AgNPs/cysteamine/p-ABSA/GCE self-assembly modified electrode. KOREAN J CHEM ENG 2012. [DOI: 10.1007/s11814-012-0078-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
6
|
Saha K, Agasti SS, Kim C, Li X, Rotello VM. Gold nanoparticles in chemical and biological sensing. Chem Rev 2012; 112:2739-79. [PMID: 22295941 PMCID: PMC4102386 DOI: 10.1021/cr2001178] [Citation(s) in RCA: 2777] [Impact Index Per Article: 231.4] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Affiliation(s)
- Krishnendu Saha
- Department of Chemistry, University of Massachusetts Amherst, 710 North Pleasant Street, Amherst, MA 01003, USA
| | - Sarit S. Agasti
- Department of Chemistry, University of Massachusetts Amherst, 710 North Pleasant Street, Amherst, MA 01003, USA
| | - Chaekyu Kim
- Department of Chemistry, University of Massachusetts Amherst, 710 North Pleasant Street, Amherst, MA 01003, USA
| | - Xiaoning Li
- Department of Chemistry, University of Massachusetts Amherst, 710 North Pleasant Street, Amherst, MA 01003, USA
| | - Vincent M. Rotello
- Department of Chemistry, University of Massachusetts Amherst, 710 North Pleasant Street, Amherst, MA 01003, USA
| |
Collapse
|
7
|
Kong FY, Xu-Zhu, Xu MT, Xu JJ, Chen HY. Gold nanoparticle/DNA/methylene blue nanocomposites for the ultrasensitive electrochemical detection of carcinoembryonic antigen. Electrochim Acta 2011. [DOI: 10.1016/j.electacta.2011.08.018] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
8
|
A field effect transistor (FET)-based immunosensor for detection of HbA1c and Hb. Biomed Microdevices 2011; 13:345-52. [PMID: 21170592 DOI: 10.1007/s10544-010-9498-y] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
A field effect transistor (FET)-based immunosensor was developed for diabetes monitoring by detecting the concentrations of glycated hemoglobin (HbA1c) and hemoglobin (Hb). This immunosensor consists of a FET-based sensor chip and a disposable extended-gate electrode chip. The sensor chip was fabricated by standard CMOS process and was integrated with signal readout circuit. The disposable electrode chip, fabricated on polyester plastic board by Micro-Electro-Mechanical-Systems (MEMS) technique, was integrated with electrodes array and micro reaction pool. Biomolecules were immobilized on the electrode based on self-assembled monolayer and gold nanoparticles. Experimental results showed that the immunosensor achieved a linear response to HbA1c with the concentration from 4 to 24 μg/ml, and a linear response to Hb with the concentration from 60 to 180 μg/ml.
Collapse
|
9
|
Arya SK, Bhansali S. Lung Cancer and Its Early Detection Using Biomarker-Based Biosensors. Chem Rev 2011; 111:6783-809. [DOI: 10.1021/cr100420s] [Citation(s) in RCA: 196] [Impact Index Per Article: 15.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Affiliation(s)
- Sunil K. Arya
- Bio-MEMS and Microsystem Lab, Department of Electrical Engineering, University of South Florida, 4202 East Fowler Avenue, ENB 118, Tampa, Florida 33620, United States
| | - Shekhar Bhansali
- Bio-MEMS and Microsystem Lab, Department of Electrical Engineering, University of South Florida, 4202 East Fowler Avenue, ENB 118, Tampa, Florida 33620, United States
| |
Collapse
|
10
|
Cao Y, Yuan R, Chai Y, Mao L, Yang X, Yuan S, Yuan Y, Liao Y. A Solid-State Electrochemiluminescence Immunosensor Based on MWCNTs-Nafion and Ru(bpy)32+/Nano-Pt Nanocomposites for Detection of α-Fetoprotein. ELECTROANAL 2011. [DOI: 10.1002/elan.201000611] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
11
|
Kalachar HCB, S. Basavanna, Viswanatha R, Naik YA, Raj DA, Sudha PN. Electrochemical Determination of L-Dopa in Mucuna pruriens Seeds, Leaves and Commercial Siddha Product Using Gold Modified Pencil Graphite Electrode. ELECTROANAL 2011. [DOI: 10.1002/elan.201000558] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
12
|
Liao Y, Yuan R, Chai Y, Zhuo Y, Yang X. Study on an amperometric immunosensor based on Nafion–cysteine composite membrane for detection of carcinoembryonic antigen. Anal Biochem 2010; 402:47-53. [DOI: 10.1016/j.ab.2010.03.015] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2009] [Revised: 03/09/2010] [Accepted: 03/09/2010] [Indexed: 10/19/2022]
|
13
|
Labib M, Hedström M, Amin M, Mattiasson B. A novel competitive capacitive glucose biosensor based on concanavalin A-labeled nanogold colloids assembled on a polytyramine-modified gold electrode. Anal Chim Acta 2010; 659:194-200. [DOI: 10.1016/j.aca.2009.11.028] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2009] [Revised: 11/09/2009] [Accepted: 11/11/2009] [Indexed: 10/20/2022]
|
14
|
A disposable electrochemical immunosensor for carcinoembryonic antigen based on nano-Au/multi-walled carbon nanotubes–chitosans nanocomposite film modified glassy carbon electrode. Anal Chim Acta 2010; 659:102-8. [DOI: 10.1016/j.aca.2009.11.023] [Citation(s) in RCA: 212] [Impact Index Per Article: 15.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2009] [Revised: 11/09/2009] [Accepted: 11/11/2009] [Indexed: 01/04/2023]
|
15
|
Sharma MK, Agarwal GS, Rao VK, Upadhyay S, Merwyn S, Gopalan N, Rai GP, Vijayaraghavan R, Prakash S. Amperometric immunosensor based on gold nanoparticles/alumina sol–gel modified screen-printed electrodes for antibodies to Plasmodium falciparum histidine rich protein-2. Analyst 2010; 135:608-14. [DOI: 10.1039/b918880k] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
16
|
Oliveira MDL, Correia MTS, Diniz FB. Concanavalin A and polyvinyl butyral use as a potential dengue electrochemical biosensor. Biosens Bioelectron 2009; 25:728-32. [PMID: 19747814 DOI: 10.1016/j.bios.2009.08.009] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2009] [Revised: 07/14/2009] [Accepted: 08/10/2009] [Indexed: 10/20/2022]
Abstract
Immobilization of concanavalin A on gold electrode by means of gold nanoparticles and polyvinyl butyral was carried out and investigated by cyclic voltammetry and electrochemical impedance spectroscopy. The system was tested with sera from patients infected by dengue fever (DF) and dengue hemorrhagic fever (DHF). Electrochemical impedance spectroscopy (in the frequency range from 100mHz to 100KHz), and cyclic voltammetry (from -0.2 to 0.7V vs. Ag/AgCl), was performed in phosphate buffer solution containing 10mM K(3)[Fe(CN)(6)]/K(4)[Fe(CN)(6)] (1:1) mixture as a redox probe. As biomolecules accumulated on the electrode surface the voltammetric response changed from a clear diffusional to an irreversible behavior. Impedance spectroscopy showed a clear increase of the electron-transfer resistance when the sensor is exposed to contaminated sera (DF or DHF) as compared to exposure to uncontaminated serum (NDF). The results were analyzed through an equivalent circuit and values of charge transfer resistance and capacitance were obtained. Variations in charge transfer resistance were used to distinguish the sensor response for the different sera investigated (DF, DHF and NDF). Alternatively, a three-dimensional graph gave the best response for differentiation of all three blood sera. The distinctive patterns of impedimetric responses observed were ascribed to different glycoprotein patterns in the sera investigated. Therefore, the lectin immobilization on electrode surface with gold nanoparticles and polyvinyl butyral, combined with the three-dimensional impedance analysis introduced herein are valuable tools in the development of a biosensor for immunological response to diseases.
Collapse
Affiliation(s)
- Maria D L Oliveira
- Departamento de Química Fundamental, Universidade Federal de Pernambuco, Cidade Universitária 50670-901 Recife, PE, Brazil
| | | | | |
Collapse
|
17
|
Liu H, Yang Y, Chen P, Zhong Z. Enhanced conductometric immunoassay for hepatitis B surface antigen using double-codified nanogold particles as labels. Biochem Eng J 2009. [DOI: 10.1016/j.bej.2009.03.002] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
18
|
Yang GJ, Huang JL, Meng WJ, Shen M, Jiao XA. A reusable capacitive immunosensor for detection of Salmonella spp. based on grafted ethylene diamine and self-assembled gold nanoparticle monolayers. Anal Chim Acta 2009; 647:159-66. [PMID: 19591700 DOI: 10.1016/j.aca.2009.06.008] [Citation(s) in RCA: 92] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2009] [Revised: 05/31/2009] [Accepted: 06/03/2009] [Indexed: 11/27/2022]
Abstract
Fabrication of a novel capacitive immunosensor based on grafted ethylene diamine and self-assembled gold nanoparticle monolayer on glassy carbon electrode for the detection of Salmonella spp. is described for the first time. In the present study, the Salmonella spp. monoclonal antibodies (denoted as McAbs) was immobilized on gold nanoparticles. Interaction of McAbs and Salmonella spp. was detected directly using the electrochemical impedance spectroscopy (EIS) technique. The experimental results showed that the concentration of antigen was measured through the relative change in capacitance in the corresponding specific binding of Salmonella spp. and McAbs. Under the optimized conditions, the relative changes in capacitance were proportional to the logarithmic values of Salmonella spp. concentrations in the range of 1.0 x 10(2) to 1.0 x 10(5) CFU mL(-1) (r = 0.991) with the detection limit of 1.0 x 10(2) CFU mL(-1). The stability of proposed immunosensor could be estimated by determining the relative change in capacitance, which remained almost the same in two months and decreased gradually to 85.3% of initial value after four months' storage. The used immunosensor could be regenerated repeatedly by immersing in glycine-HCl buffer solution (pH 2.8). Finally, the proposed immunosensor was successfully used for the detection of Salmonella spp. in lab-processed commercial pork samples.
Collapse
Affiliation(s)
- Gong-Jun Yang
- College of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, PR China.
| | | | | | | | | |
Collapse
|
19
|
Oliveira MD, Correia MT, Coelho LC, Diniz FB. Electrochemical evaluation of lectin–sugar interaction on gold electrode modified with colloidal gold and polyvinyl butyral. Colloids Surf B Biointerfaces 2008; 66:13-9. [DOI: 10.1016/j.colsurfb.2008.05.002] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2008] [Revised: 04/14/2008] [Accepted: 05/08/2008] [Indexed: 11/26/2022]
|
20
|
Over-the-Counter Biosensors: Past, Present, and Future. SENSORS 2008; 8:5535-5559. [PMID: 27873829 PMCID: PMC3705519 DOI: 10.3390/s8095535] [Citation(s) in RCA: 100] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/19/2008] [Revised: 08/28/2008] [Accepted: 09/03/2008] [Indexed: 11/17/2022]
Abstract
The demand for specific, low cost, rapid, sensitive and easy detection of biomolecules is huge. A well-known example is the glucose meters used by diabetics to monitor their blood glucose levels. Nowadays, a vast majority of the glucose meters are based on electrochemical biosensor technology. The inherent small size and simple construction of the electrochemical transducer and instrument are ideally suited for point-of-care biosensing. Besides glucose, a wide variety of electrochemical biosensors have been developed for the measurements of some other key metabolites, proteins, and nucleic acids. Nevertheless, unlike the glucose meters, limited success has been achieved for the commercialization of the protein and nucleic acid biosensors. In this review article, key technologies on the electrochemical detection of key metabolites, proteins, and DNAs are discussed in detail, with particular emphasis on those that are compatible to home-use setting. Moreover, emerging technologies of lab-on-a-chip microdevices and nanosensors (i.e., silicon and carbon nanotube field-effect sensors) offer opportunities for the construction of new generation biosensors with much better performances. Together with the continuous innovations in the basic components of biosensors (i.e., transducers, biorecognition molecules, immobilization and signal transduction schemes), consumers could soon buy different kinds of biosensing devices in the pharmacy stores.
Collapse
|
21
|
Pingarrón JM, Yáñez-Sedeño P, González-Cortés A. Gold nanoparticle-based electrochemical biosensors. Electrochim Acta 2008. [DOI: 10.1016/j.electacta.2008.03.005] [Citation(s) in RCA: 749] [Impact Index Per Article: 46.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
22
|
Evtugyn G, Porfireva A, Hianik T, Cheburova M, Budnikov H. Potentiometric DNA Sensor Based on Electropolymerized Phenothiazines for Protein Detection. ELECTROANAL 2008. [DOI: 10.1002/elan.200704186] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
23
|
Miao X, Yuan R, Chai Y, Shi Y, Yuan Y. Electrochemical immunoassay for α-1-fetoprotein based on CdS nanoparticles and Thionine bilayer films modified glass carbon electrode. Biochem Eng J 2008. [DOI: 10.1016/j.bej.2007.05.015] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
24
|
Liang WB, Yuan R, Chai YQ, Li Y, Zhuo Y. A novel label-free voltammetric immunosensor for the detection of α-fetoprotein using functional titanium dioxide nanoparticles. Electrochim Acta 2008. [DOI: 10.1016/j.electacta.2007.09.057] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
25
|
Yang G, Yuan R, Chai YQ. A high-sensitive amperometric hydrogen peroxide biosensor based on the immobilization of hemoglobin on gold colloid/l-cysteine/gold colloid/nanoparticles Pt–chitosan composite film-modified platinum disk electrode. Colloids Surf B Biointerfaces 2008; 61:93-100. [PMID: 17855061 DOI: 10.1016/j.colsurfb.2007.07.014] [Citation(s) in RCA: 62] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2007] [Revised: 07/09/2007] [Accepted: 07/24/2007] [Indexed: 11/22/2022]
Abstract
A hemoglobin (Hb)/gold colloid (nano-Au)/L-cysteine (L-cys)/nano-Au/nanoparticles Pt (nano-Pt)-chitosan (CHIT) composite film-modified platinum disk electrode (abbreviated to modified electrode) has been prepared to construct a biosensor for determination of H(2)O(2). The electrochemical characteristics of the biosensor were studied by cyclic voltammetry and chronoamperometry. The modified process was characterized by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). The morphologies of different composite film were investigated with scanning electron microscopy (SEM) and the element of composite film was investigated with X-ray photoelectron spectroscopy (XPS). Analytical parameters such as pH and temperature were also studied. The linear range for the determination of H(2)O(2) is 1.4 x 10(-7) to 6.6 x 10(-3)mol/L with a detection limit of 4.5 x 10(-8)mol/L (S/N=3). The sensor achieved 95% of the steady-state current within 10s. The sensor exhibited high sensitivity (17.62 microA/(mmol L)), selectivity and stability. The method is applied to the determination of H(2)O(2) with satisfactory results.
Collapse
Affiliation(s)
- Gan Yang
- Chongqing Key Laboratory of Analytical Chemistry, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, China
| | | | | |
Collapse
|
26
|
Limbut W, Hedström M, Thavarungkul P, Kanatharana P, Mattiasson B. Capacitive biosensor for detection of endotoxin. Anal Bioanal Chem 2007; 389:517-25. [PMID: 17915336 DOI: 10.1007/s00216-007-1443-4] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
A capacitive biosensor for the detection of bacterial endotoxin has been developed. Endotoxin-neutralizing protein derived from American horseshoe crab was immobilized to a self-assembled thiol layer on a biosensor transducer (Au). Upon injection of a sample containing endotoxin, a decrease in the observed capacitive signal was registered. Endotoxin could be determined under optimum conditions with a detection limit of 1.0 x 10(-13) M and linearity ranging from 1.0 x 10(-13) to 1.0 x 10(-10) M. Good agreement was achieved when applying endotoxin preparations purified from an Escherichia coli cultivation to the capacitive biosensor system, utilizing the conventional method for quantitative endotoxin determination, the Limulus amebocyte lysate test as a reference. The capacitive biosensor method was statistically tested with the Wilcoxon signed rank test, which proved the system is acceptable for the quantitative analysis of bacterial endotoxin (P<0.05).
Collapse
Affiliation(s)
- Warakorn Limbut
- Department of Biotechnology, Center for Chemistry and Chemical Engineering, Lund University, Box 124, 221 00, Lund, Sweden
| | | | | | | | | |
Collapse
|
27
|
Pan J. Voltammetric detection of DNA hybridization using a non-competitive enzyme linked assay. Biochem Eng J 2007. [DOI: 10.1016/j.bej.2007.01.012] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
28
|
Gao F, Yuan R, Chai Y, Tang M, Cao S, Chen S. Amperometric third-generation hydrogen peroxide biosensor based on immobilization of Hb on gold nanoparticles/cysteine/poly(p-aminobenzene sulfonic acid)-modified platinum disk electrode. Colloids Surf A Physicochem Eng Asp 2007. [DOI: 10.1016/j.colsurfa.2006.09.006] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
29
|
Gao F, Yuan R, Chai Y, Chen S, Cao S, Tang M. Amperometric hydrogen peroxide biosensor based on the immobilization of HRP on nano-Au/Thi/poly (p-aminobenzene sulfonic acid)-modified glassy carbon electrode. ACTA ACUST UNITED AC 2006; 70:407-13. [PMID: 17081615 DOI: 10.1016/j.jbbm.2006.09.007] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2006] [Revised: 08/10/2006] [Accepted: 09/17/2006] [Indexed: 02/03/2023]
Abstract
A novel hydrogen peroxide biosensor was fabricated for the determination of H(2)O(2). The precursor film was first electropolymerized on the glassy carbon electrode with p-aminobenzene sulfonic acid (p-ABSA) by cyclic voltammetry (CV). Then thionine (Thi) was adsorbed to the film to form a composite membrane, which yielded an interface containing amine groups to assemble gold nanoparticles (nano-Au) layer for immobilization of horseradish peroxidase (HRP). The electrochemical characteristics of the biosensor were studied by CV and chronoamperometry. The factors influencing the performance of the resulting biosensor were studied in detail. The biosensor responded to H(2)O(2) in the linear range from 2.6 x 10(-6) mol/L to 8.8 x 10(-3) mol/L with a detection limit of 6.4 x 10(-7) mol/L. Moreover, the studied biosensor exhibited good accuracy and high sensitivity. The proposed method was economical and efficient, making it potentially attractive for the application to real sample analysis.
Collapse
Affiliation(s)
- Fengxian Gao
- Chongqing Key Laboratory of Analytical Chemistry, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, China
| | | | | | | | | | | |
Collapse
|
30
|
Limbut W, Kanatharana P, Mattiasson B, Asawatreratanakul P, Thavarungkul P. A comparative study of capacitive immunosensors based on self-assembled monolayers formed from thiourea, thioctic acid, and 3-mercaptopropionic acid. Biosens Bioelectron 2006; 22:233-40. [PMID: 16460923 DOI: 10.1016/j.bios.2005.12.025] [Citation(s) in RCA: 87] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2005] [Revised: 12/13/2005] [Accepted: 12/20/2005] [Indexed: 10/25/2022]
Abstract
A procedure was developed for the covalent coupling of anti-alpha-fetoprotein antibody (anti-AFP) to a gold surface modified with a self-assembled monolayer (SAM) of thiourea (TU). The performance of the SAM-antibody layer was compared to those of similar layers based on thioctic acid (TA) and 3-mercaptopropionic acid (MPA) by using flow injection capacitive immunosensor system. Covalent coupling of anti-AFP on self-assembled thiourea monolayer (SATUM) modified gold electrode can be used to detect alpha-fetoprotein with high efficiency, similar sensitivity, the same linear range (0.01-10 microgl(-1)) and detection limit (10 ngl(-1)) as those obtained from sensors based on self-assembled thioctic acid monolayer (SATAM) and self-assembled 3-mercaptopropionic acid monolayer (SAMPAM). The system is specific for alpha-fetoprotein and can be regenerated and reused up to 48 times. Therefore, self-assembled monolayer using thiourea which is cheaper than thioctic acid and 3-mercaptopropionic acid is a good alternative for biosensor applications when SAMs are used.
Collapse
Affiliation(s)
- Warakorn Limbut
- Biophysics Research Unit, Biosensors and Biocurrents, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand
| | | | | | | | | |
Collapse
|
31
|
Wu J, Tang J, Dai Z, Yan F, Ju H, El Murr N. A disposable electrochemical immunosensor for flow injection immunoassay of carcinoembryonic antigen. Biosens Bioelectron 2006; 22:102-8. [PMID: 16427775 DOI: 10.1016/j.bios.2005.12.008] [Citation(s) in RCA: 154] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2005] [Revised: 11/23/2005] [Accepted: 12/13/2005] [Indexed: 11/16/2022]
Abstract
A new simple immunoassay method for carcinoembryonic antigen (CEA) detection using a disposable immunosensor coupled with a flow injection system was developed. The immunosensor was prepared by coating CEA/colloid Au/chitosan membrane at a screen-printed carbon electrode (SPCE). Using a competitive immunoassay format, the immunosensor inserted in the flow system with an injection of sample and horseradish peroxidase (HRP)-labeled CEA antibody was used to trap the labeled antibody at room temperature for 35 min. The current response obtained from the labeled HRP to thionine-H(2)O(2) system decreased proportionally to the CEA concentration in the range of 0.50-25 ng/ml with a correlation coefficient of 0.9981 and a detection limit of 0.22 ng/ml (S/N=3). The immunoassay system could automatically control the incubation, washing and current measurement steps with good stability and acceptable accuracy. Thus, the proposed method proved its potential use in clinical immunoassay of CEA.
Collapse
Affiliation(s)
- Jie Wu
- Key Laboratory of Analytical Chemistry for Life Science (Education Ministry of China), Department of Chemistry, Nanjing University, Nanjing 210093, PR China
| | | | | | | | | | | |
Collapse
|
32
|
Limbut W, Kanatharana P, Mattiasson B, Asawatreratanakul P, Thavarungkul P. A reusable capacitive immunosensor for carcinoembryonic antigen (CEA) detection using thiourea modified gold electrode. Anal Chim Acta 2006. [DOI: 10.1016/j.aca.2006.01.021] [Citation(s) in RCA: 69] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
33
|
Xu YY, Bian C, Chen S, Xia S. A microelectronic technology based amperometric immunosensor for α-fetoprotein using mixed self-assembled monolayers and gold nanoparticles. Anal Chim Acta 2006. [DOI: 10.1016/j.aca.2005.12.061] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
34
|
Zhuo Y, Yuan R, Chai Y, Zhang Y, Li XL, Zhu Q, Wang N. An amperometric immunosensor based on immobilization of hepatitis B surface antibody on gold electrode modified gold nanoparticles and horseradish peroxidase. Anal Chim Acta 2005. [DOI: 10.1016/j.aca.2005.05.058] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
35
|
|
36
|
A reagentless amperometric immunosensor based on gold nanoparticles/thionine/Nafion-membrane-modified gold electrode for determination of α-1-fetoprotein. Electrochem commun 2005. [DOI: 10.1016/j.elecom.2005.02.001] [Citation(s) in RCA: 106] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
|