1
|
Herzog P, Rendenbach C, Turostowski M, Ellinghaus A, Prates Soares A, Heiland M, Duda GN, Schmidt-Bleek K, Fischer H. Titanium versus plasma electrolytic oxidation surface-modified magnesium miniplates in a forehead secondary fracture healing model in sheep. Acta Biomater 2024; 185:98-110. [PMID: 39002920 DOI: 10.1016/j.actbio.2024.07.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2024] [Revised: 07/02/2024] [Accepted: 07/05/2024] [Indexed: 07/15/2024]
Abstract
Magnesium as a biodegradable material offers promising results in recent studies of different maxillo-facial fracture models. To overcome adverse effects caused by the fast corrosion of pure magnesium in fluid surroundings, various alloys, and surface modifications are tested in animal models. In specified cases, magnesium screws already appeared for clinical use in maxillofacial surgery. The present study aims to compare the bone healing outcome in a non-load-bearing fracture scenario of the forehead in sheep when fixed with standard-sized WE43 magnesium fixation plates and screws with plasma electrolytic oxidation (PEO) surface modification in contrast to titanium osteosynthesis. Surgery was performed on 24 merino mix sheep. The plates and screws were explanted en-bloc with the surrounding tissue after four and twelve weeks. The outcome of bone healing was investigated with micro-computed tomography, histological, immunohistological, and fluorescence analysis. There was no significant difference between groups concerning the bone volume, bone volume/ total volume, and newly formed bone in volumetric and histological analysis at both times of investigation. The fluorescence analysis revealed a significantly lower signal in the magnesium group after one week, although there was no difference in the number of osteoclasts per mm2. The magnesium group had significantly fewer vessels per mm2 in the healing tissue. In conclusion, the non-inferiority of WE43-based magnesium implants with PEO surface modification was verified concerning fracture healing under non-load-bearing conditions in a defect model. STATEMENT OF SIGNIFICANCE: Titanium implants, the current gold standard of fracture fixation, can lead to adverse effects linked to the implant material and often require surgical removal. Therefore, degradable metals like the magnesium alloy WE43 with plasma electrolytic oxidation (PEO) surface modification gained interest. Yet, miniplates of this alloy with PEO surface modification have not been examined in a fracture defect model of the facial skeleton in a large animal model. This study shows, for the first time, the non-inferiority of magnesium miniplates compared to titanium miniplates. In radiological and histological analysis, bone healing was undisturbed. Magnesium miniplates can reduce the number of interventions for implant removal, thus reducing the risk for the patient and minimizing the costs.
Collapse
Affiliation(s)
- Paulina Herzog
- Charité - Universitätsmedizin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Department of Oral and Maxillofacial Surgery, Augustenburger Platz 1, 13353 Berlin, Germany.
| | - Carsten Rendenbach
- Charité - Universitätsmedizin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Department of Oral and Maxillofacial Surgery, Augustenburger Platz 1, 13353 Berlin, Germany.
| | - Marta Turostowski
- Charité - Universitätsmedizin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Department of Oral and Maxillofacial Surgery, Augustenburger Platz 1, 13353 Berlin, Germany
| | - Agnes Ellinghaus
- Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Julius Wolff Institute, Augustenburger Platz 1, 13353 Berlin, Germany
| | - Ana Prates Soares
- Charité - Universitätsmedizin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Department of Oral and Maxillofacial Surgery, Augustenburger Platz 1, 13353 Berlin, Germany; Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Julius Wolff Institute, Augustenburger Platz 1, 13353 Berlin, Germany
| | - Max Heiland
- Charité - Universitätsmedizin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Department of Oral and Maxillofacial Surgery, Augustenburger Platz 1, 13353 Berlin, Germany
| | - Georg N Duda
- Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Julius Wolff Institute, Augustenburger Platz 1, 13353 Berlin, Germany
| | - Katharina Schmidt-Bleek
- Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Julius Wolff Institute, Augustenburger Platz 1, 13353 Berlin, Germany
| | - Heilwig Fischer
- Charité - Universitätsmedizin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Department of Oral and Maxillofacial Surgery, Augustenburger Platz 1, 13353 Berlin, Germany; Charité - Universitätsmedizin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Center for Musculoskeletal Surgery, Augustenburger Platz 1, 13353 Berlin, Germany; Berlin Institute of Health at Charité -Universitätsmedizin Berlin, BIH Biomedical Innovation Academy, BIH Charité Clinician Scientist Program, Charitéplatz 1, 10117 Berlin, Germany
| |
Collapse
|
2
|
Ali W, Ordoño J, Kopp A, González C, Echeverry-Rendón M, LLorca J. Cytocompatibility, cell-material interaction, and osteogenic differentiation of MC3T3-E1 pre-osteoblasts in contact with engineered Mg/PLA composites. J Biomed Mater Res A 2024. [PMID: 38899796 DOI: 10.1002/jbm.a.37767] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2024] [Revised: 05/29/2024] [Accepted: 06/12/2024] [Indexed: 06/21/2024]
Abstract
Bioabsorbable Mg wire-reinforced poly-lactic acid (PLA) matrix composites are potential candidate for load-bearing orthopedic implants offering tailorable mechanical and degradation properties by stacking sequence, volume fraction and surface modification of Mg wires. In this study, we investigated the cytocompatibility, cell-material interaction, and bone differentiation behavior of MC3T3-E1 pre-osteoblast cells for medical-grade PLA, Mg/PLA, and PEO-Mg/PLA (having PEO surface modification on Mg wires) composites. MTT and live/dead assay showed excellent biocompatibility of both composites while cell-material interaction analysis revealed that cells were able to adhere and proliferate on the surface of composites. Cells on the longitudinal surface of composites showed a high and uniform cell density while those on transversal surfaces initially avoided Mg regions but later migrated back after the formation of the passivation layer. Bone differentiation tests showed that cells in extracts of PLA and composites were able to initiate the differentiation process as osteogenesis-related gene expressions, alkaline phosphatase protein quantity, and calcium mineralization increased after 7 and 14 days of culture. Interestingly, the bone differentiation response of PEO-Mg/PLA composite was found to be similar to medical-grade PLA, proving its superiority over Mg/PLA composite.
Collapse
Affiliation(s)
- Wahaaj Ali
- IMDEA Materials Institute, Getafe, Madrid, Spain
- Department of Material Science and Engineering, Universidad Carlos III de Madrid, Leganés, Madrid, Spain
| | - Jesus Ordoño
- IMDEA Materials Institute, Getafe, Madrid, Spain
| | | | - Carlos González
- IMDEA Materials Institute, Getafe, Madrid, Spain
- Department of Materials Science, Polytechnic University of Madrid/Universidad Politécnica de Madrid, Madrid, Spain
| | | | - Javier LLorca
- IMDEA Materials Institute, Getafe, Madrid, Spain
- Department of Materials Science, Polytechnic University of Madrid/Universidad Politécnica de Madrid, Madrid, Spain
| |
Collapse
|
3
|
Thompson C, González C, LLorca J. Additively-manufactured Mg wire-reinforced PLDL-matrix composites for biomedical applications. J Mech Behav Biomed Mater 2024; 153:106496. [PMID: 38460456 DOI: 10.1016/j.jmbbm.2024.106496] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Revised: 02/28/2024] [Accepted: 03/01/2024] [Indexed: 03/11/2024]
Abstract
Coupons of a medical grade PLDL polymer matrix uniaxially reinforced with a 15% volume fraction of Mg wires have been manufactured by fused filament fabrication for the first time. Two different types of Mg wires, without and with a surface treatment by plasma electrolytic oxidation were used. Both composite materials were subjected to degradation in phosphate buffer solution over a 3-week period, and their degradation and deformation micromechanisms were analysed in detail. Additionally, the materials were subjected to extensive mechanical testing under various loading conditions, and the interface strength was also analysed. It was found that the presence of the Mg wires improves the mechanical behaviour and accelerates the corrosion rate of the composite with respect that of the polymer matrix and these properties can be further tailored through the surface-modification of Mg wires by plasma electrolytic oxidation. The additive manufacturing strategy presented opens the path to fabricate multimaterial implants and scaffolds with complex shape and tailored properties provided by biodegradable polymers reinforced with either Mg and Zn particles and/or wires.
Collapse
Affiliation(s)
- C Thompson
- IMDEA Materials Institute, C/ Eric Kandel 2, 28906, Getafe, Madrid, Spain; Department of Material Science and Engineering, Universidad Carlos III de Madrid, 28911, Leganés, Madrid, Spain
| | - C González
- IMDEA Materials Institute, C/ Eric Kandel 2, 28906, Getafe, Madrid, Spain; Department of Material Science, Polytechnic University of Madrid, E. T. S. de Ingenieros de Caminos, 28040 Madrid, Spain
| | - J LLorca
- IMDEA Materials Institute, C/ Eric Kandel 2, 28906, Getafe, Madrid, Spain; Department of Material Science, Polytechnic University of Madrid, E. T. S. de Ingenieros de Caminos, 28040 Madrid, Spain.
| |
Collapse
|
4
|
Beraldo CHM, Versteg A, Spinelli A, Scharnagl N, da Conceição TF. Anticorrosive properties of chitosan-derivatives coatings on Mg AZ31 alloy in Hank's Balanced Salt Solution. Int J Biol Macromol 2024; 260:129390. [PMID: 38218288 DOI: 10.1016/j.ijbiomac.2024.129390] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2023] [Revised: 12/12/2023] [Accepted: 01/08/2024] [Indexed: 01/15/2024]
Abstract
This study describes the preparation of chitosan-derivatives coatings on AZ31 Mg alloy for corrosion protection in Hank's Balanced Salt Solution (HBSS). The derivatives were prepared by reacting chitosan with natural aldehydes (vanillin, benzaldehyde and cinnamaldehyde) and the coatings were characterized by means of water contact angle, scanning electron microscopy and swelling essays. The corrosion behavior of the samples was investigated using potentiodynamic polarization, electrochemical impedance spectroscopy and hydrogen evolution essays. All derivatives present superior corrosion protection than neat chitosan and the best performance is observed for the vanillin derivative with the highest modification degree, which present hydrogen evolution rate of 0.05 mL cm-2 day-1, below the tolerance limit for biomedical application, and |Z|max in the order of 104.6 Ω cm2 even after 14 days of exposure to the corrosive solution.
Collapse
Affiliation(s)
| | - Augusto Versteg
- Chemistry Department, Federal University of Santa Catarina, Florianópolis, Santa Catarina 88040-900, Brazil.
| | - Almir Spinelli
- Chemistry Department, Federal University of Santa Catarina, Florianópolis, Santa Catarina 88040-900, Brazil.
| | - Nico Scharnagl
- Helmholtz-Zentrum Hereon GmbH, Institute of Surface Science, Geesthacht 21502, Germany.
| | - Thiago Ferreira da Conceição
- Materials Engineering Department, Federal University of Santa Catarina, Florianópolis, Santa Catarina 88040-900, Brazil; Chemistry Department, Federal University of Santa Catarina, Florianópolis, Santa Catarina 88040-900, Brazil.
| |
Collapse
|
5
|
Sun L, Bai J, Xue F, Yan K. Microstructural and Textural Evolution of Cold-Drawn Mg-Gd Wires during Annealing Treatment. MATERIALS (BASEL, SWITZERLAND) 2024; 17:683. [PMID: 38591526 PMCID: PMC10856558 DOI: 10.3390/ma17030683] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/04/2024] [Revised: 01/26/2024] [Accepted: 01/27/2024] [Indexed: 04/10/2024]
Abstract
In addition to cold drawing, the process of annealing is also essential in the preparation of Mg-4.7 wt%Gd (G4.7) alloy wires. The effect of annealing treatment on the recrystallized microstructure and texture of cold-drawn G4.7 wires was investigated. The results demonstrate that the uniformity and regularity of the recrystallized grains, as well as the annealing texture, impact the follow-up cold drawing performance. When the as-drawn G4.7 wires were annealed at 375 °C, the recrystallized grains were refined, accompanied by uniformity and regularity. Accordingly, the G4.7 wire had a good subsequent drawing deformability, with a maximum accumulative true strain (ATS) of 144%. Additionally, the evolution of the microstructure was consistent with the evolution of the texture. While annealing at a lower temperature (325 °C), the {0002} basal texture of the G4.7 wire was weak, forming the main texture component <101¯0>//DD (the drawing direction). With the increase in temperature, the basal texture was gradually strengthened and the texture component transformed from <101¯0>//DD to a recrystallized texture based on <112¯0>//DD. Even under high-temperature annealing, the G4.7 wire was still affected by the cold-drawn deformation texture and could not fully recover to the as-extruded texture, thus causing a decrease in the subsequent drawing performance.
Collapse
Affiliation(s)
- Liuxia Sun
- School of Arts and Sciences, Shanghai Dianji University, Shanghai 201306, China
| | - Jing Bai
- School of Materials Science and Engineering, Southeast University, Nanjing 211189, China;
| | - Feng Xue
- School of Materials Science and Engineering, Southeast University, Nanjing 211189, China;
| | - Kai Yan
- College of Mechanical Engineering, Yangzhou University, Yangzhou 225127, China;
| |
Collapse
|
6
|
Kovacevic S, Ali W, Martínez-Pañeda E, LLorca J. Phase-field modeling of pitting and mechanically-assisted corrosion of Mg alloys for biomedical applications. Acta Biomater 2023; 164:641-658. [PMID: 37068554 DOI: 10.1016/j.actbio.2023.04.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2022] [Revised: 03/21/2023] [Accepted: 04/07/2023] [Indexed: 04/19/2023]
Abstract
A phase-field model is developed to simulate the corrosion of Mg alloys in body fluids. The model incorporates both Mg dissolution and the transport of Mg ions in solution, naturally predicting the transition from activation-controlled to diffusion-controlled bio-corrosion. In addition to uniform corrosion, the presented framework captures pitting corrosion and accounts for the synergistic effect of aggressive environments and mechanical loading in accelerating corrosion kinetics. The model applies to arbitrary 2D and 3D geometries with no special treatment for the evolution of the corrosion front, which is described using a diffuse interface approach. Experiments are conducted to validate the model and a good agreement is attained against in vitro measurements on Mg wires. The potential of the model to capture mechano-chemical effects during corrosion is demonstrated in case studies considering Mg wires in tension and bioabsorbable coronary Mg stents subjected to mechanical loading. The proposed methodology can be used to assess the in vitro and in vivo service life of Mg-based biomedical devices and optimize the design taking into account the effect of mechanical deformation on the corrosion rate. The model has the potential to advocate further development of Mg alloys as a biodegradable implant material for biomedical applications. STATEMENT OF SIGNIFICANCE: A physically-based model is developed to simulate the corrosion of bioabsorbable metals in environments that resemble biological fluids. The model captures pitting corrosion and incorporates the role of mechanical fields in enhancing the corrosion of bioabsorbable metals. Model predictions are validated against dedicated in vitro corrosion experiments on Mg wires. The potential of the model to capture mechano-chemical effects is demonstrated in representative examples. The simulations show that the presence of mechanical fields leads to the formation of cracks accelerating the failure of Mg wires, whereas pitting severely compromises the structural integrity of coronary Mg stents. This work extends phase-field modeling to bioengineering and provides a mechanistic tool for assessing the service life of bioabsorbable metallic biomedical devices.
Collapse
Affiliation(s)
- Sasa Kovacevic
- Department of Civil and Environmental Engineering, Imperial College London, London SW7 2AZ, UK.
| | - Wahaaj Ali
- IMDEA Materials Institute, C/Eric Kandel 2, Getafe 28906, Madrid, Spain; Department of Material Science and Engineering, Universidad Carlos III de Madrid, Leganes 28911, Madrid, Spain
| | - Emilio Martínez-Pañeda
- Department of Civil and Environmental Engineering, Imperial College London, London SW7 2AZ, UK.
| | - Javier LLorca
- IMDEA Materials Institute, C/Eric Kandel 2, Getafe 28906, Madrid, Spain; Department of Materials Science, Polytechnic University of Madrid, E. T. S. de Ingenieros de Caminos, 28040 Madrid, Spain.
| |
Collapse
|