1
|
Batista Napotnik T, Polajžer T, Miklavčič D. Cell death due to electroporation - A review. Bioelectrochemistry 2021; 141:107871. [PMID: 34147013 DOI: 10.1016/j.bioelechem.2021.107871] [Citation(s) in RCA: 172] [Impact Index Per Article: 57.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Revised: 05/12/2021] [Accepted: 06/03/2021] [Indexed: 12/15/2022]
Abstract
Exposure of cells to high voltage electric pulses increases transiently membrane permeability through membrane electroporation. Electroporation can be reversible and is used in gene transfer and enhanced drug delivery but can also lead to cell death. Electroporation resulting in cell death (termed as irreversible electroporation) has been successfully used as a new non-thermal ablation method of soft tissue such as tumours or arrhythmogenic heart tissue. Even though the mechanisms of cell death can influence the outcome of electroporation-based treatments due to use of different electric pulse parameters and conditions, these are not elucidated yet. We review the mechanisms of cell death after electroporation reported in literature, cell injuries that may lead to cell death after electroporation and membrane repair mechanisms involved. The knowledge of membrane repair and cell death mechanisms after cell exposure to electric pulses, targets of electric field in cells need to be identified to optimize existing and develop of new electroporation-based techniques used in medicine, biotechnology, and food technology.
Collapse
Affiliation(s)
- Tina Batista Napotnik
- University of Ljubljana, Faculty of Electrical Engineering, Tržaška cesta 25, 1000 Ljubljana, Slovenia
| | - Tamara Polajžer
- University of Ljubljana, Faculty of Electrical Engineering, Tržaška cesta 25, 1000 Ljubljana, Slovenia
| | - Damijan Miklavčič
- University of Ljubljana, Faculty of Electrical Engineering, Tržaška cesta 25, 1000 Ljubljana, Slovenia.
| |
Collapse
|
2
|
Yang X, Cheng H. Recent Developments of Flexible and Stretchable Electrochemical Biosensors. MICROMACHINES 2020; 11:E243. [PMID: 32111023 PMCID: PMC7143805 DOI: 10.3390/mi11030243] [Citation(s) in RCA: 39] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/29/2019] [Revised: 02/20/2020] [Accepted: 02/24/2020] [Indexed: 12/14/2022]
Abstract
The skyrocketing popularity of health monitoring has spurred increasing interest in wearable electrochemical biosensors. Compared with the traditionally rigid and bulky electrochemical biosensors, flexible and stretchable devices render a unique capability to conform to the complex, hierarchically textured surfaces of the human body. With a recognition element (e.g., enzymes, antibodies, nucleic acids, ions) to selectively react with the target analyte, wearable electrochemical biosensors can convert the types and concentrations of chemical changes in the body into electrical signals for easy readout. Initial exploration of wearable electrochemical biosensors integrates electrodes on textile and flexible thin-film substrate materials. A stretchable property is needed for the thin-film device to form an intimate contact with the textured skin surface and to deform with various natural skin motions. Thus, stretchable materials and structures have been exploited to ensure the effective function of a wearable electrochemical biosensor. In this mini-review, we summarize the recent development of flexible and stretchable electrochemical biosensors, including their principles, representative application scenarios (e.g., saliva, tear, sweat, and interstitial fluid), and materials and structures. While great strides have been made in the wearable electrochemical biosensors, challenges still exist, which represents a small fraction of opportunities for the future development of this burgeoning field.
Collapse
Affiliation(s)
- Xudong Yang
- Key Laboratory of Optoelectronic Technology & Systems (Ministry of Education), Chongqing University, Chongqing 400044, China;
- Department of Automotive Engineering, Beihang University, Beijing 100191, China
- Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, PA 16802, USA
| | - Huanyu Cheng
- Key Laboratory of Optoelectronic Technology & Systems (Ministry of Education), Chongqing University, Chongqing 400044, China;
- Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, PA 16802, USA
- State Key Laboratory of Digital Manufacturing Equipment and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| |
Collapse
|
3
|
Dastani K, Moghimi Zand M, Kavand H, Javidi R, Hadi A, Valadkhani Z, Renaud P. Effect of input voltage frequency on the distribution of electrical stresses on the cell surface based on single-cell dielectrophoresis analysis. Sci Rep 2020; 10:68. [PMID: 31919394 PMCID: PMC6952456 DOI: 10.1038/s41598-019-56952-4] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2018] [Accepted: 12/19/2019] [Indexed: 11/23/2022] Open
Abstract
Electroporation is defined as cell membrane permeabilization under the application of electric fields. The mechanism of hydrophilic pore formation is not yet well understood. When cells are exposed to electric fields, electrical stresses act on their surfaces. These electrical stresses play a crucial role in cell membrane structural changes, which lead to cell permeabilization. These electrical stresses depend on the dielectric properties of the cell, buffer solution, and the applied electric field characteristics. In the current study, the effect of electric field frequency on the electrical stresses distribution on the cell surface and cell deformation is numerically and experimentally investigated. As previous studies were mostly focused on the effect of electric fields on a group of cells, the present study focused on the behavior of a single cell exposed to an electric field. To accomplish this, the effect of cells on electrostatic potential distribution and electric field must be considered. To do this, Fast immersed interface method (IIM) was used to discretize the governing quasi-electrostatic equations. Numerical results confirmed the accuracy of fast IIM in satisfying the internal electrical boundary conditions on the cell surface. Finally, experimental results showed the effect of applied electric field on cell deformation at different frequencies.
Collapse
Affiliation(s)
- Kia Dastani
- Small Medical Devices, BioMEMS & LoC Lab, School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran, 11155-4563, Iran.,School of Mechanical Engineering, Sharif University of Technology, Tehran, Iran
| | - Mahdi Moghimi Zand
- Small Medical Devices, BioMEMS & LoC Lab, School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran, 11155-4563, Iran.
| | - Hanie Kavand
- École Polytechnique Fédérale de Lausanne, STI IMT LMIS4, Station 17, CH-1015, Lausanne, Switzerland
| | - Reza Javidi
- Small Medical Devices, BioMEMS & LoC Lab, School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran, 11155-4563, Iran
| | - Amin Hadi
- Small Medical Devices, BioMEMS & LoC Lab, School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran, 11155-4563, Iran
| | - Zarrintaj Valadkhani
- Department of Medical Parasitology, Pasteur Institute of Iran, Tehran, Post code: 1316943551, Iran
| | - Philippe Renaud
- École Polytechnique Fédérale de Lausanne, STI IMT LMIS4, Station 17, CH-1015, Lausanne, Switzerland
| |
Collapse
|
4
|
Lim Y, Su CH, Liao YC, Lee SY. Impedimetric analysis on the mass transfer properties of intact and competent E. coli cells. BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES 2018; 1861:9-16. [PMID: 30341999 DOI: 10.1016/j.bbamem.2018.10.010] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/18/2017] [Revised: 10/10/2018] [Accepted: 10/15/2018] [Indexed: 12/31/2022]
Abstract
Competent Escherichia coli cells are commonly used in bacterial transformation owing to its high permeability for bioorganic macromolecules like plasmid DNA. However, the mass transfer property of competent E. coli cell has not fully investigated. In the present study, mass transfer coefficients of competent and intact E. coli cells in deionized water were evaluated by impedimetric analysis of the release of cytoplasmic compounds. Because competent cells have a higher permeability after chemical treatment, the lumped mass transfer coefficient of a competent cell was approximately 6.5 times larger than that of an intact cell at room temperature. Release of cytoplasmic components was accelerated at an elevated temperature of 42 °C, which is the heat shock temperature used during bacterial transformation. At this elevated temperature, assessed lumped mass transfer coefficients of intact and competent E. coli cells were 9.28 × 10-4 min-1 and 97.10 × 10-4 min-1, respectively. Significant increase in the mass transfer coefficient of the competent cell is caused by cytolysis of cells. The double layer capacitances were also assessed from the electrochemical spectra confirming the enhanced ion release from E. coli cells and rupture of the competent cell under prolonged exposure at the elevated temperature. Impedimetric detection of the ion release with analyses using an equivalent circuit model provides a method to evaluate mass transfer properties of biomolecules.
Collapse
Affiliation(s)
- Youngjoon Lim
- Department of Chemical and Biomolecular Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul 03722, Republic of Korea
| | - Chun-Hao Su
- Department of Chemical Engineering, National Taiwan University, No.1 Sec. 4 Roosevelt Road, Taipei 10617, Taiwan
| | - Ying-Chih Liao
- Department of Chemical Engineering, National Taiwan University, No.1 Sec. 4 Roosevelt Road, Taipei 10617, Taiwan.
| | - Sang-Yup Lee
- Department of Chemical and Biomolecular Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul 03722, Republic of Korea.
| |
Collapse
|
5
|
Pasquet L, Bellard E, Rols MP, Golzio M, Teissie J. Post-pulse addition of trans-cyclohexane-1,2-diol improves electrotransfer mediated gene expression in mammalian cells. Biochem Biophys Rep 2016; 7:287-294. [PMID: 28955917 PMCID: PMC5613639 DOI: 10.1016/j.bbrep.2016.07.012] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2016] [Revised: 07/08/2016] [Accepted: 07/14/2016] [Indexed: 12/17/2022] Open
Abstract
Electric field mediated gene transfer is facing a problem in expression yield due to the poor transfer across the nuclear envelope. Trans-cyclohexane-1,2-diol (TCHD) was shown to significantly increase chemically mediated transfection by collapsing the permeability barrier of the nuclear pore complex. We indeed observed a significant increase in expression by electrotransfer when cells are treated post pulse by a low non toxic concentration of TCHD. This was obtained for different pulsing conditions, cell strains and plasmid constructs. An interesting improvement in cell viability can be obtained. This can significantly enhance the non-viral gene electrical delivery. Trans-cyclohexane-1,2-diol (TCHD) collapses the permeability barrier of the nuclear pore complex. TCHD improves expression in gene electrotransfer. Post pulse TCHD addition is the most effective protocol. TCHD does not affect the cell viability when coupled to electrotransfer.
Collapse
Affiliation(s)
- L Pasquet
- Centre National de la Recherche Scientifique, Institut de Pharmacologie et de Biologie Structurale, BP64182, 205 route de Narbonne, F-31077 Toulouse, France.,Centre National de la Recherche Scientifique, Institut de Pharmacologie et de Biologie Structurale, Université de Toulouse, UPS, IPBS, F-31077 Toulouse, France
| | - E Bellard
- Centre National de la Recherche Scientifique, Institut de Pharmacologie et de Biologie Structurale, BP64182, 205 route de Narbonne, F-31077 Toulouse, France.,Centre National de la Recherche Scientifique, Institut de Pharmacologie et de Biologie Structurale, Université de Toulouse, UPS, IPBS, F-31077 Toulouse, France
| | - M P Rols
- Centre National de la Recherche Scientifique, Institut de Pharmacologie et de Biologie Structurale, BP64182, 205 route de Narbonne, F-31077 Toulouse, France.,Centre National de la Recherche Scientifique, Institut de Pharmacologie et de Biologie Structurale, Université de Toulouse, UPS, IPBS, F-31077 Toulouse, France
| | - M Golzio
- Centre National de la Recherche Scientifique, Institut de Pharmacologie et de Biologie Structurale, BP64182, 205 route de Narbonne, F-31077 Toulouse, France.,Centre National de la Recherche Scientifique, Institut de Pharmacologie et de Biologie Structurale, Université de Toulouse, UPS, IPBS, F-31077 Toulouse, France
| | - J Teissie
- Centre National de la Recherche Scientifique, Institut de Pharmacologie et de Biologie Structurale, BP64182, 205 route de Narbonne, F-31077 Toulouse, France.,Centre National de la Recherche Scientifique, Institut de Pharmacologie et de Biologie Structurale, Université de Toulouse, UPS, IPBS, F-31077 Toulouse, France
| |
Collapse
|
6
|
Blumrosen G, Abazari A, Golberg A, Yarmush ML, Toner M. Single-step electrical field strength screening to determine electroporation induced transmembrane transport parameters. BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES 2016; 1858:2041-2049. [PMID: 27263825 DOI: 10.1016/j.bbamem.2016.05.022] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/30/2015] [Revised: 05/04/2016] [Accepted: 05/31/2016] [Indexed: 12/15/2022]
Abstract
The design of effective electroporation protocols for molecular delivery applications requires the determination of transport parameters including diffusion coefficient, membrane resealing, and critical electric field strength for electroporation. The use of existing technologies to determine these parameters is time-consuming and labor-intensive, and often results in large inconsistencies in parameter estimation due to variations in the protocols and setups. In this work, we suggest using a set of concentric electrodes to screen a full range of electric field strengths in a single test to determine the electroporation-induced transmembrane transport parameters. Using Calcein as a fluorescent probe, we developed analytical methodology to determine the transport parameters based on the electroporation-induced pattern of fluorescence loss from cells. A monolayer of normal human dermal fibroblast (NHDF) cells were pre-loaded with Calcein and electroporated with an applied voltage of 750V with 10 and 50 square pulses with 50μs duration. Using our analytical model, the critical electric field strength for electroporation was found for the 10 and 50 pulses experiments. An inverse correlation between the field strength and the molecular transport time decay constant, and a direct correlation between field strength and the membrane permeability were observed. The results of this work can simplify the development of electroporation-assisted technologies for research and therapies.
Collapse
Affiliation(s)
- Gadi Blumrosen
- Department of Computer Science, Tel Aviv University, Israel
| | - Alireza Abazari
- The Center for Engineering in Medicine, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, United States
| | - Alexander Golberg
- The Center for Engineering in Medicine, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, United States; Porter School of Environmental Studies, Tel Aviv University, Israel.
| | - Martin L Yarmush
- The Center for Engineering in Medicine, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, United States; Department of Biomedical Engineering, Rutgers University, Piscataway, NJ 08854., United States.
| | - Mehmet Toner
- The Center for Engineering in Medicine, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, United States
| |
Collapse
|
7
|
García-Sánchez T, Azan A, Leray I, Rosell-Ferrer J, Bragós R, Mir LLM. Interpulse multifrequency electrical impedance measurements during electroporation of adherent differentiated myotubes. Bioelectrochemistry 2015; 105:123-35. [DOI: 10.1016/j.bioelechem.2015.05.018] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2014] [Revised: 05/25/2015] [Accepted: 05/31/2015] [Indexed: 01/26/2023]
|
8
|
Shagoshtasbi H, Deng P, Lee YK. A Nonlinear Size-Dependent Equivalent Circuit Model for Single-Cell Electroporation on Microfluidic Chips. ACTA ACUST UNITED AC 2015; 20:481-90. [DOI: 10.1177/2211068215573189] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2014] [Indexed: 11/16/2022]
|
9
|
Demiryurek Y, Nickaeen M, Zheng M, Yu M, Zahn JD, Shreiber DI, Lin H, Shan JW. Transport, resealing, and re-poration dynamics of two-pulse electroporation-mediated molecular delivery. BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES 2015; 1848:1706-14. [PMID: 25911207 DOI: 10.1016/j.bbamem.2015.04.007] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2014] [Revised: 03/16/2015] [Accepted: 04/14/2015] [Indexed: 01/08/2023]
Abstract
Electroporation is of interest for many drug-delivery and gene-therapy applications. Prior studies have shown that a two-pulse-electroporation protocol consisting of a short-duration, high-voltage first pulse followed by a longer, low-voltage second pulse can increase delivery efficiency and preserve viability. In this work the effects of the field strength of the first and second pulses and the inter-pulse delay time on the delivery of two different-sized Fluorescein-Dextran (FD) conjugates are investigated. A series of two-pulse-electroporation experiments were performed on 3T3-mouse fibroblast cells, with an alternating-current first pulse to permeabilize the cell, followed by a direct-current second pulse. The protocols were rationally designed to best separate the mechanisms of permeabilization and electrophoretic transport. The results showed that the delivery of FD varied strongly with the strength of the first pulse and the size of the target molecule. The delivered FD concentration also decreased linearly with the logarithm of the inter-pulse delay. The data indicate that membrane resealing after electropermeabilization occurs rapidly, but that a non-negligible fraction of the pores can be reopened by the second pulse for delay times on the order of hundreds of seconds. The role of the second pulse is hypothesized to be more than just electrophoresis, with a minimum threshold field strength required to reopen nano-sized pores or defects remaining from the first pulse. These results suggest that membrane electroporation, sealing, and re-poration is a complex process that has both short-term and long-term components, which may in part explain the wide variation in membrane-resealing times reported in the literature.
Collapse
Affiliation(s)
- Yasir Demiryurek
- Department of Mechanical and Aerospace Engineering, Rutgers, The State University of New Jersey, 98 Brett Road, Piscataway, NJ 08854, USA
| | - Masoud Nickaeen
- Department of Mechanical and Aerospace Engineering, Rutgers, The State University of New Jersey, 98 Brett Road, Piscataway, NJ 08854, USA
| | - Mingde Zheng
- Department of Biomedical Engineering, Rutgers, The State University of New Jersey, 599 Taylor Road, Piscataway, NJ 08854, USA
| | - Miao Yu
- Department of Mechanical and Aerospace Engineering, Rutgers, The State University of New Jersey, 98 Brett Road, Piscataway, NJ 08854, USA
| | - Jeffrey D Zahn
- Department of Biomedical Engineering, Rutgers, The State University of New Jersey, 599 Taylor Road, Piscataway, NJ 08854, USA
| | - David I Shreiber
- Department of Biomedical Engineering, Rutgers, The State University of New Jersey, 599 Taylor Road, Piscataway, NJ 08854, USA
| | - Hao Lin
- Department of Mechanical and Aerospace Engineering, Rutgers, The State University of New Jersey, 98 Brett Road, Piscataway, NJ 08854, USA
| | - Jerry W Shan
- Department of Mechanical and Aerospace Engineering, Rutgers, The State University of New Jersey, 98 Brett Road, Piscataway, NJ 08854, USA.
| |
Collapse
|
10
|
Sadik MM, Yu M, Zheng M, Zahn JD, Shan JW, Shreiber DI, Lin H. Scaling relationship and optimization of double-pulse electroporation. Biophys J 2014; 106:801-12. [PMID: 24559983 DOI: 10.1016/j.bpj.2013.12.045] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2013] [Revised: 09/20/2013] [Accepted: 12/31/2013] [Indexed: 02/03/2023] Open
Abstract
The efficacy of electroporation is known to vary significantly across a wide variety of biological research and clinical applications, but as of this writing, a generalized approach to simultaneously improve efficiency and maintain viability has not been available in the literature. To address that discrepancy, we here outline an approach that is based on the mapping of the scaling relationships among electroporation-mediated molecular delivery, cellular viability, and electric pulse parameters. The delivery of Fluorescein-Dextran into 3T3 mouse fibroblast cells was used as a model system. The pulse was rationally split into two sequential phases: a first precursor for permeabilization, followed by a second one for molecular delivery. Extensive data in the parameter space of the second pulse strength and duration were collected and analyzed with flow cytometry. The fluorescence intensity correlated linearly with the second pulse duration, confirming the dominant role of electrophoresis in delivery. The delivery efficiency exhibited a characteristic sigmoidal dependence on the field strength. An examination of short-term cell death using 7-Aminoactinomycin D demonstrated a convincing linear correlation with respect to the electrical energy. Based on these scaling relationships, an optimal field strength becomes identifiable. A model study was also performed, and the results were compared with the experimental data to elucidate underlying mechanisms. The comparison reveals the existence of a critical transmembrane potential above which delivery with the second pulse becomes effective. Together, these efforts establish a general route to enhance the functionality of electroporation.
Collapse
Affiliation(s)
- Mohamed M Sadik
- Department of Mechanical and Aerospace Engineering, Rutgers, The State University of New Jersey, Piscataway, New Jersey
| | - Miao Yu
- Department of Mechanical and Aerospace Engineering, Rutgers, The State University of New Jersey, Piscataway, New Jersey
| | - Mingde Zheng
- Department of Biomedical Engineering, Rutgers, The State University of New Jersey, Piscataway, New Jersey
| | - Jeffrey D Zahn
- Department of Biomedical Engineering, Rutgers, The State University of New Jersey, Piscataway, New Jersey
| | - Jerry W Shan
- Department of Mechanical and Aerospace Engineering, Rutgers, The State University of New Jersey, Piscataway, New Jersey
| | - David I Shreiber
- Department of Biomedical Engineering, Rutgers, The State University of New Jersey, Piscataway, New Jersey
| | - Hao Lin
- Department of Mechanical and Aerospace Engineering, Rutgers, The State University of New Jersey, Piscataway, New Jersey.
| |
Collapse
|
11
|
Ion transport into cells exposed to monopolar and bipolar nanosecond pulses. Bioelectrochemistry 2014; 103:44-51. [PMID: 25212701 DOI: 10.1016/j.bioelechem.2014.08.015] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2014] [Revised: 07/21/2014] [Accepted: 08/12/2014] [Indexed: 02/06/2023]
Abstract
Experiments with CHO cells exposed to 60 and 300 ns pulsed electric fields with amplitudes in the range from several kV/cm to tens of kV/cm showed a decrease of the uptake of calcium ions by more than an order of magnitude when, immediately after a first pulse, a second one of opposite polarity was applied. This effect is assumed to be due to the reversal of the electrophoretic transport of ions through the electroporated membrane during the second phase of the bipolar pulse. This assumption, however, is only valid if electrophoresis is the dominant transport mechanism, rather than diffusion. Comparison of calculated calcium ion currents with experimental results showed that for nanosecond pulses, electrophoresis is at least as important as diffusion. By delaying the second pulse with respect to the first one, the effect of reverse electrophoresis is reduced. Consequently, separating nanosecond pulses of opposite polarity by up to approximately hundred microseconds allows us to vary the uptake of ions from very small values to those obtained with two pulses of the same polarity. The measured calcium ion uptake obtained with bipolar pulses also allowed us to determine the membrane pore recovery time. The calculated recovery time constants are on the order of 10 μs.
Collapse
|
12
|
García-Sánchez T, Guitart M, Rosell-Ferrer J, Gómez-Foix AM, Bragós R. A new spiral microelectrode assembly for electroporation and impedance measurements of adherent cell monolayers. Biomed Microdevices 2014; 16:575-90. [DOI: 10.1007/s10544-014-9860-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
|
13
|
Abstract
Electroporation is a simple yet powerful technique for breaching the cell membrane barrier. The applications of electroporation can be generally divided into two categories: the release of intracellular proteins, nucleic acids and other metabolites for analysis and the delivery of exogenous reagents such as genes, drugs and nanoparticles with therapeutic purposes or for cellular manipulation. In this review, we go over the basic physics associated with cell electroporation and highlight recent technological advances on microfluidic platforms for conducting electroporation. Within the context of its working mechanism, we summarize the accumulated knowledge on how the parameters of electroporation affect its performance for various tasks. We discuss various strategies and designs for conducting electroporation at the microscale and then focus on analysis of intracellular contents and delivery of exogenous agents as two major applications of the technique. Finally, an outlook for future applications of microfluidic electroporation in increasingly diverse utilities is presented.
Collapse
Affiliation(s)
- Tao Geng
- Department of Agricultural and Biological Engineering, Purdue University, West Lafayette, IN 47907, USA
| | - Chang Lu
- Department of Chemical Engineering, Virginia Tech, Blacksburg, VA 24061, USA. Fax: +1-540-231-5022; Tel: +1-540-231-8681
- School of Biomedical Engineering and Sciences, Virginia Tech-Wake Forest University, Blacksburg, VA 24061, USA
| |
Collapse
|
14
|
Meacham JM, Durvasula K, Degertekin FL, Fedorov AG. Physical methods for intracellular delivery: practical aspects from laboratory use to industrial-scale processing. ACTA ACUST UNITED AC 2013; 19:1-18. [PMID: 23813915 DOI: 10.1177/2211068213494388] [Citation(s) in RCA: 67] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Effective intracellular delivery is a significant impediment to research and therapeutic applications at all processing scales. Physical delivery methods have long demonstrated the ability to deliver cargo molecules directly to the cytoplasm or nucleus, and the mechanisms underlying the most common approaches (microinjection, electroporation, and sonoporation) have been extensively investigated. In this review, we discuss established approaches, as well as emerging techniques (magnetofection, optoinjection, and combined modalities). In addition to operating principles and implementation strategies, we address applicability and limitations of various in vitro, ex vivo, and in vivo platforms. Importantly, we perform critical assessments regarding (1) treatment efficacy with diverse cell types and delivered cargo molecules, (2) suitability to different processing scales (from single cell to large populations), (3) suitability for automation/integration with existing workflows, and (4) multiplexing potential and flexibility/adaptability to enable rapid changeover between treatments of varied cell types. Existing techniques typically fall short in one or more of these criteria; however, introduction of micro-/nanotechnology concepts, as well as synergistic coupling of complementary method(s), can improve performance and applicability of a particular approach, overcoming barriers to practical implementation. For this reason, we emphasize these strategies in examining recent advances in development of delivery systems.
Collapse
|
15
|
Ramos A, Schneider ALS, Suzuki DOH, Marques LB. Sinusoidal Signal Analysis of Electroporation in Biological Cells. IEEE Trans Biomed Eng 2012; 59:2965-73. [DOI: 10.1109/tbme.2012.2212896] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
16
|
Lin R, Chang DC, Lee YK. Single-cell electroendocytosis on a micro chip using in situ fluorescence microscopy. Biomed Microdevices 2011; 13:1063-73. [DOI: 10.1007/s10544-011-9576-9] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
17
|
Smith KC, Weaver JC. Transmembrane molecular transport during versus after extremely large, nanosecond electric pulses. Biochem Biophys Res Commun 2011; 412:8-12. [PMID: 21756883 DOI: 10.1016/j.bbrc.2011.06.171] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2011] [Accepted: 06/25/2011] [Indexed: 11/16/2022]
Abstract
Recently there has been intense and growing interest in the non-thermal biological effects of nanosecond electric pulses, particularly apoptosis induction. These effects have been hypothesized to result from the widespread creation of small, lipidic pores in the plasma and organelle membranes of cells (supra-electroporation) and, more specifically, ionic and molecular transport through these pores. Here we show that transport occurs overwhelmingly after pulsing. First, we show that the electrical drift distance for typical charged solutes during nanosecond pulses (up to 100 ns), even those with very large magnitudes (up to 10 MV/m), ranges from only a fraction of the membrane thickness (5 nm) to several membrane thicknesses. This is much smaller than the diameter of a typical cell (∼16 μm), which implies that molecular drift transport during nanosecond pulses is necessarily minimal. This implication is not dependent on assumptions about pore density or the molecular flux through pores. Second, we show that molecular transport resulting from post-pulse diffusion through minimum-size pores is orders of magnitude larger than electrical drift-driven transport during nanosecond pulses. While field-assisted charge entry and the magnitude of flux favor transport during nanosecond pulses, these effects are too small to overcome the orders of magnitude more time available for post-pulse transport. Therefore, the basic conclusion that essentially all transmembrane molecular transport occurs post-pulse holds across the plausible range of relevant parameters. Our analysis shows that a primary direct consequence of nanosecond electric pulses is the creation (or maintenance) of large populations of small pores in cell membranes that govern post-pulse transmembrane transport of small ions and molecules.
Collapse
Affiliation(s)
- Kyle C Smith
- Harvard-M.I.T. Division of Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | | |
Collapse
|
18
|
Huang H, Wei Z, Huang Y, Zhao D, Zheng L, Cai T, Wu M, Wang W, Ding X, Zhou Z, Du Q, Li Z, Liang Z. An efficient and high-throughput electroporation microchip applicable for siRNA delivery. LAB ON A CHIP 2011; 11:163-172. [PMID: 20957267 DOI: 10.1039/c0lc00195c] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Here we report a novel electroporation microchip with great performance and compatibility with the standard multi-well plate used in biological research. The novel annular interdigitated electrode design makes it possible to achieve efficient cell transfection as high as 90% under low-strength electrical pulses, thereby circumventing the many adverse effects of conventional cuvette-type and previously reported microchip-based electroporation devices. Using this system, we demonstrated substantially improved cell transfection efficacy and viability in cultured and primary cells, for both plasmid and synthetic siRNA. Improvements of this system open new opportunities for high-throughput applications of siRNA technology in basic and biomedical research.
Collapse
Affiliation(s)
- Huang Huang
- Institute of Molecular Medicine, Peking University, Beijing, 100871, China
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
19
|
Kim JA, Lee WG, Jung NC. Enhanced electro-mediated gene delivery using carrier genes. Bioelectrochemistry 2010; 78:186-90. [DOI: 10.1016/j.bioelechem.2009.08.012] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2009] [Revised: 08/26/2009] [Accepted: 08/28/2009] [Indexed: 10/20/2022]
|
20
|
Ben-Or A, Rubinsky B. Experimental Studies on Irreversible Electroporation of Cells. IRREVERSIBLE ELECTROPORATION 2010. [DOI: 10.1007/978-3-642-05420-4_3] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
21
|
Lee WG, Demirci U, Khademhosseini A. Microscale electroporation: challenges and perspectives for clinical applications. Integr Biol (Camb) 2009; 1:242-51. [PMID: 20023735 DOI: 10.1039/b819201d] [Citation(s) in RCA: 93] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
Microscale engineering plays a significant role in developing tools for biological applications by miniaturizing devices and providing controllable microenvironments for in vitro cell research. Miniaturized devices offer numerous benefits in comparison to their macroscale counterparts, such as lower use of expensive reagents, biomimetic environments, and the ability to manipulate single cells. Microscale electroporation is one of the main beneficiaries of microscale engineering as it provides spatial and temporal control of various electrical parameters. Microscale electroporation devices can be used to reduce limitations associated with the conventional electroporation approaches such as variations in the local pH, electric field distortion, sample contamination, and the difficulties in transfecting and maintaining the viability of desired cell types. Here, we present an overview of recent advances of the microscale electroporation methods and their applications in biology, as well as current challenges for its use for clinical applications. We categorize microscale electroporation into microchannel and microcapillary electroporation. Microchannel-based electroporation can be used for transfecting cells within microchannels under dynamic flow conditions in a controlled and high-throughput fashion. In contrast, microcapillary-based electroporation can be used for transfecting cells within controlled reaction chambers under static flow conditions. Using these categories we examine the use of microscale electroporation for clinical applications related to HIV-1, stem cells, cancer and other diseases and discuss the challenges in further advancing this technology for use in clinical medicine and biology.
Collapse
Affiliation(s)
- Won Gu Lee
- Center for Biomedical Engineering, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA.
| | | | | |
Collapse
|