1
|
Prygiel M, Mosiej E, Polak M, Krysztopa-Grzybowska K, Wdowiak K, Formińska K, Zasada AA. Challenges of Diphtheria Toxin Detection. Toxins (Basel) 2024; 16:245. [PMID: 38922140 PMCID: PMC11209151 DOI: 10.3390/toxins16060245] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2024] [Revised: 05/22/2024] [Accepted: 05/24/2024] [Indexed: 06/27/2024] Open
Abstract
Diphtheria toxin (DT) is the main virulence factor of Corynebacterium diphtheriae, C. ulcerans and C. pseudotuberculosis. Moreover, new Corynebacterium species with the potential to produce diphtheria toxin have also been described. Therefore, the detection of the toxin is the most important test in the microbiological diagnosis of diphtheria and other corynebacteria infections. Since the first demonstration in 1888 that DT is a major virulence factor of C. diphtheriae, responsible for the systemic manifestation of the disease, various methods for DT detection have been developed, but the diagnostic usefulness of most of them has not been confirmed on a sufficiently large group of samples. Despite substantial progress in the science and diagnostics of infectious diseases, the Elek test is still the basic recommended diagnostic test for DT detection. The challenge here is the poor availability of an antitoxin and declining experience even in reference laboratories due to the low prevalence of diphtheria in developed countries. However, recent and very promising assays have been developed with the potential for use as rapid point-of-care testing (POCT), such as ICS and LFIA for toxin detection, LAMP for tox gene detection, and biosensors for both.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Aleksandra A. Zasada
- Department of Sera and Vaccines Evaluation, National Institute of Public Health NIH—National Research Institute, Chocimska 24, 00-791 Warsaw, Poland; (M.P.); (E.M.); (M.P.); (K.K.-G.); (K.W.); (K.F.)
| |
Collapse
|
2
|
Kumar P, Anitha A, Das A, Deepalakshmi G, Suman P. Point-of-care impedimetric aptasensor to detect the luteinizing hormone. Mikrochim Acta 2024; 191:115. [PMID: 38286844 DOI: 10.1007/s00604-024-06191-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Accepted: 01/04/2024] [Indexed: 01/31/2024]
Abstract
Luteinizing hormone (LH) is a useful biomarker for identifying ovulation events in the cows to predict the time of ovulation to achieve a high success rate of conception following artificial insemination. Although antibody-based radioimmunoassay and enzyme-linked immunosorbent assay are being used for LH measurement, these techniques are expensive, time-consuming, and require expertise and sophisticated laboratory facilities. So, there is a need for a field-applicable, affordable, easy-to-use method for LH detection. For developing such a specific, quantitative, and inexpensive system, an aptamer-based smartphone-enabled aptasensor has been investigated. The aptamer was used instead of the antibody as a biorecognition element due to its comparative stability at ambient temperature, ease of synthesis, and cost-effectiveness. Electrochemical impedance spectroscopy has been used to obtain label-free detection of LH within 20 min in ~ 20 μL sample volume. The screen-printed gold electrode is compatible with a smartphone-enabled miniaturized device (Sensit Smart; Palmsens BV, The Netherlands) and was fabricated with the aptamer to detect LH in biological fluids (limit of detection 0.80 and 0.61 ng/mL in buffer and undiluted/unprocessed serum, respectively, with the dynamic range of detection of 0.01 to 50 ng/mL). All the data were obtained in the 10 kHz to 0.10 Hz frequency range at a bias potential of 0.30 V with an alternating potential of 10 mV. The clinical relevance of the sensor was evaluated in 10 serum samples collected from dairy animals which established a high correlation with standard LH-ELISA (κ > 0.87). The aptasensor can be stored at room temperature for 30 days without any significant loss in electrochemical sensing ability.
Collapse
Affiliation(s)
- Pankaj Kumar
- Animal Biotechnology Laboratory, National Institute of Animal Biotechnology, near Gowlidoddi Extended Q City Road, Gachibowli, Hyderabad, 500032, Telangana, India
- Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - Arumugam Anitha
- Animal Biotechnology Laboratory, National Institute of Animal Biotechnology, near Gowlidoddi Extended Q City Road, Gachibowli, Hyderabad, 500032, Telangana, India
| | - Ankita Das
- Animal Biotechnology Laboratory, National Institute of Animal Biotechnology, near Gowlidoddi Extended Q City Road, Gachibowli, Hyderabad, 500032, Telangana, India
- Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - Govindarajan Deepalakshmi
- Animal Biotechnology Laboratory, National Institute of Animal Biotechnology, near Gowlidoddi Extended Q City Road, Gachibowli, Hyderabad, 500032, Telangana, India
| | - Pankaj Suman
- Animal Biotechnology Laboratory, National Institute of Animal Biotechnology, near Gowlidoddi Extended Q City Road, Gachibowli, Hyderabad, 500032, Telangana, India.
- Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India.
| |
Collapse
|
3
|
Gu Y, Li Y, Wu Q, Wu Z, Sun L, Shang Y, Zhuang Y, Fan X, Yi L, Wang S. Chemical antifouling strategies in sensors for food analysis: A review. Compr Rev Food Sci Food Saf 2023; 22:4074-4106. [PMID: 37421317 DOI: 10.1111/1541-4337.13209] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2022] [Revised: 04/26/2023] [Accepted: 06/20/2023] [Indexed: 07/10/2023]
Abstract
Surface biofouling induced by the undesired nonspecific adsorption of foulants (e.g., coexisting proteins and cells) in food matrices is a major issue of sensors for food analysis, hindering their reliability and accuracy of sensing. This issue can be addressed by developing antifouling strategies to prevent or alleviate nonspecific binding. Chemical antifouling strategies involve the use of chemical modifiers (i.e., antifouling materials) to strongly hydrate the surface and reduce surface biofouling. Through appropriate immobilization approaches, antifouling materials can be tethered onto sensors to form antifouling surfaces with well-ordered structures, balanced surface charges, and appropriate surface density and thickness. A rational antifouling surface can reduce the matrix effect, simplify sample pretreatment, and improve analytical performance. This review summarizes recent developments in chemical antifouling strategies in sensing. Surface antifouling mechanisms and common antifouling materials are described, and factors that may influence the antifouling effects of antifouling surfaces and approaches incorporating antifouling materials onto sensing surfaces are highlighted. Moreover, the specific applications of antifouling sensors in food analysis are introduced. Finally, we provide an outlook on future developments in antifouling sensors for food analysis.
Collapse
Affiliation(s)
- Ying Gu
- Faculty of Food Science and Engineering, Kunming University of Science and Technology, Kunming, China
| | - Yonghui Li
- Faculty of Food Science and Engineering, Kunming University of Science and Technology, Kunming, China
| | - Qiyue Wu
- Faculty of Food Science and Engineering, Kunming University of Science and Technology, Kunming, China
| | - Zhongdong Wu
- Faculty of Food Science and Engineering, Kunming University of Science and Technology, Kunming, China
| | - Liping Sun
- Faculty of Food Science and Engineering, Kunming University of Science and Technology, Kunming, China
| | - Ying Shang
- Faculty of Food Science and Engineering, Kunming University of Science and Technology, Kunming, China
| | - Yongliang Zhuang
- Faculty of Food Science and Engineering, Kunming University of Science and Technology, Kunming, China
| | - Xuejing Fan
- Faculty of Food Science and Engineering, Kunming University of Science and Technology, Kunming, China
| | - Lunzhao Yi
- Faculty of Food Science and Engineering, Kunming University of Science and Technology, Kunming, China
| | - Shuo Wang
- Tianjin Key Laboratory of Food Science and Health, School of Medicine, Nankai University, Tianjin, China
| |
Collapse
|
4
|
Parihar A, Yadav S, Sadique MA, Ranjan P, Kumar N, Singhal A, Khare V, Khan R, Natarajan S, Srivastava AK. Internet-of-medical-things integrated point-of-care biosensing devices for infectious diseases: Toward better preparedness for futuristic pandemics. Bioeng Transl Med 2023; 8:e10481. [PMID: 37206204 PMCID: PMC10189496 DOI: 10.1002/btm2.10481] [Citation(s) in RCA: 14] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2022] [Revised: 12/15/2022] [Accepted: 12/19/2022] [Indexed: 01/04/2023] Open
Abstract
Microbial pathogens have threatened the world due to their pathogenicity and ability to spread in communities. The conventional laboratory-based diagnostics of microbes such as bacteria and viruses need bulky expensive experimental instruments and skilled personnel which limits their usage in resource-limited settings. The biosensors-based point-of-care (POC) diagnostics have shown huge potential to detect microbial pathogens in a faster, cost-effective, and user-friendly manner. The use of various transducers such as electrochemical and optical along with microfluidic integrated biosensors further enhances the sensitivity and selectivity of detection. Additionally, microfluidic-based biosensors offer the advantages of multiplexed detection of analyte and the ability to deal with nanoliters volume of fluid in an integrated portable platform. In the present review, we discussed the design and fabrication of POCT devices for the detection of microbial pathogens which include bacteria, viruses, fungi, and parasites. The electrochemical techniques and current advances in this field in terms of integrated electrochemical platforms that include mainly microfluidic- based approaches and smartphone and Internet-of-things (IoT) and Internet-of-Medical-Things (IoMT) integrated systems have been highlighted. Further, the availability of commercial biosensors for the detection of microbial pathogens will be briefed. In the end, the challenges while fabrication of POC biosensors and expected future advances in the field of biosensing have been discussed. The integrated biosensor-based platforms with the IoT/IoMT usually collect the data to track the community spread of infectious diseases which would be beneficial in terms of better preparedness for current and futuristic pandemics and is expected to prevent social and economic losses.
Collapse
Affiliation(s)
- Arpana Parihar
- Industrial Waste Utilization, Nano and Biomaterials, CSIR‐Advanced Materials and Processes Research Institute (AMPRI)BhopalMadhya PradeshIndia
| | - Shalu Yadav
- Industrial Waste Utilization, Nano and Biomaterials, CSIR‐Advanced Materials and Processes Research Institute (AMPRI)BhopalMadhya PradeshIndia
- Academy of Scientific and Innovative Research (AcSIR)GhaziabadIndia
| | - Mohd Abubakar Sadique
- Industrial Waste Utilization, Nano and Biomaterials, CSIR‐Advanced Materials and Processes Research Institute (AMPRI)BhopalMadhya PradeshIndia
- Academy of Scientific and Innovative Research (AcSIR)GhaziabadIndia
| | - Pushpesh Ranjan
- Industrial Waste Utilization, Nano and Biomaterials, CSIR‐Advanced Materials and Processes Research Institute (AMPRI)BhopalMadhya PradeshIndia
- Academy of Scientific and Innovative Research (AcSIR)GhaziabadIndia
| | - Neeraj Kumar
- Industrial Waste Utilization, Nano and Biomaterials, CSIR‐Advanced Materials and Processes Research Institute (AMPRI)BhopalMadhya PradeshIndia
- Academy of Scientific and Innovative Research (AcSIR)GhaziabadIndia
| | - Ayushi Singhal
- Industrial Waste Utilization, Nano and Biomaterials, CSIR‐Advanced Materials and Processes Research Institute (AMPRI)BhopalMadhya PradeshIndia
- Academy of Scientific and Innovative Research (AcSIR)GhaziabadIndia
| | - Vedika Khare
- School of Nanotechnology, UTD, RGPV CampusBhopalMadhya PradeshIndia
| | - Raju Khan
- Industrial Waste Utilization, Nano and Biomaterials, CSIR‐Advanced Materials and Processes Research Institute (AMPRI)BhopalMadhya PradeshIndia
- Academy of Scientific and Innovative Research (AcSIR)GhaziabadIndia
| | - Sathish Natarajan
- Industrial Waste Utilization, Nano and Biomaterials, CSIR‐Advanced Materials and Processes Research Institute (AMPRI)BhopalMadhya PradeshIndia
- Academy of Scientific and Innovative Research (AcSIR)GhaziabadIndia
| | - Avanish K. Srivastava
- Industrial Waste Utilization, Nano and Biomaterials, CSIR‐Advanced Materials and Processes Research Institute (AMPRI)BhopalMadhya PradeshIndia
- Academy of Scientific and Innovative Research (AcSIR)GhaziabadIndia
| |
Collapse
|
5
|
Sharafeldin M, Davis JJ. Characterising the biosensing interface. Anal Chim Acta 2022; 1216:339759. [DOI: 10.1016/j.aca.2022.339759] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 02/08/2022] [Accepted: 03/22/2022] [Indexed: 12/19/2022]
|
6
|
Chen X, Ma Y, Gui Q, Hu S, Pan W, Lan Y, Zeng M, Zhou T, Su Z. An antifouling polymer for dynamic anti-protein adhesion analysis by a quartz crystal microbalance. Analyst 2021; 146:4636-4641. [PMID: 34169938 DOI: 10.1039/d1an00856k] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Nowadays, the non-specific adsorption of biomolecules is a key issue in numerous fields. Herein, an improved antifouling molecule was synthesized by grafting phenol with oligopoly (ethylene glycol), named (4-(2-(2-ethoxyethoxy) ethoxy) phenol (EEP). An ideal antifouling polymer coating (PEEP) was synthesized by the mechanism of electropolymerization of phenol. Quartz crystal microbalance (QCM), a sensitive mass sensor, was used to dynamically monitor both the modification and anti-protein adhesion (with bovine serum albumin as the model) process. Quantitatively, less proteins were observed to adhere to the modified electrode (277.8 ng for bare GCE and 8.88 ng for the modified GCE). Fourier transform infrared spectrophotometry (FT-IR), scanning electron microscopy (SEM), and electrochemical methods were used to study the coatings in detail. In this study, EEP was synthesized for the electrochemical preparation of an antifouling coating and characterized by QCM and electrochemical methods. The mild preparation environment (lower potential window and in phosphate buffered saline) and one-step method enable potential applications of PEEP in the field of biomaterials and biosensors.
Collapse
Affiliation(s)
- Ximing Chen
- College of Chemistry and Materials Science, Hunan Agricultural University, Changsha 410128, PR China.
| | - Yan Ma
- College of Chemistry and Materials Science, Hunan Agricultural University, Changsha 410128, PR China. and Guangdong Dayuan Oasis Food Safety Technology Co., Ltd, Guangzhou 510000, PR China
| | - Qingwen Gui
- College of Chemistry and Materials Science, Hunan Agricultural University, Changsha 410128, PR China.
| | - Shiyu Hu
- College of Chemistry and Materials Science, Hunan Agricultural University, Changsha 410128, PR China.
| | - Weisong Pan
- Hunan Provincial Engineering Technology Research Center for Cell Mechanics and Function Analysis, Changsha 410128, PR China and College of Bioscience and Biotechnology, Hunan Agricultural University, Changsha 410128, PR China.
| | - Yaqin Lan
- Hunan Provincial Engineering Technology Research Center for Cell Mechanics and Function Analysis, Changsha 410128, PR China and College of Bioscience and Biotechnology, Hunan Agricultural University, Changsha 410128, PR China.
| | - Mei Zeng
- Hunan Provincial Engineering Technology Research Center for Cell Mechanics and Function Analysis, Changsha 410128, PR China and College of Bioscience and Biotechnology, Hunan Agricultural University, Changsha 410128, PR China.
| | - Tiean Zhou
- Hunan Provincial Engineering Technology Research Center for Cell Mechanics and Function Analysis, Changsha 410128, PR China and College of Bioscience and Biotechnology, Hunan Agricultural University, Changsha 410128, PR China.
| | - Zhaohong Su
- College of Chemistry and Materials Science, Hunan Agricultural University, Changsha 410128, PR China. and Hunan Provincial Engineering Technology Research Center for Cell Mechanics and Function Analysis, Changsha 410128, PR China
| |
Collapse
|
7
|
Molecular diagnostic of toxigenic Corynebacterium diphtheriae strain by DNA sensor potentially suitable for electrochemical point-of-care diagnostic. Talanta 2021; 227:122161. [PMID: 33714465 DOI: 10.1016/j.talanta.2021.122161] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2020] [Revised: 01/21/2021] [Accepted: 01/26/2021] [Indexed: 12/12/2022]
Abstract
The presented study is focused on the development of electrochemical genosensor for detection of tox gene fragment of toxigenic Corynebacterium diphtheriae strain. Together with our previous studies it fulfils the whole procedure for fast and accurate diagnostic of diphtheria at its early stage of infection with the use of electrochemical methods. The developed DNA sensor potentially can be used in more sophisticated portable device. After the electrochemical stem-loop probe structure optimization the conditions for real asymmetric PCR (aPCR) product detection were selected. As was shown it was crucial to optimize the magnesium and organic solvent concentrations in detection buffer. Under optimal conditions it was possible to selectively detect as low as 20.8 nM of complementary stand in 5 min or 0.5 nM in 30 min with sensitivity of 12.81 and 0.24 1⋅μM-1 respectively. The unspecific biosensor response was elucidated with the use of new electrode blocking agent, diethyldithiocarbamate. Its application in electrochemical genosensors lead to significant higher current values and the biosensor response even in conditions with magnesium ion depletion. The developed biosensor selectivity was examined using samples containing genetic material originated from a number of non-target bacterial species which potentially can be present in the human upper respiratory tract.
Collapse
|
8
|
Rakshit S, Ghosh S, Roy R, Bhattacharya SC. Non-enzymatic electrochemical glucose sensing by Cu2O octahedrons: elucidating the protein adsorption signature. NEW J CHEM 2021. [DOI: 10.1039/d0nj04431h] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Developing an electrochemical biosensor based on Cu2O octahedrons for rapid, sensitive and highly selective detection of glucose in real samples with an unprecedented analysis of their protein adsorption signature.
Collapse
Affiliation(s)
| | - Srabanti Ghosh
- Department of Chemical, Biological and Macromolecular Sciences
- S. N. Bose National Centre for Basic Sciences
- Kolkata 700 098
- India
| | - Rimi Roy
- Department of Chemistry
- Presidency University
- Kolkata 700 073
- India
| | | |
Collapse
|