1
|
Annecchino LA, Schultz SR. Progress in automating patch clamp cellular physiology. Brain Neurosci Adv 2018; 2:2398212818776561. [PMID: 32166142 PMCID: PMC7058203 DOI: 10.1177/2398212818776561] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2018] [Accepted: 04/19/2018] [Indexed: 12/30/2022] Open
Abstract
Patch clamp electrophysiology has transformed research in the life sciences over the last few decades. Since their inception, automatic patch clamp platforms have evolved considerably, demonstrating the capability to address both voltage- and ligand-gated channels, and showing the potential to play a pivotal role in drug discovery and biomedical research. Unfortunately, the cell suspension assays to which early systems were limited cannot recreate biologically relevant cellular environments, or capture higher order aspects of synaptic physiology and network dynamics. In vivo patch clamp electrophysiology has the potential to yield more biologically complex information and be especially useful in reverse engineering the molecular and cellular mechanisms of single-cell and network neuronal computation, while capturing important aspects of human disease mechanisms and possible therapeutic strategies. Unfortunately, it is a difficult procedure with a steep learning curve, which has restricted dissemination of the technique. Luckily, in vivo patch clamp electrophysiology seems particularly amenable to robotic automation. In this review, we document the development of automated patch clamp technology, from early systems based on multi-well plates through to automated planar-array platforms, and modern robotic platforms capable of performing two-photon targeted whole-cell electrophysiological recordings in vivo.
Collapse
Affiliation(s)
- Luca A. Annecchino
- Centre for Neurotechnology and Department of Bioengineering, Imperial College London, London, UK
| | - Simon R. Schultz
- Centre for Neurotechnology and Department of Bioengineering, Imperial College London, London, UK
| |
Collapse
|
2
|
Ossola D, Amarouch MY, Behr P, Vörös J, Abriel H, Zambelli T. Force-controlled patch clamp of beating cardiac cells. NANO LETTERS 2015; 15:1743-50. [PMID: 25639960 DOI: 10.1021/nl504438z] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
From its invention in the 1970s, the patch clamp technique is the gold standard in electrophysiology research and drug screening because it is the only tool enabling accurate investigation of voltage-gated ion channels, which are responsible for action potentials. Because of its key role in drug screening, innovation efforts are being made to reduce its complexity toward more automated systems. While some of these new approaches are being adopted in pharmaceutical companies, conventional patch-clamp remains unmatched in fundamental research due to its versatility. Here, we merged the patch clamp and atomic force microscope (AFM) techniques, thus equipping the patch-clamp with the sensitive AFM force control. This was possible using the FluidFM, a force-controlled nanopipette based on microchanneled AFM cantilevers. First, the compatibility of the system with patch-clamp electronics and its ability to record the activity of voltage-gated ion channels in whole-cell configuration was demonstrated with sodium (NaV1.5) channels. Second, we showed the feasibility of simultaneous recording of membrane current and force development during contraction of isolated cardiomyocytes. Force feedback allowed for a gentle and stable contact between AFM tip and cell membrane enabling serial patch clamping and injection without apparent cell damage.
Collapse
Affiliation(s)
- Dario Ossola
- Laboratory of Biosensors and Bioelectronics, Institute for Biomedical Engineering, ETH Zurich , Zurich, Switzerland
| | | | | | | | | | | |
Collapse
|
3
|
Bruhn BR, Liu H, Schuhladen S, Hunt AJ, Mordovanakis A, Mayer M. Dual-pore glass chips for cell-attached single-channel recordings. LAB ON A CHIP 2014; 14:2410-7. [PMID: 24844315 PMCID: PMC4121072 DOI: 10.1039/c4lc00370e] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
While high-throughput planar patch-clamp instruments are now established to perform whole-cell recordings for drug screening, the conventional micropipette-based approach remains the gold standard for performing cell-attached single-channel recordings. Generally, planar platforms are not well-suited for such studies due to excess noise resulting from low seal resistances and the use of substrates with poor dielectric properties. Since these platforms tend to use the same pore to position a cell by suction and establish a seal, biological debris from the cell suspension can contaminate the pore surface prior to seal formation, reducing the seal resistance. Here, femtosecond laser ablation was used to fabricate dual-pore glass chips optimized for use in cell-attached single-channel recordings that circumvent this problem by using different pores to position a cell and to establish a seal. This dual-pore design also permitted the use of a relatively small patch aperture (D ~ 150 to 300 nm) that is better-suited for establishing high-resistance seals than the micropores used typically in planar patch-clamp setups (D ~ 1 to 2 μm) without compromising the ability of the device to position a cell. Taking advantage of the high seal resistances and low capacitive and dielectric noise realized using glass substrates, patch-clamp experiments with these dual-pore chips consistently achieved high seal resistances (rate of gigaseal formation = 61%, mean seal resistance = 53 GΩ), maintained gigaseals for prolonged durations (up to 6 hours), achieved RMS noise values as low as 0.46 pA at 5 kHz bandwidth, and enabled single-channel recordings in the cell-attached configuration that are comparable to those obtained by conventional patch-clamp.
Collapse
Affiliation(s)
- Brandon R Bruhn
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109, USA.
| | | | | | | | | | | |
Collapse
|
4
|
Modification of silicon oxide surfaces by monolayers of an oligoethylene glycol-terminated perfluoroalkyl silane. Colloids Surf A Physicochem Eng Asp 2014. [DOI: 10.1016/j.colsurfa.2014.02.015] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
5
|
Surface characteristics and electrical properties of PMMA chips for incubation-type planar-patch-clamp biosensors. Colloids Surf B Biointerfaces 2014; 116:193-200. [PMID: 24480066 DOI: 10.1016/j.colsurfb.2013.12.055] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2013] [Revised: 12/20/2013] [Accepted: 12/21/2013] [Indexed: 11/22/2022]
Abstract
Polymethylmethacrylate (PMMA) plates were successfully applied as sensor chips in an incubation-type planar patch clamp (IPPC). Hot embossing both sides formed the PMMA plates, and a focused ion beam realized micropores. The low seal resistance of the IPPC was investigated by analyzing the surface roughness of the chips. Atomic force microscopy (AFM) showed that the chip surface had a roughness of several nanometers due to the molding process. Coating the molded surface with an anti-adhesive compound further increased the surface roughness of the PMMA chip because the anti-adhesive compound itself had a large roughness and in some case, the compound partially peeled off while detaching the mold. Similarly, coating a chip with extracellular matrix (ECM) poly-l-lysine (PLL) also increased the surface roughness. The measured seal resistance of the PMMA chip for an HEK293 cell was in the range of 4-15 MΩ. The low seal resistance was attributed to the sharp-edge structure of the micropore and the surface roughness of the chip. Nevertheless, the whole cell current was successfully recorded from HEK293 cells expressing channel rhodopsin wide receiver (ChRWR) using salt-bridge-type stable Ag/AgCl electrodes. Another advantage of the PMMA sensor chip was the small parasitic capacitance.
Collapse
|
6
|
Bosca A, Martina M, Py C. Planar patch clamp for neuronal networks--considerations and future perspectives. Methods Mol Biol 2014; 1183:93-113. [PMID: 25023304 DOI: 10.1007/978-1-4939-1096-0_6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
The patch-clamp technique is generally accepted as the gold standard for studying ion channel activity allowing investigators to either "clamp" membrane voltage and directly measure transmembrane currents through ion channels, or to passively monitor spontaneously occurring intracellular voltage oscillations. However, this resulting high information content comes at a price. The technique is labor-intensive and requires highly trained personnel and expensive equipment. This seriously limits its application as an interrogation tool for drug development. Patch-clamp chips have been developed in the last decade to overcome the tedious manipulations associated with the use of glass pipettes in conventional patch-clamp experiments. In this chapter, we describe some of the main materials and fabrication protocols that have been developed to date for the production of patch-clamp chips. We also present the concept of a patch-clamp chip array providing high resolution patch-clamp recordings from individual cells at multiple sites in a network of communicating neurons. On this chip, the neurons are aligned with the aperture-probes using chemical patterning. In the discussion we review the potential use of this technology for pharmaceutical assays, neuronal physiology and synaptic plasticity studies.
Collapse
Affiliation(s)
- Alessandro Bosca
- Italian Institute of Technology, Via Morego 30, 16163, Genoa, Italy,
| | | | | |
Collapse
|
7
|
Tanzi S, Matteucci M, Christiansen TL, Friis S, Christensen MT, Garnaes J, Wilson S, Kutchinsky J, Taboryski R. Ion channel recordings on an injection-molded polymer chip. LAB ON A CHIP 2013; 13:4784-4793. [PMID: 24154831 DOI: 10.1039/c3lc50760b] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
In this paper, we demonstrate recordings of the ion channel activity across the cell membrane in a biological cell by employing the so-called patch clamping technique on an injection-molded polymer microfluidic device. The findings will allow direct recordings of ion channel activity to be made using the cheapest materials and production platform to date and with the potential for very high throughput. The employment of cornered apertures for cell capture allowed the fabrication of devices without through holes and via a scheme comprising master origination by dry etching in a silicon substrate, electroplating in nickel and injection molding of the final part. The most critical device parameters were identified as the length of the patching capillary and the very low surface roughness on the inside of the capillary. The cross-sectional shape of the orifice was found to be less critical, as both rectangular and semicircular profiles seemed to have almost the same ability to form tight seals with cells with negligible leak currents. The devices were functionally tested using human embryonic kidney cells expressing voltage-gated sodium channels (Nav1.7) and benchmarked against a commercial state-of-the-art system for automated ion channel recordings. These experiments considered current-voltage (IV) relationships for activation and inactivation of the Nav1.7 channels and their sensitivity to a local anesthetic, lidocaine. Both IVs and lidocaine dose-response curves obtained from the injection-molded polymer device were in good agreement with data obtained from the commercial system.
Collapse
Affiliation(s)
- Simone Tanzi
- Department of Micro- and Nanotechnology, Technical University of Denmark, Building 345E, DK-2800 Kongens Lyngby, Denmark.
| | | | | | | | | | | | | | | | | |
Collapse
|
8
|
Braeken D, Jans D, Huys R, Stassen A, Collaert N, Hoffman L, Eberle W, Peumans P, Callewaert G. Open-cell recording of action potentials using active electrode arrays. LAB ON A CHIP 2012; 12:4397-402. [PMID: 22930315 DOI: 10.1039/c2lc40656j] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
The investigation of complex communication in cellular networks requires superior measurement tools than those available to date. Electrode arrays integrated onto silicon electronics are increasingly used to measure the electrical activity of cells in an automated and highly parallelized fashion, but they are restricted to recording extracellular potentials. Here, we report on an array of TiN electrodes built using standard silicon electronics for intracellular action potential recording. Intracellular access, possible at each of the 16 384 electrodes on the chip, was accomplished by local membrane electroporation using electrical stimulation with subcellular, micrometer-sized electrodes. Access to the cell interior was transient and could be tuned in duration by adapting the electroporation protocol. Intracellular sensing was found to be minimally invasive in the short and long-term, allowing consecutive intracellular recordings from the same cell over the course of days. Finally, we applied this method to investigate the effect of an ion channel blocker on cardiac electrical activity. This technique opens the door to massively parallel, long-term intracellular recording for fundamental electrophysiology and drug screening.
Collapse
Affiliation(s)
- Dries Braeken
- Bio-Nano Electronics, Imec, Kapeldreef 75, Leuven, 3001, Belgium.
| | | | | | | | | | | | | | | | | |
Collapse
|
9
|
Boussaoud A, Fonteille I, Collier G, Kermarrec F, Vermont F, Tresallet E, De Waard M, Arnoult C, Picollet-D'hahan N. A miniaturized planar patch-clamp system for transportable use. Biosens Bioelectron 2011; 32:96-103. [PMID: 22208956 DOI: 10.1016/j.bios.2011.11.042] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2011] [Revised: 11/22/2011] [Accepted: 11/23/2011] [Indexed: 11/24/2022]
Abstract
In the last decade, planar patch-clamp (PPC) has emerged as an innovative technology allowing parallel recordings of cellular electrophysiological activity on planar substrates. If PPC is widely adopted by the pharmaceutical sector, it remains poorly extended to other areas (i.e. environment and safety organizations) probably because of the large, expensive and non-easily transportable format of those commercial equipments. The present work describes for the first time a new compact and transportable planar patch-clamp system (named Toxint'patch or TIP, for Toxin detection with integrated patch-clamp) focusing on environmental matters and meant to be used in coastal laboratories, for direct on-site monitoring of the seawater and shellfish quality. The TIP system incorporates silicon chips tailored to monitor cellular ionic currents from cultured cells stably expressing a phycotoxin molecular target. The functionality of this novel briefcase-sized PPC system is described in terms of fluidic control, electronic performances with amplifying and filtering boards and of user interface for data acquisition and control implemented on a computer.
Collapse
Affiliation(s)
- Adrien Boussaoud
- CEA, DSV iRTSV, Biologie à Grande Echelle, F-38054 Grenoble, France
| | | | | | | | | | | | | | | | | |
Collapse
|
10
|
Py C, Martina M, Diaz-Quijada GA, Luk CC, Martinez D, Denhoff MW, Charrier A, Comas T, Monette R, Krantis A, Syed NI, Mealing GAR. From understanding cellular function to novel drug discovery: the role of planar patch-clamp array chip technology. Front Pharmacol 2011; 2:51. [PMID: 22007170 PMCID: PMC3184600 DOI: 10.3389/fphar.2011.00051] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2011] [Accepted: 09/05/2011] [Indexed: 11/20/2022] Open
Abstract
All excitable cell functions rely upon ion channels that are embedded in their plasma membrane. Perturbations of ion channel structure or function result in pathologies ranging from cardiac dysfunction to neurodegenerative disorders. Consequently, to understand the functions of excitable cells and to remedy their pathophysiology, it is important to understand the ion channel functions under various experimental conditions - including exposure to novel drug targets. Glass pipette patch-clamp is the state of the art technique to monitor the intrinsic and synaptic properties of neurons. However, this technique is labor intensive and has low data throughput. Planar patch-clamp chips, integrated into automated systems, offer high throughputs but are limited to isolated cells from suspensions, thus limiting their use in modeling physiological function. These chips are therefore not most suitable for studies involving neuronal communication. Multielectrode arrays (MEAs), in contrast, have the ability to monitor network activity by measuring local field potentials from multiple extracellular sites, but specific ion channel activity is challenging to extract from these multiplexed signals. Here we describe a novel planar patch-clamp chip technology that enables the simultaneous high-resolution electrophysiological interrogation of individual neurons at multiple sites in synaptically connected neuronal networks, thereby combining the advantages of MEA and patch-clamp techniques. Each neuron can be probed through an aperture that connects to a dedicated subterranean microfluidic channel. Neurons growing in networks are aligned to the apertures by physisorbed or chemisorbed chemical cues. In this review, we describe the design and fabrication process of these chips, approaches to chemical patterning for cell placement, and present physiological data from cultured neuronal cells.
Collapse
Affiliation(s)
- Christophe Py
- Institute for Microstructural Sciences, National Research Council of CanadaOttawa, ON, Canada
| | - Marzia Martina
- Institute for Biological Sciences, National Research Council of CanadaOttawa, ON, Canada
| | - Gerardo A. Diaz-Quijada
- Steacie Institute for Molecular Sciences, National Research Council of CanadaOttawa, ON, Canada
| | - Collin C. Luk
- Hotchkiss Brain Institute, University of CalgaryCalgary, AB, Canada
| | - Dolores Martinez
- Institute for Microstructural Sciences, National Research Council of CanadaOttawa, ON, Canada
| | - Mike W. Denhoff
- Institute for Microstructural Sciences, National Research Council of CanadaOttawa, ON, Canada
| | - Anne Charrier
- Centre Interdisciplinaire de Nanoscience de Marseille, Centre National de la Recherche ScientifiqueMarseille, France
| | - Tanya Comas
- Institute for Biological Sciences, National Research Council of CanadaOttawa, ON, Canada
| | - Robert Monette
- Institute for Biological Sciences, National Research Council of CanadaOttawa, ON, Canada
| | - Anthony Krantis
- Centre for Research in Biopharmaceuticals and Biotechnology. University of OttawaOttawa, ON, Canada
| | - Naweed I. Syed
- Hotchkiss Brain Institute, University of CalgaryCalgary, AB, Canada
| | - Geoffrey A. R. Mealing
- Institute for Biological Sciences, National Research Council of CanadaOttawa, ON, Canada
| |
Collapse
|