Sun Y, Wang B, Deng Y, Cheng H, Li X, Yan L, Li G, Sun W. Reduced graphene oxide/titanium carbide
MXene nanocomposite‐modified
electrode for electrochemical hemoglobin biosensor. J CHIN CHEM SOC-TAIP 2021. [DOI: 10.1002/jccs.202100229] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Yunxiu Sun
- Key Laboratory of Optic‐electric Sensing and Analytical Chemistry for Life Science of Ministry of Education College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology Qingdao PR China
| | - Baoli Wang
- Key Laboratory of Laser Technology and Optoelectronic Functional Materials of Hainan Province, Key Laboratory of Functional Materials and Photoelectrochemistry of Haikou College of Chemistry and Chemical Engineering, Hainan Normal University Haikou China
| | - Ying Deng
- Key Laboratory of Laser Technology and Optoelectronic Functional Materials of Hainan Province, Key Laboratory of Functional Materials and Photoelectrochemistry of Haikou College of Chemistry and Chemical Engineering, Hainan Normal University Haikou China
| | - Hui Cheng
- Key Laboratory of Optic‐electric Sensing and Analytical Chemistry for Life Science of Ministry of Education College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology Qingdao PR China
| | - Xiaoqing Li
- Key Laboratory of Laser Technology and Optoelectronic Functional Materials of Hainan Province, Key Laboratory of Functional Materials and Photoelectrochemistry of Haikou College of Chemistry and Chemical Engineering, Hainan Normal University Haikou China
| | - Lijun Yan
- Key Laboratory of Laser Technology and Optoelectronic Functional Materials of Hainan Province, Key Laboratory of Functional Materials and Photoelectrochemistry of Haikou College of Chemistry and Chemical Engineering, Hainan Normal University Haikou China
| | - Guangjiu Li
- Key Laboratory of Optic‐electric Sensing and Analytical Chemistry for Life Science of Ministry of Education College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology Qingdao PR China
| | - Wei Sun
- Key Laboratory of Laser Technology and Optoelectronic Functional Materials of Hainan Province, Key Laboratory of Functional Materials and Photoelectrochemistry of Haikou College of Chemistry and Chemical Engineering, Hainan Normal University Haikou China
| |
Collapse
|
2
|
Hedayatnasab Z, Dabbagh A, Abnisa F, Wan Daud WMA. Polycaprolactone-coated superparamagnetic iron oxide nanoparticles for in vitro magnetic hyperthermia therapy of cancer. Eur Polym J 2020. [DOI: 10.1016/j.eurpolymj.2020.109789] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
3
|
Nerimetla R, Premaratne G, Liu H, Krishnan S. Improved electrocatalytic metabolite production and drug biosensing by human liver microsomes immobilized on amine-functionalized magnetic nanoparticles. Electrochim Acta 2018. [DOI: 10.1016/j.electacta.2018.05.085] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
|
4
|
Sun C, Zou Y, Wang D, Geng Z, Xu W, Liu F, Cao J. Construction of Chitosan-Zn-Based Electrochemical Biosensing Platform for Rapid and Accurate Assay of Actin. SENSORS 2018; 18:s18061865. [PMID: 29875352 PMCID: PMC6021900 DOI: 10.3390/s18061865] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/25/2018] [Revised: 05/28/2018] [Accepted: 06/05/2018] [Indexed: 01/21/2023]
Abstract
This work reports a study on the development of a sensitive immunosensor for the assay of actin, which is fabricated using sensing material chitosan-Zn nanoparticles (NPs) and anti-actin modified on glassy carbon electrode respectively. The prepared materials were characterized using transmission electron microscope (TEM), fourier transform infrared spectra (FTIR), X-ray diffraction (XRD) spectra, and circular dichroism (CD) techniques. Meanwhile, the electrochemical properties were studied by linear sweep voltammetric (LSV), electrochemical impedance spectra (EIS), and differential pulse voltammetry (DPV). According to the experiments, under the optimum conditions, the linear fitting equation was I (μA) = −17.31 + 78.97c (R2 = 0.9948). The linear range was from 0.0001 to 0.1 mg/mL and the detection limit (LOD, S/N = 3) was 21.52 ng/mL. The interference studies were also performed for checking the sensors’ selectivity to actin. With better properties of the chitosan-Zn NPs, the modified electrode is considered as a better candidate than Western blot or immunohistochemical method for real-time usability. The detection limit reported is the lowest till date and this method provides a new approach for quality evaluation.
Collapse
Affiliation(s)
- Chong Sun
- Institute of Agricultural Products Processing, Jiangsu Academy of Agricultural Sciences, Nanjing 210014, China.
| | - Ye Zou
- Institute of Agricultural Products Processing, Jiangsu Academy of Agricultural Sciences, Nanjing 210014, China.
| | - Daoying Wang
- Institute of Agricultural Products Processing, Jiangsu Academy of Agricultural Sciences, Nanjing 210014, China.
- Jiangsu Key Laboratory for Food Quality and Safety-State Key Laboratory Cultivation Base of Ministry of Science and Technology, Nanjing 210014, China.
| | - Zhiming Geng
- Institute of Agricultural Products Processing, Jiangsu Academy of Agricultural Sciences, Nanjing 210014, China.
| | - Weimin Xu
- Institute of Agricultural Products Processing, Jiangsu Academy of Agricultural Sciences, Nanjing 210014, China.
| | - Fang Liu
- Institute of Agricultural Products Processing, Jiangsu Academy of Agricultural Sciences, Nanjing 210014, China.
| | - Jinxuan Cao
- Key Laboratory of Animal Protein Food Processing Technology of Zhejiang Province, Ningbo University, Ningbo 315211, China.
| |
Collapse
|
5
|
Monteiro T, Almeida MG. Electrochemical Enzyme Biosensors Revisited: Old Solutions for New Problems. Crit Rev Anal Chem 2018; 49:44-66. [PMID: 29757683 DOI: 10.1080/10408347.2018.1461552] [Citation(s) in RCA: 43] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
Abstract
Worldwide legislation is driving the development of novel and highly efficient analytical tools for assessing the composition of every material that interacts with Consumers or Nature. The biosensor technology is one of the most active R&D domains of Analytical Sciences focused on the challenge of taking analytical chemistry to the field. Electrochemical biosensors based on redox enzymes, in particular, are highly appealing due to their usual quick response, high selectivity and sensitivity, low cost and portable dimensions. This review paper aims to provide an overview of the most important advances made in the field since the proposal of the first biosensor, the well-known hand-held glucose meter. The first section addresses the current needs and challenges for novel analytical tools, followed by a brief description of the different components and configurations of biosensing devices, and the fundamentals of enzyme kinetics and amperometry. The following sections emphasize on enzyme-based amperometric biosensors and the different stages of their development.
Collapse
Affiliation(s)
- Tiago Monteiro
- a UCIBIO-REQUIMTE, Faculdade de Ciências e Tecnologia, Universidade NOVA de Lisboa , Caparica , Portugal
| | | |
Collapse
|
6
|
Design and tailoring of a three-dimensional reduced graphene oxide/helical carbon nanotube composite for electrochemical biosensing application. J Solid State Electrochem 2017. [DOI: 10.1007/s10008-017-3711-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
7
|
Baghayeri M, Rouhi M, Lakouraj MM, Amiri-Aref M. Bioelectrocatalysis of hydrogen peroxide based on immobilized hemoglobin onto glassy carbon electrode modified with magnetic poly(indole-co-thiophene) nanocomposite. J Electroanal Chem (Lausanne) 2017. [DOI: 10.1016/j.jelechem.2016.12.006] [Citation(s) in RCA: 44] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
8
|
Li G, Sun K, Li D, Lv P, Wang Q, Huang F, Wei Q. Biosensor based on bacterial cellulose-Au nanoparticles electrode modified with laccase for hydroquinone detection. Colloids Surf A Physicochem Eng Asp 2016. [DOI: 10.1016/j.colsurfa.2016.09.028] [Citation(s) in RCA: 44] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
9
|
Trojanowicz M. Impact of nanotechnology on design of advanced screen-printed electrodes for different analytical applications. Trends Analyt Chem 2016. [DOI: 10.1016/j.trac.2016.03.027] [Citation(s) in RCA: 64] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
10
|
Xu X, Song L, Zheng Q, Cao X, Yao C. General Preparation of Heme Protein Functional Fe3O4@Au-Nps Magnetic Nanocomposite for Sensitive Detection of Hydrogen Peroxide. ELECTROANAL 2016. [DOI: 10.1002/elan.201600457] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- Xuan Xu
- College of Chemistry and Molecular Engineering; Nanjing Tech University; Nanjing 211816, P. R. China
- Key Laboratory of Environmental Medicine Engineering; Ministry of Education; School of Public Health; Southeast University; Nanjing 210009 P. R. China
| | - Lishu Song
- College of Chemistry and Molecular Engineering; Nanjing Tech University; Nanjing 211816, P. R. China
| | - Qiqin Zheng
- College of Chemistry and Molecular Engineering; Nanjing Tech University; Nanjing 211816, P. R. China
| | - Xiaodong Cao
- College of Food Science and Engineering; Hefei University of Technology; Hefei 230009 P. R. China
| | - Cheng Yao
- College of Chemistry and Molecular Engineering; Nanjing Tech University; Nanjing 211816, P. R. China
| |
Collapse
|
11
|
Bagheri H, Ranjbari E, Amiri-Aref M, Hajian A, Ardakani YH, Amidi S. Modified fractal iron oxide magnetic nanostructure: A novel and high performance platform for redox protein immobilization, direct electrochemistry and bioelectrocatalysis application. Biosens Bioelectron 2016; 85:814-821. [PMID: 27290665 DOI: 10.1016/j.bios.2016.05.097] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2016] [Revised: 05/18/2016] [Accepted: 05/31/2016] [Indexed: 02/07/2023]
Abstract
A novel biosensing platform based on fractal-pattern of iron oxides magnetic nanostructures (FIOMNs) and mixed hemi/ad-micelle of sodium dodecyl sulfate (SDS) was designed for the magnetic immobilization of hemoglobin (Hb) at a screen printed carbon electrode (SPCE). The FIOMNs was successfully synthesized through hydrothermal approach and characterized by atomic force microscopy (AFM), scanning electron microscopy (SEM) and X-ray diffraction (XRD). In order to provide guidelines for the mixed hemi/ad-micelle formation, zeta-potential isotherms were investigated. The construction steps of the biosensor were evaluated by electrochemical impedance spectroscopy, cyclic voltammetry and Fourier transform infrared spectroscopy. Direct electron transfer of Hb incorporated into the biocomposite film was realized with a pair of quasi-reversible redox peak at the formal potential of -0.355V vs. Ag/AgCl attributing to heme Fe(III)/Fe(II) redox couple. The results suggested that synergistic functions regarding to the hyper-branched and multidirectional structure of FIOMNs and the dual interaction ability of mixed hemi/ad-micelle array of SDS molecules not only induce an effective electron transfer between the Hb and the underlying electrode (high heterogeneous electron transfer rate constant of 2.08s(-1)) but also provide powerful and special microenvironment for the adsorption of the redox proteins. Furthermore, the biosensor displayed an excellent performance to the electrocatalytic reduction of H2O2 with a detection limit of 0.48µM and Michaelis-Menten constant (Km) value of 44.2µM. The fabricated biosensor represented the features of sensitivity, disposable design, low sample volume, rapid and simple preparation step, and acceptable anti-interferences, which offer great perspectives for the screen-determination of H2O2 in real samples.
Collapse
Affiliation(s)
- Hasan Bagheri
- Chemical Injuries Research Center, Baqiyatallah University of Medical Sciences, Tehran, Iran.
| | - Elias Ranjbari
- Biopharmaceutics and Pharmacokinetics Division, Department of Pharmaceutics, Faculty of Pharmacy, Tehran University of Medical Sciences, Tehran 14155-6451, Iran
| | - Mohaddeseh Amiri-Aref
- Biopharmaceutics and Pharmacokinetics Division, Department of Pharmaceutics, Faculty of Pharmacy, Tehran University of Medical Sciences, Tehran 14155-6451, Iran
| | - Ali Hajian
- Laboratory for Sensors, Department of Microsystems Engineering (IMTEK), University of Freiburg, Georges Köhler Allee 103, 79110 Freiburg, Germany
| | - Yalda Hosseinzadeh Ardakani
- Biopharmaceutics and Pharmacokinetics Division, Department of Pharmaceutics, Faculty of Pharmacy, Tehran University of Medical Sciences, Tehran 14155-6451, Iran
| | - Salimeh Amidi
- Department of Medicinal Chemistry, School of Pharmacy, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| |
Collapse
|
12
|
Electrochemical Immunosensor Based on the Chitosan-Magnetic Nanoparticles for Detection of Tetracycline. FOOD ANAL METHOD 2016. [DOI: 10.1007/s12161-016-0480-z] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|