1
|
Moradi A, Zeinoddini M, Robatjazi SM. Rapid Concentration and Detection of Vibrio cholerae Using Magnetic Nanoparticles. J WATER CHEM TECHNO+ 2023. [DOI: 10.3103/s1063455x2301006x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/19/2023]
|
2
|
El-Sherif DM, Abouzid M, Gaballah MS, Ahmed AA, Adeel M, Sheta SM. New approach in SARS-CoV-2 surveillance using biosensor technology: a review. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2022; 29:1677-1695. [PMID: 34689274 PMCID: PMC8541810 DOI: 10.1007/s11356-021-17096-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/27/2021] [Accepted: 10/13/2021] [Indexed: 05/14/2023]
Abstract
Biosensors are analytical tools that transform the bio-signal into an observable response. Biosensors are effective for early detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection because they target viral antigens to assess clinical development and provide information on the severity and critical trends of infection. The biosensors are capable of being on-site, fast, and extremely sensitive to the target viral antigen, opening the door for early detection of SARS-CoV-2. They can screen individuals in hospitals, airports, and other crowded locations. Microfluidics and nanotechnology are promising cornerstones for the development of biosensor-based techniques. Recently, due to high selectivity, simplicity, low cost, and reliability, the production of biosensor instruments have attracted considerable interest. This review article precisely provides the extensive scientific advancement and intensive look of basic principles and implementation of biosensors in SARS-CoV-2 surveillance, especially for human health. In this review, the importance of biosensors including Optical, Electrochemical, Piezoelectric, Microfluidic, Paper-based biosensors, Immunosensors, and Nano-Biosensors in the detection of SARS-CoV-2 has been underscored. Smartphone biosensors and calorimetric strips that target antibodies or antigens should be developed immediately to combat the rapidly spreading SARS-CoV-2. Wearable biosensors can constantly monitor patients, which is a highly desired feature of biosensors. Finally, we summarized the literature, outlined new approaches and future directions in diagnosing SARS-CoV-2 by biosensor-based techniques.
Collapse
Affiliation(s)
- Dina M El-Sherif
- National Institute of Oceanography and Fisheries, NIOF, Cairo, Egypt.
| | - Mohamed Abouzid
- Department of Physical Pharmacy and Pharmacokinetics, Faculty of Pharmacy, Poznan University of Medical Sciences, 60-781, Poznan, Poland.
| | - Mohamed S Gaballah
- National Institute of Oceanography and Fisheries, NIOF, Cairo, Egypt
- College of Engineering, Key Laboratory for Clean Renewable Energy Utilization Technology, Ministry of Agriculture), China Agricultural University, Beijing, 100083, People's Republic of China
| | - Alhassan Ali Ahmed
- Department of Bioinformatics and Computational Biology, Poznan University of Medical Sciences, Poznan, Poland
| | - Muhammad Adeel
- BNU-HKUST Laboratory of Green Innovation, Advanced Institute of Natural Sciences, Beijing Normal University Zhuhai Subcampus, 18 Jinfeng Road, Tangjiawan, Zhuhai, Guangdong, China
| | - Sheta M Sheta
- Inorganic Chemistry Department, National Research Centre, 33 El-Behouth St., Dokki, Giza, 12622, Egypt
| |
Collapse
|
3
|
Haghdoust F, Molakarimi M, Mirshahi M, Sajedi RH. Engineering aequorin to improve thermostability through rigidifying flexible sites. J Mol Struct 2021. [DOI: 10.1016/j.molstruc.2021.130575] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
4
|
Immunodiagnostic of Vibrio cholerae O1 using localized surface plasmon resonance (LSPR) biosensor. Int Microbiol 2020; 24:115-122. [DOI: 10.1007/s10123-020-00148-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2020] [Revised: 10/13/2020] [Accepted: 10/27/2020] [Indexed: 12/17/2022]
|
5
|
Pirzada M, Altintas Z. Recent Progress in Optical Sensors for Biomedical Diagnostics. MICROMACHINES 2020; 11:E356. [PMID: 32235546 PMCID: PMC7231100 DOI: 10.3390/mi11040356] [Citation(s) in RCA: 43] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/01/2020] [Revised: 03/25/2020] [Accepted: 03/28/2020] [Indexed: 12/12/2022]
Abstract
In recent years, several types of optical sensors have been probed for their aptitude in healthcare biosensing, making their applications in biomedical diagnostics a rapidly evolving subject. Optical sensors show versatility amongst different receptor types and even permit the integration of different detection mechanisms. Such conjugated sensing platforms facilitate the exploitation of their neoteric synergistic characteristics for sensor fabrication. This paper covers nearly 250 research articles since 2016 representing the emerging interest in rapid, reproducible and ultrasensitive assays in clinical analysis. Therefore, we present an elaborate review of biomedical diagnostics with the help of optical sensors working on varied principles such as surface plasmon resonance, localised surface plasmon resonance, evanescent wave fluorescence, bioluminescence and several others. These sensors are capable of investigating toxins, proteins, pathogens, disease biomarkers and whole cells in varied sensing media ranging from water to buffer to more complex environments such as serum, blood or urine. Hence, the recent trends discussed in this review hold enormous potential for the widespread use of optical sensors in early-stage disease prediction and point-of-care testing devices.
Collapse
Affiliation(s)
| | - Zeynep Altintas
- Institute of Chemistry, Technical University of Berlin, Straße des 17. Juni 124, 10623 Berlin, Germany;
| |
Collapse
|
6
|
Ramamurthy T, Das B, Chakraborty S, Mukhopadhyay AK, Sack DA. Diagnostic techniques for rapid detection of Vibrio cholerae O1/O139. Vaccine 2019; 38 Suppl 1:A73-A82. [PMID: 31427135 DOI: 10.1016/j.vaccine.2019.07.099] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2019] [Revised: 07/11/2019] [Accepted: 07/31/2019] [Indexed: 01/25/2023]
Abstract
Cholera caused by the toxigenic Vibrio cholerae is still a major public health problem in many countries. This disease is mainly due to poor sanitation, hygiene and consumption of unsafe water. Several recent epidemics of cholera showed its increasing intensity, duration and severity of the illness. This indicates an urgent need for effective management and preventive measures in controlling the outbreaks and epidemics. In preventing and spread of epidemic cholera, rapid diagnostic tests (RDTs) are useful in screening suspected stool specimens, water/food samples. Several RDTs developed recently are considered as investigative tools in confirming cholera cases, as the culture techniques are difficult to establish and/or maintain. The usefulness of RDTs will be more at the point-of-care facilities as it helps to make appropriate decisions in the management of outbreaks or epidemiological surveillance by the public health authorities. Apart from RDTs, several other tests are available for the direct detection of either V. cholerae or its cholera toxin. Viable but non-culturable (VBNC) state of V. cholerae poses a great challenge in developing RDTs. The aim of this article is to provide an overview of current knowledge about RDT and other techniques with reference to their status and future potentials in detecting cholera/V. cholerae.
Collapse
Affiliation(s)
| | - Bhabatosh Das
- Translational Health Science and Technology Institute, Faridabad, Haryana, India
| | - Subhra Chakraborty
- Department of International Health Program in Global Disease Epidemiology and Control, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD, USA
| | - Asish K Mukhopadhyay
- Division of Bacteriology, National Institute of Cholera and Enteric Diseases, Kolkata, India
| | - David A Sack
- Department of International Health Program in Global Disease Epidemiology and Control, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD, USA
| |
Collapse
|
7
|
Rapid screening of drug candidates against EGFR/HER2 signaling pathway using fluorescence assay. Anal Bioanal Chem 2018; 410:7827-7835. [DOI: 10.1007/s00216-018-1403-1] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2018] [Revised: 08/24/2018] [Accepted: 09/25/2018] [Indexed: 12/23/2022]
|
8
|
Habimana JDD, Ji J, Sun X. Minireview: Trends in Optical-Based Biosensors for Point-Of-Care Bacterial Pathogen Detection for Food Safety and Clinical Diagnostics. ANAL LETT 2018. [DOI: 10.1080/00032719.2018.1458104] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Affiliation(s)
- Jean de Dieu Habimana
- State Key Laboratory of Food Science and Technology, School of Food Science, National Engineering Research Center for Functional Foods, Synergetic Innovation Center of Food Safety, International Joint Laboratory on Food Safety, Jiangnan University, Wuxi, Jiangsu, China
- Department of Food Science and Technology, School of Food Science and Technology, University of Rwanda, Kigali, Rwanda
| | - Jian Ji
- State Key Laboratory of Food Science and Technology, School of Food Science, National Engineering Research Center for Functional Foods, Synergetic Innovation Center of Food Safety, International Joint Laboratory on Food Safety, Jiangnan University, Wuxi, Jiangsu, China
| | - Xiulan Sun
- State Key Laboratory of Food Science and Technology, School of Food Science, National Engineering Research Center for Functional Foods, Synergetic Innovation Center of Food Safety, International Joint Laboratory on Food Safety, Jiangnan University, Wuxi, Jiangsu, China
| |
Collapse
|
9
|
Vafa M, Khalifeh K, Jafarian V. Negative net charge of EF-hand loop I can affect both calcium sensitivity and substrate binding pattern in mnemiopsin 2. Photochem Photobiol Sci 2018; 17:807-814. [DOI: 10.1039/c8pp00058a] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Mnemiopsin 2 from Mnemiopsis leidy has three Ca2+-binding motifs and has luminescence properties in the presence of calcium and coelenterazine.
Collapse
Affiliation(s)
- Masoomeh Vafa
- Department of Biology
- Faculty of Sciences
- University of Zanjan
- Zanjan
- Iran
| | - Khosrow Khalifeh
- Department of Biology
- Faculty of Sciences
- University of Zanjan
- Zanjan
- Iran
| | - Vahab Jafarian
- Department of Biology
- Faculty of Sciences
- University of Zanjan
- Zanjan
- Iran
| |
Collapse
|
10
|
CdTe quantum dots with green fluorescence generated by bioluminescence resonance energy transfer from aequorin. Mikrochim Acta 2016. [DOI: 10.1007/s00604-016-2057-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
11
|
Hybridoma as a specific, sensitive, and ready to use sensing element: a rapid fluorescence assay for detection of Vibrio cholerae O1. Anal Bioanal Chem 2016; 408:6443-51. [PMID: 27438715 DOI: 10.1007/s00216-016-9762-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2016] [Revised: 06/16/2016] [Accepted: 07/01/2016] [Indexed: 10/21/2022]
Abstract
Over the last decade, isolation and purification of monoclonal antibodies, for diagnostic analysis, have been carried out using the hybridoma expression system. The present study describes a novel example of a detection system using hybridoma cells containing antibody against O1 antigen directly for V. cholerae diagnosis, which is a major health problem in many parts of the world, especially in developing countries. This method has advantages such as simplicity, ease of process, and it does not require manipulation of hybridoma cell. For this approach, an efficient amount of fluorescence calcium indicator, fura 2-AM, was utilized, which emitted light when the intracellular calcium concentration increased as result of antigen binding to specific antibody. More reliable results are obtained via this method and it is considerably faster than other methods, which has the response time of less than 45 s for detection of V. Cholerae O1. Also, the limit of detection was computed to be 50 CFU/mL (<13 CFU per assay). In addition, no significant responses were observed in the presence of other bacteria with specific hybridoma or other cell lines exposed to V. cholerae O1. Furthermore, this method was successfully applied to V. cholerae O1 detection in spiked environmental samples, including water and stool samples without any pretreatment. All results reveal that hybridoma cells can provide a valuable, simple, and ready to use tool for rapid detection of other pathogenic bacteria, toxins, and analytes.
Collapse
|