Wang W, Geng L, Zhang Y, Shen W, Bi M, Gong T, Hu Z, Guo C, Wang T, Sun T. Development of antibody-aptamer sandwich-like immunosensor based on RCA and Nicked-PAM CRISPR/Cas12a system for the ultra-sensitive detection of a biomarker. Anal Chim Acta 2023; 1283:341849. [PMID: 37977804 DOI: 10.1016/j.aca.2023.341849] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2023] [Revised: 09/22/2023] [Accepted: 09/24/2023] [Indexed: 11/19/2023]
Abstract
Biomarkers are the most sensitive reactants and early indicators of many kinds of diseases. The development of highly sensitive and simple techniques to quantify them is challenging. In this study, based on rolling cycle amplification (RCA) and the Nicked PAM/CRISPR-Cas12a system (RNPC) as a signal reporter, a sandwich-type method was developed using antibody@magnetic beads and aptamer for the high-sensitive detection of the C-reactive protein (CRP). The antibody-antigen (target)-aptamer sandwich-like reaction was coupled to RCA, which can produce hundreds of similar binding sites and are discriminated by CRISPR/Cas12a for signal amplification. The ultrasensitivity is achieved based on the dual-signal enhancing strategy, which involves the special recognition of aptamers, RCA, and trans-cleavage of CRISPR/Cas12a. By incorporating the CRISPR/Cas12a system with cleaved PAM, the nonspecific amplification of the RCA reaction alone was greatly reduced, and the dual signal output of RCA and Cas12a improved the detection sensitivity. Our assay can be performed only in two steps. The first step takes only 20 min of target capture, followed by a one-pot reaction, where the target concentration can be obtained by fluorescence values as long as there are 37 °C reaction conditions. Under optimal conditions, this system detected CRP with high sensitivity. The fabricated biosensor showed detection limits of 0.40 pg/mL in phosphate-buffered saline and 0.73 pg/mL in diluted human serum and a broad linear dynamic range of 1.28 pg/mL to 100 ng/mL within a total readout time of 90 min. The method could be used to perform multi-step signal amplification, which can help in the ultrasensitive detection of other proteins. Overall, the proposed biosensor might be used as an immunosensor biosensor platform.
Collapse
Affiliation(s)
- Wen Wang
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin, 300050, PR China; School of Public Health and Management, Binzhou Medical College, Shandong, 264003, PR China
| | - Lu Geng
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin, 300050, PR China
| | - Yiyang Zhang
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin, 300050, PR China
| | - Weili Shen
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin, 300050, PR China
| | - Meng Bi
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin, 300050, PR China
| | - Tingting Gong
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin, 300050, PR China
| | - Zhiyong Hu
- School of Public Health and Management, Binzhou Medical College, Shandong, 264003, PR China
| | - Changjiang Guo
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin, 300050, PR China; School of Public Health and Management, Binzhou Medical College, Shandong, 264003, PR China.
| | - Tianhui Wang
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin, 300050, PR China.
| | - Tieqiang Sun
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin, 300050, PR China.
| |
Collapse
|
2
|
Kokorina AA, Rashchevskaya RO, Goryacheva IY. Nets of biotin-derived gold nanoparticles as a label for the C-reactive protein immunoassay. Anal Bioanal Chem 2021; 413:6867-6875. [PMID: 34559243 DOI: 10.1007/s00216-021-03645-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Revised: 08/25/2021] [Accepted: 09/01/2021] [Indexed: 12/27/2022]
Abstract
This study presents a promising approach for the one-pot generation of the biotin-derived gold nanoparticles (GNPs@biotin). We report a direct method for the reduction of tetrachloroauric acid with biotin and generation of the labels due to nets formed via biotin-streptavidin interactions. The synthesized GNPs@biotin have a characteristic plasmon maximum, excellent colloidal stability, and streptavidin coupling efficiency. The size of the GNPs@biotin:streptavidin nets and the efficiency of interaction with specific antibodies can be easily customized by the component concentrations and time of their interaction. Moreover, the proposed labels require no additional reagents or manipulations for the synthesis, separation, or purification. The developed labels were applied for the detection of the model antigen of C-reactive protein (CRP) as a major inflammation biomarker. The assembling labels demonstrated a competitive advantage limit of CRP detection (LOD) of 1.2 ng/mL and a limit of quantification (LOQ) of 3.9 ng/mL in human plasma comparable to classical immunoassays. Moreover, the proposed approach is universal and can be potentially applied for the quantitative determination of other biomarkers in a variety of immunoassays in a combination with specific biotinylated antibodies.
Collapse
Affiliation(s)
- Alina A Kokorina
- Saratov State University, 83 Astrakhanskaya Street, Saratov, 410012, Russia
| | | | - Irina Yu Goryacheva
- Saratov State University, 83 Astrakhanskaya Street, Saratov, 410012, Russia.
| |
Collapse
|
3
|
Lv Y, Xu H, Wu R, Xu Y, Li N, Li J, Shen H, Ma H, Guo F, Li LS. A quantum dot microspheres-based highly specific and sensitive three-dimensional microarray for multiplexed detection of inflammatory factors. NANOTECHNOLOGY 2021; 32:485101. [PMID: 34371487 DOI: 10.1088/1361-6528/ac1bdd] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Accepted: 08/08/2021] [Indexed: 06/13/2023]
Abstract
The development trend ofin vitrodiagnostics is to obtain various biological information from a sample at extremely low concentration and volume, which has promoted its progress in accurate and sensitive multiplexed detection. Here, we developed a single color quantum dot (QD) based three-dimensional (3D) structure matrix microarray and conducted the detection of two inflammatory factors (C-reactive protein (CRP) and serum amyloid A (SAA)) by a self-built fluorescence detection system. This strategy increased detection sensitivity by immobilizing the antibody specifically on the 3D substrate because it captured more than about 7 times of 'effective' antibodies compared to the two-dimensional (2D) plane. Compared to the dual QDs-2D fluorescence-linked immunosorbent assay, the limit of detection (LOD) of 3D microarray based on QDs modified with amphiphilic polymers has been further improved to 0.11 ng ml-1for SAA assay and to 0.16 ng ml-1for CRP assay, respectively. By using QD microspheres (SiO2@QDs@SiO2-COOH, containing approximately 200-300 hydrophobic QDs on per SiO2sphere) as fluorescent labels, the LOD for CRP and SAA of 3D microarray reached as high as 15 pg ml-1and 86 pg ml-1, and the sensitivity was further improved by 28-fold and 425-fold, respectively. Because of its excellent performance, this QD microspheres-based 3D microarray has great application potential for highly sensitive and multiplexed quantitative detection of other biomarkers, small molecules, and antibiotic residues in biomedicine and food safety.
Collapse
Affiliation(s)
- Yanbing Lv
- Key Lab for Special Functional Materials of Ministry of Education, and School of Materials Science and Engineering, Henan University, Kaifeng, 475004, People's Republic of China
- School of Chemistry, Liaoning University, Shenyang, 110036, People's Republic of China
| | - Hongke Xu
- Division of Nanobiomedicine, Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences, Suzhou, 215123, People's Republic of China
| | - Ruili Wu
- Key Lab for Special Functional Materials of Ministry of Education, and School of Materials Science and Engineering, Henan University, Kaifeng, 475004, People's Republic of China
| | - Yanxia Xu
- Key Lab for Special Functional Materials of Ministry of Education, and School of Materials Science and Engineering, Henan University, Kaifeng, 475004, People's Republic of China
| | - Ning Li
- Key Lab for Special Functional Materials of Ministry of Education, and School of Materials Science and Engineering, Henan University, Kaifeng, 475004, People's Republic of China
| | - Jinjie Li
- Key Lab for Special Functional Materials of Ministry of Education, and School of Materials Science and Engineering, Henan University, Kaifeng, 475004, People's Republic of China
| | - Huaibin Shen
- Key Lab for Special Functional Materials of Ministry of Education, and School of Materials Science and Engineering, Henan University, Kaifeng, 475004, People's Republic of China
| | - Hongwei Ma
- Division of Nanobiomedicine, Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences, Suzhou, 215123, People's Republic of China
| | - Fang Guo
- School of Chemistry, Liaoning University, Shenyang, 110036, People's Republic of China
| | - Lin Song Li
- Key Lab for Special Functional Materials of Ministry of Education, and School of Materials Science and Engineering, Henan University, Kaifeng, 475004, People's Republic of China
| |
Collapse
|
4
|
Dhamane S, Patil U, Smith M, Adhikari M, Nazem A, Conrad JC, Kourentzi K, Willson RC. Isocratic reporter-exclusion immunoassay using restricted-access adsorbents. Analyst 2021; 146:4835-4840. [PMID: 34198311 PMCID: PMC9798887 DOI: 10.1039/d1an00396h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
We introduce analyte-dependent exclusion of reporter reagents from restricted-access adsorbents as the basis of an isocratic reporter-exclusion immunoassay for viruses, proteins, and other analytes. Capto™ Core 700 and related resins possess a noninteracting size-selective outer layer surrounding a high-capacity nonspecific mixed-mode capture adsorbent core. In the absence of analyte, antibody-enzyme reporter conjugates can enter the adsorbent and be captured, and their signal is lost. In the presence of large or artificially-expanded analytes, reporter reagents bind to analyte species to form complexes large enough to be excluded from the adsorbent core, allowing their signal to be observed. This assay principle is demonstrated using M13 bacteriophage virus and human chorionic gonadotropin as model analytes. The simple isocratic detection approach described here allows a rapid implementation of immunoassay for detection of a wide range of analytes and uses inexpensive, generally-applicable, and stable column materials instead of costly analyte-specific immunoaffinity adsorbents.
Collapse
Affiliation(s)
- Sagar Dhamane
- Department of Biology and Biochemistry, University of Houston, Houston, TX USA
| | - Ujwal Patil
- Department of Biology and Biochemistry, University of Houston, Houston, TX USA
| | - Maxwell Smith
- Department of Chemical and Biomolecular Engineering, University of Houston, TX USA
| | - Meena Adhikari
- Department of Biology and Biochemistry, University of Houston, Houston, TX USA
| | - Ahmad Nazem
- Department of Biomedical Engineering, University of Houston, Houston, TX USA
| | - Jacinta C. Conrad
- Department of Chemical and Biomolecular Engineering, University of Houston, TX USA
| | - Katerina Kourentzi
- Department of Chemical and Biomolecular Engineering, University of Houston, TX USA
| | - Richard C. Willson
- Department of Biology and Biochemistry, University of Houston, Houston, TX USA,Department of Biomedical Engineering, University of Houston, Houston, TX USA,Department of Chemical and Biomolecular Engineering, University of Houston, TX USA,Escuela de Medicina y Ciencias de las Salud ITESM, Monterrey, Mexico,Corresponding author. (Richard C. Willson)
| |
Collapse
|
5
|
Kokorina AA, Ponomaryova TS, Goryacheva IY. Photoluminescence-based immunochemical methods for determination of C-reactive protein and procalcitonin. Talanta 2021; 224:121837. [PMID: 33379055 DOI: 10.1016/j.talanta.2020.121837] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2020] [Revised: 10/26/2020] [Accepted: 10/28/2020] [Indexed: 12/16/2022]
Abstract
Modern, sensitive, rapid, and selective analytical methods for the detection of inflammatory markers are a crucial tool for the assessment of inflammation state, efficacy of medical intervention, and the prediction of future diseases. Their development requires understanding of current state for point-of-care testing of inflammatory markers and identification of their crucial drawbacks. This review summarizes the progress in the application of luminescent labels for immunoassays. The luminescent labels became more popular in the latest decade due to their high sensitivity, selectivity, and robustness. This review presents a constructive analysis of different luminescent labels such as fluorescent organic dyes, quantum dots, long-lived emissive nanoparticles, and up-converting nanocrystals, as well as a range of the strategies for inflammatory markers determination. The advantages and disadvantages of all classes of luminescent labels are demonstrated, and the strategies of labels modification for their improvement are discussed. The current approaches for the creation of luminescent probes and robust assays are also highlighted.
Collapse
Affiliation(s)
- Alina A Kokorina
- Saratov State University, Astrakhanskaya Street 83, 410012, Saratov, Russia.
| | | | | |
Collapse
|
6
|
Liu Z, Zhang Y, Li B, Ren X, Ma H, Wei Q. Novel ratiometric electrochemical sensor for no-wash detection of fluorene-9-bisphenol based on combining CoN nanoarrays with molecularly imprinted polymers. Analyst 2020; 145:3320-3328. [PMID: 32202270 DOI: 10.1039/d0an00345j] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
No-wash detection of small molecules in real samples has been attracting attention in the field of sensors including electroanalytical biosensors. Based on the direct electrochemical oxidation of fluorene-9-bisphenol (BHPF) on a CoN nanoarray electrode, we developed a ratiometric molecularly imprinted polymeric electrochemical (MIP-EC) sensor to realize no-wash detection of BHPF in serum and tap water. The CoN nanoarray in situ grown on carbon cloth (CC) served as the working electrode, which could load the electroactive toluidine blue (TB) and be modified by the MIPs. As the MIP concentration on the modified electrode surface was increased, the amount of BHPF exposed on the electrode surface increased and the amount of exposed TB decreased. Thus, the values of ΔITB and ΔIBHPF decreased and increased, respectively, with an increasing amount of BHPF. Therefore, a ratiometric strategy was established by using the value of ΔITB/ΔIBHPF as the instruction response to realize detection of BHPF with high sensitivity and reliability. The developed ratiometric MIP-EC sensor showed strong anti-interference ability, good detection reproducibility and stability towards no-wash detection of BHPF as shown from tests with real samples. This work can further provide theoretical and practical guidance for the detection of other familiar small molecules.
Collapse
Affiliation(s)
- Zhaoyi Liu
- Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P.R. China.
| | | | | | | | | | | |
Collapse
|
7
|
Molinero-Fernández Á, Arruza L, López MÁ, Escarpa A. On-the-fly rapid immunoassay for neonatal sepsis diagnosis: C-reactive protein accurate determination using magnetic graphene-based micromotors. Biosens Bioelectron 2020; 158:112156. [PMID: 32275206 DOI: 10.1016/j.bios.2020.112156] [Citation(s) in RCA: 39] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2019] [Revised: 03/05/2020] [Accepted: 03/15/2020] [Indexed: 01/19/2023]
Abstract
Based on the exceptional and new opened biosensing possibilities of self-propelled micromotors, a micromotor-based immunoassay (MIm) has smartly been designed for C-reactive protein (CRP) determination in plasma of preterm infants with sepsis suspicion. The design of the micromotors involved the electrosynthesis of a carbon-based outer layer (for antibody functionalization), an intermediate Ni layer (for magnetic guidance and stopped flow operations) and PtNPs inner catalytic layer (for catalytic bubble propulsion). Micromotors biofunctionalization on the outer layer (using carbon black (CB), reduced graphene oxide (rGO) and multi-walled carbon nanotubes (MWCNTs), and biocompatible propulsion capabilities, were carefully studied. Magnetic rGO/Ni/PtNPs micromotors exhibited the most efficient and reproducible (CV = 9%) anti-CRP functionalization, controlled stopped-flow operations as well as efficient bubble propulsion (1% H2O2, 1,5% NaCh, speed 140 μm s-1). Analytical performance of MIm was excellent, allowing the direct (without dilution), sensitive (LOD = 0.80 μg/mL), and accurate CRP determination (Er = 1%) in hardly available preterm babies' plasma samples with suspected sepsis using very low volumes (<10 μL) and in just 5 min of on-the-fly bioassay. Overall, the results obtained allowed the fast and reliable sepsis diagnostics in preterm babies' individuals with suspected sepsis, not only proving the usefulness of the approach as its potential utilization as point-of-care device for clinical analysis but drawing new horizons in extremely low sample volumes-based diagnostics.
Collapse
Affiliation(s)
- Águeda Molinero-Fernández
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, University of Alcala, Ctra. Madrid-Barcelona, Km. 33.600, 28871, Alcalá de Henares, Madrid, Spain
| | - Luis Arruza
- Division of Neonatology, Child and Teenager Institute, San Carlos Clinic Hospital-IdISSC, Madrid, Spain
| | - Miguel Ángel López
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, University of Alcala, Ctra. Madrid-Barcelona, Km. 33.600, 28871, Alcalá de Henares, Madrid, Spain; Chemical Research Institute "Andres M. Del Rio", University of Alcala, Madrid, Spain.
| | - Alberto Escarpa
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, University of Alcala, Ctra. Madrid-Barcelona, Km. 33.600, 28871, Alcalá de Henares, Madrid, Spain; Chemical Research Institute "Andres M. Del Rio", University of Alcala, Madrid, Spain.
| |
Collapse
|
8
|
|
9
|
Ran B, Zheng W, Dong M, Xianyu Y, Chen Y, Wu J, Qian Z, Jiang X. Peptide-Mediated Controllable Cross-Linking of Gold Nanoparticles for Immunoassays with Tunable Detection Range. Anal Chem 2018; 90:8234-8240. [PMID: 29874048 DOI: 10.1021/acs.analchem.8b01760] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Affiliation(s)
- Bei Ran
- State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University and Collaborative Innovation Center, Chengdu, Sichuan 610041, People’s Republic of China
- Beijing Engineering Research Center for BioNanotechnology and CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, CAS Center for Excellence in Nanoscience, National Center for NanoScience and Technology, No. 11 Zhongguancun Beiyitiao, Beijing 100190, People’s Republic of China
| | - Wenshu Zheng
- Beijing Engineering Research Center for BioNanotechnology and CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, CAS Center for Excellence in Nanoscience, National Center for NanoScience and Technology, No. 11 Zhongguancun Beiyitiao, Beijing 100190, People’s Republic of China
| | - Mingling Dong
- State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University and Collaborative Innovation Center, Chengdu, Sichuan 610041, People’s Republic of China
- Beijing Engineering Research Center for BioNanotechnology and CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, CAS Center for Excellence in Nanoscience, National Center for NanoScience and Technology, No. 11 Zhongguancun Beiyitiao, Beijing 100190, People’s Republic of China
| | - Yunlei Xianyu
- Beijing Engineering Research Center for BioNanotechnology and CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, CAS Center for Excellence in Nanoscience, National Center for NanoScience and Technology, No. 11 Zhongguancun Beiyitiao, Beijing 100190, People’s Republic of China
| | - Yiping Chen
- Beijing Engineering Research Center for BioNanotechnology and CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, CAS Center for Excellence in Nanoscience, National Center for NanoScience and Technology, No. 11 Zhongguancun Beiyitiao, Beijing 100190, People’s Republic of China
| | - Jing Wu
- Beijing Engineering Research Center for BioNanotechnology and CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, CAS Center for Excellence in Nanoscience, National Center for NanoScience and Technology, No. 11 Zhongguancun Beiyitiao, Beijing 100190, People’s Republic of China
| | - Zhiyong Qian
- State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University and Collaborative Innovation Center, Chengdu, Sichuan 610041, People’s Republic of China
| | - Xingyu Jiang
- Beijing Engineering Research Center for BioNanotechnology and CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, CAS Center for Excellence in Nanoscience, National Center for NanoScience and Technology, No. 11 Zhongguancun Beiyitiao, Beijing 100190, People’s Republic of China
- The University of Chinese Academy of Sciences, 19 A Yuquan Road, Shijingshan District, Beijing, 100049, People’s Republic of China
| |
Collapse
|
10
|
Recent advances in biosensor technology in assessment of early diabetes biomarkers. Biosens Bioelectron 2018; 99:122-135. [DOI: 10.1016/j.bios.2017.07.047] [Citation(s) in RCA: 74] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2017] [Revised: 07/17/2017] [Accepted: 07/18/2017] [Indexed: 01/26/2023]
|
11
|
Broto M, Galve R, Marco MP. Sandwich NP-based biobarcode assay for quantification C-reactive protein in plasma samples. Anal Chim Acta 2017; 992:112-118. [PMID: 29054144 DOI: 10.1016/j.aca.2017.09.007] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2017] [Revised: 08/29/2017] [Accepted: 09/01/2017] [Indexed: 12/20/2022]
Abstract
A NP-based biobarcode for C-reactive protein (CRP) quantification in plasma samples is reported for the first time. The assay uses capture antibody functionalized magnetic beads (pAbCRP2-MP), multifunctional oligonucleotide encoded probes modified with a detection antibody (pAbCRP1-ePSP), and a fluorescent DNA microarray. Thus, magnetic beads are added to the sample to form immunocomplexes that will be isolated, to then add the codified particles to form a sandwich complex with both particles and the target protein, subsequently the complexes are treated to release the oligonucleotide codes, which are finally hybridized in a fluorescent DNA microarray. The assay has been implemented to the analysis of plasma samples being able to quantify this biomarker within 900 ng mL-1 to 12500 ng mL-1 with an excellent accuracy (mean of recovery of 99.5 ± 4.2%, N = 3). The CRP biobarcode has been used on a small pilot clinical study in which plasma samples from patients suffering different pathologies, most of them related to cardiovascular diseases (CVDs). The samples have been analyzed and the results compared to a reference method demonstrating that the assay can be useful for monitoring this biomarker on patients being suspicious to be under risk of suffering CVDs or other diseases involving inflammatory processes.
Collapse
Affiliation(s)
- Marta Broto
- Nanobiotechnology for Diagnostics (Nb4D), Department of Chemical and Biomolecular Nanotechnology, Institute for Advanced Chemistry of Catalonia (IQAC) of the Spanish Council for Scientific Research (CSIC), Jordi Girona 18-26, 08034 Barcelona, Spain; CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Jordi Girona 18-26, 08034 Barcelona, Spain
| | - Roger Galve
- Nanobiotechnology for Diagnostics (Nb4D), Department of Chemical and Biomolecular Nanotechnology, Institute for Advanced Chemistry of Catalonia (IQAC) of the Spanish Council for Scientific Research (CSIC), Jordi Girona 18-26, 08034 Barcelona, Spain; CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Jordi Girona 18-26, 08034 Barcelona, Spain.
| | - M-Pilar Marco
- Nanobiotechnology for Diagnostics (Nb4D), Department of Chemical and Biomolecular Nanotechnology, Institute for Advanced Chemistry of Catalonia (IQAC) of the Spanish Council for Scientific Research (CSIC), Jordi Girona 18-26, 08034 Barcelona, Spain; CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Jordi Girona 18-26, 08034 Barcelona, Spain
| |
Collapse
|