1
|
Jiang M, Wang A, Sun Y, Li Y, Chen Y, Zhou J, Liu H, Ding P, Qi Y, Li N, Zhang G. Development of a Gold Nanoparticle-Based Immunochromatographic Strip for Rapid Detection of Porcine Circovirus Type 2. Microbiol Spectr 2023; 11:e0195322. [PMID: 37466437 PMCID: PMC10434270 DOI: 10.1128/spectrum.01953-22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Accepted: 05/15/2023] [Indexed: 07/20/2023] Open
Abstract
Porcine circovirus type 2 (PCV2) is an important swine infectious pathogen that seriously threatens the global swine industry. PCV2 Cap protein is the only structural and the main immunogenic protein constituting the viral capsid. In this study, a gold nanoparticle-based immunochromatographic strip with high sensitivity and specificity was developed which could be used for rapid detection of PCV2 virions or Cap protein in research. The visual detection limit of the strip was 103.18 50% tissue culture infective does (TCID50)/mL for PCV2, and 2.03 μg/mL for PCV2 Cap protein. No cross-reactivity was observed with the PCV1 and PCV3 Cap proteins and other common swine pathogens such as porcine reproductive and respiratory syndrome virus, classical swine fever virus, pseudorabies virus, porcine epidemic diarrhea virus, porcine parvovirus, and swine influenza virus. The repeatability of the strip was good. The stability of the strip was perfect for 12 months in a dry state at room temperature. Visual results could be obtained within 5 min by simply inserting the strip into the diluted sample. The strip is a time-saving, labor-saving, and reliable tool for testing of PCV2 virions or Cap protein in research. The idea of this study might open a new perspective for the application of the strip. IMPORTANCE Porcine circovirus type 2 (PCV2) Cap protein is the only structural and the main immunogenic protein constituting the viral capsid. Although many methods can be used to identify PCV2 or PCV2 Cap protein in vaccine research, they usually require high workload and time. The developed strip can specifically detect PCV2 virions or Cap protein, and visual qualitative results can be obtained within 5 min by simply diluting the sample and inserting the strip into the sample. The final value of the strip is providing a simple and time-saving method for real-time monitoring of PCV2 antigen in vaccine research with reliable results, such as the different stages of PCV2 Cap protein expression and purification, as well as the different stages of PCV2 reproduction and purification.
Collapse
Affiliation(s)
- Min Jiang
- Longhu Laboratory of Advanced Immunology, Zhengzhou, Henan, China
- School of Life Sciences, Zhengzhou University, Zhengzhou, Henan, China
- Henan Provincial Key Laboratory of Immunobiology, Zhengzhou, China
| | - Aiping Wang
- Longhu Laboratory of Advanced Immunology, Zhengzhou, Henan, China
- School of Life Sciences, Zhengzhou University, Zhengzhou, Henan, China
- Henan Agricultural University, Zhengzhou, Henan, China
- Henan Provincial Key Laboratory of Immunobiology, Zhengzhou, China
| | - Yaning Sun
- Longhu Laboratory of Advanced Immunology, Zhengzhou, Henan, China
| | - Yuan Li
- School of Life Sciences, Lanzhou University, Lanzhou, Gansu, China
| | - Yumei Chen
- Longhu Laboratory of Advanced Immunology, Zhengzhou, Henan, China
- School of Life Sciences, Zhengzhou University, Zhengzhou, Henan, China
- Henan Provincial Key Laboratory of Immunobiology, Zhengzhou, China
| | - Jingming Zhou
- Longhu Laboratory of Advanced Immunology, Zhengzhou, Henan, China
- School of Life Sciences, Zhengzhou University, Zhengzhou, Henan, China
- Henan Provincial Key Laboratory of Immunobiology, Zhengzhou, China
| | - Hongliang Liu
- Longhu Laboratory of Advanced Immunology, Zhengzhou, Henan, China
- School of Life Sciences, Zhengzhou University, Zhengzhou, Henan, China
- Henan Provincial Key Laboratory of Immunobiology, Zhengzhou, China
| | - Peiyang Ding
- Longhu Laboratory of Advanced Immunology, Zhengzhou, Henan, China
- School of Life Sciences, Zhengzhou University, Zhengzhou, Henan, China
- Henan Provincial Key Laboratory of Immunobiology, Zhengzhou, China
| | - Yanhua Qi
- Longhu Laboratory of Advanced Immunology, Zhengzhou, Henan, China
- School of Life Sciences, Zhengzhou University, Zhengzhou, Henan, China
- Henan Provincial Key Laboratory of Immunobiology, Zhengzhou, China
| | - Ning Li
- Longhu Laboratory of Advanced Immunology, Zhengzhou, Henan, China
| | - Gaiping Zhang
- Longhu Laboratory of Advanced Immunology, Zhengzhou, Henan, China
- School of Life Sciences, Zhengzhou University, Zhengzhou, Henan, China
- School of Advanced Agricultural Sciences, Peking University, Beijing, China
- Henan Agricultural University, Zhengzhou, Henan, China
- Henan Provincial Key Laboratory of Immunobiology, Zhengzhou, China
| |
Collapse
|
2
|
Point-of-Care Diagnostics for Farm Animal Diseases: From Biosensors to Integrated Lab-on-Chip Devices. BIOSENSORS 2022; 12:bios12070455. [PMID: 35884258 PMCID: PMC9312888 DOI: 10.3390/bios12070455] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Revised: 06/22/2022] [Accepted: 06/23/2022] [Indexed: 02/06/2023]
Abstract
Zoonoses and animal diseases threaten human health and livestock biosecurity and productivity. Currently, laboratory confirmation of animal disease outbreaks requires centralized laboratories and trained personnel; it is expensive and time-consuming, and it often does not coincide with the onset or progress of diseases. Point-of-care (POC) diagnostics are rapid, simple, and cost-effective devices and tests, that can be directly applied on field for the detection of animal pathogens. The development of POC diagnostics for use in human medicine has displayed remarkable progress. Nevertheless, animal POC testing has not yet unfolded its full potential. POC devices and tests for animal diseases face many challenges, such as insufficient validation, simplicity, and portability. Emerging technologies and advanced materials are expected to overcome some of these challenges and could popularize animal POC testing. This review aims to: (i) present the main concepts and formats of POC devices and tests, such as lateral flow assays and lab-on-chip devices; (ii) summarize the mode of operation and recent advances in biosensor and POC devices for the detection of farm animal diseases; (iii) present some of the regulatory aspects of POC commercialization in the EU, USA, and Japan; and (iv) summarize the challenges and future perspectives of animal POC testing.
Collapse
|
3
|
Lin TL, Cheng C, Zeng WT, Duan F, Pei YH, Liu XP, Shang F, Wu KL. Anti-viral activity of Staphylococcus aureus lysates against herpes simplex virus type-I infection: an in vitro and in vivo study. Int J Ophthalmol 2021; 14:1463-1472. [PMID: 34667721 DOI: 10.18240/ijo.2021.10.01] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2020] [Accepted: 02/05/2021] [Indexed: 02/08/2023] Open
Abstract
AIM To investigate the effect of Staphylococcus aureus (S. aures) lysates (SALs) on herpes simplex virus type-I (HSV1) infection in human corneal epithelial (HCE) cells and in a mouse model of HSV1 keratitis. METHODS HCE, Vero, HeLa, and BV2 cells were infected with HSV1 [HSV1 f strain, HSV1f; HSV-1-H129 with green fluorescent protein (GFP) knock-in, HSV1g]. Pre- or post-infection, SAL at various concentrations was added to the culture medium for 24h. GFP fluorescence in HSV1g or plaque formation by HSV1f were examined. The effects of heat-treated SAL, precooled acetone-precipitated SAL, and SAL subjected to ultrafiltration (100 kDa) were evaluated. The effects of other bacterial components and lysates on HSV1 infection were also tested, including lipoteichoic acid (LTA), peptidoglycan (PGN), staphylococcal protein A (SPA), and α-hemolysin from S. aureus (α-toxin) as well as lysates from a wild-type S. aureus strain, S. epidermidis, and Escherichia coli (W-SAL, SEL, and ECL, respectively). In addition, SAL eye drops were applied topically to BALB/c mice with HSV1 keratitis, followed by in vivo observations. RESULTS The cytopathic effect, plaque formation (HSV1f), and GFP expression (HSV1g) in infected cells were inhibited by SAL in a dose-dependent manner. The active component of SAL (≥100 kDa) was heat-sensitive and retained activity after acetone precipitation. In HSV1g-infected cells, treatment with LTA-sa, α-toxin, PGN-sa, or SPA did not inhibit GFP expression. SAL, W-SAL, and SEL (but not ECL) decreased GFP expression. In mice with HSV1 keratitis, SAL reduced corneal lesions by 71%. CONCLUSION The results of this study demonstrate that SAL can be used to inhibit HSV1 infection, particularly keratitis. Further studies are needed to determine the active components and mechanism underlying the effects of SAL.
Collapse
Affiliation(s)
- Tian-Lan Lin
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Sun Yat-sen University, Guangzhou 510060, Guangdong Province, China
| | - Chao Cheng
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Sun Yat-sen University, Guangzhou 510060, Guangdong Province, China
| | - Wei-Ting Zeng
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Sun Yat-sen University, Guangzhou 510060, Guangdong Province, China
| | - Fang Duan
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Sun Yat-sen University, Guangzhou 510060, Guangdong Province, China
| | - Yin-Hui Pei
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Sun Yat-sen University, Guangzhou 510060, Guangdong Province, China
| | - Xiu-Ping Liu
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Sun Yat-sen University, Guangzhou 510060, Guangdong Province, China
| | - Fu Shang
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Sun Yat-sen University, Guangzhou 510060, Guangdong Province, China
| | - Kai-Li Wu
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Sun Yat-sen University, Guangzhou 510060, Guangdong Province, China
| |
Collapse
|
4
|
Klangprapan S, Weng CC, Huang WT, Li YK, Choowongkomon K. Selection and Characterization of a Single-Chain Variable Fragment against Porcine Circovirus Type 2 Capsid and Impedimetric Immunosensor Development. ACS OMEGA 2021; 6:24233-24243. [PMID: 34568701 PMCID: PMC8459408 DOI: 10.1021/acsomega.1c03894] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/22/2021] [Indexed: 06/13/2023]
Abstract
Porcine circovirus type 2 (PCV2) is the primary causative agent of porcine circovirus-associated disease (PCVAD) that causes huge global economic losses for the swine industry. Effective strategies or rapid detection of PCV2 in pig are essential to control PCVAD. Here, single-chain variable fragments (scFvs) were selected and characterized against the PCV2 capsid using phage display technology. Phage scFv clones were selected from the human scFv phagemid library (Tomlinson I + J) for direct panning against the PCV2 capsid. Eighty-four monoclonal phage scFvs were individually tested for binding to the PCV2 capsid by ELISA. Eight scFv clones showed significant binding to the PCV2 capsid and only three clones (clone nos. 13, 37, and 81) contained both VHCDRs and VLCDRs in the sequence. Clone scFv no. 81 had the highest reactivity to the PCV2 capsid and was constructed in the pET22b (+) expression vector. The recombinant was transformed to Escherichia coli BL21(DE3) for expression and purification. The scFv showed appropriate affinity to the PCV2 capsid by western blot analysis. Kinetics of scFv and the PCV2 capsid were determined using surface plasmon resonance and showed binding affinity in the nanomolar range (K D = 57.2 nM). Our scFv was first applied in the development of an impedimetric immunosensor for PCV2 capsid detection, and results showed that impedance increased with increasing PCV2 capsid expression with limit of detection = 114 nM. Findings demonstrated that our scFv has potential for use as a receptor for biosensor devices.
Collapse
Affiliation(s)
- Supaporn Klangprapan
- Genetic Engineering Interdisciplinary Program, Graduate School, Kasetsart University, 50 Ngam Wong Wan Road, Chatuchak, Bangkok 10900, Thailand
| | - Chang-Ching Weng
- Department of Applied Chemistry, National Chiao Tung University, 1001 University Road, Hsinchu 30010, Taiwan
| | - Wan-Ting Huang
- Department of Applied Chemistry, National Chiao Tung University, 1001 University Road, Hsinchu 30010, Taiwan
| | - Yaw-Kuen Li
- Department of Applied Chemistry, National Chiao Tung University, 1001 University Road, Hsinchu 30010, Taiwan
- Center for Emergent Functional Matter Science, National Chiao Tung University, 1001 University Road, Hsinchu 30010, Taiwan
| | - Kiattawee Choowongkomon
- Department of Biochemistry, Faculty of Science, Kasetsart University, 50 Ngam Wong Wan Road, Chatuchak, Bangkok 10900, Thailand
| |
Collapse
|
5
|
Zhao N, Lin Q, Yao K, Zhang F, Tian B, Chen F, Jiang Z. Simultaneous Measurement of Temperature and Refractive Index Using High Temperature Resistant Pure Quartz Grating Based on Femtosecond Laser and HF Etching. MATERIALS 2021; 14:ma14041028. [PMID: 33671573 PMCID: PMC7926831 DOI: 10.3390/ma14041028] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/29/2020] [Revised: 02/13/2021] [Accepted: 02/18/2021] [Indexed: 11/16/2022]
Abstract
The optical fiber temperature and refractive index sensor combined with the hollow needle structure for medical treatment can promote the standardization of traditional acupuncture techniques and improve the accuracy of body fluid analysis. A double-parameter sensor based on fiber Bragg grating (FBG) is developed in this paper. The sensor materials are selected through X-ray diffraction (XRD) analysis, and the sensor sensing principle is theoretically analyzed and simulated. Through femtosecond laser writing pure silica fiber, a high temperature resistant wavelength type FBG temperature sensor is obtained, and the FBG is corroded by hydrofluoric acid (HF) to realize a high-sensitivity intensity-type refractive index sensor. Because the light has dual characteristics of energy and wavelength, the sensor can realize simultaneous dual-parameter sensing. The light from the lead-in optical fiber is transmitted to the sensor and affected by temperature and refractive-index; then, the reflection peak is reflected back to the lead-out fiber by the FBG. The high temperature response and the refractive index response of the sensor were measured in the laboratory, and the high temperature characteristics of the sensor were verified in the accredited institute. It is demonstrated that the proposed sensor can achieve temperature sensing up to 1150 °C with the sensitivity of 0.0134 nm/°C, and refractive sensing over a refractive range of 1.333 to 1.4027 with the sensitivity of -49.044 dBm/RIU. The sensor features the advantages of two-parameter measurement, compact structure, and wide temperature range, and it exhibits great potential in acupuncture treatment.
Collapse
Affiliation(s)
- Na Zhao
- State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an 710049, China; (N.Z.); (K.Y.); (F.Z.); (B.T.); (F.C.); (Z.J.)
| | - Qijing Lin
- State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an 710049, China; (N.Z.); (K.Y.); (F.Z.); (B.T.); (F.C.); (Z.J.)
- Collaborative Innovation Center of High-End Manufacturing Equipment, Xi’an Jiaotong University, Xi’an 710054, China
- Correspondence:
| | - Kun Yao
- State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an 710049, China; (N.Z.); (K.Y.); (F.Z.); (B.T.); (F.C.); (Z.J.)
| | - Fuzheng Zhang
- State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an 710049, China; (N.Z.); (K.Y.); (F.Z.); (B.T.); (F.C.); (Z.J.)
| | - Bian Tian
- State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an 710049, China; (N.Z.); (K.Y.); (F.Z.); (B.T.); (F.C.); (Z.J.)
| | - Feng Chen
- State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an 710049, China; (N.Z.); (K.Y.); (F.Z.); (B.T.); (F.C.); (Z.J.)
| | - Zhuangde Jiang
- State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an 710049, China; (N.Z.); (K.Y.); (F.Z.); (B.T.); (F.C.); (Z.J.)
| |
Collapse
|
6
|
Synthesis and Surface Modification of Nanostructured F-Doped ZnO: Toward a Transducer for Label-Free Optical Biosensing. APPLIED SCIENCES-BASEL 2019. [DOI: 10.3390/app9163380] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
In this work, the surface of nanostructured fluorine-doped ZnO (nZnO·F) is functionalized with protein A (PrA), and used as a model biomolecule. The chemical procedure is characterized by several analytical techniques such as Fourier Transform Infrared Spectroscopy, water contact angle analysis, and fluorescence microscopy. The surface modification of nZnO·F by binding increasing concentrations of PrA is also investigated by two label-free optical techniques, i.e., the spectroscopic reflectometry and the steady-state photoluminescence. The results are compared with those obtained using undoped nZnO substrates in order to highlight the better performances of nZnO·F due to the fluorine doping. The results of this study pave the way for the design and realization of a ZnO-based nanostructured platform for label-free optical sensing.
Collapse
|
7
|
Recent development of fiber-optic chemical sensors and biosensors: Mechanisms, materials, micro/nano-fabrications and applications. Coord Chem Rev 2018. [DOI: 10.1016/j.ccr.2018.08.001] [Citation(s) in RCA: 133] [Impact Index Per Article: 22.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
8
|
Du X, Zhou J. Application of biosensors to detection of epidemic diseases in animals. Res Vet Sci 2018; 118:444-448. [PMID: 29730246 DOI: 10.1016/j.rvsc.2018.04.011] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2017] [Revised: 04/26/2018] [Accepted: 04/26/2018] [Indexed: 12/31/2022]
Abstract
Epidemic diseases are the leading cause of animal mortality, resulting in significant losses to the agricultural economy. These economic impacts have generated a strong interest in advancing methods for the diagnosis and control of epidemic diseases in animals. Conventional methods are often time-consuming (typically result is available in 2-10 days), expensive, and require both large-scale equipment and experienced personnel. However, the advent of biosensor technology has ushered in a new and promising approach for the diagnosis of animal diseases. With advantages that include simplicity, real -time analysis, high sensitivity, miniaturization, rapid detection time, and low cost, biosensor technologies are under active development for the diagnosis of epidemic diseases in animals. Here, we summarize recent developments in biological sensing technologies used to detect infectious viral, bacterial, and parasitic diseases. Additionally, we discuss research challenges and future prospects for this field of study.
Collapse
Affiliation(s)
- Xin Du
- Institute of Biomedical Sciences, College of Life Sciences, Key Laboratory of Animal Resistance Biology of Shandong Province, Shandong Normal University, Jinan 250014, China..
| | - Jun Zhou
- Institute of Biomedical Sciences, College of Life Sciences, Key Laboratory of Animal Resistance Biology of Shandong Province, Shandong Normal University, Jinan 250014, China
| |
Collapse
|
9
|
Lu H, Luo B, Shi S, Zhao M, Lu J, Ye L, Zhong N, Tang B, Wang X, Wang Y. Study on spectral and refractive index sensing characteristics of etched excessively tilted fiber gratings. APPLIED OPTICS 2018; 57:2590-2596. [PMID: 29714245 DOI: 10.1364/ao.57.002590] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/08/2018] [Accepted: 03/01/2018] [Indexed: 06/08/2023]
Abstract
We investigated the spectral and refractive index (RI) sensing characteristics of the excessively tilted fiber grating (Ex-TFG) with different cladding diameters. The Ex-TFG is inscribed in standard single-mode fiber, and the cladding reduces from 125 μm to around 15 μm by the chemical etching method. Experimental results show that the number of cladding modes decreases, and the spacing of adjacent resonance peaks becomes larger and larger with the reduction of the cladding diameter in the observed wavelength range of 1250-1650 nm. The average RI sensitivity in the index region of 1.33-1.38, the one near 1.33, and the one at around 1.38 of the etched Ex-TFG with a diameter of 15 μm is ∼6.3, ∼5.3, and ∼6.67 fold compared to those of the no-etched Ex-TFG, respectively. Also, the RI sensing performances of the etched Ex-TFG with a diameter smaller than 30 μm are better than those of the Ex-TFG inscribed in SM1500 (4.2 μm/80 μm) fiber in the index region of 1.33. The proposed micronano Ex-TFG has higher RI sensitivity and a more compact structure in biosensing applications, compared to the standard Ex-TFGs and Ex-TFGs inscribed in SM1500 fiber.
Collapse
|
10
|
Luo B, Xu Y, Wu S, Zhao M, Jiang P, Shi S, Zhang Z, Wang Y, Wang L, Liu Y. A novel immunosensor based on excessively tilted fiber grating coated with gold nanospheres improves the detection limit of Newcastle disease virus. Biosens Bioelectron 2017; 100:169-175. [PMID: 28888179 DOI: 10.1016/j.bios.2017.08.064] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2017] [Revised: 08/18/2017] [Accepted: 08/30/2017] [Indexed: 12/22/2022]
Abstract
A novel immunosensor for detecting Newcastle disease virus (NDV) was developed using excessively tilted fiber grating (Ex-TFG) coated with gold nanospheres (AuNs). AuNs were coated on the Ex-TFG surface via Au-S bonds using 3-mercaptopropyltrimethoxysilane (MPTMS), and the activated staphylococcal protein A (SPA) was linked to AuNs by covalent bonds via cysteamine. AuNs greatly enhanced the impact of the analyte on the fiber cladding mode through the local surface Plasmon resonance (LSPR) effect, thus improving the detection limit and sensitivity of the immunosensor. Meanwhile, SPA enhanced the bioactivity of anti-NDV monoclonal antibodies (MAbs), thus promoting the effectiveness of specific binding events on the fiber surface. Immunoassays were performed by monitoring the resonance wavelength shift of the proposed sensor under NDV samples containing different particle amounts. Specificity was assessed, and clinical tests for NDV were performed by contrast experiments. Experimental results showed that the detection limit for NDV was about 5~10 times improved compared to that of reference Ex-TFG without AuN treatment. Moreover, the novel biosensor was reusable and could potentially be applied in clinic.
Collapse
Affiliation(s)
- Binbin Luo
- Chongqing Key Laboratory of Optical Fiber Sensor and Photoelectric Detection, Chongqing University of Technology, Chongqing 400054, China; School of Opto-electronic Information, University of Electronic Science and Technology of China, Chengdu 610054, China
| | - Yangfei Xu
- Chongqing Key Laboratory of Optical Fiber Sensor and Photoelectric Detection, Chongqing University of Technology, Chongqing 400054, China
| | - Shengxi Wu
- School of Pharmacy and Bioengineering, Chongqing University of Technology, Chongqing 400054, China.
| | - Mingfu Zhao
- Chongqing Key Laboratory of Optical Fiber Sensor and Photoelectric Detection, Chongqing University of Technology, Chongqing 400054, China
| | - Pengjun Jiang
- School of Pharmacy and Bioengineering, Chongqing University of Technology, Chongqing 400054, China
| | - Shenghui Shi
- Chongqing Key Laboratory of Optical Fiber Sensor and Photoelectric Detection, Chongqing University of Technology, Chongqing 400054, China
| | - Zhonghao Zhang
- School of Pharmacy and Bioengineering, Chongqing University of Technology, Chongqing 400054, China
| | - Yin Wang
- Chongqing Key Laboratory of Optical Fiber Sensor and Photoelectric Detection, Chongqing University of Technology, Chongqing 400054, China
| | - Linlin Wang
- School of Pharmacy and Bioengineering, Chongqing University of Technology, Chongqing 400054, China
| | - Yong Liu
- School of Opto-electronic Information, University of Electronic Science and Technology of China, Chengdu 610054, China
| |
Collapse
|