1
|
Zang Y, Cao B, Yi X, Zha F, Ge Y, Liu H, Yi Y. Enhancing water toxicity determination sensitivity by using TMAO as electron acceptor of inward extracellular electron transfer in electrochemically active bacteria. Bioelectrochemistry 2025; 164:108925. [PMID: 39893835 DOI: 10.1016/j.bioelechem.2025.108925] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2024] [Revised: 01/17/2025] [Accepted: 01/29/2025] [Indexed: 02/04/2025]
Abstract
Toxicity determination based on electrochemically active bacteria (EAB) shows great prospects for early warning of sudden water pollution. However, the main bottleneck for practical application is the low sensitivity. Extracellular electron transfer (EET) is a key parameter influencing sensitivity. Our previous research has demonstrated that EAB exhibit higher sensitivity when performing inward EET compared with outward EET. Inward EET relies on electron acceptors, but the effects of electron acceptors on sensitivity remain unclear. In this study, the sensitivity of toxicity determination with different electron acceptors was compared. Results indicated that the choice of electron acceptors significantly changed the sensitivity. When Trimethylamine N-oxide (TMAO) was chosen as the electron acceptor, EAB exhibited the highest sensitivity, with a lower response limit of 0.05 mg/L Cd2+. The main reason was that the utilization of TMAO for inward EET increases the membrane permeability of EAB cells, facilitates toxic pollutant penetration, and results in high mortality after toxicity exposure.
Collapse
Affiliation(s)
- Yuxuan Zang
- School of Medical, Shanxi Datong University, Datong 037009, China
| | - Bo Cao
- Institute of Environmental Biology and Life Support Technology, School of Biological Science and Medical Engineering, Beihang University, Beijing 100191, China; International Joint Research Center of Aerospace Biotechnology and Medical Engineering, Beihang University, Beijing 100191, China
| | - Xuemei Yi
- School of Life, Beijing Institute of Technology, Beijing 100081, China
| | - Fan Zha
- Infore Environment Technology Group, Foshan 528000, China
| | - Yanhong Ge
- Infore Environment Technology Group, Foshan 528000, China
| | - Hong Liu
- Institute of Environmental Biology and Life Support Technology, School of Biological Science and Medical Engineering, Beihang University, Beijing 100191, China; International Joint Research Center of Aerospace Biotechnology and Medical Engineering, Beihang University, Beijing 100191, China.
| | - Yue Yi
- School of Life, Beijing Institute of Technology, Beijing 100081, China.
| |
Collapse
|
2
|
Shi X, Liang Y, Wen G, Evlashin SA, Fedorov FS, Ma X, Feng Y, Zheng J, Wang Y, Shi J, Liu Y, Zhu W, Guo P, Kim BH. Review of cathodic electroactive bacteria: Species, properties, applications and electron transfer mechanisms. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 946:174332. [PMID: 38950630 DOI: 10.1016/j.scitotenv.2024.174332] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/06/2024] [Revised: 06/24/2024] [Accepted: 06/25/2024] [Indexed: 07/03/2024]
Abstract
Cathodic electroactive bacteria (C-EAB) which are capable of accepting electrons from solid electrodes provide fresh avenues for pollutant removal, biosensor design, and electrosynthesis. This review systematically summarized the burgeoning applications of the C-EAB over the past decade, including 1) removal of nitrate, aromatic derivatives, and metal ions; 2) biosensing based on biocathode; 3) electrosynthesis of CH4, H2, organic carbon, NH3, and protein. In addition, the mechanisms of electron transfer by the C-EAB are also classified and summarized. Extracellular electron transfer and interspecies electron transfer have been introduced, and the electron transport mechanism of typical C-EAB, such as Shewanella oneidensis MR-1, has been combed in detail. By bringing to light this cutting-edge area of the C-EAB, this review aims to stimulate more interest and research on not only exploring great potential applications of these electron-accepting bacteria, but also developing steady and scalable processes harnessing biocathodes.
Collapse
Affiliation(s)
- Xinxin Shi
- Shaanxi Key Laboratory of Environmental Engineering, Key Laboratory of Northwest Water Resource, Environment and Ecology, School of Environmental and Municipal Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China
| | - Yutong Liang
- Shaanxi Key Laboratory of Environmental Engineering, Key Laboratory of Northwest Water Resource, Environment and Ecology, School of Environmental and Municipal Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China
| | - Gang Wen
- Shaanxi Key Laboratory of Environmental Engineering, Key Laboratory of Northwest Water Resource, Environment and Ecology, School of Environmental and Municipal Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China.
| | - Stanislav A Evlashin
- Center for Materials Technologies, Skolkovo Institute of Science and Technology, the territory of the Skolkovo Innovation Center, Bolshoy Boulevard, 30, p.1, Moscow 121205, Russia
| | - Fedor S Fedorov
- Center for Photonic Science and Engineering, Skolkovo Institute of Science and Technology, the territory of the Skolkovo Innovation Center, Bolshoy Boulevard, 30, p.1, Moscow 121205, Russia
| | - Xinyue Ma
- Shaanxi Key Laboratory of Environmental Engineering, Key Laboratory of Northwest Water Resource, Environment and Ecology, School of Environmental and Municipal Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China
| | - Yujie Feng
- State Key Laboratory of Urban Water Resource and Environment, School of Environment, Harbin Institute of Technology, No 73 Huanghe Road, Nangang District, Harbin 150090, China
| | - Junjie Zheng
- Shaanxi Key Laboratory of Environmental Engineering, Key Laboratory of Northwest Water Resource, Environment and Ecology, School of Environmental and Municipal Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China
| | - Yixing Wang
- Shaanxi Key Laboratory of Environmental Engineering, Key Laboratory of Northwest Water Resource, Environment and Ecology, School of Environmental and Municipal Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China
| | - Julian Shi
- Xi'an Institute for Innovative Earth Environment Research, Xi'an 710061, China
| | - Yang Liu
- Shaanxi Land Engineering Construction Group Co., Ltd, Xi'an 710061, China
| | - Weihuang Zhu
- Shaanxi Key Laboratory of Environmental Engineering, Key Laboratory of Northwest Water Resource, Environment and Ecology, School of Environmental and Municipal Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China
| | - Pengfei Guo
- School of Civil Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China
| | - Byung Hong Kim
- State Key Laboratory of Urban Water Resource and Environment, School of Environment, Harbin Institute of Technology, No 73 Huanghe Road, Nangang District, Harbin 150090, China; Korea Institute of Science & Technology, Seongbug-ku, Seoul 02792, Republic of Korea
| |
Collapse
|
3
|
Xue J, Wang Y, Jing Y, Li X, Chen S, Xu Y, Song RB. Recent advances in microbial fuel cell-based self-powered biosensors: a comprehensive exploration of sensing strategies in both anode and cathode modes. Anal Bioanal Chem 2024; 416:4649-4662. [PMID: 38457006 DOI: 10.1007/s00216-024-05230-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2023] [Revised: 02/09/2024] [Accepted: 02/26/2024] [Indexed: 03/09/2024]
Abstract
With the rapid development of society, it is of paramount importance to expeditiously assess environmental pollution and provide early warning of toxicity risks. Microbial fuel cell-based self-powered biosensors (MFC-SPBs) have emerged as a pivotal technology, obviating the necessity for external power sources and aligning with the prevailing trends toward miniaturization and simplification in biosensor development. In this case, vigorous advancements in MFC-SPBs have been acquired in past years, irrespective of whether the target identification event transpires at the anode or cathode. The present article undertakes a comprehensive review of developed MFC-SPBs, categorizing them into substrate effect and microbial activity effect based on the nature of the target identification event. Furthermore, various enhancement strategies to improve the analytical performance like accuracy and sensitivity are also outlined, along with a discussion of future research trends and application prospects of MFC-SPBs for their better developments.
Collapse
Affiliation(s)
- Junjun Xue
- Henan Joint International Research Laboratory of Green Construction of Functional Molecules and Their Bioanalytical Applications, Zhengzhou Key Laboratory of Functional Nanomaterial and Medical Theranostic, Zhengzhou University, Zhengzhou, China
- School of Ecology and Environment, Zhengzhou University, Zhengzhou, China
| | - Yuxin Wang
- Henan Joint International Research Laboratory of Green Construction of Functional Molecules and Their Bioanalytical Applications, Zhengzhou Key Laboratory of Functional Nanomaterial and Medical Theranostic, Zhengzhou University, Zhengzhou, China
| | - Yuanyuan Jing
- Henan Joint International Research Laboratory of Intelligent Water Treatment System, Qingshuiyuan Technology Co., Ltd., Jiyuan, China
| | - Xiaoxuan Li
- School of Ecology and Environment, Zhengzhou University, Zhengzhou, China
| | - Suping Chen
- School of Ecology and Environment, Zhengzhou University, Zhengzhou, China
| | - Ying Xu
- Henan Joint International Research Laboratory of Green Construction of Functional Molecules and Their Bioanalytical Applications, Zhengzhou Key Laboratory of Functional Nanomaterial and Medical Theranostic, Zhengzhou University, Zhengzhou, China.
- School of Ecology and Environment, Zhengzhou University, Zhengzhou, China.
| | - Rong-Bin Song
- Henan Joint International Research Laboratory of Green Construction of Functional Molecules and Their Bioanalytical Applications, Zhengzhou Key Laboratory of Functional Nanomaterial and Medical Theranostic, Zhengzhou University, Zhengzhou, China.
- School of Ecology and Environment, Zhengzhou University, Zhengzhou, China.
| |
Collapse
|
4
|
Wang LN, Wang XJ, Jin KX, Ni ZR, Cai WP, Lin GC, Wang X, Chen GL, Yang Y, Huang YQ, Qu XB, Sun HJ, Chen Z, Cao SH. Compact In Situ Electrochemical NMR with Wireless and Anti-interference Strategy in Multiscenario Applications. Anal Chem 2024; 96:10911-10919. [PMID: 38916969 DOI: 10.1021/acs.analchem.4c00807] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/27/2024]
Abstract
The integration of electrochemistry with nuclear magnetic resonance (NMR) spectroscopy recently offers a powerful approach to understanding oxidative metabolism, detecting reactive intermediates, and predicting biological activities. This combination is particularly effective as electrochemical methods provide excellent mimics of metabolic processes, while NMR spectroscopy offers precise chemical analysis. NMR is already widely utilized in the quality control of pharmaceuticals, foods, and additives and in metabolomic studies. However, the introduction of additional and external connections into the magnet has posed challenges, leading to signal deterioration and limitations in routine measurements. Herein, we report an anti-interference compact in situ electrochemical NMR system (AICISENS). Through a wireless strategy, the compact design allows for the independent and stable operation of electrochemical NMR components with effective interference isolation. Thus, it opens an avenue toward easy integration into in situ platforms, applicable not only to laboratory settings but also to fieldwork. The operability, reliability, and versatility were validated with a series of biomimetic assessments, including measurements of microbial electrochemical systems, functional foods, and simulated drug metabolisms. The robust performance of AICISENS demonstrates its high potential as a powerful analytical tool across diverse applications.
Collapse
Affiliation(s)
- Li-Na Wang
- State Key Laboratory of Physical Chemistry of Solid Surfaces, the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Department of Electronic Science, Xiamen University, Xiamen 361005, China
| | - Xi-Ji Wang
- State Key Laboratory of Physical Chemistry of Solid Surfaces, the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Department of Electronic Science, Xiamen University, Xiamen 361005, China
| | - Ke-Xin Jin
- State Key Laboratory of Physical Chemistry of Solid Surfaces, the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Department of Electronic Science, Xiamen University, Xiamen 361005, China
| | - Zu-Rong Ni
- State Key Laboratory of Physical Chemistry of Solid Surfaces, the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Department of Electronic Science, Xiamen University, Xiamen 361005, China
| | - Wei-Peng Cai
- Xiamen Municipal Center for Disease Control and Prevention, Xiamen 361021, China
| | - Guo-Chun Lin
- State Key Laboratory of Physical Chemistry of Solid Surfaces, the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Department of Electronic Science, Xiamen University, Xiamen 361005, China
| | - Xin Wang
- State Key Laboratory of Physical Chemistry of Solid Surfaces, the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Department of Electronic Science, Xiamen University, Xiamen 361005, China
| | - Guo-Long Chen
- State Key Laboratory of Physical Chemistry of Solid Surfaces, the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Department of Electronic Science, Xiamen University, Xiamen 361005, China
| | - Yu Yang
- State Key Laboratory of Physical Chemistry of Solid Surfaces, the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Department of Electronic Science, Xiamen University, Xiamen 361005, China
| | - Yu-Qing Huang
- State Key Laboratory of Physical Chemistry of Solid Surfaces, the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Department of Electronic Science, Xiamen University, Xiamen 361005, China
| | - Xiao-Bo Qu
- State Key Laboratory of Physical Chemistry of Solid Surfaces, the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Department of Electronic Science, Xiamen University, Xiamen 361005, China
| | - Hui-Jun Sun
- State Key Laboratory of Physical Chemistry of Solid Surfaces, the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Department of Electronic Science, Xiamen University, Xiamen 361005, China
| | - Zhong Chen
- State Key Laboratory of Physical Chemistry of Solid Surfaces, the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Department of Electronic Science, Xiamen University, Xiamen 361005, China
| | - Shuo-Hui Cao
- State Key Laboratory of Physical Chemistry of Solid Surfaces, the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Department of Electronic Science, Xiamen University, Xiamen 361005, China
- Shenzhen Research Institute of Xiamen University, Shenzhen 518000, China
| |
Collapse
|
5
|
Liu X, Wang D, Qi X, Gu Y, Huang X, Liang P. Propionate outperforms conventional acetate as electron donors for highly-sensitive electrochemical active biofilm sensors in water biotoxicity early-warning. ENVIRONMENTAL RESEARCH 2024; 252:119127. [PMID: 38750998 DOI: 10.1016/j.envres.2024.119127] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/04/2024] [Revised: 05/07/2024] [Accepted: 05/09/2024] [Indexed: 05/18/2024]
Abstract
With the ability to generate in situ real-time electric signals, electrochemically active biofilm (EAB) sensors have attracted wide attention as a promising water biotoxicity early-warning device. Organic matters serving as the electron donors potentially affect the electric signal's output and the sensitivity of the EAB sensor. To explore the influence of organic matters on EAB sensor's performance, this study tested six different organic matters during the sensor's inoculation. Besides the acetate, a conventional and widely used organic matter, propionate and lactate were also found capable of starting up the sensor. Moreover, the propionate-fed (PF) sensor delivered the highest sensitivity, which are respectively 1.4 times and 2.8 times of acetate-fed (AF) sensor and lactate-fed (LF) sensor. Further analysis revealed that EAB of PF sensor had more vulnerable intracellular metabolism than the others, which manifested as the most severe energy metabolic suppression and reactive oxygen species attack. Regarding the microbial function, a two-component system that was deemed as an environment awareness system was found in the EAB of PF, which also contributed to its high sensitivity. Finally, PF sensor was tested in real water environment to deliver early-warning signals.
Collapse
Affiliation(s)
- Xinning Liu
- State Key Joint Laboratory of Environment Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing, 100084, China
| | - Donglin Wang
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China
| | - Xiang Qi
- State Key Joint Laboratory of Environment Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing, 100084, China.
| | - Yuyi Gu
- State Key Joint Laboratory of Environment Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing, 100084, China
| | - Xia Huang
- State Key Joint Laboratory of Environment Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing, 100084, China
| | - Peng Liang
- State Key Joint Laboratory of Environment Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing, 100084, China.
| |
Collapse
|
6
|
Maan KS, Gajbhiye P, Sharma A, Al-Gheethi AA. Efficient anode material derived from nutshells for bio-energy production in microbial fuel cell. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2024; 364:121422. [PMID: 38878572 DOI: 10.1016/j.jenvman.2024.121422] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Revised: 05/02/2024] [Accepted: 06/06/2024] [Indexed: 06/24/2024]
Abstract
Biochar is a carbonaceous solid that is prepared through thermo-chemical decomposition of biomass under an inert atmosphere. The present study compares the performance of biochar prepared from Peanut shell, coconut shell and walnut shell in dual chamber microbial fuel cell. The physicochemical and electrochemical analysis of biochar reveals that prepared biochar is macroporous, amorphous, biocompatible, and electrochemically conductive. Polarization studies show that Peanut shell biochar (PSB) exhibited a maximum power density of 165 mW/m2 followed by Coconut shell biochar (CSB) Activated Charcoal (AC) and Walnut shell biochar (WSB). Enhanced power density of PSB was attributed to its surface area and suitable pore size distribution which proved conducive for biofilm formation. Furthermore, the high electrical capacitance of PSB improved the electron transfer between microbes and anode.
Collapse
Affiliation(s)
- Karan Singh Maan
- Department of Chemical Engineering, School of Chemical Engineering and Physical Sciences, Lovely Professional University, Jalandhar, 144411, India; Department of Chemistry, School of Chemical Engineering and Physical Sciences, Lovely Professional University, Jalandhar, 144411, India
| | - Pratima Gajbhiye
- Department of Chemical Engineering, School of Chemical Engineering and Physical Sciences, Lovely Professional University, Jalandhar, 144411, India.
| | - Ajit Sharma
- Department of Chemistry, School of Chemical Engineering and Physical Sciences, Lovely Professional University, Jalandhar, 144411, India.
| | - Adel-Ali Al-Gheethi
- Global Centre for Environmental Remediation (GCER), University of Newcastle and CRC for Contamination Assessment and Remediation of the Environment (CRC CARE), Newcastle, Australia
| |
Collapse
|
7
|
Perchikov R, Cheliukanov M, Plekhanova Y, Tarasov S, Kharkova A, Butusov D, Arlyapov V, Nakamura H, Reshetilov A. Microbial Biofilms: Features of Formation and Potential for Use in Bioelectrochemical Devices. BIOSENSORS 2024; 14:302. [PMID: 38920606 PMCID: PMC11201457 DOI: 10.3390/bios14060302] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/15/2024] [Revised: 06/03/2024] [Accepted: 06/05/2024] [Indexed: 06/27/2024]
Abstract
Microbial biofilms present one of the most widespread forms of life on Earth. The formation of microbial communities on various surfaces presents a major challenge in a variety of fields, including medicine, the food industry, shipping, etc. At the same time, this process can also be used for the benefit of humans-in bioremediation, wastewater treatment, and various biotechnological processes. The main direction of using electroactive microbial biofilms is their incorporation into the composition of biosensor and biofuel cells This review examines the fundamental knowledge acquired about the structure and formation of biofilms, the properties they have when used in bioelectrochemical devices, and the characteristics of the formation of these structures on different surfaces. Special attention is given to the potential of applying the latest advances in genetic engineering in order to improve the performance of microbial biofilm-based devices and to regulate the processes that take place within them. Finally, we highlight possible ways of dealing with the drawbacks of using biofilms in the creation of highly efficient biosensors and biofuel cells.
Collapse
Affiliation(s)
- Roman Perchikov
- Federal State Budgetary Educational Institution of Higher Education, Tula State University, Tula 300012, Russia; (R.P.); (M.C.); (A.K.); (V.A.)
| | - Maxim Cheliukanov
- Federal State Budgetary Educational Institution of Higher Education, Tula State University, Tula 300012, Russia; (R.P.); (M.C.); (A.K.); (V.A.)
| | - Yulia Plekhanova
- Federal Research Center (Pushchino Scientific Center for Biological Research of the Russian Academy of Sciences), G.K. Skryabin Institute of Biochemistry and Physiology of Microorganisms, Russian Academy of Sciences, Pushchino 142290, Russia; (Y.P.); (S.T.)
| | - Sergei Tarasov
- Federal Research Center (Pushchino Scientific Center for Biological Research of the Russian Academy of Sciences), G.K. Skryabin Institute of Biochemistry and Physiology of Microorganisms, Russian Academy of Sciences, Pushchino 142290, Russia; (Y.P.); (S.T.)
| | - Anna Kharkova
- Federal State Budgetary Educational Institution of Higher Education, Tula State University, Tula 300012, Russia; (R.P.); (M.C.); (A.K.); (V.A.)
| | - Denis Butusov
- Computer-Aided Design Department, Saint Petersburg Electrotechnical University “LETI”, Saint Petersburg 197022, Russia;
| | - Vyacheslav Arlyapov
- Federal State Budgetary Educational Institution of Higher Education, Tula State University, Tula 300012, Russia; (R.P.); (M.C.); (A.K.); (V.A.)
| | - Hideaki Nakamura
- Department of Liberal Arts, Tokyo University of Technology, 1404-1 Katakura, Hachioji 192-0982, Tokyo, Japan;
| | - Anatoly Reshetilov
- Federal Research Center (Pushchino Scientific Center for Biological Research of the Russian Academy of Sciences), G.K. Skryabin Institute of Biochemistry and Physiology of Microorganisms, Russian Academy of Sciences, Pushchino 142290, Russia; (Y.P.); (S.T.)
| |
Collapse
|
8
|
Carducci NGG, Dey S, Hickey DP. Recent Developments and Applications of Microbial Electrochemical Biosensors. ADVANCES IN BIOCHEMICAL ENGINEERING/BIOTECHNOLOGY 2024; 187:149-183. [PMID: 38273205 DOI: 10.1007/10_2023_236] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/27/2024]
Abstract
This chapter provides a comprehensive overview of microbial electrochemical biosensors, which are a unique class of biosensors that utilize the metabolic activity of microorganisms to convert chemical signals into electrical signals. The principles and mechanisms of these biosensors are discussed, including the different types of microorganisms that can be used. The various applications of microbial electrochemical biosensors in fields such as environmental monitoring, medical diagnostics, and food safety are also explored. The chapter concludes with a discussion of future research directions and potential advancements in the field of microbial electrochemical biosensors.
Collapse
Affiliation(s)
- Nunzio Giorgio G Carducci
- Department of Chemical Engineering and Materials Science, Michigan State University, East Lansing, MI, USA
| | - Sunanda Dey
- Department of Chemical Engineering and Materials Science, Michigan State University, East Lansing, MI, USA
| | - David P Hickey
- Department of Chemical Engineering and Materials Science, Michigan State University, East Lansing, MI, USA.
| |
Collapse
|
9
|
Yeo RYZ, Chin BH, Hil Me MF, Chia JF, Pham HT, Othman AR, Mohammad AW, Ang WL, Lim SS. Rapid Surface Modification of Stainless Steel 304L Electrodes for Microbial Electrochemical Sensor Application. ACS Biomater Sci Eng 2023; 9:6034-6044. [PMID: 37846081 DOI: 10.1021/acsbiomaterials.3c00453] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2023]
Abstract
Electrogenic microorganisms serve as important biocatalysts for microbial electrochemical sensors (MESes). The electrical signal produced is based on the rate of electron transfer between the microbes and electrodes, which represents the biotoxicity of water. However, existing MESes require complex and sophisticated fabrication methods. Here, several low-cost and rapid surface modification strategies (carbon powder-coated, flame-oxidized, and acid-bleached) have been demonstrated and studied for biosensing purposes. Surface-modified MESe bioanodes were successfully applied to detect multiple model pollutants including sodium acetate, ethanol, thinner, and palm oil mill effluent under three different testing sequences, namely, pollutant incremental, pollutant dumping, and water dilution tests. The carbon powder-coated bioanode showed the most responsive signal profile for all the three tests, which is in line with the average roughness values (Ra) when tested with atomic force microscopy. The carbon powder-coated electrode possessed a Ra value of 0.844, while flame-oxidized, acid-bleached, and control samples recorded 0.323, 0.336, and 0.264, respectively. The higher roughness was caused by the carbon coating and provided adhesive sites for microbial attachment and growth. The accuracy of MESe was also verified by correlating with chemical oxygen demand (COD) results. Similar to the sensitivity test, the carbon powder-coated bioanode obtained the highest R2 value of 0.9754 when correlated with COD results, indicating a high potential of replacing conventional water quality analysis methods. The reported work is of great significance to showcase facile surface modification techniques for MESes, which are cost-effective and sustainable while retaining the biocompatibility toward the microbial community with carbon-based coatings.
Collapse
Affiliation(s)
- Ryan Yow Zhong Yeo
- Fuel Cell Institute, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, Malaysia
- Department of Chemical and Process Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, Malaysia
| | - Bin Hou Chin
- Department of Applied Physics, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, Malaysia
| | | | - Jan Feng Chia
- Department of Chemical and Process Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, Malaysia
| | - Hai The Pham
- Department of Microbiology and Center for Life Science Research (CELIFE), Faculty of Biology, VNU University of Science, Vietnam National University, Nguyen Trai 334, Thanh Xuan, Hanoi, Vietnam
| | - Ahmad Razi Othman
- Department of Chemical and Process Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, Malaysia
| | - Abdul Wahab Mohammad
- Chemical and Water Desalination Program, College of Engineering, University of Sharjah, Sharjah 27272, United Arab Emirates
| | - Wei Lun Ang
- Department of Chemical and Process Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, Malaysia
| | - Swee Su Lim
- Fuel Cell Institute, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, Malaysia
| |
Collapse
|
10
|
Adekunle A, Bambace S, Tanguay-Rioux F, Tartakovsky B. Microbial Fuel Cell Biosensor with Capillary Carbon Source Delivery for Real-Time Toxicity Detection. SENSORS (BASEL, SWITZERLAND) 2023; 23:7065. [PMID: 37631603 PMCID: PMC10458999 DOI: 10.3390/s23167065] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/29/2023] [Revised: 07/18/2023] [Accepted: 07/31/2023] [Indexed: 08/27/2023]
Abstract
A microbial fuel cell (MFC) biosensor with an anode as a sensing element is often unreliable at low or significantly fluctuating organic matter concentrations. To remove this limitation, this work demonstrates capillary action-aided carbon source delivery to an anode-sensing MFC biosensor for use in carbon-depleted environments, e.g., potable water. First, different carbon source delivery configurations using several thread types, silk, nylon, cotton, and polyester, are evaluated. Silk thread was determined to be the most suitable material for passive delivery of a 40 g L-1 acetate solution. This carbon source delivery system was then incorporated into the design of an MFC biosensor for real-time detection of toxicity spikes in tap water, providing an organic matter concentration of 56 ± 15 mg L-1. The biosensor was subsequently able to detect spikes of toxicants such as chlorine, formaldehyde, mercury, and cyanobacterial microcystins. The 16S sequencing results demonstrated the proliferation of Desulfatirhabdium (10.7% of the total population), Pelobacter (10.3%), and Geobacter (10.2%) genera. Overall, this work shows that the proposed approach can be used to achieve real-time toxicant detection by MFC biosensors in carbon-depleted environments.
Collapse
Affiliation(s)
- Ademola Adekunle
- National Research Council of Canada, 6100 Royalmount Ave, Montreal, QC H4P 2R2, Canada
| | - Stefano Bambace
- Faculty of Engineering, McGill University, 3480 Rue University #350, Montreal, QC H3A 0E9, Canada
| | - Fabrice Tanguay-Rioux
- National Research Council of Canada, 6100 Royalmount Ave, Montreal, QC H4P 2R2, Canada
| | - Boris Tartakovsky
- National Research Council of Canada, 6100 Royalmount Ave, Montreal, QC H4P 2R2, Canada
| |
Collapse
|
11
|
Yao H, Xiao J, Tang X. Microbial Fuel Cell-Based Organic Matter Sensors: Principles, Structures and Applications. Bioengineering (Basel) 2023; 10:886. [PMID: 37627771 PMCID: PMC10451650 DOI: 10.3390/bioengineering10080886] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Revised: 07/24/2023] [Accepted: 07/25/2023] [Indexed: 08/27/2023] Open
Abstract
Wastewater contains a significant quantity of organic matter, continuously causing environmental pollution. Timely and accurate detection of organic content in water can facilitate improved wastewater treatment and better protect the environment. Microbial fuel cells (MFCs) are increasingly recognized as valuable biological monitoring systems, due to their ability to swiftly detect organic indicators such as biological oxygen demand (BOD) and chemical oxygen demand (COD) in water quality. Different types of MFC sensors are used for BOD and COD detection, each with unique features and benefits. This review focuses on different types of MFC sensors used for BOD and COD detection, discussing their benefits and structural optimization, as well as the influencing factors of MFC-based biomonitoring systems. Additionally, the challenges and prospects associated with the development of reliable MFC sensing systems are discussed.
Collapse
Affiliation(s)
| | | | - Xinhua Tang
- School of Civil Engineering and Architecture, Wuhan University of Technology, Wuhan 430062, China
| |
Collapse
|
12
|
Sharma A, Chhabra M. The versatility of microbial fuel cells as tools for organic matter monitoring. BIORESOURCE TECHNOLOGY 2023; 377:128949. [PMID: 36963695 DOI: 10.1016/j.biortech.2023.128949] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Revised: 03/17/2023] [Accepted: 03/20/2023] [Indexed: 06/18/2023]
Abstract
Water monitoring and remediation require robust, low-cost, and reliable test systems that can couple with prompt treatment interventions. Organic matter (BOD, COD), toxicants, heavy metals, and other pollutants in water need to be regularly inspected. Microbial fuel cells (MFCs) have already gained popularity as BOD biomonitoring systems as these don't need an external transducer or power source. Moreover, these systems are cost-effective, compact, biodegradable, reusable, portable, and applicable for on-site measurements. MFCs truly stands out as online BOD measurement devices as they provide wide detection range (0-25 g/L), low response time (2-4 min) and longer stability in continuous operations (2-5 years) in a cost-effective approach. This review examines the benefits, kinds, performance metrics, and signal optimization of the current state-of-the-art of the BOD measurement, with detailed focus on MFC-based BOD biomonitoring systems. This review covers the important technological breakthroughs in practical applications with associated bottlenecks to develop reliable sensing systems.
Collapse
Affiliation(s)
- Arti Sharma
- Environmental Biotechnology Laboratory, Department of Bioscience and Bioengineering, Indian Institute of Technology Jodhpur (IIT J), Jodhpur 342030, Rajasthan, India
| | - Meenu Chhabra
- Environmental Biotechnology Laboratory, Department of Bioscience and Bioengineering, Indian Institute of Technology Jodhpur (IIT J), Jodhpur 342030, Rajasthan, India.
| |
Collapse
|
13
|
Han Y, Li H, Liao C, Zhu X, Wang Z, Yan J, Wang X. Rapid warning of emerging contaminants in reuse water using biocathode sensors. JOURNAL OF HAZARDOUS MATERIALS 2023; 457:131735. [PMID: 37269559 DOI: 10.1016/j.jhazmat.2023.131735] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Revised: 05/12/2023] [Accepted: 05/28/2023] [Indexed: 06/05/2023]
Abstract
The proliferation of emerging contaminants (ECs) in the environment poses a major threat to the safety of reuse water. However, many ECs exist for which no corresponding control standards have been established. Here, we used polarity reversal to construct a biocathode sensor capable of early warning of ECs biotoxicity in aerobic reuse water with low organic concentrations. The baseline current and sensitivity of the biosensor in response to formaldehyde were enhanced by 25% and 23% using microbial fuel cell effluent as the inoculum. The microbial community explained that the inoculum primarily influenced the performance of the biosensor by modulating species abundance, function and interactions. More importantly, the successfully commissioned biocathode sensor demonstrated rapid warning capability (Response time less than 1.3 h) for ECs such as fluoride, disinfection by-products and antibiotics in an actual landscape reuse system. Further, the sensor could quantify the concentration of a single known contaminant. Our study demonstrated a method for rapid early warning of ECs in an oxygen-rich, low-organics environment, promoting innovative development of monitoring technologies for water ecology and environmental safety.
Collapse
Affiliation(s)
- Yilian Han
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan, Tianjin 300350, China
| | - Haotong Li
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan, Tianjin 300350, China; Department of Environmental Science and Engineering, University of Science and Technology of China, Hefei 230026, China
| | - Chengmei Liao
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan, Tianjin 300350, China.
| | - Xuemei Zhu
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan, Tianjin 300350, China
| | - Ziyuan Wang
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan, Tianjin 300350, China
| | - Jiaguo Yan
- Division of Oilfield Chemicals, China Oilfield Services Limited, No. 1581 Haichuan Road, Binhai New District, Tianjin 300459, China
| | - Xin Wang
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan, Tianjin 300350, China.
| |
Collapse
|
14
|
Han Y, Liao C, Meng X, Zhao Q, Yan X, Tian L, Liu Y, Li N, Wang X. Switchover of electrotrophic and heterotrophic respirations enables the biomonitoring of low concentration of BOD in oxygen-rich environment. WATER RESEARCH 2023; 235:119897. [PMID: 36963309 DOI: 10.1016/j.watres.2023.119897] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/29/2022] [Revised: 03/16/2023] [Accepted: 03/18/2023] [Indexed: 06/18/2023]
Abstract
Biochemical oxygen demand (BOD) is a key indicator of water quality. However, there is still no technique to directly measure BOD at low concentrations in oxygen-rich environments. Here, we propose a new scheme using facultative electrotrophs as the sensing element, and confirmed aerobic Acinetobacter venetianus RAG-1 immobilized on electrode was able to measure BOD via the switchover between electrotrophic and heterotrophic respirations. The hybrid binder of Nafion and polytetrafluoroethylene (PTFE) maximized the baseline current (127 ± 2 A/m2) and sensitivity (2.5 ± 0.1 (mA/m2)/(mg/L)). The current decrease and the BOD5 concentration fitted well with a linear model in the case of known contaminants, verified with both lab samples of acetate and glucose (R2>0.96) and in standard curves of real environmental samples collected from the lake and the effluent of wastewater treatment plant (R2>0.98). Importantly, the biosensor tested actual contaminated water samples with an error of 0.4∼10% compared to BOD5 in the case of unknown contaminants. Transcriptomics revealed that reverse oxidative TCA may involve in the electrotrophic respiration of RAG-1 since citrate synthase (gltA) was highly expressed, which was partly downregulated when heterotrophic metabolism was triggered by BOD. This can be returned to electrotroph when BOD was depleted. Our results showed a new way to rapidly measure BOD in oxygen-rich environment, demonstrating the possibility to employ bacteria with two competitive respiration pathways for pollution detection.
Collapse
Affiliation(s)
- Yilian Han
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin 300350, China
| | - Chengmei Liao
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin 300350, China.
| | - Xinyi Meng
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin 300350, China
| | - Qian Zhao
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin 300350, China
| | - Xuejun Yan
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin 300350, China
| | - Lili Tian
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin 300350, China
| | - Ying Liu
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin 300350, China
| | - Nan Li
- School of Environmental Science and Engineering, Tianjin University, No. 35 Yaguan Road, Jinnan District, Tianjin 300350, China
| | - Xin Wang
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin 300350, China.
| |
Collapse
|
15
|
Abstract
The sustainable development of human society in today's high-tech world depends on some form of eco-friendly energy source because existing technologies cannot keep up with the rapid population expansion and the vast amounts of wastewater that result from human activity. A green technology called a microbial fuel cell (MFC) focuses on using biodegradable trash as a substrate to harness the power of bacteria to produce bioenergy. Production of bioenergy and wastewater treatment are the two main uses of MFC. MFCs have also been used in biosensors, water desalination, polluted soil remediation, and the manufacture of chemicals like methane and formate. MFC-based biosensors have gained a lot of attention in the last few decades due to their straightforward operating principle and long-term viability, with a wide range of applications including bioenergy production, treatment of industrial and domestic wastewater, biological oxygen demand, toxicity detection, microbial activity detection, and air quality monitoring, etc. This review focuses on several MFC types and their functions, including the detection of microbial activity.
Collapse
|
16
|
Liao C, Tian L, Wang Z, Zhu X, Han Y, Li T, Wang X. Toxicity warning and online monitoring of disinfection by-products in water by electroautotrophic biocathode sensors. Biosens Bioelectron 2023; 219:114799. [PMID: 36252314 PMCID: PMC9550284 DOI: 10.1016/j.bios.2022.114799] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2022] [Revised: 09/19/2022] [Accepted: 10/08/2022] [Indexed: 11/19/2022]
Abstract
As a result of the 2019 coronavirus pandemic, disinfection byproducts generated by the extensive use of chlorine disinfectants have infiltrated the aquatic environment, severely threatening ecological safety and human health. Therefore, the accurate monitoring of the biotoxicity of aqueous environments has become an important issue. Biocathode sensors are excellent choices for toxicity monitoring because of their special electroautotrophic respiration functions. Herein, a novel electroautotrophic biosensor with rapid, sensitive, and stable response and quantifiable output was developed. Its toxicity response was tested with typical disinfection byproducts dichloromethane, trichloromethane, and combinations of both, and corresponding characterization models were developed. Repeated toxicity tests demonstrated that the sensor was reusable rather being than a disposable consumable, which is a prerequisite for its long-term and stable operation. Microbial viability confirmed a decrease in sensor sensitivity due to microbial stress feedback to the toxicants, which is expected to be calibrated in the future by the standardization of the biofilms. Community structure analysis indicated that Moheibacter and Nitrospiraceae played an important role in the toxic response to chlorine disinfection byproducts. Our research provides technical support for protecting the environment and safeguarding water safety for human consumption and contributes new concepts for the development of novel electrochemical sensors.
Collapse
Affiliation(s)
- Chengmei Liao
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin, 300350, China
| | - Lili Tian
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin, 300350, China.
| | - Ziyuan Wang
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin, 300350, China
| | - Xuemei Zhu
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin, 300350, China
| | - Yilian Han
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin, 300350, China
| | - Tian Li
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin, 300350, China
| | - Xin Wang
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin, 300350, China.
| |
Collapse
|
17
|
Yang C, Xiao N, Yang S, Huang JJ. Micro response mechanism of mini MFC sensor performance to temperature and its applicability to actual wastewater. Chem Eng Sci 2022. [DOI: 10.1016/j.ces.2022.118124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
18
|
Chu N, Jiang Y, Zhang L, Zeng RJ, Li D. Biocathode prepared at low anodic potentials achieved a higher response for water biotoxicity monitoring after polarity reversal. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 847:157553. [PMID: 35878860 DOI: 10.1016/j.scitotenv.2022.157553] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Revised: 07/17/2022] [Accepted: 07/18/2022] [Indexed: 06/15/2023]
Abstract
Microbial electrochemical sensors equipped with biocathode sensing elements have attracted a growing interest, but their startup and recovery properties remain unclear. In this study, the approach of polarity reversal was applied for the biocathode sensing element fabrication and biosensor recovery. The stimulating/suppressing effect of formaldehyde was determined by the anode potential before polarity reversal as well as the increased trials of toxic exposure. Increasing anode potential from -0.3 V to +0.3 V before polarity reversal, the baseline electric signal was changed from -0.028 ± 0.001 mA to -0.005 ± 0.003 mA, while the maximum normalized electrical signal (NES) was increased from 1.1 ± 0.1 to 4.1 ± 1.9, and thus a general downtrend was observed for Response as a newly induced indicator. Polarity reversal failed to recover the electroactivity of these poisoned bioelectrodes. This study demonstrated that electrode potential was critical when using the approach of polarity reversal to construct the biocathode sensing element, and revealed an urgent need for strategies toward high recoverability of such biosensors.
Collapse
Affiliation(s)
- Na Chu
- CAS Key Laboratory of Environmental and Applied Microbiology, Environmental Microbiology Key Laboratory of Sichuan Province, Chengdu Institute of Biology, Chinese Academy of Sciences, Chengdu 610041, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | - Yong Jiang
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou 350002, China
| | - Lixia Zhang
- CAS Key Laboratory of Environmental and Applied Microbiology, Environmental Microbiology Key Laboratory of Sichuan Province, Chengdu Institute of Biology, Chinese Academy of Sciences, Chengdu 610041, China
| | - Raymond Jianxiong Zeng
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou 350002, China
| | - Daping Li
- CAS Key Laboratory of Environmental and Applied Microbiology, Environmental Microbiology Key Laboratory of Sichuan Province, Chengdu Institute of Biology, Chinese Academy of Sciences, Chengdu 610041, China.
| |
Collapse
|
19
|
A novel, environmentally friendly dual-signal water toxicity biosensor developed through the continuous release of Fe3+. Biosens Bioelectron 2022; 220:114864. [DOI: 10.1016/j.bios.2022.114864] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2022] [Revised: 10/12/2022] [Accepted: 10/25/2022] [Indexed: 11/06/2022]
|
20
|
Wu H, Cui M, Yang X, Liu Y, Wang J, Zhang L, Zhan G, Zhao Y. Visual signal sensor coupling to nitrification for sustainable monitoring of trichloroacetaldehyde and the response mechanisms. Bioelectrochemistry 2022; 146:108142. [DOI: 10.1016/j.bioelechem.2022.108142] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2021] [Revised: 04/16/2022] [Accepted: 04/20/2022] [Indexed: 11/02/2022]
|
21
|
Boas JV, Oliveira VB, Simões M, Pinto AMFR. Review on microbial fuel cells applications, developments and costs. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2022; 307:114525. [PMID: 35091241 DOI: 10.1016/j.jenvman.2022.114525] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/22/2021] [Revised: 01/11/2022] [Accepted: 01/13/2022] [Indexed: 06/14/2023]
Abstract
The microbial fuel cell (MFC) technology has attracted significant attention in the last years due to its potential to recover energy in a wastewater treatment. The idea of using an MFC in industry is very attractive as the organic wastes can be converted into energy, reducing the waste disposal costs and the energy needs while increasing the company profit. However, taking aside these promising prospects, the attempts to apply MFCs in large-scale have not been succeeded so far since their lower performance and high costs remains challenging. This review intends to present the main applications of the MFC systems and its developments, particularly the advances on configuration and operating conditions. The diagnostic techniques used to evaluate the MFC performance as well as the different modeling approaches are described. Towards the introduction of the MFC in the market, a cost analysis is also included. The development of low-cost materials and more efficient systems, with high higher power outputs and durability, are crucial towards the application of MFCs in industrial/large scale. This work is a helpful tool for discovering new operation and design regimes.
Collapse
Affiliation(s)
- Joana Vilas Boas
- CEFT, Department of Chemical Engineering, Faculty of Engineering of the University of Porto, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal
| | - Vânia B Oliveira
- CEFT, Department of Chemical Engineering, Faculty of Engineering of the University of Porto, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal.
| | - Manuel Simões
- LEPABE, Department of Chemical Engineering, Faculty of Engineering of the University of Porto, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal
| | - Alexandra M F R Pinto
- CEFT, Department of Chemical Engineering, Faculty of Engineering of the University of Porto, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal.
| |
Collapse
|
22
|
A high-sensitive and durable electrochemical sensor based on Geobacter-dominated biofilms for heavy metal toxicity detection. Biosens Bioelectron 2022; 206:114146. [PMID: 35272214 DOI: 10.1016/j.bios.2022.114146] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2022] [Revised: 02/25/2022] [Accepted: 02/28/2022] [Indexed: 11/20/2022]
Abstract
A highly sensitive electrochemical sensor for detecting low concentrations of heavy metals (Cd2+, Ni2+, Pb2+ and Cu2+) based on Geobacter-dominated biofilms was developed. The biosensor showed a high sensitivity for the determination of Cd2+ (109.7 μAμM-1cm-2) and the determination of Pb2+ (161.7 μAμM-1cm-2). The performance of three fitting models for biosensor response to heavy metal toxicity was investigated based on the relationship between total coulomb yield and heavy metal concentration. The full-area model (Equation a) provided the best fit, and the response times tended to be the fastest based on the peak current model (Equation c). Recovery methods were proposed to ensure the electrical activity of the biofilm for long-term monitoring. 16S rRNA gene sequence analysis showed that the most dominant genus in the anodic biofilm was Geobacter (44.1%-45.8%), indicating a stable community structure after continuous toxicity shock for 22 days. The confocal laser scanning microscope (CLSM) further proved the restorable and reusability of the biosensor. Thanks to the thin and electrically active Geobacter-dominated biofilms, it could be a good alternative biosensor for groundwater analysis etc. The results of this study contribute to the development of a highly sensitive and accurate biosensor with long-term usage towards on-site monitoring of heavy metals at low concentrations, improving the test performance of the biosensor for practical application.
Collapse
|
23
|
Kumar T, Naik S, Jujjavarappu SE. A critical review on early-warning electrochemical system on microbial fuel cell-based biosensor for on-site water quality monitoring. CHEMOSPHERE 2022; 291:133098. [PMID: 34848233 DOI: 10.1016/j.chemosphere.2021.133098] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Revised: 11/21/2021] [Accepted: 11/25/2021] [Indexed: 05/15/2023]
Abstract
The microbial fuel cell (MFC) sensor is a very promising self-powered self-sustainable system for early warning water quality detection. These sensors are cost-effective, biodegradable, compact in design, and portable in nature are favorable for real-time in situ water quality monitoring. This review represents the mechanism action behind the toxicity detection, optimization strategies, process parameters, role of biofilm, the role of external resistance, hydrodynamic study, and mathematical modeling for improving the performance of the sensor. Additionally, the techno-economic prospect of this MFC-based sensor and its challenges, limitations are addressed to make it economically more favorable for commercial use. The future direction is also explored based on the sensor's disadvantages and limitations. Comprehensively, this review covered all the possible directions of MFC sensor fabrication, their application, recent advancement, prospects challenges, and their possible solutions.
Collapse
Affiliation(s)
- Tukendra Kumar
- Department of Biotechnology, National Institute of Technology, Raipur, Chhattisgarh, 492001, India
| | - Sweta Naik
- Department of Biotechnology, National Institute of Technology, Raipur, Chhattisgarh, 492001, India
| | | |
Collapse
|
24
|
Saravanan A, Kumar PS, Srinivasan S, Jeevanantham S, Kamalesh R, Karishma S. Sustainable strategy on microbial fuel cell to treat the wastewater for the production of green energy. CHEMOSPHERE 2022; 290:133295. [PMID: 34914952 DOI: 10.1016/j.chemosphere.2021.133295] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Revised: 12/07/2021] [Accepted: 12/11/2021] [Indexed: 06/14/2023]
Abstract
Microbial fuel cell (MFC) is one of the promising alternative energy systems where the catalytic conversion of chemical energy into electrical energy takes places with the help of microorganisms. The basic configuration of MFC consists of three major components such as electrodes (anode and cathode), catalyst (microorganism) and proton transport/exchange membrane (PEM). MFC classified into four types based on the substrate utilized for the catalytic energy conversion process such as Liquid-phase MFC, Solid-phase MFC, Plant-MFC and Algae-MFC. The core performance of MFC is organic substrate oxidation and electron transfer. Microorganisms and electrodes are the key factors that decide the efficiency of MFC system for electricity generation. Microorganism catalysis degradation of organic matters and assist the electron transfer to anode surface, the conductivity of anode material decides the rate of electron transport to cathode through external circuit where electrons are reduced with hydrogen and form water with oxygen. Not limited to electricity generation, MFC also has diverse applications in different sectors including wastewater treatment, biofuel (biohydrogen) production and used as biosensor for detection of biological oxygen demand (BOD) of wastewater and different contaminants concentration in water. This review explains different types of MFC systems and their core performance towards energy conversion and waste management. Also provides an insight on different factors that significantly affect the MFC performance and different aspects of application of MFC systems in various sectors. The challenges of MFC system design, operations and implementation in pilot scale level and the direction for future research are also described in the present review.
Collapse
Affiliation(s)
- A Saravanan
- Department of Energy and Environmental Engineering, Saveetha School of Engineering, SIMATS, Chennai, 602105, India
| | - P Senthil Kumar
- Department of Chemical Engineering, Sri Sivasubramaniya Nadar College of Engineering, Chennai, 603110, India; Centre of Excellence in Water Research (CEWAR), Sri Sivasubramaniya Nadar College of Engineering, Chennai, 603110, India.
| | - S Srinivasan
- Department of Biomedical Engineering, Saveetha School of Engineering, SIMATS, Chennai, 602105, India
| | - S Jeevanantham
- Department of Biotechnology, Rajalakshmi Engineering College, Chennai, Tamilnadu, 602105, India
| | - R Kamalesh
- Department of Biotechnology, Rajalakshmi Engineering College, Chennai, Tamilnadu, 602105, India
| | - S Karishma
- Department of Biotechnology, Rajalakshmi Engineering College, Chennai, Tamilnadu, 602105, India
| |
Collapse
|
25
|
Noori MT, Thatikayala D, Pant D, Min B. A critical review on microbe-electrode interactions towards heavy metal ion detection using microbial fuel cell technology. BIORESOURCE TECHNOLOGY 2022; 347:126589. [PMID: 34929327 DOI: 10.1016/j.biortech.2021.126589] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/31/2021] [Revised: 12/14/2021] [Accepted: 12/16/2021] [Indexed: 06/14/2023]
Abstract
Implicit interaction of electroactive microbes with solid electrodes is an interesting phenomenon in nature, which supported development of bioelectrochemical systems (BESs), especially the microbial fuel cell (MFCs) for valorization of low-value waste streams into bioelectricity. Intriguingly, the metabolism of interacted microbes with electrode is affected by the microenvironment at electrodes, which influences the current response. For instance, when heavy metal ions (HMIs) are imposed in the medium, the current production decreases due to their intrinsic toxic effect. This event provides an immense opportunity to utilize MFC as a sensor to selectively detect HMIs in the environment, which has been explored vastly in recent decade. In this review, we have concisely discussed the microbial interaction with electrodes and mechanism of detection of HMIs using an MFC. Recent advancement in sensing elements and their application is elaborated with a future perspective section for follow-up research and development in this field.
Collapse
Affiliation(s)
- Md Tabish Noori
- Department of Environmental Science and Engineering, Kyung Hee University - Global Campus, Gyeonggi-do 446-701, Republic of Korea
| | - Dayakar Thatikayala
- Department of Environmental Science and Engineering, Kyung Hee University - Global Campus, Gyeonggi-do 446-701, Republic of Korea
| | - Deepak Pant
- Separation & Conversion Technology, Flemish Institute for Technological Research (VITO), Boeretang 200, Mol 2400, Belgium
| | - Booki Min
- Department of Environmental Science and Engineering, Kyung Hee University - Global Campus, Gyeonggi-do 446-701, Republic of Korea.
| |
Collapse
|
26
|
Zang Y, Zhao H, Cao B, Xie B, Yi Y, Liu H. Enhancing the sensitivity of water toxicity detection based on suspended Shewanella oneidensis MR-1 by reversing extracellular electron transfer direction. Anal Bioanal Chem 2022; 414:3057-3066. [PMID: 35192018 DOI: 10.1007/s00216-022-03919-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2021] [Revised: 01/11/2022] [Accepted: 01/21/2022] [Indexed: 01/10/2023]
Abstract
Water toxicity detection is of great significance to ensure the safety of water supply. With suspended electrochemically active bacteria (EAB) as the sensing element, a novel microbial electrochemical sensor (MES) has recently been reported for the real-time detection of water toxicity, but its practical applications need to further improve the sensitivity. Extracellular electron transfer (EET) is an important factor affecting MES performance. In the study, the EET of suspended EAB-based MES was optimized to further enhance the sensitivity. Firstly, by using a model EAB stain Shewanella oneidensis MR-1, it was revealed that the sensitivity was increased at most 2.7 times with inward EET (i.e., cathodic polarization). Then, a novel conjecture based on electron transfer and energy fluxes was proposed and testified to explain this phenomenon. Finally, three key operating parameters of inward EET were orthogonally optimized. The optimized parameters of inward EET included a potential of - 0.5 V, a cell density of 1.8 × 108 CFU/mL, and an electron acceptor concentration of 15 mM.
Collapse
Affiliation(s)
- Yuxuan Zang
- Institute of Environmental Biology and Life Support Technology, School of Biological Science and Medical Engineering, Beihang University, No. 37, Xueyuan Road, Haidian District, Beijing, 100191, China.,International Joint Research Center of Aerospace Biotechnology and Medical Engineering, Beihang University, Beijing, 100191, China.,Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing, 100191, China
| | - Hongyu Zhao
- Institute of Environmental Biology and Life Support Technology, School of Biological Science and Medical Engineering, Beihang University, No. 37, Xueyuan Road, Haidian District, Beijing, 100191, China.,International Joint Research Center of Aerospace Biotechnology and Medical Engineering, Beihang University, Beijing, 100191, China.,Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing, 100191, China
| | - Bo Cao
- Institute of Environmental Biology and Life Support Technology, School of Biological Science and Medical Engineering, Beihang University, No. 37, Xueyuan Road, Haidian District, Beijing, 100191, China.,International Joint Research Center of Aerospace Biotechnology and Medical Engineering, Beihang University, Beijing, 100191, China.,Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing, 100191, China
| | - Beizhen Xie
- Institute of Environmental Biology and Life Support Technology, School of Biological Science and Medical Engineering, Beihang University, No. 37, Xueyuan Road, Haidian District, Beijing, 100191, China.,International Joint Research Center of Aerospace Biotechnology and Medical Engineering, Beihang University, Beijing, 100191, China.,Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing, 100191, China
| | - Yue Yi
- School of Life, Beijing Institute of Technology, No. 5, Zhongguancun South Street, Haidian District, Beijing, 100081, China.
| | - Hong Liu
- Institute of Environmental Biology and Life Support Technology, School of Biological Science and Medical Engineering, Beihang University, No. 37, Xueyuan Road, Haidian District, Beijing, 100191, China. .,International Joint Research Center of Aerospace Biotechnology and Medical Engineering, Beihang University, Beijing, 100191, China. .,Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing, 100191, China.
| |
Collapse
|
27
|
Dai Z, Yu R, Wu Y, Zhu G, Lu X, Zha X. Modelling of self-sustainable microbial fuel cell type oil sensors based on restricted oxygen transfer and two-population competition. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 806:151333. [PMID: 34740646 DOI: 10.1016/j.scitotenv.2021.151333] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/09/2021] [Revised: 10/07/2021] [Accepted: 10/26/2021] [Indexed: 06/13/2023]
Abstract
Oil leaks during oil industrial chain pose threats to the ecosystem. The microbial fuel cell-type oil sensor has been developed for early warning of such issues. Oil contacting with the sensor restricts oxygen availability and triggers correlative signal anomaly which serves as indicative of the oil presence. To extend its application for the real world, modelling of the sensor is required to pre-describe the signal behavior under unknown conditions. Therefore, by integrating Butler-Volmer, restricted oxygen transfer (ROT) and Monod equations, a dynamic ROT-MFC model with sufficient substrate precondition was developed. The ROT-MFC model was trained on the experimental single-oil-shock test (R 2 = 0.996) and validated by the experimental sequential-shocktest (R 2 = 0.998). Numerical analysis of the trained ROT-MFC model indicates that the single-shock detection has higher sensitivity (≥40.6 mV/detection) and the sequential-shocks detection spends a shorter response time (≤2.2 h). Besides, the sequential-shocks detection with proper strategy is more applicable due to flexible options on detection limit and working range. The model was further evolved into the TPC-ROT-MFC model by introducing a two-population competition (TPC) theory to describe performance under limited substrate conditions. Results indicate a critical substrate concentration range (42.1 to 62.8 mg-COD/L) for dividing baseline steadiness, and that the impact of substrate concentration on anodic charge transfer coefficient soars when the substrate concentration lessens furtherly. This sensor model is relatively easy to implement and may enhance practical use for design and operation.
Collapse
Affiliation(s)
- Zheqin Dai
- School of Energy and Environment, Southeast University, No.2 Sipailou Road, Nanjing 210096, PR China; ERC Taihu Lake Water Environment (Wuxi), No. 99 Linghu Road, Wuxi 214135, PR China
| | - Ran Yu
- School of Energy and Environment, Southeast University, No.2 Sipailou Road, Nanjing 210096, PR China
| | - Yifeng Wu
- School of Energy and Environment, Southeast University, No.2 Sipailou Road, Nanjing 210096, PR China
| | - Guangcan Zhu
- School of Energy and Environment, Southeast University, No.2 Sipailou Road, Nanjing 210096, PR China
| | - Xiwu Lu
- School of Energy and Environment, Southeast University, No.2 Sipailou Road, Nanjing 210096, PR China; ERC Taihu Lake Water Environment (Wuxi), No. 99 Linghu Road, Wuxi 214135, PR China.
| | - Xiao Zha
- School of Environmental Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, PR China
| |
Collapse
|
28
|
Chu N, Cai J, Li Z, Gao Y, Liang Q, Hao W, Liu P, Jiang Y, Zeng RJ. Indicators of water biotoxicity obtained from turn-off microbial electrochemical sensors. CHEMOSPHERE 2022; 286:131725. [PMID: 34352539 DOI: 10.1016/j.chemosphere.2021.131725] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/27/2021] [Revised: 07/15/2021] [Accepted: 07/28/2021] [Indexed: 06/13/2023]
Abstract
The development of biosensors is critical to reducing potential risks associated with contamination accidents. However, the application of microbial electrochemical sensors for water biotoxicity monitoring is hampered by the lack of an indicator with high response magnitudes. In this study, microbial electrochemical sensors were fabricated with interdigitated electrode arrays (IDAs), and indicators from various electrochemical analyses were comprehensively investigated. Only the peak of cyclic voltammetry (CV) was highly linearly correlated with the commonly used current indicator during the enrichment of the electroactive biofilm. The resistance fitted from the electrochemical impedance spectroscopy (EIS) data provided a comparable and even higher inhibition ratio (IR) than the current during toxicity assessments. The differential pulse voltammetry (DPV) did not exhibit a higher sensitivity than the CV peak. However, no clear response was observed in the real-time impedance analysis for use in water biotoxicity monitoring. Most of the microbes were in the propidium iodide (PI)-permeable state after the toxicity assessments, although the current was fully recovered. This study demonstrates the potential to use EIS data as indicators of water biotoxicity using microbial electrochemical sensors.
Collapse
Affiliation(s)
- Na Chu
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian, 350002, China
| | - Jiayi Cai
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian, 350002, China
| | - Zhigang Li
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian, 350002, China
| | - Yu Gao
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian, 350002, China
| | - Qinjun Liang
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian, 350002, China
| | - Wen Hao
- State Key Joint Laboratory of Environment Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing, 100084, China
| | - Panpan Liu
- School of Ecology and Environment, Zhengzhou University, Zhengzhou, Henan, 450001, China
| | - Yong Jiang
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian, 350002, China.
| | - Raymond Jianxiong Zeng
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian, 350002, China
| |
Collapse
|
29
|
Mohamed A, Ha PT, Beyenal H. Kinetics and scale up of oxygen reducing cathodic biofilms. Biofilm 2021; 3:100053. [PMID: 34308331 PMCID: PMC8283157 DOI: 10.1016/j.bioflm.2021.100053] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2021] [Revised: 05/05/2021] [Accepted: 06/01/2021] [Indexed: 11/30/2022] Open
Abstract
The goals of this work were to study the kinetics and investigate the factors controlling the scale up of oxygen reducing mixed culture cathodic biofilms. Cathodic biofilms were enriched on different electrode sizes (14.5 cm2, 40.3 cm2, 131 cm2 and 466 cm2). Biofilm enrichment shifted the oxygen reduction onset potential from -0.1 VAg/AgCl to 0.3 VAg/AgCl, indicating the biofilm catalyzed oxygen reduction. The kinetics of oxygen reduction were studied by varying the bulk dissolved oxygen concentration. Oxygen reduction followed a Michaelis-Menten kinetics on all electrode sizes. The maximum current density decreased with increasing electrode surface area (-97.0 ± 10.6 μA/cm2, -76.0 ± 8.2 μA/cm2, -66.3 ± 3.0 μA/cm2 and -43.5 ± 10.5 μA/cm2, respectively). Cyclic voltammograms suggest that scale up was limited by ohmic resistance, likely due to the low ionic conductivity in the wastewater medium. Mathematical modeling using combined Michaelis-Menten and Butler-Volmer model supports that the decrease in current density with increasing electrode surface area is caused by ohmic losses. Analysis of the microbial community structure in different size electrodes and in multiple regions on the same electrode showed low variability, suggesting that the microbial community does not control the scale up of cathodic biofilms.
Collapse
Affiliation(s)
- Abdelrhman Mohamed
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA, USA
| | - Phuc T. Ha
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA, USA
| | - Haluk Beyenal
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA, USA
| |
Collapse
|
30
|
Dai Z, Yu R, Zha X, Xu Z, Zhu G, Lu X. On-line monitoring of minor oil spills in natural waters using sediment microbial fuel cell sensors equipped with vertical floating cathodes. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 782:146549. [PMID: 33839652 DOI: 10.1016/j.scitotenv.2021.146549] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/03/2020] [Revised: 03/02/2021] [Accepted: 03/13/2021] [Indexed: 05/22/2023]
Abstract
Oil spills near natural water bodies pose considerable threats to aquatic ecosystem and drinking water system. Various detection techniques have been developed to identify the oil pollution in natural waters. These techniques mainly focus on large and major oil spills involving significant changes in environmental characteristics. However, monitoring of minor oil spills (from seepage and dripping) in waters remains a bottleneck, allowing inconspicuous and persistent oil contamination. To overcome this drawback, a sediment microbial fuel cell (SMFC) sensor equipped with a vertical floating cathode is developed for on-line and in-situ monitoring of minor oil spills in natural waters. The vertical floating cathode was intended for recognizing oil on water surface. Oil on the cathode will trigger current drop. Two kinds of natural sediments were adopted in two sensors (SMFC1 from a lake and SMFC2 from an urban stream) for comparison. Both showed linear relationship between net steady-state current decrease and oil dose (30.78 and 27.29 μA/mL of sensitivity, respectively). The current change process was fitted well to a pseudo-first order kinetic equation. A one-point/two-point dynamic identification methods were derived from the kinetic equation. Therefore, the detection time was shortened from 10 h to 10/30 min. The triggered current decrease was mainly attributed to the increase in internal resistance related to charge and mass transfer. Despite the power loss after oil contamination, results implied SMFC sensor could still achieve self-sustainability. This study shows that the SMFC sensor with vertical floating cathodes is applicable to monitoring the unnoticeable minor oil pollutions in natural waters.
Collapse
Affiliation(s)
- Zheqin Dai
- School of Energy and Environment, Southeast University, No.2 Sipailou Road, Nanjing 210096, PR China; ERC Taihu Lake Water Environment (Wuxi), No. 99 Linghu Road, Wuxi 214135, PR China
| | - Ran Yu
- School of Energy and Environment, Southeast University, No.2 Sipailou Road, Nanjing 210096, PR China
| | - Xiao Zha
- School of Energy and Environment, Southeast University, No.2 Sipailou Road, Nanjing 210096, PR China; ERC Taihu Lake Water Environment (Wuxi), No. 99 Linghu Road, Wuxi 214135, PR China
| | - Zhiheng Xu
- Department of Civil & Environmental Engineering, University of Connecticut, Storrs, CT 06269, United States
| | - Guangcan Zhu
- School of Energy and Environment, Southeast University, No.2 Sipailou Road, Nanjing 210096, PR China
| | - Xiwu Lu
- School of Energy and Environment, Southeast University, No.2 Sipailou Road, Nanjing 210096, PR China; ERC Taihu Lake Water Environment (Wuxi), No. 99 Linghu Road, Wuxi 214135, PR China.
| |
Collapse
|
31
|
Chung TH, Dhar BR. Paper-based platforms for microbial electrochemical cell-based biosensors: A review. Biosens Bioelectron 2021; 192:113485. [PMID: 34274625 DOI: 10.1016/j.bios.2021.113485] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2021] [Revised: 06/30/2021] [Accepted: 07/02/2021] [Indexed: 12/13/2022]
Abstract
The development of low-cost analytical devices for on-site water quality monitoring is a critical need, especially for developing countries and remote communities in developed countries with limited resources. Microbial electrochemical cell-based (MXC) biosensors have been quite promising for quantitative and semi-quantitative (often qualitative) measurements of various water quality parameters due to their low cost and simplicity compared to traditional analytical methods. However, conventional MXC biosensors often encounter challenges, such as the slow establishment of biofilms, low sensitivity, and poor recoverability, making them unable to be applied for practical cases. In response, MXC biosensors assembled with paper-based materials demonstrated tremendous potentials to enhance sensitivity and field applicability. Furthermore, the paper-based platforms offer many prominent features, including autonomous liquid transport, rapid bacterial adhesion, lowered resistance, low fabrication cost (<$1 in USD), and eco-friendliness. Therefore, this review aims to summarize the current trend and applications of paper-based MXC biosensors, along with critical discussions on their field applicability. Moreover, future advancements of paper-based MXC biosensors, such as developing a novel paper-based biobatteries, increasing the system performance using an unique biocatalyst, such as yeast, and integrating the biosensor system with other advanced tools, such as machine learning and 3D printing, are highlighted.
Collapse
Affiliation(s)
- Tae Hyun Chung
- Department of Civil and Environmental Engineering, University of Alberta, 9211-116 Street NW, Edmonton, AB, T6G 1H9, Canada
| | - Bipro Ranjan Dhar
- Department of Civil and Environmental Engineering, University of Alberta, 9211-116 Street NW, Edmonton, AB, T6G 1H9, Canada.
| |
Collapse
|
32
|
Xing F, Xi H, Yu Y, Zhou Y. Anode biofilm influence on the toxic response of microbial fuel cells under different operating conditions. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 775:145048. [PMID: 33631591 DOI: 10.1016/j.scitotenv.2021.145048] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/14/2020] [Revised: 01/03/2021] [Accepted: 01/04/2021] [Indexed: 06/12/2023]
Abstract
The response of microorganisms in microbial fuel cells (MFCs) to toxic compounds under different operating conditions, such as flow rate and culture time, was investigated herein. While it has been reported that MFCs can detect some toxic substances, it is unclear if operating conditions affect MFCs toxicity response. In this study, the toxic response time of MFCs decreased when the flow rate increased from 0.5 mL/min to 2 mL/min and then increased with 5 mL/min. The inhibition rates at 0.5 mL/min, 2 mL/min, and 5 mL/min were 8.4% ± 1.6%, 45.1% ± 5.3%, and 4.9% ± 0.3%, respectively. With the increase of culture time from 7 days to 90 days, the toxic response time of MFCs gradually increased. The inhibition rates at culture times of 7 days, 45 days, and 90 days were 45.1% ± 5.3%, 32.6% ± 6.6%, and 23.2% ± 1.3%, respectively. Increasing the culture time will reduce the sensitivity of MFC. The results showed that MFCs can respond quickly at a flow rate of 2 mL/min after cultivation for 7 days. Under these conditions, the power density can reach 1137.0 ± 65.5 mW/m2, the relative content of Geobacter sp. is 57%, and the ORP of the multilayers changed from -159.2 ± 1.6 mV to -269.9 ± 1.7 mV within 200 μm biofilm thickness. These findings show that increasing the flow rate and shortening the culture time are conducive for the toxicity response of MFCs, which will increase the sensitivity of MFCs in practical applications.
Collapse
Affiliation(s)
- Fei Xing
- College of Water Sciences, Beijing Normal University, Beijing 100875, PR China; State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Beijing 100012, PR China
| | - Hongbo Xi
- State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Beijing 100012, PR China
| | - Yin Yu
- State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Beijing 100012, PR China.
| | - Yuexi Zhou
- State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Beijing 100012, PR China.
| |
Collapse
|
33
|
Olias LG, Di Lorenzo M. Microbial fuel cells for in-field water quality monitoring. RSC Adv 2021; 11:16307-16317. [PMID: 35479166 PMCID: PMC9031575 DOI: 10.1039/d1ra01138c] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2021] [Accepted: 04/23/2021] [Indexed: 12/13/2022] Open
Abstract
The need for water security pushes for the development of sensing technologies that allow online and real-time assessments and are capable of autonomous and stable long-term operation in the field. In this context, Microbial Fuel Cell (MFC) based biosensors have shown great potential due to cost-effectiveness, simplicity of operation, robustness and the possibility of self-powered applications. This review focuses on the progress of the technology in real scenarios and in-field applications and discusses the technological bottlenecks that must be overcome for its success. An overview of the most relevant findings and challenges of MFC sensors for practical implementation is provided. First, performance indicators for in-field applications, which may diverge from lab-based only studies, are defined. Progress on MFC designs for off-grid monitoring of water quality is then presented with a focus on solutions that enhance robustness and long-term stability. Finally, calibration methods and detection algorithms for applications in real scenarios are discussed.
Collapse
Affiliation(s)
- Lola Gonzalez Olias
- Centre for Biosensors, Bioelectronics and Biodevices (C3Bio) and Department of Chemical Engineering, University of Bath Bath BA2 7AY UK
- Water Innovation Research Centre (WIRC), University of Bath Bath BA2 7AY UK
| | - Mirella Di Lorenzo
- Centre for Biosensors, Bioelectronics and Biodevices (C3Bio) and Department of Chemical Engineering, University of Bath Bath BA2 7AY UK
| |
Collapse
|
34
|
Li T, Liao C, An J, Zhou L, Tian L, Zhou Q, Li N, Wang X. A highly sensitive bioelectrochemical toxicity sensor and its evaluation using immediate current attenuation. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 766:142646. [PMID: 33066964 DOI: 10.1016/j.scitotenv.2020.142646] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Revised: 09/14/2020] [Accepted: 09/18/2020] [Indexed: 06/11/2023]
Abstract
Electroactive biofilm (EAB) sensor had shown great potential in the field of early warning of toxicants in water because of the low-cost and broad-spectrum. However, the traditional calculation of sensitivity strongly relied on the time and concentration gradient which weakened time-efficiency of the sensor. Moreover, the sensitivity could be further improved to respond trace concentrations. Here EAB sensors with different substrate concentrations were formed to respond different concentrations formaldehyde ranging from 1 ppm to 50 ppm and immediate current attenuation (ICA) was induced to evaluate the sensitivity. The ICA (~70 s) exhibited a shorter time than that calculated by calculable sensitivity (CS) and current attenuation (CA), which not only achieved the response of trace concentration but also improved the time-efficiency of the sensor. The EAB formed with 0.1 g/L acetate (EAB-0.1) had a 380% higher sensitivity than that formed with 1.0 g/L acetate (EAB-1.0), leading to a significant electrochemical toxicity response to 1 ppm of formaldehyde. The results of electrochemical response coefficient confirmed that EAB-0.1 was 1.5-6.3 times of that formed with acetate from 0.2 to 1.0 g/L, which was related with microbial community and component of EAB as described in our previous study. Our findings demonstrated that calculation of sensitivity could be optimized to reflect time-efficiency and EAB with limit acetate could be applied in trace toxicant detection.
Collapse
Affiliation(s)
- Tian Li
- MOE Key Laboratory of Pollution Processes and Environmental Criteria/Tianjin Key Laboratory of Environmental Remediation and Pollution Control/College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin 300350, China
| | - Chengmei Liao
- MOE Key Laboratory of Pollution Processes and Environmental Criteria/Tianjin Key Laboratory of Environmental Remediation and Pollution Control/College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin 300350, China
| | - Jingkun An
- School of Environmental Science and Engineering, Tianjin University, No. 92 Weijin Road, Nankai District, Tianjin 300072, China
| | - Lean Zhou
- MOE Key Laboratory of Pollution Processes and Environmental Criteria/Tianjin Key Laboratory of Environmental Remediation and Pollution Control/College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin 300350, China
| | - Lili Tian
- MOE Key Laboratory of Pollution Processes and Environmental Criteria/Tianjin Key Laboratory of Environmental Remediation and Pollution Control/College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin 300350, China
| | - Qixing Zhou
- MOE Key Laboratory of Pollution Processes and Environmental Criteria/Tianjin Key Laboratory of Environmental Remediation and Pollution Control/College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin 300350, China
| | - Nan Li
- School of Environmental Science and Engineering, Tianjin University, No. 92 Weijin Road, Nankai District, Tianjin 300072, China
| | - Xin Wang
- MOE Key Laboratory of Pollution Processes and Environmental Criteria/Tianjin Key Laboratory of Environmental Remediation and Pollution Control/College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin 300350, China.
| |
Collapse
|
35
|
Chu N, Liang Q, Hao W, Jiang Y, Zeng RJ. Micro-microbial electrochemical sensor equipped with combined bioanode and biocathode for water biotoxicity monitoring. BIORESOURCE TECHNOLOGY 2021; 326:124743. [PMID: 33503515 DOI: 10.1016/j.biortech.2021.124743] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/09/2020] [Revised: 01/12/2021] [Accepted: 01/15/2021] [Indexed: 06/12/2023]
Abstract
The development of low-cost biosensors for water monitoring is expected to reduce potential risks from contamination accidents. This study reported a novel micro-microbial electrochemical sensor using combined bioanode and biocathode as the sensing element, characterized by a sequential flowing membrane-free channel and a bilateral passive oxygen supply. A decrease in the ratio of number of bioanode to biocathode resulted in a lower power generation, whereas, achieving a similar or even higher toxic response. The voltage was affected by both the flow rate and the acetate concentration. With the increased acetate concentration, a clear trade-off was observed between the electroactivity stimulation of bioanode vs. the electroactivity maintenance of biocathode. Biosensors made good response to the injection of formaldehyde (10 µL of 0.25%, and 100 µL of 0.025%) into the inlet. A high microbial diversity was observed. This work can lead to a revolutionizing way of water monitoring using self-powered micro-biosensors.
Collapse
Affiliation(s)
- Na Chu
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian 350002, China
| | - Qinjun Liang
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian 350002, China
| | - Wen Hao
- State Key Joint Laboratory of Environment Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing 100084, China
| | - Yong Jiang
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian 350002, China.
| | - Raymond Jianxiong Zeng
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian 350002, China
| |
Collapse
|
36
|
Adekunle A, Gomez Vidales A, Woodward L, Tartakovsky B. Microbial fuel cell soft sensor for real-time toxicity detection and monitoring. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2021; 28:12792-12802. [PMID: 33089465 DOI: 10.1007/s11356-020-11245-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/16/2020] [Accepted: 10/12/2020] [Indexed: 06/11/2023]
Abstract
Real-time toxicity detection and monitoring using a microbial fuel cell (MFC) is often based on observing current or voltage changes. Other methods of obtaining more information on the internal state of the MFC, such as electrochemical impedance spectroscopy (EIS), are invasive, disruptive, time consuming, and may affect long-term MFC performance. This study proposes a soft sensor approach as a non-invasive real-time method for evaluating the internal state of an MFC biosensor during toxicity monitoring. The proposed soft sensor approach is based on estimating the equivalent circuit model (ECM) parameters in real time. A flow-through MFC biosensor was operated at several combinations of carbon source (acetate) and toxicant (copper) concentrations. The ECM parameters, such as internal resistance, capacitance, and open-circuit voltage, were estimated in real time using a numerical parameter estimation procedure. The soft sensor approach proved to be an adequate replacement for EIS measurements in quantifying changes in the biosensor internal parameters. The approach also provided additional information, which could lead to earlier detection of the toxicity onset.
Collapse
Affiliation(s)
- Ademola Adekunle
- National Research Council of Canada, 6100 Royalmount Ave, Montreal, QC, H4P 2R2, Canada
| | - Abraham Gomez Vidales
- National Research Council of Canada, 6100 Royalmount Ave, Montreal, QC, H4P 2R2, Canada
| | - Lyne Woodward
- École de Technologie Supérieure, 1100 Notre-Dame St W, Montreal, QC, H3C 1K3, Canada
| | - Boris Tartakovsky
- National Research Council of Canada, 6100 Royalmount Ave, Montreal, QC, H4P 2R2, Canada.
| |
Collapse
|
37
|
Yu YY, Ding XL, Quan WZ, Niu Q, Fang Z, Dapaah MF, You T, Xiao X, Cheng L. Dynamically controlling the electrode potential of a microbial fuel cell-powered biocathode for sensitive quantification of nitrate. Electrochim Acta 2021. [DOI: 10.1016/j.electacta.2020.137661] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
38
|
Qi X, Liu P, Liang P, Hao W, Li M, Li Q, Zhou Y, Huang X. Biofilm's morphology design for high sensitivity of bioelectrochemical sensor: An experimental and modeling study. THE SCIENCE OF THE TOTAL ENVIRONMENT 2020; 729:138908. [PMID: 32361449 DOI: 10.1016/j.scitotenv.2020.138908] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/16/2020] [Revised: 04/20/2020] [Accepted: 04/20/2020] [Indexed: 06/11/2023]
Abstract
High sensitivity is essential for the application of bioelectrochemical system-based sensor (BES sensor) in water quality early-warning, where the electroactive biofilm is of vital importance as it delivers a responsive electric signal to toxic substances. This study artificially designed the morphology of a naturally formed biofilm by employing a serrated knife to scrape the biofilm and thus obtained a reduced thickness and roughness. Then it was further cut by half to halve the biomass. BES sensors equipped with control and processed biofilms were operated under constant anode potential (CAP) and tested at different Cu(II) concentrations to study their sensitivities. Results revealed that the scraped biofilms delivered much increased sensitivity towards Cu(II) shock, which was attributed to a reduced thickness as illustrated by macroscopic and microscopic morphology analysis. Another finding was that biomass per unit interfacial area, rather than the biomass, also affected the sensitivity. To further describe how the inner biofilm responded the toxicity after morphology design, a one-dimension mass transfer model was developed to simulate the mass transfer of Cu(II) in the biofilms with different thicknesses. The relative threshold value of inlet Cu(II) concentration was employed to fit the modeling and experimental results, indicating that decreased biofilm thickness was beneficial for improving the sensitivity.
Collapse
Affiliation(s)
- Xiang Qi
- State Key Joint Laboratory of Environment Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing 100084, China
| | - Panpan Liu
- State Key Joint Laboratory of Environment Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing 100084, China
| | - Peng Liang
- State Key Joint Laboratory of Environment Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing 100084, China.
| | - Wen Hao
- State Key Joint Laboratory of Environment Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing 100084, China
| | - Meng Li
- State Key Joint Laboratory of Environment Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing 100084, China
| | - Qingchen Li
- State Key Joint Laboratory of Environment Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing 100084, China
| | - Yuexi Zhou
- State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Beijing, 100012, China
| | - Xia Huang
- State Key Joint Laboratory of Environment Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing 100084, China
| |
Collapse
|
39
|
Liu W, Jia H, Jiang X, Wu Y, Wang J. The new insight about electrode interface behaviour via in situ ultrasound three-dimensional representation monitoring based on a bio-electrochemical system. Bioelectrochemistry 2020; 136:107599. [PMID: 32711364 DOI: 10.1016/j.bioelechem.2020.107599] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Revised: 07/12/2020] [Accepted: 07/12/2020] [Indexed: 12/26/2022]
Abstract
Behaviour of the electrode interface is a determining factor that affects the performance of a bio-electrochemical system (BES). Examples include the formation of an electroactive biofilm, electrode degradation and renewal. However, underlying mechanisms are unclear, and traditional approaches make it difficult to achieve in situ monitoring. In this study, a novel technology using ultrasound three-dimensional representation (UTDR) was used to track in situ electrode interface behaviour based on the correspondence between acoustic and electrical signals. A series of wavelet analyses showed that the formation of an electroactive biofilm is a lengthy process with multiple physiological steps, and biofilm thickness increased by approximately 600 μm after 40 days of operation. At the same time, directional migration of Ca2+, Mg2+ confirmed acceleration of the salting out on the cathode, which forms a compacted structure with the biological layer. Furthermore, UTDR combined with electrochemical methods allowed for comprehensive evaluation of AC impact, and indicated that AC (1 Hz, 20 V) could effectively desquamate the contaminating solids and restore power density to 93.4% of initial. These results show that UTDR is a sensitive and effective method for revealing microscopic changes on the electrode surface, which gives it potential wide applicability to interfacial processes.
Collapse
Affiliation(s)
- Wenbin Liu
- State Key Laboratory of Separation Membrane and Membrane Processes, Tianjin TianGong University, Tianjin 300387, China; School of Environmental Science and Engineering, Tianjin TianGong University, Tianjin 300387, China; State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, 73 Huanghe Road, Harbin 150090, China
| | - Hui Jia
- State Key Laboratory of Separation Membrane and Membrane Processes, Tianjin TianGong University, Tianjin 300387, China; School of Environmental Science and Engineering, Tianjin TianGong University, Tianjin 300387, China
| | - Xin Jiang
- State Key Laboratory of Separation Membrane and Membrane Processes, Tianjin TianGong University, Tianjin 300387, China; School of Environmental Science and Engineering, Tianjin TianGong University, Tianjin 300387, China
| | - Yun Wu
- State Key Laboratory of Separation Membrane and Membrane Processes, Tianjin TianGong University, Tianjin 300387, China; School of Environmental Science and Engineering, Tianjin TianGong University, Tianjin 300387, China
| | - Jie Wang
- State Key Laboratory of Separation Membrane and Membrane Processes, Tianjin TianGong University, Tianjin 300387, China; School of Environmental Science and Engineering, Tianjin TianGong University, Tianjin 300387, China.
| |
Collapse
|
40
|
Uria N, Fiset E, Pellitero MA, Muñoz F, Rabaey K, Campo F. Immobilisation of electrochemically active bacteria on screen-printed electrodes for rapid in situ toxicity biosensing. ENVIRONMENTAL SCIENCE AND ECOTECHNOLOGY 2020; 3:100053. [PMID: 36159604 PMCID: PMC9488082 DOI: 10.1016/j.ese.2020.100053] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Revised: 07/07/2020] [Accepted: 07/07/2020] [Indexed: 06/12/2023]
Abstract
Microbial biosensors can be an excellent alternative to classical methods for toxicity monitoring, which are time-consuming and not sensitive enough. However, bacteria typically connect to electrodes through biofilm formation, leading to problems due to lack of uniformity or long device production times. A suitable immobilisation technique can overcome these challenges. Still, they may respond more slowly than biofilm-based electrodes because bacteria gradually adapt to electron transfer during biofilm formation. In this study, we propose a controlled and reproducible way to fabricate bacteria-modified electrodes. The method consists of an immobilisation step using a cellulose matrix, followed by an electrode polarization in the presence of ferricyanide and glucose. Our process is short, reproducible and led us to obtain ready-to-use electrodes featuring a high-current response. An excellent shelf-life of the immobilised electrochemically active bacteria was demonstrated for up to one year. After an initial 50% activity loss in the first month, no further declines have been observed over the following 11 months. We implemented our bacteria-modified electrodes to fabricate a lateral flow platform for toxicity monitoring using formaldehyde (3%). Its addition led to a 59% current decrease approximately 20 min after the toxic input. The methods presented here offer the ability to develop a high sensitivity, easy to produce, and long shelf life bacteria-based toxicity detectors.
Collapse
Affiliation(s)
- N. Uria
- Institut de Microelectrònica de Barcelona, IMB-CNM (CSIC), 08193, Esfera UAB, 08193, Bellaterra, Barcelona, Spain
- Arkyne Technologies SL (Bioo) ES-B90229261, Carrer de La Tecnologia, 17, 08840, Viladecans, Barcelona, Spain
| | - E. Fiset
- Center for Microbial Ecology and Technology (CMET) – FBE – Ghent University, Ghent, Belgium
| | - M. Aller Pellitero
- Institut de Microelectrònica de Barcelona, IMB-CNM (CSIC), 08193, Esfera UAB, 08193, Bellaterra, Barcelona, Spain
| | - F.X. Muñoz
- Institut de Microelectrònica de Barcelona, IMB-CNM (CSIC), 08193, Esfera UAB, 08193, Bellaterra, Barcelona, Spain
| | - K. Rabaey
- Center for Microbial Ecology and Technology (CMET) – FBE – Ghent University, Ghent, Belgium
- CAPTURE, Belgium
| | - F.J.del Campo
- Institut de Microelectrònica de Barcelona, IMB-CNM (CSIC), 08193, Esfera UAB, 08193, Bellaterra, Barcelona, Spain
| |
Collapse
|
41
|
Li T, Zhou Q, Zhou L, Yan Y, Liao C, Wan L, An J, Li N, Wang X. Acetate limitation selects Geobacter from mixed inoculum and reduces polysaccharide in electroactive biofilm. WATER RESEARCH 2020; 177:115776. [PMID: 32294591 DOI: 10.1016/j.watres.2020.115776] [Citation(s) in RCA: 55] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/22/2019] [Revised: 02/18/2020] [Accepted: 03/31/2020] [Indexed: 06/11/2023]
Abstract
Bioelectrochemical systems (BESs) are widely investigated as a promising technology to recover bioenergy or synthesize value-added products from wastewaters. The performance of BES depends on the activity of electroactive biofilm (EAB). As the core of BES, it is still unclear how the EAB is formed from mixed inoculum, and how exoelectrogens compete with non-exoelectrogens. Here we confirmed that microbial community composition and the morphology of EAB on the electrode including the thickness and porosity of the biofilm are critical for the performance of BES, and these properties can be simply controlled by the substrate concentration during EAB formation. The EAB formed with 0.1 g/L of acetate (EAB-0.1) exhibited a 90% higher current density than that formed with 1.0 g/L acetate (EAB-1.0). EAB-0.1 had a 50% higher electroactivity per biomass and a 20% thinner thickness than EAB-1.0, which was partly due to the 54% decrease of insulative polysaccharide in biofilm. Limited acetate also imposed a selective pressure to enrich Geobacter up to 88% compared to 72% when acetate was abundant. Our findings demonstrate that a highly active EAB can be formed by limiting substrate concentration, providing a broader understanding of the EAB formation process, the ecology of interspecies competitions and potential applications for bioenergy recovery and trace toxicant detection in the future.
Collapse
Affiliation(s)
- Tian Li
- MOE Key Laboratory of Pollution Processes and Environmental Criteria / Tianjin Key Laboratory of Environmental Remediation and Pollution Control / College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin, 300350, China
| | - Qixing Zhou
- MOE Key Laboratory of Pollution Processes and Environmental Criteria / Tianjin Key Laboratory of Environmental Remediation and Pollution Control / College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin, 300350, China
| | - Lean Zhou
- MOE Key Laboratory of Pollution Processes and Environmental Criteria / Tianjin Key Laboratory of Environmental Remediation and Pollution Control / College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin, 300350, China
| | - Yuqing Yan
- MOE Key Laboratory of Pollution Processes and Environmental Criteria / Tianjin Key Laboratory of Environmental Remediation and Pollution Control / College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin, 300350, China
| | - Chengmei Liao
- MOE Key Laboratory of Pollution Processes and Environmental Criteria / Tianjin Key Laboratory of Environmental Remediation and Pollution Control / College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin, 300350, China
| | - Lili Wan
- MOE Key Laboratory of Pollution Processes and Environmental Criteria / Tianjin Key Laboratory of Environmental Remediation and Pollution Control / College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin, 300350, China
| | - Jingkun An
- School of Environmental Science and Engineering, Tianjin University, No. 92 Weijin Road, Nankai District, Tianjin, 300072, China
| | - Nan Li
- School of Environmental Science and Engineering, Tianjin University, No. 92 Weijin Road, Nankai District, Tianjin, 300072, China
| | - Xin Wang
- MOE Key Laboratory of Pollution Processes and Environmental Criteria / Tianjin Key Laboratory of Environmental Remediation and Pollution Control / College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin, 300350, China.
| |
Collapse
|
42
|
Liu W, Yang G, Jia H, Wang J. A novel UASB-MFC dual sensors system for wastewater treatment: On-line sensor recovery and electrode cleaning in the long-term operation. CHEMOSPHERE 2020; 246:125751. [PMID: 31896017 DOI: 10.1016/j.chemosphere.2019.125751] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2019] [Revised: 11/24/2019] [Accepted: 12/24/2019] [Indexed: 06/10/2023]
Abstract
In this research, the UASB-MFC dual sensors system was established and treatment the brewery wastewater. The COD removal rate attain about 90% and the NH4+-N concentration less than 15 mg/L, MFCs has a voltage range of 0.34-0.42 V. Meanwhile, as the biosensor for coupling system, MFCs can be used to make simultaneous monitor COD and TVFA. The potential distribution can in-situ accelerate the reattachment of micro-organisms, which shorten the recovery time to 55% of the original. The long-term performance of MFCs were tested by electrochemical methods and found that the degradation of biosensors was mainly caused by the precipitation of Ca2+ and Mg2+ on the cathode surface and affected by concentration. More importantly, cleaning the electrode by an self-enhanced method without external assistance ECS (Electrodes Connection Switching) can improve the MFCs performance to 83.2 %-84.6%. Dual sensors system in UASB gives a novel possibility for UASB-MFC sensor self-sustaining in a long-term.
Collapse
Affiliation(s)
- Wenbin Liu
- State Key Laboratory of Separation Membranes and Membrane Processes, Tianjin Polytechnic University, Tianjin, 300387, China; School of Environmental and Chemical Engineering, Tianjin Polytechnic University, Tianjin, 300387, China
| | - Guang Yang
- School of Environmental Science and Engineering, Tianjin University, Tianjin, 300072, China
| | - Hui Jia
- State Key Laboratory of Separation Membranes and Membrane Processes, Tianjin Polytechnic University, Tianjin, 300387, China; School of Environmental and Chemical Engineering, Tianjin Polytechnic University, Tianjin, 300387, China
| | - Jie Wang
- State Key Laboratory of Separation Membranes and Membrane Processes, Tianjin Polytechnic University, Tianjin, 300387, China; School of Environmental and Chemical Engineering, Tianjin Polytechnic University, Tianjin, 300387, China.
| |
Collapse
|
43
|
Integrated Electrochemical Biosensors for Detection of Waterborne Pathogens in Low-Resource Settings. BIOSENSORS-BASEL 2020; 10:bios10040036. [PMID: 32294961 PMCID: PMC7236604 DOI: 10.3390/bios10040036] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/29/2020] [Revised: 03/21/2020] [Accepted: 04/05/2020] [Indexed: 12/24/2022]
Abstract
More than 783 million people worldwide are currently without access to clean and safe water. Approximately 1 in 5 cases of mortality due to waterborne diseases involve children, and over 1.5 million cases of waterborne disease occur every year. In the developing world, this makes waterborne diseases the second highest cause of mortality. Such cases of waterborne disease are thought to be caused by poor sanitation, water infrastructure, public knowledge, and lack of suitable water monitoring systems. Conventional laboratory-based techniques are inadequate for effective on-site water quality monitoring purposes. This is due to their need for excessive equipment, operational complexity, lack of affordability, and long sample collection to data analysis times. In this review, we discuss the conventional techniques used in modern-day water quality testing. We discuss the future challenges of water quality testing in the developing world and how conventional techniques fall short of these challenges. Finally, we discuss the development of electrochemical biosensors and current research on the integration of these devices with microfluidic components to develop truly integrated, portable, simple to use and cost-effective devices for use by local environmental agencies, NGOs, and local communities in low-resource settings.
Collapse
|
44
|
Lazzarini Behrmann IC, Grattieri M, Minteer SD, Ramirez SA, Vullo DL. Online self-powered Cr(VI) monitoring with autochthonous Pseudomonas and a bio-inspired redox polymer. Anal Bioanal Chem 2020; 412:6449-6457. [DOI: 10.1007/s00216-020-02620-w] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2020] [Revised: 03/24/2020] [Accepted: 03/26/2020] [Indexed: 12/11/2022]
|
45
|
Li T, Chen F, Zhou Q, Wang X, Liao C, Zhou L, Wan L, An J, Wan Y, Li N. Unignorable toxicity of formaldehyde on electroactive bacteria in bioelectrochemical systems. ENVIRONMENTAL RESEARCH 2020; 183:109143. [PMID: 32028180 DOI: 10.1016/j.envres.2020.109143] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/08/2019] [Revised: 12/31/2019] [Accepted: 01/14/2020] [Indexed: 06/10/2023]
Abstract
Formaldehyde poses significant threats to the ecosystem and is widely used as a toxicity indicator to obtain electrical signal feedback in electroactive biofilm (EAB)-based sensors. Although many optimizations have been adopted to improve the performance of EAB to formaldehyde, nearly no studies have discussed the toxicity of formaldehyde to EAB. Here, EABs were acclimated with a stable current density (8.9 ± 0.2 A/m2) and then injected with formaldehyde. The current density decreased by 27% and 98% after the injection of 1 and 10 ppm formaldehyde, respectively, compared with that in the control. The ecotoxicity of formaldehyde caused the irreversible loss of current with 3% (1 ppm) and 81% (10 ppm). Confocal laser scanning microscopy and scanning electron microscopy results showed that the redox activity was inhibited by formaldehyde, and the number of dead/broken cells increased from 2% to 40% (1 ppm) and 91% (10 ppm). The contents of the total protein and extracellular polymer substances decreased by more than 28% (1 ppm) and 75% (10 ppm) because of the cleavage reaction caused by formaldehyde. Bacterial community analysis showed that the proportion of Geobacter decreased from 81% to 53% (1 ppm) and 24% (10 ppm). As a result, the current production was significantly impaired, and the irreversible loss increased. Toxicological analysis demonstrated that formaldehyde disturbed the physiological indices of cells, thereby inducing apoptosis. These findings fill the gap of ecotoxicology of toxicants to EAB in a bioelectrochemical system.
Collapse
Affiliation(s)
- Tian Li
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin, 300350, China
| | - Fan Chen
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin, 300350, China
| | - Qixing Zhou
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin, 300350, China.
| | - Xin Wang
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin, 300350, China
| | - Chengmei Liao
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin, 300350, China
| | - Lean Zhou
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin, 300350, China
| | - Lili Wan
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin, 300350, China
| | - Jingkun An
- Tianjin Key Lab of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin University, No. 92 Weijin Road, Nankai District, Tianjin, 300072, China
| | - Yuxuan Wan
- MOE Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, No. 38 Tongyan Road, Jinnan District, Tianjin, 300350, China
| | - Nan Li
- Tianjin Key Lab of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin University, No. 92 Weijin Road, Nankai District, Tianjin, 300072, China
| |
Collapse
|
46
|
Wu Q, Jiao S, Ma M, Peng S. Microbial fuel cell system: a promising technology for pollutant removal and environmental remediation. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2020; 27:6749-6764. [PMID: 31956948 DOI: 10.1007/s11356-020-07745-0] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/09/2019] [Accepted: 01/14/2020] [Indexed: 05/20/2023]
Abstract
The microbial fuel cell (MFC) system is a promising environmental remediation technology due to its simple compact design, low cost, and renewable energy producing. MFCs can convert chemical energy from waste matters to electrical energy, which provides a sustainable and environmentally friendly solution for pollutant degradations. In this review, we attempt to gather research progress of MFC technology in pollutant removal and environmental remediation. The main configurations and pollutant removal mechanism by MFCs are introduced. The research progress of MFC systems in pollutant removal and environmental remediation, including wastewater treatment, soil remediation, natural water and groundwater remediation, sludge and solid waste treatment, and greenhouse gas emission control, as well as the application of MFCs in environmental monitoring have been reviewed. Subsequently, the application of MFCs in environmental monitoring and the combination of MFCs with other technologies are described. Finally, the current limitations and potential future research has been demonstrated in this review.
Collapse
Affiliation(s)
- Qing Wu
- School of Environmental Science and Engineering, Tianjin University, No. 135 Yaguan Road, Jinnan District, Tianjin, 300350, China.
| | - Shipu Jiao
- School of Environmental Science and Engineering, Tianjin University, No. 135 Yaguan Road, Jinnan District, Tianjin, 300350, China
| | - Mengxing Ma
- School of Environmental Science and Engineering, Tianjin University, No. 135 Yaguan Road, Jinnan District, Tianjin, 300350, China
| | - Sen Peng
- School of Environmental Science and Engineering, Tianjin University, No. 135 Yaguan Road, Jinnan District, Tianjin, 300350, China
| |
Collapse
|
47
|
Pan J, Hu J, Liu B, Li J, Wang D, Bu C, Wang X, Xiao K, Liang S, Yang J, Hou H. Enhanced quorum sensing of anode biofilm for better sensing linearity and recovery capability of microbial fuel cell toxicity sensor. ENVIRONMENTAL RESEARCH 2020; 181:108906. [PMID: 31740039 DOI: 10.1016/j.envres.2019.108906] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/11/2019] [Revised: 11/06/2019] [Accepted: 11/07/2019] [Indexed: 06/10/2023]
Abstract
MFC toxicity sensor has major hindrances that limit its practical application, such as the poor concentration-response relationship and inferior recovery capability after high toxicity shock. Till now, the direct influence of intrinsic properties on the performance of MFC toxicity sensor has not been well understood. Quorum sensing (QS) is a cell-to-cell communication strategy that indirectly affects the intrinsic properties of electroactive biofilms. In this work, commercially available QS autoinducers (AHLs) were applied to MFC toxicity sensor to manipulate anode biofilm for better sensing performance. The results showed that the addition of AHLs (C6-HSL, 3-OXO-C12-HSL) led to higher sensing linearity to a wider range of Pb2+. The voltage of MFC sensors with AHLs addition fully recovered even after 10 mg/L Cu2+ shock, indicating an enhanced recovery capability of MFC toxicity sensor. It was found that higher live/dead cells ratio and increased exoelectrogen Geobacter abundance were responsible for the superior sensing linearity and recovery capability of MFC toxicity sensor. Our work presented a novel and effective way to advance the process of MFC toxicity sensor application from the perspective of EABs.
Collapse
Affiliation(s)
- Jingyi Pan
- School of Environmental Science and Engineering, Huazhong University of Science and Technology (HUST), Wuhan, Hubei, 430074, PR China; Hubei Provincial Engineering Laboratory of Solid Waste Treatment, Disposal and Recycling, 1037 Luoyu Road, Wuhan, Hubei, 430074, China
| | - Jingping Hu
- School of Environmental Science and Engineering, Huazhong University of Science and Technology (HUST), Wuhan, Hubei, 430074, PR China; Hubei Provincial Engineering Laboratory of Solid Waste Treatment, Disposal and Recycling, 1037 Luoyu Road, Wuhan, Hubei, 430074, China; State Key Laboratory of Coal Combustion, Huazhong University of Science and Technology (HUST), 1037 Luoyu Road, Wuhan, Hubei, 430074, China
| | - Bingchuan Liu
- School of Environmental Science and Engineering, Huazhong University of Science and Technology (HUST), Wuhan, Hubei, 430074, PR China; Hubei Provincial Engineering Laboratory of Solid Waste Treatment, Disposal and Recycling, 1037 Luoyu Road, Wuhan, Hubei, 430074, China.
| | - Jianfeng Li
- School of Environmental Science and Engineering, Huazhong University of Science and Technology (HUST), Wuhan, Hubei, 430074, PR China; Hubei Provincial Engineering Laboratory of Solid Waste Treatment, Disposal and Recycling, 1037 Luoyu Road, Wuhan, Hubei, 430074, China
| | - Dongliang Wang
- School of Environmental Science and Engineering, Huazhong University of Science and Technology (HUST), Wuhan, Hubei, 430074, PR China; Hubei Provincial Engineering Laboratory of Solid Waste Treatment, Disposal and Recycling, 1037 Luoyu Road, Wuhan, Hubei, 430074, China
| | - Chenpeng Bu
- School of Environmental Science and Engineering, Huazhong University of Science and Technology (HUST), Wuhan, Hubei, 430074, PR China; Hubei Provincial Engineering Laboratory of Solid Waste Treatment, Disposal and Recycling, 1037 Luoyu Road, Wuhan, Hubei, 430074, China
| | - Xiaoxuan Wang
- School of Environmental Science and Engineering, Huazhong University of Science and Technology (HUST), Wuhan, Hubei, 430074, PR China; Hubei Provincial Engineering Laboratory of Solid Waste Treatment, Disposal and Recycling, 1037 Luoyu Road, Wuhan, Hubei, 430074, China
| | - Keke Xiao
- School of Environmental Science and Engineering, Huazhong University of Science and Technology (HUST), Wuhan, Hubei, 430074, PR China; Hubei Provincial Engineering Laboratory of Solid Waste Treatment, Disposal and Recycling, 1037 Luoyu Road, Wuhan, Hubei, 430074, China
| | - Sha Liang
- School of Environmental Science and Engineering, Huazhong University of Science and Technology (HUST), Wuhan, Hubei, 430074, PR China; Hubei Provincial Engineering Laboratory of Solid Waste Treatment, Disposal and Recycling, 1037 Luoyu Road, Wuhan, Hubei, 430074, China
| | - Jiakuan Yang
- School of Environmental Science and Engineering, Huazhong University of Science and Technology (HUST), Wuhan, Hubei, 430074, PR China; Hubei Provincial Engineering Laboratory of Solid Waste Treatment, Disposal and Recycling, 1037 Luoyu Road, Wuhan, Hubei, 430074, China; State Key Laboratory of Coal Combustion, Huazhong University of Science and Technology (HUST), 1037 Luoyu Road, Wuhan, Hubei, 430074, China
| | - Huijie Hou
- School of Environmental Science and Engineering, Huazhong University of Science and Technology (HUST), Wuhan, Hubei, 430074, PR China; Hubei Provincial Engineering Laboratory of Solid Waste Treatment, Disposal and Recycling, 1037 Luoyu Road, Wuhan, Hubei, 430074, China.
| |
Collapse
|
48
|
Jiang Y, Chu N, Qian DK, Jianxiong Zeng R. Microbial electrochemical stimulation of caproate production from ethanol and carbon dioxide. BIORESOURCE TECHNOLOGY 2020; 295:122266. [PMID: 31669871 DOI: 10.1016/j.biortech.2019.122266] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/02/2019] [Revised: 10/08/2019] [Accepted: 10/12/2019] [Indexed: 06/10/2023]
Abstract
The production of value added chemicals from CO2 is of critical importance for the practical application of microbial electrosynthesis (MES). Here, a binary electron donor (ED) design (using electrode and ethanol) was introduced to provide an efficient caproate production with the bioconversion of both CO2 and ethanol. A maximum caproate production rate of 2.41 ± 0.69 g L-1 d-1, and a final concentration of 7.66 ± 1.38 g L-1 was achieved. Caproate production selectivity based on the substrate increased to 91.47 ± 0.58% (Binary EDs) from 32.22 ± 32.58% (open circuit Electrode ED). An observed amount of 23.43 ± 0.69% of carbon within the final binary ED products originated from the CO2. This work proves for the first time the potential of caproate production from CO2 utilization and ethanol upgrading using solid electrodes to regulate the chain elongation process.
Collapse
Affiliation(s)
- Yong Jiang
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian 350002, China
| | - Na Chu
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian 350002, China
| | - Ding-Kang Qian
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian 350002, China
| | - Raymond Jianxiong Zeng
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian 350002, China.
| |
Collapse
|
49
|
Hao S, Sun X, Zhang H, Zhai J, Dong S. Recent development of biofuel cell based self-powered biosensors. J Mater Chem B 2020; 8:3393-3407. [DOI: 10.1039/c9tb02428j] [Citation(s) in RCA: 38] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
BFC-based SPBs have been used as power sources for other devices and as sensors for detecting toxicity and BOM.
Collapse
Affiliation(s)
- Shuai Hao
- State Key Laboratory of Electroanalytical Chemistry
- Changchun Institute of Applied Chemistry
- Chinese Academy of Sciences
- Changchun 130022
- China
| | - Xiaoxuan Sun
- State Key Laboratory of Electroanalytical Chemistry
- Changchun Institute of Applied Chemistry
- Chinese Academy of Sciences
- Changchun 130022
- China
| | - He Zhang
- State Key Laboratory of Electroanalytical Chemistry
- Changchun Institute of Applied Chemistry
- Chinese Academy of Sciences
- Changchun 130022
- China
| | - Junfeng Zhai
- State Key Laboratory of Electroanalytical Chemistry
- Changchun Institute of Applied Chemistry
- Chinese Academy of Sciences
- Changchun 130022
- China
| | - Shaojun Dong
- State Key Laboratory of Electroanalytical Chemistry
- Changchun Institute of Applied Chemistry
- Chinese Academy of Sciences
- Changchun 130022
- China
| |
Collapse
|
50
|
Cho JH, Gao Y, Choi S. A Portable, Single-Use, Paper-Based Microbial Fuel Cell Sensor for Rapid, On-Site Water Quality Monitoring. SENSORS 2019; 19:s19245452. [PMID: 31835692 PMCID: PMC6960574 DOI: 10.3390/s19245452] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/24/2019] [Revised: 12/01/2019] [Accepted: 12/09/2019] [Indexed: 12/26/2022]
Abstract
Human access to safe water has become a major problem in many parts of the world as increasing human activities continue to spill contaminants into our water systems. To guarantee the protection of the public as well as the environment, a rapid and sensitive way to detect contaminants is required. In this work, a paper-based microbial fuel cell was developed to act as a portable, single-use, on-site water quality sensor. The sensor was fabricated by combining two layers of paper for a simple, low-cost, and disposable design. To facilitate the use of the sensor for on-site applications, the bacterial cells were pre-inoculated onto the device by air-drying. To eliminate any variations, the voltage generated by the microorganism before and after the air-drying process was measured and calculated as an inhibition ratio. Upon the addition of different formaldehyde concentrations (0%, 0.001%, 0.005%, and 0.02%), the inhibition ratios obtained were 5.9 ± 0.7%, 6.9 ± 0.7%, 8.2 ± 0.6%, and 10.6 ± 0.2%, respectively. The inhibition ratio showed a good linearity with the formaldehyde concentrations at R2 = 0.931. Our new sensor holds great promise in monitoring water quality as a portable, low-cost, and on-site sensor.
Collapse
|