1
|
Rypar T, Bezdekova J, Pavelicova K, Vodova M, Adam V, Vaculovicova M, Macka M. Low-tech vs. high-tech approaches in μPADs as a result of contrasting needs and capabilities of developed and developing countries focusing on diagnostics and point-of-care testing. Talanta 2024; 266:124911. [PMID: 37536103 DOI: 10.1016/j.talanta.2023.124911] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2023] [Revised: 06/28/2023] [Accepted: 07/02/2023] [Indexed: 08/05/2023]
Abstract
Paper-based analysis has captivated scientists' attention in the field of analytical chemistry and related areas for the last two decades. Arguably no other area of modern chemical analysis is so broad and diverse in its approaches spanning from simple 'low-tech' low-cost paper-based analytical devices (PADs) requiring no or simple instrumentation, to sophisticated PADs and microfluidic paper-based analytical devices (μPADs) featuring elements of modern material science and nanomaterials affording high selectivity and sensitivity. Correspondingly diverse is the applicability, covering resource-limited scenarios on the one hand and most advanced approaches on the other. Herein we offer a view reflecting this diversity in the approaches and types of devices. The core idea of this article rests in dividing μPADs according to their type into two groups: A) instrumentation-free μPADs for resource-limited scenarios or developing countries and B) instrumentation-based μPADs as futuristic POC devices for e-diagnostics mainly aimed at developed countries. Each of those two groups is presented and discussed with the view of the main requirements in the given area, the most common targets, sample types and suitable detection approaches either implementing high-tech elements or low-tech low-cost approaches. Finally, a socioeconomic perspective is offered in discussing the fabrication and operational costs of μPADs, and, future perspectives are offered.
Collapse
Affiliation(s)
- Tomas Rypar
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, 613 00, Brno, Czech Republic
| | - Jaroslava Bezdekova
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, 613 00, Brno, Czech Republic
| | - Kristyna Pavelicova
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, 613 00, Brno, Czech Republic
| | - Milada Vodova
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, 613 00, Brno, Czech Republic
| | - Vojtech Adam
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, 613 00, Brno, Czech Republic
| | - Marketa Vaculovicova
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, 613 00, Brno, Czech Republic
| | - Mirek Macka
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, 613 00, Brno, Czech Republic; Central European Institute of Technology, Brno University of Technology, Purkynova 123, 612 00, Brno, Czech Republic; Australian Centre for Research on Separation Science and School o Natural Sciences, University of Tasmania, Private Bag 75, Hobart TAS, 7001, Australia.
| |
Collapse
|
2
|
Castelli FA, Rosati G, Moguet C, Fuentes C, Marrugo-Ramírez J, Lefebvre T, Volland H, Merkoçi A, Simon S, Fenaille F, Junot C. Metabolomics for personalized medicine: the input of analytical chemistry from biomarker discovery to point-of-care tests. Anal Bioanal Chem 2022; 414:759-789. [PMID: 34432105 PMCID: PMC8386160 DOI: 10.1007/s00216-021-03586-z] [Citation(s) in RCA: 34] [Impact Index Per Article: 17.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Revised: 07/24/2021] [Accepted: 07/27/2021] [Indexed: 12/30/2022]
Abstract
Metabolomics refers to the large-scale detection, quantification, and analysis of small molecules (metabolites) in biological media. Although metabolomics, alone or combined with other omics data, has already demonstrated its relevance for patient stratification in the frame of research projects and clinical studies, much remains to be done to move this approach to the clinical practice. This is especially true in the perspective of being applied to personalized/precision medicine, which aims at stratifying patients according to their risk of developing diseases, and tailoring medical treatments of patients according to individual characteristics in order to improve their efficacy and limit their toxicity. In this review article, we discuss the main challenges linked to analytical chemistry that need to be addressed to foster the implementation of metabolomics in the clinics and the use of the data produced by this approach in personalized medicine. First of all, there are already well-known issues related to untargeted metabolomics workflows at the levels of data production (lack of standardization), metabolite identification (small proportion of annotated features and identified metabolites), and data processing (from automatic detection of features to multi-omic data integration) that hamper the inter-operability and reusability of metabolomics data. Furthermore, the outputs of metabolomics workflows are complex molecular signatures of few tens of metabolites, often with small abundance variations, and obtained with expensive laboratory equipment. It is thus necessary to simplify these molecular signatures so that they can be produced and used in the field. This last point, which is still poorly addressed by the metabolomics community, may be crucial in a near future with the increased availability of molecular signatures of medical relevance and the increased societal demand for participatory medicine.
Collapse
Affiliation(s)
- Florence Anne Castelli
- Université Paris-Saclay, CEA, INRAE, Département Médicaments et Technologies pour la Santé (MTS), Gif-sur-Yvette cedex, 91191, France
- MetaboHUB, Gif-sur-Yvette, France
| | - Giulio Rosati
- Institut Català de Nanociència i Nanotecnologia (ICN2), Edifici ICN2 Campus UAB, 08193 Bellaterra, Barcelona, Spain
| | - Christian Moguet
- Université Paris-Saclay, CEA, INRAE, Département Médicaments et Technologies pour la Santé (MTS), Gif-sur-Yvette cedex, 91191, France
| | - Celia Fuentes
- Institut Català de Nanociència i Nanotecnologia (ICN2), Edifici ICN2 Campus UAB, 08193 Bellaterra, Barcelona, Spain
| | - Jose Marrugo-Ramírez
- Institut Català de Nanociència i Nanotecnologia (ICN2), Edifici ICN2 Campus UAB, 08193 Bellaterra, Barcelona, Spain
| | - Thibaud Lefebvre
- Université Paris-Saclay, CEA, INRAE, Département Médicaments et Technologies pour la Santé (MTS), Gif-sur-Yvette cedex, 91191, France
- Centre de Recherche sur l'Inflammation/CRI, Université de Paris, Inserm, Paris, France
- CRMR Porphyrie, Hôpital Louis Mourier, AP-HP Nord - Université de Paris, Colombes, France
| | - Hervé Volland
- Université Paris-Saclay, CEA, INRAE, Département Médicaments et Technologies pour la Santé (MTS), Gif-sur-Yvette cedex, 91191, France
| | - Arben Merkoçi
- Institut Català de Nanociència i Nanotecnologia (ICN2), Edifici ICN2 Campus UAB, 08193 Bellaterra, Barcelona, Spain
| | - Stéphanie Simon
- Université Paris-Saclay, CEA, INRAE, Département Médicaments et Technologies pour la Santé (MTS), Gif-sur-Yvette cedex, 91191, France
| | - François Fenaille
- Université Paris-Saclay, CEA, INRAE, Département Médicaments et Technologies pour la Santé (MTS), Gif-sur-Yvette cedex, 91191, France
- MetaboHUB, Gif-sur-Yvette, France
| | - Christophe Junot
- Université Paris-Saclay, CEA, INRAE, Département Médicaments et Technologies pour la Santé (MTS), Gif-sur-Yvette cedex, 91191, France.
- MetaboHUB, Gif-sur-Yvette, France.
| |
Collapse
|
3
|
Simple, fast, and instrumentless fabrication of paper analytical devices by novel contact stamping method based on acrylic varnish and 3D printing. Mikrochim Acta 2021; 188:437. [PMID: 34837526 DOI: 10.1007/s00604-021-05102-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2021] [Accepted: 11/11/2021] [Indexed: 12/27/2022]
Abstract
A new contact stamping method for fabrication of paper-based analytical devices (PADs) is reported. It uses an all-purpose acrylic varnish and 3D-printed stamps to pattern hydrophobic structures on paper substrates. The use of 3D printing allows quickly prototyping the desired stamp shape without resorting to third-party services, which are often expensive and time consuming. To the best of our knowledge, this is the first report regarding the use of this material for creation of hydrophobic barriers in paper substrates, as well as this 3D printing-based stamping method. The acrylic varnish was characterized and the features of the stamping method were studied. The PADs developed here presented better compatibility with organic solvents and surfactants compared with similar protocols. Furthermore, the use of this contact stamping method for fabrication of paper electrochemical devices was also possible, as well as multiplexed microfluidic devices for lateral flow testing. The analytical applicability of the varnish-based PADs was demonstrated through the image-based colorimetric quantification of iron in pharmaceutical samples. A limit of detection of 0.61 mg L-1 was achieved. The results were compared with spectrophotometry for validation and presented great concordance (relative error was < 5% and recoveries were between 104 and 108%). Thus, taking into account the performance of the devices explored here, we believe this novel contact stamping method is a very interesting alternative for production of PADs, exhibiting great potentiality. In addition, this work brings a new application of 3D printing in analytical sciences.
Collapse
|
4
|
Singhal HR, Prabhu A, Giri Nandagopal M, Dheivasigamani T, Mani NK. One-dollar microfluidic paper-based analytical devices: Do-It-Yourself approaches. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106126] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
5
|
Mathaweesansurn A, Thongrod S, Khongkaew P, Phechkrajang CM, Wilairat P, Choengchan N. Simple and fast fabrication of microfluidic paper-based analytical device by contact stamping for multiple-point standard addition assay: Application to direct analysis of urinary creatinine. Talanta 2020; 210:120675. [DOI: 10.1016/j.talanta.2019.120675] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2019] [Revised: 12/21/2019] [Accepted: 12/23/2019] [Indexed: 02/06/2023]
|
6
|
Chen Y, Zhang L, Huang J, Deng Z, Yuan Y, Zou J, Nie J, Zhang Y. Enhanced functional DNA biosensor for distance-based read-by-eye quantification of various analytes based on starch-hydrolysis-adjusted wettability change in paper devices. RSC Adv 2020; 10:28121-28127. [PMID: 35519114 PMCID: PMC9055663 DOI: 10.1039/d0ra04619a] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2020] [Accepted: 07/19/2020] [Indexed: 12/26/2022] Open
Abstract
Low-cost, equipment-free and quantitative detection of a wide range of analytes of interest at home and in the field holds the potential to revolutionize disease diagnosis, environmental pollution monitoring, and food safety analysis. Herein, we describe a functional DNA biosensor for the first time that integrates analyte-directed assembly of enzyme-coated microbead probes for robust yet efficient signal amplification with a simple quantitative detection motif of distance measurement on portable paper devices based on starch-hydrolysis-adjusted wettability change of paper. Its utility is well demonstrated with highly sensitive and specific detection of model analytes ranging from adenosine (an important small biomolecule; 1.6 μM detection limit) to interferon-γ (a protein marker; 0.3 nM detection limit) and Pb2+ (a highly toxic metal ion; 0.5 nM detection limit) by simply using an inexpensive, ubiquitous ruler. The developed general method with the distance-measuring readout should be easily tailored for the portable, read-by-eye, quantitative detection of many other types of analytical targets by taking advantage of their specific functional DNA partners like aptamers and DNAzymes. A functional DNA sensor was initially developed for the distance-measuring quantification of various analytes based on the starch-hydrolysis-adjusted wettability change of paper.![]()
Collapse
Affiliation(s)
- Yijing Chen
- College of Chemistry and Bioengineering
- Guilin University of Technology
- Guilin 541004
- P. R. China
| | - Lang Zhang
- College of Chemistry and Bioengineering
- Guilin University of Technology
- Guilin 541004
- P. R. China
| | - Jinkun Huang
- College of Chemistry and Bioengineering
- Guilin University of Technology
- Guilin 541004
- P. R. China
| | - Zihao Deng
- College of Chemistry and Bioengineering
- Guilin University of Technology
- Guilin 541004
- P. R. China
| | - Yali Yuan
- College of Chemistry and Bioengineering
- Guilin University of Technology
- Guilin 541004
- P. R. China
| | - Jianmei Zou
- College of Chemistry and Bioengineering
- Guilin University of Technology
- Guilin 541004
- P. R. China
| | - Jinfang Nie
- College of Chemistry and Bioengineering
- Guilin University of Technology
- Guilin 541004
- P. R. China
| | - Yun Zhang
- College of Chemistry and Bioengineering
- Guilin University of Technology
- Guilin 541004
- P. R. China
| |
Collapse
|
7
|
Qi L, Zhang A, Wang Y, Liu L, Wang X. Atom transfer radical polymer-modified paper for improvement in protein fixation in paper-based ELISA. BMC Chem 2019; 13:110. [PMID: 31463479 PMCID: PMC6706939 DOI: 10.1186/s13065-019-0622-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2019] [Accepted: 07/31/2019] [Indexed: 12/21/2022] Open
Abstract
A newly modified paper-based enzyme-linked immunosorbent assay (P-ELISA) was established by immobilizing more proteins on the paper surface through an atom transfer radical polymerization (ATRP) reaction. In addition, introducing graphene oxide (GO) sheets, Au nanoparticles (AuNps) and two primary antibodies (Ab1s) led to signal amplification and cost reduction.
Collapse
Affiliation(s)
- Lu Qi
- 1Phase I Clinical Trial Center, Beijing Shijitan Hospital, Capital Medical University, Beijing, 100038 China
| | - Aihong Zhang
- Institute of Chemical Defense, Beijing, 102205 China
| | - Yu Wang
- 1Phase I Clinical Trial Center, Beijing Shijitan Hospital, Capital Medical University, Beijing, 100038 China
| | - Long Liu
- 1Phase I Clinical Trial Center, Beijing Shijitan Hospital, Capital Medical University, Beijing, 100038 China
| | - Xinghe Wang
- 1Phase I Clinical Trial Center, Beijing Shijitan Hospital, Capital Medical University, Beijing, 100038 China
| |
Collapse
|
8
|
Tian R, Li Y, Bai J. Hierarchical assembled nanomaterial paper based analytical devices for simultaneously electrochemical detection of microRNAs. Anal Chim Acta 2019; 1058:89-96. [DOI: 10.1016/j.aca.2019.01.036] [Citation(s) in RCA: 38] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2018] [Revised: 12/28/2018] [Accepted: 01/24/2019] [Indexed: 12/17/2022]
|
9
|
Fraser LA, Cheung YW, Kinghorn AB, Guo W, Shiu SCC, Jinata C, Liu M, Bhuyan S, Nan L, Shum HC, Tanner JA. Microfluidic Technology for Nucleic Acid Aptamer Evolution and Application. ACTA ACUST UNITED AC 2019; 3:e1900012. [PMID: 32627415 DOI: 10.1002/adbi.201900012] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2019] [Revised: 03/12/2019] [Indexed: 12/18/2022]
Abstract
The intersection of microfluidics and aptamer technologies holds particular promise for rapid progress in a plethora of applications across biomedical science and other areas. Here, the influence of microfluidics on the field of aptamers, from traditional capillary electrophoresis approaches through innovative modern-day approaches using micromagnetic beads and emulsion droplets, is reviewed. Miniaturizing aptamer-based bioassays through microfluidics has the potential to transform diagnostics and embedded biosensing in the coming years.
Collapse
Affiliation(s)
- Lewis A Fraser
- School of Biomedical Sciences, LKS Faculty of Medicine, The University of Hong Kong, Hong Kong (SAR), China
| | - Yee-Wai Cheung
- School of Biomedical Sciences, LKS Faculty of Medicine, The University of Hong Kong, Hong Kong (SAR), China
| | - Andrew B Kinghorn
- School of Biomedical Sciences, LKS Faculty of Medicine, The University of Hong Kong, Hong Kong (SAR), China
| | - Wei Guo
- Department of Mechanical Engineering, Faculty of Engineering, The University of Hong Kong, Hong Kong (SAR), China
| | - Simon Chi-Chin Shiu
- School of Biomedical Sciences, LKS Faculty of Medicine, The University of Hong Kong, Hong Kong (SAR), China
| | - Chandra Jinata
- School of Biomedical Sciences, LKS Faculty of Medicine, The University of Hong Kong, Hong Kong (SAR), China
| | - Mengping Liu
- School of Biomedical Sciences, LKS Faculty of Medicine, The University of Hong Kong, Hong Kong (SAR), China
| | - Soubhagya Bhuyan
- School of Biomedical Sciences, LKS Faculty of Medicine, The University of Hong Kong, Hong Kong (SAR), China
| | - Lang Nan
- Department of Mechanical Engineering, Faculty of Engineering, The University of Hong Kong, Hong Kong (SAR), China
| | - Ho Cheung Shum
- Department of Mechanical Engineering, Faculty of Engineering, The University of Hong Kong, Hong Kong (SAR), China
| | - Julian A Tanner
- School of Biomedical Sciences, LKS Faculty of Medicine, The University of Hong Kong, Hong Kong (SAR), China
| |
Collapse
|
10
|
Kong FZ, Jahan S, Zhong R, Cao XY, Li WL, Wang YX, Xiao H, Liu WW, Cao CX. Electrophoresis Titration Model of a Moving Redox Boundary Chip for a Point-of-Care Test of an Enzyme-Linked Immunosorbent Assay. ACS Sens 2019; 4:126-133. [PMID: 30604605 DOI: 10.1021/acssensors.8b01017] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Enzyme-linked immunosorbent assays (ELISAs) have been widely used in clinical examination, food safety, and environmental analyses. However, they still face a great challenge in designing a device for a point-of-care test (POCT) due to its bulk optical detector and complexity. Herein an electrophoresis titration (ET) model of a moving redox boundary (MRB) was proposed for constructing an ET-ELISA chip of a POCT just with sextuplet electrode pairs and laminated cells. The chip had an anodic well, middle well, and cathode well which were connected by microchannels. The ELISA process was conducted in the bottom of the middle well, where horseradish peroxidase (HRP) catalyzed 3,3',5,5'-tetra-methyl benzidine (TMB) as a blue TMB dimer with two positive charges. Under an electrical field of 29 V, the TMB dimer migrated into the titration channel and reacted with the ascorbic acid, creating an MRB. The MRB motion was a function of antigen content, indicating a visual distance-based assay. As a proof of concept, a C-reactive protein was chosen as a model antigen. The experiments systemically validated the ET-ELISA model and method. Particularly, the chip was smartphone-detected, traditional power supply free, and did not use sulfuric acid used in typical ELISA, making the ET-ELISA method extremely simple, portable, and safe. The ET-ELISA has great potential to visual and portable ELISA in clinical medicine, the environment, and food safety immunoassay.
Collapse
|
11
|
Zhang Y, Zhang L, Cui K, Ge S, Cheng X, Yan M, Yu J, Liu H. Flexible Electronics Based on Micro/Nanostructured Paper. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2018; 30:e1801588. [PMID: 30066444 DOI: 10.1002/adma.201801588] [Citation(s) in RCA: 107] [Impact Index Per Article: 17.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2018] [Revised: 05/02/2018] [Indexed: 05/26/2023]
Abstract
Over the past several years, a new surge of interest in paper electronics has arisen due to the numerous merits of simple micro/nanostructured substrates. Herein, the latest advances and principal issues in the design and fabrication of paper-based flexible electronics are highlighted. Following an introduction of the fascinating properties of paper matrixes, the construction of paper substrates from diverse functional materials for flexible electronics and their underlying principles are described. Then, notable progress related to the development of versatile electronic devices is discussed. Finally, future opportunities and the remaining challenges are examined. It is envisioned that more design concepts, working principles, and advanced papermaking techniques will be developed in the near future for the advanced functionalization of paper, paving the way for the mass production and commercial applications of flexible paper-based electronic devices.
Collapse
Affiliation(s)
- Yan Zhang
- Institute for Advanced Interdisciplinary Research, University of Jinan, Jinan, 250022, China
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, China
| | - Lina Zhang
- Shandong Provincial Key Laboratory of Preparation and Measurement of Building Materials, University of Jinan, Jinan, 250022, China
| | - Kang Cui
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, China
| | - Shenguang Ge
- Institute for Advanced Interdisciplinary Research, University of Jinan, Jinan, 250022, China
| | - Xin Cheng
- Shandong Provincial Key Laboratory of Preparation and Measurement of Building Materials, University of Jinan, Jinan, 250022, China
| | - Mei Yan
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, China
| | - Jinghua Yu
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, China
| | - Hong Liu
- Institute for Advanced Interdisciplinary Research, University of Jinan, Jinan, 250022, China
| |
Collapse
|
12
|
de Oliveira TR, Fonseca WT, de Oliveira Setti G, Faria RC. Fast and flexible strategy to produce electrochemical paper-based analytical devices using a craft cutter printer to create wax barrier and screen-printed electrodes. Talanta 2018; 195:480-489. [PMID: 30625573 DOI: 10.1016/j.talanta.2018.11.047] [Citation(s) in RCA: 58] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2018] [Revised: 11/13/2018] [Accepted: 11/15/2018] [Indexed: 11/17/2022]
Abstract
This paper describes a simple, low-cost, and highly flexible rapid prototyping method to construct electrochemical paper-based analytical device (ePAD) for multiplexed analyte determinations. The ePAD was composed of two electrochemical cell (EC) compartments, separated by hydrophobic barriers of wax, and screen-printed electrodes (SPEs) deposited directly over the surface of the filter paper. The ePAD was entirely constructed using an inexpensive craft cutter printer with no needed of a wax printer. The rapid prototyping method involves two steps: the deposition of the SPEs and the creation of the wax barriers. In this case, the SPEs were screen-printed on filter paper by using adhesive tape as mask by cutting the electrodes pattern with the cutter printer. Following, the wax barriers were created using stamps made of filter paper also cut with the printer and impregnated with wax. In the ePAD, each ECs containing an array of 4-working electrodes, allowing up to 4 replicates in a single measurement. Both ECs shared one counter and one reference electrodes, permitting the simultaneous multianalysis. The ePAD was successfully applied to simultaneous detection of paracetamol (PAR), caffeine (CAF), and ascorbic acid (AA) in drugs. PAR and CAF were detected in a sample using one EC and AA was detected, in a different sample, on the other EC, both with no chemical modifications in the working electrodes. Limits of detection of 0.04 mmol L-1 for PAR, 0.22 mmol L-1 for CAF, and 0.40 mmol L-1 for AA were obtained. The construction process proposed provide an easy way to implement screen-printing electrodes and wax barriers in filter paper to create electrochemical devices for fast and simultaneous multianalysis.
Collapse
Affiliation(s)
- Tássia Regina de Oliveira
- Department of Chemistry, Federal University of São Carlos, Rod. Washington Luís km 235 - SP-310, São Carlos, SP 13565-905, Brazil.
| | - Wilson Tiago Fonseca
- Department of Chemistry, Federal University of São Carlos, Rod. Washington Luís km 235 - SP-310, São Carlos, SP 13565-905, Brazil.
| | - Grazielle de Oliveira Setti
- Department of Chemistry, Federal University of São Carlos, Rod. Washington Luís km 235 - SP-310, São Carlos, SP 13565-905, Brazil.
| | - Ronaldo Censi Faria
- Department of Chemistry, Federal University of São Carlos, Rod. Washington Luís km 235 - SP-310, São Carlos, SP 13565-905, Brazil.
| |
Collapse
|
13
|
Mazaafrianto DN, Maeki M, Ishida A, Tani H, Tokeshi M. Recent Microdevice-Based Aptamer Sensors. MICROMACHINES 2018; 9:E202. [PMID: 30424135 PMCID: PMC6187364 DOI: 10.3390/mi9050202] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/07/2018] [Revised: 04/19/2018] [Accepted: 04/21/2018] [Indexed: 12/17/2022]
Abstract
Since the systematic evolution of ligands by exponential enrichment (SELEX) method was developed, aptamers have made significant contributions as bio-recognition sensors. Microdevice systems allow for low reagent consumption, high-throughput of samples, and disposability. Due to these advantages, there has been an increasing demand to develop microfluidic-based aptasensors for analytical technique applications. This review introduces the principal concepts of aptasensors and then presents some advanced applications of microdevice-based aptasensors on several platforms. Highly sensitive detection techniques, such as electrochemical and optical detection, have been integrated into lab-on-a-chip devices and researchers have moved towards the goal of establishing point-of-care diagnoses for target analyses.
Collapse
Affiliation(s)
- Donny Nugraha Mazaafrianto
- Graduate School of Chemical Sciences and Engineering, Hokkaido University, Kita 13 Nishi 8, Kita-ku, Sapporo 060-8628, Japan.
| | - Masatoshi Maeki
- Division of Applied Chemistry, Faculty of Engineering, Hokkaido University, Kita 13 Nishi 8, Kita-ku, Sapporo 060-8628, Japan.
| | - Akihiko Ishida
- Division of Applied Chemistry, Faculty of Engineering, Hokkaido University, Kita 13 Nishi 8, Kita-ku, Sapporo 060-8628, Japan.
| | - Hirofumi Tani
- Division of Applied Chemistry, Faculty of Engineering, Hokkaido University, Kita 13 Nishi 8, Kita-ku, Sapporo 060-8628, Japan.
| | - Manabu Tokeshi
- Division of Applied Chemistry, Faculty of Engineering, Hokkaido University, Kita 13 Nishi 8, Kita-ku, Sapporo 060-8628, Japan.
- ImPACT Research Center for Advanced Nanobiodevices, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603, Japan.
- Innovative Research Center for Preventive Medical Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8601, Japan.
- Institute of Innovation for Future Society, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8601, Japan.
| |
Collapse
|
14
|
Abstract
Nucleic acid aptamers have tremendous potential as molecular recognition elements in biomedical targeting, analytical arrays, and self-signaling sensors. However, practical limitations and inefficiencies in the process of selecting novel aptamers (SELEX) have hampered widespread adoption of aptamer technologies. Many factors have recently contributed to more effective aptamer screening, but no influence has done more to increase the efficiency, scale, and automation of aptamer selection than that of new microfluidic SELEX techniques. This review introduces aptamers as a powerful chemical and biological tool, briefly highlights traditional SELEX techniques and their limitations, covers in detail the recent advancements in microfluidic methods of aptamer selection and characterization, and suggests possible future directions of the field.
Collapse
Affiliation(s)
- Sean K Dembowski
- Department of Chemistry, University of Minnesota, Minneapolis, MN 55455, USA.
| | | |
Collapse
|
15
|
Lin B, Yu Y, Cao Y, Guo M, Zhu D, Dai J, Zheng M. Point-of-care testing for streptomycin based on aptamer recognizing and digital image colorimetry by smartphone. Biosens Bioelectron 2017; 100:482-489. [PMID: 28965053 DOI: 10.1016/j.bios.2017.09.028] [Citation(s) in RCA: 77] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2017] [Revised: 09/14/2017] [Accepted: 09/17/2017] [Indexed: 01/04/2023]
Abstract
The rapid detection of antibiotic residual in everyday life is very important for food safety. In order to realize the on-site and visual detection of antibiotic, a POCT method was established by using digital image colorimetry based on smartphone. Streptomycin was taken as the analyte model of antibiotics, streptomycin aptamer preferentially recognized analyte, and the excess aptamer hybridized with the complementary DNA to form the dsDNA. SYBR Green I combined with the dsDNA and then emitted obvious green fluorescence, thus the fluorescence intensity decreased with the increasing of streptomycin concentration. Then a smartphone-based device was constructed as the fluorescence readout. The smartphone camera acquired the images of the fluorescence derived from the samples, and the Touch Color APP installed in smartphone read out the RGB values of the images. There was a linear relationship between the G values and the streptomycin concentrations in the range of 0.1-100µM. The detection limit was 94nM, which was lower than the maximum residue limit defined by World Health Organization. The POCT method was applied for determining streptomycin in chicken and milk samples with recoveries in 94.1-110%. This method had the advantages of good selectivity, simple operation and on-site visualization.
Collapse
Affiliation(s)
- Bixia Lin
- School of Chemistry and Environment, Guangzhou Key Laboratory of Analytical Chemistry for Biomedicine, South China Normal University, Guangzhou, China
| | - Ying Yu
- School of Chemistry and Environment, Guangzhou Key Laboratory of Analytical Chemistry for Biomedicine, South China Normal University, Guangzhou, China.
| | - Yujuan Cao
- School of Chemistry and Environment, Guangzhou Key Laboratory of Analytical Chemistry for Biomedicine, South China Normal University, Guangzhou, China
| | - Manli Guo
- School of Chemistry and Environment, Guangzhou Key Laboratory of Analytical Chemistry for Biomedicine, South China Normal University, Guangzhou, China
| | - Debin Zhu
- School of Chemistry and Environment, Guangzhou Key Laboratory of Analytical Chemistry for Biomedicine, South China Normal University, Guangzhou, China
| | - Jiaxing Dai
- School of Chemistry and Environment, Guangzhou Key Laboratory of Analytical Chemistry for Biomedicine, South China Normal University, Guangzhou, China
| | - Minshi Zheng
- School of Chemistry and Environment, Guangzhou Key Laboratory of Analytical Chemistry for Biomedicine, South China Normal University, Guangzhou, China
| |
Collapse
|