1
|
Li S, Zhang H, Zhu M, Kuang Z, Li X, Xu F, Miao S, Zhang Z, Lou X, Li H, Xia F. Electrochemical Biosensors for Whole Blood Analysis: Recent Progress, Challenges, and Future Perspectives. Chem Rev 2023. [PMID: 37262362 DOI: 10.1021/acs.chemrev.1c00759] [Citation(s) in RCA: 42] [Impact Index Per Article: 21.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Whole blood, as one of the most significant biological fluids, provides critical information for health management and disease monitoring. Over the past 10 years, advances in nanotechnology, microfluidics, and biomarker research have spurred the development of powerful miniaturized diagnostic systems for whole blood testing toward the goal of disease monitoring and treatment. Among the techniques employed for whole-blood diagnostics, electrochemical biosensors, as known to be rapid, sensitive, capable of miniaturization, reagentless and washing free, become a class of emerging technology to achieve the target detection specifically and directly in complex media, e.g., whole blood or even in the living body. Here we are aiming to provide a comprehensive review to summarize advances over the past decade in the development of electrochemical sensors for whole blood analysis. Further, we address the remaining challenges and opportunities to integrate electrochemical sensing platforms.
Collapse
Affiliation(s)
- Shaoguang Li
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Hongyuan Zhang
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Man Zhu
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Zhujun Kuang
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Xun Li
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Fan Xu
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Siyuan Miao
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Zishuo Zhang
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Xiaoding Lou
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Hui Li
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Fan Xia
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| |
Collapse
|
2
|
Li C, Che B, Deng L. Electrochemical Biosensors Based on Carbon Nanomaterials for Diagnosis of Human Respiratory Diseases. BIOSENSORS 2022; 13:12. [PMID: 36671847 PMCID: PMC9855565 DOI: 10.3390/bios13010012] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Revised: 12/13/2022] [Accepted: 12/21/2022] [Indexed: 06/17/2023]
Abstract
In recent years, respiratory diseases have increasingly become a global concern, largely due to the outbreak of Coronavirus Disease 2019 (COVID-19). This inevitably causes great attention to be given to the development of highly efficient and minimal or non-invasive methods for the diagnosis of respiratory diseases. And electrochemical biosensors based on carbon nanomaterials show great potential in fulfilling the requirement, not only because of the superior performance of electrochemical analysis, but also given the excellent properties of the carbon nanomaterials. In this paper, we review the most recent advances in research, development and applications of electrochemical biosensors based on the use of carbon nanomaterials for diagnosis of human respiratory diseases in the last 10 years. We first briefly introduce the characteristics of several common human respiratory diseases, including influenza, COVID-19, pulmonary fibrosis, tuberculosis and lung cancer. Then, we describe the working principles and fabrication of various electrochemical biosensors based on carbon nanomaterials used for diagnosis of these respiratory diseases. Finally, we summarize the advantages, challenges, and future perspectives for the currently available electrochemical biosensors based on carbon nanomaterials for detecting human respiratory diseases.
Collapse
|
3
|
Eissa S, Al-Kattan K, Zourob M. Combination of Carbon Nanofiber-Based Electrochemical Biosensor and Cotton Fiber: A Device for the Detection of the Middle-East Respiratory Syndrome Coronavirus. ACS OMEGA 2021; 6:32072-32080. [PMID: 34870028 PMCID: PMC8638009 DOI: 10.1021/acsomega.1c04849] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Accepted: 10/15/2021] [Indexed: 05/28/2023]
Abstract
The miniaturization of biosensors for point-of-care diagnosis is highly important in infection control. Electrochemical biosensors offer several advantages in diagnosis in terms of cost, disposability, portability, and sensitivity. Here, a miniaturized electrochemical immunosensor combined with cotton fiber for the detection of the Middle-East respiratory syndrome coronavirus (MERS-CoV) is described. Taking advantage of the absorption capability of cotton, the nasal and saliva samples can be collected and directly transferred to the immunosensor surface for detection using a single tool. The immunosensor was fabricated on a disposable screen-printed electrode precoated with carbon nanofibers. The electrodes were functionalized with carboxyphenyl groups that were used for the immobilization of the spike protein of the MERS-CoV. A competitive detection scheme was employed using the antibody for the MERS-CoV spike protein, and the square-wave voltammetry technique was used for measurements. The biosensor tested after the cotton coating of the electrode exhibited excellent performance. The biosensor was capable of detecting the MERS-CoV spike protein within a concentration range from 0.1 pg·mL-1 to 1 μg·mL-1 with a limit of detection of 0.07 pg·mL, implying the high sensitivity of the method. The immunosensor did not exhibit any cross-reactivity against proteins from HCoV and Influenza A, indicating the excellent selectivity of this approach. Testing of the biosensor in nasal samples showed very high recovery percentages. This disposable biosensor can be used as a miniaturized device for the collection of samples and detection of the virus using a portable potentiostat connected to a smartphone.
Collapse
Affiliation(s)
- Shimaa Eissa
- Department
of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, Al
Takhassusi Road, Riyadh 11533, Saudi Arabia
| | - Khaled Al-Kattan
- Department
of Microbiology and Immunology, College of Medicine, Alfaisal University, Al Zahrawi Street, Al Maather, Al Takhassusi Road, Riyadh 11533, Saudi Arabia
| | - Mohammed Zourob
- Department
of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, Al
Takhassusi Road, Riyadh 11533, Saudi Arabia
| |
Collapse
|
4
|
Bai YY, Yang YJ, Wu Z, Yang XY, Lin M, Pang DW, Zhang ZL. Size-Resolved Single Entity Collision Biosensing for Dual Quantification of MicroRNAs in a Single Run. ACS APPLIED MATERIALS & INTERFACES 2021; 13:22254-22261. [PMID: 33966389 DOI: 10.1021/acsami.1c04747] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Limited to the accuracy of size resolution, single entity collision biosensing (SECBS) for multiplex immunoassays remains challenging, because it is difficult to get the true value of nanoparticle (NP) sizes based on the current intensity due to the complex movement of NPs on the electrode surface. Considering that the size-dependent movement of NPs meanwhile will generate a characteristic current shape, in this work, the huge difference in the current rise time of 5 and 15 nm Pt NPs colliding on an Au ultramicroelectrode (d = 30 μm) was originally used to develop a size-resolved SECBS for multiplex immunoassays of miRNAs. The limit concentration that can be detected was 0.5 fM. Compared with conventional electrochemical biosensors for multiplex immunoassays, for the size-resolved SECBS, one does not need to worry about potential overlapping. Therefore, the proposed method demonstrates a promising potential for the application of SECBS in multiplex immunoassays.
Collapse
Affiliation(s)
- Yi-Yan Bai
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, People's Republic of China
| | - Yan-Ju Yang
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, People's Republic of China
| | - Zhen Wu
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, People's Republic of China
| | - Xiao-Yan Yang
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, People's Republic of China
| | - Miao Lin
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, People's Republic of China
| | - Dai-Wen Pang
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, People's Republic of China
| | - Zhi-Ling Zhang
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, People's Republic of China
| |
Collapse
|
5
|
Norouzi P, Nezamoddini M, Safarnejad MR. Antibody-oriented immobilization for newcastle disease virus detection using label free electrochemical immunosensor. CHEMICAL PAPERS 2021. [DOI: 10.1007/s11696-021-01546-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
6
|
Abdulkarim H, Zourob M, Siaj M. Development of Label-Free Impedimetric Immunosensors for IKZF1 and IKZF3 Femtomolar Detection for Monitoring Multiple Myeloma Patients Treated with Lenalidomide. Sci Rep 2020; 10:10424. [PMID: 32591583 PMCID: PMC7320141 DOI: 10.1038/s41598-020-67241-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2019] [Accepted: 06/02/2020] [Indexed: 11/09/2022] Open
Abstract
Lenalidomide is an immunomodulatory drug (IMiD) used to treat multiple myeloma (MM) patients. Lenalidomide destroys MM cells by inducing ubiquitination and the consequent degradation of Ikaros family zinc finger proteins 1 and 3 (IKZF1 and IKZF3). High expression of IKZF1 and IKZF3 in MM results in less sensitivity to lenalidomide treatment and possible cytotoxic effect. Therefore, detecting the expression of IKZF1 and IKZF3 proteins is of utmost importance in the treatment of MM. Here, we report the fabrication of a novel label-free electrochemical immunosensor for the rapid detection and quantification of IKZF1 and IKZF3 using electrochemical impedance spectroscopy (EIS). Gold electrodes were used to fabricate the immunosensors by immobilizing IKZF1 and IKZF3 specific antibodies using cysteamine and PDITC crosslinkers. The immunosensors were able to detect IKZF1 and IKZF3 protein levels with respective low detection limits of 0.68 and 0.97 pg/ml (11.8 and 16.7 fM). Furthermore, the immunosensors’ successful application in human serum and their high selectivity and sensitivity enables their possible application in other biofluids as simple point-of-care devices for monitoring multiple myeloma patients treated with lenalidomide, to prevent the drug’s cytotoxicity and minimize its side effects.
Collapse
Affiliation(s)
- Haya Abdulkarim
- Department of Chemistry, Université du Québec à Montréal, Montréal, H3C 3P8, Quebec, Canada
| | - Mohammed Zourob
- Department of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, Al Takhassusi Road, Riyadh, 11533, Saudi Arabia.,King Faisal Specialist Hospital and Research Center, Zahrawi Street, Al Maather, Riyadh, 12713, Saudi Arabia
| | - Mohamed Siaj
- Department of Chemistry, Université du Québec à Montréal, Montréal, H3C 3P8, Quebec, Canada.
| |
Collapse
|
7
|
Jones A, Dhanapala L, Kankanamage RNT, Kumar CV, Rusling JF. Multiplexed Immunosensors and Immunoarrays. Anal Chem 2020; 92:345-362. [PMID: 31726821 PMCID: PMC7202053 DOI: 10.1021/acs.analchem.9b05080] [Citation(s) in RCA: 91] [Impact Index Per Article: 18.2] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Affiliation(s)
- Abby Jones
- Department of Chemistry, University of Connecticut, 55 North Eagleville Road, Storrs, Connecticut 06269, United States
| | - Lasangi Dhanapala
- Department of Chemistry, University of Connecticut, 55 North Eagleville Road, Storrs, Connecticut 06269, United States
| | - Rumasha N. T. Kankanamage
- Department of Chemistry, University of Connecticut, 55 North Eagleville Road, Storrs, Connecticut 06269, United States
| | - Challa V. Kumar
- Department of Chemistry, University of Connecticut, 55 North Eagleville Road, Storrs, Connecticut 06269, United States
- Institute of Materials Science, University of Connecticut, 97 North Eagleville Road, Storrs, Connecticut 06269, United States
| | - James F. Rusling
- Department of Chemistry, University of Connecticut, 55 North Eagleville Road, Storrs, Connecticut 06269, United States
- Institute of Materials Science, University of Connecticut, 97 North Eagleville Road, Storrs, Connecticut 06269, United States
- Department of Surgery and Neag Cancer Center, University of Connecticut Health Center, Farmington, Connecticut 06232, United States
- School of Chemistry, National University of Ireland Galway, University Road, Galway, Ireland H91 TK33
| |
Collapse
|
8
|
Wang Z, Wu S, Wang J, Yu A, Wei G. Carbon Nanofiber-Based Functional Nanomaterials for Sensor Applications. NANOMATERIALS 2019; 9:nano9071045. [PMID: 31336563 PMCID: PMC6669495 DOI: 10.3390/nano9071045] [Citation(s) in RCA: 70] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/02/2019] [Revised: 07/19/2019] [Accepted: 07/19/2019] [Indexed: 02/07/2023]
Abstract
Carbon nanofibers (CNFs) exhibit great potentials in the fields of materials science, biomedicine, tissue engineering, catalysis, energy, environmental science, and analytical science due to their unique physical and chemical properties. Usually, CNFs with flat, mesoporous, and porous surfaces can be synthesized by chemical vapor deposition and electrospinning techniques with subsequent chemical treatment. Meanwhile, the surfaces of CNFs are easy to modify with various materials to extend the applications of CNF-based hybrid nanomaterials in multiple fields. In this review, we focus on the design, synthesis, and sensor applications of CNF-based functional nanomaterials. The fabrication strategies of CNF-based functional nanomaterials by adding metallic nanoparticles (NPs), metal oxide NPs, alloy, silica, polymers, and others into CNFs are introduced and discussed. In addition, the sensor applications of CNF-based nanomaterials for detecting gas, strain, pressure, small molecule, and biomacromolecules are demonstrated in detail. This work will be beneficial for the readers to understand the strategies for fabricating various CNF-based nanomaterials, and explore new applications in energy, catalysis, and environmental science.
Collapse
Affiliation(s)
- Zhuqing Wang
- AnHui Provice Key Laboratory of Optoelectronic and Magnetism Functional Materials, Anqing Normal University, Anqing 246011, China
| | - Shasha Wu
- AnHui Provice Key Laboratory of Optoelectronic and Magnetism Functional Materials, Anqing Normal University, Anqing 246011, China
| | - Jian Wang
- AnHui Provice Key Laboratory of Optoelectronic and Magnetism Functional Materials, Anqing Normal University, Anqing 246011, China
| | - Along Yu
- AnHui Provice Key Laboratory of Optoelectronic and Magnetism Functional Materials, Anqing Normal University, Anqing 246011, China
| | - Gang Wei
- College of Chemistry and Chemical Engineering, Qingdao University, Qingdao 266077, China.
- Hybrid Materials Interfaces Group, Faculty of Production Engineering and Center for Environmental Research and Sustainable technology (UFT), University of Bremen, D-28359 Bremen, Germany.
| |
Collapse
|
9
|
Eissa S, Almthen RA, Zourob M. Disposable electrochemical immunosensor array for the multiplexed detection of the drug metabolites morphine, tetrahydrocannabinol and benzoylecgonine. Mikrochim Acta 2019; 186:523. [PMID: 31292788 DOI: 10.1007/s00604-019-3646-8] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2019] [Accepted: 06/27/2019] [Indexed: 01/07/2023]
Abstract
Heroin, marijuana and cocaine are widely abused drugs. Their use can be readily detected by analyzing urine for the metabolites morphine (MOR), tetrahydrocannabinol (THC) or benzoylecgonine (BZC). A multiplex immunosensor is described here for detection of MOR, THC and BZC using screen printed carbon array electrodes modified with gold nanoparticles. Antibodies against MOR, THC and BZC were immobilized on eight electrodes in a sensor array simultaneously, and a competitive assay was used for the detection. The free analytes in the sample compete with bovine serum albumin-conjugated analytes for the immobilized antibodies on the sensor surface. The array is capable of detecting the three drugs simultaneously within 20-40 min. The method has a high sensitivity, with detection limits as low as 1.2, 7.0, and 8.0 pg.mL-1 for MOR, THC and BZC, respectively. Cross reactivity testing was preformed to monitor any nonspecific binding. The results revealed good selectivity. Urine samples were spiked with the 3 drugs and tested with the multiplexed immunosensor. Recovery percentages ranged between 88 to 115%. Graphical abstract Schematic presentation of the multiplexed immunosensor for drugs of abuse,viz. tetrahydrocannabinol (THC), morphine (MOR), and benzoylecgonine (BZC)) by using an array of modified electrodes.
Collapse
Affiliation(s)
- Shimaa Eissa
- Department of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, AlTakhassusi Rd., Riyadh, 11533, Saudi Arabia
| | - Rema A Almthen
- Department of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, AlTakhassusi Rd., Riyadh, 11533, Saudi Arabia
| | - Mohammed Zourob
- Department of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, AlTakhassusi Rd., Riyadh, 11533, Saudi Arabia.
| |
Collapse
|
10
|
Yáñez-Sedeño P, Campuzano S, Pingarrón JM. Pushing the limits of electrochemistry toward challenging applications in clinical diagnosis, prognosis, and therapeutic action. Chem Commun (Camb) 2019; 55:2563-2592. [PMID: 30688320 DOI: 10.1039/c8cc08815b] [Citation(s) in RCA: 40] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Constant progress in the identification of biomarkers at different molecular levels in samples of different natures, and the need to conduct routine analyses, even in limited-resource settings involving simple and short protocols, are examples of the growing current clinical demands not satisfied by conventional available techniques. In this context, the unique features offered by electrochemical biosensors, including affordability, real-time and reagentless monitoring, simple handling and portability, and versatility, make them especially interesting for adaptation to the increasingly challenging requirements of current clinical and point-of-care (POC) diagnostics. This has allowed the continuous development of strategies with improved performance in the clinical field that were unthinkable just a few years ago. After a brief introduction to the types and characteristics of clinically relevant biomarkers/samples, requirements for their analysis, and currently available methodologies, this review article provides a critical discussion of the most important developments and relevant applications involving electrochemical biosensors reported in the last five years in response to the demands of current diagnostic, prognostic, and therapeutic actions related to high prevalence and high mortality diseases and disorders. Special attention is paid to the rational design of surface chemistry and the use/modification of state-of-the-art nanomaterials to construct electrochemical bioscaffolds with antifouling properties that can be applied to the single or multiplex determination of biomarkers of accepted or emerging clinical relevance in particularly complex clinical samples, such as undiluted liquid biopsies, whole cells, and paraffin-embedded tissues, which have scarcely been explored using conventional techniques or electrochemical biosensing. Key points guiding future development, challenges to be addressed to further push the limits of electrochemical biosensors towards new challenging applications, and their introduction to the market are also discussed.
Collapse
Affiliation(s)
- P Yáñez-Sedeño
- Departamento de Química Analítica, Facultad de CC. Químicas, Universidad Complutense de Madrid, E-28040 Madrid, Spain.
| | | | | |
Collapse
|
11
|
Xiong J, Feng J, Qiu L, Gao Z, Li P, Pang L, Zhang Z. SDF-1-loaded PLGA nanoparticles for the targeted photoacoustic imaging and photothermal therapy of metastatic lymph nodes in tongue squamous cell carcinoma. Int J Pharm 2019; 554:93-104. [DOI: 10.1016/j.ijpharm.2018.10.064] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2018] [Revised: 10/25/2018] [Accepted: 10/28/2018] [Indexed: 01/28/2023]
|