1
|
Li J, Guo Y. A sandwich chemiluminescent magnetic microparticle immunoassay for cryptococcal antigen detection. Expert Rev Mol Diagn 2024; 24:533-540. [PMID: 38879820 DOI: 10.1080/14737159.2024.2369243] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Accepted: 05/03/2024] [Indexed: 07/17/2024]
Abstract
BACKGROUND Cryptococcosis is a global invasive mycosis associated with significant morbidity and mortality. Cryptococcal antigen (CrAg) testing from serum and cerebrospinal fluid (CSF) has been regarded as a gold standard for early diagnosis. This study aimed to develop and validate a rapid and sensitive sandwich chemiluminescent magnetic microparticle immunoassay (CMIA) for quantitative detection of CrAg in sera. RESEARCH DESIGN AND METHODS CMIA is based on magnetic beads modified with capture antibodies and biotinylated antibodies and Streptavidin-polyHRP, where biotinylated antibodies functioned as the recognition element and Streptavidin-polyHRP as the signal component. Assay parameters were first optimized, and then assay performances were evaluated. RESULTS Under optimized conditions, the total runtime of the CMIA was 22 min. The assay had a wide linear range (2 -10,000 ng/mL) and high analytical sensitivity (0.24 ng/mL), together with acceptable reproducibility, accuracy, and stability. Besides, it exhibited no cross-reactivity with other pathogens. Importantly, the assay showed 92.91% (95% CI, 80.97-93.02%) overall qualitative agreement with a commercial ELISA kit in a retrospective cohort of 55 cases with confirmed cryptococcal infection, and 72 controls without evidence of invasive fungal disease (IFD). CONCLUSION These results demonstrated that the present study paved a novel strategy for reliable quantitative detection of CrAg in sera.
Collapse
Affiliation(s)
- Junpu Li
- The Clinical Laboratory of Tianjin Chest Hospital, Tianjin, P.R. China
| | - Yan Guo
- Department of Medical Ultrasound, Tianjin Medical University General Hospital, Tianjin, P.R. China
| |
Collapse
|
2
|
Ko A, Liao C. Paper-based colorimetric sensors for point-of-care testing. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:4377-4404. [PMID: 37641934 DOI: 10.1039/d3ay00943b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/31/2023]
Abstract
By eliminating the need for sample transportation and centralized laboratory analysis, point-of-care testing (POCT) enables on-the-spot testing, with results available within minutes, leading to improved patient management and overall healthcare efficiency. Motivated by the rapid development of POCT, paper-based colorimetric sensing, a powerful analytical technique that exploits the changes in color or absorbance of a chemical species to detect and quantify analytes of interest, has garnered increasing attention. In this review, we strive to provide a bird's eye view of the development landscape of paper-based colorimetric sensors that harness the unique properties of paper to create low-cost, easy-to-use, and disposable analytical devices, thematically covering both fundamental aspects and categorized applications. In the end, we authors summarized the review with the remaining challenges and emerging opportunities. Hopefully, this review will ignite new research endeavors in the realm of paper-based colorimetric sensors.
Collapse
Affiliation(s)
- Anthony Ko
- Renaissance Bio, New Territories, Hong Kong SAR, China.
- Medical School, Sun Yat-Sen University, Guangzhou, China
| | - Caizhi Liao
- Renaissance Bio, New Territories, Hong Kong SAR, China.
| |
Collapse
|
3
|
Dey MK, Iftesum M, Devireddy R, Gartia MR. New technologies and reagents in lateral flow assay (LFA) designs for enhancing accuracy and sensitivity. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:4351-4376. [PMID: 37615701 DOI: 10.1039/d3ay00844d] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/25/2023]
Abstract
Lateral flow assays (LFAs) are a popular method for quick and affordable diagnostic testing because they are easy to use, portable, and user-friendly. However, LFA design has always faced challenges regarding sensitivity, accuracy, and complexity of the operation. By integrating new technologies and reagents, the sensitivity and accuracy of LFAs can be improved while minimizing the complexity and potential for false positives. Surface enhanced Raman spectroscopy (SERS), photoacoustic techniques, fluorescence resonance energy transfer (FRET), and the integration of smartphones and thermal readers can improve LFA accuracy and sensitivity. To ensure reliable and accurate results, careful assay design and validation, appropriate controls, and optimization of assay conditions are necessary. Continued innovation in LFA technology is crucial to improving the reliability and accuracy of rapid diagnostic testing and expanding its applications to various areas, such as food testing, water quality monitoring, and environmental testing.
Collapse
Affiliation(s)
- Mohan Kumar Dey
- Department of Mechanical and Industrial Engineering, Louisiana State University, Baton Rouge, LA 70803, USA.
| | - Maria Iftesum
- Department of Mechanical and Industrial Engineering, Louisiana State University, Baton Rouge, LA 70803, USA.
| | - Ram Devireddy
- Department of Mechanical and Industrial Engineering, Louisiana State University, Baton Rouge, LA 70803, USA.
| | - Manas Ranjan Gartia
- Department of Mechanical and Industrial Engineering, Louisiana State University, Baton Rouge, LA 70803, USA.
| |
Collapse
|
4
|
Lu L, Hu X, Zeng R, Lin Q, Huang X, Wei Q, Tang D, Knopp D. Ag/MoO3–Pd-mediated gasochromic reaction: An efficient dual-mode photoelectrochemical and photothermal immunoassay. Biosens Bioelectron 2023; 230:115267. [PMID: 36996546 DOI: 10.1016/j.bios.2023.115267] [Citation(s) in RCA: 18] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2023] [Revised: 03/23/2023] [Accepted: 03/25/2023] [Indexed: 03/29/2023]
Abstract
Herein, we presented a dual-readout gasochromic immunosensing platform for accurate and sensitive detection of carcinoembryonic antigen (CEA) based on Ag-doped/Pd nanoparticles loaded MoO3 nanorods (Ag/MoO3-Pd). Initially, the presence of analyte CEA would prompt the formation of sandwich-type immunoreaction, accompanied by the introduction of Pt NPs labeled on detection antibody. Upon the addition of NH3BH3, the product hydrogen (H2) will interact with Ag/MoO3-Pd as a bridge between the sensing interface and the biological assembly platform. Both photocurrent and temperature signals can serve as readouts due to the significantly increased PEC performance and enhanced photothermal conversion capability of H-Ag/MoO3-Pd (the product of Ag/MoO3-Pd react with H2) compared to Ag/MoO3-Pd. In addition, the DFT results show that the band gap of Ag/MoO3-Pd becomes narrower after the reaction with H2, thus improving the utilization of light, which theoretically explains the internal mechanism of gas sensing reaction. Under optimal conditions, the designed immunosensing platform showed good sensitivity for CEA detection with the limit of detection (LOD) of 26 pg mL-1 (photoelectrochemical mode) and 98 pg mL-1 (photothermal mode). This work not only presents the possible reaction mechanism of Ag/MoO3-Pd and H2, but also creatively applicate it in photothermal biosensors that give a new path for devising dual-readout immunosensor.
Collapse
|
5
|
Pei F, Feng S, Hu W, Liu B, Mu X, Hao Q, Cao Y, Lei W, Tong Z. Sandwich mode lateral flow assay for point-of-care detecting SARS-CoV-2. Talanta 2023; 253. [PMCID: PMC9612878 DOI: 10.1016/j.talanta.2022.124051] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The global corona virus disease 2019 (COVID-19) has been announced a pandemic outbreak, and has threatened human life and health seriously. Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), as its causative pathogen, is widely detected in the screening of COVID-19 patients, infected people and contaminated substances. Lateral flow assay (LFA) is a popular point-of-care detection method, possesses advantages of quick response, simple operation mode, portable device, and low cost. Based on the above advantages, LFA has been widely developed for detecting SARS-CoV-2. In this review, we summarized the articles about the sandwich mode LFA detecting SARS-CoV-2, classified according to the target detection objects indicating genes, nucleocapsid protein, spike protein, and specific antibodies of SARS-CoV-2. In each part, LFA is further classified and summarized according to different signal detection types. Additionally, the properties of the targets were introduced to clarify their detection significance. The review is expected to provide a helpful guide for LFA sensitization and marker selection of SARS-CoV-2.
Collapse
Affiliation(s)
- Fubin Pei
- School of Chemistry and Chemical Engineering, Nanjing University of Science and Technology, Nanjing, 210094, Jiangsu, China,State Key Laboratory of NBC Protection for Civilian, Beijing, 102205, China
| | - Shasha Feng
- School of Chemistry and Chemical Engineering, Nanjing University of Science and Technology, Nanjing, 210094, Jiangsu, China,State Key Laboratory of NBC Protection for Civilian, Beijing, 102205, China
| | - Wei Hu
- State Key Laboratory of NBC Protection for Civilian, Beijing, 102205, China
| | - Bing Liu
- State Key Laboratory of NBC Protection for Civilian, Beijing, 102205, China
| | - Xihui Mu
- State Key Laboratory of NBC Protection for Civilian, Beijing, 102205, China
| | - Qingli Hao
- School of Chemistry and Chemical Engineering, Nanjing University of Science and Technology, Nanjing, 210094, Jiangsu, China
| | - Yang Cao
- School of Chemistry and Chemical Engineering, Nanjing University of Science and Technology, Nanjing, 210094, Jiangsu, China
| | - Wu Lei
- School of Chemistry and Chemical Engineering, Nanjing University of Science and Technology, Nanjing, 210094, Jiangsu, China,Corresponding author
| | - Zhaoyang Tong
- State Key Laboratory of NBC Protection for Civilian, Beijing, 102205, China,Corresponding author
| |
Collapse
|
6
|
Yu Z, Gong H, Xue F, Zeng Y, Liu X, Tang D. Flexible and High-Throughput Photothermal Biosensors for Rapid Screening of Acute Myocardial Infarction Using Thermochromic Paper-Based Image Analysis. Anal Chem 2022; 94:13233-13242. [PMID: 36099057 DOI: 10.1021/acs.analchem.2c02957] [Citation(s) in RCA: 33] [Impact Index Per Article: 16.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Herein, we developed a flexible, low-cost thermosensitive fiber paper for the visual display in photothermal biosensing systems for early acute myocardial infarction. The thermal signal visualization device was encapsulated with rewritable thermal fibers, which exhibited excellent stability and reversibility. The mechanism of color change in thermal paper was based on a temperature-driven reversible transformation of the structure of the dye molecule (crystalline violet lactone, CVL). It exhibits a gradation from blue to colorless at higher temperatures and gradually returns to blue when the temperature drops. Immobilization and cascade enzymatic reactions of target molecules occurred in an integrated 3D-printed detection device, a photothermal conversion process occurred under near-infrared light excitation, and the colorimetric change values of the encapsulated thermal paper were recorded and evaluated for possible pathogenicity using a smartphone. It was worth noting that the effect of the thermogenic ring-opening behavior of CVL on the macroscopic phenomenon of color change was obtained by density functional theory calculations. Under optimized conditions, the naked-eye-recognizable range of the thermal paper-based photothermal immunoassay sensor was 0.2-20 ng mL-1, This work creatively presents theoretical studies of promising thermal paper-based photothermal biosensors and provides new insights for the development of low-cost, instrument-free portable photothermal biosensors.
Collapse
Affiliation(s)
- Zhichao Yu
- Key Laboratory of Analytical Science for Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou 350108, People's Republic of China
| | - Hexiang Gong
- Key Laboratory of Analytical Science for Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou 350108, People's Republic of China
| | - Fangqin Xue
- Department of Gastrointestinal Surgery, Shengli Clinical Medical College of Fujian Medical University, Fujian Provincial Hospital, No. 134 Dongjie, Fuzhou 350001, People's Republic of China
| | - Yongyi Zeng
- The United Innovation of Mengchao Hepatobiliary Technology Key Laboratory of Fujian Province, Mengchao Hepatobiliary Hospital of Fujian Medical University, Fuzhou 350025, People's Republic of China
| | - Xiaolong Liu
- The United Innovation of Mengchao Hepatobiliary Technology Key Laboratory of Fujian Province, Mengchao Hepatobiliary Hospital of Fujian Medical University, Fuzhou 350025, People's Republic of China
| | - Dianping Tang
- Key Laboratory of Analytical Science for Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou 350108, People's Republic of China
| |
Collapse
|
7
|
Rotake D, Pratim Goswami P, Govind Singh S. Ultraselective, ultrasensitive, point-of-care electrochemical sensor for detection of Hg(II) ions with electrospun-InZnO nanofibers. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116350] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
8
|
Development of SERS-based immunoassay for the detection of cryptococcosis biomarker. Anal Bioanal Chem 2022; 414:4645-4654. [PMID: 35441260 DOI: 10.1007/s00216-022-04081-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2022] [Revised: 04/07/2022] [Accepted: 04/08/2022] [Indexed: 11/01/2022]
Abstract
The surface-enhanced Raman scattering (SERS) technique has displayed a broad application prospect in disease diagnosis owing to its high sensitivity, fast responsiveness, and high specificity. In this study, we developed a SERS-based immunoassay for the detection of cryptococcal capsular polysaccharide (glucuronoxylomannan, GXM), which is an important biomarker of cryptococcosis. The coupled localized surface plasmon resonance effect between magnetic SERS substrates and SERS tags gave rise to an enhanced Raman signal upon the formation of sandwich complexes, which contributes to the sensitive and specific detection of GXM. As a result, the developed method provided a lower limit of detection (1.25 ng/mL) than conventional methods, such as latex agglutination, lateral flow assay, and enzyme-linked immunosorbent assay. Additionally, a recovery experiment was performed to detect GXM in human serum, which also validated the potential advantages of a SERS-based immunoassay in the clinical diagnosis of cryptococcosis.
Collapse
|
9
|
Hoang TX, Phan LMT, Vo TAT, Cho S. Advanced Signal-Amplification Strategies for Paper-Based Analytical Devices: A Comprehensive Review. Biomedicines 2021; 9:biomedicines9050540. [PMID: 34066112 PMCID: PMC8150371 DOI: 10.3390/biomedicines9050540] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2021] [Revised: 05/05/2021] [Accepted: 05/10/2021] [Indexed: 11/21/2022] Open
Abstract
Paper-based analytical devices (PADs) have emerged as a promising approach to point-of-care (POC) detection applications in biomedical and clinical diagnosis owing to their advantages, including cost-effectiveness, ease of use, and rapid responses as well as for being equipment-free, disposable, and user-friendly. However, the overall sensitivity of PADs still remains weak, posing a challenge for biosensing scientists exploiting them in clinical applications. This review comprehensively summarizes the current applicable potential of PADs, focusing on total signal-amplification strategies that have been applied widely in PADs involving colorimetry, luminescence, surface-enhanced Raman scattering, photoacoustic, photothermal, and photoelectrochemical methods as well as nucleic acid-mediated PAD modifications. The advances in signal-amplification strategies in terms of signal-enhancing principles, sensitivity, and time reactions are discussed in detail to provide an overview of these approaches to using PADs in biosensing applications. Furthermore, a comparison of these methods summarizes the potential for scientists to develop superior PADs. This review serves as a useful inside look at the current progress and prospective directions in using PADs for clinical diagnostics and provides a better source of reference for further investigations, as well as innovations, in the POC diagnostics field.
Collapse
Affiliation(s)
- Thi Xoan Hoang
- Department of Life Science, Gachon University, Seongnam 13120, Gyeonggi-do, Korea; (T.X.H.); (T.A.T.V.)
| | - Le Minh Tu Phan
- Department of Electronic Engineering, Gachon University, Seongnam 13120, Gyeonggi-do, Korea
- School of Medicine and Pharmacy, The University of Danang, Danang 550000, Vietnam
- Correspondence: (L.M.T.P.); (S.C.)
| | - Thuy Anh Thu Vo
- Department of Life Science, Gachon University, Seongnam 13120, Gyeonggi-do, Korea; (T.X.H.); (T.A.T.V.)
| | - Sungbo Cho
- Department of Electronic Engineering, Gachon University, Seongnam 13120, Gyeonggi-do, Korea
- Department of Health Sciences and Technology, GAIHST, Gachon University, Incheon 21999, Korea
- Correspondence: (L.M.T.P.); (S.C.)
| |
Collapse
|
10
|
Liu Y, Zhan L, Qin Z, Sackrison J, Bischof JC. Ultrasensitive and Highly Specific Lateral Flow Assays for Point-of-Care Diagnosis. ACS NANO 2021; 15:3593-3611. [PMID: 33607867 DOI: 10.1021/acsnano.0c10035] [Citation(s) in RCA: 221] [Impact Index Per Article: 73.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Lateral flow assays (LFAs) are paper-based point-of-care (POC) diagnostic tools that are widely used because of their low cost, ease of use, and rapid format. Unfortunately, traditional commercial LFAs have significantly poorer sensitivities (μM) and specificities than standard laboratory tests (enzyme-linked immunosorbent assay, ELISA: pM-fM; polymerase chain reaction, PCR: aM), thus limiting their impact in disease control. In this Perspective, we review the evolving efforts to increase the sensitivity and specificity of LFAs. Recent work to improve the sensitivity through assay improvement includes optimization of the assay kinetics and signal amplification by either reader systems or additional reagents. Together, these efforts have produced LFAs with ELISA-level sensitivities (pM-fM). In addition, sample preamplification can be applied to both nucleic acids (direct amplification) and other analytes (indirect amplification) prior to LFA testing, which can lead to PCR-level (aM) sensitivity. However, these amplification strategies also increase the detection time and assay complexity, which inhibits the large-scale POC use of LFAs. Perspectives to achieve future rapid (<30 min), ultrasensitive (PCR-level), and "sample-to-answer" POC diagnostics are also provided. In the case of LFA specificity, recent research efforts have focused on high-affinity molecules and assay optimization to reduce nonspecific binding. Furthermore, novel highly specific molecules, such as CRISPR/Cas systems, can be integrated into diagnosis with LFAs to produce not only ultrasensitive but also highly specific POC diagnostics. In summary, with continuing improvements, LFAs may soon offer performance at the POC that is competitive with laboratory techniques while retaining a rapid format.
Collapse
Affiliation(s)
- Yilin Liu
- Department of Mechanical Engineering, University of Minnesota, Minneapolis, Minnesota 55455, United States
| | - Li Zhan
- Department of Mechanical Engineering, University of Minnesota, Minneapolis, Minnesota 55455, United States
| | - Zhenpeng Qin
- Department of Mechanical Engineering, University of Texas at Dallas, Richardson, Texas 75080 United States
- Department of Bioengineering, University of Texas at Dallas, Richardson, Texas 75080, United States
- Department of Surgery, University of Texas Southwestern Medical Center, Dallas, Texas 75390, United States
- Center for Advanced Pain Studies, University of Texas at Dallas, Richardson, Texas 75080, United States
| | - James Sackrison
- 3984 Hunters Hill Way, Minnetonka, Minnesota 55345, United States
| | - John C Bischof
- Department of Mechanical Engineering, University of Minnesota, Minneapolis, Minnesota 55455, United States
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, Minnesota 55455, United States
- Director, Institute of Engineering in Medicine, University of Minnesota, Minneapolis, Minnesota 55455, United States
| |
Collapse
|
11
|
Recent advances in sensitivity enhancement for lateral flow assay. Mikrochim Acta 2021; 188:379. [PMID: 34647157 PMCID: PMC8513549 DOI: 10.1007/s00604-021-05037-z] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Accepted: 09/25/2021] [Indexed: 12/04/2022]
Abstract
Conventional lateral flow assay (LFA) is typically performed by observing the color changes in the test lines by naked eyes, which achieves considerable commercial success and has a significant impact on the fields of food safety, environment monitoring, disease diagnosis, and other applications. However, this qualitative detection method is not very suitable for low levels of disease biomarkers' detection. Although many nanomaterials are used as new labels for LFA, additional readers limit their application to some extent. Fortunately, a lot of work has been done for improving the sensitivity of LFA. In this review, currently reported LFA sensitivity enhancement methods with an objective evaluation are summarized, such as sample pretreatment, the change of flow rate, and label evolution, and future development direction and challenges of LFAs are discussed.
Collapse
|
12
|
Guo H, Su X, Su Q, Zhuang W, You Z. Au-coated Fe 3O 4 core-shell nanohybrids with photothermal activity for point-of-care immunoassay for lipoprotein-associated phospholipase A 2 on a digital near-infrared thermometer. Anal Bioanal Chem 2020; 413:235-244. [PMID: 33048173 DOI: 10.1007/s00216-020-02995-w] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2020] [Revised: 09/24/2020] [Accepted: 10/06/2020] [Indexed: 12/23/2022]
Abstract
A portable photothermal immunoassay based on Au-coated magnetic Fe3O4 core-shell nanohybrids (Au-Fe3O4) was developed for point-of-care (POC) testing of lipoprotein-associated phospholipase A2 (Lp-PLA2) on a digital near-infrared (NIR) thermometer. Au-Fe3O4 photothermal materials were first synthesized through reverse micelle method, and then functionalized with polyclonal rabbit anti-human Lp-PLA2 antibody. A sandwiched immunoreaction was carried out in polyclonal mouse anti-human Lp-PLA2 antibody-coated microplate using Au-Fe3O4-labeled antibody as the detection antibody. With formation of sandwich-type immunocomplex, the captured Au-Fe3O4 on the plate converted the light into heat under an 808-nm laser irradiation (1.5 W cm-2), thereby resulting in the increasing temperature of the detection solution. The temperature variations relative to surrounding temperature was determined on a portable NIR thermometer. Several labeling protocols with gold nanoparticle, Fe3O4 nanoparticle, or Au-Fe3O4 nanohybrids were investigated for determination of Lp-PLA2 and improved analytical features were achieved with the core-shell Au-Fe3O4 nanohybrids. Under optimum conditions, Au-Fe3O4-based immunoassay exhibited good photothermal responses for the detection of Lp-PLA2 with a dynamic linear range of 0.01-100 ng mL-1 at a low detection limit of 8.6 pg mL-1. Good reproducibility and intermediate precision were less than 9.7%. Other biomarkers or proteins did not interfere with responses of this system. An acceptable accuracy was acquired for analysis of human serum sample between Au-Fe3O4-based photothermal immunoassay and commercialized human Lp-PLA2 ELISA kit.
Collapse
Affiliation(s)
- Haixin Guo
- Department of Ultrasound, The Second Affiliated Hospital of Fujian Medical University, Quanzhou, 362000, Fujian, China
| | - Xiaoping Su
- Department of Urology, The Second Affiliated Hospital of Fujian Medical University, Quanzhou, 362000, Fujian, China
| | - Qingfu Su
- Department of Urology, The Second Affiliated Hospital of Fujian Medical University, Quanzhou, 362000, Fujian, China
| | - Wei Zhuang
- Department of Urology, The Second Affiliated Hospital of Fujian Medical University, Quanzhou, 362000, Fujian, China
| | - Zhijiao You
- Department of Urology, Jinjiang Municipal Hospital, No. 392, Xinhua Street, Jinjiang City, 362200, Fujian, China.
| |
Collapse
|
13
|
Rotake DR, Kumar A, Darji AD, Singh J. Highly selective sensor for the detection of Hg 2+ ions using homocysteine functionalised quartz crystal microbalance with cross-linked pyridinedicarboxylic acid. IET Nanobiotechnol 2020; 14:563-573. [PMID: 33010131 PMCID: PMC8676536 DOI: 10.1049/iet-nbt.2020.0109] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2020] [Revised: 05/18/2020] [Accepted: 06/02/2020] [Indexed: 01/23/2023] Open
Abstract
This study reports an insightful portable vector network analyser (VNA)-based measurement technique for quick and selective detection of Hg2+ ions in nanomolar (nM) range using homocysteine (HCys)-functionalised quartz-crystal-microbalance (QCM) with cross-linked-pyridinedicarboxylic acid (PDCA). The excessive exposure to mercury can cause damage to many human organs, such as the brain, lungs, stomach, and kidneys, etc. Hence, the authors have proposed a portable experimental platform capable of achieving the detection in 20-30 min with a limit of detection (LOD) 0.1 ppb (0.498 nM) and a better dynamic range (0.498 nM-6.74 mM), which perfectly describes its excellent performance over other reported techniques. The detection time for various laboratory-based techniques is generally 12-24 h. The proposed method used the benefits of thin-film, nanoparticles (NPs), and QCM-based technology to overcome the limitation of NPs-based technique and have LOD of 0.1 ppb (0.1 μg/l) for selective Hg2+ ions detection which is many times less than the World Health Organization limit of 6 μg/l. The main advantage of the proposed QCM-based platform is its portability, excellent repeatability, millilitre sample volume requirement, and easy process flow, which makes it suitable as an early warning system for selective detection of mercury ions without any costly measuring instruments.
Collapse
Affiliation(s)
- Dinesh Ramkrushna Rotake
- Electronics Engineering Department, Sardar Vallabhbhai National Institute of Technology, Surat, Gujarat, India.
| | - Ajay Kumar
- Smart Sensors Area, CSIR-Central Electronics Engineering Research Institute, Pilani-333031, Rajasthan, India
| | - Anand D Darji
- Electronics Engineering Department, Sardar Vallabhbhai National Institute of Technology, Surat, Gujarat, India
| | - Jitendra Singh
- Smart Sensors Area, CSIR-Central Electronics Engineering Research Institute, Pilani-333031, Rajasthan, India
| |
Collapse
|
14
|
Ye H, Liu Y, Zhan L, Liu Y, Qin Z. Signal amplification and quantification on lateral flow assays by laser excitation of plasmonic nanomaterials. Theranostics 2020; 10:4359-4373. [PMID: 32292500 PMCID: PMC7150487 DOI: 10.7150/thno.44298] [Citation(s) in RCA: 52] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2020] [Accepted: 02/23/2020] [Indexed: 12/14/2022] Open
Abstract
Lateral flow assay (LFA) has become one of the most widely used point-of-care diagnostic methods due to its simplicity and low cost. While easy to use, LFA suffers from its low sensitivity and poor quantification, which largely limits its applications for early disease diagnosis and requires further testing to eliminate false-negative results. Over the past decade, signal enhancement strategies that took advantage of the laser excitation of plasmonic nanomaterials have pushed down the detection limit and enabled quantification of analytes. Significantly, these methods amplify the signal based on the current LFA design without modification. This review highlights these strategies of signal enhancement for LFA including surface enhanced Raman scattering (SERS), photothermal and photoacoustic methods. Perspectives on the rational design of the reader systems are provided. Future translation of the research toward clinical applications is also discussed.
Collapse
Affiliation(s)
- Haihang Ye
- Department of Mechanical Engineering, University of Texas at Dallas, Richardson, Texas 75080, USA
| | - Yaning Liu
- Department of Mechanical Engineering, University of Texas at Dallas, Richardson, Texas 75080, USA
| | - Li Zhan
- Department of Mechanical Engineering, University of Minnesota, 111 Church Street SE, Minneapolis, Minnesota 55455, USA
| | - Yilin Liu
- Department of Mechanical Engineering, University of Minnesota, 111 Church Street SE, Minneapolis, Minnesota 55455, USA
| | - Zhenpeng Qin
- Department of Mechanical Engineering, University of Texas at Dallas, Richardson, Texas 75080, USA
- Department of Bioengineering, University of Texas at Dallas, Richardson, Texas 75080, USA
- Center for Advanced Pain Studies, University of Texas at Dallas, Richardson, Texas 75080, USA
- Department of Surgery, The University of Texas Southwestern Medical Center, 5323 Harry Lines Blvd, Dallas, Texas 75390, USA
| |
Collapse
|
15
|
Recent advances in high-sensitivity detection methods for paper-based lateral-flow assay. Biosens Bioelectron 2020; 152:112015. [PMID: 32056735 DOI: 10.1016/j.bios.2020.112015] [Citation(s) in RCA: 171] [Impact Index Per Article: 42.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2019] [Revised: 01/02/2020] [Accepted: 01/08/2020] [Indexed: 12/19/2022]
Abstract
Paper-based lateral-flow assays (LFAs) have achieved considerable commercial success and continue to have a significant impact on medical diagnostics and environmental monitoring. Conventional LFAs are typically performed by examining the color changes in the test bands by naked eye. However, for critical biochemical markers that are present in extremely small amounts in the clinical specimens, this readout method is not quantitative, and does not provide sufficient sensitivity or suitable detection limit for a reliable assay. Diverse technologies for high-sensitivity LFA detection have been developed and commercialization efforts are underway. In this review, we aim to provide a critical and objective overview of the recent progress in high-sensitivity LFA detection technologies, which involve the exploitation of the physical and chemical responses of transducing particles. The features and biomedical applications of the technologies, along with future prospects and challenges, are also discussed.
Collapse
|
16
|
Ultra-sensitive capillary immunosensor combining porous-layer surface modification and biotin-streptavidin nano-complex signal amplification: Application for sensing of procalcitonin in serum. Talanta 2019; 205:120089. [DOI: 10.1016/j.talanta.2019.06.089] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2019] [Revised: 06/21/2019] [Accepted: 06/26/2019] [Indexed: 12/19/2022]
|
17
|
Han X, Cao M, Wu M, Wang YJ, Yu C, Zhang C, Yu H, Wei JF, Li L, Huang W. A paper-based chemiluminescence immunoassay device for rapid and high-throughput detection of allergen-specific IgE. Analyst 2019; 144:2584-2593. [PMID: 30830127 DOI: 10.1039/c8an02020e] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
The fast and precise detection of potential allergen-specific immunoglobulin E (sIgE) is imperative for the diagnosis and appropriate treatment of allergic diseases. In this study, we have successfully fabricated a novel paper-based immunoassay device for the detection of sIgE in allergic diseases. We used Can f 1, one of the main dog allergens, as a model allergen to detect sIgE in human sera. To achieve excellent performance, the experimental parameters were optimized. Further, we extended this device for potential applications in the clinical diagnosis of allergic diseases: worthwhile clinical performance in the detection of allergens was achieved as compared to that achieved by commercial enzyme-linked immunosorbent assay (ELISA) kit. Therefore, it was proven that this strategy has the advantages of high-throughput, rapid, sensitive, and highly accurate detection of trace amounts of sIgEs. Furthermore, by simply changing the antigen and antibody, this device could be used for the high-throughput detection of other allergens, so as to achieve multiallergen detection and appropriate desensitization therapy, thereby making it promising in the determination of allergic diseases in clinics.
Collapse
Affiliation(s)
- Xisi Han
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211800, P. R. China.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
18
|
Mahmoudi T, de la Guardia M, Shirdel B, Mokhtarzadeh A, Baradaran B. Recent advancements in structural improvements of lateral flow assays towards point-of-care testing. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2019.04.016] [Citation(s) in RCA: 66] [Impact Index Per Article: 13.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
|
19
|
Li S, Zhang Y, Wen W, Sheng W, Wang J, Wang S, Wang J. A high-sensitivity thermal analysis immunochromatographic sensor based on au nanoparticle-enhanced two-dimensional black phosphorus photothermal-sensing materials. Biosens Bioelectron 2019; 133:223-229. [PMID: 30951982 DOI: 10.1016/j.bios.2019.03.039] [Citation(s) in RCA: 53] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2019] [Revised: 03/15/2019] [Accepted: 03/18/2019] [Indexed: 11/17/2022]
Abstract
For the first time, a quantitative photothermal-sensing immunochromatographic sensor (PT-ICS) is described using Au nanoparticle-enhanced two-dimensional black phosphorus (BP-Au) as signal component for the photothermal-sensing antibody probe. BP-Au has good photothermal properties at 808 nm, and the photothermal conversion efficiency of the BP-Au nanosheet increased by 12.9% over the black phosphorus nanosheet alone. In addition, the antibody was more easily coupled to this nanosheet due to the good physical adsorption capacity of Au nanoparticles. We used this PT-ICS to detect veterinary antibiotics enrofloxacin (ENR), the photothermal-sensing antibody probe was competitive captured by ENR target and antigen coating on test (T) lines of the sensor. This process was exothermic under an 808 nm laser, and the thermal energy decreased as the ENR in the sample increased. This thermal energy was recorded by an infrared thermal imager or an infrared thermometer, and the concentration of the ENR residues in animal-derived foods was obtained by analyzing the temperature changes in T-lines. Under optimal conditions, the PT-ICS exhibited sensitive and specific detection of ENR from 0.03 μg/L to 10 μg/L with detection limits of 0.023 μg/L. The results agreed well with a commercial enzyme-linked-immunosorbent assay kit. This PT-ICS provided a promising strategy for the detection of ENR residues in animal-derived foods and expected to be used for the detection of other highly sensitive biomacromolecules.
Collapse
Affiliation(s)
- Shijie Li
- State Key Laboratory for Food Nutrition and Safety; College of Food Engineering and Biotechnology, Tianjin University of Science and Technology, Tianjin 300457, PR China
| | - Ying Zhang
- State Key Laboratory for Food Nutrition and Safety; College of Food Engineering and Biotechnology, Tianjin University of Science and Technology, Tianjin 300457, PR China
| | - Wenjun Wen
- State Key Laboratory for Food Nutrition and Safety; College of Food Engineering and Biotechnology, Tianjin University of Science and Technology, Tianjin 300457, PR China
| | - Wei Sheng
- State Key Laboratory for Food Nutrition and Safety; College of Food Engineering and Biotechnology, Tianjin University of Science and Technology, Tianjin 300457, PR China
| | - Junying Wang
- The Biotechnology Research Institute of Chinese Academy of Agricultural Sciences, Beijing 10010, PR China
| | - Shuo Wang
- Beijing Technology and Business University, Higher Education Garden, Liangxiang, Beijing 100035, PR China.
| | - Junping Wang
- State Key Laboratory for Food Nutrition and Safety; College of Food Engineering and Biotechnology, Tianjin University of Science and Technology, Tianjin 300457, PR China.
| |
Collapse
|