1
|
Wang W, He Y, He S, Deng L, Wang H, Cao Z, Feng Z, Xiong B, Yin Y. A Brief Review of Aptamer-Based Biosensors in Recent Years. BIOSENSORS 2025; 15:120. [PMID: 39997022 PMCID: PMC11852377 DOI: 10.3390/bios15020120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/13/2024] [Revised: 02/11/2025] [Accepted: 02/13/2025] [Indexed: 02/26/2025]
Abstract
Aptamers have recently become novel probes for biosensors because of their good biocompatibility, strong specificity, and high sensitivity. Biosensors based on peptides or nucleic acid aptamers are used in implantable and wearable devices owing to their ease of synthesis and economic efficiency. Simultaneously, amphoteric ionic peptides are being explored as antifouling layers for biosensors resistant to interference from extraneous proteins in serum. Thus, this paper reviews recently developed aptamer-based biosensors and introduces peptide- and nucleic acid-based biosensors, while focusing on the three primary classes of biosensors: electrochemical sensors, fluorescent or colorimetric biosensors, and electroluminescent sensors. Furthermore, we summarize their general construction strategies, describe specific electrochemical sensors that use peptides as an antipollution layer, and elucidate their advantages.
Collapse
Affiliation(s)
- Wenjing Wang
- Key Laboratory of Agro-Ecological Processes in Subtropical Region, Institute of Subtropical Agriculture, Chinese Academy of Sciences, Changsha 410125, China; (W.W.); (Y.H.); (S.H.); (Y.Y.)
- Zhongke Jieyun (Beijing) Information Technology Co., Ltd., Beijing 101400, China
| | - Yumin He
- Key Laboratory of Agro-Ecological Processes in Subtropical Region, Institute of Subtropical Agriculture, Chinese Academy of Sciences, Changsha 410125, China; (W.W.); (Y.H.); (S.H.); (Y.Y.)
- Department of Biochemistry and Molecular Biology, Hengyang Medical School, University of South China, Hengyang 421001, China
| | - Suxiang He
- Key Laboratory of Agro-Ecological Processes in Subtropical Region, Institute of Subtropical Agriculture, Chinese Academy of Sciences, Changsha 410125, China; (W.W.); (Y.H.); (S.H.); (Y.Y.)
- College of Chemistry and Materials Science, Hunan Agricultural University, Changsha 410128, China
| | - Lei Deng
- School of Computer Science and Engineering, Central South University, Changsha 410075, China;
| | - Hui Wang
- State Key Laboratory of Animal Nutrition, Institute of Animal Science, Chinese Academy of Agricultural Sciences, Beijing 100193, China; (H.W.); (B.X.)
| | - Zhong Cao
- Hunan Provincial Key Laboratory of Cytochemistry, School of Chemistry and Biological Engineering, Changsha University of Science and Technology, Changsha 410114, China;
| | - Zemeng Feng
- Key Laboratory of Agro-Ecological Processes in Subtropical Region, Institute of Subtropical Agriculture, Chinese Academy of Sciences, Changsha 410125, China; (W.W.); (Y.H.); (S.H.); (Y.Y.)
| | - Benhai Xiong
- State Key Laboratory of Animal Nutrition, Institute of Animal Science, Chinese Academy of Agricultural Sciences, Beijing 100193, China; (H.W.); (B.X.)
| | - Yulong Yin
- Key Laboratory of Agro-Ecological Processes in Subtropical Region, Institute of Subtropical Agriculture, Chinese Academy of Sciences, Changsha 410125, China; (W.W.); (Y.H.); (S.H.); (Y.Y.)
| |
Collapse
|
2
|
Khan A, Anwar M, Rehman AU, Shokouhimehr M, Reis NM, Kalhoro KA, Zhang C, Liu Z. Biorecognition-based electrochemical sensors for highly sensitive C-reactive protein detection: A review. Int J Biol Macromol 2025; 304:140829. [PMID: 39938854 DOI: 10.1016/j.ijbiomac.2025.140829] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2024] [Revised: 01/23/2025] [Accepted: 02/07/2025] [Indexed: 02/14/2025]
Abstract
Highly sensitive C-reactive protein (hsCRP) is a widely recognized biomarker for inflammation and cardiovascular diseases and plays a critical role in early diagnosis, risk assessment, and treatment monitoring. The development of sensitive and selective techniques for hsCRP detection is of paramount importance for clinical diagnostics. Electrochemical sensors have emerged as promising alternatives to traditional methods, offering rapid, cost-effective, and portable solutions for hsCRP analysis. This review comprehensively discusses advancements in biorecognition-based electrochemical sensors for hsCRP detection, focusing on label- and label-free approaches. This review highlights the sensor principles, designs, and performance, and emphasizes their advantages as well as limitations in various target applications. Recent studies have shown the potential of both label- and label-free-based sensors to achieve low detection limits and wide linear ranges comparable to traditional methods. In addition, we discuss the mechanisms, challenges, and future directions of biorecognition-based electrochemical sensors for hsCRP detection. This innovation can potentially revolutionize the diagnosis and treatment of cardiovascular and inflammatory diseases by enhancing the detection sensitivity and specificity. Ultimately, these advancements aim to improve patient outcomes by enabling earlier diagnosis, cost-effectiveness, and more precise monitoring, contributing to more effective management of cardiovascular health globally.
Collapse
Affiliation(s)
- Adil Khan
- School of Electronic Information, Central South University, Changsha 410083, China; School of Physics, Central South University, Changsha 410083, China
| | - Muhammad Anwar
- School of Electronic Information, Central South University, Changsha 410083, China; School of Physics, Central South University, Changsha 410083, China
| | - Atiq Ur Rehman
- School of Physics, Central South University, Changsha 410083, China
| | - Mohammadreza Shokouhimehr
- Department of Materials Science and Engineering, Research Institute of Advanced Materials, Seoul National University, Seoul 08826, Republic of Korea; Institute of Nanosensor Technology, Hanyang University, Ansan 15588, Republic of Korea
| | - Nuno M Reis
- Department of Chemical Engineering and Centre for Bioengineering & Biomedical Technologies (CBio), University of Bath, Claverton Down, Bath BA2 7AY, UK
| | - Kashif Ali Kalhoro
- School of Electronic Information, Central South University, Changsha 410083, China; School of Physics, Central South University, Changsha 410083, China; Sukkur IBA University, Sukkur 65200, Pakistan
| | - Chi Zhang
- School of Electronic Information, Central South University, Changsha 410083, China; School of Physics, Central South University, Changsha 410083, China
| | - Zhengchun Liu
- School of Electronic Information, Central South University, Changsha 410083, China; School of Physics, Central South University, Changsha 410083, China.
| |
Collapse
|
3
|
Lv J, Wan J, Wu D, Zhang X, Xu W, Wang M, Chen S, Ye Z, Tian Y, Hu Q, Han D, Niu L. Target-mediated silver deposition-based electrochemical biosensor for highly sensitive detection of human chorionic gonadotropin. Biosens Bioelectron 2025; 267:116830. [PMID: 39368294 DOI: 10.1016/j.bios.2024.116830] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2024] [Revised: 09/25/2024] [Accepted: 09/30/2024] [Indexed: 10/07/2024]
Abstract
As a glycoprotein hormone, human chorionic gonadotropin (hCG) is an established marker for pregnancy test. On the basis of the target-mediated silver deposition (TSD), in this work, we report the development of an amplification-free electrochemical biosensor for the highly sensitive detection of hCG. The detection of hCG involves the use of the affinity peptide-modified electrode for hCG capture (the CGGSSPPLRINRHILTR peptide containing the hCG-binding domain of the PPLRINRHILTR sequence is used as the affinity peptide), the oxidation of the diol sites of the glycan chains on hCG hormones into aldehyde groups by NaIO4, and the deposition of silver nanoparticles (AgNPs) for the solid-state voltammetric stripping analysis. Due to the deposition of multiple AgNPs while the solid-state Ag/AgCl voltammetric process has a high signal-to-noise ratio, the TSD-based electrochemical biosensor can be applied to the highly sensitive detection of hCG without the need for signal amplification. Under optimal conditions, the stripping current increased linearly with an increasing hCG concentration over the range from 1.0 to 25 mIU/mL, with a detection limit of 0.45 mIU/mL. Owing to the high specificity of the hCG-binding peptide PPLRINRHILTR, this electrochemical hCG biosensor exhibits high selectivity. The results of the quantitative assay of hCG in urine samples at the concentrations of 25, 10, and 1.0 mIU/mL are desirable, indicating the good anti-interference capability. As the TSD-based electrochemical biosensor allows the amplification-free detection of low-abundance hCG, it is easy to use and cost-effective, showing great promise in point-of-care assay of hCG for pregnancy test.
Collapse
Affiliation(s)
- Junpeng Lv
- Center for Advanced Analytical Science, Guangzhou Key Laboratory of Sensing Materials and Devices, Guangdong Engineering Technology Research Center for Sensing Materials and Devices, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou, 510006, PR China
| | - Jianwen Wan
- Center for Advanced Analytical Science, Guangzhou Key Laboratory of Sensing Materials and Devices, Guangdong Engineering Technology Research Center for Sensing Materials and Devices, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou, 510006, PR China
| | - Di Wu
- Center for Advanced Analytical Science, Guangzhou Key Laboratory of Sensing Materials and Devices, Guangdong Engineering Technology Research Center for Sensing Materials and Devices, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou, 510006, PR China
| | - Xiyao Zhang
- Center for Advanced Analytical Science, Guangzhou Key Laboratory of Sensing Materials and Devices, Guangdong Engineering Technology Research Center for Sensing Materials and Devices, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou, 510006, PR China
| | - Wenhui Xu
- Center for Advanced Analytical Science, Guangzhou Key Laboratory of Sensing Materials and Devices, Guangdong Engineering Technology Research Center for Sensing Materials and Devices, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou, 510006, PR China
| | - Mengge Wang
- Center for Advanced Analytical Science, Guangzhou Key Laboratory of Sensing Materials and Devices, Guangdong Engineering Technology Research Center for Sensing Materials and Devices, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou, 510006, PR China
| | - Songmin Chen
- Center for Advanced Analytical Science, Guangzhou Key Laboratory of Sensing Materials and Devices, Guangdong Engineering Technology Research Center for Sensing Materials and Devices, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou, 510006, PR China
| | - Zhuojun Ye
- Center for Advanced Analytical Science, Guangzhou Key Laboratory of Sensing Materials and Devices, Guangdong Engineering Technology Research Center for Sensing Materials and Devices, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou, 510006, PR China
| | - Yiyan Tian
- Center for Advanced Analytical Science, Guangzhou Key Laboratory of Sensing Materials and Devices, Guangdong Engineering Technology Research Center for Sensing Materials and Devices, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou, 510006, PR China
| | - Qiong Hu
- Center for Advanced Analytical Science, Guangzhou Key Laboratory of Sensing Materials and Devices, Guangdong Engineering Technology Research Center for Sensing Materials and Devices, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou, 510006, PR China.
| | - Dongxue Han
- Center for Advanced Analytical Science, Guangzhou Key Laboratory of Sensing Materials and Devices, Guangdong Engineering Technology Research Center for Sensing Materials and Devices, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou, 510006, PR China
| | - Li Niu
- Center for Advanced Analytical Science, Guangzhou Key Laboratory of Sensing Materials and Devices, Guangdong Engineering Technology Research Center for Sensing Materials and Devices, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou, 510006, PR China.
| |
Collapse
|
4
|
Svigelj R, de Marco A. Biological and technical factors affecting the point-of-care diagnostics in not-oncological chronic diseases. Biosens Bioelectron 2024; 264:116669. [PMID: 39146770 DOI: 10.1016/j.bios.2024.116669] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2024] [Revised: 08/05/2024] [Accepted: 08/12/2024] [Indexed: 08/17/2024]
Abstract
Inexpensive point-of-care (POC) analytical solutions have the potential to allow the implementation of large-scale screening campaigns aimed at identifying the initial stages of pathologies in the population, reducing morbidity, mortality and, indirectly, also the costs for the healthcare system. At global level, the most common preventive screening schemes address some cancer pathologies or are used to monitor the spread of some infective diseases. However, systematic testing might become decisive to improve the care response even in the case of chronic pathologies and, in this review, we analyzed the state-of-the-art of the POC diagnostics for Chronic Kidney Disease, Chronic Obstructive Pulmonary Disease and Multiple Sclerosis. The different technological options used to manufacture the biosensors and evaluate the produced data have been described and this information has been integrated with the present knowledge relatively to the biomarkers that have been proposed to monitor such diseases, namely their availability and reliability. Finally, the nature of the macromolecules used to capture the biomarkers has been discussed in relation to the biomarker nature.
Collapse
Affiliation(s)
- Rossella Svigelj
- Department of Agrifood, Environmental and Animal Sciences, University of Udine, Via Cotonificio 108, 33100, Udine, Italy
| | - Ario de Marco
- Lab of Environmental and Life Sciences, University of Nova Gorica, Vipavska Cesta 13, 5000, Nova Gorica, Slovenia.
| |
Collapse
|
5
|
Cho CH, Kim JH, Padalkar NS, Reddy YVM, Park TJ, Park J, Park JP. Nanozyme-assisted molecularly imprinted polymer-based indirect competitive ELISA for the detection of marine biotoxin. Biosens Bioelectron 2024; 255:116269. [PMID: 38579624 DOI: 10.1016/j.bios.2024.116269] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2024] [Revised: 03/21/2024] [Accepted: 04/01/2024] [Indexed: 04/07/2024]
Abstract
Saxitoxin (STX), which is produced by certain dinoflagellate species, is a type of paralytic shellfish poisoning toxin that poses a serious threat to human health and the environment. Therefore, developing a technology for the convenient and cost-effective detection of STX is imperative. In this study, we developed an affinity peptide-imprinted polymer-based indirect competitive ELISA (ic-ELISA) without using enzyme-toxin conjugates. AuNP/Co3O4@Mg/Al cLDH was synthesized by calcining AuNP/ZIF-67@Mg/Al LDH, which was obtained by combining AuNPs, ZIF-67, and flower-like Mg/Al LDH. This synthesized nanozyme exhibited high catalytic activity (Km = 0.24 mM for TMB and 132.5 mM for H2O2). The affinity peptide-imprinted polymer (MIP) was imprinted with an STX-specific template peptide (STX MIP) on a multi-well microplate and then reacted with an STX-specific signal peptide (STX SP). The interaction between the STX SP and MIP was detected using a streptavidin-coated nanozyme (SA-AuNP/Co3O4@Mg/Al cLDH). The developed MIP-based ic-ELISA exhibited excellent selectivity and sensitivity, with a limit of detection of 3.17 ng/mL (equivalent: 0.317 μg/g). Furthermore, the system was validated using a commercial ELISA kit and mussel tissue samples, and it demonstrated a high STX recovery with a low coefficient of variation. These results imply that the developed ic-ELISA can be used to detect STX in real samples.
Collapse
Affiliation(s)
- Chae Hwan Cho
- Department of Food Science and Technology, GreenTech-Based Food Safety Research Group (BK21 Four), Chung-Ang University, Anseong, 17546, Republic of Korea
| | - Ji Hong Kim
- Department of Food Science and Technology, GreenTech-Based Food Safety Research Group (BK21 Four), Chung-Ang University, Anseong, 17546, Republic of Korea
| | - Navnath S Padalkar
- Department of Food Science and Technology, GreenTech-Based Food Safety Research Group (BK21 Four), Chung-Ang University, Anseong, 17546, Republic of Korea
| | - Y Veera Manohara Reddy
- Department of Chemistry, Sri Venkateswara College, University of Delhi, New Delhi, India
| | - Tae Jung Park
- Department of Chemistry, Institute of Interdisciplinary Convergence Research, Research Institute of Chem-Bio Diagnostic Technology, Chung-Ang University, 84 Heukseok-ro, Dongjak-gu, Seoul, 06974, Republic of Korea
| | - Jinyoung Park
- Department of Polymer Science & Engineering, Kyungpook National University, 80 Daehak-ro, Daegu, 41566, Republic of Korea
| | - Jong Pil Park
- Department of Food Science and Technology, GreenTech-Based Food Safety Research Group (BK21 Four), Chung-Ang University, Anseong, 17546, Republic of Korea.
| |
Collapse
|
6
|
Sittihakote N, Danvirutai P, Anutrakulchai S, Tuantranont A, Srichan C. Empowering an Acute Kidney Injury 3D Graphene-Based Sensor Using Extreme Learning Machine. ACS OMEGA 2024; 9:21276-21286. [PMID: 38764614 PMCID: PMC11097169 DOI: 10.1021/acsomega.4c01315] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/12/2024] [Revised: 04/18/2024] [Accepted: 04/23/2024] [Indexed: 05/21/2024]
Abstract
This study reports on the application of an extreme learning machine (ELM) in near-real-time kidney monitoring via urine neutrophil gelatinase-associated lipocalin (NGAL) detection with a 3D graphene electrode. This integration marks the first instance of combining a graphene-based electrode with machine learning to enhance the NGAL detection accuracy, building on our group's 2020 research. The methodology involves two key components: a graphene electrode functionalized with a lipocalin-2 antibody for NGAL detection and the ELM application for improved prediction accuracy by using urine analysis data. The results show a significant 15% increase in the area under the curve (AUC) for NGAL determination, with error reduction from ±6 to 0.54 ng/mL within a linear range of 2.7-140 ng/mL. The ELM also lowered the detection limit from 14.8 to 0.89 ng/mL and increased accuracy, precision, sensitivity, specificity, and F1 score for AKI prediction by 8.89, 30.69, 6.78, 9.94, and 19.07%, respectively. These findings underscore the efficacy of simple neural networks in enhancing graphene-based electrochemical sensors for AKI biomarkers. ELM was chosen for its optimal performance-resource balance, with a comparative analysis of ELM, support vector machines, multilayer perceptron, and random forest algorithms also included. This research suggests the potential for miniaturizing AI-enhanced sensors for practical applications.
Collapse
Affiliation(s)
- Netnapa Sittihakote
- Faculty
of Engineering, Biomedical Engineering, Khon Kaen University, Nai Mueang 40002, Khon Kaen, Thailand
| | - Pobporn Danvirutai
- Faculty
of Engineering, Computer Engineering, Khon
Kaen University, Nai Mueang 40002, Khon Kaen, Thailand
| | - Sirirat Anutrakulchai
- Faculty
of Medicine, Khon Kaen University, Nai Mueang 40002, Khon Kaen, Thailand
- Chronic
Kidney Disease Prevention in the Northeast of Thailand, Khon Kaen University, 123 Khon Kaen University, Nai Mueang 40002, Khon Kaen, Thailand
| | - Adisorn Tuantranont
- National
Science and Technology Development Agency, 111 Thailand Science Park, Khlong Luang 12120, Pathum Thani, Thailand
| | - Chavis Srichan
- Faculty
of Engineering, Biomedical Engineering, Khon Kaen University, Nai Mueang 40002, Khon Kaen, Thailand
- Faculty
of Engineering, Computer Engineering, Khon
Kaen University, Nai Mueang 40002, Khon Kaen, Thailand
| |
Collapse
|
7
|
Yang Z, Guo J, Wang L, Zhang J, Ding L, Liu H, Yu X. Nanozyme-Enhanced Electrochemical Biosensors: Mechanisms and Applications. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024; 20:e2307815. [PMID: 37985947 DOI: 10.1002/smll.202307815] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Revised: 10/22/2023] [Indexed: 11/22/2023]
Abstract
Nanozymes, as innovative materials, have demonstrated remarkable potential in the field of electrochemical biosensors. This article provides an overview of the mechanisms and extensive practical applications of nanozymes in electrochemical biosensors. First, the definition and characteristics of nanozymes are introduced, emphasizing their significant role in constructing efficient sensors. Subsequently, several common categories of nanozyme materials are delved into, including metal-based, carbon-based, metal-organic framework, and layered double hydroxide nanostructures, discussing their applications in electrochemical biosensors. Regarding their mechanisms, two key roles of nanozymes are particularly focused in electrochemical biosensors: selective enhancement and signal amplification, which crucially support the enhancement of sensor performance. In terms of practical applications, the widespread use of nanozyme-based electrochemical biosensors are showcased in various domains. From detecting biomolecules, pollutants, nucleic acids, proteins, to cells, providing robust means for high-sensitivity detection. Furthermore, insights into the future development of nanozyme-based electrochemical biosensors is provided, encompassing improvements and optimizations of nanozyme materials, innovative sensor design and integration, and the expansion of application fields through interdisciplinary collaboration. In conclusion, this article systematically presents the mechanisms and applications of nanozymes in electrochemical biosensors, offering valuable references and prospects for research and development in this field.
Collapse
Affiliation(s)
- Zhongwei Yang
- Institute for Advanced Interdisciplinary Research (iAIR), School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, P. R. China
| | - Jiawei Guo
- Institute for Advanced Interdisciplinary Research (iAIR), School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, P. R. China
| | - Longwei Wang
- CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety & CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology of China, University of Chinese Academy of Science, Beijing, 100190, P. R. China
| | - Jian Zhang
- Division of Systems and Synthetic Biology, Department of Life Sciences, Chalmers University of Technology, Göteborg, 41296, Sweden
| | - Longhua Ding
- Institute for Advanced Interdisciplinary Research (iAIR), School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, P. R. China
| | - Hong Liu
- Institute for Advanced Interdisciplinary Research (iAIR), School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, P. R. China
- State Key Laboratory of Crystal Materials, Shandong University, Jinan, 250100, P. R. China
| | - Xin Yu
- Institute for Advanced Interdisciplinary Research (iAIR), School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, P. R. China
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE, Qingdao University of Science and Technology, Qingdao, 266042, P. R. China
| |
Collapse
|
8
|
Sitkov N, Ryabko A, Moshnikov V, Aleshin A, Kaplun D, Zimina T. Hybrid Impedimetric Biosensors for Express Protein Markers Detection. MICROMACHINES 2024; 15:181. [PMID: 38398911 PMCID: PMC10890403 DOI: 10.3390/mi15020181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/31/2023] [Revised: 01/22/2024] [Accepted: 01/23/2024] [Indexed: 02/25/2024]
Abstract
Impedimetric biosensors represent a powerful and promising tool for studying and monitoring biological processes associated with proteins and can contribute to the development of new approaches in the diagnosis and treatment of diseases. The basic principles, analytical methods, and applications of hybrid impedimetric biosensors for express protein detection in biological fluids are described. The advantages of this type of biosensors, such as simplicity and speed of operation, sensitivity and selectivity of analysis, cost-effectiveness, and an ability to be integrated into hybrid microfluidic systems, are demonstrated. Current challenges and development prospects in this area are analyzed. They include (a) the selection of materials for electrodes and formation of nanostructures on their surface; (b) the development of efficient methods for biorecognition elements' deposition on the electrodes' surface, providing the specificity and sensitivity of biosensing; (c) the reducing of nonspecific binding and interference, which could affect specificity; (d) adapting biosensors to real samples and conditions of operation; (e) expanding the range of detected proteins; and, finally, (f) the development of biosensor integration into large microanalytical system technologies. This review could be useful for researchers working in the field of impedimetric biosensors for protein detection, as well as for those interested in the application of this type of biosensor in biomedical diagnostics.
Collapse
Affiliation(s)
- Nikita Sitkov
- Department of Micro and Nanoelectronics, Saint Petersburg Electrotechnical University “LETI”, 197022 Saint Petersburg, Russia; (V.M.); (T.Z.)
- Engineering Centre for Microtechnology and Diagnostics, Saint Petersburg Electrotechnical University “LETI”, 197022 Saint Petersburg, Russia
| | - Andrey Ryabko
- Laboratory of Nonequilibrium Processes in Semiconductors, Ioffe Institute, 26 Politekhnicheskaya, 194021 Saint Petersburg, Russia;
| | - Vyacheslav Moshnikov
- Department of Micro and Nanoelectronics, Saint Petersburg Electrotechnical University “LETI”, 197022 Saint Petersburg, Russia; (V.M.); (T.Z.)
| | - Andrey Aleshin
- Laboratory of Nonequilibrium Processes in Semiconductors, Ioffe Institute, 26 Politekhnicheskaya, 194021 Saint Petersburg, Russia;
| | - Dmitry Kaplun
- Artificial Intelligence Research Institute, China University of Mining and Technology, 1 Daxue Road, Xuzhou 221116, China;
- Department of Automation and Control Processes, Saint Petersburg Electrotechnical University “LETI”, 197022 Saint Petersburg, Russia
| | - Tatiana Zimina
- Department of Micro and Nanoelectronics, Saint Petersburg Electrotechnical University “LETI”, 197022 Saint Petersburg, Russia; (V.M.); (T.Z.)
- Engineering Centre for Microtechnology and Diagnostics, Saint Petersburg Electrotechnical University “LETI”, 197022 Saint Petersburg, Russia
| |
Collapse
|
9
|
Fadaie M, Dianat-Moghadam H, Ghafouri E, Naderi S, Darvishali MH, Ghovvati M, Khanahmad H, Boshtam M, Makvandi P. Unraveling the potential of M13 phages in biomedicine: Advancing drug nanodelivery and gene therapy. ENVIRONMENTAL RESEARCH 2023; 238:117132. [PMID: 37714365 DOI: 10.1016/j.envres.2023.117132] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Revised: 09/05/2023] [Accepted: 09/12/2023] [Indexed: 09/17/2023]
Abstract
M13 phages possessing filamentous phage genomes offer the benefits of selective display of molecular moieties and delivery of therapeutic agent payloads with a tolerable safety profile. M13 phage-displayed technology for resembling antigen portions led to the discovery of mimetic epitopes that applied to antibody-based therapy and could be useful in the design of anticancer vaccines. To date, the excremental experiences have engaged the M13 phage in the development of innovative biosensors for detecting biospecies, biomolecules, and human cells with an acceptable limit of detection. Addressing the emergence of antibiotic-resistant bacteria, M13 phages are potent for packaging the programmed gene editing tools, such as CRISPR/Cas, to target multiple antimicrobial genes. Moreover, their display potential in combination with nanoparticles inspires new approaches for engineering targeted theragnostic platforms targeting multiple cellular biomarkers in vivo. In this review, we present the available data on optimizing the use of bacteriophages with a focus on the to date experiences with M13 phages, either as monoagent or as part of combination regimens in the practices of biosensors, vaccines, bactericidal, modeling of specific antigen epitopes, and phage-guided nanoparticles for drug delivery systems. Despite increasing research interest, a deep understanding of the underlying biological and genetic behaviors of M13 phages is needed to enable the full potential of these bioagents in biomedicine, as discussed here. We also discuss some of the challenges that have thus far limited the development and practical marketing of M13 phages.
Collapse
Affiliation(s)
- Mahmood Fadaie
- Department of Genetics and Molecular Biology, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Hassan Dianat-Moghadam
- Department of Genetics and Molecular Biology, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran; Pediatric Inherited Diseases Research Center, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Elham Ghafouri
- Department of Genetics and Molecular Biology, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Shamsi Naderi
- Department of Genetics and Molecular Biology, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Mohammad Hossein Darvishali
- Department of Genetics and Molecular Biology, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Mahsa Ghovvati
- Department of Radiological Sciences, David Geffen School of Medicine, University of California - Los Angeles, Los Angeles, CA 90095, USA
| | - Hossein Khanahmad
- Department of Genetics and Molecular Biology, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran.
| | - Maryam Boshtam
- Isfahan Cardiovascular Research Center, Cardiovascular Research Institute, Isfahan University of Medical Sciences, Isfahan, Iran.
| | - Pooyan Makvandi
- The Quzhou Affiliated Hospital of Wenzhou Medical University, Quzhou People's Hospital, Quzhou, 324000, Zhejiang, China.
| |
Collapse
|
10
|
Divya, Darshna, Sammi A, Chandra P. Design and development of opto-electrochemical biosensing devices for diagnosing chronic kidney disease. Biotechnol Bioeng 2023; 120:3116-3136. [PMID: 37439074 DOI: 10.1002/bit.28490] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Revised: 06/03/2023] [Accepted: 06/27/2023] [Indexed: 07/14/2023]
Abstract
Chronic kidney disease (CKD) is emerging as one of the major causes of the increase in mortality rate and is expected to become 5th major cause by 2050. Many studies have shown that it is majorly related to various risk factors, and thus becoming one of the major health issues around the globe. Early detection of renal disease lowers the overall burden of disease by preventing individuals from developing kidney impairment. Therefore, diagnosis and prevention of CKD are becoming the major challenges, and in this situation, biosensors have emerged as one of the best possible solutions. Biosensors are becoming one of the preferred choices for various diseases diagnosis as they provide simpler, cost-effective and precise methods for onsite detection. In this review, we have tried to discuss the globally developed biosensors for the detection of CKD, focusing on their design, pattern, and applicability in real samples. Two major classifications of biosensors based on transduction systems, that is, optical and electrochemical, for kidney disease have been discussed in detail. Also, the major focus is given to clinical biomarkers such as albumin, creatinine, and others related to kidney dysfunction. Furthermore, the globally developed sensors for the detection of CKD are discussed in tabulated form comparing their analytical performance, response time, specificity as well as performance in biological fluids.
Collapse
Affiliation(s)
- Divya
- Laboratory of Bio-Physio Sensors and Nanobioengineering School of Biochemical Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi, Uttar Pradesh, India
| | - Darshna
- Laboratory of Bio-Physio Sensors and Nanobioengineering School of Biochemical Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi, Uttar Pradesh, India
| | - Aditi Sammi
- Laboratory of Bio-Physio Sensors and Nanobioengineering School of Biochemical Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi, Uttar Pradesh, India
| | - Pranjal Chandra
- Laboratory of Bio-Physio Sensors and Nanobioengineering School of Biochemical Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi, Uttar Pradesh, India
| |
Collapse
|
11
|
Xiao Y, Zhang T, Zhang H. Recent advances in the peptide-based biosensor designs. Colloids Surf B Biointerfaces 2023; 231:113559. [PMID: 37738870 DOI: 10.1016/j.colsurfb.2023.113559] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Revised: 09/09/2023] [Accepted: 09/17/2023] [Indexed: 09/24/2023]
Abstract
Biosensors have rapidly emerged as a high-sensitivity and convenient detection method. Among various types of biosensors, optical and electrochemical are the most commonly used. Conventionally, antibodies have been employed to ensure specific interaction between the transmission material and analytes. However, there has been increasing recognition of peptides as a promising recognition element for biosensor development in recent years. The use of peptides as recognition elements provides high level of specificity, sensitivity, and stability for the detection process. The combination of peptide designs and optical or electrochemical detection methods has significantly improved biosensor efficacy. These advancements present opportunities for developing biosensors with diverse functions that can be used to lay a strong scientific foundation for the development of personalized medicine and various other fields. This paper reviews the recent advancements in the development and application of peptide-based optical and electrochemical biosensors, as well as their prospects as a sensor type.
Collapse
Affiliation(s)
- Yue Xiao
- Department of Biotechnology, College of Life Science and Technology, Huazhong University of Science and Technology, MOE Key Laboratory of Molecular Biophysics, Wuhan 430074, China
| | - Ting Zhang
- Department of Biotechnology, College of Life Science and Technology, Huazhong University of Science and Technology, MOE Key Laboratory of Molecular Biophysics, Wuhan 430074, China
| | - Houjin Zhang
- Department of Biotechnology, College of Life Science and Technology, Huazhong University of Science and Technology, MOE Key Laboratory of Molecular Biophysics, Wuhan 430074, China.
| |
Collapse
|
12
|
Kim JH, Jeong HS, Hwang J, Kweon DH, Choi CH, Park JP. Affinity Peptide-Tethered Suspension Hydrogel Sensor for Selective and Sensitive Detection of Influenza Virus. ACS APPLIED MATERIALS & INTERFACES 2023. [PMID: 37903089 DOI: 10.1021/acsami.3c14470] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/01/2023]
Abstract
Influenza viruses are known to cause pandemic flu outbreaks through both inter-human and animal-to-human transmissions. Therefore, the rapid and accurate detection of such pathogenic viruses is crucial for effective pandemic control. Here, we introduce a novel sensor based on affinity peptide-immobilized hydrogel microspheres for the selective detection of influenza A virus (IAV) H3N2. To enhance the binding affinity performance, we identified novel affinity peptides using phage display and further optimized their design. The functional hydrogel microspheres were constructed using the drop microfluidic technique, employing a structure composed of natural (chitosan) and synthetic (poly(ethylene glycol) diacrylate and PEG 6 kDa) polymers with the activation of azadibenzocyclooctyne for the subsequent click chemistry reaction. The binding peptide-immobilized hydrogel microsphere (BP-Hyd) was characterized by field emission scanning electron microscopy, X-ray photoelectron spectroscopy, and Fourier transform infrared spectroscopy and exhibited selective detection capability for the IAV H3N2. To capture the detected IAV H3N2, a Cy3-labeled IAV hemagglutinin antibody was utilized. By incorporating the affinity peptide with hydrogel microspheres, we achieved quantitative and selective detection of IAV H3N2 with a detection limit of 1.887 PFU mL-1. Furthermore, the developed suspension sensor exhibited excellent reproducibility and showed reusability potential. Our results revealed that the BP-Hyd-based fluorescence sensor platform could be feasibly employed to detect other pathogens because the virus-binding peptides can be easily replaced with other peptides through phage display, enabling selective and sensitive binding to different targets.
Collapse
Affiliation(s)
- Ji Hong Kim
- Department of Food Science and Technology, Chung-Ang University, Anseong 17546, Republic of Korea
| | - Hye-Seon Jeong
- School of Chemical Engineering, Yeungnam University, 280 Daehak-ro, Gyeongsan, Gyeongsangbuk-do 38541, Republic of Korea
| | - Jaehyeon Hwang
- Department of Integrative Biotechnology, Sungkyunkwan University, Suwon 16419, Republic of Korea
| | - Dae-Hyuk Kweon
- Department of Integrative Biotechnology, Sungkyunkwan University, Suwon 16419, Republic of Korea
| | - Chang-Hyung Choi
- School of Chemical Engineering, Yeungnam University, 280 Daehak-ro, Gyeongsan, Gyeongsangbuk-do 38541, Republic of Korea
| | - Jong Pil Park
- Department of Food Science and Technology, Chung-Ang University, Anseong 17546, Republic of Korea
| |
Collapse
|
13
|
Raju CV, Manohara Reddy YV, Cho CH, Shin HH, Park TJ, Park JP. Highly sensitive electrochemical peptide-based biosensor for marine biotoxin detection using a bimetallic platinum and ruthenium nanoparticle-tethered metal-organic framework modified electrode. Food Chem 2023; 428:136811. [PMID: 37423105 DOI: 10.1016/j.foodchem.2023.136811] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Revised: 06/10/2023] [Accepted: 07/03/2023] [Indexed: 07/11/2023]
Abstract
Saxitoxin (STX) is a highly toxic small-molecule cyanotoxin that is water-soluble, stable in acidic media, and thermostable. STX is hazardous to human health and the environment in ocean, thus it is an important to detect it at very low concentrations. Herein, we developed an electrochemical peptide-based biosensor for the trace detection of STX in different sample matrix utilizing differential pulse voltammetry (DPV) signal. We synthesized the nanocomposite of zeolitic imidazolate framework-67 (ZIF-67) decorated bimetallic platinum (Pt) and ruthenium (Ru) nanoparticles (Pt-Ru@C/ZIF-67) using impregnation method. The nanocomposite modified with screen-printed electrode (SPE) was subsequently used to detect STX in the range of 1-1,000 ng mL-1, with a detection limit (LOD) of 26.7 pg mL-1. The developed peptide-based biosensor is highly selective and sensitive towards STX detection, thus it represents a promising strategy for the development of novel portable bioassay for monitoring various hazardous molecules in aquatic food chains.
Collapse
Affiliation(s)
- Chikkili Venkateswara Raju
- Basic Research Laboratory, Department of Food Science and Technology, Chung-Ang University, Anseong 17546, Republic of Korea
| | - Y Veera Manohara Reddy
- Basic Research Laboratory, Department of Food Science and Technology, Chung-Ang University, Anseong 17546, Republic of Korea
| | - Chae Hwan Cho
- Basic Research Laboratory, Department of Food Science and Technology, Chung-Ang University, Anseong 17546, Republic of Korea
| | - Hyeon Ho Shin
- Library of Marine Samples, Korea Institute of Ocean Science & Technology, Geoje 53201, Republic of Korea
| | - Tae Jung Park
- Department of Chemistry, Institute of Interdisciplinary Convergence Research, Research Institute of Chem-Bio Diagnostic Technology, Chung-Ang University, 84 Heukseok-ro, Dongjak-gu, Seoul 06974, Republic of Korea
| | - Jong Pil Park
- Basic Research Laboratory, Department of Food Science and Technology, Chung-Ang University, Anseong 17546, Republic of Korea.
| |
Collapse
|
14
|
Chang C, Guo W, Yu X, Guo C, Zhou N, Guo X, Huang RL, Li Q, Zhu Y. Engineered M13 phage as a novel therapeutic bionanomaterial for clinical applications: From tissue regeneration to cancer therapy. Mater Today Bio 2023; 20:100612. [PMID: 37063776 PMCID: PMC10102448 DOI: 10.1016/j.mtbio.2023.100612] [Citation(s) in RCA: 21] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2023] [Revised: 03/12/2023] [Accepted: 03/15/2023] [Indexed: 04/03/2023] Open
Abstract
Bacteriophages (phages) are nanostructured viruses with highly selective antibacterial properties that have gained attention beyond eliminating bacteria. Specifically, M13 phages are filamentous phages that have recently been studied in various aspects of nanomedicine due to their biological advantages and more compliant engineering capabilities over other phages. Having nanofiber-like morphology, M13 phages can reach varied target sites and self-assemble into multidimensional scaffolds in a relatively safe and stable way. In addition, genetic modification of the coat proteins enables specific display of peptides and antibodies on the phages, allowing for precise and individualized medicine. M13 phages have also been subjected to novel engineering approaches, including phage-based bionanomaterial engineering and phage-directed nanomaterial combinations that enhance the bionanomaterial properties of M13 phages. In view of these features, researchers have been able to utilize M13 phages for therapeutic applications such as drug delivery, biodetection, tissue regeneration, and targeted cancer therapy. In particular, M13 phages have been utilized as a novel bionanomaterial for precisely mimicking natural tissue environment in order to overcome the shortage in tissue and organ donors. Hence, in this review, we address the recent studies and advances of using M13 phages in the field of nanomedicine as therapeutic agents based upon their characteristics as novel bionanomaterial with biomolecules displayed. This paper also emphasizes the novel engineering approach that enhances M13 phage's bionanomaterial capabilities. Current limitations and future approaches are also discussed to provide insight in further progress for M13 phage-based clinical applications.
Collapse
Affiliation(s)
- Cheng Chang
- School of Global Health, Chinese Centre for Tropical Diseases Research, Shanghai Jiao Tong University School of Medicine, One Health Center, Shanghai Jiao Tong University-The University of Edinburgh, Shanghai, 200025, China
| | - Wennan Guo
- School of Global Health, Chinese Centre for Tropical Diseases Research, Shanghai Jiao Tong University School of Medicine, One Health Center, Shanghai Jiao Tong University-The University of Edinburgh, Shanghai, 200025, China
| | - Xinbo Yu
- Second Dental Center, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 201999, China
| | - Chaoyi Guo
- School of Global Health, Chinese Centre for Tropical Diseases Research, Shanghai Jiao Tong University School of Medicine, One Health Center, Shanghai Jiao Tong University-The University of Edinburgh, Shanghai, 200025, China
| | - Nan Zhou
- School of Global Health, Chinese Centre for Tropical Diseases Research, Shanghai Jiao Tong University School of Medicine, One Health Center, Shanghai Jiao Tong University-The University of Edinburgh, Shanghai, 200025, China
| | - Xiaokui Guo
- School of Global Health, Chinese Centre for Tropical Diseases Research, Shanghai Jiao Tong University School of Medicine, One Health Center, Shanghai Jiao Tong University-The University of Edinburgh, Shanghai, 200025, China
| | - Ru-Lin Huang
- Department of Plastic and Reconstructive Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, China
- Corresponding author.
| | - Qingtian Li
- Department of Laboratory Medicine, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China
- Corresponding author.
| | - Yongzhang Zhu
- School of Global Health, Chinese Centre for Tropical Diseases Research, Shanghai Jiao Tong University School of Medicine, One Health Center, Shanghai Jiao Tong University-The University of Edinburgh, Shanghai, 200025, China
- Corresponding author.
| |
Collapse
|
15
|
Cho CH, Park CY, Chun HS, Park TJ, Park JP. Antibody-free and selective detection of okadaic acid using an affinity peptide-based indirect assay. Food Chem 2023; 422:136243. [PMID: 37141762 DOI: 10.1016/j.foodchem.2023.136243] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2023] [Revised: 04/19/2023] [Accepted: 04/24/2023] [Indexed: 05/06/2023]
Abstract
Okadaic acid (OA) is a type of marine biotoxin produced by some species of dinoflagellates in marine environments. Consumption of shellfish contaminated with OA can cause diarrhetic shellfish poisoning (DSP) in humans with symptoms that typically include abdominal pain, diarrhea and vomiting. In this study, we developed an affinity peptide-based direct competition enzyme-linked immunosorbent assay (dc-ELISA) for the detection of OA in real samples. The OA-specific peptide was successfully identified via M13 biopanning and a series of peptides were chemically synthesized and characterized their recognition activities. The dc-ELISA system showed good sensitivity and selectivity with a half-maximal inhibitory concentration (IC50) of 148.7 ng/mL and a limit of detection (LOD) of 5.41 ng/mL (equivalent, 21.52 ng/g). Moreover, the effectiveness of the developed dc-ELISA was validated using OA-spiked shellfish samples, and the developed dc-ELISA showed a high recovery rate. These results suggest that the affinity peptide-based dc-ELISA can be a promising tool for detecting OA in shellfish samples.
Collapse
Affiliation(s)
- Chae Hwan Cho
- Department of Food Science and Technology, Chung-Ang University, Anseong 17546, Republic of Korea
| | - Chan Yeong Park
- Department of Chemistry, Institute of Interdisciplinary Convergence Research, Research Institute of Chem-Bio Diagnostic Technology, Chung-Ang University, 84 Heukseok-ro, Dongjak-gu, Seoul 06974, Republic of Korea
| | - Hyang Sook Chun
- Department of Food Science and Technology, Chung-Ang University, Anseong 17546, Republic of Korea
| | - Tae Jung Park
- Department of Chemistry, Institute of Interdisciplinary Convergence Research, Research Institute of Chem-Bio Diagnostic Technology, Chung-Ang University, 84 Heukseok-ro, Dongjak-gu, Seoul 06974, Republic of Korea.
| | - Jong Pil Park
- Department of Food Science and Technology, Chung-Ang University, Anseong 17546, Republic of Korea.
| |
Collapse
|
16
|
Kim JH, Shin JH, Park B, Cho CH, Huh YS, Choi CH, Park JP. Harnessing protein sensing ability of electrochemical biosensors via a controlled peptide receptor-electrode interface. J Nanobiotechnology 2023; 21:100. [PMID: 36944950 PMCID: PMC10029155 DOI: 10.1186/s12951-023-01843-0] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2022] [Accepted: 03/06/2023] [Indexed: 03/23/2023] Open
Abstract
BACKGROUND Cathepsin B, a cysteine protease, is considered a potential biomarker for early diagnosis of cancer and inflammatory bowel diseases. Therefore, more feasible and effective diagnostic method may be beneficial for monitoring of cancer or related diseases. RESULTS A phage-display library was biopanned against biotinylated cathepsin B to identify a high-affinity peptide with the sequence WDMWPSMDWKAE. The identified peptide-displaying phage clones and phage-free synthetic peptides were characterized using enzyme-linked immunosorbent assays (ELISAs) and electrochemical analyses (impedance spectroscopy, cyclic voltammetry, and square wave voltammetry). Feasibilities of phage-on-a-sensor, peptide-on-a-sensor, and peptide-on-a-AuNPs/MXene sensor were evaluated. The limit of detection and binding affinity values of the peptide-on-a-AuNPs/MXene sensor interface were two to four times lower than those of the two other sensors, indicating that the peptide-on-a-AuNPs/MXene sensor is more specific for cathepsin B (good recovery (86-102%) and %RSD (< 11%) with clinical samples, and can distinguish different stages of Crohn's disease. Furthermore, the concentration of cathepsin B measured by our sensor showed a good correlation with those estimated by the commercially available ELISA kit. CONCLUSION In summary, screening and rational design of high-affinity peptides specific to cathepsin B for developing peptide-based electrochemical biosensors is reported for the first time. This study could promote the development of alternative antibody-free detection methods for clinical assays to test inflammatory bowel disease and other diseases.
Collapse
Affiliation(s)
- Ji Hong Kim
- Basic Research Laboratory, Department of Food Science and Technology, Chung-Ang University, Anseong, 17546, Republic of Korea
| | - Jae Hwan Shin
- Basic Research Laboratory, Department of Food Science and Technology, Chung-Ang University, Anseong, 17546, Republic of Korea
| | - Bumjun Park
- NanoBio High-Tech Materials Research Center, Department of Biological Sciences and Bioengineering, Inha University, 100 Inha-Ro, Incheon, 22212, Republic of Korea
| | - Chae Hwan Cho
- Basic Research Laboratory, Department of Food Science and Technology, Chung-Ang University, Anseong, 17546, Republic of Korea
| | - Yun Suk Huh
- NanoBio High-Tech Materials Research Center, Department of Biological Sciences and Bioengineering, Inha University, 100 Inha-Ro, Incheon, 22212, Republic of Korea
| | - Chang-Hyung Choi
- School of Chemical Engineering, Yeungnam University, 280 Daehak-ro, Gyeongsan, Gyeongbuk, 38541, Republic of Korea
| | - Jong Pil Park
- Basic Research Laboratory, Department of Food Science and Technology, Chung-Ang University, Anseong, 17546, Republic of Korea.
| |
Collapse
|
17
|
Zhang Q, Li Y, Hu Q, Xie R, Zhou W, Liu X, Wang Y. Smartphone surface plasmon resonance imaging for the simultaneous and sensitive detection of acute kidney injury biomarkers with noninvasive urinalysis. LAB ON A CHIP 2022; 22:4941-4949. [PMID: 36411971 DOI: 10.1039/d2lc00417h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
A surface plasmon resonance imaging (SPRi) platform integrated with a smartphone was constructed for the simultaneous and sensitive detection of acute kidney injury (AKI) biomarkers. The smartphone SPRi platform was developed without the requirement of additional light and power sources. The LED flash of the smartphone was used as the light source for the excitation of surface plasmon resonance of a gold sensor chip based on the Kretschmann configuration, while the reflected light was collected by the camera of the smartphone. This smartphone SPRi system was conveniently fabricated by 3D printing and showed a sensitivity of 1.78 × 10-5 refractive index unit (RIU). In addition, based on a magnetic nanoparticle-enhanced sandwich immunoassay, the smartphone SPRi system with a gold array chip was employed for the detection of multiple AKI biomarkers, with a low limit of detection (LOD) of 0.19 ng ml-1, 0.51 ng ml-1 and 0.7 ng ml-1 for the simultaneous detection of neutrophil gelatinase-associated lipocalin (NGAL), interleukin-18 (IL-18) and retinol-binding protein (RBP) in urine, respectively. The biosensors demonstrated high specificity and sensitivity for the simultaneous detection of multiple AKI biomarkers in PBST and urine. The smartphone SPRi system provided a portable and cost-effective platform for point-of-care diagnosis, in-field healthcare and environmental monitoring.
Collapse
Affiliation(s)
- Qingwen Zhang
- School of Ophthalmology and Optometry, Eye Hospital, School of Biomedical Engineering, Wenzhou Medical University, Wenzhou, 325001 China.
- Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, 325001 China.
| | - Yang Li
- School of Ophthalmology and Optometry, Eye Hospital, School of Biomedical Engineering, Wenzhou Medical University, Wenzhou, 325001 China.
- The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou, 325000 China
| | - Qianqian Hu
- Beijing Chaoyang District Ecological and Environmental Monitoring Center, Beijing, 100123 China
| | - Ruifeng Xie
- Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, 325001 China.
| | - Wenjing Zhou
- School of Ophthalmology and Optometry, Eye Hospital, School of Biomedical Engineering, Wenzhou Medical University, Wenzhou, 325001 China.
| | - Xiaohu Liu
- School of Ophthalmology and Optometry, Eye Hospital, School of Biomedical Engineering, Wenzhou Medical University, Wenzhou, 325001 China.
| | - Yi Wang
- School of Ophthalmology and Optometry, Eye Hospital, School of Biomedical Engineering, Wenzhou Medical University, Wenzhou, 325001 China.
- Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, 325001 China.
| |
Collapse
|
18
|
Chamorro-Garcia A, Parolo C, Ortega G, Idili A, Green J, Ricci F, Plaxco KW. The sequestration mechanism as a generalizable approach to improve the sensitivity of biosensors and bioassays. Chem Sci 2022; 13:12219-12228. [PMID: 36349092 PMCID: PMC9601244 DOI: 10.1039/d2sc03901j] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2022] [Accepted: 09/16/2022] [Indexed: 07/25/2023] Open
Abstract
Biosensors and bioassays, both of which employ proteins and nucleic acids to detect specific molecular targets, have seen significant applications in both biomedical research and clinical practice. This success is largely due to the extraordinary versatility, affinity, and specificity of biomolecular recognition. Nevertheless, these receptors suffer from an inherent limitation: single, saturable binding sites exhibit a hyperbolic relationship (the "Langmuir isotherm") between target concentration and receptor occupancy, which in turn limits the sensitivity of these technologies to small variations in target concentration. To overcome this and generate more responsive biosensors and bioassays, here we have used the sequestration mechanism to improve the steepness of the input/output curves of several bioanalytical methods. As our test bed for this we employed sensors and assays against neutrophil gelatinase-associated lipocalin (NGAL), a kidney biomarker for which enhanced sensitivity will improve the monitoring of kidney injury. Specifically, by introducing sequestration we have improved the responsiveness of an electrochemical aptamer based (EAB) biosensor, and two bioassays, a paper-based "dipstick" assay and an enzyme-linked immunosorbent assay (ELISA). Doing so we have narrowed the dynamic range of these sensors and assays several-fold, thus enhancing their ability to measure small changes in target concentration. Given that introducing sequestration requires only the addition of the appropriate concentration of a high-affinity "depletant," the mechanism appears simple and easily adaptable to tuning the binding properties of the receptors employed in a wide range of biosensors and bioassays.
Collapse
Affiliation(s)
- Alejandro Chamorro-Garcia
- Department of Chemistry and Biochemistry University of California Santa Barbara (UCSB) Santa Barbara CA 93106 USA
- Dipartimento di Scienze e Tecnologie Chimiche, University of Rome, Tor Vergata, Via della Ricerca Scientifica 00133 Rome Italy
| | - Claudio Parolo
- ISGlobal-Barcelona Institute for Global Health Carrer del Rosselló 132 08036 Barcelona Spain
| | - Gabriel Ortega
- Ikerbasque, Basque Foundation for Science 48013 Bilbao Spain
- Precision Medicine and Metabolism Laboratory, CIC BioGUNE, Basque Research and Technology Alliance, Parque Tecnológico de Bizkaia 48160 Derio Spain
| | - Andrea Idili
- Dipartimento di Scienze e Tecnologie Chimiche, University of Rome, Tor Vergata, Via della Ricerca Scientifica 00133 Rome Italy
| | - Joshua Green
- Department of Chemistry and Biochemistry University of California Santa Barbara (UCSB) Santa Barbara CA 93106 USA
| | - Francesco Ricci
- Dipartimento di Scienze e Tecnologie Chimiche, University of Rome, Tor Vergata, Via della Ricerca Scientifica 00133 Rome Italy
| | - Kevin W Plaxco
- Department of Chemistry and Biochemistry University of California Santa Barbara (UCSB) Santa Barbara CA 93106 USA
| |
Collapse
|
19
|
Affinity Peptide-based Electrochemical Biosensor for the Highly Sensitive Detection of Bovine Rotavirus. BIOTECHNOL BIOPROC E 2022; 27:607-614. [PMID: 35755619 PMCID: PMC9209633 DOI: 10.1007/s12257-022-0044-6] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2022] [Revised: 03/09/2022] [Accepted: 03/10/2022] [Indexed: 11/02/2022]
Abstract
Bovine diarrhea is a major concern in the global bovine industry because it can cause significant financial damage. Of the many potential infectious agents that can lead to bovine diarrhea, bovine rotavirus (BRV) is a particular problem due to its high transmissibility and infectivity. Therefore, it is important to prevent the proliferation of BRV using an early detection system. This study developed an affinity peptide-based electrochemical method for use as a rapid detection system for BRV. A BRV-specific peptide was identified via the phage display technique and chemically synthesized. The synthetic peptide was immobilized on a gold electrode through thiol-gold interactions. The performance of the BRV specific binding peptides was evaluated using square wave voltammetry. The developed detection system exhibited a low detection limit (5 copies/mL) and limit of quantitation (2.14 × 102 copies/mL), indicating that it is a promising sensor platform for the monitoring of BRV.
Collapse
|
20
|
Das M, Chakraborty T, Yu Lin C, Fong Lei K, Haur Kao C. Electrochemical detection of acute renal disease biomarker by Galinstan nanoparticles interfaced to bilayer polymeric structured dirhenium heptoxide film. Bioelectrochemistry 2022; 147:108194. [PMID: 35752029 DOI: 10.1016/j.bioelechem.2022.108194] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2022] [Revised: 06/14/2022] [Accepted: 06/15/2022] [Indexed: 11/02/2022]
Abstract
This work describes a facile fabrication of an efficient electrochemical sensor utilizing sonication-derived Galinstan nanoparticles (Galinstan NPs) interfaced to annealed dirhenium heptoxide (Re2O7) thin-film on Silicon (Si) for the quantitative detection of the most promising acute renal disease biomarker Neutrophil Gelatinase Associated Lipocalin (NGAL). Under optimized preconditions, the anti-NGAL antibodies were immobilized on the Galinstan NPs/Re2O7/Si electrode by carbodiimide crosslinking to detect NGAL. The composition, morphology, and structural properties of the electrode were elucidated by various physical characterizations. The sensor obtained a high sensitivity (0.018 µA-1ng-1ml-1, R2 = 0.99) in differential pulse voltammetry and a minimum detection limit (2.14 ng ml-1) in electrochemical impedance spectroscopy for a wide range of NGAL concentrations (25-650 ng ml-1) with high selectivity and stability. The intensified performance of the sensor was achieved by the summed-up electron transfer from the Re2O7 film to Galinstan NPs and Galinstan NPs to the electroactive reactants. Additionally, the outer 2D gallium oxide (Ga2O3) layer of Galinstan Nps enhanced the redox activities, whereas the metallic core contributed to the magnificent conductivity. The excellent recovery rates of the sensor for different concentrations of NGAL measured in commercial human serum by the standard addition method assured the feasibility of the sensor.
Collapse
Affiliation(s)
- Munmun Das
- Department of Electronic Engineering, Chang Gung University, 259 Wen-Hwa 1st Road, Kwei-Shan, Tao-Yuan 333, Taiwan, ROC
| | - Titisha Chakraborty
- Department of Electronic Engineering, Chang Gung University, 259 Wen-Hwa 1st Road, Kwei-Shan, Tao-Yuan 333, Taiwan, ROC
| | - Chan Yu Lin
- Kidney Research Center, Department of Nephrology, Chang Gung Memorial Hospital, No.5, Fuxing St., Guishan Dist., Taoyuan City 333, Taiwan ROC
| | - Kin Fong Lei
- Biomedical Engineering, Chang Gung University, Taoyuan, Taiwan
| | - Chyuan Haur Kao
- Department of Electronic Engineering, Chang Gung University, 259 Wen-Hwa 1st Road, Kwei-Shan, Tao-Yuan 333, Taiwan, ROC; Kidney Research Center, Department of Nephrology, Chang Gung Memorial Hospital, No.5, Fuxing St., Guishan Dist., Taoyuan City 333, Taiwan ROC; Department of Electronic Engineering, Ming Chi University of Technology, 284 Gungjuan Rd., Taishan Dist., New Taipei City 24301, Taiwan, ROC; Center for Green Technology, Chang Gung University, 259 Wen-Hwa 1st Road, Kwei-Shan, Tao-Yuan 333, Taiwan, ROC.
| |
Collapse
|
21
|
Manohara Reddy YV, Shin JH, Hwang J, Kweon DH, Choi CH, Park K, Kim SK, Madhavi G, Yi H, Park JP. Fine-tuning of MXene-nickel oxide-reduced graphene oxide nanocomposite bioelectrode: Sensor for the detection of influenza virus and viral protein. Biosens Bioelectron 2022; 214:114511. [DOI: 10.1016/j.bios.2022.114511] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2022] [Revised: 06/21/2022] [Accepted: 06/23/2022] [Indexed: 11/30/2022]
|
22
|
Wang WJ, Chou MC, Lee YJ, Hsu WL, Wang GJ. A simple electrochemical immunosensor based on a gold nanoparticle monolayer electrode for neutrophil gelatinase-associated lipocalin detection. Talanta 2022; 246:123530. [DOI: 10.1016/j.talanta.2022.123530] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2021] [Revised: 04/23/2022] [Accepted: 05/04/2022] [Indexed: 01/23/2023]
|
23
|
Cho CH, Son SY, Bang JK, Jeon YH, Park JP. Biophysical and electrochemical approaches for studying molecular recognition of IL-33 binding peptides identified via phage display. Anal Chim Acta 2022; 1197:339522. [DOI: 10.1016/j.aca.2022.339522] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Revised: 01/13/2022] [Accepted: 01/17/2022] [Indexed: 01/18/2023]
|
24
|
Abstract
Acute kidney injury (AKI) is one of the most prevalent and complex clinical syndromes with high morbidity and mortality. The traditional diagnosis parameters are insufficient regarding specificity and sensitivity, and therefore, novel biomarkers and their facile and rapid applications are being sought to improve the diagnostic procedures. The biosensors, which are employed on the basis of electrochemistry, plasmonics, molecular probes, and nanoparticles, are the prominent ways of developing point-of-care devices, along with the mutual integration of efficient surface chemistry strategies. In this manner, biosensing platforms hold pivotal significance in detecting and quantifying novel AKI biomarkers to improve diagnostic interventions, potentially accelerating clinical management to control the injury in a timely manner. In this review, novel diagnostic platforms and their manufacturing processes are presented comprehensively. Furthermore, strategies to boost their effectiveness are also indicated with several applications. To maximize these efforts, we also review various biosensing approaches with a number of biorecognition elements (e.g., antibodies, aptamers, and molecular imprinting molecules), as well as benchmark their features such as robustness, stability, and specificity of these platforms.
Collapse
Affiliation(s)
- Esma Derin
- UNAM-National Nanotechnology Research Center, Bilkent University, 06800 Ankara, Turkey
- Institute of Materials Science and Nanotechnology, Bilkent University, 06800 Ankara, Turkey
| | - Fatih Inci
- UNAM-National Nanotechnology Research Center, Bilkent University, 06800 Ankara, Turkey
- Institute of Materials Science and Nanotechnology, Bilkent University, 06800 Ankara, Turkey
| |
Collapse
|
25
|
Lin CY, Nhat Nguyen UT, Hsieh HY, Tahara H, Chang YS, Wang BY, Gu BC, Dai YH, Wu CC, Tsai IJ, Fan YJ. Peptide-based electrochemical sensor with nanogold enhancement for detecting rheumatoid arthritis. Talanta 2022; 236:122886. [PMID: 34635266 DOI: 10.1016/j.talanta.2021.122886] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2021] [Revised: 07/12/2021] [Accepted: 09/12/2021] [Indexed: 01/30/2023]
Abstract
Rheumatoid arthritis (RA), an autoimmune and chronic inflammatory disorder, is an incurable disease. We developed a peptide-based electrochemical sensor using electrochemical impedance spectroscopy that can be used to detect autoantibodies for RA diagnostics. We first validated that the developed peptide showed high sensitivity and could compliment the current gold standard method of an anti-cyclic citrullinated peptide antibody (anti-CCP) ELISA. The developed peptide can be modified on the nanogold surface of the working electrode of sensing chips through the method of a self-assembling monolayer. The sensing process was first optimized using a positive control cohort and a healthy control cohort. Subsequently, 10 clinically confirmed samples from RA patients and five healthy control samples were used to find the threshold value of the impedance between RA and healthy subjects. Furthermore, 10 clinically confirmed samples but with low values of anti-CCP autoantibodies were used to evaluate the sensitivity of the present method compared to the conventional method. The proposed method showed better sensitivity than the current conventional anti-CCP ELISA method.
Collapse
Affiliation(s)
- Ching-Yu Lin
- PhD Program in Medical Biotechnology, College of Medical Science and Technology, Taipei Medical University, 250 Wuxing St., Taipei, 11031, Taiwan
| | - Uyen Thi Nhat Nguyen
- International PhD Program for Cell Therapy and Regeneration Medicine, Taipei Medical University, 250 Wuxing St., Taipei, 11031, Taiwan
| | - Han-Yun Hsieh
- Graduate School of Biomedical & Health Sciences, Hiroshima University, Kausmi 1-2-3, Minami-ku, Hiroshima, 734-8553, Japan; Institute of Applied Mechanics, National Taiwan University, 1 Roosevelt Road, Sec. 4, Taipei, 10617, Taiwan
| | - Hidetoshi Tahara
- Graduate School of Biomedical & Health Sciences, Hiroshima University, Kausmi 1-2-3, Minami-ku, Hiroshima, 734-8553, Japan
| | - Yu-Sheng Chang
- Division of Allergy, Immunology and Rheumatology, Shuang Ho Hospital, 291 Zhongzheng Rd., Zhonghe District, New Taipei City, 23561, Taiwan; Division of Allergy, Immunology and Rheumatology, Department of Internal Medicine, School of Medicine, College of Medicine, Taipei Medical University, 250 Wuxing St., Taipei, 11031, Taiwan
| | - Bing-Yu Wang
- Department of Mechanical Engineering, National Chung-Hsing University, 145 Xingda Rd., South Dist., Taichung, 40227, Taiwan
| | - Bing-Chen Gu
- Vida BioTechnology Co., Ltd. Taiwan, 145 Xingda Rd., South Dist., Taichung, 402, Taiwan
| | - Yu-Han Dai
- Vida BioTechnology Co., Ltd. Taiwan, 145 Xingda Rd., South Dist., Taichung, 402, Taiwan
| | - Chia-Che Wu
- Department of Mechanical Engineering, National Chung-Hsing University, 145 Xingda Rd., South Dist., Taichung, 40227, Taiwan
| | - I-Jung Tsai
- PhD Program in Medical Biotechnology, College of Medical Science and Technology, Taipei Medical University, 250 Wuxing St., Taipei, 11031, Taiwan
| | - Yu-Jui Fan
- International PhD Program for Cell Therapy and Regeneration Medicine, Taipei Medical University, 250 Wuxing St., Taipei, 11031, Taiwan; International PhD Program for Biomedical Engineering, School of Biomedical Engineering, Taipei Medical University, 250 Wuxing St., Taipei, 11031, Taiwan.
| |
Collapse
|
26
|
Sfragano PS, Moro G, Polo F, Palchetti I. The Role of Peptides in the Design of Electrochemical Biosensors for Clinical Diagnostics. BIOSENSORS-BASEL 2021; 11:bios11080246. [PMID: 34436048 PMCID: PMC8391273 DOI: 10.3390/bios11080246] [Citation(s) in RCA: 42] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Revised: 07/10/2021] [Accepted: 07/19/2021] [Indexed: 12/31/2022]
Abstract
Peptides represent a promising class of biorecognition elements that can be coupled to electrochemical transducers. The benefits lie mainly in their stability and selectivity toward a target analyte. Furthermore, they can be synthesized rather easily and modified with specific functional groups, thus making them suitable for the development of novel architectures for biosensing platforms, as well as alternative labelling tools. Peptides have also been proposed as antibiofouling agents. Indeed, biofouling caused by the accumulation of biomolecules on electrode surfaces is one of the major issues and challenges to be addressed in the practical application of electrochemical biosensors. In this review, we summarise trends from the last three years in the design and development of electrochemical biosensors using synthetic peptides. The different roles of peptides in the design of electrochemical biosensors are described. The main procedures of selection and synthesis are discussed. Selected applications in clinical diagnostics are also described.
Collapse
Affiliation(s)
- Patrick Severin Sfragano
- Department of Chemistry “Ugo Schiff”, University of Florence, Via della Lastruccia 3, 50019 Sesto Fiorentino, Italy;
| | - Giulia Moro
- Department of Molecular Sciences and Nanosystems, Ca’ Foscari University of Venice, Via Torino 155, 30172 Venice, Italy; (G.M.); (F.P.)
| | - Federico Polo
- Department of Molecular Sciences and Nanosystems, Ca’ Foscari University of Venice, Via Torino 155, 30172 Venice, Italy; (G.M.); (F.P.)
| | - Ilaria Palchetti
- Department of Chemistry “Ugo Schiff”, University of Florence, Via della Lastruccia 3, 50019 Sesto Fiorentino, Italy;
- Correspondence:
| |
Collapse
|
27
|
Kurup CP, Mohd-Naim NF, Tlili C, Ahmed MU. A Highly Sensitive Label-free Aptasensor Based on Gold Nanourchins and Carbon Nanohorns for the Detection of Lipocalin-2 (LCN-2). ANAL SCI 2021; 37:825-831. [PMID: 33041307 DOI: 10.2116/analsci.20p303] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
A synergistic nanocomposite film composed of gold nanourchins (AuNU), oxidised carbon nanohorns (CNH), and chitosan functioned as an electrode modifier in the fabrication of the sensitive lipocalin-2 (LCN-2) aptasensor. The AuNUs/CNH/CS composite increased the surface area and thereby amplified the signal transduction. The amine-terminated LCN-2 aptamer was immobilised through the amide bond formed between the carboxyl group of polyglutamic acid (PGA) and the amine group of aptamer. Interaction of LCN-2 with the aptamer caused conformational changes in the structure of the aptamer. This generated higher conductivity, resulting in increased DPV peak current. The DPV signal increased with increasing concentration of LCN-2, and the change in signal was used for quantitative detection. The proposed aptasensor was able to detect LCN-2 in the linear range of 0.1 - 100.0 pg mL-1, with a low detection limit of 10 fg mL-1. The aptasensor showed high sensitivity, selectivity, reproducibility, and was able to detect LCN-2 in serum samples.
Collapse
Affiliation(s)
- Chitra Padmakumari Kurup
- Biosensors and Nanobiotechnology Laboratory, Integrated Science Building, Faculty of Science, Universiti Brunei Darussalam
| | | | - Chaker Tlili
- Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences
| | - Minhaz Uddin Ahmed
- Biosensors and Nanobiotechnology Laboratory, Integrated Science Building, Faculty of Science, Universiti Brunei Darussalam
| |
Collapse
|
28
|
Electrochemiluminescence sensor based on cyclic peptides-recognition and Au nanoparticles assisted graphitic carbon nitride for glucose determination. Mikrochim Acta 2021; 188:151. [PMID: 33813618 DOI: 10.1007/s00604-021-04797-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2020] [Accepted: 03/18/2021] [Indexed: 01/16/2023]
Abstract
A glucose (Glu) sensor was designed by introducing synthetic cyclic peptides (CPs) as recognition receptors and Au nanoparticles assisted graphitic carbon nitride (AuNPs/g-C3N4) for electrochemiluminescence (ECL) enhancement. The synthetic CP receptor (cyclo-[-CNDNHCRDNDC-]) with natural active center of Glu binding protein can mimic the interactions between Glu and Glu binding protein to specifically capture Glu. The AuNPs were reduced on g-C3N4 and formed a new nanohybrid that can be applied as an ECL emitter. The AuNPs/g-C3N4 effectively ameliorated the ECL response of bare g-C3N4. The ECL enhancement mechanism was theoretically speculated through computer simulation. Glu quantification was conducted by recording ECL shifts induced by the binding of Glu to CPs. The linear detection range of the fabricated CPs-based ECL sensor was 1 to 100 mmol L-1, and the detection limit (LOD) was 0.57 nmol L-1 (S / N = 3). The CP-based ECL sensor also showed good specificity, repeatability, stability, and favorable recoveries in sample analysis. This work offer a promising analytical method for Glu assay in clinical diagnostics and bioprocess monitoring.
Collapse
|
29
|
Xu P, Ghosh S, Gul AR, Bhamore JR, Park JP, Park TJ. Screening of specific binding peptides using phage-display techniques and their biosensing applications. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116229] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
30
|
Danvirutai P, Ekpanyapong M, Tuantranont A, Bohez E, Anutrakulchai S, Wisitsoraat A, Srichan C. Ultra-sensitive and label-free neutrophil gelatinase-associated lipocalin electrochemical sensor using gold nanoparticles decorated 3D Graphene foam towards acute kidney injury detection. SENSING AND BIO-SENSING RESEARCH 2020. [DOI: 10.1016/j.sbsr.2020.100380] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
|
31
|
Cho CH, Kim JH, Kim J, Yun JW, Park TJ, Park JP. Re-engineering of peptides with high binding affinity to develop an advanced electrochemical sensor for colon cancer diagnosis. Anal Chim Acta 2020; 1146:131-139. [PMID: 33461708 DOI: 10.1016/j.aca.2020.11.011] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2020] [Revised: 10/17/2020] [Accepted: 11/07/2020] [Indexed: 02/07/2023]
Abstract
Colorectal cancer (CRC) develops from polyps in the inner large intestine or rectum and an increasing incidence and high mortality rate has been observed in humans. Currently, colonoscopy is the preferred modality for early CRC diagnosis. However, this technique has several limitations, such as high medical costs and intricate procedures, leading to increasing demands for the development of a new, simple, and affordable diagnostic method. In this study, an advanced electrochemical biosensor based on rationally designed affinity peptides was developed for discriminating adenoma to carcinoma progression. Amino acid-substituted and rationally designed synthetic peptides (BP3-1 to BP3-8) based on in silico modeling studies were chemically synthesized, and covalently immobilized onto a gold electrode using aromatic ring compounds through surface chemistry techniques. The binding performance of the developed sensor system was observed using square wave voltammetry (SWV). The peptide BP3-2 was selected depending on its relative binding affinity; SWV indicated the limit of detection of BP3-2 for LRG1 to be 0.025 μg/mL. This sensor could distinguish the adenoma-carcinoma transition with improved binding abilities (specificity and selectivity), and stability in plasma samples spiked with LRG1 and real samples from patients with CRC. These results indicate that this electrochemical sensor system can be used for early monitoring of the colorectal adenoma to carcinoma progression.
Collapse
Affiliation(s)
- Chae Hwan Cho
- Department of Food Science and Technology, Chung-Ang University, Anseong, 17546, Republic of Korea
| | - Ji Hong Kim
- Department of Food Science and Technology, Chung-Ang University, Anseong, 17546, Republic of Korea
| | - Jayoung Kim
- Departments of Surgery and Biomedical Sciences, Cedars-Sinai Medical Center, Los Angeles, CA, USA; Department of Medicine, University of California Los Angeles, CA, 90095, USA
| | - Jong Won Yun
- Department of Biotechnology, Daegu University, Gyeongsan, 38453, Republic of Korea
| | - Tae Jung Park
- Department of Chemistry, Institute of Interdisciplinary Convergence Research, Research Institute of Chem-Bio Diagnostic Technology, Chung-Ang University, 84 Heukseok-ro, Dongjak-gu, Seoul, 06974, Republic of Korea.
| | - Jong Pil Park
- Department of Food Science and Technology, Chung-Ang University, Anseong, 17546, Republic of Korea.
| |
Collapse
|
32
|
Cross-linkage urease nanoparticles: a high-efficiency signal-generation tag for portable pH meter-based electrochemical immunoassay of lipocalin-2 protein diagnostics. Mikrochim Acta 2020; 187:485. [DOI: 10.1007/s00604-020-04466-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Accepted: 07/25/2020] [Indexed: 12/20/2022]
|
33
|
Abstract
Bacteriophages are interesting entities on the border of biology and chemistry. In nature, they are bacteria parasites, while, after genetic manipulation, they gain new properties, e.g., selectively binding proteins. Owing to this, they may be applied as recognition elements in biosensors. Combining bacteriophages with different transducers can then result in the development of innovative sensor designs that may revolutionize bioanalytics and improve the quality of medical services. Therefore, here, we review the use of bacteriophages, or peptides from bacteriophages, as new sensing elements for the recognition of biomarkers and the construction of the highly effective diagnostics tools.
Collapse
|
34
|
Multiple self-cleaning paper-based electrochemical ratiometric biosensor based on the inner reference probe and exonuclease III-assisted signal amplification strategy. Biosens Bioelectron 2020; 147:111769. [DOI: 10.1016/j.bios.2019.111769] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2019] [Revised: 09/24/2019] [Accepted: 10/07/2019] [Indexed: 02/07/2023]
|
35
|
An antifouling peptide-based biosensor for determination of Streptococcus pneumonia markers in human serum. Biosens Bioelectron 2019; 151:111969. [PMID: 31999579 DOI: 10.1016/j.bios.2019.111969] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2019] [Revised: 12/13/2019] [Accepted: 12/14/2019] [Indexed: 12/26/2022]
Abstract
We report a peptide-based sensor that involves a multivalent interaction with L-ascorbate 6-phosphate lactonase (UlaG), a protein marker of Streptococcus pneumonia. By integrating the antifouling feature of the sensor, we significantly improved the signal-to-noise ratio of UlaG detection. The antifouling surface was fabricated via electrodeposition using an equivalent mixture of 4-amino-N,N,N-trimethylanilinium and 4-aminobenzenesulfonate. This antifouling layer not only effectively reduces the non-specific adsorption on the biosensor but also decreases the charge transfer resistance (Rct) of the screen-printed carbon electrode. The aniline-modified S7 peptide, an UlaG-binding peptide, was pre-synthesized and further electrochemically modified to bind onto the antifouling layer. Bio-electrochemical analysis confirms that the antifouling S7-peptide sensor binds strongly to the UlaG with a dissociation constant (Kd) = 0.5 nM. This strong interaction can be attributed to a multivalent interaction between the biosensor and the heximeric form of UlaG. To demonstrate the potential for clinical application, further detection of Streptococcus pneumonia from 50 to 5×104 CFU/mL were successfully performed in 25% human serum.
Collapse
|
36
|
Zhou L, Wang Y, Xing R, Chen J, Liu J, Li W, Liu Z. Orthogonal dual molecularly imprinted polymer-based plasmonic immunosandwich assay: A double characteristic recognition strategy for specific detection of glycoproteins. Biosens Bioelectron 2019; 145:111729. [PMID: 31581071 DOI: 10.1016/j.bios.2019.111729] [Citation(s) in RCA: 50] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2019] [Revised: 09/20/2019] [Accepted: 09/21/2019] [Indexed: 12/27/2022]
Abstract
Sensitive and specific detection methods are critical to the detection of glycoproteins. Immunoassay has been a powerful tool for this purpose, in which antibodies or their mimics particularly molecularly imprinted polymers (MIPs) are used for specific recognition. Epitope and glycan are two structure features of a glycoprotein. However, immunoassays based on simultaneous recognition towards the two characteristics have been scarcely explored so far. Herein we present a new strategy called orthogonal dual molecularly imprinted polymer-based plasmonic immunosandwich assay (odMIP-PISA). It relies on double recognition towards a target glycoprotein by two different types of MIPs, using epitope-imprinted gold nanoparticles (AuNPs)-coated slide as capturing substrate to recognize the peptide epitope and glycans-imprinted Raman-active silver nanoparticles as labeling nanotags to recognize the glycans. Carcinoembryonic antigen (CEA), a routinely used marker for colon cancer, was used as a test glycoprotein. The orthogonal double recognition apparently improved the specificity, reducing the maximum cross-reactivity from 14.4% for epitope recognition and 15.2% for glycan recognition to 8.2% for double recognition. Meanwhile, the plasmonic nanostructure-based Raman detection provided ultrahigh sensitivity, yielding a limit of detection of 5.56 × 10-14 M (S/N = 10). Through measuring the CEA level in human serum, this method permitted differentiation of colon cancer patient from healthy individual. Compared with the traditional immunoassay, odMIP-PISA exhibited multiple advantages, including simplified procedure (6 steps), speed (30 min), reduced cost, and so on. Therefore, this new approach holds great promise in many applications particularly clinical diagnosis.
Collapse
Affiliation(s)
- Lingli Zhou
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210023, China
| | - Yijia Wang
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210023, China
| | - Rongrong Xing
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210023, China
| | - Jin Chen
- Department of Medical Oncology, Jiangsu Cancer Hospital, Nanjing, 210009, China
| | - Jia Liu
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210023, China
| | - Wei Li
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210023, China
| | - Zhen Liu
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210023, China.
| |
Collapse
|