1
|
Ge X, Zhang M, Yin F, Sun Q, Mo F, Huang X, Zheng Y, Wu G, Zhang Y, Shen Y. Supramolecular assembly-induced electrochemiluminescence enhancement of gold nanoclusters for hemoglobin detection. J Mater Chem B 2024; 12:1355-1360. [PMID: 38230749 DOI: 10.1039/d3tb02892e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2024]
Abstract
Gold nanoclusters (Au NCs) with excellent optical properties and biocompatibility have become one of the most promising electrochemiluminescence (ECL) emitters. However, the low efficiency and poor stability of Au NCs restrict their applications in ECL. Herein, by supramolecular assembly of L-arginine (Arg) and 4-hydroxy-2-mercapto-6-methylpyrimidine (MTU) on the surface of Au NCs, Arg/MTU-Au NCs with enhanced ECL efficiency and stability were prepared. Compared with the MTU-stabilized Au NCs (MTU-Au NCs), the ECL efficiency of Arg/MTU-Au NCs increased by 24.8 times. As a proof-of-concept, a sensitive biosensing platform was constructed for sensitive detection of hemoglobin (Hb) in urine using Arg/MTU-Au NCs as ECL emitters. The proposed ECL detection platform provides a feasible strategy for the detection of biomarkers in urine and has broad application prospects in disease screening and clinical marker detection.
Collapse
Affiliation(s)
- Xue Ge
- Medical School, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 210009, China.
| | - Mingming Zhang
- Center of Clinical Laboratory Medicine, Zhongda Hospital, Southeast University, Nanjing 210009, China
| | - Fei Yin
- Medical School, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 210009, China.
| | - Qian Sun
- Medical School, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 210009, China.
| | - Fan Mo
- Medical School, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 210009, China.
| | - Xinzhou Huang
- Medical School, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 210009, China.
| | - Ying Zheng
- Medical School, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 210009, China.
| | - Guoqiu Wu
- Center of Clinical Laboratory Medicine, Zhongda Hospital, Southeast University, Nanjing 210009, China
- Jiangsu Provincial Key Laboratory of Critical Care Medicine, Southeast University, Nanjing 210009, China
| | - Yuanjian Zhang
- Medical School, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 210009, China.
| | - Yanfei Shen
- Medical School, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 210009, China.
- Center of Clinical Laboratory Medicine, Zhongda Hospital, Southeast University, Nanjing 210009, China
- Jiangsu Provincial Key Laboratory of Critical Care Medicine, Southeast University, Nanjing 210009, China
| |
Collapse
|
2
|
Lu TC, Yang YJ, Zhong Y, Qiu QZ, Chen ZH, Chen YZ, Lei Y, Liu AL. Simultaneous detection of C-reactive protein and lipopolysaccharide based on a dual-channel electrochemical biosensor for rapid Gram-typing of bacterial sepsis. Biosens Bioelectron 2024; 243:115772. [PMID: 37879271 DOI: 10.1016/j.bios.2023.115772] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2023] [Revised: 09/15/2023] [Accepted: 10/16/2023] [Indexed: 10/27/2023]
Abstract
Sepsis is a life-threatening multi-organ failure syndrome, with bacterial infections being the most common cause. Rapid Gram-typing is imperative to assist in antibiotic intervention. C-reactive protein (CRP) and lipopolysaccharide (LPS) are effective biomarkers for discerning the Gram type of bacteria but differ by several orders of magnitude in clinical detection, thereby impeding their simultaneous detection. And two independent methods are time-consuming and laborious. In this study, a dual-channel electrochemical biosensor was developed for simultaneous detection of LPS and CRP. Under optimal conditions, linear ranges of LPS (0.5-1000 pg/mL) and CRP (0.1-20 μg/mL) were obtained in line with the clinical evaluation scopes. In simulated sample tests, Gram-positive, Gram-negative, and healthy plasma samples were clearly distinguished by the developed biosensors, and these results were consistent with that of enzyme-linked immunosorbent assay (ELISA). In addition, the results of the plasma samples tested by the electrochemical biosensor matched those derived from blood cultures in the laboratory. Collectively, the electrochemical biosensor was expected to provide the scientific basis for the rapid Gram-typing and point-of-care detection of bacterial sepsis.
Collapse
Affiliation(s)
- Tai-Cheng Lu
- Department of Pharmaceutical Analysis, Higher Educational Key Laboratory for Nano Biomedical Technology of Fujian Province, Faculty of Pharmacy, Fujian Medical University, Fuzhou, 350122, China
| | - Yuan-Jie Yang
- Department of Pharmaceutical Analysis, Higher Educational Key Laboratory for Nano Biomedical Technology of Fujian Province, Faculty of Pharmacy, Fujian Medical University, Fuzhou, 350122, China
| | - Yu Zhong
- Department of Pharmaceutical Analysis, Higher Educational Key Laboratory for Nano Biomedical Technology of Fujian Province, Faculty of Pharmacy, Fujian Medical University, Fuzhou, 350122, China
| | - Qing-Zhen Qiu
- Department of Pharmaceutical Analysis, Higher Educational Key Laboratory for Nano Biomedical Technology of Fujian Province, Faculty of Pharmacy, Fujian Medical University, Fuzhou, 350122, China
| | - Zhen-Hua Chen
- Department of Pharmaceutical Analysis, Higher Educational Key Laboratory for Nano Biomedical Technology of Fujian Province, Faculty of Pharmacy, Fujian Medical University, Fuzhou, 350122, China
| | - Yuan-Zhong Chen
- Fujian Institute of Hematology, The Affiliated Union Hospital of Fujian Medical University, Fuzhou, 350000, China.
| | - Yun Lei
- Department of Pharmaceutical Analysis, Higher Educational Key Laboratory for Nano Biomedical Technology of Fujian Province, Faculty of Pharmacy, Fujian Medical University, Fuzhou, 350122, China.
| | - Ai-Lin Liu
- Department of Pharmaceutical Analysis, Higher Educational Key Laboratory for Nano Biomedical Technology of Fujian Province, Faculty of Pharmacy, Fujian Medical University, Fuzhou, 350122, China.
| |
Collapse
|
3
|
Cao Y, Chen Y, He Y, Lu K, Zheng Q, Jia N. Triple-Mode Sensor Coupled by Photoelectrochemical, Electrochromic, and Spectral Signals for Sensitive Visualized Detection of Nonylphenol. ACS Sens 2023; 8:4676-4685. [PMID: 37973383 DOI: 10.1021/acssensors.3c01733] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2023]
Abstract
Conventional photoelectrochemical (PEC) biosensors suffer from the difficulty of visualizing rapid detection and limited accuracy due to a single-signal output. Here, we develop a PEC, electrochromic (EC), and spectral (ST) triple-mode platform for the sensitive visualized detection of nonylphenol (NP). First, the reasonably stepped Fermi energy level arrangement between the defective TiO2 anode and MoO3 cathode enables a remarkable photocurrent response (Mode 1). Then, MoO3 itself is a widely used EC candidate, which can react with free Li-ions to form a LixMoO3 intermediate, and its color will change from white to blue accordingly (Mode 2). More importantly, MoO3 is also a Li-ion host and the potential of LixMoO3 depends on the inserted Li-ion quantity deduced by spectral analysis on residual Li-ions in the electrolyte (Mode 3). The EC signal endows fast visual detection, and triple-mode cross-validation improves reliability and accuracy. As a result, this PEC-EC-ST triple-mode molecularly imprinted sensor has a wide linear range (1-5000 μg L-1), a low detection limit (0.18 μg L-1), selectivity, stability, reproducibility, and actual sample detection capability. This innovative multimode platform not only improves detection reliability but also broadens applications of electrochromic/energy storage materials in biosensors.
Collapse
Affiliation(s)
- Yuyan Cao
- The Education Ministry Key Lab of Resource Chemistry, Joint International Research Laboratory of Resource Chemistry, Ministry of Education, Shanghai Frontiers Science Center of Biomimetic Catalysis, Shanghai Key Laboratory of Rare Earth Functional Materials, College of Chemistry and Materials Science, Shanghai Normal University, Shanghai 200234, China
| | - Yang Chen
- The Education Ministry Key Lab of Resource Chemistry, Joint International Research Laboratory of Resource Chemistry, Ministry of Education, Shanghai Frontiers Science Center of Biomimetic Catalysis, Shanghai Key Laboratory of Rare Earth Functional Materials, College of Chemistry and Materials Science, Shanghai Normal University, Shanghai 200234, China
| | - Yuhui He
- The Education Ministry Key Lab of Resource Chemistry, Joint International Research Laboratory of Resource Chemistry, Ministry of Education, Shanghai Frontiers Science Center of Biomimetic Catalysis, Shanghai Key Laboratory of Rare Earth Functional Materials, College of Chemistry and Materials Science, Shanghai Normal University, Shanghai 200234, China
| | - Kening Lu
- The Education Ministry Key Lab of Resource Chemistry, Joint International Research Laboratory of Resource Chemistry, Ministry of Education, Shanghai Frontiers Science Center of Biomimetic Catalysis, Shanghai Key Laboratory of Rare Earth Functional Materials, College of Chemistry and Materials Science, Shanghai Normal University, Shanghai 200234, China
| | - Qi Zheng
- The Education Ministry Key Lab of Resource Chemistry, Joint International Research Laboratory of Resource Chemistry, Ministry of Education, Shanghai Frontiers Science Center of Biomimetic Catalysis, Shanghai Key Laboratory of Rare Earth Functional Materials, College of Chemistry and Materials Science, Shanghai Normal University, Shanghai 200234, China
| | - Nengqin Jia
- The Education Ministry Key Lab of Resource Chemistry, Joint International Research Laboratory of Resource Chemistry, Ministry of Education, Shanghai Frontiers Science Center of Biomimetic Catalysis, Shanghai Key Laboratory of Rare Earth Functional Materials, College of Chemistry and Materials Science, Shanghai Normal University, Shanghai 200234, China
| |
Collapse
|
4
|
Wang G, Han D, Zhang Q. Highly sensitive detection of circulating tumour cells based on an ASV/CV dual-signal electrochemical strategy. RSC Adv 2023; 13:33038-33046. [PMID: 38025856 PMCID: PMC10631473 DOI: 10.1039/d3ra04856j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Accepted: 10/19/2023] [Indexed: 12/01/2023] Open
Abstract
Circulating tumour cells (CTCs), as a tumour marker, may provide more information in early diagnosis and accurate therapy of cancer patients. Electrochemical detection of CTCs has exhibited exceptional advantages. However, single-signal electrochemical detection usually has a high probability of false positives coming from interferents, operating personnel, and nonstandard analytical processes. Herein, a dual-signal strategy using anodic stripping voltammetry (ASV) and cyclic voltammetry (CV) for highly sensitive detection of CTCs was developed. When MCF-7 cells were present, aptamer DNA (DNA1)-magnetic beads (MBs) were captured by CTCs and detached from the biosensing electrodes. Following magnetic separation, polystyrene bead (PS)-CdS QDs labelled on MCF-7 cells were dissolved by HNO3 and the intensity of the oxidation peak current of Cd2+ ions was proportional to the amount of MCF-7 cells in ASV (y = 6.8929 lg Ccells + 1.0357 (Ccells, cells per mL; R2, 0.9947; LOD, 3 cells per mL)). Meanwhile, the anodic peak currents of the remaining electrode in CV were also proportional to the amount of MCF-7 cells (y = 3.7891 lg Ccells + 52.3658 (Ccells, cells per mL; R2, 0.9846; LOD, 3 cells per mL)). An ASV/CV dual-signal biosensor for electrochemical detection of CTCs was achieved, which overcame the limitations of any single-signal mode and improved the detection reliability and precision.
Collapse
Affiliation(s)
- Gang Wang
- Department of Gastroenterology, Tianjin Medical University General Hospital Anshan Road 154, Heping District Tianjin 300052 China
| | - Dan Han
- Department of Gastroenterology, Tianjin Medical University General Hospital Anshan Road 154, Heping District Tianjin 300052 China
| | - Qingyu Zhang
- Department of Gastroenterology, Tianjin Medical University General Hospital Anshan Road 154, Heping District Tianjin 300052 China
| |
Collapse
|
5
|
Liu M, Dong J, Suo Z, Wang Q, Wei M, He B, Jin H. A convenient fluorescent/electrochemical dual-mode biosensor for accurate detection of Pb 2+ based on DNAzyme cycle. Bioelectrochemistry 2023; 152:108452. [PMID: 37137224 DOI: 10.1016/j.bioelechem.2023.108452] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2023] [Revised: 03/28/2023] [Accepted: 04/22/2023] [Indexed: 05/05/2023]
Abstract
The presence of heavy metals in the ecological environment is a serious threat to human health. Therefore, it is very important to establish a simple and sensitive method for the detection of heavy metals. Currently, most of the methods are single-channel sensing, and these methods are prone to false-positive signals, which reduces the accuracy. In this work, Pb2+-DNAzyme was immobilized on magnetic beads (MBs) using a linkage of biotin and streptavidin and successfully applied to the construction of a fluorescent/electrochemical dual-mode (DM) biosensor. The supernatant after magnetic separation formed a double strand on the electrode, which was combined with methylene blue (MB) for electrochemical detection (EC). At the same time, FAM-d was added to the precipitate, and after magnetic separation, the supernatant was subjected to fluorescent detection (FL). Under optimal conditions, the signal response of the constructed dual-mode biosensor showed a good linear relationship with the concentration of Pb2+. The DNAzyme-based dual-mode biosensor achieved sensitive and selective detection of Pb2+ with good accuracy and reliability, opening a new way for the development of biosensing strategies for the detection of Pb2+. More importantly, the sensor has high sensitivity and accuracy for the detection of Pb2+ in actual sample analysis.
Collapse
Affiliation(s)
- Mingwei Liu
- College of Food Science and Technology, Henan Key Laboratory of Cereal and Oil Food Safety Inspection and Control, Henan University of Technology, Zhengzhou 450001, China
| | - Jie Dong
- College of Food Science and Technology, Henan Key Laboratory of Cereal and Oil Food Safety Inspection and Control, Henan University of Technology, Zhengzhou 450001, China
| | - Zhiguang Suo
- College of Food Science and Technology, Henan Key Laboratory of Cereal and Oil Food Safety Inspection and Control, Henan University of Technology, Zhengzhou 450001, China.
| | - Qixuan Wang
- College of Food Science and Technology, Henan Key Laboratory of Cereal and Oil Food Safety Inspection and Control, Henan University of Technology, Zhengzhou 450001, China
| | - Min Wei
- College of Food Science and Technology, Henan Key Laboratory of Cereal and Oil Food Safety Inspection and Control, Henan University of Technology, Zhengzhou 450001, China
| | - Baoshan He
- College of Food Science and Technology, Henan Key Laboratory of Cereal and Oil Food Safety Inspection and Control, Henan University of Technology, Zhengzhou 450001, China
| | - Huali Jin
- College of Food Science and Technology, Henan Key Laboratory of Cereal and Oil Food Safety Inspection and Control, Henan University of Technology, Zhengzhou 450001, China.
| |
Collapse
|
6
|
Du S, Xie B, Gao H, Zhang J, Fu H, Liao F, Liao Y. Self-Powered DNAzyme Walker Enables Dual-Mode Biosensor Construction for Electrochemiluminescence and Electrochemical Detection of MicroRNA. Anal Chem 2023; 95:7006-7013. [PMID: 37083199 DOI: 10.1021/acs.analchem.3c00546] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/22/2023]
Abstract
Herein, an electrochemiluminescence (ECL) and electrochemical (EC) dual-mode biosensor platform with a self-powered DNAzyme walking machine was established for accurate and sensitive detection of miRNA-21. By employing a magnesium ion (Mn2+)-dependent DNAzyme cleavage cycling reaction, the walking machine was built by assembling DNAzyme walking strands and ferrocene (Fc)-labeled substrate strands on the Au nanoparticles and graphitic carbon nitride nanosheet (g-C3N4 NS)-covered electrode. The DNAzyme walking strand was first prohibited by a blocker strand. After the addition of target miRNA-21 and Mn2+, the DNAzyme walker could be activated and produce autonomous movements along the electrode track fueled by Mn2+-dependent DNAzyme-catalyzed substrate cleavage without additional energy supply. Notably, each walking step resulted in the cleavage of a substrate strand and the release of a Fc-labeled DNA strand fragment, allowing us to acquire an extreme ECL signal recovery of g-C3N4 inhibited by Fc. Meanwhile, numerous Fc-labeled DNA fragments escaped from the surface of the electrode, directly producing an obvious decrease in the square wave voltammetry (SWV) signal from Fc on the same sensing platform. This work not only avoided difficultly assembling various signal indicators but also significantly improved the sensitivity through using self-powered DNAzyme-walker amplification. Moreover, the proposed design employed the same reaction to produce two signal output modes, which could eliminate the interference from diverse reactive pathways on the outcome to mutually improve the accuracy. Therefore, the dual-mode miRNA-21 biosensor exhibited wide detection ranges of 100 aM to 100 nM with low detection limits of 54.3 and 78.6 aM by ECL and SWV modes, respectively, which provided an efficient and universal biosensing approach with extensive applications in early disease diagnosis and bioanalysis.
Collapse
Affiliation(s)
- Shimao Du
- College of Chemistry and Chemical Engineering, Chemical Synthesis and Pollution Control Key Laboratory of Sichuan Province, China West Normal University, Nanchong, Sichuan 637000, China
| | - Benting Xie
- College of Chemistry and Chemical Engineering, Chemical Synthesis and Pollution Control Key Laboratory of Sichuan Province, China West Normal University, Nanchong, Sichuan 637000, China
| | - Hejun Gao
- College of Chemistry and Chemical Engineering, Chemical Synthesis and Pollution Control Key Laboratory of Sichuan Province, China West Normal University, Nanchong, Sichuan 637000, China
| | - Juan Zhang
- College of Chemistry and Chemical Engineering, Chemical Synthesis and Pollution Control Key Laboratory of Sichuan Province, China West Normal University, Nanchong, Sichuan 637000, China
| | - Hongquan Fu
- College of Chemistry and Chemical Engineering, Chemical Synthesis and Pollution Control Key Laboratory of Sichuan Province, China West Normal University, Nanchong, Sichuan 637000, China
| | - Fang Liao
- College of Chemistry and Chemical Engineering, Chemical Synthesis and Pollution Control Key Laboratory of Sichuan Province, China West Normal University, Nanchong, Sichuan 637000, China
| | - Yunwen Liao
- College of Chemistry and Chemical Engineering, Chemical Synthesis and Pollution Control Key Laboratory of Sichuan Province, China West Normal University, Nanchong, Sichuan 637000, China
| |
Collapse
|
7
|
Jiang J, Huang B, Li N, An C, Sun C, Shen Y, Gooneratne R, Cui H, Zhan S, Wang Y. Simple and fast colorimetric detection of lipopolysaccharide based on aptamer and SYBR Green I mediated aggregation of gold nanoparticles. Int J Biol Macromol 2022; 223:231-239. [PMID: 36347371 DOI: 10.1016/j.ijbiomac.2022.10.276] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Revised: 10/26/2022] [Accepted: 10/31/2022] [Indexed: 11/08/2022]
Abstract
Lipopolysaccharide (LPS) poses a considerable threat to food safety and human health. A colorimetric assay for LPS detection based on LPS binding aptamer (LBA) and SYBR Green I (SG) mediated aggregation of gold nanoparticles (AuNPs) was established. In the absence of LPS, the LBA was absorbed onto the AuNPs surface which prevented SG-induced aggregation of AuNPs, and the sensing system exhibited red color. When LPS was added, it interacted with the LBA, forming a complex. At higher LPS concentration, many LBAs were exhausted resulting in SG-induced aggregation of AuNPs, and color change from red to blue. The range of colorimetric detection of LPS was linear in 0-12 EU/mL, with a limit of detection of 0.1698 EU/mL. Spiked LPS in real samples and interfering substances were also identified. This assay ingeniously using the fluorescent dye SG as an effective trigger of AuNPs aggregation, is rapid and facile than most of those earlier reported LBA-based LPS assays, and there is potential to be modified to construct assays for other targets.
Collapse
Affiliation(s)
- Jiajun Jiang
- Institute of Environment and Sustainable Development in Agriculture, Chinese Academy of Agricultural Sciences, Beijing 100081, China
| | - Bingna Huang
- Institute of Environment and Sustainable Development in Agriculture, Chinese Academy of Agricultural Sciences, Beijing 100081, China
| | - Ningjun Li
- Institute of Environment and Sustainable Development in Agriculture, Chinese Academy of Agricultural Sciences, Beijing 100081, China
| | - Changcheng An
- Institute of Environment and Sustainable Development in Agriculture, Chinese Academy of Agricultural Sciences, Beijing 100081, China
| | - Changjiao Sun
- Institute of Environment and Sustainable Development in Agriculture, Chinese Academy of Agricultural Sciences, Beijing 100081, China
| | - Yue Shen
- Institute of Environment and Sustainable Development in Agriculture, Chinese Academy of Agricultural Sciences, Beijing 100081, China
| | - Ravi Gooneratne
- Department of Wine, Food and Molecular Biosciences, Faculty of Agriculture and Life Sciences, Lincoln University, Lincoln 7647, New Zealand
| | - Haixin Cui
- Institute of Environment and Sustainable Development in Agriculture, Chinese Academy of Agricultural Sciences, Beijing 100081, China
| | - Shenshan Zhan
- Institute of Environment and Sustainable Development in Agriculture, Chinese Academy of Agricultural Sciences, Beijing 100081, China.
| | - Yan Wang
- Institute of Environment and Sustainable Development in Agriculture, Chinese Academy of Agricultural Sciences, Beijing 100081, China.
| |
Collapse
|
8
|
Hu Q, Feng W, Liang Y, Liang Z, Cao X, Li S, Luo Y, Wan J, Ma Y, Han D, Niu L. Boronate Affinity-Amplified Electrochemical Aptasensing of Lipopolysaccharide. Anal Chem 2022; 94:17733-17738. [PMID: 36475636 DOI: 10.1021/acs.analchem.2c05004] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
As lipopolysaccharide (LPS) is closely associated with sepsis and other life-threatening conditions, the point-of-care (POC) detection of LPS is of significant importance to human health. In this work, we illustrate an electrochemical aptasensor for the POC detection of low-abundance LPS by utilizing boronate affinity (BA) as a simple, efficient, and cost-effective amplification strategy. Briefly, the BA-amplified electrochemical aptasensing of LPS involves the tethering of the aptamer receptors and the BA-mediated direct decoration of LPS with redox signal tags. As the polysaccharide chain of LPS contains hundreds of cis-diol sites, the covalent crosslinking between the phenylboronic acid group and cis-diol sites can be harnessed for the site-specific decoration of each LPS with hundreds of redox signal tags, thereby enabling amplified detection. As it involves only a single-step operation (∼15 min), the BA-mediated signal amplification holds the significant advantages of unrivaled simplicity, rapidness, and cost-effectiveness over the conventional nanomaterial- and enzyme-based strategies. The BA-amplified electrochemical aptasensor has been successfully applied to specifically detect LPS within 45 min, with a detection limit of 0.34 pg/mL. Moreover, the clinical utility has been validated based on LPS detection in complex serum samples. As a proof of concept, a portable device has been developed to showcase the potential applicability of the BA-amplified electrochemical LPS aptasensor in the POC testing. In view of its simplicity, rapidness, and cost-effectiveness, the BA-amplified electrochemical LPS aptasensor holds broad application prospects in the POC testing.
Collapse
Affiliation(s)
- Qiong Hu
- Guangzhou Key Laboratory of Sensing Materials and Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| | - Wenxing Feng
- Guangzhou Key Laboratory of Sensing Materials and Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| | - Yiyi Liang
- Guangzhou Key Laboratory of Sensing Materials and Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| | - Zhiwen Liang
- Guangzhou Key Laboratory of Sensing Materials and Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| | - Xiaojing Cao
- Guangzhou Key Laboratory of Sensing Materials and Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| | - Shiqi Li
- Guangzhou Key Laboratory of Sensing Materials and Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| | - Yilin Luo
- Guangzhou Key Laboratory of Sensing Materials and Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| | - Jianwen Wan
- Guangzhou Key Laboratory of Sensing Materials and Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| | - Yingming Ma
- Guangzhou Key Laboratory of Sensing Materials and Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| | - Dongxue Han
- Guangzhou Key Laboratory of Sensing Materials and Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| | - Li Niu
- Guangzhou Key Laboratory of Sensing Materials and Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| |
Collapse
|
9
|
Xie S, Yang H, Teng L, Liang S, Zhang J, Tang Y, Xu Y. A dual-mode of electrochemical-colorimetric biosensing platform for kanamycin detection based on self-sacrifice beacon and magnetic separation technique. Anal Chim Acta 2022; 1236:340590. [DOI: 10.1016/j.aca.2022.340590] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2022] [Revised: 10/28/2022] [Accepted: 11/02/2022] [Indexed: 11/06/2022]
|
10
|
Huang Y, Zhang S, Chen Y, Dai H, Lin Y. Modular and Noncontact Wireless Detection Platform for Ovarian Cancer Markers: Electrochemiluminescent and Photoacoustic Dual-Signal Output Based on Multiresponse Carbon Nano-Onions. Anal Chem 2022; 94:13269-13277. [DOI: 10.1021/acs.analchem.2c03337] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Yitian Huang
- College of Chemistry and Material, Fujian Normal University, Fuzhou, Fujian 350108, China
| | - Shupei Zhang
- College of Chemical and Material Engineering, Quzhou University, Quzhou, Zhejiang 32400, China
| | - Yanjie Chen
- College of Chemistry and Material, Fujian Normal University, Fuzhou, Fujian 350108, China
| | - Hong Dai
- College of Chemistry and Material, Fujian Normal University, Fuzhou, Fujian 350108, China
- College of Chemical and Material Engineering, Quzhou University, Quzhou, Zhejiang 32400, China
| | - Yanyu Lin
- College of Chemistry and Material, Fujian Normal University, Fuzhou, Fujian 350108, China
| |
Collapse
|
11
|
Xue Y, Xie H, Wang Y, Feng S, Sun J, Huang J, Yang X. Novel and sensitive electrochemical/fluorescent dual-mode biosensing platform based on the cascaded cyclic amplification of enzyme-free DDSA and functional nucleic acids. Biosens Bioelectron 2022; 218:114762. [DOI: 10.1016/j.bios.2022.114762] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2022] [Revised: 09/22/2022] [Accepted: 09/24/2022] [Indexed: 11/02/2022]
|
12
|
Highly sensitive and efficient fluorescent sensing for Hg2+ detection based on triple-helix molecular switch and exonuclease III-assisted amplification. Anal Chim Acta 2022; 1205:339751. [DOI: 10.1016/j.aca.2022.339751] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2022] [Revised: 03/04/2022] [Accepted: 03/20/2022] [Indexed: 12/13/2022]
|
13
|
Fan X, Wang S, Liu H, Li Z, Sun Q, Wang Y, Fan X. A sensitive electrochemiluminescence biosensor for assay of cancer biomarker (MMP-2) based on NGQDs-Ru@SiO2 luminophore. Talanta 2022; 236:122830. [PMID: 34635220 DOI: 10.1016/j.talanta.2021.122830] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2021] [Revised: 08/25/2021] [Accepted: 08/27/2021] [Indexed: 12/21/2022]
Abstract
A sensitive biosensor that can be used for the determination of matrix metalloproteinase 2 (MMP-2) was proposed. The biosensor was developed by using an excellent self-enhanced nanocomposites as an illuminant and a peptide as a recognition element. For the electrostatic attraction between Ru(bpy)32+ and nitrogen-doped graphene quantum dots (NGQDs), the self-enhanced electrochemiluminescence (ECL) nanocomposites of NGQDs-Ru(bpy)32+-doped silica nanoparticles (NGQDs-Ru@SiO2) were synthesized through a simple sol-gel process. Then, a specific peptide (labeled sulfhydryl) was combined with the self-enhanced ECL nanocomposites (carboxyl in NGQDs) via acylation reaction to obtain the peptide-NGQDs-Ru@SiO2 nanoprobe, which was fabricated onto the gold electrode surface via Au-S bond. The peptide of the ECL nanoprobe was exposed to cleavage in the presence of MMP-2, which caused the signal substance to move farther away from the electrode, leading to a decrease of the ECL signal. The proposed NGQDs-Ru@SiO2-labeled peptide ECL biosensor displayed a lower detection limit of 6.5 pg mL-1 than those of reported ECL methods. The proposed biosensor provided an outlook for future applications in other disease-associated biomarkers.
Collapse
Affiliation(s)
- Xuemei Fan
- School of Materials Science and Chemical Engineering, Xi'an Technological University, Xi'an, 710021, China; College of Chemical Engineering and Modern Materials, Shangluo University, Shangluo, 726000, China.
| | - Shumin Wang
- College of Chemical Engineering and Modern Materials, Shangluo University, Shangluo, 726000, China
| | - Hugang Liu
- College of Chemical Engineering and Modern Materials, Shangluo University, Shangluo, 726000, China
| | - Zhejian Li
- College of Chemical Engineering and Modern Materials, Shangluo University, Shangluo, 726000, China
| | - Qiangqiang Sun
- College of Chemical Engineering and Modern Materials, Shangluo University, Shangluo, 726000, China
| | - Yimeng Wang
- College of Chemical Engineering and Modern Materials, Shangluo University, Shangluo, 726000, China
| | - Xinhui Fan
- School of Materials Science and Chemical Engineering, Xi'an Technological University, Xi'an, 710021, China; College of Chemical Engineering and Modern Materials, Shangluo University, Shangluo, 726000, China
| |
Collapse
|
14
|
Ge H, Wang X, Xu J, Lin H, Zhou H, Hao T, Wu Y, Guo Z. A CRISPR/Cas12a-Mediated Dual-Mode Electrochemical Biosensor for Polymerase Chain Reaction-Free Detection of Genetically Modified Soybean. Anal Chem 2021; 93:14885-14891. [PMID: 34698496 DOI: 10.1021/acs.analchem.1c04022] [Citation(s) in RCA: 32] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
A clustered regularly interspaced short palindromic repeats (CRISPR)/Cas12a-mediated dual-mode electrochemical biosensor without polymerase chain reaction (PCR) amplification was designed for sensitive and reliable detection of genetically modified soybean SHZD32-1. A functionalized composite bionanomaterial Fe3O4@AuNPs/DNA-Fc&Ru was synthesized as the signal unit, while a characteristic gene fragment of SHZD32-1 was chosen as the target DNA (tDNA). When Cas12a, crRNA, and tDNA were present simultaneously, a ternary complex Cas12a-crRNA-tDNA was formed, and the nonspecific cleavage ability of the CRISPR/Cas12a system toward single-stranded DNA was activated. Thus, the single-stranded DNA-Fc in the signal unit was cleaved, resulting in the decrease in the fast scan voltammetric (FSV) signal from ferrocene (Fc) and the increase in the electrochemiluminescence (ECL) signal from ruthenium complex (Ru) inhibited by Fc. The linear range was 1-107 fmol/L for ECL and 10-108 fmol/L for FSV, and the limit of detection (LOD) was 0.3 fmol/L for ECL and 3 fmol/L for FSV. Accuracy, precision, stability, selectivity, and reliability were all satisfied. In addition, PCR-free detection could be completed in an hour at room temperature without requiring complicated operation and sample processing, showing great potential in the field detection of genetically modified crops.
Collapse
Affiliation(s)
- Haoran Ge
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, School of Material Science and Chemical Engineering, Ningbo University, Ningbo 315211, P.R. China
| | - Xiaofu Wang
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, Zhejiang Academy of Agricultural Sciences, Hangzhou 310021, P.R. China
| | - Junfeng Xu
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, Zhejiang Academy of Agricultural Sciences, Hangzhou 310021, P.R. China
| | - Han Lin
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, School of Material Science and Chemical Engineering, Ningbo University, Ningbo 315211, P.R. China
| | - Huiqian Zhou
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, School of Material Science and Chemical Engineering, Ningbo University, Ningbo 315211, P.R. China
| | - Tingting Hao
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, School of Material Science and Chemical Engineering, Ningbo University, Ningbo 315211, P.R. China
| | - Yangbo Wu
- Faculty of Electrical Engineering and Computer Science, Ningbo University, Ningbo 315211, P.R. China
| | - Zhiyong Guo
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, School of Material Science and Chemical Engineering, Ningbo University, Ningbo 315211, P.R. China
| |
Collapse
|
15
|
An "off-on" electrochemiluminescence biosensor coupled with strand displacement-powered 3D micromolecule walking nanomachine for ultrasensitive detection of adenosine triphosphate. Mikrochim Acta 2021; 188:237. [PMID: 34184148 DOI: 10.1007/s00604-021-04895-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Accepted: 06/12/2021] [Indexed: 10/21/2022]
Abstract
A three-dimensional (3D) micromolecule walking nanomachine propelled by strand displacement was developed to establish a novel switching electrochemiluminescence (ECL) biosensor for ultrasensitive detection of adenosine triphosphate (ATP). Generally, walking nanomachines reported previously were limited to DNA walkers, while the proposed 3D walking nanomachine focused on the micromolecule walker. Firstly, TiO2 and silver nanoparticles (Ag NPs) functionalized N-(4-aminobutyl)-N-(ethylisoluminol) (Ag-ABEI) were deposited onto the electrode surface to offer an enhanced ECL signal, resulting from the double catalytic effect of TiO2 and Ag NPs for H2O2. Following, dopamine (DA)-labeled DNA duplex probes (S1/S2-DA) immobilized onto the modified electrode cut down the original ECL signal due to the quenching of DA toward ABEI (signal-off). Target ATP walker moved along the 3D DNA track, simultaneously releasing numerous DNA3, which was applied to displace S2-DA, resulting in the quenched ECL intensity recovery (signal-on). As a result, the biosensor showed a low limit of detection down to 0.5 nM (S/N = 3) and was successfully employed to determine ATP in human serum samples. Thus, the established biosensing strategy holds great potential for biochemical studies and clinical diagnosis.
Collapse
|
16
|
Zhang J, Gao Y, Zhang X, Feng Q, Zhan C, Song J, Zhang W, Song W. "Dual Signal-On" Split-Type Aptasensor for TNF-α: Integrating MQDs/ZIF-8@ZnO NR Arrays with MB-Liposome-Mediated Signal Amplification. Anal Chem 2021; 93:7242-7249. [PMID: 33960777 DOI: 10.1021/acs.analchem.1c00415] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Ultrasensitive and accurate detection of biomarkers in serum is of great importance for disease diagnosis and treatment. So far, the commonly used single-mode signal suffers from certain instinct drawbacks that restrict assay performances. Herein, we report the proof-of-concept fabrication of a split-type photoelectrochemical (PEC) and electrochemical (EC) dual-modal aptasensor for ultrasensitively tracing tumor necrosis factor-α, a noteworthy biological biomarker with essential clinical importance. By smart integrating molybdenum disulfide QDs/zeolitic imidazolate framework-8@ZnO nanorod arrays with a methylene blue-liposome-mediated signal amplification strategy, "dual signal-on" detection is accomplished based on a sandwich reaction of the target with aptamer-anchored carboxyl magnetic beads and an aptamer-confined MB liposome. Linear ranges of 5 fg/mL-5 μg/mL (detection limit 1.46 fg/mL) for PEC and 10 fg/mL-0.5 μg/mL (detection limit 6.14 fg/mL) for EC are obtained, respectively. An independent signal transduction mechanism supports the accuracy improvement, and a separate biological process from a translator enables convenient fabrication, short-time consumption, wider linearity, as well as outstanding reproducibility and stability in practical application. This work presents a universal bioassay route with prospects in biomedical and related areas.
Collapse
Affiliation(s)
- Jinling Zhang
- College of Chemistry, Jilin University, Changchun 130012, China
| | - Yao Gao
- College of Chemistry, Jilin University, Changchun 130012, China
| | - Xuechen Zhang
- College of Chemistry, Jilin University, Changchun 130012, China
| | - Qianshan Feng
- College of Chemistry, Jilin University, Changchun 130012, China
| | - Chunxu Zhan
- College of Chemistry, Jilin University, Changchun 130012, China
| | - Jialin Song
- College of Chemistry, Jilin University, Changchun 130012, China
| | - Wenhui Zhang
- College of Chemistry, Jilin University, Changchun 130012, China
| | - Wenbo Song
- College of Chemistry, Jilin University, Changchun 130012, China
| |
Collapse
|
17
|
Zhang Q, Fu Y, Xiao K, Du C, Zhang X, Chen J. Sensitive Dual-Mode Biosensors for CYFRA21-1 Assay Based on the Dual-Signaling Electrochemical Ratiometric Strategy and "On-Off-On" PEC Method. Anal Chem 2021; 93:6801-6807. [PMID: 33878864 DOI: 10.1021/acs.analchem.1c00746] [Citation(s) in RCA: 56] [Impact Index Per Article: 18.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Herein, an electrochemical (EC)-photoelectrochemical (PEC) dual-mode biosensor was constructed for cytokeratin 19 fragment 21-1 (CYFRA21-1) assay based on the dual-signaling electrochemical ratiometric strategy and "on-off-on" PEC method. The indium tin oxide (ITO) electrode was modified by 3,4,9,10-perylenetetracarboxylic dianhydride (PTCDA)@C60 and gold nanoparticles (Au NPs), and the double-stranded DNA composed of thiol/methylene blue (MB)-labeled single-stranded DNA (ssDNA) (S0-MB) and antibody/ferrocene (Fc)-labeled ssDNA (Ab1-S1-Fc) was immobilized on the Au NPs/PTCDA@C60/ITO electrode via the Au-S bond between Au NPs and thiol of S0-MB. With the help of another antibody-labeled ssDNA (Ab2-S2), the presence of CYFRA21-1 triggered a typical antigen-antibody sandwich immune reaction (Ab1, CYFRA21-1, and Ab2) and proximity hybridization between Ab1-S1-Fc and Ab2-S2. This caused the release of Ab1-S1-Fc from the modified electrode and the change of S0-MB to a hairpin structure, resulting in a decrease (an increase) of the oxidation peak current of Fc (MB) and an increase of the photocurrent due to the enhancing (inhibiting) effect of MB (Fc) on the photoelectric performance of the Au NPs/PTCDA@C60/ITO electrode. Thus, CYFRA21-1 was detected by the developed EC-PEC dual-mode sensing platform sensitively, and the linear response ranges of 0.001-40 ng/mL with a detection limit of 0.3 pg/mL for the EC technique and 0.0001-4 ng/mL with a detection limit of 0.03 pg/mL for the PEC method were obtained. Furthermore, by changing the specific antibodies of disease-related biomarkers, the developed dual-mode biosensing platform could be readily extended to detect other antigens, implying its great potential applications in biological analysis and early disease diagnosis.
Collapse
Affiliation(s)
- Qingqing Zhang
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, P. R. China
| | - Yamin Fu
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, P. R. China
| | - Ke Xiao
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, P. R. China
| | - Cuicui Du
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, P. R. China
| | - Xiaohua Zhang
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, P. R. China
| | - Jinhua Chen
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, P. R. China
| |
Collapse
|
18
|
Li H, Zhao Y, Yue ME, Jie G. Signal-off photoelectrochemical biosensing platform based on hybridization chain-doped manganese porphyrin quenching on CdSe signal coupling with cyclic amplification for thrombin detection. J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2020.114803] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
19
|
Click chemistry reaction-triggered DNA walker amplification coupled with hyperbranched DNA nanostructure for versatile fluorescence detection and drug delivery to cancer cells. Mikrochim Acta 2020; 187:625. [DOI: 10.1007/s00604-020-04580-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2020] [Accepted: 09/29/2020] [Indexed: 12/16/2022]
|
20
|
Deng H, Chai Y, Yuan R, Yuan Y. In Situ Formation of Multifunctional DNA Nanospheres for a Sensitive and Accurate Dual-Mode Biosensor for Photoelectrochemical and Electrochemical Assay. Anal Chem 2020; 92:8364-8370. [DOI: 10.1021/acs.analchem.0c00918] [Citation(s) in RCA: 39] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Affiliation(s)
- Hanmei Deng
- Chongqing Engineering Laboratory of Nanomaterials & Sensor Technologies, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, China
| | - Yaqin Chai
- Chongqing Engineering Laboratory of Nanomaterials & Sensor Technologies, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, China
| | - Ruo Yuan
- Chongqing Engineering Laboratory of Nanomaterials & Sensor Technologies, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, China
| | - Yali Yuan
- Chongqing Engineering Laboratory of Nanomaterials & Sensor Technologies, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, China
| |
Collapse
|
21
|
Huang L, Tao H, Zhao S, Yang K, Cao QY, Lan M. A Tetraphenylethylene-Based Aggregation-Induced Emission Probe for Fluorescence Turn-on Detection of Lipopolysaccharide in Injectable Water with Sensitivity Down to Picomolar. Ind Eng Chem Res 2020. [DOI: 10.1021/acs.iecr.0c01408] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Affiliation(s)
- Li Huang
- Key Laboratory of Hunan Province for Water Environment and Agriculture Product Safety, College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, P. R. China
| | - Hui Tao
- Department of Chemistry, Nanchang University, Nanchang 330031, P. R. China
| | - Shaojing Zhao
- Key Laboratory of Hunan Province for Water Environment and Agriculture Product Safety, College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, P. R. China
| | - Ke Yang
- Key Laboratory of Hunan Province for Water Environment and Agriculture Product Safety, College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, P. R. China
| | - Qian-Yong Cao
- Department of Chemistry, Nanchang University, Nanchang 330031, P. R. China
| | - Minhuan Lan
- Key Laboratory of Hunan Province for Water Environment and Agriculture Product Safety, College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, P. R. China
- Shenzhen Research Institute of Central South University, Shenzhen 518057, P. R. China
| |
Collapse
|
22
|
Guan T, He J, Liu D, Liang Z, Shu B, Chen Y, Liu Y, Shen X, Li X, Sun Y, Lei H. Open Surface Droplet Microfluidic Magnetosensor for Microcystin-LR Monitoring in Reservoir. Anal Chem 2020; 92:3409-3416. [PMID: 31948225 DOI: 10.1021/acs.analchem.9b05516] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Establishing rapid, simple, and in situ detection of microcystin-LR (MC-LR) in drinking water sources is of significant importance for human health. To ease the situation that current methods cannot address, an open surface droplet microfluidic magnetosensor was designed and validated to quantify MC-LR in reservoir water, which is capable of (1) MC-LR isolation via MC-LR antibody-conjugated magnetic beads, (2) parallel and multistep analytical procedures in 15-array power-free and reusable active droplet microfluidic chips, (3) immunoassay incubation and fluorescence excitation within a miniaturized multifunctional 3D-printing optosensing accessory, and (4) signal read-out and data analysis by a user-friendly Android app. The proposed smartphone-based fluorimetric magnetosensor exhibited a low limit of detection of 1.2 × 10-5 μg/L in the range of 10-4 μg/L to 100 μg/L. This integrated and high throughput platform was utilized to draw an MC-LR contamination map for six reservoirs distributed in the Pearl River delta, Guangdong Province. It promises to be a simple and successful quantification method for MC-LR field detection, bringing many benefits to rapid on-site screening.
Collapse
Affiliation(s)
- Tian Guan
- Key Laboratory of Food Quality and Safety of Guangdong Province, College of Food Science , South China Agricultural University , Guangzhou 510642 , China.,Guangdong Laboratory for Lingnan Modern Agriculture , Guangzhou 510642 , China
| | - Jianfei He
- Key Laboratory of Food Quality and Safety of Guangdong Province, College of Food Science , South China Agricultural University , Guangzhou 510642 , China
| | - Dayu Liu
- Department of Laboratory Medicine, Guangzhou First People's Hospital , Guangzhou Medical University , Guangzhou 510180 , China
| | - Zaoqing Liang
- Key Laboratory of Food Quality and Safety of Guangdong Province, College of Food Science , South China Agricultural University , Guangzhou 510642 , China
| | - Bowen Shu
- Department of Laboratory Medicine, Guangzhou First People's Hospital , Guangzhou Medical University , Guangzhou 510180 , China
| | - Yiping Chen
- College of Food Science and Technology , Huazhong Agricultural University , Wuhan , 430070 , China
| | - Yingju Liu
- Key Laboratory of Food Quality and Safety of Guangdong Province, College of Food Science , South China Agricultural University , Guangzhou 510642 , China
| | - Xing Shen
- Key Laboratory of Food Quality and Safety of Guangdong Province, College of Food Science , South China Agricultural University , Guangzhou 510642 , China
| | - Xiangmei Li
- Key Laboratory of Food Quality and Safety of Guangdong Province, College of Food Science , South China Agricultural University , Guangzhou 510642 , China
| | - Yuanming Sun
- Key Laboratory of Food Quality and Safety of Guangdong Province, College of Food Science , South China Agricultural University , Guangzhou 510642 , China
| | - Hongtao Lei
- Key Laboratory of Food Quality and Safety of Guangdong Province, College of Food Science , South China Agricultural University , Guangzhou 510642 , China.,Guangdong Laboratory for Lingnan Modern Agriculture , Guangzhou 510642 , China
| |
Collapse
|