1
|
Xu H, Wu X, Liu Q, Yang C, Shen M, Wang Y, Liu S, Zhao S, Xiao T, Sun M, Ding Z, Bao J, Chen M, Gao M. A Universal Strategy for Enhancing the Circulating miRNAs' Detection Performance of Rolling Circle Amplification by Using a Dual-Terminal Stem-Loop Padlock. ACS NANO 2024; 18:436-450. [PMID: 38149638 PMCID: PMC10786163 DOI: 10.1021/acsnano.3c07721] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2023] [Revised: 12/15/2023] [Accepted: 12/20/2023] [Indexed: 12/28/2023]
Abstract
Rolling circle amplification (RCA) is one of the most promising nucleic acid detection technologies and has been widely used in the molecular diagnosis of disease. Padlock probes are often used to form circular templates, which are the core of RCA. However, RCA often suffers from insufficient specificity and sensitivity. Here we report a reconstruction strategy for conventional padlock probes to promote their overall performance in nucleic acid detection while maintaining probe functions uncompromised. When two rationally designed stem-loops were strategically placed at the two terminals of linear padlock probes, the specificity of target recognition was enhanced and the negative signal was significantly delayed. Our design achieved the best single-base discrimination compared with other structures and over a 1000-fold higher sensitivity than that of the conventional padlock probe, validating the effectiveness of this reconstruction. In addition, the underlying mechanisms of our design were elucidated through molecular dynamics simulations, and the versatility was validated with longer and shorter padlocks targeting the same target, as well as five additional targets (four miRNAs and dengue virus - 2 RNA mimic (DENV-2)). Finally, clinical applicability in multiplex detection was demonstrated by testing real plasma samples. Our exploration of the structures of nucleic acids provided another perspective for developing high-performance detection systems, improving the efficacy of practical detection strategies, and advancing clinical diagnostic research.
Collapse
Affiliation(s)
- Hanqing Xu
- Department
of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, P. R. China
| | - Xianlan Wu
- Department
of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, P. R. China
| | - Qian Liu
- Department
of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, P. R. China
| | - Cheng Yang
- Department
of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, P. R. China
| | - Man Shen
- Department
of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, P. R. China
| | - Yingran Wang
- Department
of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, P. R. China
| | - Shuai Liu
- Department
of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, P. R. China
| | - Shuang Zhao
- Department
of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, P. R. China
| | - Ting Xiao
- Department
of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, P. R. China
| | - Minghui Sun
- Department
of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, P. R. China
| | - Zishan Ding
- Department
of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, P. R. China
| | - Jing Bao
- Department
of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, P. R. China
| | - Ming Chen
- Department
of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, P. R. China
- College
of Pharmacy and Laboratory Medicine, Third
Military Medical University (Army Medical University), 30 Gaotanyan, Shapingba District, Chongqing 400038, P. R. China
| | - Mingxuan Gao
- Department
of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, P. R. China
| |
Collapse
|
2
|
Jin M, Ding J, Zhou Y, Chen J, Wang Y, Li Z. StratoLAMP: Label-free, multiplex digital loop-mediated isothermal amplification based on visual stratification of precipitate. Proc Natl Acad Sci U S A 2024; 121:e2314030121. [PMID: 38165933 PMCID: PMC10786297 DOI: 10.1073/pnas.2314030121] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Accepted: 12/05/2023] [Indexed: 01/04/2024] Open
Abstract
Multiplex, digital nucleic acid detections have important biomedical applications, but the multiplexity of existing methods is predominantly achieved using fluorescent dyes or probes, making the detection complicated and costly. Here, we present the StratoLAMP for label-free, multiplex digital loop-mediated isothermal amplification based on visual stratification of the precipitate byproduct. The StratoLAMP designates two sets of primers with different concentrations to achieve different precipitate yields when amplifying different nucleic acid targets. In the detection, deep learning image analysis is used to stratify the precipitate within each droplet and determine the encapsulated targets for nucleic acid quantification. We investigated the effect of the amplification reagents and process on the precipitate generation and optimized the assay conditions. We then implemented a deep-learning image analysis pipeline for droplet detection, achieving an overall accuracy of 94.3%. In the application, the StratoLAMP successfully achieved the simultaneous quantification of two nucleic acid targets with high accuracy. By eliminating the need for fluorescence, StratoLAMP represents a unique concept toward label-free, multiplex nucleic acid assays and an analytical tool with great cost-effectiveness.
Collapse
Affiliation(s)
- Meichi Jin
- Department of Biomedical Engineering, Medical School, Shenzhen University, Shenzhen518060, China
| | - Jingyi Ding
- Department of Biomedical Engineering, Medical School, Shenzhen University, Shenzhen518060, China
| | - Yu Zhou
- Department of Biomedical Engineering, Medical School, Shenzhen University, Shenzhen518060, China
- Smart Medical Imaging, Learning and Engineering Lab, Department of Biomedical Engineering, Medical School, Shenzhen University, Shenzhen518060, China
| | - Jiazhao Chen
- Department of Biomedical Engineering, Medical School, Shenzhen University, Shenzhen518060, China
- Smart Medical Imaging, Learning and Engineering Lab, Department of Biomedical Engineering, Medical School, Shenzhen University, Shenzhen518060, China
| | - Yi Wang
- Department of Biomedical Engineering, Medical School, Shenzhen University, Shenzhen518060, China
- Smart Medical Imaging, Learning and Engineering Lab, Department of Biomedical Engineering, Medical School, Shenzhen University, Shenzhen518060, China
| | - Zida Li
- Department of Biomedical Engineering, Medical School, Shenzhen University, Shenzhen518060, China
- Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, Medical School, Shenzhen University, Shenzhen518060, China
| |
Collapse
|
3
|
Wang H, Wang H, Huang Y, Zhang H, Fu Y, Yang Z, Chen Y, Qiu X, Yu D, Zhang L. Multi-parameter surface plasmon resonance instrument for multiple nucleic acid quantitative detection. Biomed Microdevices 2023; 25:24. [PMID: 37418065 DOI: 10.1007/s10544-023-00664-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/14/2023] [Indexed: 07/08/2023]
Abstract
Multiplex nucleic acid assays can simultaneously detect the characteristics of different target nucleic acids in complex mixtures and are used in disease diagnosis, environmental monitoring, and food safety. However, traditional nucleic acid amplification assays have limitations such as complicated operation, long detection time, unstable fluorescent labeling, and mutual interference of multiplex nucleic acids. We developed a real-time, rapid, and label-free surface plasmon resonance (SPR) instrument for multiplex nucleic acid detection. The multiparametric optical system based on total internal reflection solves the multiplex detection problem by cooperating with linear light source, prism, photodetector, and mechanical transmission system. An adaptive threshold consistency correction algorithm is proposed to solve the problem of inconsistent responsiveness of different detection channels and the inability of quantitative comparison. The instrument achieves label-free and amplification-free rapid detection of these biomarkers for miRNA-21 and miRNA-141, which are widely expressed in breast cancer and prostate cancer. The multiplex nucleic acid detection takes 30 min and the biosensor has good repeatability and specificity. The instrument has a limit of detection (LODs) of 50 nM for target oligonucleotides, and the smallest absolute amount of sample that can be detected is about 4 pmol. It provides a simple and efficient point-of-care testing (POCT) detection platform for small molecules such as DNA and miRNA.
Collapse
Affiliation(s)
- Huixiang Wang
- College of Information Science and Technology, Beijing University of Chemical Technology, Beijing, 100029, China
| | - Honggang Wang
- College of Information Science and Technology, Beijing University of Chemical Technology, Beijing, 100029, China
| | - Yafeng Huang
- College of Information Science and Technology, Beijing University of Chemical Technology, Beijing, 100029, China
| | - Hao Zhang
- College of Information Science and Technology, Beijing University of Chemical Technology, Beijing, 100029, China
| | - Yongdong Fu
- College of Information Science and Technology, Beijing University of Chemical Technology, Beijing, 100029, China
| | - Zhenwei Yang
- Core Facility for Protein Research, Institute of Biophysics, Chinese Academy of Sciences, Beijing, 100101, China
| | - Yuanyuan Chen
- Core Facility for Protein Research, Institute of Biophysics, Chinese Academy of Sciences, Beijing, 100101, China
| | - Xianbo Qiu
- College of Information Science and Technology, Beijing University of Chemical Technology, Beijing, 100029, China
| | - Duli Yu
- College of Information Science and Technology, Beijing University of Chemical Technology, Beijing, 100029, China
| | - Lulu Zhang
- College of Information Science and Technology, Beijing University of Chemical Technology, Beijing, 100029, China.
| |
Collapse
|
4
|
Wu K, Fang Q, Zhao Z, Li Z. CoID-LAMP: Color-Encoded, Intelligent Digital LAMP for Multiplex Nucleic Acid Quantification. Anal Chem 2023; 95:5069-5078. [PMID: 36892003 DOI: 10.1021/acs.analchem.2c05665] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/10/2023]
Abstract
Multiplex, digital nucleic acid tests have important biomedical applications, but existing methods mostly use fluorescent probes that are target-specific and difficult to optimize, limiting their widespread applications. Here, we report color-encoded, intelligent digital loop-mediated isothermal amplification (CoID-LAMP) for the coidentification of multiple nucleic acid targets. CoID-LAMP supplements different primer solutions with different dyes, generates primer droplets and sample droplets, and collectively pairs these two types of droplets in a microwell array device to perform LAMP. After imaging, the droplet colors were analyzed to decode the primer information, and the precipitate byproducts within droplets were detected to determine the target occupancy and calculate the concentrations. We first established an image analysis pipeline based on a deep learning algorithm for reliable droplet detection and validated the analytical performance in nucleic acid quantification. We then implemented CoID-LAMP using fluorescent dyes as the coding materials and established an 8-plex digital nucleic acid assay, confirming the reliable coding performance and the capability of multiplex nucleic acid quantification. We further implemented CoID-LAMP using brightfield dyes for a 4-plex assay, suggesting that the assay could be realized solely by brightfield imaging with minimal demand on the optics. Leveraging the advantages of droplet microfluidics in multiplexing and deep learning in intelligent image analysis, CoID-LAMP offers a useful tool for multiplex nucleic acid quantification.
Collapse
Affiliation(s)
- Kai Wu
- Department of Biomedical Engineering, Medical School, Shenzhen University, Shenzhen 518060, China
- Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, Medical School, Shenzhen University, Shenzhen 518060, China
| | - Qi Fang
- Department of Biomedical Engineering, Medical School, Shenzhen University, Shenzhen 518060, China
- Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, Medical School, Shenzhen University, Shenzhen 518060, China
| | - Zhantao Zhao
- Department of Biomedical Engineering, Medical School, Shenzhen University, Shenzhen 518060, China
- Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, Medical School, Shenzhen University, Shenzhen 518060, China
| | - Zida Li
- Department of Biomedical Engineering, Medical School, Shenzhen University, Shenzhen 518060, China
- Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, Medical School, Shenzhen University, Shenzhen 518060, China
| |
Collapse
|
5
|
Cai D, Wang Y, Zou J, Li Z, Huang E, Ouyang X, Que Z, Luo Y, Chen Z, Jiang Y, Zhang G, Wu H, Liu D. Droplet Encoding-Pairing Enabled Multiplexed Digital Loop-Mediated Isothermal Amplification for Simultaneous Quantitative Detection of Multiple Pathogens. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2023; 10:e2205863. [PMID: 36646503 PMCID: PMC9982564 DOI: 10.1002/advs.202205863] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/09/2022] [Revised: 12/06/2022] [Indexed: 06/01/2023]
Abstract
Despite the advantages of digital nucleic acid analysis (DNAA) in terms of sensitivity, precision, and resolution, current DNAA methods commonly suffer a limitation in multiplexing capacity. To address this issue, a droplet encoding-pairing enabled DNAA multiplexing strategy is developed, wherein unique tricolor combinations are deployed to index individual primer droplets. The template droplets and primer droplets are sequentially introduced into a microfluidic chip with a calabash-shaped microwell array and are pairwise trapped and merged in the microwells. Pre-merging and post-amplification image analysis with a machine learning algorithm is used to identify, enumerate, and address the droplets. By incorporating the amplification signals with droplet encoding information, simultaneous quantitative detection of multiple targets is achieved. This strategy allows for the establishment of flexible multiplexed DNAA by simply adjusting the primer droplet library. Its flexibility is demonstrated by establishing two multiplexed (8-plex) droplet digital loop-mediated isothermal amplification (mddLAMP) assays for individually detecting lower respiratory tract infection and urinary tract infection causative pathogens. Clinical sample analysis shows that the microbial detection outcomes of the mddLAMP assays are consistent with those of the conventional assay. This DNAA multiplexing strategy can achieve flexible high-order multiplexing on demand, making it a desirable tool for high-content pathogen detection.
Collapse
Affiliation(s)
- Dongyang Cai
- Department of Laboratory Medicinethe Second Affiliated HospitalSchool of MedicineSouth China University of TechnologyGuangzhou510180China
| | - Yu Wang
- Department of Laboratory Medicinethe Second Affiliated HospitalSchool of MedicineSouth China University of TechnologyGuangzhou510180China
| | - Jingjing Zou
- College of Food Science and EngineeringSouth China University of TechnologyGuangzhou510640China
| | - Zhujun Li
- Department of Laboratory Medicinethe Second Affiliated HospitalSchool of MedicineSouth China University of TechnologyGuangzhou510180China
| | - Enqi Huang
- Department of Laboratory Medicinethe Second Affiliated HospitalSchool of MedicineSouth China University of TechnologyGuangzhou510180China
| | - Xiuyun Ouyang
- College of Food Science and EngineeringSouth China University of TechnologyGuangzhou510640China
| | - Zhiquan Que
- Department of Laboratory Medicinethe Second Affiliated HospitalSchool of MedicineSouth China University of TechnologyGuangzhou510180China
| | - Yanzhang Luo
- Department of Laboratory Medicinethe Second Affiliated HospitalSchool of MedicineSouth China University of TechnologyGuangzhou510180China
| | - Zhenhua Chen
- Department of Laboratory Medicinethe Second Affiliated HospitalSchool of MedicineSouth China University of TechnologyGuangzhou510180China
| | - Yanqing Jiang
- Beijing Baicare Biotechnology Co., LtdBeijing102206China
| | - Guohao Zhang
- Beijing Baicare Biotechnology Co., LtdBeijing102206China
| | - Hongkai Wu
- Department of ChemistryHong Kong University of Science and TechnologyHong KongChina
| | - Dayu Liu
- Department of Laboratory Medicinethe Second Affiliated HospitalSchool of MedicineSouth China University of TechnologyGuangzhou510180China
- Guangdong Engineering Technology Research Center of Microfluidic Chip Medical DiagnosisGuangzhou510180China
- Clinical Molecular Medicine and Molecular Diagnosis Key Laboratory of Guangdong ProvinceGuangzhou510180China
| |
Collapse
|
6
|
Advances in improvement strategies of digital nucleic acid amplification for pathogen detection. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116568] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|