1
|
Dervisevic M, Esser L, Chen Y, Alba M, Prieto-Simon B, Voelcker NH. High-density microneedle array-based wearable electrochemical biosensor for detection of insulin in interstitial fluid. Biosens Bioelectron 2025; 271:116995. [PMID: 39616898 DOI: 10.1016/j.bios.2024.116995] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2024] [Revised: 10/09/2024] [Accepted: 11/24/2024] [Indexed: 01/06/2025]
Abstract
The development of point-of-care wearable devices capable of measuring insulin concentration has the potential to significantly improve diabetes management and life quality of diabetic patients. However, the lack of a suitable point-of-care device for personal use makes regular insulin level measurements challenging, in stark contrast to glucose monitoring. Herein, we report an electrochemical transdermal biosensor that utilizes a high-density polymeric microneedle array (MNA) to detect insulin in interstitial fluid (ISF). The biosensor consists of gold-coated polymeric MNA modified with an insulin-selective aptamer, which was used for extraction and electrochemical quantification of the insulin in ISF. In vitro testing of biosensor, performed in artificial ISF (aISF), showed high selectivity for insulin with a linear response between 0.01 nM and 4 nM (sensitivity of ∼65 Ω nM-1), a range that covers both the physiological and the pathological concentration range. Furthermore, ex vivo extraction and quantification of insulin from mouse skin showed no impact on the biosensor's linear response. As a proof of concept, an MNA-based biosensing platform was utilized for the extraction and quantification of insulin on live mouse skin. In vivo application showed the ability of MNs to reach ISF, extract insulin from ISF, and perform electrochemical measurements sufficient for determining insulin levels in blood and ISF. We believe that our MNA-based biosensing platform based on extraction and quantification of the biomarkers will help move insulin assays from traditional laboratory approaches to personalized point-of-care settings.
Collapse
Affiliation(s)
- Muamer Dervisevic
- Drug Delivery, Disposition and Dynamics, Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, Victoria, 3052, Australia; Melbourne Centre for Nanofabrication, Victorian Node of the Australian National Fabrication Facility, Clayton, Victoria, 3168, Australia
| | - Lars Esser
- Commonwealth Scientific and Industrial Research Organization (CSIRO, Clayton, Victoria, 3168, Australia
| | - Yaping Chen
- Drug Delivery, Disposition and Dynamics, Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, Victoria, 3052, Australia; Melbourne Centre for Nanofabrication, Victorian Node of the Australian National Fabrication Facility, Clayton, Victoria, 3168, Australia
| | - Maria Alba
- Drug Delivery, Disposition and Dynamics, Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, Victoria, 3052, Australia
| | - Beatriz Prieto-Simon
- Institute of Chemical Research of Catalonia, The Barcelona Institute of Science and Technology, Av. Països Catalans, 16, 43007, Tarragona, Spain; ICREA, Pg. Lluís Companys 23, 08010, Barcelona, Spain
| | - Nicolas H Voelcker
- Drug Delivery, Disposition and Dynamics, Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, Victoria, 3052, Australia; Melbourne Centre for Nanofabrication, Victorian Node of the Australian National Fabrication Facility, Clayton, Victoria, 3168, Australia; Materials Science and Engineering, Monash University, Clayton, Victoria, 3168, Australia.
| |
Collapse
|
2
|
Feng X, Yuan R, Liu L, Ding L, Long L, Wang K. Construction of dual-signal output sensing platform for different scene of rapid and sensitive ochratoxin A detection in corn. Talanta 2025; 282:126991. [PMID: 39368334 DOI: 10.1016/j.talanta.2024.126991] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2024] [Revised: 09/12/2024] [Accepted: 10/03/2024] [Indexed: 10/07/2024]
Abstract
Photoelectrochemical (PEC) is a highly sensitive and fast analytical method that can be used at low concentrations, while photoelectrochromic is a simple and low-cost method primarily utilized for high concentration detection. Therefore, we have developed a dual-signal output sensing platform based on both PEC and photoelectrochromism for rapid and sensitive OTA detection. The sensing platform is divided into signal generation (SG) region and signal output (SO) region, which modified with WO3/BiVO4 photoactive nanocomposites and polyaniline (PANI), respectively. By irradiating the SG region, photogenerated electrons are generated and injected into the SO region through the conductive pathway, resulting in a decrease in surface blue polyaniline and a change to green. The smart device can accurately measure the RGB-Green values, enabling the construction of a photochromic visual sensing platform. After immobilizing the OTA aptamer in the SG region, a linear correlation was observed between the concentration of OTA and the RGB-Green value within the range of 20 ng/L ∼250 μg/L. The detection limit was determined to be 8.33 ng/L (S/N = 3). Furthermore, for a more sensitive OTA detection, a PEC sensing platform was developed utilizing the SG region as a photoanode, exhibiting a linear correlation in the range of 2 pg/L∼300 μg/L with a detection limit of 0.8 pg/L (S/N = 3). The detection of these two modes under the requirement of the international standard for the maximum limit realizes the sensitive OTA detection. The RGB-Green is verified to PEC signal, which improves the detection accuracy. The sensing platform has several advantages and is suitable for various application scenarios.
Collapse
Affiliation(s)
- Xujing Feng
- School of Chemistry and Chemical Engineering, Jiangsu University, Zhenjiang, 212013, PR China
| | - Ruishuang Yuan
- School of Chemistry and Chemical Engineering, Jiangsu University, Zhenjiang, 212013, PR China
| | - Liqi Liu
- School of Chemistry and Chemical Engineering, Jiangsu University, Zhenjiang, 212013, PR China
| | - Lijun Ding
- School of Chemistry and Chemical Engineering, Jiangsu University, Zhenjiang, 212013, PR China; Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, OE, School of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, PR China
| | - Lingliang Long
- School of Chemistry and Chemical Engineering, Jiangsu University, Zhenjiang, 212013, PR China
| | - Kun Wang
- School of Chemistry and Chemical Engineering, Jiangsu University, Zhenjiang, 212013, PR China; Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, OE, School of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, PR China.
| |
Collapse
|
3
|
Nandhakumar P, Sun L, Li Z, Cheung C, Nguyen L, Ding S, Gao W, Zhang L, Wang J. Biomimetic Cell Membrane Layers for the Detection of Insulin and Glucagon. Anal Chem 2024; 96:19812-19821. [PMID: 39620950 DOI: 10.1021/acs.analchem.4c05347] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2024]
Abstract
The growing need for reliable and rapid insulin testing to enhance glycemic management has spurred intensive exploration of new insulin-binding bioreceptors and innovative biosensing platforms for detecting this hormone, along with glucagon, in biological samples. Here, by leveraging the native protein receptors on the HepG2 cell membrane, we construct a simple and chemical-free biomimetic molecular recognition layer for the detection of insulin and glucagon. Unlike traditional affinity sensors, which require lengthy surface modifications on the electrochemical transducers and use of two different capture antibodies to recognize each analyte, this new biomimetic sensing strategy employs a simple drop-casting of a natural cell membrane recognition layer onto the electrochemical transducer. This approach allows for the concurrent capture and detection of both insulin and glucagon. We investigate the presence of insulin and glucagon receptors on the HepG2 cell membrane and demonstrate its multiplexing bioelectronic sensing capabilities through the binding of the captured insulin and glucagon to enzyme-tagged signaling antibodies. This new molecular recognition layer offers highly sensitive simultaneous detection of insulin and glucagon under decentralized conditions, holding considerable promise for the management of diabetes and the development of diverse biomimetic diagnostic platforms.
Collapse
Affiliation(s)
- Ponnusamy Nandhakumar
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California San Diego, La Jolla, California 92093, United States
| | - Lei Sun
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California San Diego, La Jolla, California 92093, United States
| | - Zhengxing Li
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California San Diego, La Jolla, California 92093, United States
| | - Christopher Cheung
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California San Diego, La Jolla, California 92093, United States
| | - Ly Nguyen
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California San Diego, La Jolla, California 92093, United States
| | - Shichao Ding
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California San Diego, La Jolla, California 92093, United States
| | - Weiwei Gao
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California San Diego, La Jolla, California 92093, United States
| | - Liangfang Zhang
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California San Diego, La Jolla, California 92093, United States
| | - Joseph Wang
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California San Diego, La Jolla, California 92093, United States
| |
Collapse
|
4
|
Nandhakumar P, Djassemi O, Raucci A, Chang AY, Cheung C, Dugas Y, Silberman J, Morales-Fermin S, S Sandhu S, Reynoso M, Saha T, Cinti S, Wang J. Simultaneous and Rapid Detection of Glucose and Insulin: Coupling Enzymatic and Aptamer-Based Assays. Anal Chem 2024; 96:18806-18814. [PMID: 39546403 DOI: 10.1021/acs.analchem.4c04289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2024]
Abstract
Diabetes management demands precise monitoring of key biomarkers, particularly insulin (I) and glucose (G). Herein, we present a bioelectronic chip device that enables the simultaneous detection of I and G in biofluids within 2 min. This dual biosensor chip integrates aptamer-based insulin sensing with enzymatic glucose detection on a single platform, employing a four-electrode sensor chip. The insulin voltammetric sensor employs a G-quadraplex methylene-blue-modified aptamer, while the amperometric biocatalytic glucose sensor utilizes a second-generation mediator-based approach. Simultaneous reagent-less sensing of I and G has been achieved by addressing key challenges. These include combining different surface chemistries, assay formats, and detection principles at closely spaced working electrodes and the substantially different concentration levels of the I and G targets. An attractive analytical performance, with no apparent crosstalk, is demonstrated for the simultaneous detection of millimolar G concentrations and picomolar I concentrations in single microliter serum or saliva sample droplets. This dual biosensor offers rapid, cost-effective, and reliable monitoring, addressing the unmet need for integrated multiplexed diabetes biomarker detection in decentralized settings. Such integration of enzymatic and aptamer-based bioassays could greatly expand the scope of decentralized testing in healthcare beyond diabetes care.
Collapse
Affiliation(s)
- Ponnusamy Nandhakumar
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California San Diego, La Jolla, California 92093, United States
| | - Omeed Djassemi
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California San Diego, La Jolla, California 92093, United States
- Shu Chien-Gene Lay Department of Bioengineering, University of California San Diego, La Jolla, California 92093, United States
| | - Ada Raucci
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California San Diego, La Jolla, California 92093, United States
- Department of Pharmacy, University of Naples Federico II, Naples 80131, Italy
| | - An-Yi Chang
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California San Diego, La Jolla, California 92093, United States
| | - Christopher Cheung
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California San Diego, La Jolla, California 92093, United States
| | - Yuma Dugas
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California San Diego, La Jolla, California 92093, United States
| | - Julia Silberman
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California San Diego, La Jolla, California 92093, United States
| | - Sofia Morales-Fermin
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California San Diego, La Jolla, California 92093, United States
| | - Samar S Sandhu
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California San Diego, La Jolla, California 92093, United States
| | - Maria Reynoso
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California San Diego, La Jolla, California 92093, United States
| | - Tamoghna Saha
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California San Diego, La Jolla, California 92093, United States
| | - Stefano Cinti
- Department of Pharmacy, University of Naples Federico II, Naples 80131, Italy
| | - Joseph Wang
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California San Diego, La Jolla, California 92093, United States
| |
Collapse
|
5
|
Austin K, Torres JA, Waters JDV, Balog ERM, Halpern JM, Pantazes RJ. An Orthogonal Workflow of Electrochemical, Computational, and Thermodynamic Methods Reveals Limitations of Using a Literature-Reported Insulin Binding Peptide in Biosensors. ACS OMEGA 2024; 9:39219-39231. [PMID: 39310205 PMCID: PMC11411520 DOI: 10.1021/acsomega.4c06481] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/13/2024] [Revised: 08/23/2024] [Accepted: 08/29/2024] [Indexed: 09/25/2024]
Abstract
Developing a continuous insulin-monitoring biosensor is of great importance for both the cellular biomanufacturing industry and for treating diabetes mellitus. Such a sensor needs to be able to effectively monitor insulin across a range of temperatures and pHs and with varying concentrations of competing analytes. One of the two main components of any biosensor is the recognition element, which is responsible for interacting with the molecule of interest. Prior literature describes an insulin-binding peptide (IBP) that was reported to bind to insulin with a 3 nM affinity. Here, we used orthogonal and complementary electrochemical, computational, and thermodynamic characterization methods to evaluate IBP's appropriateness for use in a biosensor. Unfortunately, all three methods failed to produce evidence of IBP-insulin binding either on surfaces or in solution. This indicates that the binding exhibited in previous reports is likely restricted to a limited set of conditions and that IBP is not a suitable recognition element for a continuous insulin biosensor.
Collapse
Affiliation(s)
- Katherine Austin
- Department
of Chemical Engineering and Bioengineering, University of New Hampshire, Durham, New Hampshire 03824, United States
| | - Jazmine A. Torres
- Department
of Chemical Engineering, Auburn University, Auburn, Alabama 36849, United States
| | - Jeffery D. V. Waters
- School
of Molecular and Physical Sciences, University
of New England, Biddeford, Maine 04005, United States
| | - Eva Rose M. Balog
- School
of Molecular and Physical Sciences, University
of New England, Biddeford, Maine 04005, United States
| | - Jeffrey M. Halpern
- Department
of Chemical Engineering and Bioengineering, University of New Hampshire, Durham, New Hampshire 03824, United States
| | - Robert J. Pantazes
- Department
of Chemical Engineering, Auburn University, Auburn, Alabama 36849, United States
| |
Collapse
|
6
|
Zhou L, Zhu R, Figueroa-Miranda G, Neis M, Offenhäusser A, Mayer D. Ratiometric electrochemical aptasensor with strand displacement for insulin detection in blood samples. Anal Chim Acta 2024; 1317:342823. [PMID: 39029996 DOI: 10.1016/j.aca.2024.342823] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2024] [Revised: 05/30/2024] [Accepted: 06/03/2024] [Indexed: 07/21/2024]
Abstract
BACKGROUND Diabetes patients suffer either from insulin deficiency or resistance with a high risk of severe long-term complications, thus the quantitative assessment of insulin level is highly desired for diabetes surveillance and management. Utilizing insulin-capturing aptamers may facilitate the development of affordable biosensors however, their rigid G-quadruplex structures impair conformational changes of the aptamers and diminish the sensor signals. RESULTS Here we report on a ratiometric, electrochemical insulin aptasensor which is achieved by hybridization of an insulin-capturing aptamer and a partially complementary ssDNA to break the rigid G-quadruplex structures. To improve the durability of the aptasensor, the capturing aptamer was immobilized on gold electrodes via two dithiol-phosphoramidite functional groups while methoxy-polyethylene glycol thiol was used as a blocking molecule. The exposure of the sensor to insulin-containing solutions induced the dissociation of the hybridized DNA accompanied by a conformational rearrangement of the capturing aptamer back into a G-quadruplex structure. The reliability of sensor readout was improved by the adoption of an AND logic gate utilizing anthraquinone and methylene blue redox probes associated to the aptamer and complementary strand, respectively. Our aptasensor possessed an improved detection limit of 0.15 nM in comparison to aptasensors without strand displacement. SIGNIFICANCE The sensor was adapted for detection in real blood and is ready for future PoC diagnostics. The capability of monitoring the insulin level in an affordably manner can improve the treatment for an increasing number of patients in developed and developing nations. The utilization of low-cost and versatile aptamer receptors together with the engineering of ratiometric electrochemical signal recording has the potential to considerably advance the current insulin detection technology toward multi-analyte diabetes sensors.
Collapse
Affiliation(s)
- Lei Zhou
- Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, Jülich, Germany; Faculty I, RWTH Aachen University, Aachen, Germany
| | - Ruifeng Zhu
- Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, Jülich, Germany
| | - Gabriela Figueroa-Miranda
- Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, Jülich, Germany
| | - Marc Neis
- Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, Jülich, Germany
| | - Andreas Offenhäusser
- Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, Jülich, Germany
| | - Dirk Mayer
- Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, Jülich, Germany.
| |
Collapse
|
7
|
Sen P, Zhang Z, Sakib S, Gu J, Li W, Adhikari BR, Motsenyat A, L'Heureux-Hache J, Ang JC, Panesar G, Salena BJ, Yamamura D, Miller MS, Li Y, Soleymani L. High-Precision Viral Detection Using Electrochemical Kinetic Profiling of Aptamer-Antigen Recognition in Clinical Samples and Machine Learning. Angew Chem Int Ed Engl 2024; 63:e202400413. [PMID: 38458987 DOI: 10.1002/anie.202400413] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2024] [Revised: 03/05/2024] [Accepted: 03/08/2024] [Indexed: 03/10/2024]
Abstract
High-precision viral detection at point of need with clinical samples plays a pivotal role in the diagnosis of infectious diseases and the control of a global pandemic. However, the complexity of clinical samples that often contain very low viral concentrations makes it a huge challenge to develop simple diagnostic devices that do not require any sample processing and yet are capable of meeting performance metrics such as very high sensitivity and specificity. Herein we describe a new single-pot and single-step electrochemical method that uses real-time kinetic profiling of the interaction between a high-affinity aptamer and an antigen on a viral surface. This method generates many data points per sample, which when combined with machine learning, can deliver highly accurate test results in a short testing time. We demonstrate this concept using both SARS-CoV-2 and Influenza A viruses as model viruses with specifically engineered high-affinity aptamers. Utilizing this technique to diagnose COVID-19 with 37 real human saliva samples results in a sensitivity and specificity of both 100 % (27 true negatives and 10 true positives, with 0 false negative and 0 false positive), which showcases the superb diagnostic precision of this method.
Collapse
Affiliation(s)
- Payel Sen
- Department of Engineering Physics, McMaster University, Canada
| | - Zijie Zhang
- Department of Biochemistry and Biomedical Sciences, McMaster University, Canada
| | - Sadman Sakib
- Department of Engineering Physics, McMaster University, Canada
| | - Jimmy Gu
- Department of Biochemistry and Biomedical Sciences, McMaster University, Canada
| | - Wantong Li
- Department of Engineering Physics, McMaster University, Canada
| | | | - Ariel Motsenyat
- Department of Integrated Biomedical Engineering and Health Sciences, McMaster University, Canada
| | | | - Jann C Ang
- Department of Biochemistry and Biomedical Sciences, McMaster University, Canada
- McMaster Immunology Research Centre, McMaster University, Canada
- Michael G. DeGroote Institute for Infectious Disease Research, McMaster University, Canada
| | - Gurpreet Panesar
- Department of Biochemistry and Biomedical Sciences, McMaster University, Canada
| | | | - Debora Yamamura
- Michael G. DeGroote Institute for Infectious Disease Research, McMaster University, Canada
- Department of Pathology and Molecular Medicine, McMaster University, Canada
| | - Matthew S Miller
- Department of Biochemistry and Biomedical Sciences, McMaster University, Canada
- McMaster Immunology Research Centre, McMaster University, Canada
- Michael G. DeGroote Institute for Infectious Disease Research, McMaster University, Canada
| | - Yingfu Li
- Department of Biochemistry and Biomedical Sciences, McMaster University, Canada
- Michael G. DeGroote Institute for Infectious Disease Research, McMaster University, Canada
- School of Biomedical Engineering, McMaster University, Canada
| | - Leyla Soleymani
- Department of Engineering Physics, McMaster University, Canada
- Department of Biochemistry and Biomedical Sciences, McMaster University, Canada
- Michael G. DeGroote Institute for Infectious Disease Research, McMaster University, Canada
- School of Biomedical Engineering, McMaster University, Canada
| |
Collapse
|
8
|
Khanwalker M, Hatada M, LaBelle JT, Sode K. Development of an electrochemical impedance spectroscopy immunosensor for insulin monitoring employing pyrroloquinoline quinone as an ingestible redox probe. Biosens Bioelectron 2024; 250:116049. [PMID: 38290381 DOI: 10.1016/j.bios.2024.116049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2023] [Revised: 01/03/2024] [Accepted: 01/17/2024] [Indexed: 02/01/2024]
Abstract
Contemporary electrochemical impedance spectroscopy (EIS)-based biosensors face limitations in their applicability for in vivo measurements, primarily due to the necessity of using a redox probe capable of undergoing oxidation and reduction reactions in solution. Although previous investigations have demonstrated the effectiveness of EIS-based biosensors in detecting various target analytes using potassium ferricyanide as a redox probe, its unsuitability for blood or serum measurements, attributed to its inherent toxicity, poses a significant challenge. In response to this challenge, our study adopted a unique approach, focusing on the use of ingestible materials, by exploring naturally occurring substances within the body, with a specific emphasis on pyrroloquinoline quinone (PQQ). Following an assessment of PQQ's electrochemical attributes, we conducted a comprehensive series of EIS measurements. This involved the thorough characterization of the sensor's evolution, starting from the bare electrode and progressing to the immobilization of antibodies. The sensor's performance was then evaluated through the quantification of insulin concentrations ranging from 1 pM to 100 nM. A single frequency was identified for insulin measurements, offering a pathway for potential in vivo applications by combining PQQ as a redox probe with EIS measurements. This innovative approach holds promise for advancing the field of in vivo biosensing based on the EIS method.
Collapse
Affiliation(s)
- Mukund Khanwalker
- Joint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC27599, USA
| | - Mika Hatada
- Joint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC27599, USA
| | - Jeffery T LaBelle
- Department of Bioengineering, College of Engineering Science and Technology, Grand Canyon University, Phoenix, AZ, AZ85017, USA
| | - Koji Sode
- Joint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC27599, USA.
| |
Collapse
|
9
|
Xiong H, Li P, Cun F, Chen H, Kong J. Methylene-Blue-Encapsulated Metal-Organic-Framework-Based Electrochemical POCT Platform for Multiple Detection of Heavy Metal Ions in Milk. BIOSENSORS 2023; 13:783. [PMID: 37622869 PMCID: PMC10452309 DOI: 10.3390/bios13080783] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Revised: 07/27/2023] [Accepted: 07/31/2023] [Indexed: 08/26/2023]
Abstract
Considering the high risk of heavy metal ions (HMIs) transferring through the food chain and accumulating in milk, a flexible and facile point-of-care testing (POCT) platform is urgently needed for the accurate, sensitive, and highly selective on-site quantification of multiple HMIs in milk. In this work, a cost-effective disk with six screen-printed electrodes (SPEs) was designed for hand-held electrochemical detection. Metal organic frameworks (MOFs) were adopted to amplify and enhance the electrochemical signals of methylene blue (MB). Using differential pulse voltammetry (DPV) methods, low limits of detection for four HMIs (Cd2+, 0.039 ppb; Hg2+, 0.039 ppb; Pb2+, 0.073 ppb; and As3+, 0.022 ppb) were achieved within four minutes. Moreover, the quantitative POCT system was applied to milk samples. The advantages of low cost, ease of on-site implementation, fast response, and accuracy allow for the POCT platform to be used in practical monitoring applications for the quantitation of multiple HMIs in milk samples.
Collapse
Affiliation(s)
| | | | | | - Hui Chen
- Department of Chemistry, Fudan University, Shanghai 200438, China
| | - Jilie Kong
- Department of Chemistry, Fudan University, Shanghai 200438, China
| |
Collapse
|
10
|
Cheng H, Wang Y, Wang Y, Ge L, Liu X, Li F. A visualized sensor based on layered double hydroxides with peroxidase-like activity for sensitive acetylcholinesterase assay. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023. [PMID: 37470116 DOI: 10.1039/d3ay00776f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/21/2023]
Abstract
Acetylcholinesterase (AChE) plays a crucial role in biological neurotransmission. The aberrant expression of AChE is associated with various neurodegenerative diseases. Therefore, it is of great significance to develop a simple and highly sensitive AChE analysis platform. Herein, a simple colorimetric sensor was constructed for sensitive detection of AChE based on the peroxidase-like catalytic activity of Ni/Co layered double hydroxides (Ni/Co LDHs). In this sensor, the fabricated Ni/Co LDHs possess high peroxidase-like activity, enabling rapid catalysis of o-phenylenediamine (OPD) to produce yellow oxOPD in the presence of H2O2. This peroxidase-like activity of Ni/Co LDHs was found to be effectively inhibited by the presence of AChE. It is speculated that the combination of AChE on the outer surface of Ni/Co LDHs through non-covalent interaction may cover the active sites and hinder their adsorption to the substrates, leading to the failure of OPD oxidation. As a result, the yellow color from oxOPD is related to the AChE concentration, enabling the direct AChE assay in an equipment-free manner. In addition, the fabricated Ni/Co LDHs could be modified on a paper surface to obtain a paper-based analytical device for visualized colorimetric detection of AChE. The as-proposed sensor shows high sensitivity to AChE with a detection limit down to 6.6 μU mL-1. Therefore, this naked-eye paper-based sensor is capable of on-site and real-time detection of AChE, and has outstanding application prospects in clinical diagnosis and biomedical fields.
Collapse
Affiliation(s)
- Hao Cheng
- College of Chemistry and Pharmaceutical Sciences, Qingdao Agricultural University, Qingdao 266109, P. R. China.
- College of Plant Health & Medicine, Qingdao Agricultural University, Qingdao 266109, P. R. China
| | - Yuying Wang
- College of Chemistry and Pharmaceutical Sciences, Qingdao Agricultural University, Qingdao 266109, P. R. China.
- College of Plant Health & Medicine, Qingdao Agricultural University, Qingdao 266109, P. R. China
| | - Yue Wang
- College of Chemistry and Pharmaceutical Sciences, Qingdao Agricultural University, Qingdao 266109, P. R. China.
| | - Lei Ge
- College of Chemistry and Pharmaceutical Sciences, Qingdao Agricultural University, Qingdao 266109, P. R. China.
| | - Xiaojuan Liu
- College of Chemistry and Pharmaceutical Sciences, Qingdao Agricultural University, Qingdao 266109, P. R. China.
| | - Feng Li
- College of Chemistry and Pharmaceutical Sciences, Qingdao Agricultural University, Qingdao 266109, P. R. China.
| |
Collapse
|
11
|
Picogram level electrochemical impedimetric immunosensor for monitoring Mycobacterium tuberculosis based on specific and sensitive ESAT-6 monoclonal antibody. Talanta 2022. [DOI: 10.1016/j.talanta.2022.124052] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
12
|
Wang Y, Zhao P, Zhang S, Zhu K, Shangguan X, Liu L, Zhang S. Application of Janus Particles in Point-of-Care Testing. BIOSENSORS 2022; 12:bios12090689. [PMID: 36140074 PMCID: PMC9496037 DOI: 10.3390/bios12090689] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Revised: 08/20/2022] [Accepted: 08/22/2022] [Indexed: 06/01/2023]
Abstract
Janus particles (JPs), named after the two-faced Roman god, are asymmetric particles with different chemical properties or polarities. JPs have been widely used in the biomedical field in recent years, including as drug carriers for targeted controlled drug release and as biosensors for biological imaging and biomarker detection, which is crucial in the early detection and treatment of diseases. In this review, we highlight the most recent advancements made with regard to Janus particles in point-of-care testing (POCT). Firstly, we introduce several commonly used methods for preparing Janus particles. Secondly, we present biomarker detection using JPs based on various detection methods to achieve the goal of POCT. Finally, we discuss the challenges and opportunities for developing Janus particles in POCT. This review will facilitate the development of POCT biosensing devices based on the unique properties of Janus particles.
Collapse
|
13
|
Zhang W, Luo Y, Zhu PH, Ni XL, Redshaw C, Tao Z, Xiao X. Supramolecular Polymeric Material Based on Twisted Cucurbit[14]uril: Sensitive Detection and Removal of Potential Cyanide from Water. ACS APPLIED MATERIALS & INTERFACES 2022; 14:37068-37075. [PMID: 35926157 DOI: 10.1021/acsami.2c10866] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Potassium ferricyanide in an aqueous solution is easily decomposed into highly toxic substances (potassium cyanide and hydrogen cyanide) by light or alkaline action, which poses a major hazard to environmental and human health. Here, a reticulated aggregation-induced emission (AIE) supramolecular polymer material (TPAP-Mb@tQ[14]) was prepared by the supramolecular self-assembly of twisted cucurbit[14]uril (tQ[14]) and a triphenylamine derivative (TPAP-Mb). TPAP-Mb@tQ[14] not only recognizes Fe(CN)63- with sensitive specificity with a limit of detection (LOD) of 1.64 × 10-7 M but can also effectively remove and adsorb Fe(CN)63- from an aqueous solution with a removal rate as high as 97.38%. Meanwhile, an important component of the supramolecular polymer material (tQ[14]) can be reused. Thus, the tQ[14]-based supramolecular assembly has the potential to be used for applications addressing toxic anionic contaminants present in aqueous environments.
Collapse
Affiliation(s)
- Wei Zhang
- Key Laboratory of Macrocyclic and Supramolecular Chemistry of Guizhou Province, Institute of Applied Chemistry, Guizhou University, Guiyang 550025, China
| | - Yang Luo
- Key Laboratory of Macrocyclic and Supramolecular Chemistry of Guizhou Province, Institute of Applied Chemistry, Guizhou University, Guiyang 550025, China
| | - Pan-Hua Zhu
- Key Laboratory of Macrocyclic and Supramolecular Chemistry of Guizhou Province, Institute of Applied Chemistry, Guizhou University, Guiyang 550025, China
| | - Xin-Long Ni
- Key Laboratory of Macrocyclic and Supramolecular Chemistry of Guizhou Province, Institute of Applied Chemistry, Guizhou University, Guiyang 550025, China
| | - Carl Redshaw
- Department of Chemistry, University of Hull, Hull HU6 7RX, UK
| | - Zhu Tao
- Key Laboratory of Macrocyclic and Supramolecular Chemistry of Guizhou Province, Institute of Applied Chemistry, Guizhou University, Guiyang 550025, China
| | - Xin Xiao
- Key Laboratory of Macrocyclic and Supramolecular Chemistry of Guizhou Province, Institute of Applied Chemistry, Guizhou University, Guiyang 550025, China
| |
Collapse
|
14
|
Zhao Y, Song X. An Electrochemical-Based Point-of-Care Testing Methodology for Uric Acid Measurement. JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY 2022; 2022:8555842. [PMID: 35915620 PMCID: PMC9338848 DOI: 10.1155/2022/8555842] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/14/2022] [Revised: 06/23/2022] [Accepted: 06/29/2022] [Indexed: 06/15/2023]
Abstract
Point-of-care technology (POCT) is an important method in clinical testing in the future, which can achieve the purpose of rapid analysis. In this work, we assembled an electrochemical POC sensor for uric acid (UA) by surface modification of a screen-printed electrode. Copper nanowires were used as electrode modifiers to achieve high-performance electrochemical oxidation of UA. This electrochemical sensor can achieve linear detection of UA in the range of 10 μM to 2 mM. The detection limit of the sensor was calculated to be 2 μM. Although the detection performance of this sensor is not competitive with high-performance electrochemical sensors, it has been able to meet the needs of POC detection. At the same time, the sensor has excellent anti-interference performance. It has also been used successfully to test urine and serum samples from healthy and gout patients.
Collapse
Affiliation(s)
- Yuetong Zhao
- Department of Rheumatology and Immunology, The First Hospital of China Medical University, No.155 Nnajing Street, Heping District, Shenyang 110000, Liaoning Province, China
| | - Xia Song
- Department of Operating Room, The First Hospital of China Medical University, No.155 Nnajing Street, Shenyang 110000, Liaoning Province, China
| |
Collapse
|
15
|
Kimura H, Asano R. Strategies to simplify operation procedures for applying labeled antibody-based immunosensors to point-of-care testing. Anal Biochem 2022; 654:114806. [PMID: 35835209 DOI: 10.1016/j.ab.2022.114806] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Revised: 06/12/2022] [Accepted: 07/07/2022] [Indexed: 11/01/2022]
Abstract
Point-of-care testing (POCT) is an ideal testing format for the rapid and on-site detection of analytes in patients, and facilitates disease diagnosis and monitoring. Molecular recognition elements are required for the specific detection of analytes, and biosensors that use antibodies as the molecular recognition elements are called immunosensors. Traditional immunosensors such as sandwich enzyme-linked immunosorbent assay (ELISA) require complicated procedures to form immunocomplexes consisting of detection antibodies, analytes, and capture antibodies. They also require long incubation times, washing procedures, and large and expensive specialized equipment that must be operated by laboratory technicians. Immunosensors for POCT should be systems that use relatively small pieces of equipment and do not require special training. In this review, to help in the construction of immunosensors for POCT, we have summarized the recently reported strategies for simplifying the operation, incubation, and washing procedures. We focused on the optical and electrochemical detection principles of immunosensors, compared the strategies for operation, sensitivity, and detection devices and discussed the ideal system. Combining detection devices that can be fabricated inexpensively and strategies that enable simplification of operation procedures and enhance sensitivities will contribute to the development of immunosensors for POCT.
Collapse
Affiliation(s)
- Hayato Kimura
- Department of Biotechnology and Life Science, Graduate School of Engineering, Tokyo University of Agriculture and Technology, Tokyo, 184-8588, Japan
| | - Ryutaro Asano
- Department of Biotechnology and Life Science, Graduate School of Engineering, Tokyo University of Agriculture and Technology, Tokyo, 184-8588, Japan; Institute of Global Innovation Research, Tokyo University of Agriculture and Technology, Tokyo, 184-8588, Japan.
| |
Collapse
|