1
|
Akamine IR, Garich JV, Gulick DW, Hara SA, Benscoter MA, Kuehn ST, Worrell GA, Raupp GB, Blain Christen JM. Development of a novel, concentric micro-ECoG array enabling simultaneous detection of a single location by multiple electrode sizes. Biomed Phys Eng Express 2024; 10:045040. [PMID: 38744259 DOI: 10.1088/2057-1976/ad4b1c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2023] [Accepted: 05/14/2024] [Indexed: 05/16/2024]
Abstract
Objective.Detection of the epileptogenic zone is critical, especially for patients with drug-resistant epilepsy. Accurately mapping cortical regions exhibiting high activity during spontaneous seizure events while detecting neural activity up to 500 Hz can assist clinicians' surgical decisions and improve patient outcomes.Approach.We designed, fabricated, and tested a novel hybrid, multi-scale micro-electrocorticography (micro-ECoG) array with a unique embedded configuration. This array was compared to a commercially available microelectrode array (Neuronexus) for recording neural activity in rodent sensory cortex elicited by somatosensory evoked potentials and pilocarpine-induced seizures.Main results.Evoked potentials and spatial maps recorded by the multi-scale array ('micros', 'mesos', and 'macros' refering to the relative electrode sizes, 40 micron, 1 mm, and 4 mm respectively) were comparable to the Neuronexus array. The SSEPs recorded with the micros had higher peak amplitudes and greater signal power than those recorded by the larger mesos and macro. Seizure onset events and high-frequency oscillations (∼450 Hz) were detected on the multi-scale, similar to the commercially available array. The micros had greater SNR than the mesos and macro over the 5-1000 Hz frequency range during seizure monitoring. During cortical stimulation experimentation, the mesos successfully elicited motor effects.Significance.Previous studies have compared macro- and microelectrodes for localizing seizure activity in adjacent regions. The multi-scale design validated here is the first to simultaneously measure macro- and microelectrode signals from the same overlapping cortical area. This enables direct comparison of microelectrode recordings to the macroelectrode recordings used in standard neurosurgical practice. Previous studies have also shown that cortical regions generating high-frequency oscillations are at an increased risk for becoming epileptogenic zones. More accurate mapping of these micro seizures may improve surgical outcomes for epilepsy patients.
Collapse
Affiliation(s)
- Ian R Akamine
- Biomedical & Health Systems Engineering, Arizona State University, Tempe, AZ, United States of America
| | - Jonathan V Garich
- Biomedical & Health Systems Engineering, Arizona State University, Tempe, AZ, United States of America
- Division of Engineering, Mayo Clinic, Rochester, MN, United States of America
| | - Daniel W Gulick
- Electrical, Computer, & Energy Engineering, Arizona State University, Tempe, AZ, United States of America
| | - Seth A Hara
- Division of Engineering, Mayo Clinic, Rochester, MN, United States of America
| | - Mark A Benscoter
- Division of Engineering, Mayo Clinic, Rochester, MN, United States of America
| | - Stephen T Kuehn
- Division of Engineering, Mayo Clinic, Rochester, MN, United States of America
| | - Gregory A Worrell
- Department of Neurology, Mayo Clinic, Rochester, MN, United States of America
| | - Gregory B Raupp
- Engineering of Matter, Transport, & Energy, Arizona State University, Tempe, AZ, United States of America
| | - Jennifer M Blain Christen
- Electrical, Computer, & Energy Engineering, Arizona State University, Tempe, AZ, United States of America
| |
Collapse
|
2
|
Bhatia A, Hanna J, Stuart T, Kasper KA, Clausen DM, Gutruf P. Wireless Battery-free and Fully Implantable Organ Interfaces. Chem Rev 2024; 124:2205-2280. [PMID: 38382030 DOI: 10.1021/acs.chemrev.3c00425] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/23/2024]
Abstract
Advances in soft materials, miniaturized electronics, sensors, stimulators, radios, and battery-free power supplies are resulting in a new generation of fully implantable organ interfaces that leverage volumetric reduction and soft mechanics by eliminating electrochemical power storage. This device class offers the ability to provide high-fidelity readouts of physiological processes, enables stimulation, and allows control over organs to realize new therapeutic and diagnostic paradigms. Driven by seamless integration with connected infrastructure, these devices enable personalized digital medicine. Key to advances are carefully designed material, electrophysical, electrochemical, and electromagnetic systems that form implantables with mechanical properties closely matched to the target organ to deliver functionality that supports high-fidelity sensors and stimulators. The elimination of electrochemical power supplies enables control over device operation, anywhere from acute, to lifetimes matching the target subject with physical dimensions that supports imperceptible operation. This review provides a comprehensive overview of the basic building blocks of battery-free organ interfaces and related topics such as implantation, delivery, sterilization, and user acceptance. State of the art examples categorized by organ system and an outlook of interconnection and advanced strategies for computation leveraging the consistent power influx to elevate functionality of this device class over current battery-powered strategies is highlighted.
Collapse
Affiliation(s)
- Aman Bhatia
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - Jessica Hanna
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - Tucker Stuart
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - Kevin Albert Kasper
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - David Marshall Clausen
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - Philipp Gutruf
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
- Department of Electrical and Computer Engineering, The University of Arizona, Tucson, Arizona 85721, United States
- Bio5 Institute, The University of Arizona, Tucson, Arizona 85721, United States
- Neuroscience Graduate Interdisciplinary Program (GIDP), The University of Arizona, Tucson, Arizona 85721, United States
| |
Collapse
|