1
|
Jiang W, Mu Y, Zhao F, Wang P. Advancements in Pediatric Audiological Assessments Using Wideband Acoustic Immittance: A Review. Audiol Res 2024; 14:684-700. [PMID: 39194414 DOI: 10.3390/audiolres14040058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2024] [Revised: 08/04/2024] [Accepted: 08/11/2024] [Indexed: 08/29/2024] Open
Abstract
OBJECTIVES This study's objectives were to explore the potential of wideband acoustic immittance (WAI) as a diagnostic tool, examining its accuracy and efficiency in pediatric audiology. METHODS A narrative review of the contemporary literature was conducted, focusing on studies that assessed the use of WAI in diagnosing pediatric auditory conditions. Key variables such as diagnostic accuracy, efficiency, and clinical outcomes were considered. RESULTS This review highlighted that WAI offers a broader range of test frequencies and more comprehensive diagnostic information compared with traditional tympanometry. The studies indicated that WAI has the potential to improve diagnostic accuracy and efficiency in pediatric audiology. Distinct patterns of wideband absorbance were identified, enabling more detailed and accurate diagnostic evaluations. CONCLUSIONS WAI shows substantial potential as a diagnostic tool in pediatric audiology, offering improvements in diagnostic accuracy and efficiency over traditional methods. While the initial findings are promising, further research is needed to fully understand its applicability and benefits across different pediatric populations. Future studies should aim to validate the clinical utility of WAI to ensure its widespread adoption in pediatric audiological assessments.
Collapse
Affiliation(s)
- Wen Jiang
- Department of Otolaryngology, The Affiliated Hospital of Xuzhou Medical University, Xuzhou 221000, China
- The College of Medical Technology, Xuzhou Medical University, Xuzhou 221000, China
- The Second College of Clinical Medicine, Xuzhou Medical University, Xuzhou 221000, China
- Auditory Engineering Laboratory of Jiangsu Province, Xuzhou 221000, China
| | - Yi Mu
- The College of Medical Technology, Xuzhou Medical University, Xuzhou 221000, China
| | - Fei Zhao
- Centre for SLT and Hearing Sciences, Cardiff School of Sport and Health Sciences, Cardiff Metropolitan University, Cardiff CF5 2YB, UK
| | - Peng Wang
- National Intellectual Property Information Service Center, China University of Mining and Technology, Xuzhou 221000, China
| |
Collapse
|
2
|
Sanches AB, Sanfins MD, Skarzynski PH, Skarżyńska MB, Penatti HC, Donadon C, de Souza IP, da Silva IV, Colella-Santos MF. Wideband Tympanometry and Pressurized Otoacoustic Emissions in Children with Surgical Excision of Palatine and/or Pharyngeal Tonsils. Brain Sci 2024; 14:598. [PMID: 38928598 PMCID: PMC11201830 DOI: 10.3390/brainsci14060598] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2024] [Revised: 06/03/2024] [Accepted: 06/04/2024] [Indexed: 06/28/2024] Open
Abstract
Palatine and pharyngeal tonsil hypertrophy may lead to dysfunction of the auditory tube due to a propensity for infection, potentially giving rise to otitis media. This is a quantitative and longitudinal study, developed from 2019 to 2021, at the State University of Campinas (UNICAMP). The studied sample comprised 15 participants aged 5 to 12 years (mean 7.9 years), 12 male and 3 female, arranged into two groups: children diagnosed with pharyngeal and/or palatine tonsil hypertrophy who were candidates for surgery (G1), and children who were later evaluated after surgery (G2). As part of the test, an otoscopy and measurements of logoaudiometry, pure-tone threshold audiometry, wideband tympanometry (ambient and peak pressure), and otoacoustic emissions (TEOAEs and DPOAEs, both at ambient and peak pressure) were all performed. There were statistically significant differences between phases in pure-tone audiometry, in terms of 226 Hz tympanometry, wideband tympanometry in peak pressure conditions, in the amplitude measurement TEOAEs in both pressure conditions, in DPOAEs in ambient pressure conditions, and in the signal/noise measurement in both pressures in DPOAEs. Overall, it was found that hearing tests were different for subjects with palatine and pharyngeal tonsil hypertrophy compared to the post-surgical group.
Collapse
Affiliation(s)
- Aline Buratti Sanches
- Faculty of Medical Sciences, State University of Campinas, Campinas 13083-887, São Paulo, Brazil; (A.B.S.); (C.D.); (I.P.d.S.); (I.V.d.S.); (M.F.C.-S.)
| | - Milaine Dominici Sanfins
- Speech-Hearing-Language Department, Audiology Discipline, Universidade Federal de São Paulo, São Paulo 04023-062, São Paulo, Brazil
- Department of Teleaudiology and Screening, Institute of Physiology and Pathology of Hearing, 05-830 Kajetany/Warsaw, Poland;
| | - Piotr Henryk Skarzynski
- Department of Teleaudiology and Screening, Institute of Physiology and Pathology of Hearing, 05-830 Kajetany/Warsaw, Poland;
- Department of Otorhinolaryngology Hearing, Center of Hearing and Speech Medincus, 05-830 Kajetany, Poland;
- Department of Clinical Trials, Institute of Sensory Organs, 05-830 Kajetany, Poland
| | - Magdalena Beata Skarżyńska
- Department of Otorhinolaryngology Hearing, Center of Hearing and Speech Medincus, 05-830 Kajetany, Poland;
- Department of Clinical Trials, Institute of Sensory Organs, 05-830 Kajetany, Poland
- Department of Hearing, World Hearing Center, Institute of Physiology and Pathology of Hearing, 05-830 Kajetany, Poland
- Department of Pharmacotherapy and Pharmaceutical Care, Faculty of Pharmacy, Medical University of Warsaw, 02-097 Warsaw, Poland
| | - Henrique Costa Penatti
- Department of Otolaryngology, Ambulatory of Medical Specialties, Santa Bárbara D’Oeste 13450-000, São Paulo, Brazil;
| | - Caroline Donadon
- Faculty of Medical Sciences, State University of Campinas, Campinas 13083-887, São Paulo, Brazil; (A.B.S.); (C.D.); (I.P.d.S.); (I.V.d.S.); (M.F.C.-S.)
| | - Ingrid Pereira de Souza
- Faculty of Medical Sciences, State University of Campinas, Campinas 13083-887, São Paulo, Brazil; (A.B.S.); (C.D.); (I.P.d.S.); (I.V.d.S.); (M.F.C.-S.)
| | - Ingridy Vitoria da Silva
- Faculty of Medical Sciences, State University of Campinas, Campinas 13083-887, São Paulo, Brazil; (A.B.S.); (C.D.); (I.P.d.S.); (I.V.d.S.); (M.F.C.-S.)
| | - Maria Francisca Colella-Santos
- Faculty of Medical Sciences, State University of Campinas, Campinas 13083-887, São Paulo, Brazil; (A.B.S.); (C.D.); (I.P.d.S.); (I.V.d.S.); (M.F.C.-S.)
| |
Collapse
|
3
|
Tsilivigkos C, Vitkos EN, Ferekidis E, Warnecke A. Can Multifrequency Tympanometry Be Used in the Diagnosis of Meniere's Disease? A Systematic Review and Meta-Analysis. J Clin Med 2024; 13:1476. [PMID: 38592318 PMCID: PMC10932169 DOI: 10.3390/jcm13051476] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2024] [Revised: 02/27/2024] [Accepted: 02/28/2024] [Indexed: 04/10/2024] Open
Abstract
(1) Background: Ménière's disease (MD) is a disease of the inner ear, presenting with episodes of vertigo, hearing loss, and tinnitus.The aim of this study is to examine the role of multifrequency tympanometry (MFT) in the diagnosis of MD. (2) Methods: A systematic review of MEDLINE (via PubMed), Scopus, Google Scholar, and the Cochrane Library was performed, aligned with the PRISMA guidelines. Only studies that directly compare ears affected by Ménière's disease with unaffected or control ears were included. Random-effects model meta-analyses were performed. (3) Results: Seven prospective case-control studies reported a total of 899 ears, 282 of which were affected by Ménière's disease (affected ears-AE), 197 unaffected ears in patients with MD (UE), and 420 control ears (CE) in healthy controls. No statistically significant differences between the groups were observed regarding resonant frequency (RF). The pure tone audiometry average of the lower frequencies (PTA basic) was significantly greater in affected ears when compared with unaffected ears. The conductance tympanogram at 2 kHz revealed a statistically significantly greater G width of 2 kHz in the affected ears when compared to both unaffected and control ears, while control ears had a statistically significant lesser G width of 2 kHz compared to both the other two groups. (4) Conclusions: MFT, and specifically G width at 2 kHz, could be an important tool in the diagnosis of MD.
Collapse
Affiliation(s)
- Christos Tsilivigkos
- First Department of Otolaryngology, Hippokration General Hospital, National and Kapodistrian University of Athens, 15772 Athens, Greece;
| | - Evangelos N. Vitkos
- Department of Oral and Maxillofacial Surgery, George Papanikolaou General Hospital, 56429 Thessaloniki, Greece
| | - Eleftherios Ferekidis
- First Department of Otolaryngology, Hippokration General Hospital, National and Kapodistrian University of Athens, 15772 Athens, Greece;
| | - Athanasia Warnecke
- Department of Otorhinolaryngology—Head and Neck Surgery, Hannover Medical School, 30625 Hanover, Germany
- Cluster of Excellence Hearing4all, German Research Foundation, 30625 Hannover, Germany
| |
Collapse
|
4
|
潘 慧, 谢 敏, 刘 波, 肖 红. [Analysis of wideband acoustic immittance measurements in patients with unilateral Ménière's disease]. LIN CHUANG ER BI YAN HOU TOU JING WAI KE ZA ZHI = JOURNAL OF CLINICAL OTORHINOLARYNGOLOGY HEAD AND NECK SURGERY 2023; 37:809-814. [PMID: 37828885 PMCID: PMC10803243 DOI: 10.13201/j.issn.2096-7993.2023.10.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Indexed: 10/14/2023]
Abstract
Objective:To investigate the characteristics of wideband acoustic immittance(WAI) measurements in patients with unilateral Ménière's disease(MD) and evaluate the clinical value of WAI in diagnosis of MD. Methods:WAI was performed in 30 patients with unilateral MD(30 ears for symptomatic and 30 ears for asymptomatic) and in 26 healthy individuals(52 ears)(control group). The WAI measurements, including the frequency first appearing two peaks in energy absorbance(EA) tympanogram, resonance frequency(RF), the peak value of absorbance(PVA), the integral area of absorbance(IAA), EA curve at peak pressure, were analyzed. Results:①The occurrence of two peaks in EA tympanogram in both the MD symptomatic and asymptomatic ear was observed in 27 ears(84.4%), and 38 ears(70.4%) in the control group, with no significant difference in the frequency of first appearing in two peaks onset between the groups(all P>0.05). ②The RF of the MD symptomatic ears was significantly lower than that of the asymptomatic ears(t=-3.544, P=0.001) and that of the control subjects(t=2.084, P=0.041); there was no difference of RF between the MD asymptomatic ears and the control group(P>0.05). ③The PVA were significantly lower in both MD symptomatic(t=4.240, P<0.01) and asymptomatic ears(t=4.202, P=0.001) than in controls. ④The IAA in MD symptomatic(t=3.295, P=0.001) and asymptomatic ears(t=3.193, P=0.003) was significantly lower than in the control group. ⑤Comparison of the EA curve at peak pressure of the three groups: the EAs of MD symptomatic ears were lower than those of the control group at the range of 1 059-2 911 Hz(all P<0.05); the EAs of MD symptomatic ears were lower than those of MD asymptomatic ears within 1 000 Hz and 1 834-2 119 Hz(all P<0.05); the EAs of MD asymptomatic ears were lower than those of the control group at the range of 515-2 748 Hz(all P<0.05). Conclusion:Symptomatic ears in unilateral MD patients show alterations in some WAI measurements compared to asymptomatic ears and/or controls, suggesting that middle ear mechanical fuction of the affected side may be modified due to the endolymphatic hydrops. The clinical significance of WAI needs to be further explored in the context of evaluating MD.
Collapse
Affiliation(s)
- 慧 潘
- 华中科技大学同济医学院附属协和医院耳鼻咽喉头颈外科(武汉,430022)Department of Otorhinolaryngology-Head Neck Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China
| | - 敏 谢
- 华中科技大学同济医学院附属协和医院耳鼻咽喉头颈外科(武汉,430022)Department of Otorhinolaryngology-Head Neck Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China
| | - 波 刘
- 华中科技大学同济医学院附属协和医院耳鼻咽喉头颈外科(武汉,430022)Department of Otorhinolaryngology-Head Neck Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China
| | - 红俊 肖
- 华中科技大学同济医学院附属协和医院耳鼻咽喉头颈外科(武汉,430022)Department of Otorhinolaryngology-Head Neck Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China
| |
Collapse
|
5
|
Li A, Du H, Gao J, Xu Y, Zhao N, Gao S, Xing Y, Qian X, Gao X, Yang Y. Characteristics of large vestibular aqueduct syndrome in wideband acoustic immittance. Front Neurosci 2023; 17:1185033. [PMID: 37304035 PMCID: PMC10248168 DOI: 10.3389/fnins.2023.1185033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Accepted: 05/11/2023] [Indexed: 06/13/2023] Open
Abstract
Objective To describe the characteristics of large vestibular aqueduct syndrome (LVAS) in wideband acoustic immittance (WAI) and to explore whether inner ear deformity has an impact on WAI results. Methods Subjects with typical LVAS (LVAS group) and control subjects with a normal anatomical structure of the inner ear (control group) were screened from pediatric patients with cochlear implants using thin-slice computed tomography (CT) images of the temporal bone. With inflammation of the auditory canal and middle ear excluded by routine ear examination and 226 Hz acoustic immittance, WAI data were acquired. Then, the maximum absorbance as the major observation indicator on the mean tympanogram was compared between the LVAS group and control group, and a descriptive comparison of the mean tympanogram and frequency-absorbance curve at peak pressure was performed between the two groups. Results The LVAS group included 21 cases (38 ears), and the control group included 27 cases (45 ears). All LVAS subjects met the Valvassori criteria, and the VA at the horizontal semicircular canal displayed flared expansion. On the mean tympanogram, the maximum absorbance in the LVAS group (0.542 ± 0.087) was significantly higher than that in the control group (0.455 ± 0.087) (p < 0.001). The tympanogram in the LVAS group showed an overall elevation, and the absorbance at all pressure sampling points was significantly higher than that in the control group (p < 0.001). The frequency-absorbance curve at peak pressure first increased and then decreased in both groups, and the LVAS group showed higher absorbance than the control group in the frequency range below 2,828 Hz. The absorbance at 343-1,124 Hz was significantly different between the two groups (p < 0.001), and 343-1,124 Hz was the major frequency range at which the maximum absorbance on the mean tympanogram increased in the LVAS group. Conclusion Large vestibular aqueduct syndrome (LVAS) shows increased absorbance in low and medium frequency ranges in WAI. The maximum absorbance on the mean tympanogram can serve as a reliable evaluation indicator. Inner ear factors must be considered when middle ear lesions are analyzed by WAI.
Collapse
Affiliation(s)
- Ao Li
- Jiangsu Provincial Key Medical Discipline (Laboratory), Department of Otolaryngology-Head and Neck Surgery, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, China
- Research Institute of Otolaryngology, Nanjing, China
| | - Haoliang Du
- Jiangsu Provincial Key Medical Discipline (Laboratory), Department of Otolaryngology-Head and Neck Surgery, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, China
- Research Institute of Otolaryngology, Nanjing, China
| | - Junyan Gao
- Department of Technical Counseling, Jiangsu Children’s Rehabilitation Research Center, Nanjing, China
| | - Yuqin Xu
- Jiangsu Provincial Key Medical Discipline (Laboratory), Department of Otolaryngology-Head and Neck Surgery, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, China
- Research Institute of Otolaryngology, Nanjing, China
| | - Ning Zhao
- Jiangsu Provincial Key Medical Discipline (Laboratory), Department of Otolaryngology-Head and Neck Surgery, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, China
- Research Institute of Otolaryngology, Nanjing, China
| | - Song Gao
- Jiangsu Provincial Key Medical Discipline (Laboratory), Department of Otolaryngology-Head and Neck Surgery, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, China
- Research Institute of Otolaryngology, Nanjing, China
| | - Yuxuan Xing
- Jiangsu Provincial Key Medical Discipline (Laboratory), Department of Otolaryngology-Head and Neck Surgery, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, China
- Research Institute of Otolaryngology, Nanjing, China
| | - Xiaoyun Qian
- Jiangsu Provincial Key Medical Discipline (Laboratory), Department of Otolaryngology-Head and Neck Surgery, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, China
- Research Institute of Otolaryngology, Nanjing, China
| | - Xia Gao
- Jiangsu Provincial Key Medical Discipline (Laboratory), Department of Otolaryngology-Head and Neck Surgery, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, China
- Research Institute of Otolaryngology, Nanjing, China
| | - Ye Yang
- Jiangsu Provincial Key Medical Discipline (Laboratory), Department of Otolaryngology-Head and Neck Surgery, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, China
- Research Institute of Otolaryngology, Nanjing, China
| |
Collapse
|
6
|
Kose O, Funnell WRJ, Daniel SJ. Vibration Measurements of the Gerbil Eardrum Under Quasi-static Pressure Sweeps. J Assoc Res Otolaryngol 2022; 23:739-750. [PMID: 36100816 PMCID: PMC9789261 DOI: 10.1007/s10162-022-00867-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2021] [Accepted: 08/13/2022] [Indexed: 01/06/2023] Open
Abstract
Tympanometry provides an objective measurement of the status of the middle ear. During tympanometry, the ear-canal pressure is varied, while the response of the ear to sound pressure is measured. The effects of the pressure on the mechanics of the middle ear are not well understood. This study is a continuation of our previous work in which the vibration response of the gerbil eardrum was measured in vivo under quasi-static pressure steps. In this study, we delivered a continuous pressure sweep to the middle ear and measured the vibration response at four locations for six gerbils. Vibrations were recorded using a single-point laser Doppler vibrometer and glass-coated reflective beads (diameter ~ 40 µm) at the umbo and on the mid-manubrium, posterior pars tensa and anterior pars tensa.The vibration magnitudes were similar to those in the previous step-wise pressurization experiments. Most gerbils showed repeatability within less than 10 dB for consecutive cycles. As described in the previous study, as the frequency was increased at ambient pressure, the vibration magnitude on the manubrium increased slightly to a broad peak (referred to as R1) and then decreased until a small peak appeared (referred to as R2), followed by multiple peaks and troughs as the magnitude decreased further. The low-frequency vibration magnitude (at 1 kHz) decreased monotonically as the pressure became more negative except for a dip (about 500 Pa wide) that occurred between - 700 and - 1800 Pa. The lowest overall magnitude was recorded in the dip at mid-manubrium. The vibration magnitudes also decreased as the middle-ear pressure was made more positive and were larger than those at negative pressures. R1 was only visible at negative and small positive middle-ear pressures, while R2 was visible for both positive and negative pressures. R2 split into multiple branches after the middle-ear pressure became slightly positive. No magnitude dip was visible for positive middle-ear pressures.The low-frequency vibration magnitudes at negative middle-ear pressures on the pars tensa were higher than those on the manubrium. R1 was not visible for large negative middle-ear pressures on the pars tensa. R2 appeared as a multi-peak feature on the pars tensa as well, and a higher-frequency branch on the posterior pars tensa appeared as a trough on the anterior pars tensa. The magnitude dip was not present on the pars tensa. The largest overall magnitude was recorded at the R2 peak on the posterior pars tensa.The results of this study expand on the findings of the step-wise pressurization experiments and provide further insight into the evolution of the vibration response of the eardrum under quasi-static pressures.
Collapse
Affiliation(s)
- Orhun Kose
- Department of BioMedical Engineering, McGill University, 3775 rue University, Montréal, QC H3A 2B4 Canada
| | - W. Robert J. Funnell
- Department of BioMedical Engineering, McGill University, 3775 rue University, Montréal, QC H3A 2B4 Canada
- Department of Otolaryngology – Head and Neck Surgery, McGill University, Montréal, Canada
- Department of Pediatric Surgery, McGill University, Montréal, Canada
| | - Sam J. Daniel
- Department of Otolaryngology – Head and Neck Surgery, McGill University, Montréal, Canada
- Department of Pediatric Surgery, McGill University, Montréal, Canada
| |
Collapse
|
7
|
杨 军, 金 玉, 陈 建, 张 青, 段 茂. [To address on the refined and individualized comprehensive evaluation of inner ear function]. LIN CHUANG ER BI YAN HOU TOU JING WAI KE ZA ZHI = JOURNAL OF CLINICAL OTORHINOLARYNGOLOGY, HEAD, AND NECK SURGERY 2022; 36:651-658;664. [PMID: 36036063 PMCID: PMC10127629 DOI: 10.13201/j.issn.2096-7993.2022.09.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 06/06/2022] [Indexed: 06/15/2023]
Abstract
Auditory and vestibular function detection technology is the premise and key to the diagnosis and management for inner ear diseases. Concurrent damage to the auditory and vestibular system occurs in many inner ear diseases. The general points and issues on hearing and vestibular function tests, as well as the clinical significance of refined and individualized comprehensive evaluation of inner ear function are described in this paper.
Collapse
Affiliation(s)
- 军 杨
- 上海交通大学医学院附属新华医院耳鼻咽喉-头颈外科 上海交通大学医学院耳科学研究所 上海耳鼻疾病转化医学重点实验室(上海,200092)Department of Otorhinolaryngology-Head & Neck Surgery, Xinhua Hospital, Shanghai Jiaotong University School of Medicine; Shanghai Jiaotong University School of Medicine Ear Institute; Shanghai Key Laboratory of Translational Medicine on Ear and Nose diseases, Shanghai, 200092, China
| | - 玉莲 金
- 上海交通大学医学院附属新华医院耳鼻咽喉-头颈外科 上海交通大学医学院耳科学研究所 上海耳鼻疾病转化医学重点实验室(上海,200092)Department of Otorhinolaryngology-Head & Neck Surgery, Xinhua Hospital, Shanghai Jiaotong University School of Medicine; Shanghai Jiaotong University School of Medicine Ear Institute; Shanghai Key Laboratory of Translational Medicine on Ear and Nose diseases, Shanghai, 200092, China
| | - 建勇 陈
- 上海交通大学医学院附属新华医院耳鼻咽喉-头颈外科 上海交通大学医学院耳科学研究所 上海耳鼻疾病转化医学重点实验室(上海,200092)Department of Otorhinolaryngology-Head & Neck Surgery, Xinhua Hospital, Shanghai Jiaotong University School of Medicine; Shanghai Jiaotong University School of Medicine Ear Institute; Shanghai Key Laboratory of Translational Medicine on Ear and Nose diseases, Shanghai, 200092, China
| | - 青 张
- 上海交通大学医学院附属新华医院耳鼻咽喉-头颈外科 上海交通大学医学院耳科学研究所 上海耳鼻疾病转化医学重点实验室(上海,200092)Department of Otorhinolaryngology-Head & Neck Surgery, Xinhua Hospital, Shanghai Jiaotong University School of Medicine; Shanghai Jiaotong University School of Medicine Ear Institute; Shanghai Key Laboratory of Translational Medicine on Ear and Nose diseases, Shanghai, 200092, China
| | - 茂利 段
- 瑞典斯德哥尔摩卡罗林斯卡大学医院创伤与修复医学耳鼻咽喉病区Ear Nose and Throat Patient Area, Trauma and Reparative Medicine Theme, Karolinska University Hospital, Stockholm, Sweden
- 瑞典斯德哥尔摩卡罗林斯卡医学院临床科学干预及技术系耳鼻咽喉头颈外科Division of Ear, Nose and Throat Diseases, Department of Clinical Science, Intervention and Technology, Karolinska Institute, Stockholm, Sweden
| |
Collapse
|
8
|
吴 妍, 何 白, 沈 敏, 杨 艳, 金 玉, 张 青, 杨 军, 李 姝. [Characteristics of wideband tympanometry in patients with Ménière's disease based on neutral network]. LIN CHUANG ER BI YAN HOU TOU JING WAI KE ZA ZHI = JOURNAL OF CLINICAL OTORHINOLARYNGOLOGY, HEAD, AND NECK SURGERY 2022; 36:685-690. [PMID: 36036069 PMCID: PMC10127621 DOI: 10.13201/j.issn.2096-7993.2022.09.007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 05/28/2022] [Indexed: 06/13/2023]
Abstract
Objective:To construct a prediction model for Ménière's disease based on neural network and evaluate its prediction ability. Methods:Sixty-four patients with Ménière's disease underwent gadolinium enhanced magnetic resonance imaging of inner ear which showed endolymphatic hydrops. Meanwhile, 40 healthy adults were enrolled as controls. The database of wideband tympanometry of patients and control subjects was analyzed, and the neural network model was established by MATLAB 2021a software. The prediction ability of the model was evaluated by accuracy, positive predictive value, negative predictive value, the Youden index, sensitivity, specificity, receiver operating characteristic curve and area under curve (AUC). Results:A feedforward network model was built with a single hidden layer to predict Ménière's disease with wideband tympanometry. There were 104 features in the input layer, 13 neuron nodes in the hidden layer and 1 output neuron in the output layer. The accuracy of the model was 83.2%, the positive predictive value was 80.7%, the negative predictive value was 84.3%, the sensitivity was 76.5%, the specificity was 83.7%, the Youden index was 0.602, and the AUC was 0.855. Conclusion:Based on neural network, the prediction model of Ménière's disease with high accuracy was constructed according to the results of wideband tympanometry, which provided reference for the diagnose of Ménière's disease.
Collapse
Affiliation(s)
- 妍 吴
- 上海交通大学医学院附属新华医院耳鼻咽喉-头颈外科 上海交通大学医学院耳科学研究所 上海耳鼻疾病转化医学重点实验室(上海,200092)Department of Otorhinolaryngology-Head & Neck Surgery, Xinhua Hospital, Shanghai Jiaotong University School of Medicine; Shanghai Jiaotong University School of Medicine Ear Institute; Shanghai Key Laboratory of Translational Medicine on Ear and Nose diseases, Shanghai, 200092, China
| | - 白慧 何
- 上海交通大学医学院附属新华医院耳鼻咽喉-头颈外科 上海交通大学医学院耳科学研究所 上海耳鼻疾病转化医学重点实验室(上海,200092)Department of Otorhinolaryngology-Head & Neck Surgery, Xinhua Hospital, Shanghai Jiaotong University School of Medicine; Shanghai Jiaotong University School of Medicine Ear Institute; Shanghai Key Laboratory of Translational Medicine on Ear and Nose diseases, Shanghai, 200092, China
| | - 敏 沈
- 上海交通大学医学院附属新华医院耳鼻咽喉-头颈外科 上海交通大学医学院耳科学研究所 上海耳鼻疾病转化医学重点实验室(上海,200092)Department of Otorhinolaryngology-Head & Neck Surgery, Xinhua Hospital, Shanghai Jiaotong University School of Medicine; Shanghai Jiaotong University School of Medicine Ear Institute; Shanghai Key Laboratory of Translational Medicine on Ear and Nose diseases, Shanghai, 200092, China
| | - 艳 杨
- 辽宁省医疗器械检验检测院Liaoning Medical Instrument Inspection and Testing Institute
| | - 玉莲 金
- 上海交通大学医学院附属新华医院耳鼻咽喉-头颈外科 上海交通大学医学院耳科学研究所 上海耳鼻疾病转化医学重点实验室(上海,200092)Department of Otorhinolaryngology-Head & Neck Surgery, Xinhua Hospital, Shanghai Jiaotong University School of Medicine; Shanghai Jiaotong University School of Medicine Ear Institute; Shanghai Key Laboratory of Translational Medicine on Ear and Nose diseases, Shanghai, 200092, China
| | - 青 张
- 上海交通大学医学院附属新华医院耳鼻咽喉-头颈外科 上海交通大学医学院耳科学研究所 上海耳鼻疾病转化医学重点实验室(上海,200092)Department of Otorhinolaryngology-Head & Neck Surgery, Xinhua Hospital, Shanghai Jiaotong University School of Medicine; Shanghai Jiaotong University School of Medicine Ear Institute; Shanghai Key Laboratory of Translational Medicine on Ear and Nose diseases, Shanghai, 200092, China
| | - 军 杨
- 上海交通大学医学院附属新华医院耳鼻咽喉-头颈外科 上海交通大学医学院耳科学研究所 上海耳鼻疾病转化医学重点实验室(上海,200092)Department of Otorhinolaryngology-Head & Neck Surgery, Xinhua Hospital, Shanghai Jiaotong University School of Medicine; Shanghai Jiaotong University School of Medicine Ear Institute; Shanghai Key Laboratory of Translational Medicine on Ear and Nose diseases, Shanghai, 200092, China
| | - 姝娜 李
- 上海交通大学医学院附属新华医院耳鼻咽喉-头颈外科 上海交通大学医学院耳科学研究所 上海耳鼻疾病转化医学重点实验室(上海,200092)Department of Otorhinolaryngology-Head & Neck Surgery, Xinhua Hospital, Shanghai Jiaotong University School of Medicine; Shanghai Jiaotong University School of Medicine Ear Institute; Shanghai Key Laboratory of Translational Medicine on Ear and Nose diseases, Shanghai, 200092, China
| |
Collapse
|
9
|
Meng X, Zhu K, Yue J, Han C. The Role of Wideband Tympanometry in the Diagnosis of Meniere's Disease. Front Neurol 2022; 13:808921. [PMID: 35153998 PMCID: PMC8829324 DOI: 10.3389/fneur.2022.808921] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2021] [Accepted: 01/05/2022] [Indexed: 11/13/2022] Open
Abstract
Meniere's disease (MD) is a clinical syndrome characterized by spontaneous recurrent vertigo, usually accompanied by hearing loss, tinnitus, and aural fullness. The cause of MD remains unclear and is generally considered to be associated with endolymphatic hydrops. Studies showed that patients with MD could have eustachian tube dysfunction (ETD). ETD can disrupt the pressure balance between the middle and inner ear and impair the inner ear's function. In recent years, several studies have attempted to identify MD by using wideband tympanometry (WBT). However, there are limited studies in this area. There is no consensus on how to use WBT to diagnose Meniere's disease. Therefore, we endeavored to conduct a narrative review in this aspect based on the latest research findings. Reduction in resonance frequency and absorbance are characteristic of MD and can identify Meniere's disease. The use of an increase in the integrated area of absorbance as an indicator for identifying MD is controversial. WBT seems to be ineffective as a diagnostic tool during the acute episodes of Meniere's disease. Patients with MD may benefit from WBT. WBT has excellent potential for future use in Meniere's disease. However, further large sample sizes, multicenter studies are needed.
Collapse
Affiliation(s)
- Xiangming Meng
- *Correspondence: Xiangming Meng ; orcid.org/0000-0001-8250-9887
| | | | | | | |
Collapse
|
10
|
刘 洁, 蒋 雯, 林 欢, 李 行, 仝 悦, 刘 稳, 乔 月. [A preliminary study on characteristics of wideband acoustic immittance in patients with Meniere's disease]. LIN CHUANG ER BI YAN HOU TOU JING WAI KE ZA ZHI = JOURNAL OF CLINICAL OTORHINOLARYNGOLOGY, HEAD, AND NECK SURGERY 2021; 35:1068-1072. [PMID: 34886618 PMCID: PMC10127658 DOI: 10.13201/j.issn.2096-7993.2021.12.003] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 08/23/2021] [Indexed: 06/13/2023]
Abstract
Objective:To explore the wideband absorbance characteristics of patients with Meniere's disease(MD). Methods:Wideband acoustic immittance was performed in 52 patients with unilateral Meniere's disease(UMD) and 30 control subjects with normal hearing. All UMD patients underwent pure tone audiometry, 226 Hz acoustic immittance, wideband acoustic immittance, and gadolinium contrast MRI. Sixteen frequency points were chosen to analyze the wideband absorbance at ambient and peak pressure, and the subjects were grouped as UMD group vs. control group and asymptomatic group. The student's t-test was used to compare the absorbance difference between them. Results:Both at peak and ambient pressure, there was a significant difference between the MD group and control group at 1587 Hz, 2000 Hz, 2519 Hz, 3174 Hz, and 4000 Hz; the MD group was lower than the control group(P<0.05); there were no differences between the asymptomatic group and the symptomatic group, there also was a significant difference between the asymptomatic group and control group at 1587-4000 Hz(P<0.05). Conclusion:The wideband absorbance in MD patients was significantly reduced within the frequency range of 1587-4000 Hz, and wideband acoustic immittance seems to be cost-effective in predicting MD.
Collapse
Affiliation(s)
- 洁 刘
- 徐州医科大学医学技术学院(江苏徐州,221004)College of Medical Technology, Xuzhou Medical University, Xuzhou, 221004, China
| | - 雯 蒋
- 徐州医科大学医学技术学院(江苏徐州,221004)College of Medical Technology, Xuzhou Medical University, Xuzhou, 221004, China
- 徐州医科大学第一临床学院First College of Clinical Medicine, Xuzhou Medical University
- 江苏省人工听觉工程实验室Auditory Engineering Laboratory of Jiangsu Province
- 徐州医科大学附属医院耳鼻咽喉科Department of Otolaryngology, Affiliated Hospital of Xuzhou Medical University
| | - 欢 林
- 徐州医科大学医学技术学院(江苏徐州,221004)College of Medical Technology, Xuzhou Medical University, Xuzhou, 221004, China
| | - 行 李
- 徐州医科大学第一临床学院First College of Clinical Medicine, Xuzhou Medical University
| | - 悦 仝
- 徐州医科大学附属医院耳鼻咽喉科Department of Otolaryngology, Affiliated Hospital of Xuzhou Medical University
| | - 稳 刘
- 徐州医科大学附属医院耳鼻咽喉科Department of Otolaryngology, Affiliated Hospital of Xuzhou Medical University
| | - 月华 乔
- 徐州医科大学医学技术学院(江苏徐州,221004)College of Medical Technology, Xuzhou Medical University, Xuzhou, 221004, China
- 徐州医科大学第一临床学院First College of Clinical Medicine, Xuzhou Medical University
- 江苏省人工听觉工程实验室Auditory Engineering Laboratory of Jiangsu Province
- 徐州医科大学附属医院耳鼻咽喉科Department of Otolaryngology, Affiliated Hospital of Xuzhou Medical University
| |
Collapse
|