1
|
Zhang H, Hu Z, Wang J, Xu J, Wang X, Zang G, Qiu J, Wang G. Shear stress regulation of nanoparticle uptake in vascular endothelial cells. Regen Biomater 2023; 10:rbad047. [PMID: 37351014 PMCID: PMC10281962 DOI: 10.1093/rb/rbad047] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Revised: 04/15/2023] [Accepted: 04/23/2023] [Indexed: 06/24/2023] Open
Abstract
Nanoparticles (NPs) hold tremendous targeting potential in cardiovascular disease and regenerative medicine, and exciting clinical applications are coming into light. Vascular endothelial cells (ECs) exposure to different magnitudes and patterns of shear stress (SS) generated by blood flow could engulf NPs in the blood. However, an unclear understanding of the role of SS on NP uptake is hindering the progress in improving the targeting of NP therapies. Here, the temporal and spatial distribution of SS in vascular ECs and the effect of different SS on NP uptake in ECs are highlighted. The mechanism of SS affecting NP uptake through regulating the cellular ROS level, endothelial glycocalyx and membrane fluidity is summarized, and the molecules containing clathrin and caveolin in the engulfment process are elucidated. SS targeting NPs are expected to overcome the current bottlenecks and change the field of targeting nanomedicine. This assessment on how SS affects the cell uptake of NPs and the marginalization of NPs in blood vessels could guide future research in cell biology and vascular targeting drugs.
Collapse
Affiliation(s)
- Hongping Zhang
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400030, China
| | - Ziqiu Hu
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400030, China
| | - Jinxuan Wang
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400030, China
| | - Jianxiong Xu
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400030, China
| | - Xiangxiu Wang
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400030, China
| | - Guangchao Zang
- Lab Teaching & Management Center, Chongqing Medical University, Chongqing 400016, China
| | - Juhui Qiu
- Correspondence address: E-mail: (G.W.); (J.Q.)
| | - Guixue Wang
- Correspondence address: E-mail: (G.W.); (J.Q.)
| |
Collapse
|
2
|
McNamee AP, Simmonds MJ. Red blood cell sublethal damage: haemocompatibility is not the absence of haemolysis. Transfus Med Rev 2023:S0887-7963(23)00013-5. [PMID: 37031086 DOI: 10.1016/j.tmrv.2023.03.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Revised: 03/06/2023] [Accepted: 03/07/2023] [Indexed: 03/17/2023]
Abstract
Blood is a complex fluid owing to its two-phase suspension of formed cellular elements within a protein-rich plasma. Vital to its role in distributing nutrients throughout the circulatory system, the mechanical properties of blood - and particularly red blood cells (RBC)-primarily determine bulk flow characteristics and microcirculatory flux. Various factors impair the physical properties of RBC, including cellular senescence, many diseases, and exposure to mechanical forces. Indeed, the latter is increasingly relevant following the advent of modern life support, such as mechanical circulatory support (MCS), which induce unique interactions between blood and artificial environments that leave blood cells with the signature of aging, albeit accelerated, and crucially underlie various serious complications, including death. Accumulating evidence indicates that these complications appear to be associated with mechanical shear forces present within MCS that are not extreme enough to overtly rupture cells, yet may still induce "sublethal" injury and "fatigue" to vital blood constituents. Impaired RBC physical properties following elevated shear exposure-a hallmark of sublethal injury to blood-are notable and may explain, at least in part, systemic complications and premature mortality associated with MCS. Design of optimal next-generation MCS devices thus requires consideration of biocompatibility and blood-device interactions to minimize potential blood complications and promote clinical success. Presented herein is a contemporary understanding of "blood damage," with emphasis on shear exposures that alter microrheological function but do not overtly destroy cells (ie, sublethal damage). Identification of key cellular factors perturbed by supraphysiological shear exposure are examined, offering potential pathways to enhance design of MCS and blood-contacting medical devices.
Collapse
Affiliation(s)
- Antony P McNamee
- Biorheology Research Laboratory, Menzies Health Institute Queensland, Griffith University, Gold Coast, Australia.
| | - Michael J Simmonds
- Biorheology Research Laboratory, Menzies Health Institute Queensland, Griffith University, Gold Coast, Australia.
| |
Collapse
|
3
|
Alexy T, Detterich J, Connes P, Toth K, Nader E, Kenyeres P, Arriola-Montenegro J, Ulker P, Simmonds MJ. Physical Properties of Blood and their Relationship to Clinical Conditions. Front Physiol 2022; 13:906768. [PMID: 35874542 PMCID: PMC9298661 DOI: 10.3389/fphys.2022.906768] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Accepted: 06/14/2022] [Indexed: 02/03/2023] Open
Abstract
It has been long known that blood health heavily influences optimal physiological function. Abnormalities affecting the physical properties of blood have been implicated in the pathogenesis of various disorders, although the exact mechanistic links between hemorheology and clinical disease manifestations remain poorly understood. Often overlooked in current medical practice, perhaps due to the promises offered in the molecular and genetic era, the physical properties of blood which remain a valuable and definitive indicator of circulatory health and disease. Bridging this gap, the current manuscript provides an introduction to hemorheology. It reviews the properties that dictate bulk and microcirculatory flow by systematically dissecting the biomechanics that determine the non-Newtonian behavior of blood. Specifically, the impact of hematocrit, the mechanical properties and tendency of red blood cells to aggregate, and various plasma factors on blood viscosity will be examined. Subsequently, the manner in which the physical properties of blood influence hemodynamics in health and disease is discussed. Special attention is given to disorders such as sickle cell disease, emphasizing the clinical impact of severely abnormal blood rheology. This review expands into concepts that are highly topical; the relation between mechanical stress and intracellular homeostasis is examined through a contemporary cell-signaling lens. Indeed, accumulating evidence demonstrates that nitric oxide is not only transported by erythrocytes, but is locally produced by mechanically-sensitive enzymes, which appears to have intracellular and potentially extracellular effects. Finally, given the importance of shear forces in the developing field of mechanical circulatory support, we review the role of blood rheology in temporary and durable mechanical circulatory support devices, an increasingly utilized method of life support. This review thus provides a comprehensive overview for interested trainees, scientists, and clinicians.
Collapse
Affiliation(s)
- Tamas Alexy
- Department of Medicine, Division of Cardiology, University of Minnesota, Minneapolis, MN, United States
| | - Jon Detterich
- Department of Pediatrics, Division of Cardiology, Children's Hospital Los Angeles, Keck School of Medicine, University of Southern California, Los Angeles, CA, United States
| | - Philippe Connes
- Laboratory LIBM EA7424, Vascular Biology and Red Blood Cell Team, University of Lyon, Lyon, France
| | - Kalman Toth
- First Department of Medicine, Division of Cardiology, Medical School, University of Pecs, Pecs, Hungary
| | - Elie Nader
- Laboratory LIBM EA7424, Vascular Biology and Red Blood Cell Team, University of Lyon, Lyon, France
| | - Peter Kenyeres
- First Department of Medicine, Division of Cardiology, Medical School, University of Pecs, Pecs, Hungary
| | - Jose Arriola-Montenegro
- Department of Medicine, Division of Cardiology, University of Minnesota, Minneapolis, MN, United States
| | - Pinar Ulker
- Department of Physiology, Akdeniz University, Faculty of Medicine, Antalya, Turkey
| | - Michael J Simmonds
- Biorheology Research Laboratory, Menzies Health Institute Queensland, Griffith University, Brisbane, QLD, Australia
| |
Collapse
|
4
|
Protocol for inspecting blood cell dynamics with a custom ektacytometer-rheometer apparatus. STAR Protoc 2022; 3:101279. [PMID: 35434656 PMCID: PMC9006864 DOI: 10.1016/j.xpro.2022.101279] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
Abstract
Investigating flowing red blood cell (RBC) morphology and orientation is important for elucidating physiology and disease; existing commercially available products are limited to observing cell populations or single cells. In this protocol, we create a custom apparatus that combines coaxial brightfield microscopy with laser diffractometry to inspect near-real-time deformability, morphology, and orientation of flowing RBCs. There are difficulties associated with building optical systems for biological inspection; however, this protocol provides a suitable framework for developing an "ektacytoscope" for studying blood cells. For complete details on the use and execution of this protocol, please refer to McNamee et al. (2020). Protocol to create a custom apparatus for brightfield imaging with coaxial ektacytometry System to facilitate microrheological and biophysical inspection of flowing blood cells Procedure to measure cell deformability, membrane stability, orientation, and aggregation Modular design to enable further developments and optical expansion
Collapse
|
5
|
McNamee AP, Kuck L, Simmonds MJ. Bovine erythrocytes are poor surrogates for human when exposed to sublethal shear stress. Int J Artif Organs 2022; 45:580-587. [PMID: 35531705 DOI: 10.1177/03913988221095581] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Animal blood products are routinely used as surrogates for human tissue in haemocompatibility testing of rotary blood pumps. Bovine blood is particularly attractive due to the animal's large blood volume; however, bovine red blood cells (RBC) differ substantially from those of human, both in biophysical properties and molecular composition. We aimed to determine whether differences also exist in the sensitivity of bovine RBC to a standardised shear stress protocol. Fresh blood from healthy human and bovine donors was exposed to discrete combinations of shear stress using a Couette shearing system, prior to assessment of cellular deformability and mechanical sensitivity. Each sample was exposed to 25 sublethal shear stress combinations (ranging 60-100 Pa × 5-300 s). While bovine RBC exhibited decreased maximal elongation in the absence of conditioning shear, overall deformability at lower shears was ~1.8-fold greater than human. When exposed to any conditioning shear stresses >80 Pa (or 60-70 Pa beyond 5 s), human RBC were significantly rigidified, with greater magnitudes and prolonged exposure compounding this effect. Significantly larger shears were required to rigidify bovine RBC; the most extreme shear condition (100 Pa × 300 s) resulted in approximately three-times more rigidification of human RBC than bovine (137% and 47% respectively). Bovine RBC have superior resilience to mechanical stress when compared with human. Using bovine blood in ex vivo evaluation of rotary blood pumps may thus misrepresent and overestimate device-blood success, and may also have flow-on effects for eventual users. Fresh human blood during early-phase ex vivo testing is thus recommended, given shear-inducing blood pumps are designed for humans - not cattle.
Collapse
Affiliation(s)
- Antony P McNamee
- Biorheology Research Laboratory, Menzies Health Institute Queensland, Griffith University, Gold Coast, QLD, Australia
| | - Lennart Kuck
- Biorheology Research Laboratory, Menzies Health Institute Queensland, Griffith University, Gold Coast, QLD, Australia
| | - Michael J Simmonds
- Biorheology Research Laboratory, Menzies Health Institute Queensland, Griffith University, Gold Coast, QLD, Australia
| |
Collapse
|
6
|
Erythrocyte morphological symmetry analysis to detect sublethal trauma in shear flow. Sci Rep 2021; 11:23566. [PMID: 34876652 PMCID: PMC8651737 DOI: 10.1038/s41598-021-02936-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2021] [Accepted: 11/24/2021] [Indexed: 11/29/2022] Open
Abstract
The viscoelastic properties of red blood cells (RBC) facilitate flexible shape change in response to extrinsic forces. Their viscoelasticity is intrinsically linked to physical properties of the cytosol, cytoskeleton, and membrane-all of which are highly sensitive to supraphysiological shear exposure. Given the need to minimise blood trauma within artificial organs, we observed RBC in supraphysiological shear through direct visualisation to gain understanding of processes leading to blood damage. Using a custom-built counter-rotating shear generator fit to a microscope, healthy red blood cells (RBC) were directly visualised during exposure to different levels of shear (10-60 Pa). To investigate RBC morphology in shear flow, we developed an image analysis method to quantify (a)symmetry of deforming ellipsoidal cells-following RBC identification and centroid detection, cell radius was determined for each angle around the circumference of the cell, and the resultant bimodal distribution (and thus RBC) was symmetrically compared. While traditional indices of RBC deformability (elongation index) remained unaltered in all shear conditions, following ~100 s of exposure to 60 Pa, the frequency of asymmetrical ellipses and RBC fragments/extracellular vesicles significantly increased. These findings indicate RBC structure is sensitive to shear history, where asymmetrical morphology may indicate sublethal blood damage in real-time shear flow.
Collapse
|
7
|
Kuck L, McNamee AP, Simmonds MJ. Impact of small fractions of abnormal erythrocytes on blood rheology. Microvasc Res 2021; 139:104261. [PMID: 34624306 DOI: 10.1016/j.mvr.2021.104261] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2021] [Revised: 09/08/2021] [Accepted: 09/14/2021] [Indexed: 12/13/2022]
Abstract
Red blood cell (RBC) populations are inherently heterogeneous, given mature RBC lack the transcriptional machinery to re-synthesize proteins affected during in vivo aging. Clearance of older, less functional cells thus aids in maintaining consistent hemorheological properties. Scenarios occur, however, where portions of mechanically impaired RBC are re-introduced into blood (e.g., damaged from circulatory support, blood transfusion) and may alter whole blood fluid behavior. Given such perturbations are associated with poor clinical outcomes, determining the tolerable level of abnormal RBC in blood is valuable. Thus, the current study aimed to define the critical threshold of blood fluid properties to re-infused physically-impaired RBC. Cell mechanics of RBC were impaired through membrane cross-linking (glutaraldehyde) or intracellular oxidation (phenazine methosulfate). Mechanically impaired RBC were progressively re-introduced into the native cell population. Negative alterations of cellular deformability and high shear blood viscosity were observed following additions of only 1-5% rigidified RBC. Low-shear blood viscosity was conversely decreased following addition of glutaraldehyde-treated cells; high-resolution microscopy of these mixed cell populations revealed decreased capacity to form reversible aggregates and decreased aggregate size. Mixed RBC populations, when exposed to supraphysiological shear, presented with compounded mechanical impairment. Collectively, key determinants of blood flow behavior are sensitive to mechanical perturbations in RBC, even when only 1-5% of the cell population is affected. Given this fraction is well-below the volume of rigidified RBC introduced during circulatory support or transfusion practice, it is plausible that some adverse events following surgery and/or transfusion may be related to impaired blood fluidity.
Collapse
Affiliation(s)
- Lennart Kuck
- Biorheology Research Laboratory, Menzies Health Institute Queensland, QLD, Australia
| | - Antony P McNamee
- Biorheology Research Laboratory, Menzies Health Institute Queensland, QLD, Australia
| | - Michael J Simmonds
- Biorheology Research Laboratory, Menzies Health Institute Queensland, QLD, Australia.
| |
Collapse
|