Aldelaijan S, Devic S, Bekerat H, Papaconstadopoulos P, Schneider J, Seuntjens J, Cormack RA, Buzurovic IM. Positional and angular tracking of HDR 192 Ir source for brachytherapy quality assurance using radiochromic film dosimetry. Med Phys 2020; 47:6122-6139. [PMID: 33064876 DOI: 10.1002/mp.14540] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Revised: 08/31/2020] [Accepted: 09/25/2020] [Indexed: 11/06/2022] Open
Abstract
PURPOSE To quantify and verify the dosimetric impact of high-dose rate (HDR) source positional uncertainty in brachytherapy, and to introduce a model for three-dimensional (3D) position tracking of the HDR source based on a two-dimensional (2D) measurement. This model has been utilized for the development of a comprehensive source quality assurance (QA) method using radiochromic film (RCF) dosimetry including assessment of different digitization uncertainties. METHODS An algorithm was developed and verified to generate 2D dose maps of the mHDR-V2 192 Ir source (Elekta, Veenendaal, Netherlands) based on the AAPM TG-43 formalism. The limits of the dosimetric error associated with source (0.9 mm diameter) positional uncertainty were evaluated and experimentally verified with EBT3 film measurements for 6F (2.0 mm diameter) and 4F (1.3 mm diameter) size catheters at the surface (4F, 6F) and 10 mm further (4F only). To quantify this uncertainty, a source tracking model was developed to incorporate the unique geometric features of all isodose lines (IDLs) within any given 2D dose map away from the source. The tracking model normalized the dose map to its maximum, then quantified the IDLs using blob analysis based on features such as area, perimeter, weighted centroid, elliptic orientation, and circularity. The Pearson correlation coefficients (PCCs) between these features and source coordinates (x, y, z, θy , θz ) were calculated. To experimentally verify the accuracy of the tracking model, EBT3 film pieces were positioned within a Solid Water® (SW) phantom above and below the source and they were exposed simultaneously. RESULTS The maximum measured dosimetric variations on the 6F and 4F catheter surfaces were 39.8% and 36.1%, respectively. At 10 mm further, the variation reduced to 2.6% for the 4F catheter which is in agreement with the calculations. The source center (x, y) was strongly correlated with the low IDL-weighted centroid (PCC = 0.99), while the distance to source (z) was correlated with the IDL areas (PCC = 0.96) and perimeters (PCC = 0.99). The source orientation θy was correlated with the difference between high and low IDL-weighted centroids (PCC = 0.98), while θz was correlated with the elliptic orientation of the 60-90% IDLs (PCC = 0.97) for a maximum distance of z = 5 mm. Beyond 5 mm, IDL circularity was significant, therefore limiting the determination of θz (PCC ≤ 0.48). The measured positional errors from the film sets above and below the source indicated a source position at the bottom of the catheter (-0.24 ± 0.07 mm). CONCLUSIONS Isodose line features of a 2D dose map away from the HDR source can reveal its spatial coordinates. RCF was shown to be a suitable dosimeter for source tracking and dosimetry. This technique offers a novel source QA method and has the potential to be used for QA of commercial and customized applicators.
Collapse
Affiliation(s)
- Saad Aldelaijan
- Department of Radiation Oncology, Dana Farber/Brigham and Women's Cancer Center, Harvard Medical School, Boston, MA, 02115, USA.,Department of Biomedical Engineering, Montreal Neurological Institute, McGill University, Montréal, QC, H3A 2B4, Canada.,Medical Physics Unit, McGill University, Montréal, QC, H4A 3J1, Canada.,Department of Radiation Oncology, SMBD Jewish General Hospital, Montréal, QC, H3T 1E2, Canada.,Biomedical Physics Department, King Faisal Specialist Hospital & Research Centre, Riyadh, 12713, Saudi Arabia
| | - Slobodan Devic
- Medical Physics Unit, McGill University, Montréal, QC, H4A 3J1, Canada.,Department of Radiation Oncology, SMBD Jewish General Hospital, Montréal, QC, H3T 1E2, Canada
| | - Hamed Bekerat
- Department of Radiation Oncology, SMBD Jewish General Hospital, Montréal, QC, H3T 1E2, Canada
| | | | - James Schneider
- Department of Radiation Oncology, SMBD Jewish General Hospital, Montréal, QC, H3T 1E2, Canada
| | - Jan Seuntjens
- Medical Physics Unit, McGill University, Montréal, QC, H4A 3J1, Canada
| | - Robert A Cormack
- Department of Radiation Oncology, Dana Farber/Brigham and Women's Cancer Center, Harvard Medical School, Boston, MA, 02115, USA
| | - Ivan M Buzurovic
- Department of Radiation Oncology, Dana Farber/Brigham and Women's Cancer Center, Harvard Medical School, Boston, MA, 02115, USA
| |
Collapse
|
2
|
Yogo K, Matsushita A, Tatsuno Y, Shimo T, Hirota S, Nozawa M, Ozawa S, Ishiyama H, Yasuda H, Nagata Y, Hayakawa K. Imaging Cherenkov emission for quality assurance of high-dose-rate brachytherapy. Sci Rep 2020; 10:3572. [PMID: 32108157 PMCID: PMC7046619 DOI: 10.1038/s41598-020-60519-z] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2019] [Accepted: 02/12/2020] [Indexed: 11/26/2022] Open
Abstract
With advances in high-dose-rate (HDR) brachytherapy, the importance of quality assurance (QA) is increasing to ensure safe delivery of the treatment by measuring dose distribution and positioning the source with much closer intervals for highly active sources. However, conventional QA is time-consuming, involving the use of several different measurement tools. Here, we developed simple QA method for HDR brachytherapy based on the imaging of Cherenkov emission and evaluated its performance. Light emission from pure water irradiated by an 192Ir γ-ray source was captured using a charge-coupled device camera. Monte Carlo calculations showed that the observed light was primarily Cherenkov emissions produced by Compton-scattered electrons from the γ-rays. The uncorrected Cherenkov light distribution, which was 5% on average except near the source (within 7 mm from the centre), agreed with the dose distribution calculated using the treatment planning system. The accuracy was attributed to isotropic radiation and short-range Compton electrons. The source positional interval, as measured from the light images, was comparable to the expected intervals, yielding spatial resolution similar to that permitted by conventional film measurements. The method should be highly suitable for quick and easy QA investigations of HDR brachytherapy as it allows simultaneous measurements of dose distribution, source strength, and source position using a single image.
Collapse
Affiliation(s)
- Katsunori Yogo
- Graduate School of Medicine, Nagoya University, 1-1-20 Daiko-minami, Higashi-ku, Nagoya, Aichi, 461-8673, Japan.
- Graduate School of Medical Science, Kitasato University, 1-15-1 Kitasato, Minami, Sagamihara, Kanagawa, 252-0373, Japan.
| | - Akihiro Matsushita
- Graduate School of Medical Science, Kitasato University, 1-15-1 Kitasato, Minami, Sagamihara, Kanagawa, 252-0373, Japan
| | - Yuya Tatsuno
- Graduate School of Medical Science, Kitasato University, 1-15-1 Kitasato, Minami, Sagamihara, Kanagawa, 252-0373, Japan
| | - Takahiro Shimo
- Department of Radiology, Tokyo Nishi Tokushukai Hospital, 3-1-1 Matsubara-cho, Akishima, Tokyo, 196-0003, Japan
| | - Seiko Hirota
- Department of Radiation Biophysics, Research Institute for Radiation Biology and Medicine, Hiroshima University, Kasumi 1-2-3, Minami-ku, Hiroshima, 734-8553, Japan
| | - Marika Nozawa
- School of Medicine, Kitasato University, 1-15-1 Kitasato, Minami, Sagamihara, Kanagawa, 252-0373, Japan
| | - Shuichi Ozawa
- Hiroshima High Precision Radiotherapy Cancer Center, 3-2-2 Futabanosato, Higashi-ku, Hiroshima, 732-0057, Japan
- Department of Radiation Oncology, Hiroshima University Hospital, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8551, Japan
| | - Hiromichi Ishiyama
- Graduate School of Medical Science, Kitasato University, 1-15-1 Kitasato, Minami, Sagamihara, Kanagawa, 252-0373, Japan
- School of Medicine, Kitasato University, 1-15-1 Kitasato, Minami, Sagamihara, Kanagawa, 252-0373, Japan
| | - Hiroshi Yasuda
- Department of Radiation Biophysics, Research Institute for Radiation Biology and Medicine, Hiroshima University, Kasumi 1-2-3, Minami-ku, Hiroshima, 734-8553, Japan
| | - Yasushi Nagata
- Hiroshima High Precision Radiotherapy Cancer Center, 3-2-2 Futabanosato, Higashi-ku, Hiroshima, 732-0057, Japan
- Department of Radiation Oncology, Hiroshima University Hospital, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8551, Japan
| | - Kazushige Hayakawa
- Graduate School of Medical Science, Kitasato University, 1-15-1 Kitasato, Minami, Sagamihara, Kanagawa, 252-0373, Japan
- School of Medicine, Kitasato University, 1-15-1 Kitasato, Minami, Sagamihara, Kanagawa, 252-0373, Japan
| |
Collapse
|