1
|
Klaassen L, Jaarsma-Coes MG, Verbist BM, Vu TK, Marinkovic M, Rasch CR, Luyten GP, Beenakker JWM. Automatic Three-Dimensional Magnetic Resonance-based measurements of tumour prominence and basal diameter for treatment planning of uveal melanoma. Phys Imaging Radiat Oncol 2022; 24:102-110. [PMID: 36386446 PMCID: PMC9649381 DOI: 10.1016/j.phro.2022.11.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Revised: 10/31/2022] [Accepted: 11/01/2022] [Indexed: 11/07/2022] Open
Abstract
Background and Purpose Three-dimensional (3D) Magnetic Resonance Imaging (MRI) is increasingly used to complement conventional two-dimensional ultrasound in the assessment of tumour dimension measurement of uveal melanoma. However, the lack of definitions of the 3D measurements of these tumour dimensions hinders further adaptation of MRI in ocular radiotherapy planning. In this study, we composed 3D MR-based definitions of tumour prominence and basal diameter and compared them to conventional ultrasound. Materials and methods Tumours were delineated on 3DT2 and contrast-enhanced 3DT1 (T1gd) MRI for 25 patients. 3D definitions of tumour prominence and diameter were composed and evaluated automatically on the T1gd and T2 contours. Automatic T1gd measurements were compared to manual MRI measurements, to automatic T2 measurements and to manual ultrasound measurements. Results Prominence measurements were similar for all modalities (median absolute difference 0.3 mm). Automatic T1gd diameter measurements were generally larger than manual MRI, automatic T2 and manual ultrasound measurements (median absolute differences of 0.5, 1.6 and 1.1 mm respectively), mainly due to difficulty defining the axis of the largest diameter. Largest differences between ultrasound and MRI for both prominence and diameter were found in anteriorly located tumours (up to 1.6 and 4.5 mm respectively), for which the tumour extent could not entirely be visualized with ultrasound. Conclusions The proposed 3D definitions for tumour prominence and diameter agreed well with ultrasound measurements for tumours for which the extent was visible on ultrasound. 3D MRI measurements generally provided larger diameter measurements than ultrasound. In anteriorly located tumours, the MRI measurements were considered more accurate than conventional ultrasound.
Collapse
Affiliation(s)
- Lisa Klaassen
- Leiden University Medical Center, Department of Ophthalmology, PO Box 9600, 2300 RC Leiden, the Netherlands
- Leiden University Medical Center, Department of Radiology, PO Box 9600, 2300 RC Leiden, the Netherlands
- Leiden University Medical Center, Department of Radiation Oncology, PO Box 9600, 2300 RC Leiden, the Netherlands
| | - Myriam G. Jaarsma-Coes
- Leiden University Medical Center, Department of Ophthalmology, PO Box 9600, 2300 RC Leiden, the Netherlands
- Leiden University Medical Center, Department of Radiology, PO Box 9600, 2300 RC Leiden, the Netherlands
| | - Berit M. Verbist
- Leiden University Medical Center, Department of Radiology, PO Box 9600, 2300 RC Leiden, the Netherlands
- Holland Particle Therapy Center, PO Box 110, 2600 AC Delft, the Netherlands
| | - T.H. Khanh Vu
- Leiden University Medical Center, Department of Ophthalmology, PO Box 9600, 2300 RC Leiden, the Netherlands
| | - Marina Marinkovic
- Leiden University Medical Center, Department of Ophthalmology, PO Box 9600, 2300 RC Leiden, the Netherlands
| | - Coen R.N. Rasch
- Leiden University Medical Center, Department of Radiation Oncology, PO Box 9600, 2300 RC Leiden, the Netherlands
- Holland Particle Therapy Center, PO Box 110, 2600 AC Delft, the Netherlands
| | - Gregorius P.M. Luyten
- Leiden University Medical Center, Department of Ophthalmology, PO Box 9600, 2300 RC Leiden, the Netherlands
| | - Jan-Willem M. Beenakker
- Leiden University Medical Center, Department of Ophthalmology, PO Box 9600, 2300 RC Leiden, the Netherlands
- Leiden University Medical Center, Department of Radiology, PO Box 9600, 2300 RC Leiden, the Netherlands
- Leiden University Medical Center, Department of Radiation Oncology, PO Box 9600, 2300 RC Leiden, the Netherlands
| |
Collapse
|
2
|
Buonanno F, Conson M, de Almeida Ribeiro C, Oliviero C, Itta F, Liuzzi R, Pacelli R, Cella L, Clemente S. Local tumor control and treatment related toxicity after plaque brachytherapy for uveal melanoma: A systematic review and a data pooled analysis. Radiother Oncol 2021; 166:15-25. [PMID: 34774654 DOI: 10.1016/j.radonc.2021.11.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2021] [Revised: 10/29/2021] [Accepted: 11/02/2021] [Indexed: 01/02/2023]
Abstract
Uveal melanoma (UM) represents the most common primary intraocular tumor, and nowadays eye plaque brachytherapy (EPB) is the most frequently used visual acuity preservation treatment option for small to medium sized UMs. The excellent local tumor control (LTC) rate achieved by EPB may be associated with severe complications and adverse events. Several dosimetric and clinical risk factors for the development of EPB-related ocular morbidity can be identified. However, morbidity predictive models specifically developed for EPB are still scarce. PRISMA methodology was used for the present systematic review of articles indexed in PubMed in the last sixteen years on EPB treatment of UM which aims at determining the major factors affecting local tumor control and ocular morbidities. To our knowledge, for the first time in EPB field, local tumor control probability (TCP) and normal tissue complication probability (NTCP) modelling on pooled clinical outcomes were performed. The analyzed literature (103 studies including 21,263 UM patients) pointed out that Ru-106 EPB provided high local control outcomes while minimizing radiation induced complications. The use of treatment planning systems (TPS) was the most influencing factor for EPB outcomes such as metastasis occurrence, enucleation, and disease specific survival, irrespective of radioactive implant type. TCP and NTCP parameters were successfully extracted for 5-year LTC, cataract and optic neuropathy. In future studies, more consistent recordings of ocular morbidities along with accurate estimation of doses through routine use of TPS are needed to expand and improve the robustness of toxicity risk prediction in EPB.
Collapse
Affiliation(s)
- Francesca Buonanno
- University Federico II, Post Graduate School in Medical Physics, Department of Advanced Biomedical Sciences, Napoli, Italy
| | - Manuel Conson
- University Federico II, Department of Advanced Biomedical Sciences, Napoli, Italy
| | | | - Caterina Oliviero
- University Hospital Federico II, Unit of Medical Physics and Radioprotection, Napoli, Italy
| | - Francesca Itta
- University Federico II, Post Graduate School in Medical Physics, Department of Advanced Biomedical Sciences, Napoli, Italy
| | - Raffaele Liuzzi
- National Research Council (CNR), Institute of Biostructures and Bioimaging, Napoli, Italy
| | - Roberto Pacelli
- University Federico II, Department of Advanced Biomedical Sciences, Napoli, Italy
| | - Laura Cella
- National Research Council (CNR), Institute of Biostructures and Bioimaging, Napoli, Italy.
| | - Stefania Clemente
- University Hospital Federico II, Unit of Medical Physics and Radioprotection, Napoli, Italy
| |
Collapse
|
3
|
Studenski MT, Markoe A, Samuels SE, Correa ZM, Bossart E, Harbour JW. Comprehensive assessment of the effect of eye plaque tilt on tumor dosimetry. Brachytherapy 2021; 20:1289-1295. [PMID: 34193361 DOI: 10.1016/j.brachy.2021.05.013] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2020] [Revised: 04/28/2021] [Accepted: 05/23/2021] [Indexed: 10/21/2022]
Abstract
PURPOSE Tilting of the posterior plaque margin during eye plaque brachytherapy can lead to tumor underdosing and increased risk of local recurrence. We performed a quantitative analysis of the dosimetric effects of plaque tilt as a function of tumor position, basal dimension, height and plaque type using 3D treatment planning software. MATERIALS AND METHODS Posterior and anterior tumors with largest basal dimensions of 6, 12 and 18 mm and heights of 4, 7 and 10 mm were modeled. Both Eye Physics and COMS plaques were simulated and uniformly loaded. Plans were normalized to 85 Gy at the tumor apex. Posterior plaque tilts of 1, 2, 3 and 4 mm were simulated. RESULTS Volumetric coverage is more sensitive to tilt than the area coverage. Wide, flat tumors are more susceptible to tilt. Apical dose changed significantly as a function of tumor height and diameter. No other parameter exhibited significant differences. Posterior tumors are slightly more susceptible to tilt due to the use of notched plaques. Plaque type does not significantly alter the effect of plaque tilt. CONCLUSIONS Wide, flat tumors are the most susceptible to plaque tilt. Tumor location or plaque type does not have a significant effect on dosimetry changes from plaque tilt. Robust clinical procedures such as the use of mattress sutures, pre- and post-implant ultrasound and post-implant dosimetry can all mitigate the risk associated with plaque tilt.
Collapse
Affiliation(s)
- Matthew T Studenski
- Department of Radiation Oncology, Sylvester Comprehensive Cancer Center, University of Miami Miller School of Medicine, Miami, FL.
| | - Arnold Markoe
- Department of Radiation Oncology, Sylvester Comprehensive Cancer Center, University of Miami Miller School of Medicine, Miami, FL
| | - Stuart E Samuels
- Department of Radiation Oncology, Sylvester Comprehensive Cancer Center, University of Miami Miller School of Medicine, Miami, FL
| | - Zelia M Correa
- Bascom Palmer Eye Institute, Sylvester Comprehensive Cancer Center, University of Miami Miller School of Medicine, Miami, FL
| | - Elizabeth Bossart
- Department of Radiation Oncology, Sylvester Comprehensive Cancer Center, University of Miami Miller School of Medicine, Miami, FL
| | - J William Harbour
- Bascom Palmer Eye Institute, Sylvester Comprehensive Cancer Center, University of Miami Miller School of Medicine, Miami, FL
| |
Collapse
|
4
|
Koyuncu N, Reyhancan İA. Dose evaluation of 142Pr radioisotope by Monte Carlo method in eye brachytherapy. Radiat Phys Chem Oxf Engl 1993 2020. [DOI: 10.1016/j.radphyschem.2020.109150] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|