1
|
Kashid SR, Gurram L, Pullan S, Chopra S, Mittal P, Ghadi Y, Dheera A, Scaria L, Kohle S, Kadam S, Ghosh J, Rath S, Gupta S, Mahantshetty U. Clinical outcomes of adaptive intracavitary and interstitial brachytherapy technique in locally advanced cervical cancer: A real-world data. Brachytherapy 2024; 23:407-415. [PMID: 38641455 DOI: 10.1016/j.brachy.2024.03.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2024] [Revised: 03/10/2024] [Accepted: 03/19/2024] [Indexed: 04/21/2024]
Abstract
PURPOSE To evaluate clinical outcomes of CT-based adaptive intracavitary and interstitial brachytherapy (IC followed by IC-ISBT) in locally advanced cervical cancer (LACC) in resource-constrained settings. METHODS AND MATERIALS LACC patients treated with adaptive brachytherapy techniques were analyzed to evaluate treatment characteristics and clinical outcomes. The Kaplan-Meier method was used for survival analysis, and the log-rank test for univariate analysis. RESULTS Out of 141 eligible patients with LACC, 87 (61.7%) patients received external beam radiotherapy (EBRT) in referral hospitals, while 54 (38.3%) were treated at our center. We divided our cohort into two groups: poor EBRT responder group (n = 70 [49.6%]) where IC-ISBT was adapted to achieve optimum tumor doses and OAR optimization group 71 (50.4%) where IC-ISBT was performed to reduce OAR doses. Median HRCTV-D90 dose was 88 Gy (range 70-109 Gy) with median HRCTV volume 33cc (range 15-96). Median D2cc doses to OARs were 90 Gy (range 70-107), 71 Gy (range 55-105) and 70 Gy (range 47-90) to bladder, rectum and sigmoid, respectively. At median follow-up of 32 months, 3-year local control (LC), locoregional control (LRC), disease-free survival (DFS) and overall survival (OS) were 83%, 75%, 64% and 72%, respectively. Subgroup analysis revealed significantly better outcomes for OAR optimization compared to poor EBRT responders, with 3-year LC (95% vs. 70.1%, p < 0.001), LRC (87.3% vs. 62.7%, p < 0.001), DFS (79.2% vs. 49.4%, p < 0.001), and OS (86.2% vs. 57.4%, p < 0.001) CONCLUSION: In resource-constrained settings, implementation of Adaptive IC-ISBT is a viable alternative for optimizing OAR doses in LACC. However proactive approach employing IC-ISBT for tumor dose-escalation from first fraction of BT is warranted for improving LC in poor EBRT responders.
Collapse
Affiliation(s)
- Sheetal R Kashid
- Department of Radiation Oncology, Tata Memorial Hospital, Tata Memorial Centre, Homi Bhabha National Institute, Parel, Mumbai, Maharashtra, India
| | - Lavanya Gurram
- Advanced Radiation Oncology Fellow, Department of Radiation Oncology, CancerCare Manitoba, Canada.
| | - Saritha Pullan
- Department of Radiation Oncology, Tata Memorial Hospital, Tata Memorial Centre, Homi Bhabha National Institute, Parel, Mumbai, Maharashtra, India
| | - Supriya Chopra
- Department of Radiation Oncology, Tata Memorial Hospital, Tata Memorial Centre, Homi Bhabha National Institute, Parel, Mumbai, Maharashtra, India
| | - Prachi Mittal
- Department of Radiation Oncology, Tata Memorial Hospital, Tata Memorial Centre, Homi Bhabha National Institute, Parel, Mumbai, Maharashtra, India
| | - Yogesh Ghadi
- Department of Radiation Physics, Tata Memorial Hospital, Tata Memorial Centre, Homi Bhabha National Institute, Parel, Mumbai, Maharashtra, India
| | - A Dheera
- Department of Radiation Physics, Tata Memorial Hospital, Tata Memorial Centre, Homi Bhabha National Institute, Parel, Mumbai, Maharashtra, India
| | - Libin Scaria
- Department of Radiation Physics, Tata Memorial Hospital, Tata Memorial Centre, Homi Bhabha National Institute, Parel, Mumbai, Maharashtra, India
| | - Satish Kohle
- Department of Radiation Physics, Tata Memorial Hospital, Tata Memorial Centre, Homi Bhabha National Institute, Parel, Mumbai, Maharashtra, India
| | - Sudarshan Kadam
- Department of Radiation Physics, Tata Memorial Hospital, Tata Memorial Centre, Homi Bhabha National Institute, Parel, Mumbai, Maharashtra, India
| | - Jaya Ghosh
- Department of Medical Oncology, Tata Memorial Hospital, Tata Memorial Centre, Homi Bhabha National Institute, Parel, Mumbai, Maharashtra, India
| | - Sushmita Rath
- Department of Medical Oncology, Tata Memorial Hospital, Tata Memorial Centre, Homi Bhabha National Institute, Parel, Mumbai, Maharashtra, India
| | - Sudeep Gupta
- Department of Medical Oncology, Tata Memorial Hospital, Tata Memorial Centre, Homi Bhabha National Institute, Parel, Mumbai, Maharashtra, India
| | - Umesh Mahantshetty
- Homi Bhabha Cancer Hospital, Visakhapatnam, Tata Memorial Centre, Homi Bhabha National Institute, Parel, Mumbai, Maharashtra, India
| |
Collapse
|
2
|
Groszkiewicz A, Foust E, Palestra B, Ertel MC, Boisen M, Sukumvanich P, Smith SK, Smith RP, Vargo JA. Can an in-person hands-on applicator-based teaching session improve trainee knowledge and comfort with complex gynecologic brachytherapy? Brachytherapy 2024; 23:290-300. [PMID: 38519351 DOI: 10.1016/j.brachy.2024.02.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2023] [Revised: 01/21/2024] [Accepted: 02/07/2024] [Indexed: 03/24/2024]
Abstract
INTRODUCTION With the emergence of imaged-based planning and hybrid applicators the complexity of gynecologic brachytherapy has dramatically increased. Despite the known advantages of brachytherapy, notable national declines in utilization of brachytherapy have been documented. Clearly improved education in the sphere of gynecologic brachytherapy is needed. We hypothesize that a hands-on applicator-based training session would improve trainee comfort with gynecologic brachytherapy. METHODS AND MATERIALS An in-person, applicator-based, hands-on training session was held with trainees from both radiation and gynecologic oncology programs. Trainees practiced assembling and handling applicators while receiving instruction on clinical scenarios in which various applicators are used in gynecologic cancer brachytherapy. Pre- and post-session, participants were administered an objective test of 10 pictorial-based case vignettes to quantify ability to select the correct applicator based on the interpretation of T2-weighted MR images. Participants additionally received a subjective survey to quantify comfort and experience with gynecologic brachytherapy using Likert-type question formatting. RESULTS A total of 14 trainees participated. Most common case volume experience was 0-10 intracavitary (57%), 0-10 hybrid (71%), and 0-10 interstitial (71%). Pre-session, the most common answer to comfort level was "not comfortable still learning" for all brachytherapy types, and most common answer to largest gap in knowledge was all facets of brachytherapy. Average case-based test score was 3.5/10 pre-session versus 5.3/10 post-session (p = 0.028). Post-session, all respondents reported improved comfort level with brachytherapy. Post-session, most common answer to largest gap in knowledge was applicator/patient selection, and applicator/patient selection was also the largest area of identified improvement. 100% of participants felt repeating the session in the future would be helpful. CONCLUSIONS Hands-on training with applicators improves both subjective and objective comfort with gynecologic brachytherapy. With 100% of participants requesting to implement this session into resident training, we suggest national opportunities might exist to expand educational processes and improve utilization of complex gynecologic brachytherapy in practice.
Collapse
Affiliation(s)
| | - Emily Foust
- Department of Radiation Oncology, University of Pittsburgh School of Medicine, Pittsburgh, PA
| | - Brett Palestra
- Department of Radiation Oncology, University of Pittsburgh School of Medicine, Pittsburgh, PA
| | - Michelle C Ertel
- Department of Gynecologic Oncology, University of Pittsburgh Medical Center, Pittsburgh PA
| | - Michelle Boisen
- Department of Gynecologic Oncology, University of Pittsburgh Medical Center, Pittsburgh PA
| | - Paniti Sukumvanich
- Department of Gynecologic Oncology, University of Pittsburgh Medical Center, Pittsburgh PA
| | - Shannon Kroskie Smith
- Department of Radiation Oncology, University of Pittsburgh School of Medicine, Pittsburgh, PA
| | - Ryan P Smith
- Department of Radiation Oncology, University of Pittsburgh School of Medicine, Pittsburgh, PA
| | - John A Vargo
- Department of Radiation Oncology, University of Pittsburgh School of Medicine, Pittsburgh, PA.
| |
Collapse
|
3
|
Cobussen A, Petric P, Wulff CN, Buus S, Spejlborg H, Nielsen SK, Traberg A, Meisner B, Hokland S, Lindegaard JC. Clinical outcomes using a 3D printed tandem-needle-template and the EMBRACE-II planning aims for image guided adaptive brachytherapy in locally advanced cervical cancer. Acta Oncol 2023; 62:1470-1478. [PMID: 37594195 DOI: 10.1080/0284186x.2023.2246642] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Accepted: 08/01/2023] [Indexed: 08/19/2023]
Abstract
BACKGROUND Extensive local disease or narrow vagina may compromise brachytherapy (BT) in patients with cervical cancer. This is the first study to analyze long-term outcomes of using 3D printed vaginal tandem-needle templates (3DP TNT) for transvaginal insertion of needles in parallel (P) or parallel and oblique (P&O) direction to the tandem. MATERIAL AND METHODS All patients treated with BT using 3DP TNT from 2015-2020 were included. Decision to use a 3DP TNT and preplanning were made after 4-5 weeks of external beam radiotherapy, based on gynecological examination and MRI with a tandem-ring applicator in situ. The TNT was 3D-printed in house consisting of a circular template with P&O holes for guidance of plastic needles and a shaft fitting the uterine tandem. Thus, the radioactive source was never in direct contact with the 3DP TNT. The TNT was 3D printed in a standard or personalized configuration. Planning aims were based on the Embrace II protocol. RESULTS 101 patients (median age of 63 years) were included: 49 with P needles only and 52 with P&O needles. Personalized TNT was used in 19 patients in the P&O group. Performance status (WHO) was > 0 in 48%. FIGO2018 stage III-IV was present in 77%. T-score at diagnosis and BT was 9.1 and 6.3 respectively, with a significantly higher T-score in the P&O compared to P group. The mean high-risk CTV D90 was 93 Gy with no significant difference between the two groups. Three-year local control rates were 85%, 95%, 75% for the overall, P- and P&O group respectively and 68%, 80% and 56% for cancer specific survival. Grade ≥3 treatment related complications were observed in 10 (10%) patients. CONCLUSIONS 3DP TNT for BT in cervical cancer provides successful management of very extensive local disease and/or unfavorable anatomy with the possibility for treatment individualization.
Collapse
Affiliation(s)
- Anne Cobussen
- Department of Oncology, Aarhus University Hospital, Denmark
- Department of Radiation Oncology, MAASTRO clinic, the Netherlands
| | - Primoz Petric
- Department of Oncology, Aarhus University Hospital, Denmark
- Department of Radiation Oncology, Zürich University Hospital, Switzerland
| | | | - Simon Buus
- Department of Oncology, Aarhus University Hospital, Denmark
| | | | | | - Anders Traberg
- Department of Oncology, Aarhus University Hospital, Denmark
| | - Bjarne Meisner
- Department of Oncology, Aarhus University Hospital, Denmark
| | | | | |
Collapse
|
4
|
Zhang YH, Martin S, Liu H, Todor D, Sohn JJ, Quinn B, Francis LE, Roach M, Fields EC. Utilizing a novel hybrid brachytherapy technique FINITO (Freehand Interstitial Needles in addition to Tandem and Ovoid) for locally advanced cervical cancer. Brachytherapy 2023; 22:746-752. [PMID: 37722989 DOI: 10.1016/j.brachy.2023.06.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2022] [Revised: 05/31/2023] [Accepted: 06/06/2023] [Indexed: 09/20/2023]
Abstract
PURPOSE We aimed to assess the clinical feasibility and advantages of using a novel hybrid brachytherapy technique by placing Freehand Interstitial Needles in addition to the Tandem and Ovoid applicator (FINITO) for the treatment of locally advanced cervical cancer (LAC). METHODS AND MATERIALS A retrospective analysis was performed on two cohorts of patients with LACC treated at our institution: 29 patients in the FINITO group and 17 patients in the control group using T&O only approach. Clinical outcomes of interest included local control (LC), progression-free survival (PFS), overall survival (OS), and rates of acute and late toxicities. Kaplan-Meier methodology was used to estimate OS, PFS, and LC. Wilcoxon signed-rank test was used to compare the median values for dosimetry parameters. A p-value of ≤ 0.05 was considered statistically significant. All statistical analyses were performed using RStudio. RESULTS At a median of 2 years there was no difference in rates of OS, PFS or LC between the FINITO and the control group of patients. The 2-year OS, PFS, and LC for the FINITO group were 59% (95% CI 34%-100%), 58% (95% CI 38%-89%), and 84% (95% CI 69%-100%), respectively. Late toxicities were significantly lower in the FINITO group for both gastrointestinal and genitourinary symptoms (p = 0.001 and 0.01, respectively) as compared to the T&O group. CONCLUSION Based on the equivalent LC rate and lower toxicity profile, our FINITO technique appears to be an excellent alternative to the standard intracavitary brachytherapy in patients with advanced disease, especially in resource-limited settings.
Collapse
Affiliation(s)
- Yue H Zhang
- Department of Radiation Oncology, Virginia Commonwealth University Health System, Richmond, VA
| | - Sara Martin
- Department of Radiation Oncology, Virginia Commonwealth University Health System, Richmond, VA
| | - Han Liu
- Department of Radiation Oncology, Virginia Commonwealth University Health System, Richmond, VA
| | - Dorin Todor
- Department of Radiation Oncology, Virginia Commonwealth University Health System, Richmond, VA
| | - James J Sohn
- Department of Radiation Oncology, Northwestern University Feinberg School of Medicine, Chicago, IL
| | - Bridget Quinn
- Department of Radiation Oncology, Virginia Commonwealth University Health System, Richmond, VA
| | - Louise E Francis
- Department of Radiation Oncology, Virginia Commonwealth University Health System, Richmond, VA
| | - Melinda Roach
- Department of Radiation Oncology, Virginia Commonwealth University Health System, Richmond, VA
| | - Emma C Fields
- Department of Radiation Oncology, Virginia Commonwealth University Health System, Richmond, VA.
| |
Collapse
|
5
|
Lee VWY, Yip WWL, Tang SYK, Leung MPH, Kwan KKK, Liu ACH, Chan VNY, Wu JWS, Cheng JNS, Chiang CL, Ho-Fun Lee V. Efficacy and feasibility of 3D printed redesigned Venezia™ applicator for treating advanced cervix and recurrent endometrial cancer. Phys Med 2023; 114:103150. [PMID: 37757501 DOI: 10.1016/j.ejmp.2023.103150] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Revised: 08/19/2023] [Accepted: 09/22/2023] [Indexed: 09/29/2023] Open
Abstract
PURPOSE Venezia™ is an interstitial brachytherapy applicator for treating advanced cervical and vaginal vault recurrent cancer. However, there are limitations that lead to suboptimal target coverage. 3D printing introduction allows the redesign of Venezia™ for bulky and irregular-shaped tumors. METHODS This study first describes three new designs included: 1) add-on needles template allowed for an extra layer of straight and oblique needles, 2) redesigned vaginal cap so straight and oblique needles can be used together and 3) redesigned central tube allowed vaginal vault interstitial needle insertion. Drawbacks to original Venezia™ and rationale for using these new designs were discussed. Dosimetric analysis by comparing the original Venezia™ with new design for 10 cases in Oncentra treatment planning system v4.5 (Elekta, Stockholm, Sweden) to observe the dose differences in gross tumor volume (GTV), high risk clinical target volume (HRCTV), intermediate clinical target volume (IRCTV) and organs at risk. RESULTS For the dosimetric comparison, there were statistically significantly increased median minimal dose to 98% (D98%) of GTV, 90% (D90%) of HRCTV, and IRCTV for the new design with p-value of 0.008, 0.005 and 0.0018, respectively. Comparing the physical dose of D98% of GTV, D90% of HRCTV, and IRCTV when using the new design, it averagely increased by 11.7%, 8.0%, 19.4%, respectively per fraction. CONCLUSIONS Dosimetric comparison revealed the new designs increased the dose to GTV, HRCTV and IRCTV and fulfilled the dose constraints of bladder, rectum and sigmoid. The 3D printed new design is biocompatible, inexpensive and can be patient specific.
Collapse
Affiliation(s)
- Venus W Y Lee
- Department of Clinical Oncology, Tuen Mun Hospital, Hong Kong, China.
| | - Winnie W L Yip
- Department of Clinical Oncology, Tuen Mun Hospital, Hong Kong, China
| | - Steven Y K Tang
- Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong, China
| | - Mike P H Leung
- Department of Prosthetic and Orthotic, Tuen Mun Hospital, Hong Kong, China
| | - Keith K K Kwan
- Department of Clinical Oncology, Tuen Mun Hospital, Hong Kong, China
| | - Alex C H Liu
- Department of Radiation Therapy, Cancer and Blood Service, Auckland City Hospital, Te Whatu Ora - Health New Zealand, New Zealand
| | | | - Jenna W S Wu
- Department of Clinical Oncology, Tuen Mun Hospital, Hong Kong, China
| | - Jean N S Cheng
- Department of Clinical Oncology, Tuen Mun Hospital, Hong Kong, China
| | - Chi-Leung Chiang
- Department of Clinical Oncology, School of Clinical Medicine, LKS Faculty of Medicine, The University of Hong Kong, Hong Kong, China; Clinical Oncology Center, The University of Hong Kong-Shenzhen Hospital, Shenzhen, China
| | - Victor Ho-Fun Lee
- Department of Clinical Oncology, School of Clinical Medicine, LKS Faculty of Medicine, The University of Hong Kong, Hong Kong, China; Clinical Oncology Center, The University of Hong Kong-Shenzhen Hospital, Shenzhen, China.
| |
Collapse
|
6
|
Song S, Han D, Zhang N, Mao Z, Guo X, Cheng G. The MRI-guided two adaptive brachytherapy fractions versus one adaptive brachytherapy fraction in one application for the cervical cancer: a retrospective study. Radiat Oncol 2023; 18:46. [PMID: 36879287 PMCID: PMC9990264 DOI: 10.1186/s13014-023-02237-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Accepted: 02/23/2023] [Indexed: 03/08/2023] Open
Abstract
PURPOSE This study retrospectively compared the clinical and toxicity outcomes for the cervical cancer of the MRI-guided two adaptive brachytherapy (IGABT) fractions versus one IGABT fraction in one application. METHODS One hundred and twenty patients with cervical cancer received external beam radiotherapy combined with or without concurrent chemotherapy, which was followed by the IGABT. The IGABT in 63 patients had one IGABT in each application (Arm 1), while in the other 57 patients, at least one treatment was two continuous IGABT every other day in one application (Arm 2). Clinical outcomes including overall survival (OS), cancer specific survival (CSS), progression free survival (PFS), local control (LC) were analyzed. Brachytherapy-related toxicities were evaluated, which included pain, dizziness, nausea/vomiting, fever/infection, blood loss during the removal of applicator and needles, the deep venous thrombosis, and other acute toxicities. The Common Terminology Criteria for Adverse Events (CTC-AE 5.0) was used to evaluate the incidence and severity of toxicities of the urinary system, lower digestive system, and reproduction system. Kaplan-Meier and the Log-rank test were used to analyze the clinical outcomes. RESULTS The median follow-up time of the patients in Arm 1 and Arm 2 was 23.5 and 12.0 months, respectively. The overall treatment time was significantly shorter in Arm 2 than Arm 1 (60 vs. 64 d; P = 0.017). The OS, CSS, PFS, and LC in Arm1 and Arm 2 was 77.8% vs. 86.0% (P = 0.632), 77.8% vs. 87.7% (P = 0.821), 68.3% vs. 70.2% (P = 0.207), and 92.1% vs. 94.7% (P = 0.583), respectively. The highest NRS of the pain during brachytherapy waiting period (2.22 ± 1.84 vs. 3.02 ± 1.65; P < 0.001) and at the time of the removal of the applicator (4.69 ± 1.49 vs. 5.30 ± 1.18; P < 0.001) in the patients who received one hybrid intracavitary and interstitial brachytherapy (IC/ISBT) in one application and two continuous IC/ISBT every other day in one application were significantly different. So far four patients with grade 3 late toxicities have been reported. CONCLUSIONS The findings of this study demonstrated that the two continuous IGABT every other day in one application is a logistically applicable, safe, and effective treatment strategy that could shorten the overall treatment time and reduce the medical cost, comparing with the one IGABT in one application.
Collapse
Affiliation(s)
- Shanshan Song
- Department of Radiation Oncology, China-Japan Union Hospital of Jilin University, No.126 Xiantai Street, Changchun, China
| | - Dongmei Han
- Department of Radiation Oncology, China-Japan Union Hospital of Jilin University, No.126 Xiantai Street, Changchun, China
| | - Ning Zhang
- Department of Radiation Oncology, China-Japan Union Hospital of Jilin University, No.126 Xiantai Street, Changchun, China
| | - Zhuang Mao
- Department of Radiation Oncology, China-Japan Union Hospital of Jilin University, No.126 Xiantai Street, Changchun, China
| | - Xin Guo
- Department of Radiation Oncology, China-Japan Union Hospital of Jilin University, No.126 Xiantai Street, Changchun, China
| | - Guanghui Cheng
- Department of Radiation Oncology, China-Japan Union Hospital of Jilin University, No.126 Xiantai Street, Changchun, China.
| |
Collapse
|
7
|
Li X, Huang J, Rahimi R, Zhao H, Kunz J, Suneja G, Su FC. A novel approach for Venezia ovoid commissioning with a comprehensive analysis of source positions in high-dose-rate brachytherapy. Brachytherapy 2023; 22:93-100. [PMID: 36266202 DOI: 10.1016/j.brachy.2022.08.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2022] [Revised: 07/22/2022] [Accepted: 08/29/2022] [Indexed: 02/04/2023]
Abstract
PURPOSE The lunar design of a Venezia ovoid makes commissioning of the applicator very challenging with traditional autoradiography. In this study, we propose a novel solution to ovoid commissioning and a quality assurance (QA) workflow to effectively assess the entire source path. METHODS AND MATERIALS A two-step commissioning process, using electron radiation and radiochromic films, was developed to verify the most distal source position. The ovoid was first attached to a film and was irradiated with a 12 MeV linac beam. This process was repeated on a separate, unexposed film, followed by irradiating it with a HDR source at the most distal position. Two lengths, including the ovoid thickness and the distance between the irradiated spot and the ovoid's outer surface, were obtained from the films' intensity maps. The offset value was calculated from the subtraction of the two measured lengths. Besides acquiring the offset, a source positional simulator (SPS) and a series of planar x-rays from two orthogonal orientations were used to characterize source movement within the ovoid. RESULTS Compared to x-ray-based autoradiography, the electron exposure significantly improved the ovoid's visibility on film. Our approach did not use surrogate, which further improved measurement outcomes by decreasing inherent uncertainties. The SPS results suggested the source movement was complex within the cervicovaginal area, but it was predictable with the proposed QA workflow. CONCLUSION We introduced a novel, surrogate-free method to commission the Venezia ovoid, which facilitated a manual applicator reconstruction. Additionally, we recommended QA multiple source positions to safely use the ovoid in clinical settings.
Collapse
Affiliation(s)
- Xing Li
- University of Utah, Department of Radiation Oncology, Salt Lake City, UT.
| | - Jessica Huang
- University of Utah, Department of Radiation Oncology, Salt Lake City, UT
| | | | - Hui Zhao
- University of Utah, Department of Radiation Oncology, Salt Lake City, UT
| | - Jeremy Kunz
- University of Utah, Department of Radiation Oncology, Salt Lake City, UT
| | - Gita Suneja
- University of Utah, Department of Radiation Oncology, Salt Lake City, UT
| | - Fan-Chi Su
- University of Utah, Department of Radiation Oncology, Salt Lake City, UT
| |
Collapse
|
8
|
Shiao JC, Holt DE, Stuhr K, Schubert L, Robin T, Fisher CM. The Kelowna template for combined intracavitary and interstitial brachytherapy for gynecologic malignancies: Design, application, treatment planning, dosimetric and treatment outcomes. Brachytherapy 2022; 21:823-832. [PMID: 36192312 DOI: 10.1016/j.brachy.2022.04.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Revised: 03/31/2022] [Accepted: 04/04/2022] [Indexed: 12/14/2022]
Abstract
PURPOSE We report the feasibility, experience, and early outcomes of the combined intracavitary and interstitial dedicated applicator using the Kelowna GYN template (Varian, Palo Alto, CA). METHODS AND MATERIALS The Kelowna GYN template is CT compatible and used for the treatment of gynecologic cancers. In cases with patients that have an intact uterus, a modified applicator system using the Kelowna GYN template and a 3D printed adapter piece allows for compatibility with an intrautaerine tandem. RESULTS We reviewed the treatment course of 23 patients comprising of 86 fractions of HDR treatment. Median D90 for cervical tumors (n = 7) was 82.4 Gy (range 77.7-92.6); for postoperative cervical tumors (n = 2) was 73.9 Gy (range 72.0-5.8); for vaginal tumors (n = 4) was 85.8 Gy (range 79.8-88.1); for recurrent endometrial (n = 10) was 86.9 Gy (range 74.8-103.2). Median EQD2 D2cc for bladder was 72.4 Gy (range 47.7-99.4), for rectum was 61.2 Gy (range 52.4-80.6), and for sigmoid colon of 50.5 Gy (44.3-66.9). At a median follow-up of 12 months, 2 patients had a local recurrence. Two patients had distant recurrence: one with carcinomatosis at 6 months, and one with pulmonary metastases at 3 months. No patients had late grade three toxicities. CONCLUSIONS Our single institutional experience supports the use of the Kelowna template as a robust system as a combined IC-IS applicator resulting in versatile and reproducible implants for a variety of gynecologic malignancies.
Collapse
Affiliation(s)
- Jay C Shiao
- Department of Radiation Oncology, University of Colorado Cancer Center, Aurora, CO
| | | | - Kelly Stuhr
- Department of Radiation Oncology, University of Colorado Cancer Center, Aurora, CO
| | - Leah Schubert
- Department of Radiation Oncology, University of Colorado Cancer Center, Aurora, CO
| | - Tyler Robin
- Department of Radiation Oncology, University of Colorado Cancer Center, Aurora, CO
| | - Christine M Fisher
- Department of Radiation Oncology, University of Colorado Cancer Center, Aurora, CO.
| |
Collapse
|
9
|
Rogowski P, Rottler M, Walter F, Saicic S, Niyazi M, Well J, Nierer L, Trillsch F, Burges A, Mahner S, Belka C, Corradini S. Clinical outcome of combined intracavitary / interstitial brachytherapy using a hybrid applicator in locally advanced cervical cancer. Gynecol Oncol 2022; 166:576-581. [PMID: 35764443 DOI: 10.1016/j.ygyno.2022.06.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Revised: 06/14/2022] [Accepted: 06/20/2022] [Indexed: 11/16/2022]
Abstract
OBJECTIVE The aim of this study was to evaluate the clinical outcome in locally advanced cervical cancer (LACC) after image-guided adaptive brachytherapy (IGABT) with combined intracavitary and interstitial (IC/IS) techniques using the hybrid Venezia applicator (Elekta AB, Sweden). METHODS LACC patients (UICC Stage IIB - IVB) treated with radiochemotherapy followed by IGABT with the hybrid IC/IS Venezia applicator at a single institution were retrospectively analyzed. Treatment comprised EBRT of the pelvis with 45 Gy and concomitant weekly cisplatin chemotherapy (40 mg/m2) followed by MRI-based IGABT. Dosimetry, oncological outcome and toxicity were investigated. RESULTS Forty-six patients underwent a total of 184 fractions of IGABT between 2017 and 2020. Median follow-up was 24 months. Combined IC/IS techniques were used in 40 patients (87%). The median HRCTV volume was 31.2 cm3 and the median HRCTV D90% was 92.3 Gy (EQD210). The median D2cm3 was 74.8 Gy for bladder, 57.9 Gy for rectum, 60.0 Gy for sigmoid and 52.2 Gy for bowel (EQD23). The 3-yr actuarial rates were 97.6% for local control, 97.6% for pelvic control, 59.9% for distant metastasis-free survival and 81.6% for overall survival. The crude rate for G2 and G3 late toxicity was 21.7% and 4.3%. CONCLUSIONS IGABT with the hybrid Venezia applicator and a pronounced use of a combined IC/IS technique achieved high target doses, while maintaining low doses to organs at risk, leading to excellent local control and overall survival rates with acceptable toxicity.
Collapse
Affiliation(s)
- Paul Rogowski
- Department of Radiation Oncology, University Hospital, LMU Munich, Germany.
| | - Maya Rottler
- Department of Radiation Oncology, University Hospital, LMU Munich, Germany
| | - Franziska Walter
- Department of Radiation Oncology, University Hospital, LMU Munich, Germany
| | - Stefan Saicic
- Department of Radiation Oncology, University Hospital, LMU Munich, Germany
| | - Maximilian Niyazi
- Department of Radiation Oncology, University Hospital, LMU Munich, Germany
| | - Justus Well
- Department of Radiation Oncology, University Hospital, LMU Munich, Germany
| | - Lukas Nierer
- Department of Radiation Oncology, University Hospital, LMU Munich, Germany
| | - Fabian Trillsch
- Department of Obstetrics and Gynecology, University Hospital, LMU Munich, Germany
| | - Alexander Burges
- Department of Obstetrics and Gynecology, University Hospital, LMU Munich, Germany
| | - Sven Mahner
- Department of Obstetrics and Gynecology, University Hospital, LMU Munich, Germany
| | - Claus Belka
- Department of Radiation Oncology, University Hospital, LMU Munich, Germany; German Cancer Consortium (DKTK), Munich, Germany
| | - Stefanie Corradini
- Department of Radiation Oncology, University Hospital, LMU Munich, Germany
| |
Collapse
|
10
|
Murakami N, Ohno T, Toita T, Ando K, Ii N, Okamoto H, Kojima T, Tsujino K, Masui K, Yoshida K, Ikushima H. Japanese Society for Radiation Oncology Consensus Guidelines of combined intracavitary and interstitial brachytherapy for gynecological cancers. JOURNAL OF RADIATION RESEARCH 2022; 63:402-411. [PMID: 35349700 PMCID: PMC9124614 DOI: 10.1093/jrr/rrac011] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/12/2021] [Revised: 01/25/2022] [Indexed: 05/31/2023]
Abstract
It has been postulated that the combination of intracavitary and interstitial brachytherapy (IC/IS) is effective and safe for large and irregularly shaped uterine cervical cancer patients. However, due to its invasiveness compared to conventional intracavitary brachytherapy (ICBT), it has to be said that the implementation speed of IC/IS is slow. Until now, there have been no guidelines for required equipment, human resources, and procedural guide focusing solely on IC/IS. The purpose of this guideline is to provide radiation oncologists and medical physicists who wish to start IC/IS with practical and comprehensive guidance for a safe IC/IS introduction and to help accelerate the spread of the utilization of IC/IS nationwide. This is the English translation of the Japanese IC/IS Guidelines, and it was created in an effort to share the Japanese approach to the management of locally advanced uterine cervical cancer worldwide.
Collapse
Affiliation(s)
- Naoya Murakami
- Department of Radiation Oncology, National Cancer Center Hospital, Tokyo 104-0045, Japan
| | - Tatsuya Ohno
- Corresponding author. Department of Radiation Oncology, Gunma University Graduate School of Medicine, Gunma 371-8511, Japan.
| | - Takafumi Toita
- Radiation Therapy Center, Okinawa Chubu Hospital, Okinawa 904-2293, Japan
| | - Ken Ando
- Department of Radiation Oncology, Gunma University Graduate School of Medicine, Gunma 371-8511, Japan
| | - Noriko Ii
- Department of Radiation Oncology, Ise Red Cross Hospital, Mie 516-8512, Japan
| | - Hiroyuki Okamoto
- Radiation Safety and Quality Assurance Division, National Cancer Center Hospital, Tokyo 104-0045, Japan
| | - Toru Kojima
- Department of Radiation Oncology, Saitama Cancer Center, Saitama 362-0806, Japan
| | - Kayoko Tsujino
- Department of Radiation Oncology, Hyogo Cancer Center, Hyogo 673-8558, Japan
| | - Koji Masui
- Department of Radiology, Kyoto Prefectural University of Medicine, Kyoto 602-8566, Japan
| | - Ken Yoshida
- Department of Radiology, Kansai Medical University Medical Center, Osaka 573-1191, Japan
| | - Hitoshi Ikushima
- Institute of Biomedical Sciences, Tokushima University Graduate School, Tokushima 770-8503, Japan
| |
Collapse
|
11
|
Chi Y, Pan Y, Zhang N, Han D, Guo X, Mao Z, Cheng G. Clinical Outcomes of MRI-Guided Adaptive Brachytherapy for Each Fraction in Locally Advanced Cervical Cancer: A Single Institution Experience. Front Oncol 2022; 12:841980. [PMID: 35372065 PMCID: PMC8968417 DOI: 10.3389/fonc.2022.841980] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2021] [Accepted: 02/17/2022] [Indexed: 11/13/2022] Open
Abstract
Purpose This study aims to evaluate clinical outcomes of MRI-guided adaptive brachytherapy (MR-IGABT) for each brachytherapy fraction in patients with locally advanced cervical cancer (LACC). Methods and Materials A retrospective analysis was performed on 97 consecutive patients with LACC treated with 44.0–50.4 Gy external beam radiotherapy (EBRT) ± concurrent platinum-containing chemotherapy followed by 4 × 7 Gy MR-IGABT between September 2014 and April 2019. Intracavitary (IC)/interstitial (IS)/hybrid intracavitary and interstitial (IC/IS) brachytherapy was used in MR-IGABT. Brachytherapy planning and dose reporting followed the GEC-ESTRO recommendations. Clinical outcomes including overall survival (OS), cancer-specific survival (CSS), progression-free survival (PFS), local control (LC), and treatment-related toxicity evaluated by the RTOG criteria were analyzed. Kaplan–Meier and univariable and multivariable Cox regression analyses were used to analyze the prognostic factor. Results Median follow-up was 21.1 months. Median dose to 90% (D90) of the high-risk clinical target volume (HR-CTV) was 91.7 Gy (range 76.7~107.2 Gy). Two-year OS, CSS, PFS, and LC were 83.5%, 84.1%, 71.1%, and 94.8%, respectively. Four patients (4.1%) suffered from grade 3 late gastrointestinal radiation toxicity, and no other grade 3 or greater radiation toxicity occurred. Initial HR-CTV was an independent factor of OS (p = 0.001, HR = 1.018/cm3), PFS (p = 0.012, HR = 1.012/cm3), and LC (p = 0.011, HR = 1.028/cm3). The HR-CTV D90 (p = 0.044, HR = 0.923/Gy) was an independent factor of PFS. Age was an independent factor of LC (p = 0.010, HR = 1.111/year). Conclusion For patients with LACC, MR-IGABT was effective and safe. It showed favorable LC, OS, and minimal toxicity. Moreover, initial HR-CTV, HR-CTV D90, and age were significant prognostic factors.
Collapse
Affiliation(s)
- Yunbo Chi
- Department of Radiation Oncology, China-Japan Union Hospital of Jilin University, Changchun, China
| | - Ying Pan
- Department of Gynecology, China-Japan Union Hospital of Jilin University, Changchun, China
| | - Ning Zhang
- Department of Radiation Oncology, China-Japan Union Hospital of Jilin University, Changchun, China
| | - Dongmei Han
- Department of Radiation Oncology, China-Japan Union Hospital of Jilin University, Changchun, China
| | - Xin Guo
- Department of Radiation Oncology, China-Japan Union Hospital of Jilin University, Changchun, China
| | - Zhuang Mao
- Department of Radiation Oncology, China-Japan Union Hospital of Jilin University, Changchun, China
| | - Guanghui Cheng
- Department of Radiation Oncology, China-Japan Union Hospital of Jilin University, Changchun, China
- *Correspondence: Guanghui Cheng,
| |
Collapse
|
12
|
Sturdza AE, Knoth J. Image-guided brachytherapy in cervical cancer including fractionation. Int J Gynecol Cancer 2022; 32:273-280. [DOI: 10.1136/ijgc-2021-003056] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Accepted: 12/14/2021] [Indexed: 02/02/2023] Open
Abstract
Image-guided brachytherapy in cervical cancer has been developed to be a feasible and very efficient component of the treatment of locally advanced cervical cancer in addition to concurrent chemoradiation treatment. This technique allows effective dose coverage of the target while sparing the organs at risk through adjustment of the implants (intracavitary and interstitial needles) and multi-pararametric three-dimensional treatment planning. Emerging evidence from prospective studies shows a high rate of local control throughout all stages, superior to two-dimensional brachytherapy, with limited toxicity for each organ site. This is associated with a high rate of pelvic control and overall survival. Based on clinical evidence, there is a dose–effect relationship for both disease and morbidity endpoints from which clear dose constraints for the target and organs at risk were derived. This review gives an overview of the major milestones that occurred in the development of image-guided adaptive brachytherapy in the last two decades, including outcome data and a summary of the hard and soft dose constraints recommended for targets and organs at risk.
Collapse
|
13
|
Musunuru HB, Pifer PM, Mohindra P, Albuquerque K, Beriwal S. Advances in management of locally advanced cervical cancer. Indian J Med Res 2021; 154:248-261. [PMID: 35142642 PMCID: PMC9131769 DOI: 10.4103/ijmr.ijmr_1047_20] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Globally, cervical cancer has the fourth highest cancer incidence and mortality in women. Cervical cancer is unique because it has effective prevention, screening, and treatment options. This review discusses the current cervical cancer advances with a focus on locally advanced cervical cancer. Topics discussed include diagnostic imaging principles, surgical management with adjuvant therapy and definitive concurrent chemoradiotherapy. Emphasis is given on current advances and future research directions in radiation therapy (RT) with an emphasis on three-dimensional brachytherapy, intensity-modulated RT, image-guided RT, proton RT and hyperthermia.
Collapse
Affiliation(s)
- Hima Bindu Musunuru
- Department of Radiation Oncology, University of Pittsburgh Medical Center Hillman Cancer Center, Pittsburgh, Pennsylvania, USA
| | - Phillip M Pifer
- Department of Radiation Oncology, University of Pittsburgh Medical Center Hillman Cancer Center, Pittsburgh, Pennsylvania, USA
| | - Pranshu Mohindra
- Department of Radiation Oncology, University of Maryland School of Medicine, Maryland Proton Treatment Center, Baltimore, Maryland, USA
| | - Kevin Albuquerque
- Department of Radiation Oncology, Harold C. Simmons Comprehensive Cancer Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Sushil Beriwal
- Department of Radiation Oncology, University of Pittsburgh Medical Center Hillman Cancer Center, Pittsburgh, Pennsylvania, USA
| |
Collapse
|
14
|
Rivera A, Wassel M, Brodin PN, Yaparpalvi R, Velten C, Kabarriti R, Garg M, Kalnicki S, Mehta KJ. Hybrid tandem and ovoids brachytherapy in locally advanced cervical cancer: impact of dose and tumor volume metrics on outcomes. J Contemp Brachytherapy 2021; 13:158-166. [PMID: 33897789 PMCID: PMC8060962 DOI: 10.5114/jcb.2021.105283] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2020] [Accepted: 02/21/2021] [Indexed: 11/17/2022] Open
Abstract
PURPOSE To report the impact of dose and tumor volume metrics at brachytherapy on outcomes for locally advanced cervical cancer treated with tandem and ovoids intracavitary/interstitial brachytherapy. MATERIAL AND METHODS FIGO stage IB1-IIIB locally advanced cervical cancer treated with intracavitary/interstitial brachytherapy via a tandem and ovoids hybrid applicator were analyzed. Median high-risk clinical target volume (HR-CTV), rate of tumor volume reduction, EQD2 D90, organ at risk doses, and outcomes were recorded. Univariable and multivariable Cox regression was applied for survival analysis, and logistic regression was used for toxicity analysis. RESULTS Seventy-one patients were identified. Median follow-up was 24.9 months, with a 2-year local control of 83.6%, loco-regional control of 72.0%, and overall survival of 88.6%. Median HR-CTV D90 was 87.4 Gy (IQR = 85.7-90.2). Median HR-CTV D90 > 90 Gy10 showed a trend toward improved local control (LC) (p = 0.19). Median HR-CTV was 37.9 cm3, and median V100 was 86.5%. A median HR-CTV of ≥ 40 cm3 demonstrated worse loco-regional control (LRC) (p = 0.018) and progression-free survival (p = 0.021). Two-year LC and LRC for stage IIB patients with a median HR-CTV < 40 cm3 were significantly improved as compared to ≥ 40 cm3 at 100% and 71.8%, respectively (p = 0.019) and 100% and 56.5%, respectively (p = 0.001). However, this trend was not statistically significant for stage IIIB patients. Higher percent per day reduction in HR-CTV during brachytherapy showed improved LRC (p = 0.045). Four percent of patients experienced acute grade 3 genitourinary toxicity, 1% late grade 3 genitourinary and 1% late grade 3 gastrointestinal toxicity. CONCLUSIONS Tandem and ovoids intracavitary/interstitial brachytherapy provides satisfactory outcomes with modest toxicity. Higher HR-CTV D90 coverage demonstrated a trend toward improved tumor control. Tumor volume based on median HR-CTV ≥ 40 cm3 at brachytherapy was prognostic for poor outcomes, even within initial FIGO stage groups warranting caution.
Collapse
Affiliation(s)
- Amanda Rivera
- Department of Radiation Oncology, Montefiore Medical Center/Albert Einstein College of Medicine, New York, USA
| | | | - Patrik N. Brodin
- Department of Radiation Oncology, Montefiore Medical Center/Albert Einstein College of Medicine, New York, USA
- Albert Einstein College of Medicine, New York, USA
| | - Ravindra Yaparpalvi
- Department of Radiation Oncology, Montefiore Medical Center/Albert Einstein College of Medicine, New York, USA
| | - Christian Velten
- Department of Radiation Oncology, Montefiore Medical Center/Albert Einstein College of Medicine, New York, USA
| | - Rafi Kabarriti
- Department of Radiation Oncology, Montefiore Medical Center/Albert Einstein College of Medicine, New York, USA
| | - Madhur Garg
- Department of Radiation Oncology, Montefiore Medical Center/Albert Einstein College of Medicine, New York, USA
| | - Shalom Kalnicki
- Department of Radiation Oncology, Montefiore Medical Center/Albert Einstein College of Medicine, New York, USA
| | - Keyur J. Mehta
- Department of Radiation Oncology, Montefiore Medical Center/Albert Einstein College of Medicine, New York, USA
| |
Collapse
|