1
|
Campanella S, Paragliola G, Cherubini V, Pierleoni P, Palma L. Towards Personalized AI-Based Diabetes Therapy: A Review. IEEE J Biomed Health Inform 2024; 28:6944-6957. [PMID: 39137085 DOI: 10.1109/jbhi.2024.3443137] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/15/2024]
Abstract
Insulin pumps and other smart devices have recently made significant advancements in the treatment of diabetes, a disorder that affects people all over the world. The development of medical AI has been influenced by AI methods designed to help physicians make diagnoses, choose a course of therapy, and predict outcomes. In this article, we thoroughly analyse how AI is being used to enhance and personalize diabetes treatment. The search turned up 77 original research papers, from which we've selected the most crucial information regarding the learning models employed, the data typology, the deployment stage, and the application domains. We identified two key trends, enabled mostly by AI: patient-based therapy personalization and therapeutic algorithm optimization. In the meanwhile, we point out various shortcomings in the existing literature, like a lack of multimodal database analysis or a lack of interpretability. The rapid improvements in AI and the expansion of the amount of data already available offer the possibility to overcome these difficulties shortly and enable a wider deployment of this technology in clinical settings.
Collapse
|
2
|
Sanz R, García P, Romero-Vivó S, Díez JL, Bondia J. Near-optimal feedback control for postprandial glucose regulation in type 1 diabetes. ISA TRANSACTIONS 2023; 133:345-352. [PMID: 36116963 DOI: 10.1016/j.isatra.2022.06.033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Revised: 04/19/2022] [Accepted: 06/26/2022] [Indexed: 06/15/2023]
Abstract
This paper is focused on feedback control of postprandial glucose levels for patients with type 1 Diabetes Mellitus. There are two important limitations that make this a challenging problem. First, the slow subcutaneous insulin pharmacokinetics that introduces a significant lag into the control loop. Second, the positivity constraint on the control action, meaning that it is not possible to remove insulin from the body. In this paper, both issues are explicitly considered in the design process using the internal model control framework, to derive a near-optimal feedback controller. Optimality is understood here as minimizing the blood glucose peak after a meal intake and, at the same time, preventing glucose values below a prescribed threshold. It is shown how the proposed controller approaches the optimal closed-loop performance as a limit case. The theoretical results are supported by a numerical example and the feasibility of the overall strategy under uncertainties is illustrated using an extended version UVa/Padova metabolic simulator.
Collapse
Affiliation(s)
- R Sanz
- Instituto de Automática e Informática Industrial, Universitat Politècnica de València, 46022 València, Spain.
| | - P García
- Instituto de Automática e Informática Industrial, Universitat Politècnica de València, 46022 València, Spain.
| | - S Romero-Vivó
- Instituto de Matemática Multidisciplinar, Universitat Politècnica de València, 46022 València, Spain; Centro de Investigación Biomédica en Red de Diabetes y Enfermedades Metabólicas Asociadas, Instituto de Salud Carlos III, 28029 Madrid, Spain.
| | - J L Díez
- Instituto de Automática e Informática Industrial, Universitat Politècnica de València, 46022 València, Spain; Centro de Investigación Biomédica en Red de Diabetes y Enfermedades Metabólicas Asociadas, Instituto de Salud Carlos III, 28029 Madrid, Spain.
| | - J Bondia
- Instituto de Automática e Informática Industrial, Universitat Politècnica de València, 46022 València, Spain; Centro de Investigación Biomédica en Red de Diabetes y Enfermedades Metabólicas Asociadas, Instituto de Salud Carlos III, 28029 Madrid, Spain.
| |
Collapse
|
3
|
Sala-Mira I, Garcia P, Díez JL, Bondia J. Internal model control based module for the elimination of meal and exercise announcements in hybrid artificial pancreas systems. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2022; 226:107061. [PMID: 36116400 DOI: 10.1016/j.cmpb.2022.107061] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/11/2022] [Revised: 07/15/2022] [Accepted: 08/07/2022] [Indexed: 06/15/2023]
Abstract
BACKGROUND AND OBJECTIVES Hybrid artificial pancreas systems outperform current insulin pump therapies in blood glucose regulation in type 1 diabetes. However, subjects still have to inform the system about meals intake and exercise to achieve reasonable control. These patient announcements may result in overburden and compromise controller performance if not provided timely and accurately. Here, a hybrid artificial pancreas is extended with an add-on module that releases subjects from meals and exercise announcements. METHODS The add-on module consists of an internal-model controller that generates a "virtual" control action to compensate for disturbances. This "virtual" action is converted into insulin delivery, rescue carbohydrates suggestions, or insulin-on-board limitations, depending on a switching logic based on glucose measurements and predictions. The controller parameters are tuned by optimization and then related to standard parameters from the open-loop therapy. This module is implemented in a hybrid artificial pancreas system proposed by our research group for validation. This hybrid system extended with the add-on module is compared with the hybrid controller with carbohydrate counting errors (hybrid) and the hybrid controller with an alternative unannounced meal compensation module based on a meal detection algorithm (meal detector). The validation used the educational version of the UVa/Padova simulator to simulate the three controllers under two scenarios: one with only meals and another with meals and exercise. The exercise was modeled as a temporal increase of the insulin sensitivity resulting in the glucose drop usually related to an aerobic exercise. RESULTS For the scenario with only meals, the three controllers achieved similar time in range (proposed: 85.1 [77.9,88.1]%, hybrid: 84.0 [75.9,86.4]%, meal detector: 81.9 [79.3,83.8]%, median [interquartile range]) with low time in moderate hypoglycemia. Under the scenario with meals and exercise, the proposed module reduces 4.61% the time in hypoglycemia achieved with the other controllers, suggesting an acceptable amount of rescues (27.2 [23.7, 31.0] g). CONCLUSIONS The proposed add-on module achieved promising results: it outperformed the meal-detector-based controller, even achieving a postprandial performance as good as the hybrid controller (with carbohydrate counting errors). Also, the rescue suggestion feature of the module mitigated exercise-induced hypoglycemia with admissible rescue amounts.
Collapse
Affiliation(s)
- Iván Sala-Mira
- Instituto Universitario de Automática e Informática Industrial, Universitat Politécnica de Valéncia, Valencia 46022, Spain
| | - Pedro Garcia
- Instituto Universitario de Automática e Informática Industrial, Universitat Politécnica de Valéncia, Valencia 46022, Spain
| | - José-Luis Díez
- Instituto Universitario de Automática e Informática Industrial, Universitat Politécnica de Valéncia, Valencia 46022, Spain; Centro de Investigación Biomédica en Red de Diabetes y Enfermedades Metabólicas Asociadas, Instituto de Salud Carlos III, Spain
| | - Jorge Bondia
- Instituto Universitario de Automática e Informática Industrial, Universitat Politécnica de Valéncia, Valencia 46022, Spain; Centro de Investigación Biomédica en Red de Diabetes y Enfermedades Metabólicas Asociadas, Instituto de Salud Carlos III, Spain.
| |
Collapse
|
4
|
Faccioli S, Sala-Mira I, Díez JL, Facchinetti A, Sparacino G, Del Favero S, Bondia J. Super-twisting-based meal detector for type 1 diabetes management: Improvement and assessment in a real-life scenario. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2022; 219:106736. [PMID: 35338888 DOI: 10.1016/j.cmpb.2022.106736] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2021] [Revised: 02/24/2022] [Accepted: 03/06/2022] [Indexed: 06/14/2023]
Abstract
BACKGROUND AND OBJECTIVE Hybrid automated insulin delivery systems rely on carbohydrate counting to improve postprandial control in type 1 diabetes. However, this is an extra burden on subjects, and it introduces a source of potential errors that could impact control performances. In fact, carbohydrates estimation is challenging, prone to errors, and it is known that subjects sometimes struggle to adhere to this requirement, forgetting to perform this task. A possible solution is the use of automated meal detection algorithms. In this work, we extended a super-twisting-based meal detector suggested in the literature and assessed it on real-life data. METHODS To reduce the false detections in the original meal detector, we implemented an implicit discretization of the super-twisting and replaced the Euler approximation of the glucose derivative with a Kalman filter. The modified meal detector is retrospectively evaluated in a challenging real-life dataset corresponding to a 2-week trial with 30 subjects using sensor-augmented pump control. The assessment includes an analysis of the nature and riskiness of false detections. RESULTS The proposed algorithm achieved a recall of 70 [13] % (median [interquartile range]), a precision of 73 [26] %, and had 1.4 [1.4] false positives-per-day. False positives were related to rising glucose conditions, whereas false negatives occurred after calibrations, missing samples, or hypoglycemia treatments. CONCLUSIONS The proposed algorithm achieves encouraging performance. Although false positives and false negatives were not avoided, they are related to situations with a low risk of hypoglycemia and hyperglycemia, respectively.
Collapse
Affiliation(s)
- S Faccioli
- Department of Information Engineering - DEI, University of Padova, 35131, PD, Italy
| | - I Sala-Mira
- Instituto Universitario de Automática e Informática Industrial, Universitat Politècnica de València, Valencia, 46022, Spain
| | - J L Díez
- Instituto Universitario de Automática e Informática Industrial, Universitat Politècnica de València, Valencia, 46022, Spain; Centro de Investigación Biomédica en Red de Diabetes y Enfermedades Metabólicas Asociadas - CIBERDEM, Madrid, 28028, Spain
| | - A Facchinetti
- Department of Information Engineering - DEI, University of Padova, 35131, PD, Italy
| | - G Sparacino
- Department of Information Engineering - DEI, University of Padova, 35131, PD, Italy
| | - S Del Favero
- Department of Information Engineering - DEI, University of Padova, 35131, PD, Italy.
| | - J Bondia
- Instituto Universitario de Automática e Informática Industrial, Universitat Politècnica de València, Valencia, 46022, Spain; Centro de Investigación Biomédica en Red de Diabetes y Enfermedades Metabólicas Asociadas - CIBERDEM, Madrid, 28028, Spain
| |
Collapse
|
5
|
Abstract
BACKGROUND Artificial pancreas (AP) systems reduce the treatment burden of Type 1 Diabetes by automatically regulating blood glucose (BG) levels. While many disturbances stand in the way of fully closed-loop (automated) control, unannounced meals remain the greatest challenge. Furthermore, different types of meals can have significantly different glucose responses, further increasing the uncertainty surrounding the meal. METHODS Effective attenuation of a meal requires quick and accurate insulin delivery because of slow insulin action relative to meal effects on BG. The proposed Variable Hump (VH) model adapts to meals of varying compositions by inferring both meal size and shape. To appropriately address the uncertainty of meal size, the model divides meal absorption into two disjoint regions: a region with coarse meal size predictions followed by a fine-grain region where predictions are fine-tuned by adapting to the meal shape. RESULTS Using gold-standard triple tracer meal data, the proposed VH model is compared to three simpler second-order response models. The proposed VH model increased model fit capacity by 22% and prediction accuracy by 12% relative to the next best models. A 47% increase in the accuracy of uncertainty predictions was also found. In a simple control scenario, the controller governed by the proposed VH model provided insulin just as fast or faster than the controller governed by the other models in four out of the six meals. While the controllers governed by the other models all delivered at least a 25% excess of insulin at their worst, the VH model controller only delivered 9% excess at its worst. CONCLUSIONS The VH Model performed best in accuracy metrics and succeeded over the other models in providing insulin quickly and accurately in a simple implementation. Use in an AP system may improve prediction accuracy and lead to better control around mealtimes.
Collapse
Affiliation(s)
- Travis Diamond
- Department of Chemical and Biological Engineering, Rensselaer Polytechnic Institute, Troy, NY, USA
| | - Faye Cameron
- Department of Chemical and Biological Engineering, Rensselaer Polytechnic Institute, Troy, NY, USA
| | - B. Wayne Bequette
- Department of Chemical and Biological Engineering, Rensselaer Polytechnic Institute, Troy, NY, USA
- B. Wayne Bequette, PhD, Rensselaer Polytechnic Institute, 110 8th St, Troy, NY 12180, USA.
| |
Collapse
|
6
|
Beneyto A, Bequette BW, Vehi J. Fault Tolerant Strategies for Automated Insulin Delivery Considering the Human Component: Current and Future Perspectives. J Diabetes Sci Technol 2021; 15:1224-1231. [PMID: 34286613 PMCID: PMC8655284 DOI: 10.1177/19322968211029297] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Automated Insulin Delivery (AID) are systems developed for daily use by people with type 1 diabetes (T1D). To ensure the safety of users, it is essential to consider how the human factor affects the performance and safety of these devices. While there are numerous publications on hardware-related failures of AID systems, there are few studies on the human component of the system. From a control point of view, people with T1D using AID systems are at the same time the plant to be controlled and the plant operator. Therefore, users may induce faults in the controller, sensors, actuators, and the plant itself. Strategies to cope with the human interaction in AID systems are needed for further development of the technology. In this paper, we present an analysis of potential faults introduced by AID users when the system is under normal operation. This is followed by a review of current fault tolerant control (FTC) approaches to identify missing areas of research. The paper concludes with a discussion on future directions for the new generation of FTC AID systems.
Collapse
Affiliation(s)
| | | | - Josep Vehi
- Universitat de Girona, Girona, Spain
- Centro de Investigación Biomédica en Red de Diabetes y Enfermedades Metabólicas Asociadas, Madrid, Spain
| |
Collapse
|
7
|
Meal detection and carbohydrate estimation based on a feedback scheme with application to the artificial pancreas. Biomed Signal Process Control 2021. [DOI: 10.1016/j.bspc.2021.102715] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
8
|
Application of Systems Engineering Principles and Techniques in Biological Big Data Analytics: A Review. Processes (Basel) 2020. [DOI: 10.3390/pr8080951] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
In the past few decades, we have witnessed tremendous advancements in biology, life sciences and healthcare. These advancements are due in no small part to the big data made available by various high-throughput technologies, the ever-advancing computing power, and the algorithmic advancements in machine learning. Specifically, big data analytics such as statistical and machine learning has become an essential tool in these rapidly developing fields. As a result, the subject has drawn increased attention and many review papers have been published in just the past few years on the subject. Different from all existing reviews, this work focuses on the application of systems, engineering principles and techniques in addressing some of the common challenges in big data analytics for biological, biomedical and healthcare applications. Specifically, this review focuses on the following three key areas in biological big data analytics where systems engineering principles and techniques have been playing important roles: the principle of parsimony in addressing overfitting, the dynamic analysis of biological data, and the role of domain knowledge in biological data analytics.
Collapse
|
9
|
Villeneuve E, Lachal S, Desir C, Benhamou PY, Franc S, Charpentier G, Huneker E, Doron M. Increasing the safety of unannounced meal detection for artificial pancreas closed-loop with patient's hourly meal schedule. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2020:5093-5096. [PMID: 33019132 DOI: 10.1109/embc44109.2020.9176470] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
The daily challenge for people with type 1 diabetes is maintaining glycaemia in the "normal" range after meals, by injecting themselves the correct amount of insulin. Artificial pancreas systems were developed to adjust insulin delivery based on real-time monitoring of glycaemia and meal patient's report. Meal reporting is a heavy burden for patients as it requires carbohydrate estimation several times per day. To improve patient's quality of life and treatment, several methods aim at detecting unannounced meals. While untreated meals lead to hyperglycaemia and in the long-term to comorbidities, treating falsely detected meals can cause hypoglycaemia and coma. In this paper, we propose to customise the meal detection to the patient's hourly meal probability in order to limit false detection of unannounced meals.
Collapse
|
10
|
Tyler NS, Jacobs PG. Artificial Intelligence in Decision Support Systems for Type 1 Diabetes. SENSORS (BASEL, SWITZERLAND) 2020; 20:E3214. [PMID: 32517068 PMCID: PMC7308977 DOI: 10.3390/s20113214] [Citation(s) in RCA: 41] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/01/2020] [Revised: 05/29/2020] [Accepted: 06/02/2020] [Indexed: 12/16/2022]
Abstract
Type 1 diabetes (T1D) is a chronic health condition resulting from pancreatic beta cell dysfunction and insulin depletion. While automated insulin delivery systems are now available, many people choose to manage insulin delivery manually through insulin pumps or through multiple daily injections. Frequent insulin titrations are needed to adequately manage glucose, however, provider adjustments are typically made every several months. Recent automated decision support systems incorporate artificial intelligence algorithms to deliver personalized recommendations regarding insulin doses and daily behaviors. This paper presents a comprehensive review of computational and artificial intelligence-based decision support systems to manage T1D. Articles were obtained from PubMed, IEEE Xplore, and ScienceDirect databases. No time period restrictions were imposed on the search. After removing off-topic articles and duplicates, 562 articles were left to review. Of those articles, we identified 61 articles for comprehensive review based on algorithm evaluation using real-world human data, in silico trials, or clinical studies. We grouped decision support systems into general categories of (1) those which recommend adjustments to insulin and (2) those which predict and help avoid hypoglycemia. We review the artificial intelligence methods used for each type of decision support system, and discuss the performance and potential applications of these systems.
Collapse
Affiliation(s)
| | - Peter G. Jacobs
- Artificial Intelligence for Medical Systems Lab, Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR 97239, USA;
| |