Le Fèvre C, Buffard E, Antoni D, Chaussemy D, Matter-Parrat V, Noël G. [Consequences of prosthesis on quality of the radiation therapy]. Cancer Radiother 2016; 20 Suppl:S259-63. [PMID: 27522190 DOI: 10.1016/j.canrad.2016.07.023] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
Dose prescription, delineation and dose calculation are clearly complicated when a patient have been operated on with insertion of prosthesis. Knowledge of the physical and material characteristics is needed to decrease incertitude of calculations. Recommendations for each step of treatments are proposed in this article allowing to optimization of the treatment safety.
Collapse
Affiliation(s)
- C Le Fèvre
- Département universitaire de radiothérapie, centre Paul-Strauss, Unicancer, 3, rue de la Porte-de-l'Hôpital, 67065 Strasbourg cedex, France
| | - E Buffard
- Service de radiothérapie, hôpitaux civils de Colmar, 39, avenue de la Liberté, 68024 Colmar cedex, France
| | - D Antoni
- Département universitaire de radiothérapie, centre Paul-Strauss, Unicancer, 3, rue de la Porte-de-l'Hôpital, 67065 Strasbourg cedex, France
| | - D Chaussemy
- Service de neurochirurgie, CHU de Strasbourg, hôpital de Hautepierre, 1, avenue Molière, 67098 Strasbourg cedex, France
| | - V Matter-Parrat
- Service d'orthopédie, hôpital civil, CHU de Strasbourg, 1, place de l'Hôpital, 67000 Strasbourg, France
| | - G Noël
- Département universitaire de radiothérapie, centre Paul-Strauss, Unicancer, 3, rue de la Porte-de-l'Hôpital, 67065 Strasbourg cedex, France; Laboratoire EA 3430, Fédération de médecine translationnelle de Strasbourg, université de Strasbourg, 67000 Strasbourg, France.
| |
Collapse
|
2
|
[From image-guided radiotherapy to dose-guided radiotherapy]. Cancer Radiother 2011; 15:691-8. [PMID: 22094020 DOI: 10.1016/j.canrad.2011.05.011] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2010] [Revised: 04/21/2011] [Accepted: 05/21/2011] [Indexed: 11/22/2022]
Abstract
PURPOSE In case of tumour displacement, image-guided radiotherapy (IGRT) based on the use of cone beam CT (tomographie conique) allows replacing the tumour under the accelerator by rigid registration. Anatomical deformations require however replanning, involving an estimation of the cumulative dose, session after session. This is the objective of this study. PATIENTS AND METHODS Two examples of arc-intensity modulated radiotherapy are presented: a case of prostate cancer (total dose=80 Gy) with tomographie conique (daily prostate registration) and one head and neck cancer (70 Gy). For the head and neck cancer, the patient had a weekly scanner allowing a dose distribution calculation. The cumulative dose was calculated per voxel on the planning CT after deformation of the dose distribution (with trilinear interpolation) following the transformation given by a non-rigid registration step (Demons registration method) from: either the tomographie conique (prostate), or the weekly CT. The cumulative dose was eventually compared with the planned dose. RESULTS In cases of prostate irradiation, the "cumulative" dose corresponded to the planned dose to the prostate. At the last week of irradiation, it was above the planned dose for the rectum and bladder. The volume of rectal wall receiving more than 50 Gy (V50) was 20% at the planning and 26% at the end of treatment, increasing the risk of rectal toxicity (NTCP) of 14%. For the bladder wall, V50 were 73% and 82%, respectively. In head and neck, the "cumulative" dose to the parotid exceeded the planned dose (mean dose increasing from 46 Gy to 54 Gy) from the 5th week of irradiation on, suggesting the need for replanning within the first 5 weeks of radiotherapy. CONCLUSION The deformable registration estimates the cumulative dose delivered in the different anatomical structures. Validation on digital and physical phantoms is however required before clinical evaluation.
Collapse
|
3
|
Dewas S, Bibault JE, Blanchard P, Vautravers-Dewas C, Pointreau Y, Denis F, Brauner M, Giraud P. Delineation in thoracic oncology: a prospective study of the effect of training on contour variability and dosimetric consequences. Radiat Oncol 2011; 6:118. [PMID: 21929770 PMCID: PMC3195101 DOI: 10.1186/1748-717x-6-118] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2011] [Accepted: 09/19/2011] [Indexed: 12/17/2022] Open
Abstract
Introduction As part of French residents' radiotherapy training, delineation workstations were available at a national teaching course. We report a prospective comparative study of a non small cell lung cancer (NSCLC) case delineated by 120 residents before and after a radioanatomy/radiotherapy lecture. Materials and methods The case of a patient with right upper lobe non small cell lung cancer (NSCLC) was provided for delineation to 32 groups of residents before and after a radiation therapy lecture about thoracic delineation. GTV, CTV and PTV was asked to each group. In a second step, the GTV, CTV and PTV were compared with those of 9 groups of senior physicians. Finally the consequences for treatment planning between each group before and after the course were explored. Results The expert's average GTV, CTV and PTV were 89.1 cm3, 242.3 cm3 and 293.9 cm3 respectively. For residents, those volumes were 103.4 cm3, 242.3 cm3 and 457.9 cm3 before teaching, compared to 99.5 cm3, 224.2 cm3 and 412.5 cm3 after teaching. The overlap (OV) and kappa (KI) indices before and after education were respectively 0.58 and 0.73. Compared to senior physicians, OV and KI indices were lower in the residents group (p = 0.039 and p = 0.043). An increased dose to the lung is noted for the residents' dosimetry compared to the experts' (V20: 23.2% versus 36.5%) due to the larger PTV delineated. No significant difference was observed for other organs at risk. Conclusion There were no significant differences for the delineation of the GTV and CTV before and after the course, although the differences tended to decrease after the course. The good initial quality of the contours could explain the lack of difference. V20 for lung was higher in the residents group compared to the experts group (23.2% vs 36.5%). No other treatment planning consequences were observed for other critical organs.
Collapse
Affiliation(s)
- Sylvain Dewas
- Département universitaire de Radiothérapie, Centre Oscar Lambret, Université Lille II, Lille, France.
| | | | | | | | | | | | | | | |
Collapse
|
4
|
Variabilité inter-radiothérapeutes de la délinéation tumorale en oncologie thoracique : exemples d’intercomparaison de délinéations et impact de la formation. Cancer Radiother 2010; 14:103-10. [DOI: 10.1016/j.canrad.2009.11.002] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2009] [Revised: 10/20/2009] [Accepted: 11/14/2009] [Indexed: 11/23/2022]
|
5
|
Fuller CD, Scarbrough TJ, Sonke JJ, Rasch CRN, Choi M, Ting JY, Wang SJ, Papanikolaou N, Rosenthal DI. Method comparison of automated matching software-assisted cone-beam CT and stereoscopic kilovoltage x-ray positional verification image-guided radiation therapy for head and neck cancer: a prospective analysis. Phys Med Biol 2009; 54:7401-15. [PMID: 19934488 PMCID: PMC5343752 DOI: 10.1088/0031-9155/54/24/010] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
We sought to characterize interchangeability and agreement between cone-beam computed tomography (CBCT) and digital stereoscopic kV x-ray (KVX) acquisition, two methods of isocenter positional verification currently used for IGRT of head and neck cancers (HNC). A cohort of 33 patients were near-simultaneously imaged by in-room KVX and CBCT. KVX and CBCT shifts were suggested using manufacturer software for the lateral (X), vertical (Y) and longitudinal (Z) dimensions. Intra-method repeatability, systematic and random error components were calculated for each imaging modality, as were recipe-based PTV expansion margins. Inter-method agreement in each axis was compared using limits of agreement (LOA) methodology, concordance analysis and orthogonal regression. 100 daily positional assessments were performed before daily therapy in 33 patients with head and neck cancer. Systematic error was greater for CBCT in all axes, with larger random error components in the Y- and Z-axis. Repeatability ranged from 9 to 14 mm for all axes, with CBCT showing greater repeatability in 2/3 axes. LOA showed paired shifts to agree 95% of the time within +/-11.3 mm in the X-axis, +/-9.4 mm in the Y-axis and +/-5.5 mm in the Z-axis. Concordance ranged from 'mediocre' to 'satisfactory'. Proportional bias was noted between paired X- and Z-axis measures, with a constant bias component in the Z-axis. Our data suggest non-negligible differences in software-derived CBCT and KVX image-guided directional shifts using formal method comparison statistics.
Collapse
Affiliation(s)
- Clifton D Fuller
- Department of Radiation Oncology, University of Texas Health Science Center-San Antonio, San Antonio, TX, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
6
|
de Crevoisier R, Garcia R, Louvel G, Marguet M, Lafond C, Bodez V. Radiothérapie guidée par la tomographie conique (cone beam computed tomography) : mise en œuvre et applications cliniques. Cancer Radiother 2009; 13:482-9. [DOI: 10.1016/j.canrad.2009.06.018] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2009] [Revised: 06/24/2009] [Accepted: 06/26/2009] [Indexed: 11/24/2022]
|
7
|
Cazoulat G, de Crevoisier R, Simon A, Louvel G, Manens JP, Lafond C, Haigron P. Bénéfice volumétrique de la radiothérapie guidée par l’image dans les cancers prostatiques : marges et cartographies de probabilité de présence. Cancer Radiother 2009; 13:365-74. [DOI: 10.1016/j.canrad.2009.06.002] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2009] [Revised: 05/27/2009] [Accepted: 06/02/2009] [Indexed: 10/20/2022]
|
8
|
Thomas THM, Devakumar D, Purnima S, Ravindran BP. The adaptation of megavoltage cone beam CT for use in standard radiotherapy treatment planning. Phys Med Biol 2009; 54:2067-77. [PMID: 19287087 DOI: 10.1088/0031-9155/54/7/014] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Potential areas where megavoltage computed tomography (MVCT) could be used are second- and third-phase treatment planning in 3D conformal radiotherapy and IMRT, adaptive radiation therapy, single fraction palliative treatment and for the treatment of patients with metal prostheses. A feasibility study was done on using MV cone beam CT (CBCT) images generated by proprietary 3D reconstruction software based on the FDK algorithm for megavoltage treatment planning. The reconstructed images were converted to a DICOM file set. The pixel values of megavoltage cone beam computed tomography (MV CBCT) were rescaled to those of kV CT for use with a treatment planning system. A calibration phantom was designed and developed for verification of geometric accuracy and CT number calibration. The distance measured between two marker points on the CBCT image and the physical dimension on the phantom were in good agreement. Point dose verification for a 10 cm x 10 cm beam at a gantry angle of 0 degrees and SAD of 100 cm were performed for a 6 MV beam for both kV and MV CBCT images. The point doses were found to vary between +/-6.1% of the dose calculated from the kV CT image. The isodose curves for 6 MV for both kV CT and MV CBCT images were within 2% and 3 mm distance-to-agreement. A plan with three beams was performed on MV CBCT, simulating a treatment plan for cancer of the pituitary. The distribution obtained was compared with those corresponding to that obtained using the kV CT. This study has shown that treatment planning with MV cone beam CT images is feasible.
Collapse
|
9
|
Contrôle qualité d’un système d’imagerie cone beam mégavoltage. Cancer Radiother 2008; 12:781-7. [DOI: 10.1016/j.canrad.2008.06.007] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2008] [Revised: 06/25/2008] [Accepted: 06/29/2008] [Indexed: 11/23/2022]
|
10
|
Rimmer YL, Burnet NG, Routsis DS, Twyman N, Hoole ACF, Treeby J, Welford D, Fairfoul J, 'Aho T, Vowler SL, Benson RJ. Practical issues in the implementation of image-guided radiotherapy for the treatment of prostate cancer within a UK department. Clin Oncol (R Coll Radiol) 2007; 20:22-30. [PMID: 17981443 DOI: 10.1016/j.clon.2007.10.001] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2007] [Revised: 08/20/2007] [Accepted: 10/03/2007] [Indexed: 11/25/2022]
Abstract
AIMS To study the feasibility of using implanted gold seeds in combination with a commercial software system for daily localisation of the prostate gland during conformal radiotherapy, and to assess the effect this may have on departmental workload. MATERIALS AND METHODS Six patients had three gold radio-opaque seeds implanted into the prostate gland before starting a course of radiotherapy. The seeds were identified on daily portal images and an automated online system provided immediate vector analysis of discrepancies between the planned and actual daily position of the intraprostatic seeds. In total, 138 interfractional displacements were analysed. The workload impact for the department was assessed using the basic treatment equivalence model, by comparing measurements of daily treatment session durations with a control group of patients receiving standard conformal radiotherapy, matched for treatment complexity. RESULTS No acute complications of seed insertion were observed. A number of developmental issues required solutions to be identified before clinical implementation was possible. The standard deviations of the set-up and organ motion systematic errors in the left-right, superior-inferior and anterior-posterior directions were 2.4, 3.0 and 2.5 mm, respectively. The standard deviations of the set-up and organ motion random errors calculated were 2.5, 2.9 and 3.7 mm. The mean treatment session duration with this daily prostate localisation system was increased by 3 min compared with matched controls using standard imaging practice. If all radical prostate patients in our department were to receive image-guided radiotherapy in this way, this would increase machine workload time by 2.2 h/day. CONCLUSIONS The implementation of this image-guided system is feasible. No additional linear accelerator modification is required and standard imaging devices can be used. It would be a useful addition to any department's image-guided radiotherapy developmental strategy.
Collapse
Affiliation(s)
- Y L Rimmer
- Oncology Centre, Addenbrooke's Hospital, Cambridge, UK.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
11
|
de Crevoisier R, Isambert A, Lisbona A, Bodez V, Marguet M, Lafay F, Remonnay R, Lagrange JL. Radiothérapie guidée par l'image. Cancer Radiother 2007; 11:296-304. [PMID: 17889585 DOI: 10.1016/j.canrad.2007.08.002] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
Recent advances in radiation oncology are based on improvement in dose distribution thanks to IMRT and improvement in target definition through new diagnostic imaging such as spectroscopic or functional MRI or PET. However, anatomic variations may occur during treatment decreasing the benefit of such optimization. Image-guided radiotherapy reduces geometric uncertainties occurring during treatment and therefore should reduce dose delivered to healthy tissues and enable dose escalation to enhance tumour control. However, IGRT experience is still limited, while a wide panel of IGRT modalities is available. A strong quality control is required for safety and proper evaluation of the clinical benefit of IGRT combined or not with IMRT.
Collapse
Affiliation(s)
- R de Crevoisier
- Département de Radiothérapie, Institut Gustave-Roussy, 39, rue Camille-Desmoulins, 94805, Villejuif, France.
| | | | | | | | | | | | | | | |
Collapse
|
12
|
|
13
|
Delpon G, Warren S, Mahé D, Gaudaire S, Lisbona A. Validation des plans de radiothérapie conformationnelle avec modulation d'intensité avec les images portales. Cancer Radiother 2007; 11:197-205. [PMID: 17392008 DOI: 10.1016/j.canrad.2007.02.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2006] [Revised: 01/12/2007] [Accepted: 02/07/2007] [Indexed: 12/01/2022]
Abstract
The goal of this study was to show the feasibility of step and shoot intensity-modulated radiation therapy pre-treatment quality control for patients using the electronic portal imaging device (iViewGT) fitted on a Sli+ linac (Elekta Oncology Systems, Crawley, UK) instead of radiographic films. Since the beginning of intensity-modulated radiation therapy treatments, the dosimetric quality control necessary before treating each new patient has been a time-consuming and therefore costly obligation. In order to fully develop this technique, it seems absolutely essential to reduce the cost of these controls, especially the linac time. Up to now, verification of the relative dosimetry field by field has been achieved by acquiring radiographic films in the isocenter plane and comparing them to the results of the XiO planning system (Computerized Medical Systems, Missouri, USA) using RIT113 v4.1 software (Radiological Imaging Technology, Colorado, USA). A qualitative and quantitative evaluation was realised for every field of every patient. A quick and simple procedure was put into place to be able to make the same verifications using portal images. This new technique is not a modification of the overall methodology of analysis. The results achieved by comparing the measurement with the electronic portal imaging device and the calculation with the treatment planning system were in line with those achieved with the films for all indicators we studied (isodoses, horizontal and vertical dose profiles and gamma index).
Collapse
Affiliation(s)
- G Delpon
- Service de physique médicale, CLCC Nantes Atlantique, Nantes Saint-Herblain, France.
| | | | | | | | | |
Collapse
|
14
|
Isambert A, Beaudré A, Ferreira I, Lefkopoulos D. [Quality assurance of a virtual simulation software: application to IMAgo and SIMAgo (ISOgray)]. Cancer Radiother 2007; 11:178-87. [PMID: 17418608 DOI: 10.1016/j.canrad.2007.03.001] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2006] [Revised: 02/09/2007] [Accepted: 03/06/2007] [Indexed: 10/23/2022]
Abstract
PURPOSE Virtual simulation process is often used to prepare three dimensional conformal radiation therapy treatments. As the quality of the treatment is widely dependent on this step, it is mandatory to perform extensive controls on this software before clinical use. The tests presented in this work have been carried out on the treatment planning system ISOgray (DOSIsoft), including the delineation module IMAgo and the virtual simulation module SIMAgo. MATERIAL AND METHODS According to our experience, the most relevant controls of international protocols have been selected. These tests mainly focused on measuring and delineation tools, virtual simulation functionalities, and have been performed with three phantoms: the Quasar Multi-Purpose Body Phantom, the Quasar MLC Beam Geometry Phantom (Modus Medical Devices Inc.) and a phantom developed at Hospital Tenon. RESULTS No major issues have been identified while performing the tests. These controls have emphasized the necessity for the user to consider with a critical eye the results displayed by a virtual simulation software. The contrast of visualisation, the slice thickness, the calculation and display mode of 3D structures used by the software are many factors of uncertainties. CONCLUSION A virtual simulation software quality assurance procedure has been written and applied on a set of CT images. Similar tests have to be performed periodically and at minimum at each change of major version.
Collapse
Affiliation(s)
- A Isambert
- Service de physique médicale, institut Gustave-Roussy, 39, rue Camille-Desmoulins, 94805 Villejuif cedex, France.
| | | | | | | |
Collapse
|
15
|
Lefkopoulos D, Ferreira I, Isambert A, Le Péchoux C, Mornex F. Présent et avenir de la radiothérapie guidée par l'image (IGRT) et ses applications possibles dans le traitement des cancers bronchiques. Cancer Radiother 2007; 11:23-31. [PMID: 17113331 DOI: 10.1016/j.canrad.2006.10.001] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
These last years, the new irradiation techniques as the conformal 3D radiotherapy and the IMRT are strongly correlated with the technological developments in radiotherapy. The rigorous definition of the target volume and the organs at risk required by these irradiation techniques, imposed the development of various image guided patient positioning and target tracking techniques. The availability of these imaging systems inside the treatment room has lead to the exploration of performing real-time adaptive radiation therapy. In this paper we present the different image guided radiotherapy (IGRT) techniques and the adaptive radiotherapy (ART) approaches. IGRT developments are focused in the following areas: 1) biological imaging for better definition of tumor volume; 2) 4D imaging for modeling the intra-fraction organ motion; 3) on-board imaging system or imaging devices registered to the treatment machines for inter-fraction patient localization; and 4) treatment planning and delivery schemes incorporating the information derived from the new imaging techniques. As this paper is included in the "Cancer-Radiotherapie" special volume dedicated to the lung cancers, in the description of the different IGRT techniques we try to present the lung tumors applications when this is possible.
Collapse
Affiliation(s)
- D Lefkopoulos
- Service de physique médicale, institut Gustave-Roussy, 39, rue Camille-Desmoulins, 94805 Villejuif cedex, France.
| | | | | | | | | |
Collapse
|
16
|
de Crevoisier R, Lagrange JL, Messai T, M'Barek B, Lefkopoulos D. Dispositifs de repositionnement prostatique sous l'accélérateur linéaire. Cancer Radiother 2006; 10:394-401. [PMID: 17035061 DOI: 10.1016/j.canrad.2006.09.002] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The development of sophisticated conformal radiation therapy techniques for prostate cancer, such as intensity-modulated radiotherapy, implies precise and accurate targeting. Inter- and intrafraction prostate motion can be significant and should be characterized, unless the target volume may occasionally be missed. Indeed, bony landmark-based portal imaging does not provide the positional information for soft-tissue targets (prostate and seminal vesicles) or critical organs (rectum and bladder). In this article, we describe various prostate localization systems used before or during the fraction: rectal balloon, intraprostatic fiducials, ultrasound-based localization, integrated CT/linear accelerator system, megavoltage or kilovoltage cone-beam CT, Calypso 4D localization system tomotherapy, Cyberknife and Exactrac X-Ray 6D. The clinical benefit in using such prostate localization tools is not proven by randomized studies and the feasibility has just been established for some of these techniques. Nevertheless, these systems should improve local control by a more accurate delivery of an increased prescribed dose in a reduced planning target volume.
Collapse
Affiliation(s)
- R de Crevoisier
- Département de Radiothérapie, Institut Gustave-Roussy, 39, Rue Camille-Desmoulins, 94805 Villejuif, France.
| | | | | | | | | |
Collapse
|