1
|
Chaudhary G, Bhandari M, Chandra S, Pradhan A, Roy S, Singh V, Jaiswal V, Vishwakarma P, Dwivedi SK. Curious case of stent loss managed by a novel escort guiding technique. J Cardiovasc Med (Hagerstown) 2023; 24:271-276. [PMID: 36938797 DOI: 10.2459/jcm.0000000000001449] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/21/2023]
Affiliation(s)
| | | | | | | | - Shubhajeet Roy
- Faculty of Medical Sciences, King George's Medical University, Lucknow, Uttar Pradesh, India
| | - Vaishali Singh
- Faculty of Medical Sciences, King George's Medical University, Lucknow, Uttar Pradesh, India
| | - Vikash Jaiswal
- Department of Cardiology, Larkin Community Hospital, South Miami, Florida, USA
| | | | | |
Collapse
|
2
|
Hammami R, Ellouze T, Bahloul A, Abid L. A ruptured balloon shaft during an angioplasty. Clin Case Rep 2022; 10:e6600. [PMID: 36483885 PMCID: PMC9723256 DOI: 10.1002/ccr3.6600] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Revised: 08/29/2022] [Accepted: 10/06/2022] [Indexed: 12/12/2022] Open
Abstract
We report a case of balloon shaft rupture during percutaneous coronary intervention. Although the entrapped balloon was not yet deflated when the complication occurred, we successfully retrieved it percutaneously using a trapping technique. This case described a cheap and straightforward technique of device retrieval that helped save our patient.
Collapse
Affiliation(s)
- Rania Hammami
- Hedi Chaker Hospital Cardiology Department of SfaxSfaxTunisia
- Faculty of Medicine of SfaxUniversity of SfaxSfaxTunisia
| | - Tarek Ellouze
- Hedi Chaker Hospital Cardiology Department of SfaxSfaxTunisia
- Faculty of Medicine of SfaxUniversity of SfaxSfaxTunisia
| | - Amine Bahloul
- Hedi Chaker Hospital Cardiology Department of SfaxSfaxTunisia
- Faculty of Medicine of SfaxUniversity of SfaxSfaxTunisia
| | - Leila Abid
- Hedi Chaker Hospital Cardiology Department of SfaxSfaxTunisia
- Faculty of Medicine of SfaxUniversity of SfaxSfaxTunisia
| |
Collapse
|
3
|
Gasparini GL, Sanz-Sanchez J, Regazzoli D, Boccuzzi G, Oreglia JA, Gagnor A, Mazzarotto P, Belli G, Garbo R. Device entrapment during percutaneous coronary intervention of chronic total occlusions: incidence and management strategies. EUROINTERVENTION 2021; 17:212-219. [PMID: 32894229 PMCID: PMC9724869 DOI: 10.4244/eij-d-20-00781] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 09/04/2020] [Indexed: 11/23/2022]
Abstract
BACKGROUND Equipment delivery in chronic total occlusion (CTO) percutaneous coronary intervention (PCI) can be challenging and it is associated with a higher risk of device entrapment. Data regarding the incidence of device entrapment during CTO PCI are lacking. AIMS The aim of this study was to describe the incidence and procedural characteristics of device entrapment in patients undergoing PCI for CTOs and discuss management strategies for dealing with it. METHODS Device entrapment was characterised in a large consecutive series of 2,361 CTO PCI cases performed by five high-volume CTO Italian operators between January 2015 and January 2020. RESULTS Device entrapment occurred in 36 out of 2,361 cases (1.5%) and consisted of coronary guidewires in 13 (0.5%), microcatheters in 6 (0.2%), balloons in 6 (0.2%), rotational atherectomy burrs in 10 (0.4%) and guiding catheter extension in 1 patient (0.04%). Complete device retrieval was achieved in 63.9%, with at least partial removal of material in 97.2%. Vessel recanalisation was still possible in 86.1% of cases even after device entrapment. Intraprocedural myocardial infarction occurred in 3 patients (8.3%), tamponade with urgent pericardiocentesis in 1 (2.8%) and emergency surgical removal of the entrapped device in 1 patient (2.8%). Mean radiation dose was 4.7±2.3 Gy. At 30-day follow-up, one patient died with stent thrombosis of a non-target vessel and another required repeat percutaneous revascularisation. CONCLUSIONS Device entrapment during CTO revascularisations is a rare but potentially severe complication. We describe and discuss current techniques of percutaneous retrieval that can be employed to achieve procedural success safely.
Collapse
|
4
|
Doll JA, Hira RS, Kearney KE, Kandzari DE, Riley RF, Marso SP, Grantham JA, Thompson CA, McCabe JM, Karmpaliotis D, Kirtane AJ, Lombardi W. Management of Percutaneous Coronary Intervention Complications: Algorithms From the 2018 and 2019 Seattle Percutaneous Coronary Intervention Complications Conference. Circ Cardiovasc Interv 2020; 13:e008962. [PMID: 32527193 DOI: 10.1161/circinterventions.120.008962] [Citation(s) in RCA: 39] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Complications of percutaneous coronary intervention (PCI) may have significant impact on patient survival and healthcare costs. PCI procedural complexity and patient risk are increasing, and operators must be prepared to recognize and treat complications, such as perforations, dissections, hemodynamic collapse, no-reflow, and entrapped equipment. Unfortunately, few resources exist to train operators in PCI complication management. Uncertainty regarding complication management could contribute to the undertreatment of patients with high-complexity coronary disease. We, therefore, coordinated the Learning From Complications: How to Be a Better Interventionalist courses to disseminate the collective experience of high-volume PCI operators with extensive experience in chronic total occlusion and high-risk PCI. From these conferences in 2018 and 2019, we developed algorithms that emphasize early recognition, effective treatment, and team-based care of PCI complications. We think that an algorithmic approach will result in a logical and systematic response to life-threatening complications. This construct may be useful for operators who plan to perform complex PCI procedures.
Collapse
Affiliation(s)
- Jacob A Doll
- University of Washington, Seattle, WA (J.A.D., R.S.H., K.E.K., J.M.M., W.L.).,VA Puget Sound Health Care System, Seattle, WA (J.A.D.)
| | - Ravi S Hira
- University of Washington, Seattle, WA (J.A.D., R.S.H., K.E.K., J.M.M., W.L.)
| | - Kathleen E Kearney
- University of Washington, Seattle, WA (J.A.D., R.S.H., K.E.K., J.M.M., W.L.)
| | | | - Robert F Riley
- The Christ Hospital Health Network, Cincinnati, OH (R.F.R.)
| | - Steven P Marso
- HCA Midwest Health Heart and Vascular Institute, Overland Park, KS (S.P.M.)
| | - James A Grantham
- Saint Luke's Mid America Heart Institute, Kansas City, MO (J.A.G.).,University of Missouri-Kansas City, Kansas City, MO (J.A.G.)
| | | | - James M McCabe
- University of Washington, Seattle, WA (J.A.D., R.S.H., K.E.K., J.M.M., W.L.)
| | | | - Ajay J Kirtane
- Columbia University Medical Center, New York, NY (D.K., A.J.K.)
| | - William Lombardi
- University of Washington, Seattle, WA (J.A.D., R.S.H., K.E.K., J.M.M., W.L.)
| |
Collapse
|
5
|
Piayda K, Hellhammer K, Veulemans V, Zeus T. Valvuloplasty balloon entrapment in a self-expanding aortic valve stent frame after inadvertent wire passage through the outflow struts. Catheter Cardiovasc Interv 2019; 93:174-177. [PMID: 30244518 DOI: 10.1002/ccd.27858] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/02/2018] [Revised: 08/06/2018] [Accepted: 08/12/2018] [Indexed: 11/08/2022]
Abstract
Transcatheter aortic valve replacement (TAVR) is a leading-edge therapy option for patients with severe aortic stenosis (AS) and high surgical risk. However, this minimally invasive procedure is associated with specific complications that may be life-threatening. Valvuloplasty balloon entrapment during postdilatation in transcatheter self-expanding aortic valve stent frames has not yet been a focus of interest in this context. Although it is a rare event, it may critically influence outcome, and different management strategies can be considered. Hereafter, we present the case of a 67-year-old male who underwent transfemoral TAVR and subsequent postdilatation. The valvuloplasty balloon was entrapped in the self-expanding aortic valve stent frame after inadvertent wire passage through the outflow struts. Since surgical risk was high, we preferred a percutaneous approach and extracted the entrapped balloon with high traction force under rapid pacing after valve stabilization with another balloon, which was placed in the annular position.
Collapse
Affiliation(s)
- Kerstin Piayda
- Division of Cardiology, Pulmonology and Vascular Medicine, Heinrich Heine University, Medical Faculty, Düsseldorf, Germany
| | - Katharina Hellhammer
- Division of Cardiology, Pulmonology and Vascular Medicine, Heinrich Heine University, Medical Faculty, Düsseldorf, Germany
| | - Verena Veulemans
- Division of Cardiology, Pulmonology and Vascular Medicine, Heinrich Heine University, Medical Faculty, Düsseldorf, Germany
| | - Tobias Zeus
- Division of Cardiology, Pulmonology and Vascular Medicine, Heinrich Heine University, Medical Faculty, Düsseldorf, Germany
| |
Collapse
|