Cuman M, Clemente A, Celi S, Santoro G. 3D model-guided transcatheter closure of ascending aorta pseudoaneurysm with the novel Amplatzer Trevisio intravascular delivery system.
Catheter Cardiovasc Interv 2021;
99:140-144. [PMID:
34463417 DOI:
10.1002/ccd.29937]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/09/2021] [Revised: 08/07/2021] [Accepted: 08/21/2021] [Indexed: 11/12/2022]
Abstract
Ascending aorta pseudoaneurysm (AAP) is a rare but life-threatening complication of atherosclerosis, endocarditis, chest trauma, transcatheter or cardio-thoracic procedures. Since surgical repair is burdened by high morbidity and mortality, percutaneous closure is nowadays considered a valuable cost-effective therapeutic alternative. Due to unpredictability and complexity of local anatomy, no standardized technique and device are advised. In this setting, 3D printing technology could significantly help in planning trans-catheter approach. This article reports on a 3D printed model-guided percutaneous closure of a huge AAP using an Amplatzer Septal Occluder (Abbott, Plymouth MN) implanted by the recently commercialized Amplatzer Trevisio Intravascular Delivery System.
Collapse