1
|
Bibi S, Khan A, Khan AH, Khan MN, Mushtaq S, Rashid SA. Primary percutaneous coronary intervention in CAD patients: A comparison of major adverse cardiovascular events of second- and third-generation drug-eluting stents. Front Pharmacol 2022; 13:900798. [PMID: 36467026 PMCID: PMC9709248 DOI: 10.3389/fphar.2022.900798] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2022] [Accepted: 10/21/2022] [Indexed: 08/30/2023] Open
Abstract
Background: Biodegradable polymer (BP) drug-eluting stents (DES) have been introduced as a novel solution to the problems of durable polymer (DP) stents. In Pakistan, very few studies are available for the treatment intervention in post-primary percutaneous coronary intervention (PPCI) patients. Our study will compare the major adverse cardiovascular events (MACEs) and their predictors in patients with coronary artery disease (CAD) undergoing PPCI with second- or third-generation DES. Methodology: An observational, retrospective, cohort study was carried out on CAD patients undergoing PPCI with either second- (DP-XIENCE Prime/XIENCE Xpedition) or third-generation (BP-BioMatrix NeoFlex/BioMatrix Alpha) DES. MACEs were assessed after 1 year of PPCI procedure in 341 patients and screened as per inclusion/exclusion criteria (167 in the second-generation group and 174 in the third-generation group). Results: The number of male patients (86.2%) was more than female patients in our study population. MACEs were reported in 4.19% patients after 1 year duration, and the percentage of MACEs was more in the second-generation DES group (4.77%) than in the third-generation group (3.44%); however, statistical analysis has not found any significant difference (p = 0.534). The rate of myocardial infarction (1.19% vs. 0.57%) and stent thrombosis (1.8% vs. 1.15%) was more in the second-generation DES group. However, restenosis (1.19% vs. 1.15%) and cardiac death (0.59% vs. 0.57%) were almost same in both groups. A significant association was found between MACEs and diabetes mellitus (p = 0.025), hypertension (p = 0.035), smoking (p = 0.008), and a family history of CAD (p = 0.018). Conclusion: BP-BioMatrix and DP-XIENCE DES have comparable clinical outcomes. Findings of the current study will assist the policy makers and healthcare providers in the rationalization of scarce resources and evidence-based patient care. However, longer follow-up studies are required for convincing results.
Collapse
Affiliation(s)
- Salma Bibi
- Department of Pharmacy, Quaid-i-Azam University, Islamabad, Pakistan
| | - Amjad Khan
- Department of Pharmacy, Quaid-i-Azam University, Islamabad, Pakistan
| | - Amer Hayat Khan
- Discipline of Clinical Pharmacy, School of Pharmaceutical Sciences, Universiti Sains Malaysia, George Town, Penang, Malaysia
| | - Muhammad Niaz Khan
- Department of Interventional Cardiology, Hayatabad Medical Complex, Peshawar, Pakistan
| | - Saima Mushtaq
- Department of Healthcare Biotechnology, Atta-ur-Rahman School of Applied Biosciences, National University of Sciences and Technology, Islamabad, Pakistan
| | - Sheikh Abdur Rashid
- Gomal Center of Pharmaceutical Sciences, Faculty of Pharmacy, Gomal University, D.I.Khan, Pakistan
| |
Collapse
|
2
|
Vallejo-Zamora JA, Vega-Cantu YI, Rodriguez C, Cordell GA, Rodriguez-Garcia A. Drug-Eluting, Bioresorbable Cardiovascular Stents─Challenges and Perspectives. ACS APPLIED BIO MATERIALS 2022; 5:4701-4717. [PMID: 36150217 DOI: 10.1021/acsabm.2c00551] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Globally, the leading causes of natural death are attributed to coronary heart disease and type 1 and type 2 diabetes. High blood pressure levels, high cholesterol levels, smoking, and poor eating habits lead to the agglomeration of plaque in the arteries, reducing the blood flow. The implantation of devices used to unclog vessels, known as stents, sometimes results in a lack of irrigation due to the excessive proliferation of endothelial tissue within the blood vessels and is known as restenosis. The use of drug-eluting stents (DESs) to deliver antiproliferative drugs has led to the development of different encapsulation techniques. However, due to the potency of the drugs used in the initial stent designs, a chronic inflammatory reaction of the arterial wall known as thrombosis can cause a myocardial infarction (MI). One of the most promising drugs to reduce this risk is everolimus, which can be encapsulated in lipid systems for controlled release directly into the artery. This review aims to discuss the current status of stent design, fabrication, and functionalization. Variables such as the mechanical properties, metals and their alloys, drug encapsulation and controlled elution, and stent degradation are also addressed. Additionally, this review covers the use of polymeric surface coatings on stents and the recent advances in layer-by-layer coating and drug delivery. The advances in nanoencapsulation techniques such as liposomes and micro- and nanoemulsions and their functionalization in bioresorbable, drug-eluting stents are also highlighted.
Collapse
Affiliation(s)
- Julio A Vallejo-Zamora
- Tecnologico de Monterrey, Escuela de Ingeniería y Ciencias, Ave. Eugenio Garza Sada 2501, Monterrey, Nuevo León64849, Mexico
| | - Yadira I Vega-Cantu
- Tecnologico de Monterrey, Escuela de Ingeniería y Ciencias, Ave. Eugenio Garza Sada 2501, Monterrey, Nuevo León64849, Mexico
| | - Ciro Rodriguez
- Tecnologico de Monterrey, Escuela de Ingeniería y Ciencias, Ave. Eugenio Garza Sada 2501, Monterrey, Nuevo León64849, Mexico
- Laboratorio Nacional de Manufactura Aditiva y Digital (MADIT), Apodaca, Nuevo León66629, Mexico
| | - Geoffrey A Cordell
- Natural Products, Inc., Evanston, Illinois60201, United States
- College of Pharmacy, University of Florida, Gainesville, Florida32610, United States
| | - Aida Rodriguez-Garcia
- Tecnologico de Monterrey, Escuela de Ingeniería y Ciencias, Ave. Eugenio Garza Sada 2501, Monterrey, Nuevo León64849, Mexico
- Universidad Autónoma de Nuevo León, Facultad de Ciencias Biológicas, Instituto de Biotecnología, Ciudad Universitaria, Ave. Pedro de Alba S/N, San Nicolás de los Garza, Nuevo León66455, Mexico
| |
Collapse
|
3
|
Mattke S, Hanson M, Bentele M, Kandzari DE. Cost and Mortality Implications of Lower Event Rates After Implantation of an Ultrathin-Strut Coronary Stent Compared With a Thin-Strut Stent Over Four Years. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2020; 21:835-842. [PMID: 31954661 DOI: 10.1016/j.carrev.2019.12.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2019] [Revised: 12/13/2019] [Accepted: 12/13/2019] [Indexed: 10/25/2022]
Abstract
BACKGROUND The recent BIOFLOW V trial (ClinicalTrials.gov: NCT02389946) showed that revascularization with an ultrathin strut, bioresorbable polymer sirolimus-eluting stent (BP SES) was associated with lower rates of clinically driven target lesion revascularization (TLR) and target vessel-related myocardial infarction (TVMI) at 24-month follow-up than that with a thin strut, durable polymer everolimus-eluting stent (DP EES). We simulated the impact on cost and mortality. METHODS AND RESULTS We projected the impact of the lower adverse event rates from a U.S. health system perspective over a 48-month horizon with a Markov model using event data from the BIOFLOW V trial and estimates for costs and excess mortality due to adverse events from published sources. All cost estimates were CPI-adjusted to 2018 US$ and future cost discounted by 3%. We estimated that use of BP SES compared to DP EES was associated with cumulative net reductions in medical cost of $2429 per patient over 48 months. Peri-procedural TVMI contributed $124 (5%), TLR in patients without TVMI $810 (33%) and spontaneous TVMI $1496 (62%) of cost. Use of BP SES compared to DP EES was associated with 2603 fewer deaths in one million patients over four years, corresponding to a relative risk reduction of 6%. CONCLUSIONS Lower adverse event rates associated with revascularization using BP SES translate into reductions in direct medical cost and mortality. Most of the cost reduction is attributed to reduction in spontaneous TVMI. Given the high volume of coronary procedures, such results are an important consideration for patients, clinicians and payers.
Collapse
Affiliation(s)
- Soeren Mattke
- University of Southern California, Los Angeles, CA, USA; Benecit Research, Newton, MA, USA.
| | - Mark Hanson
- University of Southern California, Los Angeles, CA, USA; Benecit Research, Newton, MA, USA
| | | | | |
Collapse
|
4
|
The Orsiro Ultrathin, Bioresorbable-Polymer Sirolimus-Eluting Stent: A Review of Current Evidence. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2020; 21:540-548. [PMID: 31952919 DOI: 10.1016/j.carrev.2019.12.039] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2019] [Revised: 12/19/2019] [Accepted: 12/30/2019] [Indexed: 11/23/2022]
Abstract
Advances in stent design and the development of bioresorbable polymers have allowed the development of novel stent technologies such as the Orsiro bioresorbable-polymer sirolimus eluting stent (BP-SES). Over several noninferiority trials, the BP-SES has demonstrated itself to be a safe and effective therapy for obstructive coronary artery disease. This article reviews the current evidence of the efficacy of the BP-SES and examines its performance in high-risk populations, such as patients presenting with ST-segment myocardial infarction, chronic total occlusions, diabetes, and small vessel disease.
Collapse
|