1
|
Maffey MW, Bagur R. Dedicated Balloon Techniques for Coronary Calcium Modification. Interv Cardiol 2024; 19:e13. [PMID: 39221062 PMCID: PMC11363055 DOI: 10.15420/icr.2024.06] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2024] [Accepted: 06/09/2024] [Indexed: 09/04/2024] Open
Abstract
Coronary calcification represents a significant technical challenge in percutaneous coronary intervention and is associated with worse clinical outcomes. Fortunately, a number of balloon-assisted technologies are available to aid in the management of coronary calcification before stenting. Adequate lesion preparation is crucial in the successful management of calcified coronary lesions. Balloon-based techniques can be a safe and effective method of lesion preparation and, as such, are an integral part of an interventionalist's armamentarium. In this mini-review, we focus on the use of non-compliant balloons, super high-pressure non-compliant balloons, cutting balloons, scoring balloons and intravascular lithotripsy.
Collapse
Affiliation(s)
- Max W Maffey
- Complex, High-Risk and Indicated Percutaneous Coronary Interventions (CHIP) and Chronic Total Occlusion (CTO) Program, Interventional Cardiology, London Health Sciences Centre, Division of Cardiology, Department of Medicine, Western University London, ON, Canada
| | - Rodrigo Bagur
- Complex, High-Risk and Indicated Percutaneous Coronary Interventions (CHIP) and Chronic Total Occlusion (CTO) Program, Interventional Cardiology, London Health Sciences Centre, Division of Cardiology, Department of Medicine, Western University London, ON, Canada
| |
Collapse
|
2
|
Hansen KN, Maehara A, Noori M, Trøan J, Fallesen CO, Hougaard M, Ellert-Gregersen J, Veien KT, Junker A, Hansen HS, Lassen JF, Jensen LO. Optimal lesion preparation before implantation of a Magmaris bioresorbable scaffold in patients with coronary artery stenosis: Rationale, design and methodology of the OPTIMIS study. Contemp Clin Trials Commun 2024; 38:101260. [PMID: 38384894 PMCID: PMC10879808 DOI: 10.1016/j.conctc.2024.101260] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Revised: 01/02/2024] [Accepted: 01/15/2024] [Indexed: 02/23/2024] Open
Abstract
Introduction Percutaneous coronary intervention with implantation of a bioresorbable scaffold (BRS) provide the vessel support for a limited period allowing the vessel to restore normal vasomotion after degradation of the BRS, opposed to treatment with drug-eluting stents where the metal persist in the vessel wall. Late lumen loss and reduction in lumen area after implantation have been reported. The purpose of this study was to investigate whether intense pre-dilatation before BRS implantation resulted in less reduction of minimal lumen area at 6- and 12-month follow-up after implantation of a Magmaris BRS (MgBRS). Coronary imaging with optical coherence tomography (OCT) and intravascular ultrasound (IVUS) was assessed to track changes in lumen and vessel dimensions. Methods The prospective Optimal lesion PreparaTion before Implantation of the Magmaris bioresorbable scaffold In patients with coronary artery Stenosis (OPTIMIS) study randomly assigned eighty-two patients with chronic coronary syndrome to two pre-dilatation treatment strategies. Patients were randomized in a 1:1 ratio to pre-dilatation with either a non-compliant scoring balloon or a standard non-compliant balloon prior to implantation of a MgBRS. The treated segment was evaluated with OCT and IVUS at baseline, after 6 and 12 months to assess changes in lumen and vessel dimensions. The hypothesis was that more intense pre-dilatation with a non-compliant scoring balloon before MgBRS implantation can reduce the risk of late lumen reduction compared to standard pre-dilatation. The power calculation used expected MLA after 6 months (6.22 mm2 for the scoring balloon and 5.01 mm2 for the standard non-compliant balloon), power of 80 %, significance level of 0.05 and expected drop-out rate of 15 %, requiring 82 patients to be enrolled. Results Eighty-two patients were included in the study. Enrollment was from December 2020 to September 2023. Conclusion The hypothesis was that more intense pre-dilatation with a non-compliant scoring balloon before MgBRS implantation can reduce the risk of late lumen reduction compared to standard pre-dilatation.
Collapse
Affiliation(s)
- Kirstine Nørregaard Hansen
- Department of Cardiology, Odense University Hospital, Odense, Denmark
- University of Southern Denmark, Odense, Denmark
| | - Akiko Maehara
- Cardiovascular Research Foundation, New York Presbyterian Hospital, New York, USA
| | - Manijeh Noori
- Department of Cardiology, Odense University Hospital, Odense, Denmark
- University of Southern Denmark, Odense, Denmark
| | - Jens Trøan
- Department of Cardiology, Odense University Hospital, Odense, Denmark
| | | | - Mikkel Hougaard
- Department of Cardiology, Odense University Hospital, Odense, Denmark
| | | | | | - Anders Junker
- Department of Cardiology, Odense University Hospital, Odense, Denmark
| | - Henrik Steen Hansen
- Department of Cardiology, Odense University Hospital, Odense, Denmark
- University of Southern Denmark, Odense, Denmark
| | - Jens Flensted Lassen
- Department of Cardiology, Odense University Hospital, Odense, Denmark
- University of Southern Denmark, Odense, Denmark
| | - Lisette Okkels Jensen
- Department of Cardiology, Odense University Hospital, Odense, Denmark
- University of Southern Denmark, Odense, Denmark
| |
Collapse
|
3
|
Bernardi M, Morello A, Galli M. Complex percutaneous coronary intervention: what is the role of new-generation scoring balloons? Minerva Cardiol Angiol 2022; 70:686-688. [PMID: 36256437 DOI: 10.23736/s2724-5683.22.06123-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Affiliation(s)
- Marco Bernardi
- Department of Clinical, Internal Medicine, Anesthesiology and Cardiovascular Sciences, Sapienza University, Rome, Italy
| | - Alberto Morello
- Interventional Cardiovascular Unit, Pineta Grande Hospital, Castel Volturno, Caserta, Italy
| | | |
Collapse
|