1
|
Qi X, Liu P, Yao F, Zhao M, Shen X, Wang Z. Exploring the synchronized effect of MWCNT/X-manganate (X-Cu, Zn) nanocomposite for the sensitive and selective electrochemical detection of Hg(II) and Pb(II) in water. ANAL SCI 2024:10.1007/s44211-024-00652-1. [PMID: 39212898 DOI: 10.1007/s44211-024-00652-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2024] [Accepted: 08/11/2024] [Indexed: 09/04/2024]
Abstract
The presence of heavy metal ions in the environment is a long-lasting problem that requires the simultaneous detection of Hg(II) and Pb(II) which is both vital and challenging. This present study examines a simplified and effective approach for synthesizing multi-walled carbon nanotube-copper manganese oxide (MWCNT-CuMn2O4) and multi-walled carbon nanotube-zinc manganese oxide (MWCNT-ZnMn2O4) nanocomposites for electrochemical detection of heavy metal ions. The nanocomposites MWCNT-CuMn2O4 and MWCNT-ZnMn2O4 exceptional electrochemical performance was evaluated using Square Wave Anodic Stripping Voltammetry (SWASV). The fabricated MWCNT-ZnMn2O4 demonstrated lower values of Electrochemical Impedance Spectroscopy (EIS) with charge transfer resistance (Rct) of approximately 34.13 Ω. Remarkably, the MWCNT-ZnMn2O4 electrochemical sensor exhibited the widest linear ranges of 0.5-10 μM with sensitive detection limits (0.011 μM for Hg(II) and 0.014 μM for Pb(II)). Interestingly, the MWCNT-ZnMn2O4 sensor showed excellent capability in detecting Hg(II) and Pb(II) in real water samples with a recovery percentage of 94.1% and 91.3%. Overall, the MWCNT-ZnMn2O4 modified GCE showcased superior selectivity, sensitivity, reproducibility, stability, and repeatability.
Collapse
Affiliation(s)
- Xingpu Qi
- School of Food Science and Technology, Jiangsu Agri-animal Husbandry Vocational College, No. 8, Fenghuang East Road, Taizhou, 225300, People's Republic of China
| | - Ping Liu
- School of Food Science and Technology, Jiangsu Agri-animal Husbandry Vocational College, No. 8, Fenghuang East Road, Taizhou, 225300, People's Republic of China
| | - Fang Yao
- School of Food Science and Technology, Jiangsu Agri-animal Husbandry Vocational College, No. 8, Fenghuang East Road, Taizhou, 225300, People's Republic of China
| | - Mengli Zhao
- School of Food Science and Technology, Jiangsu Agri-animal Husbandry Vocational College, No. 8, Fenghuang East Road, Taizhou, 225300, People's Republic of China
| | - Xuanyu Shen
- School of Food Science and Technology, Jiangsu Agri-animal Husbandry Vocational College, No. 8, Fenghuang East Road, Taizhou, 225300, People's Republic of China
| | - Zhengyun Wang
- School of Food Science and Technology, Jiangsu Agri-animal Husbandry Vocational College, No. 8, Fenghuang East Road, Taizhou, 225300, People's Republic of China.
| |
Collapse
|
2
|
Li B, Xie X, Meng T, Guo X, Li Q, Yang Y, Jin H, Jin C, Meng X, Pang H. Recent advance of nanomaterials modified electrochemical sensors in the detection of heavy metal ions in food and water. Food Chem 2024; 440:138213. [PMID: 38134834 DOI: 10.1016/j.foodchem.2023.138213] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2023] [Revised: 12/10/2023] [Accepted: 12/12/2023] [Indexed: 12/24/2023]
Abstract
As one of the main pollutants, heavy metal ions can accumulate in the human body and cause a cascade of damage. Electrochemical sensors provide great prospects for tracing heavy metal ions because of their properties of high sensitivity, low detection limits and fast response. Electrode surface modification materials play a key role in enhancing the performance of electrochemical sensors. Herein, we summarize in detail the recent work on electrochemical sensors modified by carbon nanomaterials (graphene and its derivatives, carbon nanofibers and carbon nanotubes), metal nanomaterials (gold, silver, bismuth and iron), complexes (MOFs, ZIFs and MXenes) and their composites for the detection of heavy metal ions (mainly include Cd(II), Hg(II), Pb(II), As(III), Cu(II) and Zn(II)) in food and water. The synthetic strategies, mechanisms, innovations, advantages, challenges and prospects of various electrode modification nanomaterials for the detection of heavy metal ions in food and water are discussed.
Collapse
Affiliation(s)
- Bing Li
- College of Tourism and Culinary Science, Yangzhou University, Jiangsu 225127, PR China; College of Food Science and Engineering, Yangzhou University, Yangzhou 225127, Jiangsu, PR China.
| | - Xiaomei Xie
- College of Tourism and Culinary Science, Yangzhou University, Jiangsu 225127, PR China
| | - Tonghui Meng
- College of Tourism and Culinary Science, Yangzhou University, Jiangsu 225127, PR China
| | - Xiaotian Guo
- College of Tourism and Culinary Science, Yangzhou University, Jiangsu 225127, PR China
| | - Qingzheng Li
- College of Tourism and Culinary Science, Yangzhou University, Jiangsu 225127, PR China
| | - Yuting Yang
- College of Tourism and Culinary Science, Yangzhou University, Jiangsu 225127, PR China
| | - Haixia Jin
- College of Tourism and Culinary Science, Yangzhou University, Jiangsu 225127, PR China
| | - Changhai Jin
- College of Food Science and Engineering, Yangzhou University, Yangzhou 225127, Jiangsu, PR China
| | - Xiangren Meng
- College of Tourism and Culinary Science, Yangzhou University, Jiangsu 225127, PR China.
| | - Huan Pang
- College of Chemistry and Chemical Engineering, Yangzhou University, Jiangsu, 225002, PR China.
| |
Collapse
|
3
|
Wang Y, Ren D, Zhang Y, Li J, Meng W, Tong B, Zhang J, Han C, Dai L. In-situ integrated electrodes of FeM-MIL-88/CP for simultaneous ultra-sensitive detection of dopamine and acetaminophen based on crystal engineering strategy. Anal Chim Acta 2023; 1283:341936. [PMID: 37977775 DOI: 10.1016/j.aca.2023.341936] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Revised: 09/30/2023] [Accepted: 10/19/2023] [Indexed: 11/19/2023]
Abstract
Designing and exploiting integrated electrodes is the current inevitable trend to realize the sustainable development of electrochemical sensors. In this work, a series of integrated electrodes prepared by in situ growing the second metal ion-modulated FeM-MIL-88 (M = Mn, Co and Ni) on carbon paper (CP) (FeM-MIL-88/CP) were constructed as the electrochemical sensing platforms for the simultaneous detection of dopamine (DA) and acetaminophen (AC). Among them, FeMn-MIL-88/CP exhibited the best sensing behaviors and achieved the trace detection for DA and AC owing to synergistic catalysis between Fe3+, Mn2+ and CP. The electrochemical sensor based on FeMn-MIL-88/CP showed ultra-high sensitivities of 2.85 and 7.46 μA μM-1 cm-2 and extremely low detection limits of 0.082 and 0.015 μM for DA and AC, respectively. The FeMn-MIL-88/CP also exhibited outstanding anti-interference ability, repeatability and stability, and satisfactory results were also obtained in the detection of actual samples. The mechanism of Mn2+ modulation on the electrocatalytic activity of FeMn-MIL-88/CP towards DA and AC was revealed for the first time through the density functional theory (DFT) calculations. Good adsorption energy and rapid electron transfer worked synergistically to improve the sensing performances of DA and AC. This work not only provided a high-performance integrated electrode for the sensing field, but also demonstrated the influencing factors of electrochemical sensing at the molecular levels, laying a theoretical foundation for the sustainable development of subsequent electrochemical sensing.
Collapse
Affiliation(s)
- Yue Wang
- College of Chemical Engineering, North China University of Science and Technology, Tangshan, 063009, China
| | - Dongmei Ren
- College of Chemical Engineering, North China University of Science and Technology, Tangshan, 063009, China
| | - Yan Zhang
- School of Environmental Science and Engineering, Tianjin University, Tianjin, 300350, China
| | - Junguo Li
- College of Metallurgy and Energy, North China University of Science and Technology, Tangshan, 063009, China
| | - Wei Meng
- College of Chemical Engineering, North China University of Science and Technology, Tangshan, 063009, China.
| | - Boran Tong
- College of Chemical Engineering, North China University of Science and Technology, Tangshan, 063009, China
| | - Jing Zhang
- College of Chemical Engineering, North China University of Science and Technology, Tangshan, 063009, China
| | - Chao Han
- College of Chemical Engineering, North China University of Science and Technology, Tangshan, 063009, China.
| | - Lei Dai
- College of Chemical Engineering, North China University of Science and Technology, Tangshan, 063009, China.
| |
Collapse
|
4
|
Hu M, He H, Xiao F, Liu C. Bi-MOF-Derived Carbon Wrapped Bi Nanoparticles Assembly on Flexible Graphene Paper Electrode for Electrochemical Sensing of Multiple Heavy Metal Ions. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:2069. [PMID: 37513081 PMCID: PMC10386677 DOI: 10.3390/nano13142069] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Revised: 07/08/2023] [Accepted: 07/10/2023] [Indexed: 07/30/2023]
Abstract
The development of nanohybrid with high electrocatalytic activity is of great significance for electrochemical sensing applications. In this work, we develop a novel and facile method to prepare a high-performance flexible nanohybrid paper electrode, based on nitrogen-doped carbon (NC) wrapped Bi nanoparticles (Bi-NPs) assembly derived from Bi-MOF, which are decorated on a flexible and freestanding graphene paper (GP) electrode. The as-obtained Bi-NPs encapsulated by an NC layer are uniform, and the active sites are increased by introducing a nitrogen source while preparing Bi-MOF. Owing to the synergistic effect between the high conductivity of GP electrode and the highly efficient electrocatalytic activity of Bi-NPs, the NC wrapped Bi-NPs (Bi-NPs@NC) modified GP (Bi-NPs@NC/GP) electrode possesses high electrochemically active area, rapid electron-transfer capability, and good electrochemical stability. To demonstrate its outstanding functionality, the Bi-NPs@NC/GP electrode has been integrated into a handheld electrochemical sensor for detecting heavy metal ions. The result shows that Zn2+, Cd2+, and Pb2+ can be detected with extremely low detection limits, wide linear range, high sensitivity, as well as good selectivity. Furthermore, it demonstrates outstanding electrochemical sensing performance in the simultaneous detection of Zn2+, Cd2+, and Pb2+. Finally, the proposed electrochemical sensor has achieved excellent repeatability, reproducibility, stability, and reliability in measuring real water samples, which will have great potential in advanced applications in environmental systems.
Collapse
Affiliation(s)
- Min Hu
- Key Laboratory of Material Chemistry for Energy Conversion and Storage, Ministry of Education, School of Chemistry and Chemical Engineering, Huazhong University of Science & Technology, Wuhan 430074, China
| | - Hu He
- Technology Inspection Center of Sheng Li Oil Filed, Dongying 257000, China
| | - Fei Xiao
- Key Laboratory of Material Chemistry for Energy Conversion and Storage, Ministry of Education, School of Chemistry and Chemical Engineering, Huazhong University of Science & Technology, Wuhan 430074, China
- Research Institution of Huazhong University of Science and Technology in Shenzhen, Shenzhen 518052, China
| | - Chen Liu
- Key Laboratory of Material Chemistry for Energy Conversion and Storage, Ministry of Education, School of Chemistry and Chemical Engineering, Huazhong University of Science & Technology, Wuhan 430074, China
| |
Collapse
|
5
|
Bao Q, Li G, Yang Z, Wei J, Cheng W, Qu Z, Lin L. A Time-Division Multiplexing Multi-Channel Micro-Electrochemical Workstation with Carbon-Based Material Electrodes for Online L-Trosine Detection. SENSORS (BASEL, SWITZERLAND) 2023; 23:6252. [PMID: 37514547 PMCID: PMC10386381 DOI: 10.3390/s23146252] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Revised: 07/02/2023] [Accepted: 07/07/2023] [Indexed: 07/30/2023]
Abstract
In the background of the rapid development of artificial intelligence, big data, IoT, 5G/6G, and other technologies, electrochemical sensors pose higher requirements for high-throughput detection. In this study, we developed a workstation with up to 10 channels, which supports both parallel signal stimulation and online electrochemical analysis functions. The platform was wired to a highly integrated Bluetooth chip used for wireless data transmission and can be visualized on a smartphone. We used this electrochemical test platform with carbon-graphene oxide/screen-printed carbon electrodes (CB-GO/SPCE) for the online analysis of L-tyrosine (Tyr), and the electrochemical performance and stability of the electrodes were examined by differential pulse voltammetry (DPV). The CB-GO-based screen-printed array electrodes with a multichannel electrochemical platform for Tyr detection showed a low detection limit (20 μM), good interference immunity, and 10-day stability in the range of 20-200 μM. This convenient electrochemical analytical device enables high-throughput detection and has good economic benefits that can contribute to the improvement of the accuracy of electrochemical analysis and the popularization of electrochemical detection methods in a wide range of fields.
Collapse
Affiliation(s)
- Qiwen Bao
- School of Precision Instrument and Optoelectronic Engineering, the State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, 92 Weijin Road, Tianjin 300072, China
| | - Gang Li
- School of Precision Instrument and Optoelectronic Engineering, the State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, 92 Weijin Road, Tianjin 300072, China
| | - Zhengchun Yang
- School of Electrical and Electronic Engineering, Tianjin Key Laboratory of Film Electronic & Communication Devices, Advanced Materials and Printed Electronics Center, Tianjin University of Technology, Tianjin 300384, China
| | - Jun Wei
- School of Materials Science and Engineering, Harbin Institute of Technology, Shenzhen 518055, China
| | - Wenbo Cheng
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
| | - Zilian Qu
- Beijing Information Technol Coll, Beijing 100015, China
| | - Ling Lin
- School of Precision Instrument and Optoelectronic Engineering, the State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, 92 Weijin Road, Tianjin 300072, China
| |
Collapse
|
6
|
Mohamad Nor N, Nasrul SN, Zakaria ND, Abdul Razak K. Simultaneous Sensing of Cd(II), Pb(II), and Cu(II) Using Gold Nanoparticle-Modified APTES-Functionalized Indium Tin Oxide Electrode: Effect of APTES Concentration. ACS OMEGA 2023; 8:16587-16599. [PMID: 37214679 PMCID: PMC10193388 DOI: 10.1021/acsomega.2c07085] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/03/2022] [Accepted: 04/20/2023] [Indexed: 05/24/2023]
Abstract
In this work, indium tin oxide (ITO) electrodes were functionalized with varying 3-aminopropyltriethoxysilane (APTES) concentration percentages (0.5, 0.75, 1.0, and 2.0 wt %) to obtain the optimum conditions for the assembly of the as-synthesized gold nanoparticles (AuNPs). The AuNP coverage, wettability, and electrochemical performance of the modified electrodes were evaluated. The AuNP/0.75% APTES-ITO-modified electrode exhibited uniform coverage of AuNPs and high electrochemical performance for the simultaneous detection of Cd(II), Pb(II), and Cu(II) ions. Under the optimum conditions, the AuNP/0.75% APTES-ITO-modified electrode showed a linear detection range of 5-120 ppb and limit of detection of 0.73, 0.90, and 0.49 ppb for the simultaneous detection of Cd(II), Pb(II), and Cu(II) ions, respectively, via square wave anodic stripping voltammetry. The modified electrode demonstrated good anti-interference toward other heavy metal ions, good reproducibility, and suitability for application in environmental sample analysis.
Collapse
Affiliation(s)
- Noorhashimah Mohamad Nor
- School
of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, 14300 Nibong Tebal, Pulau Pinang, Malaysia
| | - Siti Nasirah Nasrul
- School
of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, 14300 Nibong Tebal, Pulau Pinang, Malaysia
| | - Nor Dyana Zakaria
- NanoBiotechnology
Research & Innovation (NanoBRI), INFORMM,
Universiti Sains Malaysia, 11800 Gelugor, Pulau Pinang, Malaysia
| | - Khairunisak Abdul Razak
- School
of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, 14300 Nibong Tebal, Pulau Pinang, Malaysia
- NanoBiotechnology
Research & Innovation (NanoBRI), INFORMM,
Universiti Sains Malaysia, 11800 Gelugor, Pulau Pinang, Malaysia
| |
Collapse
|
7
|
Han M, Xie Y, Wang R, Li Y, Bian C, Xia S. 4-Mercaptopyridine-Modified Sensor for the Sensitive Electrochemical Detection of Mercury Ions. MICROMACHINES 2023; 14:739. [PMID: 37420972 DOI: 10.3390/mi14040739] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Revised: 03/16/2023] [Accepted: 03/25/2023] [Indexed: 07/09/2023]
Abstract
As a highly toxic heavy metal ion, mercury ion (Hg2+) pollution has caused serious harm to the environment and human health. In this paper, 4-mercaptopyridine (4-MPY) was selected as the sensing material and decorated on the surface of a gold electrode. Trace Hg2+ could be detected by both differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS) methods. The proposed sensor displayed a wide detection range from 0.01 μg/L to 500 μg/L with a low limit of detection (LOD) of 0.002 μg/L by EIS measurements. Combined with molecular simulations and electrochemical analyses, the chelating mechanism between Hg2+ and 4-MPY was explored. Through the analysis of binding energy (BE) values and stability constants, 4-MPY showed an excellent selectivity for Hg2+. In the presence of Hg2+, the coordination of Hg2+ with the pyridine nitrogen of 4-MPY was generated at the sensing region, which caused a change in the electrochemical activity of the electrode surface. Due to the strong specific binding capability, the proposed sensor featured excellent selectivity and an anti-interference capability. Furthermore, the practicality of the sensor for Hg2+ detection was validated with the samples of tap water and pond water, which demonstrated its potential application for on-site environmental detection.
Collapse
Affiliation(s)
- Mingjie Han
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100190, China
| | - Yong Xie
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100190, China
| | - Ri Wang
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100190, China
| | - Yang Li
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
| | - Chao Bian
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
| | - Shanhong Xia
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
| |
Collapse
|
8
|
Elsebai B, Ghica ME, Abbas MN, Brett CMA. Novel Amperometric Mercury-Selective Sensor Based on Organic Chelator Ionophore. Molecules 2023; 28:molecules28062809. [PMID: 36985781 PMCID: PMC10053095 DOI: 10.3390/molecules28062809] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 03/14/2023] [Accepted: 03/18/2023] [Indexed: 03/30/2023] Open
Abstract
A novel amperometric sensor for the direct determination of toxic mercury ions, Hg2+, based on the organic chelator ionophore N, N di (2-hydroxy-5-[(4-nitrophenyl)diazenyl]benzaldehyde) benzene-1,2-diamine (NDBD), and multiwalled carbon nanotubes (MWCNT) immobilized on a glassy carbon electrode surface was developed. The parameters influencing sensor performance including the ionophore concentration, the applied potential, and electrolyte pH were optimized. The sensor response to Hg2+ was linear between 1-25 µM with a limit of detection of 60 nM. Interferences from other heavy metal ions were evaluated and the sensor showed excellent selectivity towards Hg2+. The method was successfully applied to the determination of mercury ions in milk and water samples.
Collapse
Affiliation(s)
- Basant Elsebai
- Water Pollution Research Department, Environmental and Climate Changes Research Institute, National Research Centre, El-Buhouth St., Dokki, Giza 12622, Egypt
- Department of Chemistry, CEMMPRE, ARISE, University of Coimbra, 3004-535 Coimbra, Portugal
| | - Mariana Emilia Ghica
- Department of Chemistry, CEMMPRE, ARISE, University of Coimbra, 3004-535 Coimbra, Portugal
- Department of Chemical Engineering, CIEPQPF, University of Coimbra, 3030-790 Coimbra, Portugal
| | - Mohammed Nooredeen Abbas
- Applied Organic Chemistry Department, Chemical Industries Research Institute, National Research Centre, El-Buhouth St., Dokki, Giza 12622, Egypt
| | - Christopher M A Brett
- Department of Chemistry, CEMMPRE, ARISE, University of Coimbra, 3004-535 Coimbra, Portugal
| |
Collapse
|
9
|
A new aggregation-induced emission-based fluorescent probe for effective detection of Hg2+ and its multiple applications. CHINESE CHEM LETT 2023. [DOI: 10.1016/j.cclet.2023.108237] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/26/2023]
|
10
|
Tan R, Jiang P, Pan C, Pan J, Gao N, Cai Z, Wu F, Chang G, Xie A, He Y. Core-shell architectured NH 2-UiO-66@ZIF-8/multi-walled carbon nanotubes nanocomposite-based sensitive electrochemical sensor towards simultaneous determination of Pb 2+ and Cu 2. Mikrochim Acta 2022; 190:30. [PMID: 36525121 DOI: 10.1007/s00604-022-05599-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2022] [Accepted: 11/28/2022] [Indexed: 12/23/2022]
Abstract
Amino functionalized zirconium-based metal-organic framework (NH2-UiO-66) and zinc-based zeolitic imidazolate framework (ZIF-8) were integrated to develop a core-shell architectured hybrid material (NH2-UiO-66@ZIF-8, NU66@Z8). The morphology and structure evolutions of core-shell NU6@Z8 were investigated by FE-SEM, XRD, FTIR, and XPS. The NU66@Z8 combined with carboxylated multi-walled carbon nanotubes (CMWCNT) was deposited on a glassy carbon electrode (GCE) for fabricating an electrochemical platform towards detecting Pb2+ and Cu2+. The NU66@Z8/CMWCNT/GCE revealed significantly improved electrochemical performance for determination of Pb2+ and Cu2+ compared with the individual components, which can be attributed to the strong adsorption capacity, unique core-shell structure, and large electrochemical active surface area of NU66@Z8/CMWCNT. Under the optimal conditions, the developed sensor exhibited excellent sensing capability with a low limit of detection (Pb2+,1 nM; Cu2+, 10 nM) and a wide determination range (Pb2+,0.003-70 μM; Cu2+, 0.03-50 μM). The sensor showed high selectivity towards common interfering ions and good repeatability. The real sample recoveries of proposed sensor were in the range 95.0-103% for Pb2+ (RSD ≤ 5.3%) and 94.2-106% for Cu2+ (RSD ≤ 5.9%), suggesting that the NU66@Z8/CMWCNT is suitable for examining trace heavy metals in natural environment.
Collapse
Affiliation(s)
- Runan Tan
- Ministry-of-Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubei Key Laboratory of Polymer Materials, School of Materials Science and Engineering, Hubei University, No.368 Youyi Avenue, Wuchang, 430062, Wuhan, China
| | - Panpan Jiang
- Ministry-of-Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubei Key Laboratory of Polymer Materials, School of Materials Science and Engineering, Hubei University, No.368 Youyi Avenue, Wuchang, 430062, Wuhan, China
| | - Chuchu Pan
- Ministry-of-Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubei Key Laboratory of Polymer Materials, School of Materials Science and Engineering, Hubei University, No.368 Youyi Avenue, Wuchang, 430062, Wuhan, China
| | - Junzi Pan
- Ministry-of-Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubei Key Laboratory of Polymer Materials, School of Materials Science and Engineering, Hubei University, No.368 Youyi Avenue, Wuchang, 430062, Wuhan, China
| | - Nan Gao
- Ministry-of-Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubei Key Laboratory of Polymer Materials, School of Materials Science and Engineering, Hubei University, No.368 Youyi Avenue, Wuchang, 430062, Wuhan, China
| | - Zhiwei Cai
- Ministry-of-Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubei Key Laboratory of Polymer Materials, School of Materials Science and Engineering, Hubei University, No.368 Youyi Avenue, Wuchang, 430062, Wuhan, China
| | - Fan Wu
- School of Mechanical Engineering, Nanjing University of Science & Technology, Nanjing, 210094, China
| | - Gang Chang
- Ministry-of-Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubei Key Laboratory of Polymer Materials, School of Materials Science and Engineering, Hubei University, No.368 Youyi Avenue, Wuchang, 430062, Wuhan, China.
| | - Aming Xie
- School of Mechanical Engineering, Nanjing University of Science & Technology, Nanjing, 210094, China.
| | - Yunbin He
- Ministry-of-Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubei Key Laboratory of Polymer Materials, School of Materials Science and Engineering, Hubei University, No.368 Youyi Avenue, Wuchang, 430062, Wuhan, China.
| |
Collapse
|
11
|
Li L, Chen J, Xiao C, Luo Y, Zhong N, Xie Q, Chang H, Zhong D, Xu Y, Zhao M, Liao Q. Recent advances in photoelectrochemical sensors for detection of ions in water. CHINESE CHEM LETT 2022. [DOI: 10.1016/j.cclet.2022.107904] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
12
|
Rebolledo-Perales L, Ibarra I, Guzman MF, Guerrero GI, Álvarez Romero GA. A novel ion-imprinted polymer based on pyrrole as functional monomer for the voltammetric determination of Hg(II) in water samples. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2022.141258] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
13
|
Xia Y, Zhao Y, Ai F, Yi Y, Liu T, Lin H, Zhu G. N and P co-doped MXenes nanoribbons for electrodeposition-free stripping analysis of Cu(II) and Hg(II). JOURNAL OF HAZARDOUS MATERIALS 2022; 425:127974. [PMID: 34883378 DOI: 10.1016/j.jhazmat.2021.127974] [Citation(s) in RCA: 21] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/16/2021] [Revised: 11/29/2021] [Accepted: 11/30/2021] [Indexed: 06/13/2023]
Abstract
The present electrochemical stripping analysis (ESA) for multiple heavy metal ions (HMI) generally requires an electrodeposition process at a very low potential below -1.0 V, which inevitably makes the sensing procedures more complex, inefficient and power-wasting. Meanwhile, the emerging MXenes rising-star materials have been studied in various fields recently. While there are only few reports focusing on the heteroatom doping of MXenes, especially no doping-MXenes for electroanalysis. Based on these issues, a novel multifunctional heteroatoms-doped MXenes nanomaterial, N and P co-doped Ti3C2Tx MXenes nanoribbons (N,P-Ti3C2TxR), was prepared herein for the first time, and then N,P-Ti3C2TxR was used as electrode material to propose an electrodeposition-free ESA strategy for multiple HMI (Cu2+, Hg2+). Owing to the unique spontaneous adsorption and reducing capacities of N,P-Ti3C2TxR towards Cu2+ and Hg2+ coupled with the excellent sensing performances, Cu2+ and Hg2+ can undergo self-reduction to be preconcentrated on N,P-Ti3C2TxR surface with the form of Cu0 and Hg0, thus a simple and ultrasensitive electrodeposition-free ESA platform was developed successfully for the simultaneous detection of Cu2+and Hg2+. This work opened a new pathway for the detection for multiple HMI and the preparation/application of heteroatoms doping MXenes.
Collapse
Affiliation(s)
- Yixuan Xia
- School of the Environment and Safety Engineering, Collaborative Innovation Center of Technology and Material of Water Treatment, Jiangsu University, Zhenjiang 212013, PR China
| | - Yong Zhao
- Guangzhou Baiyun Airport Customs Comprehensive Technical Service Center, Guangzhou Baiyun Airport Customs District People's Republic of China, Guangzhou 510470, PR China
| | - Fengxiang Ai
- School of the Environment and Safety Engineering, Collaborative Innovation Center of Technology and Material of Water Treatment, Jiangsu University, Zhenjiang 212013, PR China
| | - Yinhui Yi
- School of the Environment and Safety Engineering, Collaborative Innovation Center of Technology and Material of Water Treatment, Jiangsu University, Zhenjiang 212013, PR China
| | - Tingting Liu
- School of the Environment and Safety Engineering, Collaborative Innovation Center of Technology and Material of Water Treatment, Jiangsu University, Zhenjiang 212013, PR China
| | - Huiyu Lin
- Fujian Key Laboratory of Functional Marine Sensing Materials, Ocean College, Minjiang University, PR China
| | - Gangbing Zhu
- School of the Environment and Safety Engineering, Collaborative Innovation Center of Technology and Material of Water Treatment, Jiangsu University, Zhenjiang 212013, PR China; State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin 130022, PR China; Fujian Key Laboratory of Functional Marine Sensing Materials, Ocean College, Minjiang University, PR China.
| |
Collapse
|
14
|
Cho G, Azzouzi S, Zucchi G, Lebental B. Electrical and Electrochemical Sensors Based on Carbon Nanotubes for the Monitoring of Chemicals in Water-A Review. SENSORS (BASEL, SWITZERLAND) 2021; 22:218. [PMID: 35009763 PMCID: PMC8749835 DOI: 10.3390/s22010218] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Revised: 12/14/2021] [Accepted: 12/24/2021] [Indexed: 12/28/2022]
Abstract
Carbon nanotubes (CNTs) combine high electrical conductivity with high surface area and chemical stability, which makes them very promising for chemical sensing. While water quality monitoring has particularly strong societal and environmental impacts, a lot of critical sensing needs remain unmet by commercial technologies. In the present review, we show across 20 water monitoring analytes and 90 references that carbon nanotube-based electrochemical sensors, chemistors and field-effect transistors (chemFET) can meet these needs. A set of 126 additional references provide context and supporting information. After introducing water quality monitoring challenges, the general operation and fabrication principles of CNT water quality sensors are summarized. They are sorted by target analytes (pH, micronutrients and metal ions, nitrogen, hardness, dissolved oxygen, disinfectants, sulfur and miscellaneous) and compared in terms of performances (limit of detection, sensitivity and detection range) and functionalization strategies. For each analyte, the references with best performances are discussed. Overall, the most frequently investigated analytes are H+ (pH) and lead (with 18% of references each), then cadmium (14%) and nitrite (11%). Micronutrients and toxic metals cover 40% of all references. Electrochemical sensors (73%) have been more investigated than chemistors (14%) or FETs (12%). Limits of detection in the ppt range have been reached, for instance Cu(II) detection with a liquid-gated chemFET using SWCNT functionalized with peptide-enhanced polyaniline or Pb(II) detection with stripping voltammetry using MWCNT functionalized with ionic liquid-dithizone based bucky-gel. The large majority of reports address functionalized CNTs (82%) instead of pristine or carboxyl-functionalized CNTs. For analytes where comparison is possible, FET-based and electrochemical transduction yield better performances than chemistors (Cu(II), Hg(II), Ca(II), H2O2); non-functionalized CNTs may yield better performances than functionalized ones (Zn(II), pH and chlorine).
Collapse
Affiliation(s)
- Gookbin Cho
- Laboratoire de Physique des Interfaces et des Couches Minces (LPICM), Centre National de la Recherche Scientifique (CNRS), Ecole Polytechnique, IP Paris, 91128 Palaiseau, France; (G.C.); (S.A.); (G.Z.)
| | - Sawsen Azzouzi
- Laboratoire de Physique des Interfaces et des Couches Minces (LPICM), Centre National de la Recherche Scientifique (CNRS), Ecole Polytechnique, IP Paris, 91128 Palaiseau, France; (G.C.); (S.A.); (G.Z.)
| | - Gaël Zucchi
- Laboratoire de Physique des Interfaces et des Couches Minces (LPICM), Centre National de la Recherche Scientifique (CNRS), Ecole Polytechnique, IP Paris, 91128 Palaiseau, France; (G.C.); (S.A.); (G.Z.)
| | - Bérengère Lebental
- Laboratoire de Physique des Interfaces et des Couches Minces (LPICM), Centre National de la Recherche Scientifique (CNRS), Ecole Polytechnique, IP Paris, 91128 Palaiseau, France; (G.C.); (S.A.); (G.Z.)
- Laboratoire Instrumentation, Simulation et Informatique Scientifique (LISIS), Département Composants et Systèmes (COSYS), Université Gustave Eiffel, 77447 Marne-La-Vallée, France
| |
Collapse
|
15
|
An W, Zhang X, Niu J, Ma Y, Han Z. Unusual hexa-nuclear cadmium cluster functionalized phosphomolybdate as effective photoelectrochemical sensor for trace Cr(VI) detection. CHINESE CHEM LETT 2021. [DOI: 10.1016/j.cclet.2021.12.021] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
|
16
|
Mohamad Nor N, Ramli NH, Poobalan H, Qi Tan K, Abdul Razak K. Recent Advancement in Disposable Electrode Modified with Nanomaterials for Electrochemical Heavy Metal Sensors. Crit Rev Anal Chem 2021; 53:253-288. [PMID: 34565248 DOI: 10.1080/10408347.2021.1950521] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Heavy metal pollution has gained global attention due to its high toxicity and non-biodegradability, even at a low level of exposure. Therefore, the development of a disposable electrode that is sensitive, simple, portable, rapid, and cost-effective as the sensor platform in electrochemical heavy metal detection is vital. Disposable electrodes have been modified with nanomaterials so that excellent electrochemical properties can be obtained. This review highlights the recent progress in the development of numerous types of disposable electrodes modified with nanomaterials for electrochemical heavy metal detection. The disposable electrodes made from carbon-based, glass-based, and paper-based electrodes are reviewed. In particular, the analytical performance, fabrication technique, and integration design of disposable electrodes modified with metal (such as gold, tin and bismuth), carbon (such as carbon nanotube and graphene), and metal oxide (such as iron oxide and zinc oxide) nanomaterials are summarized. In addition, the role of the nanomaterials in improving the electrochemical performance of the modified disposable electrodes is discussed. Finally, the current challenges and future prospect of the disposable electrode modified with nanomaterials are summarized.
Collapse
Affiliation(s)
- Noorhashimah Mohamad Nor
- School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, 14300 Nibong Tebal, Pulau Pinang, Malaysia
| | - Nurul Hidayah Ramli
- School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, 14300 Nibong Tebal, Pulau Pinang, Malaysia
| | - Hemalatha Poobalan
- School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, 14300 Nibong Tebal, Pulau Pinang, Malaysia
| | - Kai Qi Tan
- School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, 14300 Nibong Tebal, Pulau Pinang, Malaysia
| | - Khairunisak Abdul Razak
- School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, 14300 Nibong Tebal, Pulau Pinang, Malaysia.,NanoBiotechnology Research & Innovation (NanoBRI), Institute for Research in Molecular Medicine, Universiti Sains Malaysia, 11800 USM, Pulau Pinang, Malaysia
| |
Collapse
|
17
|
Bao Q, Li G, Yang Z, Pan P, Liu J, Li R, Wei J, Hu W, Cheng W, Lin L. In situ detection of heavy metal ions in sewage with screen-printed electrode-based portable electrochemical sensors. Analyst 2021; 146:5610-5618. [PMID: 34378564 DOI: 10.1039/d1an01012c] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The rapid development of industrial technologies continuously increases the heavy metal pollution of water resources. Recently, portable electrochemical analysis-based devices for detecting heavy metal ions have attracted much attention due to their excellent performance and low fabrication costs. However, it has proven difficult to accommodate complex testing needs in a cost-effective manner. To address these limitations, we propose a new system for the in situ detection of heavy metals in wastewater using an organic light-emitting diode-based panel to display data in real time and Bluetooth to transmit data to a smartphone for rapid analysis. The fabricated device integrates an in situ signal analysis circuit, a Bluetooth chip, a photocured 3D-printed shell, and an electrode sleeve interface. In addition, a fully screen-printed functional electrode plate containing chitosan/PANi-Bi nanoparticle@graphene oxide multi-walled carbon nanotubes is utilized for the rapid detection of heavy metal ions. This device can perform wireless data transmission and analysis and in situ signal acquisition and processing. The sensor exhibits a high sensitivity (Hg2+: 88.34 μA ppm-1 cm-2; Cu2+: 0.956 μA ppm-1 cm-2), low limit of detection (Hg2+: 10 ppb, Cu2+: 0.998 ppm) and high selectivity during the detection of copper and mercury ions in tap water under non-laboratory conditions, and the results of real-time tests reveal that parameters measured in the field and laboratory environments are identical. Hence, this small, portable, electrochemical sensor with a screen-printed electrode can be effectively used for the real-time detection of copper and mercury ions in complex water environments.
Collapse
Affiliation(s)
- Qiwen Bao
- School of Precision Instrument and Optoelectronic Engineering, the State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, 92 Weijin Road, Tianjin 300072, China.
| | - Gang Li
- School of Precision Instrument and Optoelectronic Engineering, the State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, 92 Weijin Road, Tianjin 300072, China.
| | - Zhengchun Yang
- School of Electrical and Electronic Engineering, Tianjin Key Laboratory of Film Electronic & Communication Devices, Advanced Materials and Printed Electronics Center, Tianjin University of Technology, Tianjin 300384, China
| | - Peng Pan
- School of Precision Instrument and Optoelectronic Engineering, the State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, 92 Weijin Road, Tianjin 300072, China.
| | - Jun Liu
- School of Electrical and Electronic Engineering, Tianjin Key Laboratory of Film Electronic & Communication Devices, Advanced Materials and Printed Electronics Center, Tianjin University of Technology, Tianjin 300384, China
| | - Ruirui Li
- School of Electrical and Electronic Engineering, Tianjin Key Laboratory of Film Electronic & Communication Devices, Advanced Materials and Printed Electronics Center, Tianjin University of Technology, Tianjin 300384, China
| | - Jun Wei
- School of Materials Science and Engineering, Harbin Institute of Technology, Shenzhen 518055, China
| | - Wei Hu
- Tianjin Guokeyigong Science and Technology Development Co., Ltd, Tianjin 300399, China
| | - Wenbo Cheng
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences Suzhou, 215163, P. R. China
| | - Ling Lin
- School of Precision Instrument and Optoelectronic Engineering, the State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, 92 Weijin Road, Tianjin 300072, China.
| |
Collapse
|
18
|
Li HK, Ye HL, Zhao XX, Sun XL, Zhu QQ, Han ZY, Yuan R, He H. Artful union of a zirconium-porphyrin MOF/GO composite for fabricating an aptamer-based electrochemical sensor with superb detecting performance. CHINESE CHEM LETT 2021. [DOI: 10.1016/j.cclet.2021.02.042] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
19
|
Wang X, Hu X, Yang W, Wang F, Liu M, Zhu X, Zhang Y, Yao S. Exploitation of a turn-on photoelectrochemical sensing platform based on Au/BiOI for determination of copper(II) ions in food samples. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2021.115536] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
|
20
|
Critical reviews of electro-reactivity of screen-printed nanocomposite electrode to safeguard the environment from trace metals. MONATSHEFTE FUR CHEMIE 2021. [DOI: 10.1007/s00706-021-02802-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
21
|
Bagheri Hariri M, Siavash Moakhar R, Sharifi Abdar P, Zargarnezhad H, Shone M, Rahmani SA, Moradi N, Niksefat V, Shayar Bahadori K, Dolati A. Facile and ultra-sensitive voltammetric electrodetection of Hg 2+ in aqueous media using electrodeposited AuPtNPs/ITO. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:2688-2700. [PMID: 34036981 DOI: 10.1039/d1ay00361e] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
In this study, we have investigated the use of electrodeposited Au-Pt nanoparticles (AuPtNPs) on indium tin oxide (ITO) for the detection of Hg2+ heavy ions in water samples. The mechanism of AuPtNP electrocrystallization on ITO glass in an aqueous solution containing 0.5 mM HAuCl4 + 0.5 mM H2PtCl6 is described for the first time. The nucleation mechanism of monometallic AuNPs on ITO was found to be progressive; however, a transition from progressive to instantaneous was observed for bimetallic AuPtNPs at elevated overpotentials. The modified ITOs were then assessed for the electrodetection of Hg2+ in aqueous media. It was shown by differential pulse voltammetry (DPV) that the sensitivity of the constructed AuPtNPs/ITO electrode toward Hg2+ was about 2.08 μA nM-1. An approximate detection limit of 4.03 nM Hg2+ was achieved, which is below the permissible level of 30.00 nM Hg2+ in drinking water, according to the World Health Organization (WHO). Characterization of AuPt nanostructures was carried out by X-ray diffraction (XRD) patterns, scanning electron microscopy (SEM), and different electrochemical techniques (cyclic voltammetry (CV), chronoamperometry, and electrochemical impedance spectroscopy (EIS)). Our results indicate a good potential of a facile and robust electrochemical assembly for on-site detection of heavy metals in water samples.
Collapse
Affiliation(s)
- Mohiedin Bagheri Hariri
- Institute for Corrosion and Multiphase Technology, Department of Chemical and Biomolecular Engineering, Ohio University, Athens, Ohio 45701, USA.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
22
|
Niu B, Yao B, Zhu M, Guo H, Ying S, Chen Z. Carbon paste electrode modified with fern leave-like MIL-47(as) for electrochemical simultaneous detection of Pb(II), Cu(II) and Hg(II). J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2021.115121] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
23
|
Simple, rapid, and sensitive on-site detection of Hg 2+ in water samples through combining portable evanescent wave optofluidic biosensor and fluorescence resonance energy transfer principle. Anal Chim Acta 2021; 1155:338351. [PMID: 33766323 DOI: 10.1016/j.aca.2021.338351] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2021] [Revised: 02/17/2021] [Accepted: 02/23/2021] [Indexed: 12/28/2022]
Abstract
Rapid and sensitive detection of Hg2+ in the environment and drinking water is vital because of its non-degradability, bioaccumulation, and high toxicity. Herein, we report a portable evanescent wave optofluidic biosensor (EWOB) for simple sensitive detection of Hg2+ using fluorescence labeled poly-A DNA strand (CY-A14) and quencher labeled poly-T DNA strand (BQ-T14) as signal reporter and biorecognition element, respectively. Both CY-A14 and Hg2+ can competitively bind with BQ-T14 based on DNA hybridization and the specifical binding of Hg2+ and T bases of DNA to form T-Hg2+-T mismatch structure, respectively. Higher concentration of Hg2+ lead to less CY-A14 bound to BQ-T14 and thus a higher fluorescence intensity. The influence of several key environmental factors on Hg2+ biosensor, such as pH, temperature, and ionic strength, was investigated in details because they were essential for practical applications of Hg2+ biosensor. Under optimal conditions, a detection cycle for a single sample, including the measurement and regeneration, was less than 10 min with a Hg2+ detection limit of 8.5 nM. The high selectivity of the biosensor was showed by evaluating its response to various potentially interfering metal ions. Our results clearly demonstrated that the portable EWOB could serve as a powerful tool for rapid and sensitive on-site detection of Hg2+ in real water samples. The EWOB is also potentially applicable to detect other heavy metal ions or small molecule targets for which DNA/aptamers could be applied as specific biosensing probes.
Collapse
|