1
|
Zhao R, Zhao W, Huang J, Fang M, Dong Y, Chen J, Ji Z, Tian M. Prevalence and Risk Factors of Peri-Implant Disease: A Retrospective Case-Control Study in Western China. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:12667. [PMID: 36231969 PMCID: PMC9566187 DOI: 10.3390/ijerph191912667] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/05/2022] [Revised: 09/24/2022] [Accepted: 09/30/2022] [Indexed: 06/16/2023]
Abstract
BACKGROUND The present study aimed to investigate the prevalence of peri-implant disease and identify potential disease risk factors in western China. METHODS The present retrospective study was conducted in 131 consecutive patients receiving 248 dental implants treated with implant-supported prostheses with a mean follow-up of 2.52 years. Several patient-related, implant-related, and oral hygiene maintenance factors were analyzed. RESULTS Peri-implant disease developed in 68 (51.91%) patients and 110 (44.35%) implants. The prevalence of peri-implant mucositis and peri-implantitis were 45.80% and 7.63%, respectively, at the subject level, and 36.69% and 7.66%, respectively, at the implant level. Multivariate analysis exhibited that male [odds ratio (OR) = 1.91; 95% confidence interval (CI): 1.02-3.57; p = 0.04], implant length < 10mm (OR = 7.87; 95% CI:1.62-38.46; p = 0.01), poor proximal contact of the prosthesis (OR = 1.90; 95% CI: 1.06-3.42; p = 0.03), tooth brushing once a day (OR = 3.11; 95% CI: 1.26-7.68; p = 0.04) and moderate periodontitis (OR = 13.00; 95% CI: 4.38-38.60; p < 0.01) were independent risk factors for peri-implant disease.
Collapse
Affiliation(s)
- Rui Zhao
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Wen Zhao
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Jin Huang
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Ming Fang
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Yan Dong
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Jihua Chen
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Zhaohua Ji
- Department of Epidemiology, School of Public Health, Air Force Medical University, Xi’an 710032, China
- Ministry of Education Key Lab of Hazard Assessment and Control in Special Operational Environment, Air Force Medical University, Xi’an 710032, China
| | - Min Tian
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| |
Collapse
|
2
|
Zhou H, Ye S, Lyu X, Feng H, Liu M, Wen C. Evaluation of sealing efficacy and removal convenience of sealing materials for implant abutment screw access holes. BMC Oral Health 2022; 22:362. [PMID: 36008833 PMCID: PMC9404578 DOI: 10.1186/s12903-022-02403-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Accepted: 08/22/2022] [Indexed: 11/24/2022] Open
Abstract
Background Sealing materials are used to fill abutment screw access holes (SAH) to prevent microleakage and protect the central screws in oral implant restoration. However, thus far, no consensus has been reached on sealing material selection. In this study, a comparison of the sealing efficacy and removal convenience of different sealing materials for cement-retained implant restoration was conducted. Methods Various sealing materials were classified into five groups, namely, gutta-percha (GP), temporary restorative paste (TRP), vinyl polysiloxane (VPS), polytetrafluoroethylene (PTFE) tape, and onlay resin (OR), and 35 sets of analog-abutments were allocated into five groups of seven specimens. A sealing efficacy test was conducted using a modified dye-penetration method, in which a lower absorbance indicated better sealing efficacy. For the removal-convenience test, the materials were removed from each SAH after solidification, and the retrieval time was recorded. Results On days 1 and 10, PTFE exhibited the highest absorbance value with significant differences compared to the other groups. On day 30, TRP and PTFE showed significantly higher absorbance values than GP, VPS, and OR, but no significant difference was detected between TRP and PTFE (p = 0.424). The absorbance values of TRP and PTFE from days 1, 10, and 30 showed significant intragroup differences, while those of the other groups did not. In terms of the removal convenience on days 1, 10, and 30, VPS achieved the best performance, followed by PTFE, OR, TRP, and GP. Conclusion Within the limitations of this experiment, VPS and OR showed better sealing efficacy against microleakage and a more convenient removal than the other materials; thus, VPS and OR are recommended for clinical use.
Collapse
Affiliation(s)
- Huangjun Zhou
- Department of Oral Implantology, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, Sichuan, China.,Luzhou Key Laboratory of Oral and Maxillofacial Reconstruction and Regeneration, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, Sichuan, China
| | - Sixian Ye
- Department of Oral Implantology, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, Sichuan, China.,Luzhou Key Laboratory of Oral and Maxillofacial Reconstruction and Regeneration, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, Sichuan, China
| | - Xingyu Lyu
- Luzhou Key Laboratory of Oral and Maxillofacial Reconstruction and Regeneration, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, Sichuan, China
| | - Hao Feng
- Luzhou Key Laboratory of Oral and Maxillofacial Reconstruction and Regeneration, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, Sichuan, China.,Department of Oral and Maxillofacial Surgery, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, Sichuan, China
| | - Min Liu
- Luzhou Key Laboratory of Oral and Maxillofacial Reconstruction and Regeneration, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, Sichuan, China.,Department of Prosthodontics, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, Sichuan, China
| | - Cai Wen
- Department of Oral Implantology, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, Sichuan, China. .,Luzhou Key Laboratory of Oral and Maxillofacial Reconstruction and Regeneration, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, Sichuan, China. .,Department of VIP Dental Service, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, Sichuan, China.
| |
Collapse
|
3
|
Sukegawa S, Yoshii K, Hara T, Tanaka F, Yamashita K, Kagaya T, Nakano K, Takabatake K, Kawai H, Nagatsuka H, Furuki Y. Is attention branch network effective in classifying dental implants from panoramic radiograph images by deep learning? PLoS One 2022; 17:e0269016. [PMID: 35895591 PMCID: PMC9328496 DOI: 10.1371/journal.pone.0269016] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2022] [Accepted: 05/13/2022] [Indexed: 11/19/2022] Open
Abstract
Attention mechanism, which is a means of determining which part of the forced data is emphasized, has attracted attention in various fields of deep learning in recent years. The purpose of this study was to evaluate the performance of the attention branch network (ABN) for implant classification using convolutional neural networks (CNNs). The data consisted of 10191 dental implant images from 13 implant brands that cropped the site, including dental implants as pretreatment, from digital panoramic radiographs of patients who underwent surgery at Kagawa Prefectural Central Hospital between 2005 and 2021. ResNet 18, 50, and 152 were evaluated as CNN models that were compared with and without the ABN. We used accuracy, precision, recall, specificity, F1 score, and area under the receiver operating characteristics curve as performance metrics. We also performed statistical and effect size evaluations of the 30-time performance metrics of the simple CNNs and the ABN model. ResNet18 with ABN significantly improved the dental implant classification performance for all the performance metrics. Effect sizes were equivalent to “Huge” for all performance metrics. In contrast, the classification performance of ResNet50 and 152 deteriorated by adding the attention mechanism. ResNet18 showed considerably high compatibility with the ABN model in dental implant classification (AUC = 0.9993) despite the small number of parameters. The limitation of this study is that only ResNet was verified as a CNN; further studies are required for other CNN models.
Collapse
Affiliation(s)
- Shintaro Sukegawa
- Department of Oral and Maxillofacial Surgery, Kagawa Prefectural Central Hospital, Takamatsu, Kagawa, Japan
- Department of Oral Pathology and Medicine, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama, Japan
- * E-mail:
| | - Kazumasa Yoshii
- Department of Intelligence Science and Engineering, Graduate School of Natural Science and Technology, Gifu University, Gifu, Japan
| | - Takeshi Hara
- Department of Electrical, Electronic and Computer Engineering, Faculty of Engineering, Gifu University, Gifu, Gifu, Japan
- Center for Healthcare Information Technology, Tokai National Higher Education and Research System, Gifu, Gifu, Japan
| | - Futa Tanaka
- Department of Electrical, Electronic and Computer Engineering, Faculty of Engineering, Gifu University, Gifu, Gifu, Japan
| | | | - Tutaro Kagaya
- Department of Intelligence Science and Engineering, Graduate School of Natural Science and Technology, Gifu University, Gifu, Japan
| | - Keisuke Nakano
- Department of Oral Pathology and Medicine, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama, Japan
| | - Kiyofumi Takabatake
- Department of Oral Pathology and Medicine, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama, Japan
| | - Hotaka Kawai
- Department of Oral Pathology and Medicine, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama, Japan
| | - Hitoshi Nagatsuka
- Department of Oral Pathology and Medicine, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama, Japan
| | - Yoshihiko Furuki
- Department of Oral and Maxillofacial Surgery, Kagawa Prefectural Central Hospital, Takamatsu, Kagawa, Japan
| |
Collapse
|
4
|
Bai Y, Wang L, Zhao L, Lingling E, Yang S, Jia S, Wen N. Antibacterial and Antioxidant Effects of Magnesium Alloy on Titanium Dental Implants. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2022; 2022:6537676. [PMID: 35035523 PMCID: PMC8758302 DOI: 10.1155/2022/6537676] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/04/2021] [Accepted: 12/07/2021] [Indexed: 11/18/2022]
Abstract
OBJECTIVES In this study, a new type of dental implant by covering the surface of the titanium (Ti) implant with zinc-magnesium (Zn-Mg) alloy was designed, to study the antibacterial and antioxidant effects of Mg alloy on titanium (Ti) implants in oral implant restoration. METHODS Human gingival fibroblasts (HGFs), S. sanguinis, and F. nucleatum bacteria were used to detect the bioactivity and antibacterial properties of Mg alloy-coated Ti implants. In addition, B6/J mice implanted with different materials were used to further detect their antibacterial and antioxidant properties. RESULTS The results showed that Mg alloy could better promote the adhesion and proliferation and improve the alkaline phosphatase (ALP) activity of HGFs, which contributed to better improved stability of implant osseointegration. In addition, Mg alloy could better inhibit the proliferation of S. sanguinis, while no significant difference was found in the proliferation of F. nucleatum between the two implants. In the mouse model, the peripheral inflammatory reaction and oxidative stress of the Mg alloy implant were significantly lower than those of the Ti alloy implant. CONCLUSIONS Zn-Mg alloy-coated Ti implants could better inhibit the growth of Gram-positive bacteria in the oral cavity, inhibit oxidative stress, and facilitate the proliferation activity of HGFs and the potential of osteoblast differentiation, thus, better increasing the stability of implant osseointegration.
Collapse
Affiliation(s)
- Yang Bai
- Department of Stomatology, The First Medical Center, Chinese PLA General Hospital, Beijing 100853, China
| | - Lin Wang
- Department of Stomatology, The First Medical Center, Chinese PLA General Hospital, Beijing 100853, China
| | - Lisheng Zhao
- Department of Stomatology, The First Medical Center, Chinese PLA General Hospital, Beijing 100853, China
| | - E. Lingling
- Department of Stomatology, The First Medical Center, Chinese PLA General Hospital, Beijing 100853, China
| | - Shuo Yang
- Department of Stomatology, The First Medical Center, Chinese PLA General Hospital, Beijing 100853, China
| | - Shunyi Jia
- Department of Stomatology, The First Medical Center, Chinese PLA General Hospital, Beijing 100853, China
| | - Ning Wen
- Department of Stomatology, The First Medical Center, Chinese PLA General Hospital, Beijing 100853, China
| |
Collapse
|
5
|
Choe R, Balhaddad AA, Fisher JP, Melo MAS, Huang HC. Photodynamic Therapy for Biomodulation and Disinfection in Implant Dentistry: Is It Feasible and Effective? Photochem Photobiol 2021; 97:916-929. [PMID: 33876438 DOI: 10.1111/php.13434] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2020] [Revised: 03/11/2021] [Accepted: 04/13/2021] [Indexed: 12/17/2022]
Abstract
Dental implants are the most common rehabilitation and restorative treatment used to replace missing teeth. Biofilms adhere to implant surfaces to trigger implant-associated infection and inflammatory response. Clinically, the biofilm induces a local host response with the infiltration of phagocytic immune cells. The pro-inflammatory surroundings set off osteoclastogenesis, which leads to the septic loosening of the implant. The standard of dental care for implant-associated infection relies on a combination of surgery and antimicrobial therapy. Antimicrobial photodynamic therapy is a noninvasive and photochemistry-based approach capable of reducing bacterial load and modulating inflammatory responses. In this review, we explore the photobiomodulation and disinfection outcomes promoted by photodynamic therapy for implant infections, highlighting the quality of evidence on the most up-to-date studies, and discuss the major challenges on the advance of these therapeutic strategies.
Collapse
Affiliation(s)
- Robert Choe
- Fischell Department of Bioengineering, University of Maryland, College Park, MD, USA.,Center for Engineering Complex Tissues, University of Maryland, College Park, MD, USA
| | - Abdulrahman A Balhaddad
- Dental Biomedical Sciences Ph.D. Program, University of Maryland School of Dentistry, Baltimore, MD, USA.,Department of Restorative Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - John P Fisher
- Fischell Department of Bioengineering, University of Maryland, College Park, MD, USA.,Center for Engineering Complex Tissues, University of Maryland, College Park, MD, USA
| | - Mary Anne S Melo
- Dental Biomedical Sciences Ph.D. Program, University of Maryland School of Dentistry, Baltimore, MD, USA.,Division of Operative Dentistry, Department of General Dentistry, University of Maryland School of Dentistry, Baltimore, MD, USA
| | - Huang-Chiao Huang
- Fischell Department of Bioengineering, University of Maryland, College Park, MD, USA.,Marlene and Stewart Greenebaum Cancer Center, University of Maryland School of Medicine, Baltimore, MD, USA
| |
Collapse
|
6
|
Takahashi T, Nozaki K, Gonda T, Mameno T, Wada M, Ikebe K. Identification of dental implants using deep learning-pilot study. Int J Implant Dent 2020; 6:53. [PMID: 32959154 PMCID: PMC7505912 DOI: 10.1186/s40729-020-00250-6] [Citation(s) in RCA: 45] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2020] [Accepted: 08/20/2020] [Indexed: 11/16/2022] Open
Abstract
Background In some cases, a dentist cannot solve the difficulties a patient has with an implant because the implant system is unknown. Therefore, there is a need for a system for identifying the implant system of a patient from limited data that does not depend on the dentist’s knowledge and experience. The purpose of this study was to identify dental implant systems using a deep learning method. Methods A dataset of 1282 panoramic radiograph images with implants were used for deep learning. An object detection algorithm (Yolov3) was used to identify the six implant systems by three manufactures. To implement the algorithm, TensorFlow and Keras deep-learning libraries were used. After training was complete, the true positive (TP) ratio and average precision (AP) of each implant system as well as the mean AP (mAP), and mean intersection over union (mIoU) were calculated to evaluate the performance of the model. Results The number of each implant system varied from 240 to 1919. The TP ratio and AP of each implant system varied from 0.50 to 0.82 and from 0.51 to 0.85, respectively. The mAP and mIoU of this model were 0.71 and 0.72, respectively. Conclusions The results of this study suggest that implants can be identified from panoramic radiographic images using deep learning-based object detection. This identification system could help dentists as well as patients suffering from implant problems. However, more images of other implant systems will be necessary to increase the learning performance to apply this system in clinical practice.
Collapse
Affiliation(s)
- Toshihito Takahashi
- Department of Prosthodontics, Gerodontology and Oral Rehabilitation, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka, 565-0871, Japan.
| | - Kazunori Nozaki
- Division of Medical Information, Osaka University Dental Hospital, 1-8 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Tomoya Gonda
- Department of Prosthodontics, Gerodontology and Oral Rehabilitation, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Tomoaki Mameno
- Department of Prosthodontics, Gerodontology and Oral Rehabilitation, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Masahiro Wada
- Department of Prosthodontics, Gerodontology and Oral Rehabilitation, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Kazunori Ikebe
- Department of Prosthodontics, Gerodontology and Oral Rehabilitation, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka, 565-0871, Japan
| |
Collapse
|
7
|
Pieralli S, Spies BC, Hromadnik V, Nicic R, Beuer F, Wesemann C. How Accurate Is Oral Implant Installation Using Surgical Guides Printed from a Degradable and Steam-Sterilized Biopolymer? J Clin Med 2020; 9:jcm9082322. [PMID: 32707759 PMCID: PMC7463912 DOI: 10.3390/jcm9082322] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2020] [Revised: 07/17/2020] [Accepted: 07/17/2020] [Indexed: 01/25/2023] Open
Abstract
3D printed surgical guides are used for prosthetically-driven oral implant placement. When manufacturing these guides, information regarding suitable printing techniques and materials as well as the necessity for additional, non-printed stock parts such as metal sleeves is scarce. The aim of the investigation was to determine the accuracy of a surgical workflow for oral implant placement using guides manufactured by means of fused deposition modeling (FDM) from a biodegradable and sterilizable biopolymer filament. Furthermore, the potential benefit of metal sleeve inserts should be assessed. A surgical guide was designed for the installation of two implants in the region of the second premolar (SP) and second molar (SM) in a mandibular typodont model. For two additive manufacturing techniques (stereolithography [SLA]: reference group, FDM: observational group) n = 10 surgical guides, with (S) and without (NS) metal sleeves, were used. This resulted in 4 groups of 10 samples each (SLA-S/NS, FDM-S/NS). Target and real implant positions were superimposed and compared using a dedicated software. Sagittal, transversal, and vertical discrepancies at the level of the implant shoulder, apex and regarding the main axis were determined. MANOVA with posthoc Tukey tests were performed for statistical analyses. Placed implants showed sagittal and transversal discrepancies of <1 mm, vertical discrepancies of <0.6 mm, and axial deviations of ≤3°. In the vertical dimension, no differences between the four groups were measured (p ≤ 0.054). In the sagittal dimension, SLA groups showed decreased deviations in the implant shoulder region compared to FDM (p ≤ 0.033), whereas no differences in the transversal dimension between the groups were measured (p ≤ 0.054). The use of metal sleeves did not affect axial, vertical, and sagittal accuracy, but resulted in increased transversal deviations (p = 0.001). Regarding accuracy, biopolymer-based surgical guides manufactured by means of FDM present similar accuracy than SLA. Cytotoxicity tests are necessary to confirm their biocompatibility in the oral environment.
Collapse
Affiliation(s)
- Stefano Pieralli
- Department of Prosthetic Dentistry, Center for Dental Medicine, Medical Center—University of Freiburg, Faculty of Medicine—University of Freiburg, 79106 Freiburg, Germany;
| | - Benedikt Christopher Spies
- Department of Prosthetic Dentistry, Center for Dental Medicine, Medical Center—University of Freiburg, Faculty of Medicine—University of Freiburg, 79106 Freiburg, Germany;
- Correspondence: ; Tel.: +49-761-270-49060
| | - Valentin Hromadnik
- Department of Prosthodontics, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Charité—Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Geriatric Dentistry and Craniomandibular Disorders, 14197 Berlin, Germany; (V.H.); (R.N.); (F.B.); (C.W.)
| | - Robert Nicic
- Department of Prosthodontics, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Charité—Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Geriatric Dentistry and Craniomandibular Disorders, 14197 Berlin, Germany; (V.H.); (R.N.); (F.B.); (C.W.)
| | - Florian Beuer
- Department of Prosthodontics, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Charité—Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Geriatric Dentistry and Craniomandibular Disorders, 14197 Berlin, Germany; (V.H.); (R.N.); (F.B.); (C.W.)
| | - Christian Wesemann
- Department of Prosthodontics, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Charité—Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Geriatric Dentistry and Craniomandibular Disorders, 14197 Berlin, Germany; (V.H.); (R.N.); (F.B.); (C.W.)
- Department of Orthodontics, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Charité—Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Dentofacial Orthopedics and Pedodontics, Aßmannshauser Str. 4-6, 14197 Berlin, Germany
| |
Collapse
|
8
|
Kim JJ, Lee JH, Kim JC, Lee JB, Yeo ISL. Biological Responses to the Transitional Area of Dental Implants: Material- and Structure-Dependent Responses of Peri-Implant Tissue to Abutments. MATERIALS 2019; 13:ma13010072. [PMID: 31877848 PMCID: PMC6981768 DOI: 10.3390/ma13010072] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/21/2019] [Revised: 12/16/2019] [Accepted: 12/18/2019] [Indexed: 12/12/2022]
Abstract
The stability of peri-implant tissue is essential for the long-term success of dental implants. Although various types of implant connections are used, little is known about the effects of the physical mechanisms of dental implants on the stability of peri-implant tissue. This review summarizes the relevant literature to establish guidelines regarding the effects of connection type between abutments and implants in soft and hard tissues. Soft tissue seals can affect soft tissue around implants. In external connections, micromobility between the abutment and the hex component of the implant, resulting from machining tolerance, can destroy the soft tissue seal, potentially leading to microbial invasion. Internal friction connection implants induce strain on the surrounding bone via implant wall expansion that translates into masticatory force. This strain is advantageous because it increases the amount and quality of peri-implant bone. The comparison of internal and external connections, the two most commonly used connection types, reveals that internal friction has a positive influence on both soft and hard tissues.
Collapse
Affiliation(s)
- Jung-Ju Kim
- Department of Periodontology, Seoul National University School of Dentistry, Seoul 03080, Korea; (J.-J.K.); (J.C.K.); (J.-B.L.)
| | - Jae-Hyun Lee
- Department of Prosthodontics, One-Stop Specialty Center, Seoul National University Dental Hospital, Seoul 03080, Korea;
| | - Jeong Chan Kim
- Department of Periodontology, Seoul National University School of Dentistry, Seoul 03080, Korea; (J.-J.K.); (J.C.K.); (J.-B.L.)
| | - Jun-Beom Lee
- Department of Periodontology, Seoul National University School of Dentistry, Seoul 03080, Korea; (J.-J.K.); (J.C.K.); (J.-B.L.)
| | - In-Sung Luke Yeo
- Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, Seoul 03080, Korea
- Correspondence: ; Tel.: +82-2-2072-2661
| |
Collapse
|