1
|
Qi X, Gao X, Wang X, Xu P. Harnessing Pseudomonas putida in bioelectrochemical systems. Trends Biotechnol 2024; 42:877-894. [PMID: 38184440 DOI: 10.1016/j.tibtech.2023.12.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2023] [Revised: 12/02/2023] [Accepted: 12/04/2023] [Indexed: 01/08/2024]
Abstract
Bioelectrochemical systems (BESs), a group of promising integrated systems that combine the advantages of biotechnology and electrochemical techniques, offer new opportunities to address environmental and energy challenges. Exoelectrogens capable of extracellular electron transfer (EET) are the critical factor enabling electrocatalytic activity in BESs. Pseudomonas putida, an aerobe widely used in environmental bioremediation, the biosynthesis of valuable chemicals, and energy bioproduction, has attracted much attention due to its unique application potential in BESs. This review provides a comprehensive understanding of the working principles, key factors, and applications of BESs using P. putida as the exoelectrogen. The challenges and perspectives for the development of BESs with P. putida as the exoelectrogen are also proposed and discussed.
Collapse
Affiliation(s)
- Xiaoyan Qi
- State Key Laboratory of Microbial Technology, Shandong University, Qingdao 266237, PR China
| | - Xinyu Gao
- College of Arts and Science, University of North Carolina at Chapel Hill, Chapel Hill, NC 27514, USA
| | - Xia Wang
- State Key Laboratory of Microbial Technology, Shandong University, Qingdao 266237, PR China.
| | - Ping Xu
- State Key Laboratory of Microbial Metabolism and School of Life Sciences and Biotechnology, Shanghai Jiao Tong University, Shanghai 200240, PR China.
| |
Collapse
|
2
|
Yuan J, Zhao K, Tan X, Xue R, Zeng Y, Ratti C, Trivedi P. Perspective on the development of synthetic microbial community (SynCom) biosensors. Trends Biotechnol 2023; 41:1227-1236. [PMID: 37183053 DOI: 10.1016/j.tibtech.2023.04.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Revised: 04/10/2023] [Accepted: 04/20/2023] [Indexed: 05/16/2023]
Abstract
Synthetic microbial community (SynCom) biosensors are a promising technology for detecting and responding to environmental cues and target molecules. SynCom biosensors use engineered microorganisms to create a more complex and diverse sensing system, enabling them to respond to stimuli with enhanced sensitivity and accuracy. Here, we give a definition of SynCom biosensors, outline their construction workflow, and discuss current biosensing technology. We also highlight the challenges and future for developing and optimizing SynCom biosensors and the potential applications in agriculture and food management, biotherapeutic development, home sensing, urban and environmental monitoring, and the One Health foundation. We believe SynCom biosensors could be used in a real-time and remote-controlled manner to sense the chaos of constantly dynamic environments.
Collapse
Affiliation(s)
- Jing Yuan
- Microbiome Network and Department of Agricultural Biology, Colorado State University, Fort Collins, CO 80524, USA; Senseable City Lab, Department of Urban Studies and Planning, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
| | - Kankan Zhao
- Institute of Soil and Water Resources and Environmental Science, College of Environmental and Resource Sciences, Zhejiang University, Hangzhou 310058, China
| | - Xiangfeng Tan
- Institute of Digital Agriculture, Zhejiang Academy of Agricultural Sciences, Hangzhou, Zhejiang, 310021, China
| | - Ran Xue
- Hangzhou Innovation Center, Zhejiang University, Hangzhou 311200, China
| | - Yuan Zeng
- School of Plant and Environmental Sciences, Virginia Tech, Blacksburg, VA 24061, USA; Southern Piedmont Agricultural Research and Extension Center, Virginia Tech, Blackstone, VA 23824, USA
| | - Carlo Ratti
- Senseable City Lab, Department of Urban Studies and Planning, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Pankaj Trivedi
- Microbiome Network and Department of Agricultural Biology, Colorado State University, Fort Collins, CO 80524, USA
| |
Collapse
|
3
|
Chauhan S, Dahiya D, Sharma V, Khan N, Chaurasia D, Nadda AK, Varjani S, Pandey A, Bhargava PC. Advances from conventional to real time detection of heavy metal(loid)s for water monitoring: An overview of biosensing applications. CHEMOSPHERE 2022; 307:136124. [PMID: 35995194 DOI: 10.1016/j.chemosphere.2022.136124] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/08/2022] [Revised: 08/02/2022] [Accepted: 08/16/2022] [Indexed: 06/15/2023]
Abstract
The rapid growth of the industrial sector has expedited the accumulation of heavy metal(loid)s in the environment at hazardous levels. The elements such as arsenic, lead, mercury, cadmium and chromium are lethal in terms of toxicity with severe health impacts. With issues like water scarcity, limitations in wastewater treatment, and costs pertaining to detection in environmental matrices; their rapid and selective detection for reuse of effluents is of the utmost priority. Biosensors are the futuristic tool for the accurate qualitative and quantitative analysis of a specific analyte and integrate biotechnology, microelectronics and nanotechnology to fabricate a miniaturized device without compromising the sensitivity, specificity and accuracy. The characteristic features of supporting matrix largely affect the biosensing ability of the device and incorporation of highly sensitive and durable metal organic frameworks (MOFs) are reported to enhance the efficiency of advanced biosensors. Electrochemical biosensors are among the most widely developed biosensors for the detection of heavy metal(loids), while direct electron transfer approach from the recognition element to the electrode has been found to decrease the chances of interference. This review provides an insight into the recent progress in biosensor technologies for the detection of prevalent heavy metal(loid)s; using advanced support systems such as functional metal-based nanomaterials, carbon nanotubes, quantum dots, screen printed electrodes, glass beads etc. The review also delves critically in comparison of various techno-economic studies and the latest advances in biosensor technology.
Collapse
Affiliation(s)
- Shraddha Chauhan
- Aquatic Toxicology Laboratory, Environmental Toxicology Group, CSIR-Indian Institute of Toxicology Research, Vishvigyan Bhawan, 31, Mahatma Gandhi Marg, Lucknow, Uttar Pradesh, 226 001, India
| | - Digvijay Dahiya
- Department of Biotechnology, National Institute of Technology, Andhra Pradesh Tadepalligudem, 534101, India
| | - Vikas Sharma
- Aquatic Toxicology Laboratory, Environmental Toxicology Group, CSIR-Indian Institute of Toxicology Research, Vishvigyan Bhawan, 31, Mahatma Gandhi Marg, Lucknow, Uttar Pradesh, 226 001, India
| | - Nawaz Khan
- Aquatic Toxicology Laboratory, Environmental Toxicology Group, CSIR-Indian Institute of Toxicology Research, Vishvigyan Bhawan, 31, Mahatma Gandhi Marg, Lucknow, Uttar Pradesh, 226 001, India
| | - Deepshi Chaurasia
- Aquatic Toxicology Laboratory, Environmental Toxicology Group, CSIR-Indian Institute of Toxicology Research, Vishvigyan Bhawan, 31, Mahatma Gandhi Marg, Lucknow, Uttar Pradesh, 226 001, India
| | - Ashok Kumar Nadda
- Department of Biotechnology and Bioinformatics, Jaypee University of Information Technology, Waknaghat, Solan, 173 234, India
| | | | - Ashok Pandey
- Centre for Innovation and Translational Research, CSIR-Indian Institute of Toxicology Research (CSIR-IITR), Vishvigyan Bhawan, 31, Mahatma Gandhi Marg, Lucknow, Uttar Pradesh, 226001, India; Centre for Energy and Environmental Sustainability, Lucknow, Uttar Pradesh, 226029, India; Sustainability Cluster, School of Engineering, University of Petroleum and Energy Studies, Dehradun, 248007, Uttarakhand, India
| | - Preeti Chaturvedi Bhargava
- Aquatic Toxicology Laboratory, Environmental Toxicology Group, CSIR-Indian Institute of Toxicology Research, Vishvigyan Bhawan, 31, Mahatma Gandhi Marg, Lucknow, Uttar Pradesh, 226 001, India.
| |
Collapse
|
4
|
Accelerated antibiotic susceptibility testing of pseudomonas aeruginosa by monitoring extracellular electron transfer on a 3-D paper-based cell culture platform. Biosens Bioelectron 2022; 216:114604. [DOI: 10.1016/j.bios.2022.114604] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Revised: 07/21/2022] [Accepted: 07/26/2022] [Indexed: 11/18/2022]
|
5
|
Chu N, Cai J, Li Z, Gao Y, Liang Q, Hao W, Liu P, Jiang Y, Zeng RJ. Indicators of water biotoxicity obtained from turn-off microbial electrochemical sensors. CHEMOSPHERE 2022; 286:131725. [PMID: 34352539 DOI: 10.1016/j.chemosphere.2021.131725] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/27/2021] [Revised: 07/15/2021] [Accepted: 07/28/2021] [Indexed: 06/13/2023]
Abstract
The development of biosensors is critical to reducing potential risks associated with contamination accidents. However, the application of microbial electrochemical sensors for water biotoxicity monitoring is hampered by the lack of an indicator with high response magnitudes. In this study, microbial electrochemical sensors were fabricated with interdigitated electrode arrays (IDAs), and indicators from various electrochemical analyses were comprehensively investigated. Only the peak of cyclic voltammetry (CV) was highly linearly correlated with the commonly used current indicator during the enrichment of the electroactive biofilm. The resistance fitted from the electrochemical impedance spectroscopy (EIS) data provided a comparable and even higher inhibition ratio (IR) than the current during toxicity assessments. The differential pulse voltammetry (DPV) did not exhibit a higher sensitivity than the CV peak. However, no clear response was observed in the real-time impedance analysis for use in water biotoxicity monitoring. Most of the microbes were in the propidium iodide (PI)-permeable state after the toxicity assessments, although the current was fully recovered. This study demonstrates the potential to use EIS data as indicators of water biotoxicity using microbial electrochemical sensors.
Collapse
Affiliation(s)
- Na Chu
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian, 350002, China
| | - Jiayi Cai
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian, 350002, China
| | - Zhigang Li
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian, 350002, China
| | - Yu Gao
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian, 350002, China
| | - Qinjun Liang
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian, 350002, China
| | - Wen Hao
- State Key Joint Laboratory of Environment Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing, 100084, China
| | - Panpan Liu
- School of Ecology and Environment, Zhengzhou University, Zhengzhou, Henan, 450001, China
| | - Yong Jiang
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian, 350002, China.
| | - Raymond Jianxiong Zeng
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian, 350002, China
| |
Collapse
|
6
|
Chung TH, Dhar BR. Paper-based platforms for microbial electrochemical cell-based biosensors: A review. Biosens Bioelectron 2021; 192:113485. [PMID: 34274625 DOI: 10.1016/j.bios.2021.113485] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2021] [Revised: 06/30/2021] [Accepted: 07/02/2021] [Indexed: 12/13/2022]
Abstract
The development of low-cost analytical devices for on-site water quality monitoring is a critical need, especially for developing countries and remote communities in developed countries with limited resources. Microbial electrochemical cell-based (MXC) biosensors have been quite promising for quantitative and semi-quantitative (often qualitative) measurements of various water quality parameters due to their low cost and simplicity compared to traditional analytical methods. However, conventional MXC biosensors often encounter challenges, such as the slow establishment of biofilms, low sensitivity, and poor recoverability, making them unable to be applied for practical cases. In response, MXC biosensors assembled with paper-based materials demonstrated tremendous potentials to enhance sensitivity and field applicability. Furthermore, the paper-based platforms offer many prominent features, including autonomous liquid transport, rapid bacterial adhesion, lowered resistance, low fabrication cost (<$1 in USD), and eco-friendliness. Therefore, this review aims to summarize the current trend and applications of paper-based MXC biosensors, along with critical discussions on their field applicability. Moreover, future advancements of paper-based MXC biosensors, such as developing a novel paper-based biobatteries, increasing the system performance using an unique biocatalyst, such as yeast, and integrating the biosensor system with other advanced tools, such as machine learning and 3D printing, are highlighted.
Collapse
Affiliation(s)
- Tae Hyun Chung
- Department of Civil and Environmental Engineering, University of Alberta, 9211-116 Street NW, Edmonton, AB, T6G 1H9, Canada
| | - Bipro Ranjan Dhar
- Department of Civil and Environmental Engineering, University of Alberta, 9211-116 Street NW, Edmonton, AB, T6G 1H9, Canada.
| |
Collapse
|
7
|
Olias LG, Di Lorenzo M. Microbial fuel cells for in-field water quality monitoring. RSC Adv 2021; 11:16307-16317. [PMID: 35479166 PMCID: PMC9031575 DOI: 10.1039/d1ra01138c] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2021] [Accepted: 04/23/2021] [Indexed: 12/13/2022] Open
Abstract
The need for water security pushes for the development of sensing technologies that allow online and real-time assessments and are capable of autonomous and stable long-term operation in the field. In this context, Microbial Fuel Cell (MFC) based biosensors have shown great potential due to cost-effectiveness, simplicity of operation, robustness and the possibility of self-powered applications. This review focuses on the progress of the technology in real scenarios and in-field applications and discusses the technological bottlenecks that must be overcome for its success. An overview of the most relevant findings and challenges of MFC sensors for practical implementation is provided. First, performance indicators for in-field applications, which may diverge from lab-based only studies, are defined. Progress on MFC designs for off-grid monitoring of water quality is then presented with a focus on solutions that enhance robustness and long-term stability. Finally, calibration methods and detection algorithms for applications in real scenarios are discussed.
Collapse
Affiliation(s)
- Lola Gonzalez Olias
- Centre for Biosensors, Bioelectronics and Biodevices (C3Bio) and Department of Chemical Engineering, University of Bath Bath BA2 7AY UK
- Water Innovation Research Centre (WIRC), University of Bath Bath BA2 7AY UK
| | - Mirella Di Lorenzo
- Centre for Biosensors, Bioelectronics and Biodevices (C3Bio) and Department of Chemical Engineering, University of Bath Bath BA2 7AY UK
| |
Collapse
|
8
|
Chu N, Liang Q, Hao W, Jiang Y, Zeng RJ. Micro-microbial electrochemical sensor equipped with combined bioanode and biocathode for water biotoxicity monitoring. BIORESOURCE TECHNOLOGY 2021; 326:124743. [PMID: 33503515 DOI: 10.1016/j.biortech.2021.124743] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/09/2020] [Revised: 01/12/2021] [Accepted: 01/15/2021] [Indexed: 06/12/2023]
Abstract
The development of low-cost biosensors for water monitoring is expected to reduce potential risks from contamination accidents. This study reported a novel micro-microbial electrochemical sensor using combined bioanode and biocathode as the sensing element, characterized by a sequential flowing membrane-free channel and a bilateral passive oxygen supply. A decrease in the ratio of number of bioanode to biocathode resulted in a lower power generation, whereas, achieving a similar or even higher toxic response. The voltage was affected by both the flow rate and the acetate concentration. With the increased acetate concentration, a clear trade-off was observed between the electroactivity stimulation of bioanode vs. the electroactivity maintenance of biocathode. Biosensors made good response to the injection of formaldehyde (10 µL of 0.25%, and 100 µL of 0.025%) into the inlet. A high microbial diversity was observed. This work can lead to a revolutionizing way of water monitoring using self-powered micro-biosensors.
Collapse
Affiliation(s)
- Na Chu
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian 350002, China
| | - Qinjun Liang
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian 350002, China
| | - Wen Hao
- State Key Joint Laboratory of Environment Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing 100084, China
| | - Yong Jiang
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian 350002, China.
| | - Raymond Jianxiong Zeng
- Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, Fujian 350002, China
| |
Collapse
|