1
|
Dong X, Wang R, Zhou X, Li P, Yang H. Current mass spectrometry approaches and challenges for the bioanalysis of traditional Chinese medicines. J Chromatogr B Analyt Technol Biomed Life Sci 2016; 1026:15-26. [DOI: 10.1016/j.jchromb.2015.11.048] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2015] [Revised: 11/23/2015] [Accepted: 11/25/2015] [Indexed: 12/11/2022]
|
2
|
Abstract
Microemulsion electrokinetic chromatography (MEEKC) is a special mode of capillary electrophoresis employing a microemulsion as carrier electrolyte. Analytes may partition between the aqueous phase of the microemulsion and its oil droplets which act as a pseudostationary phase. The technique is well suited for the separation of neutral species, in which case charged oil droplets (obtained by addition of an anionic or cationic surfactant) are present. A single set of separation parameters may be sufficient for separation of a wide range of analytes belonging to quite different chemical classes. Fine-tuning of resolution and analysis time may be achieved by addition of organic solvents, by changes in the nature of the surfactants (and cosurfactants) used to stabilize the microemulsion, or by various additives that may undergo some additional interactions with the analytes. Besides the separation of neutral analytes (which may be the most important application area of MEEKC), it can also be employed for cationic and/or anionic species. In this chapter, MEEKC conditions are summarized that have proven their reliability for routine analysis. Furthermore, the mechanisms encountered in MEEKC allow an efficient on-capillary preconcentration of analytes, so that the problem of poor concentration sensitivity of ultraviolet absorbance detection is circumvented.
Collapse
Affiliation(s)
- Wolfgang Buchberger
- Institut für Analytische Chemie, Universität Linz, TNF-Tower, T 209, Altenbergerstraße 69, Linz, 4040, Austria.
| |
Collapse
|
3
|
Abstract
This chapter includes the aspects of carbamazepine. The drug is synthesized by the use of 5H-dibenz[b,f]azepine and phosgene followed by subsequent reaction with ammonia. Carbamazepine is generally used for the treatment of seizure disorders and neuropathic pain, it is also important as off-label for a second-line treatment for bipolar disorder and in combination with an antipsychotic in some cases of schizophrenia when treatment with a conventional antipsychotic alone has failed. Other uses may include attention deficit hyperactivity disorder, schizophrenia, phantom limb syndrome, complex regional pain syndrome, borderline personality disorder, and posttraumatic stress disorder. The chapter discusses the drug metabolism and pharmacokinetics and presents various methods of analysis of this drug such electrochemical analysis, spectroscopic analysis, and chromatographic techniques of separation. It also discusses its physical properties such as solubility characteristics, X-ray powder diffraction pattern, and thermal methods of analysis. The chapter is concluded with a discussion on its biological properties such as activity, toxicity, and safety.
Collapse
|
4
|
Yang H, Ding Y, Cao J, Li P. Twenty-one years of microemulsion electrokinetic chromatography (1991-2012): A powerful analytical tool. Electrophoresis 2013; 34:1273-94. [DOI: 10.1002/elps.201200494] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2012] [Revised: 12/18/2012] [Accepted: 01/22/2013] [Indexed: 12/18/2022]
Affiliation(s)
- Hua Yang
- State Key Laboratory of Natural Medicines (China Pharmaceutical University); Nanjing; P. R. China
| | - Yao Ding
- State Key Laboratory of Natural Medicines (China Pharmaceutical University); Nanjing; P. R. China
| | - Jun Cao
- College of Material Chemistry and Chemical Engineering; Hangzhou Normal University; Hangzhou; P. R. China
| | - Ping Li
- State Key Laboratory of Natural Medicines (China Pharmaceutical University); Nanjing; P. R. China
| |
Collapse
|
5
|
Yu L, Chu K, Ye H, Liu X, Yu L, Xu X, Chen G. Recent advances in microemulsion electrokinetic chromatography. Trends Analyt Chem 2012. [DOI: 10.1016/j.trac.2011.11.003] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
6
|
Breadmore MC. Capillary and microchip electrophoresis: Challenging the common conceptions. J Chromatogr A 2012; 1221:42-55. [DOI: 10.1016/j.chroma.2011.09.062] [Citation(s) in RCA: 83] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2011] [Revised: 09/21/2011] [Accepted: 09/23/2011] [Indexed: 10/17/2022]
|
7
|
Hommerson P, Khan AM, de Jong GJ, Somsen GW. Ionization techniques in capillary electrophoresis-mass spectrometry: principles, design, and application. MASS SPECTROMETRY REVIEWS 2011; 30:1096-1120. [PMID: 21462232 DOI: 10.1002/mas.20313] [Citation(s) in RCA: 58] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2009] [Accepted: 06/03/2010] [Indexed: 05/30/2023]
Abstract
A major step forward in the development and application of capillary electrophoresis (CE) was its coupling to ESI-MS, first reported in 1987. More than two decades later, ESI has remained the principal ionization technique in CE-MS, but a number of other ionization techniques have also been implemented. In this review the state-of-the-art in the employment of soft ionization techniques for CE-MS is presented. First the fundamentals and general challenges of hyphenating conventional CE and microchip electrophoresis with MS are outlined. After elaborating on the characteristics and role of ESI, emphasis is put on alternative ionization techniques including sonic spray ionization (SSI), thermospray ionization (TSI), atmospheric pressure chemical ionization (APCI), atmospheric pressure photoionization (APPI), matrix-assisted laser desorption ionization (MALDI) and continuous-flow fast atom bombardment (CF-FAB). The principle of each ionization technique is outlined and the experimental set-ups of the CE-MS couplings are described. The strengths and limitations of each ionization technique with respect to CE-MS are discussed and the applicability of the various systems is illustrated by a number of typical examples.
Collapse
MESH Headings
- Electrophoresis, Capillary/instrumentation
- Electrophoresis, Capillary/methods
- Equipment Design/instrumentation
- Equipment Design/methods
- Pharmaceutical Preparations/analysis
- Pharmaceutical Preparations/chemistry
- Proteins/analysis
- Proteins/chemistry
- Spectrometry, Mass, Electrospray Ionization/instrumentation
- Spectrometry, Mass, Electrospray Ionization/methods
- Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/instrumentation
- Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods
Collapse
Affiliation(s)
- Paul Hommerson
- Department of Biomedical Analysis, Utrecht University, PO Box 80082, 3508 TB Utrecht, The Netherlands.
| | | | | | | |
Collapse
|
8
|
Ryan R, McEvoy E, Sheila Donegan, Power J, Altria K. Recent developments in the methodology and application of MEEKC. Electrophoresis 2010; 32:184-201. [DOI: 10.1002/elps.201000372] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2010] [Revised: 08/28/2010] [Accepted: 09/21/2010] [Indexed: 02/05/2023]
|
9
|
Aurora-Prado MS, Silva CA, Tavares MFM, Altria KD. Rapid Determination of Water-Soluble and Fat-Soluble Vitamins in Commercial Formulations by MEEKC. Chromatographia 2010. [DOI: 10.1365/s10337-010-1704-9] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
10
|
Somsen GW, Mol R, de Jong GJ. On-line coupling of electrokinetic chromatography and mass spectrometry. J Chromatogr A 2010; 1217:3978-91. [DOI: 10.1016/j.chroma.2010.01.026] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2009] [Revised: 12/23/2009] [Accepted: 01/08/2010] [Indexed: 11/27/2022]
|
11
|
Ehrenhauser FS, Wornat MJ, Valsaraj KT, Rodriguez P. Design and evaluation of a dopant-delivery system for an orthogonal atmospheric-pressure photoionization source and its performance in the analysis of polycyclic aromatic hydrocarbons. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2010; 24:1351-1357. [PMID: 20391608 DOI: 10.1002/rcm.4518] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
Atmospheric-pressure photoionization (APPI) mass spectrometry benefits from the addition of an ionization-enhancing dopant such as benzene. A passive dopant-delivery system has therefore been designed for use with the orthogonal APPI source within a commercial liquid chromatographic instrument with mass spectrometric detector. By providing the dopant in the gas phase, the newly designed equipment avoids mixing problems and other difficulties associated with liquid dopant addition. The system is a simple and durable design that can reliably deliver virtually any dopant with sufficient vapor pressure in the temperature range of 20 to 120 degrees C. At the optimum dopant flow rate (10% of the mobile phase flow rate) for high-performance liquid chromatography with narrow-bore (2.1 mm) columns, the system allows for uninterrupted routine analysis for up to two weeks. The performance of the device has been evaluated with benzene as dopant and with a test mixture consisting of four polycyclic aromatic hydrocarbons (PAH): naphthalene, 9H-fluorene, anthracene, and phenanthrene. All four PAH can be detected with an excellent signal-to-noise ratio in the scanning mode and a limit of detection down to 0.42 ng on column (51 pg in single-ion monitoring mode). The concentration calibration curves are linear over a range of three orders of magnitude, with correlation coefficients greater than 0.99. The utilization of benzene as dopant not only increases the sensitivity significantly - 20-fold, compared with dopant-free operation - but the low m/z values of the background ions observed also allow for the effective quantitative and qualitative analysis of PAH.
Collapse
Affiliation(s)
- Franz S Ehrenhauser
- Cain Department of Chemical Engineering, Louisiana State University, Baton Rouge, LA 70803, USA
| | | | | | | |
Collapse
|
12
|
Bytzek AK, Reithofer MR, Galanski M, Groessl M, Keppler BK, Hartinger CG. The first example of MEEKC-ICP-MS coupling and its application for the analysis of anticancer platinum complexes. Electrophoresis 2010; 31:1144-1150. [PMID: 20349510 PMCID: PMC3512080 DOI: 10.1002/elps.200900522] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
MEEKC is a powerful electrodriven separation technique with many applications in different disciplines, including medicinal chemistry; however, up to now the coupling to highly sensitive and selective MS detectors was limited due to the ion suppressive effect of the commonly used surfactant SDS. Herein, the first example of the coupling of MEEKC to ICP-MS is presented and an MEEKC method for the separation of Pt(II) and Pt(IV) anticancer drugs and drug candidates was developed. Different compositions of microemulsions were evaluated and the data were compared with those collected with standard ultraviolet/visible (UV/vis) spectroscopy detection. The MEEKC-ICP-MS system was found to be more sensitive than MEEKC-UV/vis and the analysis of UV/vis silent compounds is now achievable. The migration behavior of the Pt(II) and Pt(IV) compounds under investigation is correlated to their different chemical structures.
Collapse
Affiliation(s)
- Anna K. Bytzek
- Institute of Inorganic Chemistry, University of Vienna, Waehringer Str. 42, A-1090 Vienna, Austria
| | - Michael R. Reithofer
- Institute of Inorganic Chemistry, University of Vienna, Waehringer Str. 42, A-1090 Vienna, Austria
| | - Markus Galanski
- Institute of Inorganic Chemistry, University of Vienna, Waehringer Str. 42, A-1090 Vienna, Austria
| | - Michael Groessl
- Institute of Inorganic Chemistry, University of Vienna, Waehringer Str. 42, A-1090 Vienna, Austria
| | - Bernhard K. Keppler
- Institute of Inorganic Chemistry, University of Vienna, Waehringer Str. 42, A-1090 Vienna, Austria
| | - Christian G. Hartinger
- Institute of Inorganic Chemistry, University of Vienna, Waehringer Str. 42, A-1090 Vienna, Austria
| |
Collapse
|
13
|
Henchoz Y, Romand S, Schappler J, Rudaz S, Veuthey JL, Carrupt PA. High-throughput log P determination by MEEKC coupled with UV and MS detections. Electrophoresis 2010; 31:952-64. [DOI: 10.1002/elps.200900540] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
14
|
Ryan R, Donegan S, Power J, Altria K. Advances in the theory and application of MEEKC. Electrophoresis 2010; 31:755-67. [DOI: 10.1002/elps.200900568] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
15
|
Ryan R, Donegan S, Power J, McEvoy E, Altria K. Recent advances in the methodology, optimisation and application of MEEKC. Electrophoresis 2009; 30:65-82. [PMID: 19107700 DOI: 10.1002/elps.200800439] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
MEEKC is an electrodriven separation technique. Oil-in-water microemulsions (MEs) and to a lesser extent water-in-oil MEs have been used in MEEKC as BGEs to achieve separation of a diverse range of solutes. The more common (oil-in-water) MEs are composed of nanometre-sized droplets of oil suspended in an aqueous buffer. Interfacial tension between the oil and aqueous phase is reduced close to zero by the presence of a surfactant and a co-surfactant. MEEKC is capable of providing fast and efficient separations for a wide range of acidic, basic and neutral, water-soluble and -insoluble compounds. This review details the advances in MEEKC-based separations from the period 2006 to 2008. Areas covered include online sample concentration, chiral separation, suppressed electroosmosis MEEKC, MEEKC-MS, and the use of MEEKC in predicting migration behaviour and solute characteristics. A fundamental introduction to MEEKC, along with the presentation and discussion of recent applications is also included.
Collapse
Affiliation(s)
- Richie Ryan
- Waterford Institute of Technology, Cork Road Campus, Waterford, Ireland.
| | | | | | | | | |
Collapse
|
16
|
Klampfl CW. CE with MS detection: A rapidly developing hyphenated technique. Electrophoresis 2009; 30 Suppl 1:S83-91. [DOI: 10.1002/elps.200900088] [Citation(s) in RCA: 84] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
17
|
He J, Shamsi SA. Multivariate approach for the enantioselective analysis in micellar electrokinetic chromatography-mass spectrometry. I. Simultaneous optimization of binaphthyl derivatives in negative ion mode. J Chromatogr A 2009; 1216:845-56. [PMID: 19110258 PMCID: PMC2861921 DOI: 10.1016/j.chroma.2008.11.093] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2008] [Revised: 11/10/2008] [Accepted: 11/13/2008] [Indexed: 11/30/2022]
Abstract
A mixture of two molecular micelles polysodium N-undecenoxy carbonyl-L-leucinate, (poly-L-SUCL) and polysodium N-undecanoyl leucylvalinate, (poly-L-SULV) was utilized in micellar electrokinetic chromatography-electrospray ionization-mass spectrometry (MEKC-ESI-MS) to simultaneously separate and detect enantiomers of binaphthyl derivatives. Separation parameters such as background buffer composition, voltage, temperature, and nebulizer pressure were optimized using a multivariate central composite design (CCD). Baseline enantioseparation for both analytes was achieved. The CCD was also used in the optimization of sheath liquid and spray chamber parameters to achieve optimum ESI-MS response. The results demonstrate that CCD is a powerful tool for the optimization of MEKC-MS parameters and the response surface model analysis can provide in-depth statistical understandings of the significant factors required to achieve maximum enantioresolution and ESI-MS sensitivity.
Collapse
Affiliation(s)
- Jun He
- Department of Chemistry, Center of Biotechnology and Drug Design, Georgia State University, 50 Decatur Street, Atlanta, GA 30303, USA
| | - Shahab A. Shamsi
- Department of Chemistry, Center of Biotechnology and Drug Design, Georgia State University, 50 Decatur Street, Atlanta, GA 30303, USA
| |
Collapse
|
18
|
Schappler J, Guillarme D, Rudaz S, Veuthey JL. Microemulsion electrokinetic chromatography hyphenated to atmospheric pressure photoionization mass spectrometry. Electrophoresis 2008; 29:11-9. [DOI: 10.1002/elps.200700647] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|